Loading...
RCRT-06-1360Inspection History Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Project: <NONE> Owner: Phone: (954)553 -0553 Job Address: 9710 NE 2 Avenue Miami Shores, FL 33138- Parcel: 1132060132350 Block: Lot: Scheduled Ins • # Ins • ection T 01/18/2013 INSP -18070 Final GNP Engineering Group, inc 01/10/2013 INSP- 183668 Review Building Ins • ection Status APPROVED APPROVED Ins • ector Date Com • leted Norman Bruhn 1/18/2013 Norman Bruhn 1/18/2013 CREATED AS REINSPECTION FOR INSP - 183667. Provide parking lot lighting certification. 01/04/2013 INSP- 183667 Review Building DENIED Norman Bruhn 1/4/2013 Provide parking lot lighting certification. Monday, April 1, 2013 Page 1 of 1 BUILDING RECERTIFICATION INSPECTION REPORT N PREPARED FOR: SHORES LANDING LLC PROPERTY LOCATED AT: 9710 NE 2 AVENUE MIAMI SHORES, FLORIDA P PREPARED BY: J'E.IEOT i 0 GC.,, engineering group, inc. 10400 NW 33' Street, Suite 220, Doral, Florida 33172 TELEPHONE: (305) 592 -4538 / FAX: (305) 592 -1433 • July 31, 2011 Shores Landing LLC 714 NE 59 Street Miami, FL 33137 engineering group, inc. RE: 40 -Year Recertification of Building Located at 9710 NE 2 Avenue Dear Building Official: In accordance with Section 8 -11(f) of the Code of Miami -Dade County, GNP Engineering Group, Inc. has performed an inspection of the building located at 9710 NE 2 Avenue and determined the building to be structurally and electrically safe for continued use under present occupancy. The findings of our inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification and is accompanied by a set of photos depicting the condition of the building. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent possible. Should you have any questions concerning this report, please feel free to contact us at (305) 592 -4538. Sincerely, X11 GNP Engin�eL�i� fir A*4nc. ▪ • Sz, ♦ I ") No 96 4-1 : � A _ el Par s, P.E. • Vic& -PAI�t :� o(• �' • �4 ,Lic. No. 96 �.'�Q� o• � ''•t ♦0R • I ©P•• 4ii. ,r���(i�i �N °o� Electri 1W;Ie Pla Photos R Attachments: cc: File .0111111$ `'`\,oS CCAtyo�;' ®e • i' • oo VE e' e6 �� 9 \J • V • � ® •ry ® a y No. w, s Mgrs la, P. • = _l E girieer tie: • • F` F4(;P►I 94529.�k H <': 10400 N.W. 33rd Street, Suite 220 2 Doral, Florida 33172 M Tel.: 305 -592 -4538 ® Fax: 305 -592 -1433 El Civil Engineering Structural Engineering e Construction Management • Infrastructure Assessment • Database Management • Data Collection • 40 -Year Recertification • Due Diligence • • n in PE TI PART A - STRUCTURAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: Shores Landing LLC b. Street Address: 9710 NE 2 Ave., Miami Shores, Florida c. Legal Description: 1 53 41 6 53 42 MIAMI SHORES SEC 1 AMD PB 10 -70 LOTS 3 -4 & 5 BLK 18 LOT SIZE 150 X 130 OR 23462 -2095 06 2005 1 OR 23462 -2095 0605 00 d. Owner's Name: Shores Landing LLC e. Owner's Mailing Address: 714 NE 59 St., Miami, FL 33137 -2326 f. Building Official Folio Number: 11- 3206 - 013 -2350 g. Year Built: 1946 h. Building Code Occupancy Classification: Group B Occupancy i. Present Use: Business j. General Description: One -story building, CBS construction, 13,544 SF (refer to Photos). k. Nature of Present Loading: The building has 10 businesses identified as nos. 153, 157, 159, 161, 9700, 9702, 9714, 9718, 9722 and 9726/30. 1. Additions to Original Structure: None visible. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A Page S -1 of 7 • • GNP EnAineerinA Group, Inc. INSPECTION REPORT b. Date of Actual Inspection: December 16, 2010 c. Name and Qualification of Individual Submitting Inspection Report: Angel S. Paredes, P.E. (License #44096) d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: All areas of the building were accessible at time of inspection. 3. REPAIRS: a. Structural Repair: [ X ] None Required [NIA] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify structural deficiencies and to recommend that repairs be made to the structure, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the structural deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having saterte E Page S -2 of 7 set ,Angel S • • • G 1? Gruu� a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. 4. SUPPORTING DATA a. 7 Sheets of Written Data (Part A) b. 2 Photographs (Part A & Part B) c. N/A Drawing (Plan) 5. PRESENT CONDITION OF STRUCTURE a. General Alignment: Good condition. [N /A] Bulging - None observed during inspection. [N /A] Settlement - None observed during inspection. [N /A] Deflection - None observed during inspection. [N /A] Expansion - No expansion above normal observed during inspection. [N /A] Contraction - No contraction above normal observed during inspection. b. Portions Showing Distress: None. c. Surface Conditions: Good condition. d. Cracks: Hairline sized stucco cracks. e. General Extent of Deterioration: No significant deterioration of structure observed. f. Previous Patching or Repairs: None visible. Page S -3 of 7 • • • GNP Engine- ring Group, Inc. INSPECTION REPORT 6. MASONRY BEARING WALLS a. Concrete Masonry Units: Good condition. b. Reinforced Concrete Tie Columns: Good condition. c. Reinforced Concrete Tie Beams: Good condition. d. Lintels: Good condition. e. Other Type Bond Beams: Good condition. f. Masonry Finishes (Exterior): 1) Stucco - Good condition. 