Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-12-511
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 178371 Permit Number: RC -3 -12 -511 Scheduled Inspection Date: September 12, 2012 Inspector: Bruhn, Norman Owner: SANCHEZ, VIVIANE Job Address: 41 NW 109 Street Miami Shores, FL 33168 -4314 Project: <NONE> Contractor: CONTINENTAL BUILDER Permit Type: Residential Construction Inspection Type: Final Building Work Classification: Alteration Phone Number Parcel Number 1121360030290 Phone: (305)797 -4151 Building Department Comments RENOVATION OF MASTER BATH AND RELOCATE LAUNDRY ROOM Passe _7 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 178223. NO ONE HOME AVAILABLE FOR INSPECTIONS JR 9/11/12 ebG September 11, 2012 For Inspections please call: (305)762 -4949 Page 23 of 31 PERMIT# 2c►2.° -n CONTRACTOR: C rl 4 1lam_ (So 1/4L-Dr-2 SUBMITTAL DATE: Yv` C, --t Z, to j -LP (2- ADDRESS: 1-AA " l (D 5'1. NAME: 5.4r's(CA -1 r Z_ RESUBMITAL DATES: PROJECT TYPE: ZONING FIRE STRUCTURAL IMPACT FEES JZ P .A-€./ 2_ HRS /DERM __ ° ,".?°- ELECTRICAL J�l� PLUMBING NOC .1 'cd- ',44/1_,-- MECHANICAL BLDG .i .04* ern- 01701TAMI NOILDINGAUPARTMESIT NOTION OF 00111/tONOIMENT Please file at SINN. Pitr MOUT N'Ulaig: FOLIO NUMBER: State *Markle County of/Maud-Dads The undersigned hereby gives notice that improvements will made to certain real proparbt., swabs accordance with anger 71$.1111, Fled& Statutes, the knowing in presided. in this Notice of Cometencement. Street address 9/00/41 /0 St and Legal de of property 671t6 le 1111111 11111 11111 11111 11111 11111 11111 1111 1111 CFH 2012R03558708 OR Bk 28118 Ps 1023; (1t3g ) RECORDED 05/21/2012 10:00:40 HARVEY ROVIHr CLERK OF COURT _ NIAMI-DADE COUNTY? FLORIDA LAST PAGE Interest in proarty: Name of fee simple titleholder (tether than owner): and address Contractor's marts ,e0ifh 480-/X9/64/ 45 and addreee 23:2 dt" '9 9 Phone number: 304 %, 4'/ $t Amount of Sivety howl: $ : (Payment horst =Muni by owner from contrachan if any) Surety llama and address Pitons make Lenders's name and address Phone numbee Petra= within the Mane &Merida designated by Owner. upon Whian flattens or ether docuruerds MEW be eerctd ee provided by SOCtiOn112.11KIXa).7., Flosida Stables, None and address: endeavors In addition to Wolcott: Owner designator' the framing pareoda) to reesivo a copy oft Lienor'a Notice es gravid' ad in Section inusfiXa Emma pukka% -Nana reoladdress Phone nandisr: ..4. 11 ,, 11,.1,,1“;:" .... telf/i2.41rdor 4/001/garZW c •T1-7751TI cte Ds' Notary Public Print Oath CUM t■ (the expiration date is one a.-diThrent date 'omega/id) 11' _, aricce"),911t i'ligiqiiatAZIanw,i.:Ze....prrf r m,41,7 :*: 1,0A■IISSJON *ES0094$ *47 EXPIRES DecernberiK 2014 (401 398-0163 Floridallotaryeetvickcom hint oymeayanuo...0 6t &4e •ties le Day of /V Res MN , 24102_0_, , ar Ilv426104. ,rxeparedly: Addrese Mit OF R.ORCIA, COtINNCE; MOE 4REBYCSR/IFYfief 1rue copy Otis mitinstaidinthis • "•,- Seat of Op* and aunty Coats .c. TANASHIA ARNOLD 1144 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING EITI MAR 2 0 2092 BY: Permit No. ( 2 S I Master Permit No. Permit Type: BUILDING y/ ROOFING- OWNER: Name (Fee Simple Titleholder): 40;7/Lk 6 is.9-776— Phone #: 395 60,7- o r/ Address: 9� /CfCJ /0f ,p City: //7//,-/n/. &, /225 State: 4,,etl�� Zip: ,3 3/6 C� Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: `// /du /09 66 1- City: Miami Shores Folio/Parcel #: County: Miami Dade Zip: 3f6 Is the Building Historically Designated: Yes Flood Zone: CONTRACTOR: Company Name: Zh%7e/7 P97 4410e45 Phone #: / �� 7 /S1 Address: FZ /711/ 7/-el-c- 2-0V City: 0 //971// State: ,,/ Qualifier Name: R,2 sd4/e% &' — Phone #: ,�7�"9T71s` State Certification or Registration #: e /2 5-6-7 5/1 Certificate of Competency #: Contact Phone#: .3:74-W-?-- V-57" - Email Address: G4r777'7647 rd /f /DPe5 7 ('4y /o y7 DESIGNER: Architect/Engineer: Phone #: o47 Value of Work for this Permit: $ i ®00 )- Square/Linear Footage of Work: Type of Work: °Addition Alteration New ORepair/Replace °Demolition Description of Work. - .��ar�.�� 06' . C _ ,: 2 70,,t7 >4. o o H4 T,' 1347-i-1 ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ ' 0 . t Permit Fee $ CCF $ CO /CC $ deb Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education F Double Fee $ Structural Review $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to att�. ent. for the first n ich s..' 0 4 el Signatures _�_ PPRINNIO The foregoing instrument was ac owledged before me this day of /V , 20 1, by 14�p who is personally known to me oriwho has produced �� ' As identification and who did take an oath. so, a certified copy of the recorded notice of commencement must be posted at the job site (7) days after the building permit is issue In the absence of such posted notice, the ection fee will be charged. NOTARY PUBLIC: Sign: Print: 4 7,477.17,A3 '1 i • r /Li E#di�,V��� • EXPIRES December-06, 2014 My Commission 398 -0153 FbridaNstaryServioe.can Signature Contractor The foregoing instrument was acknowledged before me this day of ka t-1 , 20'Z , by i AID Xi() who is rsona mown to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: APPROVED BY \--/W/7 ?Q��� . Plans Examiner (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Structural Review Sign: Print: My C TINE MA lE MUNOZ olt,PilltreeMMISSION # EE046946. EXPIRES December06, 2014 (407) 398-0153 FloridallotaryService•oom Zoning Clerk IVI iami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT PERMIT #: - 3 -12- -4 3DATE: ` / PJtL /j /� tq() 1\--Lo ❑ kContractor wner ❑ Architect Picked a • - and (other) Address: q( /&U (Q c From the building department on this date in order to have corrections done to plans And /or get County stamps. l understand that the plans need to be brought back to Miami Shores Village Building Depart == t to continue permitting process. l /�f /� IO l 1 Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: PERMIT CLERK INITIAL: Pe mit o: 12-51 Job Name: April 10, 2012 Miami Shores Viiiage Building Department Building Critique Sheet 1) Provide all permit applications prior to any further review. 2) Provide corrections for Electric. 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 762 -4859 (1/412 ria-C-64 M lami Shores Village Building Department Permit No: 12- I-71 Job Name: f®. -pC' 4-' Date: ��' 9)-x, ELECTRIC Critique Sheet 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Ze «),S Xi, rn /4/24_ 7-0 i3vc4,ate-P4 , 3 )3.41,iL,lz. tPar .�2- ',' 4 eI e if/SSA /(fr .,'�'G -J L t ' si 14 yp airt- iLe ice — 3' ,r qf' L � ' IhP Z Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Review Complete by: Michael A. Devaney SR. Chief Electrical Inspector FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: INTERIOR REMODELATION. Street 41 NW 109 STREET t City, State, Zip: MIAMI SHORES , FL , Owner. Design Location: FL, Miami rc� ; Iddr Name: MERLO AND ASSOCIATES t'° rm Office: Perm Number fiction: I° fi :7 L-0;11 v` 6 2C:2Juris 1. New construction or existing Existing 2. Single family or multiple family Single 3. Number of units, if multiple family 1 4. Number of Bedrooms 4 5. Is this a worst case? No 6. Conditioned floor area (ft2) 1979 7. Windows(322.3 sqft.) Description a. U- Factor. Sgl, U =0.60 SHGC: SHGC =0.40 b. U- Factor. N/A SHGC: c. U- Factor. N/A SHGC:, d. U- Factor WA SHGC: e. U- Factor. N/A SHGC: 8. Floor Types (1979.0 sqft.) Insulation, a. Crawlspace R =19.0 b. N/A R= c. WA R= (Projecte - family Area 322.25 ft2 ft2.,, r :, E + , ,Aria . ° 979.00 1979.00:' ft2 ft2 9. Wall Types (2104.5 sqft.) Insulation Area a. Concrete Block - Int Instil, Exterior R=4.1 2104.50 ft2 b. N/A R= ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types (1979.0 sgft) Insulation Area a. Under Attic (Vented) R =30.0 1979.00 ft2 b. WA R= ft2 c. N/A R= ft2 11. Ducts a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 395.8 ft2 12. Cooling systems a. Central Unit Cap: 56.5 kBtu/hr fi; ° SEER: 15 13. Heating systems / a. Electric Heat Pump Cap: 56.5 kBtu/hr HSPF: 7.7 of water systems a. Electric Cap: 40 gallons EF: 0.92 r / b. Conservation features None 15. Credits Pstat Glass/FloorArea: 0.163 Total As -Built Modified Loads: 58.86 PASS Total Baseline Loads: 71.67 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. °� PREPARED BY ` �e `� Review of the plans and OE 8 7 ' specifications covered by this �• °v f® * t3,t, calculation indicates compliance,," with the Florida Energy Code. �+ �rard °�� Before construction is completed DATE* 13 1-2- this building will be inspected for c . compliance with Section 553.908 'H Florida Statutes. 0 I hereby certify that this building, as designed, is in compliance the Florida Energy Cod OWNER/AGENT• 1- 1 eC1.0 BUILDING OFFICIAL* DATE: 1, DATE 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 PROJECT Title: INTERIOR REMODELATION Bedrooms: 4 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 1979 Lot # Owner. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: MERLO AND ASSOCIATES Rotate Angle: 0 Street: 41 NW 109 STREET Permit Office: Cross Ventilation: County: DADE Jurisdiction: Whole House Fan: City, State, Zip: MIAMI SHORES , Family Type: Single - family FL , New/Existing: Existing (Projected) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL_MIAMI_INTL AP 1 51 90 75 70 149.5 56 Low FLOORS V# Floor Type Exposed Perimeter Wall Ins. R -Value Area Floor Joist R -Value Tile Wood Carpet 1 Crawlspace 245 ft 0 1979 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar Deck V # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 2086 ft2 0 ft2 Medium 0.96 Yes 0 18.4 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1979 ft2 Y N CEILING V # Ceiling Type R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 1979 ft2 0.11 Wood WALLS Cavity SR -Value thing Framing Solar / hea V # Omt Adjacent To Wall Type R -Value Area Fraction Absor. 1 N Exterior Concrete Block - Int Insul 4.099999 471 ft2 0 0.75 2 S Exterior Concrete Block - Int Insul 4.099999 471 ft2 0 0.75 3 E Exterior Concrete Block - Int Insul 4.099999 581.25 ft2 0 0.75 4 W Exterior Concrete Block - Int Insul 4.099999 581.25 ft2 0 0.75 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 2 of 5 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DOORS V# Omt Door Type Storms U -Value Area 1 S Wood None 0.460000 20.5 ft2 WINDOWS Orientation shown is the entered, asBuiit orientation. V # Omt Frame Panes NFRC U- Factor SHGC Storms Overhang Area Depth Separation Int Shade Screening 1 N Metal Single (Clear) 2 N Metal Single (Clear) 3 N Metal Single (Clear) 4 S Metal Single (Clear) 5 S Metal Single (Clear) 6 S Metal Single (Clear) 7 E Metal Single (Clear) 8 E Metal Single (Clear) 9 E Metal Single (Clear) 10 W Metal Single (Clear) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 0.6 0.4 N 9 ft2 2 ft 0 in 1 ft 0 in HERS 2006 3 ft2 2 ft 0 in 1 ft 0 in HERS 2006 52.00000 2 ft 0 in 1 ft 0 in HERS 2006 20 ft2 2 ft 0 in 1 ft 0 in HERS 2006 30.83333 2 ft 0 in 1 ft 0 in HERS 2006 34.66666 2 ft 0 in 1 ft 0 in HERS 2006 78.58333 2 ft 0 in 1 ft 0 in HERS 2006 52.00000 2 ft 0 in 1 ft 0 in HERS 2006 20.5 ft2 2 ft 0 in 1 ft 0 in HERS 2006 21.66666 2 ft 0 in 1 ft 0 in HERS 2006 None None None None None None None None None None INFILTRATION & VENTING V Method SLA CFM 50 ACH 50 ELA EqLA - Forced Ventilation - Run Time Supply CFM Exhaust CFM Fraction Fan Watts Default 0.00036 1869 6.30 102.6 192.9 0 cfm 0 cfm 0 0 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 15 56.5 kBtu/hr 1695 cfm 0.75 sys#1 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 7.7 56.5 kBtu/hr sys#1 HOT WATER SYSTEM # System Type EF Cap Use . SetPnt Conservation 1 Electric 0.92 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DUCTS - Supply — — Retum — Air Percent V # Location R -Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 395.8 ft Attic 98.95 ft Default Leakage Interior (Default) (Default) % TEMPERATURES Programable Thermostat: Venting LX Jan Venting [[�X]] Jan Y x Feb Feb 7C Mar [[�Xl] Mar Cei ing Fans: May Apr [X May LxJ Jun X] Jul L�J Aug X] Sep X Oct X] Nov [X] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEN) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5 1 FORM 1100A -08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 41 NW 109 STREET MIAMI SHORES, FL, PERMIT #: INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors NI 106.AB.1.1 Maximum: .3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. ✓ Exterior & Adjacent Walls NI 106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors NI 106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. / y Ceilings NI 106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. / 1/ Recessed Lighting Fixtures NI106.AB.12 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. 1/ Multi-story Houses NI 106.AB.1.2 Air barrier on perimeter of floor cavity between floors. I/ Additional Infiltration reqts NI 106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters NI112.AB.3 Comply with efficiency requirements in Table NI112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. Swimming Pools & Spas NI 112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads NI 112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems NI 110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section NI 110.AB. Ducts in unconditioned attics: R -6 min. insulation. HVAC Controls NI 107.AB.2 Separate readily accessible manual or automatic thermostat for each system. 1/ Insulation NI104.AB.1 N1102.B.1.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. I/ 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 5 of 5 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Project Title: INTERIOR REMODELATION Building Type: User 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 Reference City: Miami, FL (Defaults) Winter Temperature Difference: 20.0 F (MJ8 99 %) Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 1 2 3 4 5 6 7 8 9 10 1, NFRC 0.40 Metal 0.60 N 9.0 12.0 1, NFRC 0.40 Metal 0.60 N 3.0 12.0 1, NFRC 0.40 Metal 0.60 N 52.0 12.0 1, NFRC 0.40 Metal 0.60 S 20.0 12.0 1, NFRC 0.40 Metal 0.60 S 30.8 12.0 1, NFRC 0.40 Metal 0.60 S 34.7 12.0 1, NFRC 0.40 Metal 0.60 E 78.6 12.0 1, NFRC 0.40 Metal 0.60 E 52.0 12.0 1, NFRC 0.40 Metal 0.60 E 20.5 12.0 1, NFRC 0.40 Metal 0.60 W 21.7 12.0 Window Total 322.3(sqft) 108 Btuh 36 Btuh 624 Btuh 240 Btuh 370 Btuh 416 Btuh 943 Btuh 624 Btuh 246 Btuh 260 Btuh 3867 Btuh Walls 1 2 3 4 Type Omt. Ueff. R -Value Area X HTM= (Cav /Sh) Conc BIk,Hollow - Ext (0.149) 4.1/0.0 407 2.98 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 365 2.98 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 430 2.98 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 560 2.98 Wall Total 1762(sqft) Load 1215 Btuh 1089 Btuh 1284 Btuh 1670 Btuh 5258 Btuh Doors 1 Type Storm Ueff. Area X HTM= Wood - Exterior, n (0.460) 21 9.2 Door Total 21(sqft) Load 189 Btuh 189Btuh Ceilings 1 Type /Color /Surface Ueff. R -Value Area X HTM= Vented Attic/UShing (0.032) 30.0/0.0 1979 0.6 Ceiling Total 1979(sqft) Load 1261 Btuh 1261 Btuh Floors 1 Type Ueff. R -Value Size X HTM= Stem /Crawlsp(Carpet)(v) (0.049) 19.0/0.0 1979.0 sqft 0.8 Floor Total 1979 sqft Load 1523 Btuh 1523 Btuh Zone Envelope Subtotal: 12097 Btuh Infiltration Type ACH Zone Volume Wall Ratio CFM= Natural 0.50 15832 1.00 148.4 3265 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0 -Attic) (DLM of 0.399) 6132 Btuh Zone #1 Sensible Zone Subtotal 21494 Btuh EnergyGauge® / USRFZB v2.8 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: INTERIOR REMODELATION Building Type: User 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 ftfliOLE HOUS Ti ALS Totals for Heating Subtotal Sensible Heat Loss Ventilation Sensible Heat Loss Total Heat Loss 21494 Btuh 0 Btuh 21494 Btuh 1. Electric Heat Pump 56500 Btuh Key: Window types - NFRC (Requires U- Factor and Shading coefficient(SHGC) of glass as numerical values) or - Glass as 'Clear' or Tint' (Uses U -Factor and SHGC defaults) U - (Window U- Factor) HTM - (ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge® / USRFZB v2.8 Page 2 41 NW 109 STREET MIAMI SHORES, FL Reference City: Miami, FL Project Title: INTERIOR REMODELATION 3/4/2012 Temperature Difference: 15.0F(MJ8 99 %) Humidity difference: 58gr. Component Loads for Room/Zone #1: Main Window Type* Panes SHGC U InSh IS Ornt Overhang Len Hgt Window Area(sgft) Gross Shaded Unshaded HTM Shaded Unshaded Load 1 1 NFRC 0.40, 0.60 No No N 2.0ft. 1.0ft. 9.0 0.0 9.0 18 18 159 Btuh 2 1 NFRC 0.40, 0.60 No No N 2.0ft. 1.0ft. 3.0 0.0 3.0 18 18 53 Btuh 3 1 NFRC 0.40, 0.60 No No N 2.0ft. 1.0ft. 52.0 0.0 52.0 18 18 919 Btuh 4 1 NFRC 0.40, 0.60 No No S 2.0ft. 1.0ft. 20.0 20.0 0.0 18 19 353 Btuh 5 1 NFRC 0.40, 0.60 No No S 2.0ft. 1.0ft. 30.8 30.8 0.0 18 19 545 Btuh 6 1 NFRC 0.40, 0.60 No No S 2.0ft. 1.0ft. 34.7 34.7 0.0 18 19 613 Btuh 7 1 NFRC 0.40, 0.60 No No E 2.0ft. 1.0ft. 78.6 7.6 71.0 18 48 3542 Btuh 8 1 NFRC 0.40, 0.60 No No E 2.0ft. 1.0ft. 52.0 8.6 43.4 18 48 2236 Btuh 9 1 NFRC 0.40, 0.60 No No E 2.0ft. 1.0ft. 20.5 2.0 18.5 18 48 924 Btuh 10 1 NFRC 0.40, 0.60 No No W 2.0ft. 1.0ft. 21.7 5.7 15.9 18 48 867 Btuh Window Total 322 (sqft) 10211 Btuh Walls Type U -Value R -Value Area(sqft) HTM Load Cav /Sheath 1 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 407.0 2.2 911 Btuh 2 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 365.0 2.2 817 Btuh 3 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 430.2 2.2 963 Btuh 4 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 559.6 2.2 1253 Btuh Wall Total 1762 (sqft) 3944 Btuh Doors Type Area (sqft) HTM Load 1 Wood - Exterior 20.5 13.8 283 Btuh Door Total 21 (sqft) 283 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle /RB 0.032 30.0/0.0 1979.0 1.08 2143 Btuh Ceiling Total 1979 (sqft) 2143 Btuh Floors Type R -Value Size HTM Load 1 Stem /Crawlsp(Carpet)(v) 19.0 1979 (sqft) 0.6 1149 Btuh Floor Total 1979.0 (sqft) 1149 Btuh Zone Envelope Subtotal: 17729 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio CFM= Load SensibleNatural 0.40 15832 1.00 118.7 1959 Btuh Internal Occupants Btuh /occupant Appliance Load gain 10 X 230 + 3500 5800 Btuh Sensible Envelope Load: 25488 Btuh Duct load Average sealed, Supply(R6.0- Attic), Return(R6.0 -Attic) (DGM of 0.294) 7505 Btuh Sensible Zone Load 32994 Btuh EnergyGauge® / USRFZB v2.8 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL_AP INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 The following window Excursion will be assigned to the system loads. Windows Duct load July excursion for System 1 Excursion Subtotal: 632 Btuh 632 