Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-12-754
s Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC20Lcq Permit Type: MECHANICAL fii)MOZEWM`) 2°tI 12 BY:._. Permit No. rink 1 2-151 Master Permit No. OWNER: Name (Fee Simple Titleholder): /3 (,4j �y;\re.e . +� .. Phone#: Address: City: State: Tap: Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: 11300 N.E. 2nd Avenue t ActX) fit— K N 0(: City: Miami Shores County: Miami Dade Zip: 33161 Folio/Parcel #: Is the Building Historically Designated: Yes NO X Flood Zone: CONTRACTOR: Company Name: Cool Water Air Conditioning Inc. Address: 760 South Shore Drive Phone#: 305 - 807 -0288 City: Miami Beach Qualifier Name: Stephen Kerney State Certification or Registration #: CIVIC 056710 Certificate of Competency #: CMC 056710 State: Florida Zip: 33141 Phone#: 305- 807 -0288 Contact Phone#: 305 - 807 -0288 Email Address: steve@coolwaterac.com DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 22,141.00 Square/Linear Footage of Work: Type of Work: °Address °Alteration °New ElRepair/Replace Description of Work: Replace existing 20 ton split sytem °Demolition * * * * * * ** ** 4 Submittal Fee $ - ..;_ 64 Permit Fee $ oO CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL }EE NOW DUE $ l_YD 1.�j'i.C1. k\:--(0 'Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT.RCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approvey, nd a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this 0 9. day of /�'f%� , 20 /Z , by i'__._- who is personally known to me or who has produced Signature The foregoing nstrument was acknowledged before me this Ito Contractor day of L— , 20 It; by STrafire,kr 16, who is personally known to me or who has produced I D As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Ex Notary Public State of Florida Cheryl Beide Gerber My Commiss on D0966126 Expires 05/08/2014 * ***+k***** **** k *Ne****ai****xal4k** APPROVED BY NOTARY PUBLIC: Sign: Print: My Commission Expires: ll3 3 .0 sI "1180d akyam * • ,,. , , kph+ F* �H�N+ k* onH�A�aoae�k+ k�k�fasffiH+, kxe�# N�o ls�s�k *sN�k�k�sH��kIX�m�+tl�ra,i ** **�kae�h* �k *A�+k�k****** v Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06/10/2009)(Revised 3/15/09) Zoning Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): i 1 -3 CS ca Air £ P Zed A tie—. City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO ERHI Sheet Attached: YES ❑ NO U./Contract Attached: YES UNIT BEING REPLACED DATA NEW UNIT Carr -; c v- MANUFACTURER -TVA ,k\ ss :..., ,s4ost_pL4 -e AHU or PKG. UNIT MODEL # 7- u, E '1-4{.0 e. 4.004 3C A0 °' 02-/V" 6 3C2 COND. UNIT MODEL # °r-rA -z 't el a 4ot, A co KW HEAT to o NOM TONS Ica AHU CU PKG 1) M.C.A AHU 2MCUSf'7 PKG AHU CU PKG 2) M.O.P AHU 3;a CU(® PKG AHU CU PKG 3) VOLTS AHU YCcCU °/do PKG PKG UNIT / / PKG UNIT / / EER/SEER YES NO REPLACING DUCTS YES NO w° YES NO REPLACING THERMOSTAT YES ✓ NO YES NO NEW 4 °CONCRETE SLAB YES NO ../ YES NO NEW ROOF STAND YES NO ✓°.--- YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 'o 3. Voltage of Circuit (208/240/480): k g 0 4. Size Disconnecting Means: / d 0 Contractor's Company Name: ®0 ( kV& +r - �v 4 ; v., . Phone: o z S' 8 State Certificate or Registration N. Cele, 05-6 °1 `cc Certificate of Competency N. 6 Signature Date: — 2 _ 6 ) — 2 _ ACC7RC7' COOLWAT -01 JOSH CERTIFICATE OF LIABILITY INSURANCE DATE (MMIDDIYYYY) 4120/2012 PRODUCER Automatic Data Processing Insurance Agency, Inc 1 ADP Boulevard Roseland, NJ 07068 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAIC # INSURED Cool Water Air Conditioning Inc. 760 South Shore Drive Miami Beach, FL 33141 INSURER A: BEIC - Bridgefield Employers I INSURER B: INSURER C: INSURER D: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR ADD'L NSRD TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE DATE IMMSDD$Yi YY) POLICY EXPIRATION DATE NAMIDDM'YYI LIMITS GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGETO REN I ED PREMISES (Ea occurence) $ CLAIMS MADE OCCUR MED EXP (My one person) $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ GENII. AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $ 7 POLICY PRO- - LOC AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ GARAGE LIABILITY ANY AUTO AUTO ONLY - EA ACCIDENT $ OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESS I UMBRELLA LIABILITY OCCUR n CLAIMS MADE DEDUCTIBLE RETENTION $ EACH OCCURRENCE $ AGGREGATE $ $ $ $ A WORKERS AND EMPLOYERS' ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICERIMEMBER (Mandatory If yes, describe SPECIAL PROVISIONS COMPENSATION LIABILITY Y / N 0830-49665 1212512011 12/25/2012 X WC STATU- OTH- TORY LIMITS ER E.L. EACH ACCIDENT $ 1,000,000 EXCLUDED? Y E.L. DISEASE - EA EMPLOYEE $ 1,000,000 In NH) under below E.L. DISEASE - POLICY LIMIT $ 1,000,000 OTHER DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT I SPECIAL PROVISIONS CERTIFICATE HOLDER Miami Shores Village 10050 NE 2nd Avenue Miami Shores, FL 33138- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ACORD 25 (2009101) 01988 -2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD ..' CERTIFICATE OF LIABILITY INSURANCE DATEIMMID°, 04/24!12 THIS CERTIFICATE I8 ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT. If the cettlacete holder k an ILL,. INSURED, the poi Ise) must be endorsed. It SUBROGATION 1S WANED, $ UbJSGt tQ the terms and conditions of the poky, certain potholes may require an endorsement A statement on this c rttncate does not confer dghta to tyre certlftcate holder in Wu each endomement(s). PRODUCER Alexander and Grweep Insurance 2727 E. Oakland Park Blvd. Ste 200 Ft. Lauderdale, FL 33306 Phone 954) 581 -9498 Fax 954 551 -1350 ACl' 4 : (964) 681 -8496 1 rfi. Nok (954) 581 -1350 , ,, - staveaelexandergreep.00m Ii AFFORDING COVERAGE d RERA: Waco Insurance Company N INSURED Cool Water Air Conditioning, Inc. 760 South Shore Drive Miami Beach, FL 33141 954 ww.n+w a wow ----- _ -- --- - -- - -- INSURER B : $ 100•000•00 INSURER C : MED �' (Any one parson) INSURER 0 : PERSONAL & ADV INJURY ASSURER E ❑ INSURER F : $ 2,000,000.00 • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDTnONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PJD CLAIMS. eta LR.._ A TYPE OF INSURANCE RASRW p POLICY NUMBER 0198287 ItA1MiDWYYYYI 04!1412012 tA1011D NtNYYYY! 04/14/2013 LBWS EEACH� C $ 1,000,000.00 GENERAL LI M TY ;i COMrMERCIAL GENERAL LIABILITY N DAMat E TOE occurrence) $ 100•000•00 ❑ ❑ CLAMS DE ® OCCUR ❑ MED �' (Any one parson) $ 5,000.00 PERSONAL & ADV INJURY 8 1,000,000.00 ❑ GENERAL AGGREGATE $ 2,000,000.00 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS -COMP/OP AGG $ 2,000,000.00 ® .POLICY • IFg • LOC $ AUTOMOBa.E LIABILITY ❑ ANY AUTO • AUTOS O ❑ AUTOS �tSINGLE tJMIT a BODILY INJURY (Per person) $ BODILY INJURY (Per accidenti $ II HIRED AUTOS ❑ os ED plop �r ) 8 ED $ • t eRELLA LIAe ■ OCCUR • EACH OCCURRENCE $ ❑ EWES* 1•1$13 ❑ CLAIMS -MADE AGGREGATE $ ❑ DED ❑ RETENTION$ $ woRKERSODWIENSATION ANDEMPLOYE/ ' UASILRY Y 1 N ANY PROiRtIETOR/P.ARTNERlEXECUfwVE OFFICERBER EXCLUDED? ❑ Mandatory In 101) OESGIRIPTION OF PO ERATtONS ter NIA WC STATU- ❑ 1-1 OTH- ❑ TORY LMfW ER EL EACH ACCIDENT $ E.L DISEASE - EA EMPLOYEE $ E.L DISEASE - POLICY LIMIT $ DE$CMP7ION OF OPERATIONS r LOCATIONS MENICLES (Attach ACORD 101, AddMenal Reeks Schedtde, R more apace is numbed) Miami shores Village 10050 NE 2 Ave Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORBED REPRESENTATIVE "1.7111 17Z_ ACORD 26 (2010106) OF ®1988 -2010 ACORD CORPORATION. All fights reserved. The ACORD name and logo ere registered marks of ACORD COOL WATER AIR CONDITIONING INC. 760 South Shore Drive Miami Beach F133141 Phone 305 807 -0288 Fax 305- 865 -0800 www.coolwaterac.com Barry University 11300 NE Second Avenue Miami Shores, Florida 33161 Attn: Ron Hultquest / Jeffrey Yao RE: Wiegand Annex 20 Ton Split System