2) Brick Veneer - N/A 3) Paint - Good condition. 4) Other - N/A h. Masonry Finishes (Interior): 1) Vapor Barrier - N/A 2) Furring & Plaster - Good condition. 3) Paneling — Good condition. 4) Paint — Good condition. 5) Other - N/A i. Cracks: 1) Location - No cracks observed in concrete masonry walls. Page S -4 of 7 • GNP Engineering Group, Inc. INSPECTION REPORT 2) Description - N/A j. Spalling: 1) Location - No spalling observed in concrete masonry walls. 2) Description - N/A k. Rebar Corrosion: [ X ] None Visible [N /A] Minor (patching will suffice) [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) / Description 7. FLOOR & ROOF SYSTEMS a. Roof System: 1) Description — The building has a flat roof with asphalt rolled (modified) surface supported by wood joists. 2) Heavy Equipment and Condition of Supports — HVAC equipment supports observed to be in fair condition. 3) Types of Drains /Scuppers and Condition — Gutters and downspouts observed to be in good condition. 4) General Condition - The roof surfaces were observed to be in fair condition. b. Floor System: The floor system is concrete slab. Floor coverings, furniture and stored materials prohibited a visual inspection of the entire floor surface. However, the visible areas of the floor surface were observed to be in good condition. Page S -5 of 7 • GNP Engineering Group, Inc. INSPECTION REPORT c. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random. 8. STEEL FRAMING SYSTEMS (N /A) a. Description: N/A b. Exposed Steel: N/A c. Concrete or Other Fireproofing: N/A d. Elevator Sheave Beams & Connections, and Machine Floor Beams: N/A e. Concealed Spaces Opened for Inspection: N/A f. General Condition: N/A 9. CONCRETE FRAMING SYSTEMS a. Description: CBS construction with reinforced concrete columns and beams. b. Cracking/Spalling: [ X ] Not Significant [N /A] Location and Description of Members Affected and Type c. General Condition: Good condition; no structural deficiencies were observed. d. Rebar Corrosion: [ X ] None Visible [N /A] Location and Description of Members Affected Page S -6 of 7 • GNI' Engineering Group, Inc. INSPECTION REPORT [NIA] Significant (but patching will suffice) [N /A] Significant (structural repairs required) e. Samples Chipped Out in Small Areas: [X ] No [N /A] Yes / Description f. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random. 10. WINDOWS a. Type: Aluminum frame, fixed type windows. b. Anchorage: Screws observed to be in good condition. c. Sealants: Good condition. d. Interior Seals: Good condition. e. General Condition: Good condition. 11. WOOD FRAMING a. Type: Wood joists for roof framing. b. Metal Fittings: Nailed connections observed to be in secure and in good condition. c. Joints: Joints observed to be well fitted and still closed. d. Drainage: Minor accumulation of moisture observed. e. Ventilation: Vent screens along walls. f. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random. omits, Page S -7 of 7 0� t 1$ • • • GNP Engineering Group, Inc. INSPECTION REPORT PART B - ELECTRICAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: Shores Landing LLC b. Street Address: 9710 NE 2 Ave., Miami Shores, Florida c. Legal Description: 1 53 41 6 53 42 MIAMI SHORES SEC 1 AMD PB 10 -70 LOTS 3 -4 & 5 BLK 18 LOT SIZE 150 X 130 OR 23462 -2095 06 2005 1 OR 23462 -2095 0605 00 d. Owner's Name: Shores Landing LLC e. Owner's Mailing Address: 714 NE 59 St., Miami, FL 33137-2326 f. Building Official Folio Number: 11- 3206- 013 -2350 g. Year Built: 1946 h. Building Code Occupancy Classification: Group B Occupancy i. Present Use: Business j. General Description: One -story building, CBS construction, 13,544 SF (refer to Photos). k. Nature of Present Loading: The building has 10 businesses identified as nos. 153, 157, 159, 161, 9700, 9702, 9714, 9718, 9722 and 9726/30. L Additions to Original Structure: None visible. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A b. Date of Actual Inspection: December 16, 2010 & July 30, 2011 /11011 /d/ c. Name and Qualification of Individual Submitting Inspectityi kt Qio a , ¢' Carlos M. Candelaria, P.E. (License #57984) ` C' \-\" .%9 _ No. 57984 d. Description of Any Laboratory or Other Formal TestireiTot requir. .; used Page E -1 of 6 -5yGarlosUWI aria 41,674,40...s � . • GNP Engineering Group, Inc, INSPECTION REPORT manual and visual inspection procedures. e. Accessibility for Inspection: The building was accessible at time of inspection. 3. REPAIRS: a. Electrical Repair: [ X 1 None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify electrical deficiencies in the buildings and to recommend that repairs be made to the electrical system, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the electrical deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. ®®i `i o i e d d 1, o'„ 0S CAtvo -P °-y O \ No. 57984 a. 6 Sheets of Written Data (Part B) -- ®�i: STATE OF . Q \ b. 2 Photographs (Part A & Part B) ' ® 'c �" • 9 '..9 °0 as ee cee�,\ >� c. NIA Drawing (Plan) ®,®®V!® ;1 ;4 e t 4. SUPPORTING DATA Page E -2 of 6 Carlos M. Candelaria PE #57984 July 31, 2011 'GNP Engineering Group, Inc. INSPECTION REPORT 5. ELECTRIC SERVICE • a. Estimated Size, Amperage: 1,200 Amps [ ] Fuses [ X ] Breakers • • b. Phase: [ X ] Three Phase 1 Single Phase c. Condition: [ X ] Good [ ] Fair [ ] Needs Repair d. Comments: Each unit has service entrance on west side of building. All services are single phase with exception of service for unit #9730. 