RF-13-757Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 189214 Permit Number: RF -4 -13 -757 Scheduled Inspection Date: April 25, 2013 Inspector: Rodriguez, Jorge Owner: CARLO, JENNIFER Job Address: 157 NW 104 Street Miami Shores, FL 33150 -1239 Project: <NONE> Contractor: LATERAL CONSTRUCTION INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number (305)762 -1644 Parcel Number 1121360131380 Phone: (786)281 -3077 Building Department Comments REPAIR LEAK ON ROOF VALLEY ON ENTRANCE Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed ,01/ Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. April 25, 2013 For Inspections please call: (305)762 -4949 Page 15 of 49 a Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: / 1017 54. OT@MEVM1 APR i ? 2a13 FBC 20 Permit No. 4F1 5151 Master Permit No. ROOFING City: Miami Shores County: Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): 001 FFsit- Address: 54 Pi Phone #::- MM ri7 D4cat Fogg iZ City: /A47 SiArfi State: Zip: Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company Name: (ZIUCT ) Phone #: Address: /0905 AJkT er4 City: K&LoCE A,.4j b State: F,, Zip: 5 2 Qualifier Name: p Phone #: State Certification or Registration #: (Gc_ / 3 Z-1 1 II 3 Certificate of Competency #: Contact Phone #: Email Address: DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ 6i Square/Linear Footage of Work: Type of Work: OAddition UAlteration ❑New E epair/Replace Description of Work: g£Q4>/L t.E.A4K 0 A KOF iii4L4E7 Eiu C4AA2', ODemolition Color thru tile: ******* * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * *F * * * * * * * * *r *,, *** * *** ** * * * * * *** * * * * * * * *** * ** CJ« Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ l.U,�' ( (0 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. he absence of such posted notice, the inspection will not be approved a a reinspection fee will be charged. Owner or Agent The foregoing ins i ,isent was acknowledged before me this /0 day of / ,20/3 ,by ,NW eA2iA , who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: APPROVED BY S RUIZ MY CQMMISSIIIN •FF16t1143 EXPIRES: JAN 17, 2016 Bonded through 1st State Insurance Co . s . ctor The foregoing instrument was acknowledged before me this day of 7 ,20/3 ,by C4 .Lz who is personally known to me or who has produced as identification and who did take an oath. Plans Examiner Structural Review NOTARY PUBLIC: Sign: Print: 7/L4 My Commission Expir (Revised 5/2 /2012)(Revised 3/12/2012) XRevised 06 /10 /2009XRevised 3 /15 /09XRevised 7/10/2007) S RUIZ MY (°.OMMiSSIQN #EE160143 EXPIRES: JAN 17,2016 Bonded through 1st State Insurance Zoning Clerk IVI iami Shores V Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: Z. WI 'Z CAA. L D Date: 7 ` /f1J Property Address: 1,51- l0Li t 4 o S1AOCCd. Roofing Permit Number: Dear Building Official: I e-i M,1 A- ( ® certify that I am not required to retrofit the roof to wall connections of my building because: o The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00.1 Please attach -proof of ad vildrinitakatiqn. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he /she is the owner for the above property mentioned. Swom to and subscribed before me this Notary Public, Sate of Florida at Large • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Miami -Dade My Home My Home Show Me: Property Information Search By: Select Item ■ ® Text only CJ Property Appraiser Tax Estimator i Property Appraiser Tax Comparison 1.:3 Portability S.O.H. Calculator Summary Details: Folio No.: - 2136 -013- 1380 Property: 157 NW 104 ST Mailing JENNIFER A CARLO Address: 1 Living Units: 157 NW 104 ST MIAMI FL Adj Sq Footage: 33150 -1239 Property Information: Primary Zone: 0800 SGL FAMILY - 1701 -1900 SQ CLUC: 0001 RESIDENTIAL - SINGLE FAMILY Beds/Baths: 3/2 Floors: 1 Living Units: 1 Adj Sq Footage: 1,265 Lot Size: 9,150 SQ FT Year Built: 1941 $50,000/ $93,767 36 52 41 31 52 42 MIAMI City SHORES SEC 5 PB 10- Legal 47 LOT 17 & W1/2 LOT Description: 18 BLK 126 LOT SIZE 75.000 X 122 OR 19427- School Board: 0944 1096 4 COC $25,000/ $118,790 22363 - 3045 06 2004 1 Assessment Information: Exemption Information: Year: 2012 2011 and Value: $44,981 $44,981 2nd Homestead: $98,786 $98 809 Value: Value: ssessed Value: $143,767y $50,000/ $93,790 Exemption Information: Year: 2012 2011 Homestead: $25,000 $25,000 2nd Homestead: YES YES Taxable Value Information: Year: 2012 2011 Applied Applied Taxing Authority: Exemptmpti Taxable ion/ Exe Taxable on/ Value: Value: Regional: $50.000/ $93,767 $50,000/ $93,790 County: $50,000/ $93,767 $50,000/ $93,790 City $50,000/ $50,000/ $93,767 $93,790 School Board: $25,000/ $118,767 $25,000/ $118,790 Sale Information: ale Date: /2004 Page 1 of 2 ACTIVE TOOL. SELECT. w 1041$ ST' . Aerial Photography - 2012 My Home I Property Information 'Property Taxes I My Neighborhood I Property Appraiser 0 112 ft Home 1 Using Our Site 'Phone Directory 1 Privacy 'Disclaimer If you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at Weomaster. Web Site 2002 Miami -Dade County. All rights reserved. Legend M Property Selected Property Street Highway Miami -Dade County Water http: / /gisims2. miamidade .gov /myhome /propmap.asp 4/10/2013 Miami -Dade County, Florida ONE NOTICE OF AD VALOREM TAXES AND NON —AD VALOREM ASSESSMENTS v '"�, �n_,.. t��.. r a xt.::... k,.F ...�._<_„� �' MIAMI SHORES STORMWATER 45.0000 MIAMI SHORES SANITATION 705.5200 1.00 1.00 45.00 705.52 BILL REQUESTED BY BAC HOME LOANS SERVICING,LP MTGCO #:091 Combined taxes and assessments $3,309. %. Discount for November $3p7.49 ill IN I I 1111 * 0 3+ 1 2+ 1 1- 2 COMMENTS Your tax bill has been requested by the above noted mortgage service company for payment Florida law requires mortgage service companies to make early payment for maximum discount, if suffident funds are maintained in your escrow account JENNIFER A CARLO 15714W 104 ST MIAMI FL 33150 1 3 6- 0 1 3 - 1 3 8 0* 11- 2136-013 -1380 FOLIO NUMBER 157NWf1r, ST PROPERTY ADDRESS 0153521 if you no longer have an escrow account and are responsible for paying these taxes, you may detach this portion, mad or visit our office location rued on bad. Make check payable to Mani-Dade Tax Collector, 140 W. Flagler Street, Wand, FL 33130. Your payment must be made prior to December 1 to obtain maximum discount t fG DE,' t 36 52 41 31 52 42 MIAMI SHORES SEC 5 PB 10-47 LOT 17 &W1/2LOT 18 UK 126 LOT SIZE 75.000 X 122 20033 11213601313800 0000330989 00000000 0000000 0000000 02000 & HIGH - VELOCITY HURRICANE ZONES Florida Building Code Edition 2010 High Veiodty Hurricane Zone Uniform Permit Application Form. Section A (General Information Master Permit No. I Process No. Contractor's Name E d u r J._, (r .i .cz S Job Address ❑ Low Slop ❑ Asphaltic Shingles O New Roof Low Slope R 53- Ai tA) l0 .s-,1- ,4iPra c, s11�4 (.- ROOF CATEGORY 3 ❑ Mechanically Fastened Tile ( MortarFAdhes ST- BY , DATE le. • Metal Panel/Shin les • Wood Shing g: • Prescriptive BUR -RAS 150 ROOF TYPE ❑ Reroofing ❑ Recovering Repair • Ma ROOF SYSTEM INFORMATION lot Area (SF) Steep Sloped Roof Area (SF) Total (SF) 36 a. a. tu CD BL��G DEPT Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 0 LJ 0 c if (I) 2010 FLORIDA BUILDING CODE -- RESIDENTIAL Ad M 1 HIGH- VELOCITY HURRICANE ZONES 1 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System), Roof S y stem Manufacturer: �r v "i L /g�, 14C1().54 Y .S " C , Product Approval Number: a - i0 2 7. 06 r' (1'- 010 1.O.3 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): P1: 3' , 1 P2: 6 8 - / P3: 100. 7- Maximum Design Pressure Product Approval Specific System: Method of tile attachment: P O )7 f v ct w , cJ A e 5 i v€ Roof Slope: 3 :12 Steep Sloped Roof System Description Deck Type: ype Underlayment. Insulation: 1 twi CAtu . C iuy `��+ P`'`i .# cx- u) 4efr1J d ff 3c, j '?)t'e. o Fire Barrier: Ridge Ventilation? vU/,j • Fastener Type & Spacing: dhesive Type: ype Cap Sheet: Mean Roof Height: 42 I 2010 FLORIDA BUILDING CODE — RESIDENTIAL Roof Covering: r4r U,vJk•Po.r p,'Is/ Type & Size Drip dge: u 3'10411 m ,�, 1, zs „ vs, s s,w 44'.23 . HIGH - VELOCITY HURRICANE ZONES 44.24 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compared the values for Mr with the values from K. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (Pt:31. i x )..Z6 =i%. 14, Me. is 35 =Mr, 5.5x-6 Product Approval Mr 2/., (P2: `3. x c),. �`t3 = 11-0&))) ))) - = Mr2 t 3.4t i, Product Approval Mr (P3: i x A v . =28. 116) - M� 5.3 =M22.4 =N1,4,22..bi4 Product Approval M, 2/1. Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval Mr Mr Required Moment Resistance* Mean Roof Height --10. Roof Slope ,lr. 16' 20' 25' 30' 40' 2:12 34.4 36.6 38.2 39.7 42.2 3:12 31.