The following proposal is to replace the (20) ton split system. Scope of work: April 2, 2012 A Disconnect remove and properly dispose of existing Carrier split system. • Provide and install (1) new (20) ton American Standard split system equip with 10KW strip heat. > Provide and install new supply air ductwork transition and insulate. > Reconnect condensate line, electric and controls. > Replace necessary suction line insulation. > Leak -check all connections. > Evacuate system charge with refrigerant. > Start -up unit and check for proper operation. Note: All work to be performed during normal business hours, 8:00 am to 5:00 pm Monday through Friday This price will include: all material, labor, crane fees, permitting and applicable sales tax. Our price for this scope of work will be --- --------- - - - - -- $ 22,141.00 Sincerely, Lorn Tucker Payments to be made as follows: 35% deposit with the balance due upon completion TERMS AND CONDITIONS OF THIS CONTRACT: It is expressly understood and agreed that Cool Water Air Conditioning Inc. retains title to the above- described property. In addition, it shall not pass or become vested in the purchaser until the entire purchase price has been paid. Said property shall be and remain personal property and retain its character as such and purchaser shall not attswh or affix said property to any realty so that it does not lose its character as personal property nor shall purchaser resell said property until the full purchase price thereof has been paid. The purchase price shall be due and payable as provided under "terms" above. Finance charges will be applied to all late payments. Upon the failure of the purchaser to make any payments on the due date, the seller, at its option, may declare the entire balance of the purchase price due and payable. In case of default, purchaser shall pay all costs and damages including a reasonable attorney's fee incurred by seller in collecting this account or repossessing the described property, whether suit be brought or not. Purchaser hereby waives presentments, demand, and all other pre- requisites required to make it liable. No warranties, representations, or promises not appearing in writing in this contract shall be recognized. This agreement shall not be considered executed or binding to the seller until duly accepted by an authorized officer of the seller. The execution by seller of this agreement is subject to force majeure and its contingent upon strikes, accidents, acts of God, weather conditions, regulations, or other restrictions imposed by any Government or Governmental agency or other delays beyond seller's control. All work to be performed during normal working hours Monday through Friday 8: 00 am to 5:00 pm. unless otherwise specified. Excludes any code upgrades on existing equipment. All quotes are good for 30 days from date. Authorized Signature Date PO Customer: Project: Model Number:1TA180E -240E Dimensional Data Figure 28.15 -20 Ton Condensing Unit, Dual Compressor HALL GUARD (OPTIONAL) NOTES: 1.MINIMUM CLEARANCE FOR PROPER OPERATION IS 38" FROM WALLS. SHRUBBERY. PRIVACY FENCES ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS 4R 7T. RECOMMENDED SERVICE CLEARANCE 48" 2TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100" MIMING UNIT SHOULD BE PLACED SO ROOF RUN OFF WATER DOES NOT POUR DIRECTLY ON UNIT 3.OUTDOOR AI i TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING) HAIL GUARD (OPTIONAL) -48- WITH HAIL GUARD 44" FRONT DETAIL A DIMENSIONAL DETAIL SS- PRCO28 -EN 89 ahridirectory;,org4 Certificate of Product Ratings AHRI Certified Reference Number: 3545372 Date: 4/20/2012 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Model Number: TTA240E4"*A* Indoor Model Number: TWE240E4**B* Manufacturer: AMERICAN STANDARD, INC. Trade/Brand name: AMERICAN - STANDARD tStatus: Active Rated as follows in accordance with AHRI Standard 340 /360 -2007, Commercial and Industry Unitary Air- Conditioning and Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 254000 EER Rating (Cooling): 10.00 IEER: 10.9 Heating Capacity at 47F (Btuh): COP at 47F: Heating Capacity at 17F (Btuh): COP at 17F: t Models with an 'Active' status are those that are currently In production. Models with a 'Discontinued' status are those that the manufacturer has elected to stop producing, yet stock is still available. Models with an 'Obsolete' status are those that the manufacturer is required to stop manufacturing due to an AHRI certification program test failure- * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assianes no responsibility for, the product(s) listed on this Certificate. AHRI expressly discerns all Ilabitity for damages of any Idnd arising out of the use or perlonmance of the product(s), orthe rmauthorlzed alteration of data limed on thls Certificate. Certified ratings are valid only for models and configurations fisted in the directory at www.ahridirectoiy.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual, personal and confklentlal reference purposes. The contents of this Certificate may not hi whole win part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, M any form or manner or by any means, except forthe user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The Infomratian forte model cited on this Certificate can he verified at vrww.ahridirectory.org, ® Air - Conditioning, Heating. dick on "Venfv Certificate" Mk and enter the AHRI CeitMed Reference Number and the date on rem am I® and Refrigeration institute which the certificate was issued, which Is Listed above, and the Certificate No, which Is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129794224824926780 MC., -`1S i Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS OUTSIDE AIR CALCUALTIONS FOR: BARRY UNIVERSITY - WIEGAND ANNEX 11300 NE 2ND AVENUE MIAMI SHORES AC UNIT OUTSIDE AIR CALCULATIONS SPLIT SYSTEM FRESH AIR REQUIREMENTS FOR CLASSROOMS AS PER FBC TABLE M403.3 FRESH AIR = 7.5 CFM / PERSON PLUS 0.06 CFM / SF, 65 PEOPLE / 1,000 SF DEFAULT OCCUPANT DENSITY TOTAL CLASSROOM SPACE: 4,497 SF CALCULATIONS: (DENSITY) 4,497 SF / 1,000 x 65 = 292 PEOPLE 292 PEOPLE x 7.5 CFM + 4,497 SF x 0.06 CFM / SF = 2,460 CFM FOR CLASSROOMS FRESH AIR REQUIREMENTS FOR SCIENCE LABS AS PER FBC TABLE M403.3 FRESH AIR = 10 CFM / PERSON PLUS 0.18 CFM / SF, 20 PEOPLE / 1,000 SF DEFAULT OCCUPANT DENSITY TOTAL SCIENCE LABS SPACE: 2,545 SF CALCULATIONS: (DENSITY) 2,545 SF / 1,000 x 20 = 51 PEOPLE 51 PEOPLE x 10 CFM + 2,545 SF x 0.18 CFM / SF = 968 CFM FOR SCIENCE LABS CFM TOTALS: 2,460 CFMS (CLASSROOMS) + 968 CFM (SCIENCE LABS) = 3,428 CFM REQUIRED: 3,428 CFM SUPPLIED: 3,428 CFM gECEIVEID APR 2 7 2012 1798 NW 39 COURT . OAKLAND PARK, FL 33309 Tel: (954) 295 -2182 Fax: (954) 733 -5622 rr righ Right - Suite® Universal 2012 Short Form Wiegand Job: Date: 4/26/12 By: RCS Project Information For: Barry University - Wiegand Annex 11300 NE 2nd Avenue, Miami Shores, FL db Outside RH Outside wb Daily range Moisture diff. ( °F) ( %) ( °F) ( °F) (gr/Ib) Htg 48 CIg 89 59 77 10 56 Heating Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Leaving Air Temp Actual Heating Fan American Standard 10 kW Elec furnace 100 AFUE 34.1 34.1 59.6 73.9 8000 MBtuh MBtuh gpd °F cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Inside db Inside RH Inside wb Design TD ( °F) ( %) ( °F) ( °F) Htg CIg 70 75 50 63 22 14 Cooling Equipment Make Model Type COP /EER /SEER Sensible Cooling Latent Cooling Total Cooling Leaving Air Temp Actual Cooling Fan Wiegand PEAKCV PACKAGE 0 0 American Standard TTA240E4**A* Split AC 10.0 181.4 73.7 255.1 55.0 8000 in H2O MBtuh MBtuh MBtuh °F cfm NAME 1 Area ft2 Heat Loss Sensible Gain I Latent Gain Htg cfm CIg cfm Time Annex 10000 45297 180167 59572 8000 8000 Jul 1800 LDT Wiegand ! 