6. METER AND ELECTRIC ROOMS a. Clearances: 1 1 Good [ X ] Fair [ 1 Requires Correction b. Comments: No comments. 7. GU'i l'ERS a. Location: [ X ] Good 1 1 Requires Repair b. Condition: [ X ] Good [ ] Requires Repair c. Comments: No comments. 8. ELECTRICAL PANELS a. Location: 153, 157, 159, 161, 9700, 9702, 9714, 9718, 9722 and 9726/30. b. Condition: [ X ] Good [ ] Requires Repair c. Comments: Circuit breaker panels in each unit with exception of unit no. 9700, 159 and 161 which are fed from panels "A" & "B" located in rear hallway. 9. BRANCH CIRCUITS a. Identified: [ X ] Yes b. Conductors: [ X ] Good \s canoF� y,''s [ ] No, must be idep, , d c E NSF . / • ] Deteriorated [ ] must Be Wepd Page E -3 of 6 � .arlo�gtgf a •• 4 • ,, PE #5784• mow: • /ONA GNP Engineering Group, Inc. INSPECTION REPORT c. Comments: No comments. 10. GROUNDING OF SERVICE a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 11. GROUNDING OF EQUIPMENT a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 12. SERVICE CONDUITS/RACEWAYS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 13. SERVICE CONDUCTORS & CABLES a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 14. WIRING METHODS, CABLES & CONDITION a. Types: [ X ] Conduit Raceways: [ X ] Good [N /A] Conduit PVC: [ ] Good [N /A] NM Cable: [ ] Good [N /A] EX Cable: [ ] Good Page E-4 of 6 [ ] Requires Repair [ ] Requires Repair ,`�tosea®err [ ] Rec��ri>ar��t [ ] Requires Repair ' .°9 * _ No. 57984 - : 74' *= =3-33CArlos a izt, P 984 t • • • b. Comments: No comments. 15. FEEDER CONDUCTORS a. Condition: [ X ] Good [ ] Requires Repair Comments: No comments. 16. EMERGENCY LIGHTING a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: There are emergency lights in unit nos. 157, 9700, 9702, 9714, 9722 and 9726/30 only. Other units do not have emergency lights but they are not required as per Section 39.2.9 of the NFFA 101 Life Safety Code for Existing Business Occupancies. The emergency lights should be inspected periodically as part of routine building maintenance. 17. BUILDING EGRESS ILLUMINATION a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: No comments. 18. FIRE ALARM SYSTEM (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Fire alarm system is not required as per Section 39.3.4 of the NFPA 101 Life Safety Code for Existing Business Occupancies. 19. SMOKE DETECTORS (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Refer to comments in section #18. 20. EXIT LIGHTS Page E -5 of 6 ``y t t lAE l g 1; .L � ® Vq '°�\GENS�••'Q� No. 57984 * - ;Car1 1 -£. �elaria � PE #79$d<.° x` • 4 A 1` // o • • GNP Engineering Group, Inc. INSPECTION REPORT a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: There are exit lights in unit nos. 157, 9700, 9702, 9714, 9722 and 9726/30 only. Other units do not have exit lights but they are not required as per Section 7.10.1.5 of the NFPA 101 Life Safety Code since the exit or way to reach the exit is readily apparent to the occupants. The exit lights should be inspected periodically as part of routine building maintenance. 21. EMERGENCY GENERATOR (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 22. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: No comments. 23. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING a. Condition: [ X ] Good [ ] Requires Additional [ ] None b. Comments: No comments. 24. SWIMMING POOL WIRING (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 25. WIRING TO MECHANICAL EQUIPMENT ``0 11tettt® ,®cos CANT) a. Condition: [ X ] Good [ ] Requires Repay , �`� t Ns ;. , i b. Comments: No comments. _ • No. 57984 ° m .. * Page E -6 of 6 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI -DADE COUNTY Date: July 31, 2011 Re: Case No: NIA Property Address: 9710 NE 2 Ave., Miami Shores, Florida Building Description: One -story, CBS construction, 13,544 SF The undersigned states the following: 1. I am a Florida Registered Professional Engineer or Architect with an active license. 2. On July 30, 2011, I measured the level of illumination in the parking lot(s) serving the above referenced building. 3. The level of illumination provided in the parking lot(s) meets the minimum standards for the occupancy classification of the building as established in Section 8C -3 of the Code of Miami -Dade County. .0\,‘ s P,RF'� e.i `Gl�.I.s No. .. *= (Sigbit• tuye and Se of ineer) $ • wbl Pas6efEiV E: w0": .,,SSl O N AL %% ■ �. • 9710 NE 2 Avenue, Miami Shores, Florida GNP Engineering Group, Inc. 40 -Year Recertification BUILDING RECERTIFICATION INSPECTION REPORT G N PREPARED FOR: SHORES LANDING LLC PROPERTY LOCATED AT: 9710 NE 2 AVENUE MIAMI SHORES, FLORIDA P PREPARED BY: OCT 0 7 o11 engineering group, inc. 10400 NW 33`d Street, Suite 220, Doral, Florida 33172 TELEPHONE: (305) 592 -4538 / FM: (305) 592 -1433 engineering group, inc. July 31, 2011 Shores Landing LLC 714 NE 59 Street Miami, FL 33137 RE: 40 -Year Recertification of Building Located at 9710 NE 2 Avenue Dear Building Official: In accordance with Section 8 -11(f) of the Code of Miami -Dade County, GNP Engineering Group, Inc. has performed an inspection of the building located at 9710 NE 2 Avenue and determined the building to be structurally and electrically safe for continued use under present occupancy. The findings of our inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification and is accompanied by a set of photos depicting the condition of the building. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent possible. Should you have any questions concerning this report, please feel free to contact us at (305) 592 -4538. Sincerely, GNP EnginpeY.n t, Or p .�,►>tc. ; :::4.)4.. ; No r • 96 Agsgigial :.o Ansel Par ' -s, P.E. 3� • Vic8:134 g pt - • No. aa�C d 96 10FS. t0 t..•;.\(<,:' Attachments: "64 yct t Electrical Report Photos cc: File 00 11111 •`‘` CS CAA/0'i,, No. ,( ps MS getpa, P.E ?�` .O, tec»/ical Engineer ,• tV e ' Fp.19*, • (": 10400 N.W. 33rd Street, Suite 220 M Doral. Florida 33172 ■ Tel.: 305 -592 -4538 1111 Fax: 305 - 592 -1433 MI Civil Engineering Structural Engineering M Construction Management M Infrastructure Assessment Database Management Data Collection 40 -Year Recertification Due Diligence G PART A - STRUCTURAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: Shores Landing LLC b. Street Address: 9710 NE 2 Ave., Miami Shores, Florida c. Legal Description: 1 53 41 6 53 42 MIAMI SHORES SEC 1 AMD PB 10 -70 LOTS 3 -4 & 5 BLK 18 LOT SIZE 150 X 130 OR 23462 -2095 06 2005 1 OR 23462 -2095 0605 00 d. Owner's Name: Shores Landing LLC e. Owner's Mailing Address: 714 NE 59 St., Miami, FL 33137 -2326 f. Building Official Folio Number: 11- 3206 - 013 -2350 g. Year Built: 1946 h. Building Code Occupancy Classification: Group B Occupancy i. Present Use: Business j. General Description: One -story building, CBS construction, 13,544 SF (refer to Photos). k. Nature of Present Loading: The building has 10 businesses identified as nos. 153, 157, 159, 161, 9700, 9702, 9714, 9718, 9722 and 9726/30. 1. Additions to Original Structure: None visible. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A r4( 'Angel S Page S -1 of 7 SS OW:;, ONP Eng n� eering Group Inc. INSPECTION REPORT b. Date of Actual Inspection: December 16, 2010 c. Name and Qualification of Individual Submitting Inspection Report: Angel S. Paredes, P.E. (License #44096) d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: All areas of the building were accessible at time of inspection. 3. REPAIRS: a. Structural Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify structural deficiencies and to recommend that repairs be made to the structure, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the structural deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having loot kAtRitrtl Er t% „ F t Page S -2 of 7 ',Angel S 13X:1:30•„140 S'SIOP +rjrtirti+ PE a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. 4. SUPPORTING DATA a. 7 Sheets of Written Data (Part A) b. 2 Photographs (Part A & Part B) c. N/A Drawing (Plan) 5. PRESENT CONDITION OF STRUCTURE a. General Alignment: Good condition. [N /A] Bulging - None observed during inspection. [N /A] Settlement - None observed during inspection. [N /A] Deflection - None observed during inspection. [N /A] Expansion - No expansion above normal observed during inspection. [N /A] Contraction - No contraction above normal observed during inspection. b. Portions Showing Distress: None. c. Surface Conditions: Good condition. d. Cracks: Hairline sized stucco cracks. e. General Extent of Deterioration: No significant deterioration of structure observed. f. Previous Patching or Repairs: None visible. Page S -3 of 7 “�y11111P�� r�. g'l S. Par 6. MASONRY BEARING WALLS a. Concrete Masonry Units: Good condition. b. Reinforced Concrete Tie Columns: Good condition. c. Reinforced Concrete Tie Beams: Good condition. d. Lintels: Good condition. e. Other Type Bond Beams: Good condition. f. Masonry Finishes (Exterior): 1) Stucco - Good condition. 2) Brick Veneer - N/A 3) Paint - Good condition. 4) Other - N/A h. Masonry Finishes (Interior): 1) Vapor Barrier - N/A 2) Furring & Plaster - Good condition. 3) Paneling — Good condition. 4) Paint — Good condition. 5) Other - N/A i. Cracks: 1) Location - No cracks observed in concrete masonry walls. Page S-4 of 7 ED • s +� r `"P air gel S. Par, V..a Afv.• 4 f.4 7 4. ‘ \~ 'IM O ■!' _,_ is• _in 'ua Ic 1k_ J• 2) Description - N/A Spalling: 1) Location - No spalling observed in concrete masonry walls. 2) Description - N/A k. Rebar Corrosion: [ X ] None Visible [N /A] Minor (patching will suffice) [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) / Description 7. FLOOR & ROOF SYSTEMS a. Roof System: 1) Description — The building has a flat roof with asphalt rolled (modified) surface supported by wood joists. 2) Heavy Equipment and Condition of Supports — HVAC equipment supports observed to be in fair condition. 3) Types of Drains /Scuppers and Condition — Gutters and downspouts observed to be in good condition. 4) General Condition - The roof surfaces were observed to be in fair condition. b. Floor System: The floor system is concrete slab. Floor coverings, furniture and stored materials prohibited a visual inspection of the entire floor surface. However, the visible areas of the floor surface were observed to be in good condition. Page S -5 of 7 1i1 111.1t, pp.RE ,el s. Par r. - 510 lit Fitt GNP Engineering Group, Inc. INSPECTION REPORT c. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random. 8. STEEL FRAMING SYSTEMS (N /A) a. Description: N/A b. Exposed Steel: N/A c. Concrete or Other Fireproofing: N/A d. Elevator Sheave Beams & Connections, and Machine Floor Beams: N/A e. Concealed Spaces Opened for Inspection: N/A f. General Condition: N/A 9. CONCRETE FRAMING SYSTEMS a. Description: CBS construction with reinforced concrete columns and beams. b. Cracking/Spalling: [ X ] Not Significant [N /A] Location and Description of Members Affected and Type c. General Condition: Good condition; no structural deficiencies were observed. d. Rebar Corrosion: [ X ] None Visible [N /A] Location and Description of Members Affected Page S -6 of 7 NP nginee rin g GGroun Inc. [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) e. Samples Chipped Out in Small Areas: [X ] No [N /A] Yes / Description f. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random. INSPECTION REPORT 10. WINDOWS a. Type: Aluminum frame, fixed type windows. b. Anchorage: Screws observed to be in good condition. c. Sealants: Good condition. d. Interior Seals: Good condition. e. General Condition: Good condition. 11. WOOD FRAMING a. Type: Wood joists for roof framing. b. Metal Fittings: Nailed connections observed to be in secure and in good condition. c. Joints: Joints observed to be well fitted and still closed. d. Drainage: Minor accumulation of moisture observed. e. Ventilation: Vent screens along walls. f. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random. Page S -7 of 7 GNP ngineering Group, Inc. INSPECTION REPORT PART B - ELECTRICAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: Shores Landing LLC b. Street Address: 9710 NE 2 Ave., Miami Shores, Florida c. Legal Description: 1 53 41 6 53 42 MIAMI SHORES SEC 1 AMD PB 10 -70 LOTS 3-4 & 5 BLK 18 LOT SIZE 150 X 130 OR 23462 -2095 06 2005 1 OR 23462 -2095 0605 00 d. Owner's Name: Shores Landing LLC e. Owner's Mailing Address: 714 NE 59 St., Miami, FL 33137 -2326 f. Building Official Folio Number: 11- 3206 -013 -2350 g. Year Built: 1946 h. Building Code Occupancy Classification: Group B Occupancy i. Present Use: Business j. General Description: One -story building, CBS construction, 13,544 SF (refer to Photos). k. Nature of Present Loading: The building has 10 businesses identified as nos. 153, 157, 159, 161, 9700, 9702, 9714, 9718, 9722 and 9726/30. 1. Additions to Original Structure: None visible. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A b. Date of Actual Inspection: December 16, 2010 & July 30, 2011 �'oep'ejCAN�y���� c. Name and Qualification of Individual Submitting InspectiTt ite3ao V ' ' • Carlos M. Candelaria, P.E. (License #57984) , c ..° ° No.57984 d. Description of Any Laboratory or Other Formal Testing TsTot re uir used - ..,Carlos a. gifaria; ��[cz- A. Page E -1 of 6 GNP Engineering Group, Inc. INSPECTION REPORT manual and visual inspection procedures. e. Accessibility for Inspection: The building was accessible at time of inspection. 3. REPAIRS: a. Electrical Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify electrical deficiencies in the buildings and to recommend that repairs be made to the electrical system, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the electrical deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. ,0,1101#8,,, 4. SUPPORTING DATA m %q � Q•'9 �N�o7 C . 9E6 V9P 8 9 :'::.::5----- �� 7 a. 6 Sheets of Written Data (Part B) ":"7:1:-.... STATE OF , °Qq~ b. 2 Photographs (Part A & Part B) ��*�(�••'�< R l P, • ' \w��` ®''=Sif°.NAL 5� \ *I \ ',®aaaa14I1% c. N/A Drawing (Plan) Page E -2 of 6 Carlos M. Candelaria PE #57984 July 31, 2011 GNP Enginee 'ng Group, Inc. INSPECTION REPORT 5. ELECTRIC SERVICE a. Estimated Size, Amperage: 1,200 Amps [ ] Fuses [ X ] Breakers b. Phase: [ X ] Three Phase ] Single Phase c. Condition: [ X ] Good [ ] Fair [ ] Needs Repair d. Comments: Each unit has service entrance on west side of building. All services are single phase with exception of service for unit #973 0. 6. METER AND ELECTRIC ROOMS a. Clearances: [ ] Good [ X ] Fair b. Comments: No comments. ] Requires Correction 7. GUTTERS a. Location: [ X ] Good [ ] Requires Repair b. Condition: [ X ] Good [ ] Requires Repair c. Comments: No comments. 8. ELECTRICAL PANELS a. Location: 153, 157, 159, 161, 9700, 9702, 9714, 9718, 9722 and 9726/30. b. Condition: [ X ] Good [ ] Requires Repair c. Comments: Circuit breaker panels in each unit with exception of unit no. 9700, 159 and 161 which are fed from panels "A" & `B" located in rear hallway. 9. BRANCH CIRCUITS \� \\ oS CiA�Q� psi a. Identified: [ X ] Yes [ ] No, must be idep ado G E b. Conductors: [ X ] Good [ ] Deteriorated [ ] m• ust Be ''egail: Page E -3 of 6 • i sarlo a � mow p °- PE #5784• 4 ,BONA ; \\ GNP Engineering Group, Inc. INSPECTION REPORT c. Comments: No comments. 10. GROUNDING OF SERVICE a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 11. GROUNDING OF EQUIPMENT a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 12. SERVICE CONDI I TS/RACEWAYS a. Condition: [ X1 Good [ ] Requires Repair b. Comments: No comments. 13. SERVICE CONDUCTORS & CABLES a. Condition: [ X 1 Good [ 1 Requires Repair b. Comments: No comments. 