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 36.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 'Must be used in conjunction with a List of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Pr S9.1 xI :ff56 =6 -j11 w: 0) -W: x cox 8.•_= FM: (P2 :c ,& l x 1: 4 .56 =j .2 x w:=96 bt ) - W • ! x cos 8.•- = Fn: (P3:1. ^1 x l: 4,56 =157)Tx w: =I tL. -W: x cos 8 :•= Ft3: Where to Obtain Information Description Symbol Where to find Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height 11 Job She Roof Slope 8 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance P Product Approval Required Uplift Resistance P, Calculated Average Tile Weight W Product Approval Tile Dimensions I= length w= width Product Approval All calculations must be submitted to the Building Official at the time of permit application. 2010 FLORIDA BUILDING CODE - RESIDENTIAL SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existin • amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting whit- n result in ; xtending the service life of the roof. (tip h 3 wn r /Agent's Signature Date Contractor Signature Revised on 7/9/2009 LD MIAMI C JNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.eov/building/ Clay Forever 6801 NW 77 Avenue, Suite 301 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Altusa "S" Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigers. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub - Category: Roofing Tiles Material: Clay Deck Tyne: Wood 1. SCOPE This new roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.U. in Pimienta, Honduras and distributed by Clay Forever LLC as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Altusa "S" Clay Roof Tile Trim Pieces Dimensions Length: 18 -3/4" Width: 10 -3/4" varying thickness Length: varies Width: varies varying thickness 2.1 SUBMITTED EVIDENCE: Test Agency American Test Lab of South Florida American Test Lab of South Florida IBA Consultants, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Test Product Specifications Description High profile, one-piece, `S' shaped single roll ASTM C 1167 clay tile with a nominal 2 -1/2 inch headlap. For adhesive set applications. Accessory trim, clay roof pieces for use at TAS 112 hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Identifier RT0426.01 -11 RT0706.01 -11 2397 -116 94-083 94-084 25- 7200 -1 Project No. 307025 Test #MDC -78 MTS 520649 Test Name/Report ASTM C 1167 Static Uplift Testing TAS 101 ASTM C 1167 Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 (Quick-Drive Screws, Battens) Wind Driven Rain TAS 100 Date 05/07/11 07/11/11 06/28/07 April 1994 May 1994 Feb. 1995 Oct. 1994 TAS 102(A) May 2000 NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 2 of 9 PRI Asphalt Technology, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. CLF -003 -02 -01 7161 -03; Appendix III 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 P0402 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations TAS 102 TAS 102 Wind Tunnel Testing TAS 108 (Nall -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Aerodynamic Multiplier 25 -7183 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 October 2001 Dec. 1991 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 March 1999 March 1995 February 1996 April 1996 December 1996 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 3.7 May be installed on slopes 7:12 and greater. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page, 3 of 9 4. INSTALLATION 4.1 Altusa "S" Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight W (Ibf) Length -I (ft) Width -w (ft) Altusa "S" Clay Roof Tile 6.5 1.56 0.9 Table 3: Restoring Moments due to Gravity - Me (ft-ibf Table 2: Aerodynamic Multipliers - A, (ft3) 3 ": 12" or less Tile 5 ": 12" X (ft3) 7 ": 12" or greater X (ft) Profile Direct Deck Batten Application Direct Deck Application Altusa "S" Clay Roof Tile Direct Deck 0.253 Direct Deck 0.28 Table 3: Restoring Moments due to Gravity - Me (ft-ibf Tile Profile 3 ": 12" or less 4 ": 12" 5 ": 12" 6 ": 12" 7 ": 12" or greater Altusa "8" Clay Roof Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 4.47 5.35 4.40 5.27 4.31 5.16 4.20 5.03 4.08 4.89 NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (Min 15/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Altusa "S" Clay Roof Tile 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 .