Btuh 186 Btuh Sensible Excursion Load 818 Btuh EnergyGauge® / USRFZB v2.8 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL_AP INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 WHOLE HOUSE TOTALS Whole House Totals for Cooling Sensible Envelope Load All Zones Sensible Duct Load Total Sensible Zone Loads Sensible ventilation Blower Total sensible gain Latent infiltration gain (for 58 gr. humidity difference) Latent ventilation gain Latent duct gain Latent occupant gain (10 people @ 200 Btuh per person) Latent other gain Latent total gain TOTAL GAIN 26120 Btuh 7691 Btuh 33811 Btuh 0 Btuh 0 Btuh 33811 Btuh 4682 Btuh 0 Btuh 2562 Btuh 2000 Btuh 2800 Btuh 12044 Btuh 45855 Btuh EQUIPMENT 1. Central Unit 56500 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U- Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) EnergyGauge® / USRFZB v2.8 Version 8 Page 3 Residential System Sizing Calculation Summary Project Title: INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(7 ft.) Temp Range(L) Humidity data: Interior RH (50 %) Outdoor wet bulb (77F) Humidity difference(58gr.) Winter design temperature(MJ8 99 Winter setpoint Winter temperature difference %) 50 70 20 F F F Summer design temperature(MJ8 99 %) 90 Summer setpoint 75 Summer temperature difference 15 F F F Total heating load calculation 21494 Btuh Total cooling load calculation 45855 Btuh Submitted heating capacity Total (Electric Heat Pump) Heat Pump + Au iliary(0.OkW) % of calc 262.9 262.9 Btuh 56500 56500 Submitted cooling capacity % of calc Sensible (SHR = 0.75) 125.3 Latent 117.3 Total (Electric Heat Pump) 123.2 Btuh 42375 14125 56500 WINTER CALCULATIONS Winter Heating Load for 1979 soft Load component Load Load Window total 322 Window total 322 sqft 3867 Btuh Wall total 1762 sqft 5258 Btuh Door total 21 sqft 189 Btuh Ceiling total 1979 sqft 1261 Btuh Floor total 1979 sqft 1523 Btuh Infiltration 148 cfm 3265 Btuh Duct loss Sens. Ventilation 0 cfm 6132 Btuh Subtotal 0 21494 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS Btuh Latent gain(infiltration) 21494 Btuh Summer Cooling Load for 1979 sgft SUMMER CALCULATIONS Load component Load Window total 322 sqft 10842 Btuh Wall total 1762 sqft 3944 Btuh Door total 21 sqft 283 Btuh Ceiling total 1979 sqft 2143 Btuh Floor total 1149 Btuh Infiltration 119 cfm 1959 Btuh Internal gain 5800 Btuh Duct gain 7691 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 33811 Btuh Latent gain(ducts) 2562 Btuh Latent gain(infiltration) 4682 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internal /occupants /other) 4800 Btuh Total latent gain 12044 Btuh TOTAL HEAT GAIN 45855 Btuh 8th Edition Infil.(14 ) EnergyGauge® System Sizing PREPARED BY: DATE: EnergyGauge® / USRFZB v2.8 FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Street; City, State, Zip: Owner. Design Location: INTERIOR REMODELATION2 41 NW 109 STREET MIAMI SHORES , FL , FL, Miami 1. New construction or existing 2. Single family or mulibb family 3. Ntrnber of untis, If multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Cordffioned floor area (112) 7. Wtndows(132.8 sett.) a. U- Facto: SHGC: b. U- Factor: SHGC: c. U- Factor. SHGC: d. U -Faces: SHGC: e. U- Factor. SHGC: Description Area Sgi, U411.60 132.75 ft2 SHGC7.40 WA fee Bidder Name: MERLO AND ASSOCIATES Pen it Office: Permit Number: Jurlsdldion: 9. Wail Types (1233.0 soft.) a. Concrete Mock - Int bad, Exterbr b. N/A c. N/A d. NIA 10. Ceiling Types (777.0 sett.) a. Under Attic (Vented) b. WA c. NIA 8. Floor Types (777.0 sgfL) a. CrawLspace b. N/A c. N/A Insulation Area R=19.0 777.00 ft2 R= 112 R= lie Insulation Area R=4.1 1233.00 ft2 R= 102 R= 112 R= 112 Insulation Area R=30.0 777.00 ft2 R= 1!2 R= 12 11. Duds a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 250112 12. Cooing systems a. Cenbal Unit 13. Heating systems a. Electric Heat Pump 14. Hot watersystems a. Electric Cap: 24.2 kBtulhr SEER: 15 Cap: 22.8 kBtuthr HSPF: 7.7 Cap: 40 gallons EF: 0.92 Glass/Floor Area: 0.171 b. Cordon features None 15. Credits Total As -Built Modified Loads: 29.39 Total Baseline Loads: 34.94 I hereby certify that the plans and spectficalions covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: 12. 1 hereby certify that this buiiling, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: fir% DATE: Review of the plans and specifications covered by this calculation indIcates compliance e with the Florida Energy Code. Before construction is completed this b ikfing will be inspected for c ompflance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: - Compliance requires a roof absorptance test in accordance with N1104.A.4. 3/4/2012 5:36 PM EnergyGattgedb USA - FlaRes2008 5 e PROJECT Tide: INTERIOR REMODELATION Bedrooms: 1 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 777 Lot* Owner. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: MERLO AND ASSOCIATES Rotate Angle: 0 Street 41 NW 109 STREET Permit Office: Cross Ventilation: County: DADE Jurisdiction: Whole House Fan: City, State, Zip: MIAMI SHORES , Family Type: Single- family FL , New/Existing: Existing (Projected) Comment CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTL AP 1 51 90 75 70 149.5 56 Low FLOORS V # Floor Type Exposed Perimeter Wall Ins. R-Value Area Floor Joist R -Value Tile Wood Carpet 1 Crawlspace 137 ft 0 .777 ft2 19 0 0 1 ROOF J Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 819 62 0 ft2 Medium 0.96 Yes 0 18.4 deg ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 777 ft2 Y N CEILING V # Ceiling Type R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 777 Its 0.11 Wood WALLS Cavity Area Sheathing e Framing Abssor. # Omt Adjacent To Wall Type 1 N Exterior Concrete Blocc - Int Insul 4.099999 162.75 ft2 0 0.75 2 S Exterior Concrete Block - Int Insul 4.099999 162.75 ft2 0 0.75 3 E Exterior Concrete Blocs - Int Insul 4.099999 453.75 ft' 0 0.75 4 N Exterior Concrete Block - Int Insul 4.099999 453.75 ft' 0 0.75 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 2 of 5 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 3 of 6 DOORS V# Omt Door Type Storms U -Value Area 1 S Wood None 0.460000 20.5 ft2 WINDOWS Orientation shown is the entered, asBuilt orientation. # Omt Frame Panes Overhang NFRC U -Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N Metal Single (Clear) 2 N Metal Single (Clear) 3 E Metal Single (Clear) 4 E Metal Single (Clear) 5 N Metal Single (Clear) Yes 0.6 0.4 N 9 ft2 2 ft 0 in 1 ft 0 in Yes 0.6 0.4 N 3 (t' 2 if 0 in 1 ft 0 in Yes 0.6 0.4 N 78.58333 2 ft 0 in 1 ft 0 in Yes 0.6 0.4 N 20.5 ft2 2 ft 0 In 1 ft 0 In Yes 0.6 0.4 N 21.66666 2 ft 0 In 1 It 0 in HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 None None None None None INFILTRATION & VENTING Method SLA -- Forced Ventilation --- CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Run Time Fraction Fan Watts Default 0.00036 734 6.30 40.3 75.8 0 cfm 0 cfrn 0 0 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 15 242 kBtu/hr 726 dm 0.75 sys#1 HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 7.7 22.8 kBtu/hr sys#1 HOT WATER SYSTEM V # System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS V — Supply — # Location R -Value Area — Retum — Air Percent Location Area Leakage Type Handler CFM 25 Leakage GIN RLF 1 Attic 6 250 ft' Attic 100 ft' Default Leakage Interior (Default) (Default) % 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 3 of 6 3/4/2012 5:36 PM EnergyGaugee USA - FlaRes2008 Page 4 of 5 TEMPERATURES Programable Thermostat Y Ceiling Fans: Venting RI Jan Venting [x] Jan 7( Feb R] Feb X Mar [xl Mar [X� tttnnnlll Apr Jun Jul Aug X Sep Oct 111 Nov C [Xj Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 68 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/4/2012 5:36 PM EnergyGaugee USA - FlaRes2008 Page 4 of 5 FORM 1100A -08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 41 NW 109 STREET MIAMI SHORES, FL, PERMIT #: INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHE9K �/ Exterior Windows & Doors N 1106.AB.1.1 Maximum: .3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls NI 106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Floors NI 106AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Ceilings NI 106AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. / y/ Recessed Lighting Fixtures N 1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. / I/ Multi-story Houses NI 106AB.1.2 Air barrier on perimeter of floor cavity between floors. / t� Additional Infiltration reqts NI106.A8.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters NI112.AB.3 Comply with efficiency requirements in Table NI112.ABC.3 Switch or dearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. / y Swimming Pools & Spas N 1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads NI 112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems NI 110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section NI 110.AB. Ducts in unconditioned attics: R-6 min. insulation. ✓ HVAC Controls NI 107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation NI 104AB.1 NI102.B.1.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. 