14. WIRING METHODS, CABLES & CONDITION a. Types: [ X ] Conduit Raceways: [ X ] Good [N /A] Conduit PVC: [ ] Good [N /A] NM Cable: [ ] Good [N /A] BX Cable: [ ] Good Page E-4 of 6 1 Requires Repair 1 Requires Repair ] Recte6 4� `- ++ ,\CEN8.*%19 /' ] Requires Repair • .`v . No. 57984 �i_' __ i 'i I •. • it I _ to I _..� i %itS b. Comments: No comments. 15. FEEDER CONDUCTORS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 16. EMERGENCY LIGHTING a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: There are emergency lights in unit nos. 157, 9700, 9702, 9714, 9722 and 9726/30 only. Other units do not have emergency lights but they are not required as per Section 39.2.9 of the NFPA 101 Life Safety Code for Existing Business Occupancies. The emergency lights should be inspected periodically as part of routine building maintenance. 17. BUILDING EGRESS ILLUMINATION a. Condition: [ X ] Good b. Comments: No comments. 18. FIRE ALARM SYSTEM (NIA) [ 1 Requires Repair [ ] None a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Fire alarm system is not required as per Section 39.3.4 of the NFPA 101 Life Safety Code for Existing Business Occupancies. 19. SMOKE DETECTORS (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Refer to comments in section #18. 20. EXIT LIGHTS Page E -5 of 6 B I I ItI tIPt • OS C�1NG , No. 57984 Carley r ;; elaria' c 0 p PE #379 'I, % ° a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: There are exit lights in unit nos. 157, 9700, 9702, 9714, 9722 and 9726/30 only. Other units do not have exit lights but they are not required as per Section 7.10.1.5 of the NFPA 101 Life Safety Code since the exit or way to reach the exit is readily apparent to the occupants. The exit lights should be inspected periodically as part of routine building maintenance. 21. EMERGENCY GENERATOR (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 22. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: No comments. 23. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING a. Condition: [ X ] Good [ ] Requires Additional [ ] None b. Comments: No comments. 24. SWIMMING POOL WIRING (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 25. WIRING TO MECHANICAL EQUIPMENT 0,0111111,, .•S OS CANjJ'e a. Condition: [ X ] Good [ ] Requires Repai®� •' °' ..1, b. Comments: No comments. _ • - • No. 57984 ---13-6-• •,Ca os m. C Fdela Q ..,; , < 0 RED 7 oe ee Page E -6 of 6 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION, STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI -DADE COUNTY Date: July 31, 2011 Re: Case No: N/A Property Address: 9710 NE 2 Ave., Miami Shores, Florida Building Description: One - story, CBS construction, 13,544 SF The undersigned states the following: 1. I am a Florida Registered Professional Engineer or Architect with an active license. 2. On July 30, 2011, I measured the level of illumination in the parking lot(s) serving the above referenced building. 3. The level of illumination provided in the parking lot(s) meets the minimum standards for the occupancy classification of the building as established in Section 8C -3 of the Code of Miami -Dade County. s P'R ' ��C�,\ S S'. G No (Sigbiture'and Se ineer) F '�,SS�ONA\-: 0 9710 NE 2 Avenue, Miami Shores, Florida GNP Engineering Group, Inc. 40 -Year Recertification z(„9 11142r AJ e canes.. co M (.» -cD 3c`f - (Mr Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. (P` I V 5C) Master Permit No. BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING � ROOFIN FIN �— (OWNER: Name (Fee Simple Titleholder): 1)71 ('e k. t( t APR 2 9 2011 (-6---1 I Address: s 53 TCity: �^'t` Phone#: ✓ 1 124( State: Tenant/Lessee Name: l: J Phone #: �1Email: ;> Zip: 33 (3P 74JOB ADDRESS: * v cc Cf) -4-e- - City: Miami Shores County: Miami Dade Zip: f b Folio/Parcel #: Is the Building Historically Designated: Yes )'CONTRACTOR: Company Name: 0Q/ r U0 2-_ Address: City: State: Zip: Qualifier Name: \ Phone# State Certification or Registration #: Certificate of Competency #: Contact Phone #: Email Address: DESIGNER: Architect/Engineer: Phone #: - NO Flood Zone: Phone#: Value of Work for this Permit: $ E J 0 Square/Linear Foo gespf q : Type of Work: ❑Addition OAlteration ONew URepair/Replace ODemolition Description of Work: [°O 1 cicCty cL / wc( `s **** *******************+ x***+ x* ***x:*** ***Fees+x*** ** * * ** :*+ x**+ x***** ** *****x:*******:x ******m Submittal Fee $ J`- '��`� Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOTI.RRS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR , LET Eft R AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCE N Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection ill not be a,' roved and a reinspection fee will be charged. Signature L Signature Ownerroo Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of :LtL -, 20 111/4, by Lt[-- S _ p k i+Jl1lday of , 20 _, by who is personally known to me or who /Ihas-prorkca. , whb is personally known to me or who has produced As identification and who did take an -oath. J J _ as identification and who did take an oath. NOTARY PUBLIC: oi II lit! Sign: 'tti Oj ; ' a - ® °� es _ Print: _ -�, - ..., ®, -� ; _ T• .." w -® N .'' . ' ************ x�x� :x ****m�u******* *****�x+x�xx� ** ** * *** x********* * ********** ** x**** *** *********** ******** My Commission Expires: F- �1�1OtARY P BLIC: Sign: Print: My Commission Expires: APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) roN # :AP1061659 IT #:13 -SC- 1392771 NT #:F1861929 PAID: 02/13/2012 PAID :200.00 7PT #:13 -PID- 1814150 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [01] TANK SIZE [1] 900.00 [02] TANK MATERIAL [2] [03] OUTLET DEVICE Polyethylene [04] MULTI- CHAMBERED [05] OUTLET FILTER [06] LEGEND 1. 