10000 45297 180167 59572 1 8000 8000 Jul 1800 LDT weigh wrightsoft Right - Suttee Universal 2012 12.0.04 RS000484 Lom Tucker\Wlegand Annex 4-26- 121Chemistry Research Lab.rup Calc = RTS Building faces: N wright oft Right - Suite® Universal 2012 Load Summary o te: 4126/12 Annex By: RCS Project Information] one: Ann For: Barry University - Wiegand Annex 11300 NE 2nd Avenue, Miami Shores, FL °QLIk 1. DESIGN CONDITIONS at Jul 1800 LDT Peak load at Jul 1800 LDT Inside: 75 °F Outside: 89 °F TD: 14 °F RH: 59 % MoistDiff: 56.5 gr/lb Mult: 1.0 Ins.wb 63 °F 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 27695 Glass: -953 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 10062 4. INTERNAL HEAT GAIN Sensible Latent 137874 72055 Occupants: 83225 72055 Lights: 54649 Motors: 0 - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space Toad Sensible Latent 187329 72055 Envelope 187329 72055 Less external 0 - Redistribution 0 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 8000 at supply TD: 20 9. VENTILATION: Make -up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Sensible Latent 12652 36803 b 0 187329 3428 7163 0 0 180167 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 °F Outside: 48 °F TD: 22 °F 14. TRANSMISSION LOSSES 10136 Walls: 6652 Glass: 1002 Doors: 0 Partitions: 0 Floors: 833 Ceilings: 1649 - 15. INFILTRATION: Outside air cfm: 600 1979 16. SUBTOTAL: Space load 12116 Envelope 12116 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 0 18. VENTILATION: Make -up air cfm: 3428 11310 19. HUMIDIFICATION 21872 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 45297 12483 59572 201,2 - Apr - 2614:1: wdghts' Right- Suite® Universal 2012 12.0.04 RSU00484 Pa Lom Tucker\Wlegand Annex 4 -26-12 \Chemistry Research Lab.rup Calc = RTS Building faces: N 2 a. Ih Right- Suite® Universal 2012 Load Calculatior�°b ate: 4/26/12 Annex By: RCS Project Information For: Barry University - Wiegand Annex 11300 NE 2nd Avenue, Miami Shores, FL LWH: 10000 x 1.0 x 12.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference ( Jul 1800 LDT ) Dry Blb RH Moisture Range Wet Blb 89 59 10 77 75 50 63 0 14 56.5 [ Mult = 1.0 ] - 2. GLAZING SOLAR HEAT GAIN (Lat = 25.78 °N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMuIt SC Sens /A Sens GLAZ -01 n 47 90 0.81 n 1.00 0.72 21.5 1004 GLAZ -02 n 69 90 0.40 n 1.00 0.72 22.7 1575 GLAZ -03 e 104 90 shd n 1.00 0.72 32.0 3325 GLAZ -04 s 8 90 shd n 1.00 0.72 19.8 159 GLAZ -05 s 56 90 shd n 1.00 0.72 19.8 1111 GLAZ -06 w 64 90 0.00 n 1.00 0.72 85.6 5478 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Sol-air TD Shad CIr ConvSens RadSens Sens GLAZ -01 n 47 47 0.960 12.8 N - 212 907 876 GLAZ -02 n 69 69 0.960 12.8 N - 315 1432 1385 GLAZ -03 e 104 104 0.960 12.8 N 473 3110 3040 GLAZ -04 s 8 8 0.960 12.8 N 36 142 137 GLAZ -05 s 56 56 0.960 12.8 N 255 995 958 GLAZ -06 w 64 64 0.960 12.8 N - 291 5346 5303 WALL -01 n 1434 1318 0.426 17.5 N m 1978 1617 3596 WALL -02 e 1668 1564 0.426 5.7 N m 4741 7971 12712 WALL -03 s 1482 1418 0.426 6.0 N m 2498 1906 4404 WALL -04 w 966 902 0.426 65.6 N m 4041 2942 6983 FLOR -01 - 10000 10000 0 0 - 0 0 0 CEIL -01 - 10000 10000 0.055 28.5 m 2170 7892 10062 wrightsoft Rig ht-Su 'tee Universal 2012 12.0.04 RSU00484 Lom TuckeAVV egand Annex 4- 28- 121Chemistry Research Lab.rup Cat = RTS Building faces: N 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2 /prsn # people Btuh /prsn Btuh/prsn Classrooms 0 292 292 230 190 67160 55480 School lab 0 51 51 315 325 16065 16575 LIGHTS Lamp/blst + fixture W'ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 1.40 0 14000 1.20 1.0 54649 7ato10p Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Schedule ogggg o -E000 -toot Usage Sensible Latent Sens Latent Btuh Btuh 0 1.00 0 0 0 0 1.00 0 1.00 0 1.00 0 1.00 0 1.