3/4/2012 5:36 PM EnergyGaugera USA - FlaRes2008 Page 5 of 5 0511712012 15:13 3057400518 1 2 �,• St ( ACCEPTANCE INSURANCE CERTIFICATE OF LIABILITY INSURANCE PAGE 01101 RATE (MMIDUIYYYY) 05/17/12 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED EY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terns and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In Ileu of such endorsement(s). PRODUCER Acceptance Insurance Services 8887 S.W. 40th St. Miami, FL 33155 Phone (305740 -0515 INSURED Continental Builders, Inc 7230 NW 174 Street # 204 Miami, FL 33015- ax (305)740 -0518 CONTACT NAME: Rene E. Semayoa PHONE (305)740-0515 9. sDDREj - renell aaceptenceinsseMces.ccm FAX Noll (305)740 -0518. INSURER(SI AFFORDING COVERAGE NAIC n INSURERA: Republic Vanguard Insurance Co. 40479 (305) 7974151 INSURER s : INSURER C INSURER D INSURER E INsuRER F COVERAGES CERTIFICATE NUMBER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OP INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR A TYPE OF INSURANCE I ADDLsuBR FWD POLICY NUMBER {M�MIDUQJYYI Yp 03/07/2012 /1f WY) 03/07/2013 LIMITS $ 1,000,000 -00 $ 100,000.00 t;ENERAI. LIABILITY [A COMMERCIAI. GENERAL LIABILr1Y ❑ 0 CLAIMS -MADE �J OCCUR ❑ N N PGL- 000883 -12 E$ O ,ce) I DEXP(Anyarrecson) $ 5,000.00 PERSONAL &Am INJURY $ 1,010,000.00 • GENERAL AGGREGATE $ 2.000,000.00 GEN'L AGGREGATE LIMIT APPueS PER: POI ICY ❑ LOC PRODUCTS • COMPJOP AGG $ 1,000,000.00 $ AuTOMOSILE LIABILITY El ANY AUTO ii OWNED • AUTOS ❑ HIRED AUTOS AA NON-OWNED E o C9MSINdDSINGLE UNIT BBODILY $ INJURY (Per person) $ BODILY INJURY (Per accident) $ p pA _E $ S ii UMSRELLALIAB ❑OCCUR • Excess LLAB R CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ • mu ❑ RErENTIONt $ WORMERS COMPENSATION AND EMPLOYERS' LtASILITY Y/ N ANY PROPRIETORIL'ARTNERJEXECIME ❑ T RXT TU- ❑ FR E.L. EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? { �N/A (mandatory In NM) L.-.-I EL DISEASE • EA EMPLOYEE $ Eyes, describe under DESCRIPTION OF OPERATIONS below El. DISEASE- PquCY LIMIT S DESCRIPTION OF OPERATIONS 1 LOCATIONS 1 VEHICLES (Attach ACORD 101, Addltlonal Remarks SGHedule, It morn swims Is required) GENERAL CONTRACTOR Request policy for complete details on endorsements and exclusions. CANCELLATION MIAMI SHORES BUILDING DEPARTMENT 10050 NE 2nd Ave MIAMI SHORES, FL, 33138 FAX 305.756 -8972 ACORD 25 (2010/05) QF SHOULD ANY QF TH e. ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. • AUTHORIZED REPRESENTATIVE O 1988 -2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: INTERIOR REMODELATION fi Street City, State, Zip: Owner. Design Location: FL, Miami 41 NW 109 STREET , MIAMI SHORES , FL . 1. New construction or existing 2. Single family or mu tiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (1t2) 7. Wrnctows(322.3 soft.) a. U- Facto: SHGC: b. U -Factor SHGC: c. U- Factor: SHGC: d. U- Factor. SHGC: e. U- Factor. SHGC: 8. Floor Types (1979.0 soft.) a. Crawlspace b. N/A c. NIA Name: MERLO AND ASSOCIATES rmit Office: Number: e. , Description Sgt, U1.60 SHGC =.40 WA Exist (Projecte Single-family 1 4 No 1979 Area 32225 ft2 9. Wag Types (2104.5 sqft.) a. Concrete Blodc - Int fowl, Exterior b. N/A c. NIA d. NSA 10. Cei9ng Types (1979.0 shift.) a. Under Attic (Verted) b. NIA c. NIA e 11. Ducts a Sup: tic RE", Alt Irnt Insulation Area R=4.1 2104.50 iP R= ft2 R= tta R= ft2 Iron Area Itt=30 9 1979.00 tt2 ft re R= Insulation Area R =19.0 1979.00 ft2 R= ft2 12. Cooling;sysb3nrs - t, a Central Unit 13. Heating systems a. Ferric Heat Pump 14. Hot water systems a. Epic 7P ' b. Conservatlon feature 395.8 ft2 Cap: 56.5 kBtu/hr SEER: 15 Cap: 56.5 kBtu!tw HSPF: 7.7 Gap: 40 gailoas EF: 0.92 15. Credits , Pstat Glass/Floor Area 0.163 Total As -Built Modified Loads: 58. Total Baseline Loads: 71.1 I hereby certify that the plans and spec iflcations covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: e i�� c-1.0 I hereby certify that this building, as designed, is in compliance with the Florida Energy Cod OWNER/AGENT: ` ' 1 Pi` 0 DATE: SS Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building wilt be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 314/2012 5 :19 PM Ear USA - FlaRes2008 of 5 PROJECT Title: INTERIOR REMODELATION Bedrooms: 4 Adress Type: Street Address Building Type: FLAsBuiit Conditioned Area: 1979 Lot # Owner. Total Stones: 1 Bloc k/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: MERLO AND ASSOCIATES Rotate Angle: 0 Street 41 NW 109 STREET Permit Office: Cross Ventilation: County: DADE Jurisdiction: Whole House Fan: City, State, Zip: MIAMI SHORES , Family Type: Single - family FL , New/Existing: Existing (Projected) Comment CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTLAP 1 51 90 76 70 149.5 56 Low FLOORS V # Floor Type Exposed Perimeter Wall Ins. R -Value Area Floor Joist R -Value Tile Wood Carpet 1 Crawlspace 245 ft 0 1979 ft2 19 0 0 1 ROOF Roof Gable Roof Solar Deck V # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 2086 ft2 0 ft2 Medium 0.96 Yes 0 18.4 deg ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1979 ft2 Y N CEILING V # Ceiling Type R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 1979 ft2 0.11 Wood WALLS V # Omt Adjacent To Wail Type R Valtue Area R-- -VVallue Frame Absor. 1 N Exterior Concrete Block - Int Insul 4.099999 471 ft2 0 0.75 2 S Exterior Concrete Blocc - Int Insul 4.099999 471 ft2 0 0.75 3 E Exterior Concrete Block - Int Insul 4.099999 58125 ft' 0 0.75 4 W Exterior Concrete Block - Int Insul 4.099999 581.25 ft2 0 0.76 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 2 of 5 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DOORS V # Omt Door Type Storms U -Value Area 1 S Wood None 0.460000 20.5 ft' WINDOWS Orientation shown is the entered, asBuilt orientation. V # Omt Frame Panes Overhang NFRC U -Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N Metal Single (Clear) 2 N Metal Single (Clear) 3 N Metal Single (Clear) 4 S Metal Single (Clear) 5 S Metal Single (Clear) 6 S Metal Single (Clear) 7 E Metal Single (Clear) 8 E Metal Single (Clear) 9 E Metal Single (Clear) 10 W Metal Single (Clear) Yes 0.6 0.4 N 91t$ 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 3 ft2 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 52.00000 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 20 ft' 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 30.83333 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 34.66666 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 78.58333 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 52.00000 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 20.5 ft2 2 ft 0 In 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 21.66666 2 ft 0 in 1 ft 0 in HERS 2006 None None None None None None None None None None INFILTRATION & VENTING Method SLA - Forced Ventilation - Run Time CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Fan Watts Default 0.00036 1869 6.30 102.6 192.9 0 cfm 0 dm 0 0 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 15 56.5 kBtulhr 1695 cfm 0.75 sys#1 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 7.7 58.5 kBtu/hr sys#1 HOT WATER SYSTEM V # System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DUCTS — Supply — — Return -- Air Percent V # Location R -Value Area Locaton Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 395.8 it Attic 98.95 ft Default Leakage Interior (Default) (Default) % TEMPERATURES Programable Venting Venting Thermostat Y [[�Xj [[X�jj CeeXlll]ing (X) Jan pC1 Feb [X) MMar LxJ Apr [IXXjI Jan [[XX]] Feb [[�X]) Mar t[�Xl] Fans: riig txl May t ^i EXl Jun Jul 1X Aug Sep PC] Oct lCJ Nov [X] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Goofing (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 7788 Heating ) PM 66 66 66 66 66 68 68 66 Heating (WEH) AM 68 66 66 66 68 68 68 68 68 68 68 66 3/412012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5 1 FORM 1100A -08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 41 NW 109 STREET MIAMI SHORES, FL, PERMIT #: INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm/sq.ft. window area; .5 cfm /sq.ft. door area. ✓ Exterior & Adjacent Walls NI 106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors NI 106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. / Ceilings NI 106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. / �/ Recessed Lighting Fixtures NI106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. / J✓ Multi-story Houses NI 106AB.1.2 Air barrier on perimeter of floor cavity between floors. / Additional Infiltration reqts NI 106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHEC Water Heaters NI112.AB.3 Comply with efficiency requirements in Table NI112.ABC.3 Switch or dearly marked circuit breaker (electric) or cutoff (gas) must be provided. Extemal or built-in heat trap required. YYYY Swimming Pools & Spas NI 112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads NI112AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. f/ Air Distribution Systems N 1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section NI 110.AB. Ducts in unconditioned attics: R-6 min. insulation. / �/ HVAC Controls NI 107.AB.2 Separate readily accessible manual or automatic thermostat for each system. / Insulation NI 104.AB.1 N1102.B.1.