70 -970 1 - 9DC3 2. [ ] [07] WATERTIGHT [ ] [08] LEVEL [ ] [09] DEPTH TO LID DRAINFIELD INSTALLATION [ ] [10] AREA [1] 240 [2] [ ] [11] DISTRIBUTION BOX [ ] [12] NUMBER OF DRAINLINES [ ] [13] DRAINLINE SEPARATION [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER [ ] [16] ELEVATION [ ABOVE [ ] [17] SYSTEM LOCATION [ ] [18] DOSING PUMPS [ ] [19] AGGREGATE SIZE [ ] [20] AGGREGATE EXCESSIVE FINES [ 7 [21] AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH [ ] [25] AREA REPLACED [ ] [26] REPLACEMENT MATERIAL Comments: Polylok N ] CONSTRUCTION DISAPPROVED l: FINAL SYSTEM [ �DDDnen. / DISAPPROVED ]: (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E- 6.003, FAC EH Database v 1.0.1 SQFT HEADER X. 1. 4.00 2. BM 38.64 SETBACKS [ ] [27] SURFACE WATER [ 7 [28] DITCHES [ ] [29] PRIVATE WELLS [ ] [30] PUBLIC WELLS [ ] [31] IRRIGATION WELLS [ 7 [32] POTABLE WATER [ ] [33] BUILDING. FOUNDATIONS [ ] [34] PROPERTY LINES [ ] [35] QTHER FILLED / MOUND SYSTEM [ ] [36] DRAINFIELD COVER [ ] [37] SHOULDERS [ 1 [38] SLOPES [ ] [39] STABILIZATION [ [ ] ADDITIONAL INFORMATION [40] UNOBSTRUCTED AREA [41] STORMWATER RUNOFF [42] ALARMS [43] MAINTENANCE AGREEMENT [44] BUILDING AREA [45] LOCATION CONFORMS WITH [46] FINAL SITE GRADING [47] CONTRACTOR Roberto Rodriguez (Southern [48] OTHER ABANDONMENT [49] TANK PUMPED 02/17/2012 [50] TANK CRUSHED & FILLED 15 12 7 15pool SITE PLAN ADS ARC 24 Ronald E Cave (Dade County Environmental Health) ona • ave • a . e • un nvIronmenta eat s AP1061659 EID1392771 Dade cab Dade CHD 02/17/2012 DATE: 02/17/2012 DATE: 02/17/2012 Page 2 of 3 FT FT FT FT FT FT FT FT FT tarsti cL-S: ItoteJ l/ 10050 N. E. 2N1D AVENUE F L O R 1 D A 33138 1 v 1 111111 11 1 I 1111 Pro41 nasmrai-EFT2W1401 Shores Landings LLC 714 NE 59th St Miami, Fl 33137 UNITED STATES POSTAL SERVICE. First-Class Mail' Postage & Fees Pald USPS Permit No. G-10 • Sender. Please print your name, address, and ZIP +4 in this box • MIAMI SHORES VILLAGE 10050 N. E. 2nd AVENUE MIAMI SHORES, FL 33138 SENDER: COMPLETE THIS SECTION COMPLETE THIS SECTION ON DELIVERY • Complete items 1, 2, and 3. Also complete item 4 if Restricted Delivery is desired. s Print your name and address on the reverse so that we can return the card to you. • Attach this card to the back of the maiipiece, or on the front if space permits. 1. Article Addressed to: Shores Landings LLC 714 NE 59th St Miami, Fl 33137 A. Signature X B. Received by (Printed Name) 0 Agent 0 Addressee C. Date of Delivery D. Is delivery address different from item 1? 0 Yes if YES, enter delivery address below: 0 No Se ce Type Certified Mail 0 Registered 0 insured Mall 0 Express Mall 0 Retum Receipt for Merchandise 0 C.O.D. 4. Restricted Delivery? (Extra Fee) 0 Yes 2. Article Number (Transfer from service !abe° 7004 1350 0002 6362 1244 PS Form 381.1, February 2004 Domestic Return Receipt 102595 -02 -M -1540 MIAMI SHORES VILLAGE Building Department 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305- 795 -2204- Fax: 305- 756 -8972 1/30/2007 Permit No. RCRT -5 -06 -1360 Certified Mail # 7004 1350 0002 6362 1244 Shores Landings LLC 714 NE 59th St Miami, Fl 33137 Re: Mandatory 40 Year Re- Certification for Property at: Address: 9710 NE 2 Avenue City: Miami Shores Village State: Florida, Zip: 33138 Notice of Required Inspection /Certification is Still Delinquent Dear Owner, The Village has been notified by Miami -Dade Building & Zoning Department that the above . referenced property has a building or structure that requires recertification. Miami -Dade County Chapter 8 Section 8 -11 requires all existing buildings and structures to be recertified at age forty (40) and then subsequently at ten (10) year intervals. Within ninety (90) days of receiving the Notice of Required Inspection /Certification, the owner of the building or structure subject to recertification is required to furnish to the Building Official a written report prepared by a Professional Architect or. Engineer certifying that each building or structure is structurally and electrically safe, or has been made structurally and electrically safe. THE NOTICE OF REQUIRED INSPECTION /CERTIFICATION WAS MAILED RETURN RECEIPT REQUESTED AND SIGNED FOR ON MARCH 9, 2006 OVER TWO - HUNDRED -FIFTY (250) DAYS AGO. We look forward to your cooperation in this matter by responding within 21 days from date of receipt of this letter; however failure to comply will leave us no alternative to proceed by declaring the structure unsafe and notifying the Miami - Dade County Unsafe Structure Board for action as previously stated. By the provisions of Miami -Dade County Chapter 8 Section 5, you are responsible for all Unsafe Structure's enforcement costs, including appellate costs incurred by Miami Shores Village. The property will be subject to a lien for those costs if payment is not made upon request of the department. Please file the above referenced report at the Miami Shores Building Department at Village Hall accompanied with a $250.00 filing fee plus $100.00 late fee for a total of $350.00 dollars. Sincerely, Clau io Grande, Building Official 305- 795 -2204 i4I,U S'Ait ef?" 10050 N. E. 2NO AVENUE FLORIDA 3313S 'YE sum.