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION 0 cfm -> x db Temp Diff x Moist. Diff 12.8 x 1.10 -29 x 0.68 Sens Latent 0 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 187329 59572 Envelope 187k 72055 Less extemal cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 wrightsoft Rig ht-Su ite® Universal 2012 12.0.04 RSU00484 Lom Tucker\1Megand Annex 4 -28-12 \Chemistry Research Lab.rup Calc = RTS Building faces: N ti 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6 ) & Drawthru Fan = (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 187329) / ( 1.10 x 20.0 ) = 8517 Actual Cooling Fan .' = 8000 187329 9. VENTILATION OA 3428 cfm —> x db Temp Diff x Moist. Diff 12.8 x 1.10 -29 x 0.68 48254 -12483 10. RETURN AIR PLENUM Lights Total power ( W) 14000 0 Transmission Toad (plenum upper surface) 0 Space Toad credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 180167 59572 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) = ( 70 - 48) = 22 [ Mult = 1.0 ] — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss 15. INFILTRATION Loss 600 cfm x db Temp Diff 3.0 x 1.10 1979 16. SUBTOTAL HEATING LOAD FOR SPACE Envelope Less external heating Less transfer Redistribution 12116 12116 0 0 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0 x Line 16 Loss Less transfer Redistribution 0 0 0 18. VENTILATION OA 3428 cfm x db Temp Diff 3.0 x 1.10 -7163 19. HUMIDIFICATION Inside RH desired • 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes • 1.0 (Max = 52.0 for 2 pane ) 4028 cfm x 1.48 g /100cfm/d = 59.6 gpd Piping rights Right- Suite® Universal 2012 12.0.04 RSU00484 Lom Tucker\wlegand Annex 4-28-12 \Chemistry Research Lab.rup Cale = RTS Building faces: N `°.750ii 0 mNil.ON) m W cti dwooim C u tL ij) O 2012- Ap.�" co �e } 20. RETURN DUCT HEAT LOSS Loss factor x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 45297 Wrig IhtSW Right- Suite4D Universal 2012 12.0.04 RSU00484 Lom Tucker\Wiegand Annex 4- 28- 121Chemistry Research Lab.rup Cain = RTS Building faces: N NOTICE OF COMMENCEMENT A RECORDED COPY MUST BEEP POSTED ON THE JOB SITE AT TIME OF RRST INSPECTION PERMIT NO.✓ 1 `TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement 1. Legal description of property and street/address: 11300 N.E. Second Avenue Miami Shores. Florida 33161 2. Description of improvement Replace existing 20 ton spilt system 3. Owner(s) name and address: Interest in property: Name and address of fee simple titiehofder. 4. Contractor's name, address and phone number Cool Water Air Conditioning Inc. 760 South Shore Drive Miami Beach, Ronda 33141 11111111111111111 111111111111111 1111111111111 CF`H 2 r11174Z 0 7.510 4O2 OR Bk 28093 Ps 23041 (fps) RECORDED 05/01/2012 12:12:06 HARVEY RUVIN, CLERK OF COURT MIAMI—DADE COUNTY? FLORIDA LAST PAGE Space above reserved for use of recording office 5. Surety. (Payment bond required by owner from contractor, if any) Name, address and phone number. Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1Xx)7., Florida Statutes, Name, address and phone number 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number. NI . j S 9. Expiration date of this Notice of Commencement (the expiation date is 1 year from the date of recording unless a dllferent date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE > COMMENCEMENT. • ‘0,.'f Signature(s) of Owners) s)' Authorized Officer/Director/Partner /Manager Prepared By Prepared By Print Name Print Name Title/Office rs41Cscc bion /r Title/Office STATE OF FLORIDA COUNTY OF MIAMI -DADE The foregoing instrument was acknowledged before me this "Of day of �/� G' By r3 °, ❑ Individually, or ❑ as for ❑ Personally known or ❑ produced the following type of identifi Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92.525, FLORIDA STATUTES Under penalties of perjury, 1 declare that I have read the foregoing and that the facts stated in It are true, to the best of my knowledge and belief. Signature(s) of Owner(s) By 123D1 -52 PAGE 3115 s)'s Authorized Officer/Directo _ > ve I REBV 1 1 i t i Is a re copy angina, fiiai , i'.fn= /��r7 dsya� MINE) Ii7 HARVEY F R ►I r'A .