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. / 3/4/2012 5:19 PM EnergyGauge® USA - FlaRes2008 Page 5 of 5 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Project Title: INTERIOR REMODELATIDN Building Type: User 41 NW 109 STREET MIAMI SHORES, FL Reference City: Miami, FL (Defaults) Winter Temperature Difference: 20.0 F (MJ8 99 %) Component Loads for RoomlZone' 3/4/2012 Window Panes/ Type Frame U Orientation Area(sgft) X HTM= Load 1 2 3 4 5 6 7 8 9 10 1, NFRC 0.40 Metal 0.60 N 9.0 12.0 1, NFRC 0.40 Metal 0.60 N 3.0 12.0 1, NFRC 0.40 Metal 0.60 N 52.0 12.0 1, NFRC 0.40 Metal 0.60 S 20.0 12.0 1, NFRC 0.40 Metal 0.60 S 30.8 12.0 1, NFRC 0.40 Metal 0.60 S 34.7 12.0 1, NFRC 0.40 Metal 0.60 E 78.6 12.0 1, NFRC 0.40 Metal 0.60 E 52.0 12.0 1, NFRC 0.40 Metal 0.60 E 20.5 12.0 1, NFRC 0.40 Metal 0.60 W 21.7 12.0 IMndow Total 322.3(sgft) 108 Btuh 36 Btuh 624 Btuh 240 Btuh 370 Btuh 416 Btuh 943 Btuh 624 Btuh 246 Btuh 260 Btuh 3867 Btuh Walls 1 2 3 4 Type Omt. Ueff. R -Value Area X HTM= (Cav/Sh) Conc BIk,Hollow - Ext (0.149) 4.1/0.0 407 2.98 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 365 2.98 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 430 2.98 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 560 2.98 Wall Total 1762(sgft) Load 1215 Btuh 1089 Btuh 1284 Btuh 1670 Btuh 5258 Btuh Doors 1 Type Storm Ueff. Area X HTM= Wood - Exterior, n (0.460) 21 9.2 Door Total 21(sgft) Load 189 Btuh 189Btuh Ceilings 1 Type /Color /Surface Ueff. R -Value Area X HTM= Vented Attic/UShing (0.032) 30.0/0.0 1979 0.6 Ceiling Total 1979(sgft) Load 1261 Btuh 1261 Btuh Floors 1 Type Ueff. R -Value Size X HTM= Stem/Crawlsp(Carpet)(v) (0.049) 19.0/0.0 1979.0 sgft 0.8 Floor Total 1979 sgft Load 1523 Btuh 1523 Btuh Zone Envelope Subtotal: 12097 Btuh Infiltration Type ACH Zone Volume Wall Ratio CFM= Natural 0.50 15832 1.00 148.4 3265 Btuh Duct Toad Average sealed, Supply(R6.0- Attic), Retum(R6.0 -Attic) (DLM of 0.399) 6132 Btuh Zone #1 Sensible Zone Subtotal 21494 Btuh EnergyGauge® / USRFZB v2.8 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: INTERIOR REMODELATION Building Type: User 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 SE TOT Totals for Heating Subtotal Sensible Heat Loss Ventilation Sensible Heat Loss Total Heat Loss 21494 Btuh 0 Btuh 21494 Btuh 1. Electric Heat Pump 56500 Btuh Key. Window types - NFRC (Requires U- Factor and Shading coefficient(SHGC) of glass as numerical values) or - Glass as 'Gear' or 'Tint' (Uses U -Factor and SHGC defaults) U - (Window U- Factor) HTM - (Manual] Heat Transfer Multiplier) Version 8 EnergyGauge® / USRFZB v2.8 Page 2 Residential Load m Room by Room Component Details Project Title: INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL Reference City: Miami, FL 3/4/2012 Temperature Difference: 15.OF(MJ8 99 %) Humidity difference: 58gr. Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 1 1 NFRC 0.40, 0.60 No No N 2.0ft. 1.0ft. 9.0 0.0 9.0 18 18 159 Btuh 2 1 NFRC 0.40, 0.60 No No N 2.0ft. 1.0ft. 3.0 0.0 3.0 18 18 53 Btuh 3 1 NFRC 0.40, 0.60 No No N 2.0ft. 1.01t. 52.0 0.0 52.0 18 18 919 Btuh 4 1 NFRC 0.40, 0.60 No No S 2.Oft. 1.0ft. 20.0 20.0 0.0 18 19 353 Btuh 5 1 NFRC 0.40, 0.60 No No S 2.0ft. 1.0ft. 30.8 30.8 0.0 18 19 545 Btuh 6 1 NFRC 0.40, 0.60 No No S 2.0f1 1.0ft. 34.7 34.7 0.0 18 19 613 Btuh 7 1 NFRC 0.40, 0.60 No No E 2.0ft. 1.0ft. 78.6 7.8 71.0 18 48 3542 Btuh 8 1 NFRC 0.40, 0.60 No No E 2.0ft. 1.0ft. 52.0 8.6 43.4 18 48 2236 Btuh 9 1 NFRC 0.40, 0.60 No No E 2.011 1.Oft. 20.5 2.0 18.5 18 48 924 Btuh 10 1 NFRC 0.40, 0.60 No No W 2.0ft. 1.011. 21.7 5.7 15.9 18 48 867 Btuh Window Total 322 (sqft) 10211 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav /Sheath 1 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 407.0 2.2 911 Btuh 2 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 365.0 2.2 817 Btuh 3 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 430.2 2.2 963 Btuh 4 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 559.6 2.2 1253 Btuh Wall Total 1762 (sqft) 3944 Btuh Doors Type Area (sqft) HTM Load 1 Wood - Exterior 20.5 13.8 283 Btuh Door Total 21 (sqft) 283 Btuh Ceilings Type /Color /Surface U-Value R -Value Area(sqft) HTM Load 1 Vented AttidLIght/Shingie/RB 0.032 30.0 /0.0 1979.0 1.08 2143 Btuh Ceiling Total 1979 (sqft) 2143 Btuh Floors Type R -Value Size HTM Load 1 Stem/Crawisp(Carpet)(v) 19.0 1979 (sqft) 0.6 1149 Btuh Floor Total 1979.0 (sqft) 1149 Btuh Zone Envelope Subtotal: 17729 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio CFM= Load SensibleNatural 0.40 15832 1.00 118.7 1959 Btuh internal Occupants Btuh/occupant Appliance Load gain 10 X 230 + 3500 5800 Btuh Sensible Envelope Load: 25488 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0 -Attic) (DGM of 0.294) 7505 Btuh Sensible Zone Load 32994 Btuh EnergyGauge® / USRFZB v2.8 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL MIAMI INTL AP INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 Whole House Totals for Cooling Sensible Envelope Load All Zones Sensible Duct Load Total Sensible Zone Loads Sensible ventilation Blower Total sensible gain Latent infiltration gain (for 58 gr. humidity difference) Latent ventilation gain Latent duct gain Latent occupant gain (10 people (c2 200 Btuh per person) Latent other gain Latent total gain TOTAL GAIN 26120 Btuh 7691 Btuh 33811 Btuh 0 Btuh 0 Btuh 33811 Btuh 4682 Btuh 0 Btuh 2562 Btuh 2000 Btuh 2800 Btuh 12044 Btuh 45855 Btuh 1. Central Unit 56500 Btuh 'Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U- Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half dosed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half dosed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) Version 8 EnergyGauge® / USRFZB v2.8 Page 3 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL AP INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 Windows Duct load July excursion for System 1 Excursion Subtotal: 632 Btuh 632 Btuh 186 Btuh Sensible Excursion Load 818 Btuh EnergyGauge® / USRFZB v2.8 Page 2 Residential System Sizing Calculation Summary Project Title: INTERIOR REMODELATION 41 NW 109 STREET MIAMI SHORES, FL 3/4/2012 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(7 ft.) Temp Range(L) Humidity data: Interior RH (50 %) Outdoor wet bulb (77F) Humidity difference(58gr.) Winter design temperature(MJ8 99 %) 50 F Summer design temperature(MJ8 99 %) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 20 F Summer temperature difference 15 F Total heating load calculation 21494 Btuh Total cooling load calculation 45855 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 262.9 56500 Sensible (SHR = 0.75) 125.3 42375 Heat Pump + Auxiliary(0.0kW) 262.9 56500 Latent 117.3 14125 Btuh Infiltration Total (Electric Heat Pump) 123.2 56500 WINTER CALCULATIONS Winter Heating Load for 1 Load component Load Load Window total 322 Window total 322 soft 3867 Btuh Wall total 1762 sqft 5258 Btuh Door total 21 soft 189 Btuh Ceiling total 1979 sqft 1261 Btuh Floor total 1979 sqft 1523 Btuh Infiltration 148 cErn 3265 Btuh Duct loss Sens. Ventilation 0 cfm 6132 Btuh Subtotal 0 21494 Btuh Ventilation 0 t. in 0 Btuh TOTAL HEAT LOSS Btuh Latent gain(infiltration) 21494 Btuh Summer Cooling Load (for SUMMER CALCULATIONS Load component Load Window total 322 soft 10842 Btuh Wall total 1762 sqft 3944 Btuh Door total 21 soft 283 Btuh Ceiling total 1979 soft 2143 Btuh Floor total 1149 Btuh Infiltration 119 cfm 1959 Btuh Internal gain 5800 Btuh Duct gain 7691 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 33811 Btuh Latent gain(ducts) 2562 Btuh Latent gain(infiltration) 4682 Btuh Latent gain(ventilation) 0 Btuh Latent gain(intemai/occupants/other) 4800 Btuh Total latent gain 12044 Btuh TOTAL HEAT GAIN 45855 Btuh 8th Edition EnergyGauge® System Sizing PREPARED BY: DATE: EnergyGauge® / USRFZB v2_8 FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: INTERIOR REMODELATION2 Builder Name: MERLO AND ASSOCIATES Street: 41 NW 109 STREET Permit Office: City, State, Zip: MIAMI SHORES , FL , Permit Number. Owner. Jurisdiction: Design Location: FL, Miami 1. New construction or existing Existing (Projects 2. Single family or multiple family Single - family 3. Number of units, if multiple family 1 4. Number of Bedrooms 1 5. Is this a worst case? No 6. Conditioned floor area (ft2) 777 7. Windows(132.8 sqft.) Description Area a. U- Factor. SgI, U =0.60 132.75 ft2 SHGC: SHGC =0.40 b. U- Factor. WA ft2 SHGC: c. U- Factor. N/A ft2 SHGC: d. U- Factor. N/A ft2 SHGC: e. U- Factor. N/A ft2 SHGC: 8. Floor Types (777.0 sqft.) Insulation Area a. Crawlspace R= 19.0 777.00 ft2 b. WA R= ft2 c. N/A R= ft2 9. Wall Types (1233.0 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1233.00 ft2 b. N/A R= ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types (777.0 sqft.) Insulation Area a. Under Attic (Vented) R =30.0 777.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 250 ft2 12. Cooling systems a. Central Unit Cap: 24.2 kBtu/hr SEER: 15 13. Heating systems . a. Electric Heat Pump Cap: 22.8 kBtu/hr HSPF: 7.7 14. a. . water systems Electric Cap: 40 gallons EF: 0.92 b. Conservation features None 15. Credits Pstat Glass /Floor Area: 0.171 Total As -Built Modified Loads: 29.39 PASS Total Baseline Loads: 34.94 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. I PREPARED BY. \ t rt 0 0 Review of the plans and E specifications covered by this A ~.