- 77Z. y flowt,74-ii4t=n 971 2 AV I S ':S,F CO, 221210X2802 38 NIXIE LIJW • 1 t !J 12 :0 33 1 07 02/14/07 RETURN TO SENDER NO SUCH NUMBER UNABLE TO FORWARD BC: 23126220299 *130B-073SO-20-41 MIAMI SHORES VILLAGE Building Department 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305- 795 -2204• Fax: 305- 756 -8972 1/30/2007 Permit No. RCRT -5 -06 -1360 Certified Mail # 7004 1350 0002 6362 1244 Shores Landings LLC 714 NE 59th St Miami, F133137 Re: Mandatory 40 Year Re- Certification for Property at: Address: 9710 NE 2 Avenue City: Miami Shores Village State: Florida, Zip: 33138 Notice of Required Inspection /Certification is Still Delinquent Dear Owner, The Village has been notified by Miami -Dade Building & Zoning Department that the above referenced property has a building or structure that requires recertification. Miami -Dade County Chapter 8 Section 8 -11 requires all existing buildings and structures to be recertified at age forty (40) and then subsequently at ten (10) year intervals. Within ninety (90) days of receiving the Notice of Required Inspection /Certification, the owner of the building or structure subject to recertification is required to furnish to the Building Official a written report prepared by a Professional Architect or Engineer certifying that each building or structure is structurally and electrically safe, or has been made structurally and electrically safe. 7004 1350 0002 6362 1244 a U.S. Postal ServiceTM,`_ -14 CERTIFIED MAID RECEIPT. (Domestic Mail Only; No Insurance Coverage, Provided) For delivery information visit our website atwww.usps.como Postage Certlfled Fes Return Reelect Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Total Postage & Fees $ 4 - (nct. Postmark Here 3 0 2007 ° AIL OE So( Iltreet Apt Na, orPOBoxNo. PS Form 3800;;June 2002 See Reverse for Instructions THE NOTICE OF REQUIRED INSPECTION /CERTIFICATION WAS MAILED RETURN RECEIPT REQUESTED AND SIGNED FOR ON MARCH 9, 2006 OVER TWO - HUNDRED -FIFTY (250) DAYS AGO. We look forward to your cooperation in this matter by responding within 21 days from date of receipt of this letter; however failure to comply will leave us no alternative to proceed by declaring the structure unsafe and notifying the Miami - Dade County Unsafe Structure Board for action as previously stated. By the provisions of Miami -Dade County Chapter 8 Section 5, you are responsible for all Unsafe Structure's enforcement costs, including appellate costs incurred by Miami Shores Village. The property will be subject to a lien for those costs if payment is not made upon request of the department. Please file the above referenced report at the Miami Shores Building Department at Village Hall accompanied with a $250.00 filing fee plus $100.00 late fee for a total of $350.00 dollars. Sincerely, Claudio Grande, Building Oft ial 305- 795 -2204 SENDER: COMPLETE THIS SECTION ■ "tomplete items 1, 2, and 3. Also complete Item 4 if Restricted Delivery is desired. 0 • Print your name'and address on the reverse so that we can return the card to you. • Attach thls card to the back of the mafpiece, I or on the front if space permits. 1. Article Addressed to: Shores, Landings LLC 714NE59thSt Miami, Fl 33137 -2326 2. Article Number (Transfer from service PS Form 3811, February 2004 COMPLETE THIS SECTION ON DELIVERY A. Signature X 0 Agent: 0 Addressee B. Rene . by ( Print N y =) C. Date of Delivery D. ..0 0 C.O.D. 4. Restricted Deilvery? (Extra Fee) 7005 0390 0003 8152 2003 Domestic Retum Receipt Merchandise 0 Yes 102595-02-M-1540 UNITED- STAT POSTAL SERVICE �I' • Sender Please iitint your name, address,, and Z '" ;`i is box •" MIAMI SHORES VILLAGE 10050 N. E. 2nd AVENUE MIAMI SHORES, FL 33138 to-A5 i, • Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2207 Fax: (305) 756.8972 Building Department February 28, 2006 Shores Landings LLC 714 NE 59th St Miami, F133137 -2326 Certified Mail # 7005 0390 0003 8152 2003 Re: Mandatory 40 Year Re- Certification for Property at: 9710 NE 2nd Ave Miami Shores, FL 33138 Folio # 11- 3206 -013 -2350 Notice of Required Inspection/Certification Dear Owner: The Village has been notified by Metro -Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8 -11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two- hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection/Certification. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305- 795 -2204. Sincerely, Claudio Grande, Building Official 305- 795 -2204 7005 0390 01303. 8152 2,003 US . Postal Service., C,ERTIFIED MAILTM RECEIPT (Uornestrc Mail Only No lns ante Coverage Provided) For delivery information visit our website at www.usps.como Postage Certified Fee Return Receipt Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Total Postage & Fees $4•G4 lark H Sor e . S CANO N c i , or PO B NN -14 Nv 5q 0- Cny, state, 4Pe i' IV e PS Form 3800rulge 2002 41, See e verse or Instn etio s`