� calculation indicates compliance gyp$ ,e with the Florida Energy Code. F Oa n. ak ; Before construction is completed DATE. 0\ 12. this building will be inspected for compliance with Section 553.908 Florida BUILDING OFFICIAL: \ hereby building, as designed, is in compliance with the certify Code. OWNER/AGENT. PAD DATE: DATE. - Compliance requires a roof absorptance test in accordance with NI104.A.4. 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 PROJECT Title: INTERIOR REMODELATION Bedrooms: 1 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 777 Lot # Owner. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: MERLO AND ASSOCIATES Rotate Angle: 0 Street: 41 NW 109 STREET Permit Office: Cross Ventilation: County: DADE Jurisdiction: Whole House Fan: City, State, Zip: MIAMI SHORES., Family Type: Single- family FL , New/Existing: Existing (Projected) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTL AP 1 51 90 75 70 149.5 56 Low FLOORS V# Floor Type Exposed Perimeter Wall Ins. R -Value Area Floor Joist R -Value Tile Wood Carpet 1 Crawlspace 137 ft 0 777 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar Deck V # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 819 ft2 0 ft2 Medium 0.96 Yes 0 18.4 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 777 ft2 Y N CEILING V# Ceiling Type R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 777 ft2 0.11 Wood WALLS / Cavity R -Value Sheathing Framing Solar V # Omt Adjacent To Wall Type R -Value Area Fraction Absor. 1 N Exterior Concrete Block - Int Insul 4.099999 162.75 ft2 0 0.75 2 S Exterior Concrete Block - Int Insul 4.099999 162.75 ft2 0 0.75 3 E Exterior Concrete Block - Int Insul 4.099999 453.75 ft2 0 0.75 4 N Exterior Concrete Block - Int Insul 4.099999 453.75 ft2 0 0.75 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 2 of 5 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DOORS V# Omt Door Type Storms U -Value Area 1 S Wood None 0.460000 20.5 ft2 WINDOWS Orientation shown is the entered, asBuilt orientation. / V # Omt Frame Panes Overhang NFRC U- Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N Metal Single (Clear) 2 N Metal Single (Clear) 3 E Metal Single (Clear) 4 E Metal Single (Clear) 5 N Metal Single (Clear) Yes 0.6 0.4 N 9 ft2 2 ft 0 In 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 3 ft2 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 78.58333 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 20.5 ft2 2 ft 0 in 1 ft 0 in HERS 2006 Yes 0.6 0.4 N 21.66666 2 ft 0 in 1 ft 0 in HERS 2006 None None None None None INFILTRATION & VENTING / V Method SLA — Forced Ventilation — Run Time CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Fan Watts Default 0.00036 734 6.30 40.3 75.8 0 cfm 0 cfm 0 0 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 15 24.2 kBtu/hr 726 cfm 0.75 sys#1 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 7.7 22.8 kBtu/hr sys#1 HOT WATER SYSTEM V# System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # — Supply — Location R -Value Area — Retum — Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 250 ft2 Attic 100 ft2 Default Leakage Interior (Default) (Default) % 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5 TEMPERATURES ProgramableX]Thermostat: Y Cooling [X] Jan pX Feb Venting [X] Jan [[�X]] Feb C Mar [[�X]] Mar [X] [X] [X] pr Cei ing Fans: May X] May L�J Jun iil Jul XC Aug LX] Sep [X Oct 7C Nov [X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5 1 FORM 1100A -08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 41 NW 109 STREET MIAMI SHORES, FL, PERMIT #: INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK �/ Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls NI 106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Floors NI 106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Ceilings NI 106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. / (/ Recessed Lighting Fixtures NI106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. % �/ Multi-story Houses NI 106.AB.1.2 Air barrier on perimeter of floor cavity between floors. ✓ Additional Infiltration reqts NI106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. I/ OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters NI112.AB.3 Comply with efficiency requirements in Table NI112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. / i/ Swimming Pools & Spas NI 112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads NI 112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems NI 110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section NI 110.AB. Ducts in unconditioned attics: R -6 min. insulation. HVAC Controls NI 107.AB.2 Separate readily accessible manual or automatic thermostat for each system. V Insulation NI104.AB.1 N1102.B.1.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. 3/4/2012 5:36 PM EnergyGauge® USA - FlaRes2008 Page 5 of 5 r�, BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI -DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 NOTICE OF ACCEPTANCE (NOA).---__ www.mIamidade.Eov/buildinecode Niagara Industries, Inc. 2540 NW 38th Court MAR 2 2 Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within, their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Titan Tankless Water Heater APPROVAL DOCUMENT: Drawing titled "Titan Electronic Tankless Water Heater " sheet 1 of 1, with no revision, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved" and required markings per national. registered testing lab, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes ball automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 08- 0813.09 and consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 10-0107.01 Expiration Date: September 25, 2013 Approval Date: March 10, 2010 Page 1 Niagara Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing titled "Titan Electronic Tankless Water Heater" sheet 1 of 1, with no revision, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E. "Submitted under NOA # 03- 0919.02" B. TESTS 1. Test report on Dielectric Voltage - Withstand and Grounding Continuity Test per UL- 499 of Tankdess Hot Water Heater, Models N -10, 42, 64, 75, 85, 100, 120, 160, 180 and 210, issued by MET Laboratories, Inc, dated 01/05/10, signed by Rick Cooper. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO) 2. MET Laboratories, Inc, Quarterly Follow -up Reports. E. MATERIAL CERTIFICATIONS 1. Niagara Industries Factory Follow -up Inspection Report, issued by MET Laboratories, Inc, Track # 28332, dated 01/04/10, signed by R.M. Lutz. 2. Certification Report and Follow -up Service Procedure on Niagara Industries' Tankless Hot Water Heater, Models: N -f/b 10, 42, 64, 75, 85, 100, 120, 160, 180 and C -flb 10, 42, 64, 75, 85,100 and 120, for L/N # 29580, issued by Applied Research Laboratories, dated 05/04/09, signed by 3 different inspectors. 3. Certification Report # 29580, dated 01/29/97 and revised 11/01/07 and Quarterly Follow -up Summary Report, dated 07/16/08, both issued by Applied Research Laboratories, signed by Luis Martinez. "Submitted under NOA # 03- 0919.02" F. STATEMENTS 1. Statement letter of standard compliance issued by Met Laboratories, Inc, dated 12/03 /09, signed by Rick Cooper. 2. Statement letter of code conformance dated 11/12/03, issued, signed and sealed by Manuel R. Cereijo, P.E. "Submitted under NOA # 03- 0919.02" i ice r r57JIgJ Carlos M. Utrera, P.E. Product Control Examiner NOA No. 10-0107.01 Expiration Date: September 25, 2013 Approval Date: March 10, 2010 E -1 4 1 NIAGARA INDUSTRIES INC. TITAN TANKLESS WATER HEATER THE HEATER INCORPORATES A HEATING ELEMENT HOUSED WITH IN A HEATER EXCHANGER, AN ELECTRICAL COMPONENT MONITORS THE TEMPERATURE OF THE WATER HEATER AT DIFFERENT FLOW RATES MAINTAINING A PRE SET TEMPERATURE ALLOWING THE USE OF CONVENTIONAL OR SINGLE HANDLE FAUCETS Masud R. Cerego, P.E. NUMBE 24477 9605 SW 19St Miami, M. 33165 MODEL MAX KW at 220 V VOLTS MAX AMPS a1 220 V N.120 11.8 KW 220V 54 . N. MO 10.8 KW 220V 49 N- 85 8.3 KW 220 V 38 N•75 7.5KW 220V 34 N'• 64 8.4 KW 220 V 29 N .42 4.2 KW 220 V 19 _'N.10 3.2 KW 110V 29 PRneucr REVISED .. 1101mAnx ,-- _ __ as0ompifgwia►drt7od a BIAMMCWk N0/0 -010 .a3 4s ,4yl %te Q8 ,d14 1. Heat Chamber 2. Float Cavity 3. F.C. Board 4. Resistor 5. Left Side 6. Front 7. Switch 8. Water Out 9. Water in r Cmod mu 4110.4 Niagara Industries Inc." 4120 N.W. 28th Street Miami Fla, 33142 Ph. 305- 876 -9010 /. Fx. 305- 876 -9030 'Titan Electronic Tankless Water Heater BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NO ) � k_ Niagara Industries, Inc. 2540 NW 38th Court Miami, FL 33142 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 +y ;, —_iiiww.miamidade.gov/buildinecode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Titan Tanirless Water Heater APPROVAL DOCUMENT: Drawing titled "Titan Electronic Tankless Water Heater " sheet 1 of 1, with no revision, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved" and required markings per national registered testing lab, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 08 -0813.09 and consists of this page 1 and evidence page E -1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 10-0107.01 Expiration Date: September 25, 2013 Approval Date: March 10, 2010 Page 1 1 Niagara Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing titled "Titan Electronic Tankless Water Heater" sheet 1 of 1, with no revision, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E. "Submitted under NOA # 03 -0919.02" B. TESTS 1. Test report on Dielectric Voltage - Withstand and Grounding Continuity Test per UL- 499 of Tankless Hot Water Heater, Models N -10, 42, 64, 75, 85, 100, 120, 160, 180 and 210, issued by MET Laboratories, Inc, dated 01/05/10, signed by Rick Cooper. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO) 2. MET Laboratories, Inc, Quarterly Follow -up Reports. E. MATERIAL CERTIFICATIONS 1. Niagara Industries Factory Follow -up Inspection Report, issued by MET Laboratories, Inc, Track # 28332, dated 01/04/10, signed by R.M. Lutz. 2. Certification Report and Follow -up Service Procedure on Niagara Industries' Tankless Hot Water Heater, Models: N -f/b 10, 42, 64, 75, 85, 100, 120, 160, 180 and C -f/b 10, 42, 64, 75, 85,100 and 120, for L/N # 29580, issued by Applied Research Laboratories, dated 05/04/09, signed by 3 different inspectors. 3. Certification Report # 29580, dated 01/29/97 and revised 11/01/07 and Quarterly Follow -up Summary Report, dated 07/16/08, both issued by Applied Research Laboratories, signed by Luis Martinez. "Submitted under NOA # 03- 0919.02" F. STATEMENTS 1. Statement letter of standard compliance issued by Met Laboratories, Inc, dated 12/03/09, signed by Rick Cooper. 2. Statement letter of code conformance dated 11/12/03, issued, signed and sealed by Manuel R. Cereijo, P.E. "Submitted under NOA # 03 -0919.02" E -1 410:A49".-7 18 lv Carlos M. Utrera, P.E. Product Control Examiner NOA No. 10-0107.01 Expiration Date: September 25, 2013 Approval Date: March 10, 2010 NIAGARA INDUSTRIES INC. TITAN TANKLESS WATER HEATER THE HEATER INCORPORATES A HEATING ELEMENT HOUSED WITH IN A HEATER EXCHANGER, AN ELECTRICAL COMPONENT MONITORS THE TEMPERATURE OF THE WATER HEATER AT DIFFERENT FLOW RATES MAINTAINING A PRE SET TEMPERATURE ALLOWING THE USE OF CONVENTIONAL OR SINGLE HANDLE FAUCETS Maaael R. CereliO, P.E. P.R. NUMBER 24477 9605 SW 19St Miami, Fl. 33165 ht0011 MAX KW at 220 V VOLTS MAX AMPS ot 220 V N-120 11.8 KW . 220V 54 ,• N•100 10.8 KW 220V 49 N -85 8.5 KW 220V 38 N•75 7.5 KW 220V 34 N'. 64 6.4 KW 220 V 29 N.42 4.2 KW 220V 19 'N•10 3.2 KW 110V 29 'RODUCT REVISED is comply* whit trHolds ti . ry tai ft Runcting Coos l A! /e-0/0 AM ON* tplmdNo 6 4B !.i /Y11Rr 3 i. Heat Chamber 2. Float Cavity 3. P.C. Board 4. Resistor 5. Leh Side 6. Front 7. Switch 8. Water Out 9. Water in Niagara Industries Inc. 4120 N.W. 28th Street Miami Fla, 33142 Ph. 305- 876 -9010 I Ex. 305- 876 -9030 Titan E2ectroni.c Tankless Water Heater Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 173319 Permit Number: PL -5 -12 -828 Scheduled Inspection Date: September 05, 2012 Inspector: Hernandez, Rafael Owner: SANCHEZ, VIVIANE Job Address: 41 NW 109 Street Miami Shores, FL 33168 -4314 Project: <NONE> Contractor: V&V PLUMBING INC Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1121360030290 Phone: (786)281 -9960 Building Department Comments PLUMBING WORK FOR KITCHEN REMODEL Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments September 04, 2012 For Inspections please call: (305)762 -4949 Page 7 of 33 Miami Shores Village Building Department RWMEWM-11 BYe _oo__s_e- oo- emom -avo 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 }s BUILDING Permit No. 'p L PERMIT APPLICATION Master Permit No. r /z °-5i/ FBC 20 Permit Type: PLUMBING OWNER: Name (Fee Simple Titleholder): 1// (A/ /� e s44 Cl Phone#: Address: Y� dal /09 51— City: f! /sue// SA Os2e5 State: Kt 0/24 D 4 Zip: ' 3 /b h Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: `(l A-` /O 9 57 City: Miami Shores County: Miami Dade Zip: 33/ d8 Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: V \i i ib nee `7-n C. Phone #: '4$b - 9ctivo Address: 1a /ix) st 5 a) City: JM i Q vn; State: 'F 1-, r i d A Zip: 331c17- Qualifier Name: Vi c.+o- P . C,c JC.i G Phone #: -7f5b- 'ZSI - 9 %13 State Certification or Registration #: C.K.- I'-i Zt l 2... Certificate of Competency #: , Contact Phone #: Email Address: Vn V Pi rice Wrc„ r . Cam DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 4S00 Square/Linear Footage of Work: 00 Type of Work: ❑Address < gAlteration ONew ORepair/Replace Description of Work: env/ gory, ODemolition *********************** ***** *********** Fees** *********: x+ x**** **** ****** ****+x•x *********** Submittal Fee $ Permit Fee $ / CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ � �® TOTAL FEE NOW DUE $ :10 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be api v a ' nspection fee will be charged. Signature ent The foregoing instrument . owledgel before me this day of i , 2012 , by CIM6 ll'dt C who is personally known to me or who has produced As identification and who died take an oath. Sign: Print: s /.. My Commission Ex7;. CHRISTINE MARIE MUNOZ, MY COMMISSION # EE04094$ o,, EXPIRES Docember06, 2014 (407. 4,.„, .. ** ** * * * *** *** * ** APPROVED BY S /viz_ Signature The foregoing instrument was acknowledged before me thisPC1 day of Mos) , 20 12_, by W e 1.. C,c G who is kersonally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Sign: Print: c)�SS cc, Ce v c1 c` My Co > > pi CA GARCIA Notary Pub5o, Side of Florida Commlaslon My Com itito F�Irys flu 21, 2015 Zoning Clerk Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 173320 Scheduled Inspection Date: September 05, 2012 Inspector: Perez, JanPierre Owner: SANCHEZ, VIVIANE Job Address: 41 NW 109 Street Miami Shores, FL 33168 -4314 Project: <NONE> Contractor: GS MECHANICAL INC Permit Number: MC -5 -12 -829 Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1121360030290 Phone: (305)450 -8238 Building Department Comments NEW EXHAUST FAN, TWO NEW GRILLS AND NEW 2 TONS UNIT L Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. September 04, 2012 For Inspections please call: (305)762 -4949 Page 8 of 33 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 �: ®_ =��® Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305)762.4949 BUILDING Permit No. OCA2: PERMIT APPLICATION Master Permit No. /.ZC fz " FBC 20 MAY 09Zir2 Permit Type: MECHANICAL OWNER: Name (Fee Simple Titleholder): , / 11/ 4 6 ewe � f (F p ) �,� � ��f% C/i� Phone #: Address: 4/ >t-/ U) C 0 / City: > /SC°5 State: �— Zip: 3 3/ (' Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: 4 1 kliAJ `o a c City: Miami Shores County: Miami Dade Zip: 3 3 / 6" i Folio/Parcel #: Is the Building Historically Designated: Yes Flood Zone: CONTRACTOR: Company Name: G6 M :V J C4 -- Phone# O S 4S-0 S Z3 f3 Address: 1 j� f �j e 0 tom-' u '1 City: ! "t 1 State: Ft_ zip: '3 3 SS Qualifier Name: ti LLk ,c144 Phone #: 3 D D ? C` f 9 State Certification or Registration #: C M C l 2-s 0 1 S Certificate of Competency #: Contact Phone #: 3 c L i 5 O - 3 ' Email Address: J o) e O I 18k ci Q L'& fro. DESIGNER: Architect/Engineer: Phone #: o-� Value of Work for this Permit: $ � Q ©0 Square/Linear Footage of Work: Type of Work: ❑Address Alteration UNew ❑Repair/Replace ❑Demolition Descrip4' n of Work: 1 s jC ST F U --VW 0 1JSUJ 6 j14 lc ecNvo 2 Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ D : ' ' $ Bond $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ TOTAL FEE NOW DUE $ lir Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN . ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition o th ' issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a ce /e of he notice of commencement and construction lien law brochure will be delivered to the person whose property is s . 'ect t e t e t. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspec ;'o w a rs 'n (7) days after the building permit is issued. In the absence of such posted notice, the inspection wil e 'pp e a r: i spection fee will be charged. N Contractor The foregoing ins owledged before me this The foregoing instrument was acknowledged before me this0 day of , 20 _, by , day of , 2012- , by �� ,y ,� OtatA who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: My C My Commission Expires: APPROVED BY (Revised 07 /10 /07XRevised 06 /10 /2009)(Revised 3/15/09) 1l Examiner Structural Review 1A Py44 . • ... . No l' _ ,; Coillutlda [� ' • g My omm. d'n es u pueimmission # EE 110420 na,i ' Boded Through National Notary Assn. •1 Zoning Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO ❑ ARHI Sheet Attached: YES ❑ NO ❑ Contract Attached: YES ❑ UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER AHU or PKG. UNIT MODEL # COND. UNIT MODEL # KW HEAT NOM TONS AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / EER/SEER YES NO REPLACING DUCTS YES NO YES NO REPLACING THERMOSTAT YES NO YES NO NEW 4 "CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: Phone: State Certificate or Registratt'' . Certificate of Competency N. Date: o % /03 //Z-- Signature (Qualifier's signature only) Ac #5627367 STATE OF FLORIDA • DEPARTMENT TFS RLII a Ri TON CONSTRUCTION INDUSTRY SEQ# L11061000400 _A:r. CH N!JMB[R M" S NB 06/10/2011 080439804 CMC1250165 The MECIDWICAL CONTRACTOR lamed below IS CERTIFIED TJhder the provisions of Chapter 489 FS. ;Eepiration. dates AUG 31,:.2012 SUAU, WILLIAM 0 3 MECNANICIAL, INC. 2140 SW 80 CT MIAMI FL 33155 -1258 RICK SCOTT .GOVERNOR DISPLAY AS REQUIRED BY LAW NEN LAWSON SECRETARY J 05/03/2012 13:32 3052647666 VIP INS PAGE 01 ACCORD DeTiiiikarrrn CERTIFICATE OF LIABILITY INSURANCE 05/03/12 THIS CERTIFICATE ISSUED AS A MATER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURES/SL AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. *ii iiiiiciatilloate holder la. an AIZMONAL !INSURED, the polloy(fes) must be endorsed. 'SUBROGATION'S WAIVED, sealed to the tones and conditions of the peaty, certain policies may require an endorsement A statement on this cerdfleste does not confer rights to the certificate holder in lieu of such endomementit). ammo' rain: Fr& Erm (305)2864666 4005E5S: grevIPIns•net eisuRaits MOO cOvaRAGE Fax (305)2644E66 iNsu$$$ A: AacEndant Commercial Ins. INSURER B: CastlePoMt Florida PRODUCER V.i.p Insurance Agency 1535 SW 87 Ave Miami, FL 33174 Phone (206)266-9666 Mum G8 Mechanical Inc 2140 SW 80 Ct 1 rill rani: Ntiemi, FL 33155- (305) 796-7256 P41101F...5 INSURER ik; INSURER E : INSURER F: (305)264-7886 COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: .--THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POludY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDMONS OF SUCH POLICES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTA 1_ 7YPE OF oisuRANCE .._._._ _ __ .. _ . i titre !AR 1 . PAM faum.IFF. . TLC!. EFF . POUCY um I * -GENERAL Isisuury V cossumciAL GENERAL LIABILITY __I i 1 CLAIMs-mADE WI OCCUR GL-37910-0 • • 1 1 A L D 17.1 GERI AGGREGATE LimiT APPLIES PER I POUGY__U.S.ERR:f . I h9c. - • • AuTOMOSILe ualcurt Ej ANY AuTO -- Au. OWNED ( • SCHEDULED AUTOS AUTOS El HIRED AUTOS LT I NON-OWNED 0 fl IMAHRELIAL7Wa floccuR 1. ExcesS 1 1 CLAIMSIADE _ -Ej DEO• I I_BETENTIONS WORKERS...COMPENSATION AND ImpLGYERs' LIABILITY YIN ANY pROPRIETORIPARTNER/EXECUTIVE _ oFFIGERimEmaER EXCLUDED? (Mandatory In Nt11 it see, mamba undar DESCRIPTION QF OPERATIONS diem NIA IVCP7801397000 07/20/2011 07/20/2012 09/01/2011 1 rDEICIIPTION CIF 11;ERATIONi / LOCATIONS / irei iGLES MrtestiatOR0101, Ada/Iona' enema SolaHuTe. Emoto—Innton IsInIndA101 MECHANICAL CONTRACTOR LUSTS OCCURRENCE $ 1.000,000.00 II 'TO RENTED 100,000.013 • .F.1011$.E.0.1.$AROPIdreme) MED EXP (Amens demon) $ 5,000.00 PsnsoNAL a sav ituURY $ 1,000,000.00 GENERAL AGGREGATE S 2,000,000.00 PRODUCTS - COMP/OP AGO 0 1,000,000.00 09/01/2012 E.L. DISEASE • EA EMPLOYE4 $ 100,000.00 firlaccWINOLE LIMIT I $ BODILY INJURY (Pet oaraon) WILY INJURY (Pet mould VeirectEggo Ast? • s EACH OCCURRENCE AGGREGATE iwarau,,,i.s... er_ I E.L. EACH ACCIDENT 1 $ 100.000.00 EL DI$EflSE - POLCYLIMITI S 500,000.00 CERTIFICATE HOWER CANCELLATION r • _ _ _. 1.. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES SE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISION& Miami Shoots Village 10050 NE 2 Ave Miami Shores, Fl 33138 _ ACORD 25 (2010105) QF auTrICR1ZE0 REPRESENTATIVE MARTA C. CARDENTEY 6 1988-2919 The ACORD name and logo am registered marks of ACORD usimitstiUmti LOCATION S MECHANICAL ST 2140 SW 80 CT 3315 MI DO NOT FOR ARO G S MECHANICAL INC WILLIAM SUAU PRES 2140 SW 80 CT MIAMI FL 33155 in&dh.dhhhAa.mlinhhhhhanha.,, A Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 ON k Inspection Number: INSP- 178079 Permit Number: EL -5 -12 -827 Scheduled Inspection Date: September 10, 2012 Inspector: Devaney, Michael Owner: SANCHEZ, VIVIANE Job Address: 41 NW 109 Street Miami Shores, FL 33168 -4314 Project: <NONE> Contractor: CPS ELECTRIC, INC. Permit Type: Electrical - Residential Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1121360030290 Phone: 305 - 607 -8221 Building Department Comments INTERIOR REMODEL, NEW A/C HOOK UP, WATER HEATER INSTALLATION AND 200 AMPS SERVICE REPAIR Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 173316. Dryer to have 4 wire cord. Water heater need's disconnect. Label panel. In use covers on all outside receptacles. September 07, 2012 For Inspections please call: (305)762 -4949 Page 28 of 35 Jan 09 2012 11:43AM HP LASERJET FAX p . 1 ASrORD- CERTIF LATE Of LIABILITY INSURANCE 1DATE (MMtDDNYTY) 1�9�2012 /9/2012 PRODUCER MENDLZ INSURANCE &'= 1�'t�CY�iL SaJC 508 E 49 ST HIALEAH FL 33013 305 769 4936 THIS CERTIFICATE IS ISSUED•AS ONLY AND CONFERS NO HOLDER. THIS CERTIFICATE ALTER THE COVERAGE AFFORDED A MATTER OF INFORMATION FIGHTS UPON THE CERTIFICATE DOES NOT AMEND, EXTEND OR BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAIC# INSURED C . p . S . ELECTHIai ZINC. 1600 N' 28 AVE MIAMI t FL 3312, I INSURER A: ASCENDANT UNDCR1 RITE S INSURER $: INSURER C: INSURER G. INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED •LOW HAVE8EE . ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY P•RfOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM DE. CONDI CAI OF ANY 3II• -RACT OR OTHER DOCUMENT WITH RESPECT TO WHICH TIOIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE. F :FAD LYTIHE PD; -TES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, E)CLUSION:i AND CONDITIONS OF SUCH POLICIES. AGGREGATE UMITSSHGN,i .YFRYEBEES/EIREDUCEDBYPAIDCLAIMS. ILISR AOU1 u`�:! 1 -+ =t.'' Lr PCL+LYNUMBER �I�Y OAir EFID TILE �y�_�I R pINYYi� LNATS A GENERAL X LIAIdILITY COAddEFeCL4LQENE7Ai LW 7� GL -35924 09/23/11 09/23/12 EP •Ii OCCURRENCE $ $1 0 0 4 0 0 0 P ET REt ThDD 1 $ $100,000 $ $5,000 $$1.000.004 $81,000,000 $ 81 ,000,000 CLMM$?.inSOE $� CC—_= MED EXP (Anyone person) X 500 DE PE?isoNAL &ADVINJURY GENERAL AGGREGATE PF+3OUCTS- COMP/OP AGO GENLAtipRE�GA"�ELWpITAPPLIES ' POLICY I :OT _ E AUTOMOB#LE W BLITY ANYAUT{7 ALL OWhEDAJ111C*$ SCHEDiFsEDAUTOS HIREDALITOS N0IWCMINE!}.tUTOS • . CCNBINED SINGLE LIMIT (EseccW®nt) BC IILYINJURY (Pa person) $ ROILY INJURY (Pe sa1dent} PROPERTY DAMAGE (P•ecc1dent} $ GARAGE Lt BIU Y ANYAUTO AUTO ONLY - EAACCIDENT $ OTYER THAN EAACC $ AUTO ONLY: AGG $ A EXCESS.UMBRELLA L ABIUIY OCCUR r7 CLAWL$6IA••>L EA.;H OCCURRENCE $ AC- 3REGATE $ DEDUCTIBLE RETENTION $ S $ WORKERSCOMPENBAT;OMANC EMPLOYERS' LIABILITY ANYPROPPoETIDVMWA1@R;O .F WC- 602230 06/02/11 06/02/12 WCSTATU- OTH. is 1 ToRYLQbpTS I I ER E.L EACH ACCIDENT $$1,000,000 $81.000.000 $ 81.000.000 OFFICER MCC MEV? Hy deacribs�dsr SPEC tAL FROVISION9 be ow E L DISEASE - EA EMPLOYEE E.L DISEASE - POLICY LIMIT DESCRIPTION OTHER OF OPERAT OHS I LOCATIONS it V II 1 ED i EX= iJ 3IrIE ADDED BY ENDORSEMENT 1 SPECIAL PROVISIONS ELECTRICAL WORE CERTIFICATE HOLDER CANCELLATIO VILLAGE OF A= SEORES 10050 NE 2 I- —APE MIAMI SHORES ,31 ., 305-756-8972 6 8 I SHOULD ANY OF) ABOVE DESCRIBED ROLICESBE CANC- ED BEFORE THE EXPIRATION DATE THEREOF, E ISSUING INSURER WILL ENDEAVOR MAIL 10 DAYS WRITTEN NOTICE TO TH ° • TIFICATE HOLDER NAMED TO THE IMPOSE NO • : TION OR LIABILITY OE ANY KIND UPON 3 REPRESENT UT FAILURE TO DO SO SHALL E INSURER, ITS AGENTS OR AUTHORIZED - S- ATNE I J .. ...�.. ACORD26(20Ov BI 0 ACO CORPORATION 1958 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit No. Master Permit No. IR MAY 09Z 2 Permit Type: Electrical OWNER: Name (Fee Simple Titleho�ldI_ / 1' U A- e S* Phone #: Address: ei K City: 111 1 I l2' S State: Zip: 3 I b Tenant/Lessee Name: Phone #:.305 60-7- 08/ Email: JOB ADDRESS: �t f ,LU f'o City: Miami Shores County: Miami Dade Zip: 3316 Folio/Parcel #: Is the Building Historically Designated: Yes Flood Zone: CONTRACTOR: Company Name: C PS E /&-cnn Address: /6. o Art,J City: frn C( Vet ( State: Qualifier Name: 61 L zee9U l'c°✓.E.2 State Certification or Registration #: C Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Phone #:3CL�rG3 41-"70 Zip: 3 /�- r' Phone #: OSG 3 KTS7 Q �� C' // © �O Certificate of Competency #: C O ® 0 0 (7 e..4 3 Phone#: Value of Work for this Permit: $ 1 r Type of Work: Address Description of Work: 300."-- OO o �— Square/Linear Footage of Work: Iteration ONew Zd ORepair/Replaacc -e ODemolition A 14/4 *m: ��x�x: x�x�xa��x ****x:x�**** * ***** * * ** *** ****** Fees* ***** *** *** ***�x�xx��x�x ******* Submittal Fee $ Scanning Fee $ Notary $ Double Fee $ Permit Fee $ CCF $ CO /CC $ Radon Fee $ DBPR $ Bond $ Training/Education Fee $ Technology Fee $ Structural Review $ TOTAL FEE NOW DUE $ 1W Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOTTFRS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the x►tice of commencement and construction lien law brochure will be delivered to the person whose property is subj t to a► en t. lso, a certified copy of the recorded notice of commencement must be posted at the job site for the first ins ectio is ► s' (7) days after the building permit is issued. In the absence of such posted notice, the inspection wi not b: ► ► o ► . pection fee will be charged. Si_nat- _«�ffif�.J Own r • gen The foregoing instrument was knowledged�before me this 0/ day of �r , 20 /2-, by t� UI A / 6 SionictiC day of who is personally known to me or who has produced who is person As identification and who did take an oath. NOT UBLIC: Signature C / / { Contractor The foregoing instrument was acknowledged before me thi Ili. ; , 20(2 by 01/ A ., .+its Sign Print: My Co 046946 pit FIRES December.06, 2014 (407) 398-0163 Florida Note rvIce.com APPROVED BY known to me or who has produced AV� as identification and who did take an oath. NOTARY PUBLIC: Sig Print: My Co M1LJON ROMERO EmrcemmissioN # EE136473 ta} y�� 03,2015 ' Discount Assao. Cb. *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** � Z ✓� P."1-1‘1/ fie' Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) * * * * * * * * * ** Zoning Clerk