#8 Screw 28.7 28.7 18.1 2 .#8 Screws 58.2 58.2 26.8 1 -10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 1 Screw with Altusa Clip (See c ip details) Altusa "S" Clay Roof Tile' 1 Screw with clip (at the head of tile) 187.1 187.1 N/A Altusa "S" Clay Roof Tile' 1 Screw with clip (at the water course of tile) 35.2 35.2 N/A 1. Screw must be installed in the inside nail hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Altusa "8" Clay Roof Tile Adhesive 29.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 5 of 9 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Altusa "S" Clay Roof Tile Polyfoam PolyProThi 66.54 Polyfoam PolyProTM 3815 Polyfoam PolyProT"" 52.055 4 Large paddy placement of 63grams of PolyProT"". 5 Medium paddy placement of 24grams of PolyProT". 6 Large paddy placement of 54grams of PolyProT'". Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Altusa ' S" Clay Roof Tile Mortar Set' 24.50 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved ". ALTUSA MADE IN HONDURAS LABEL FOR ALTUSA "S" CLAY ROOF TILE. (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 6 of 9 PROFILE DRAWINGS ALTUSA `S' CLAY ROOF TILE NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 7 of 9 CLIP DETAILS 2 -1/2" OVERLAP (COVERS PIN HOLE) SCREW IN THE INSIDE HOLE NEAREST TO THE HUMP OF THE TILE DECK CUP WITH ONE (1) SCREW ATTACHED TO DECK CUP NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 8 of 9 SCREW (HOLDS CUP ONTO DECK TILE BY ALTUSA ( YP.) CLIP DETAILS (CON'T) 21/2" OVERLAP (COVERS PIN HOLE) SCREW IN THE INSIDE NAIL HOLE NEAREST TO THE HUMP OF THE TILE CUP PLACEMENT DETAIL DECK 1 141° 1 3/4° 314° / / / / END OF THIS ACCEPTANCE NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 9 of 9 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF -ELK Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786)315 -2590 F (786) 31525 -99 www.miamidade.eov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: UnderRoofrM 2 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 07- 0720.01 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 11- 1027.06 Expiration Date: 09/21/16 Approval Date: 11/17/11 Page 1 of 3 ROOFING COMPONENT APPROVAL Cateeorv: Sub- Catesorv;. Material: Roofing Underlayment Rubberized Asphalt PRODUCTS DESCRIPTION: Test Product Dimensions Specification UnderRoof ' 2 39 %" x 66.7' rolls TAS 103 ASTM D 1970 MANUFACTURING LOCATION: 1. Fresno, CA EVIDENCE SUBMITTED: Test Agency Intertek Testing Services NA Ltd. PRI Construction Materials Technologies LIMITATIONS: 1 Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. UnderRoofrM 2 shall be installed in strict compliance with applicable Building Code. 3. UnderRoofTM 2 may be used in roof tile and asphalt shingle assemblies. 4. UnderRoofrM 2 shall be applied to a smooth, clean and dry surface with deck free of irregularities. 5. UnderRoofrM 2 shall not be applied over an existing roof membrane as a recover system but may be applied to underlayment base sheets as listed in this approval. 6. UnderRoofrM 2 shall not be left exposed as a temporary roof for longer than 180 days after application. 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofmg products. 8. UnderRoofrM 2 may be used with any approved roof covering Notice of Acceptance listing UnderRoofrM 2 as a component part of an assembly in the Notice of Acceptance. If UnderRoofrM 2 is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. Product Description Self-adhering reinforced membrane of rubberized asphalt with a polyester surfacing for use as an underlayment in sloped tile and asphalt shingle roof assemblies. Roof slopes of 2/12 -12/12 are acceptable as indicated by local codes and manufacturer's installation instructions. Test Identifier 3077464 -01 3077464 -02 3090131 RGM -023 -02 -01 Test Name/Report ASTM D 1970 TAS 103 ASTM D 1970/TAS 103 ASTM D 4798/TAS 103 e 08/23/06 08/23/06 08/23/06 05/16/07 NOA No.: 11- 1027.06 Expiration Date: 09/21/16 Approval Date: 11/17/11 Page 2 of 3 lo APPROVED ASSEMBLIES: Deck Type 1: Wood, Non - insulated Deck Description: System E(1): Base Sheet: 19/32" or greater plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626 compliant underlayments with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: • Begin at lowest point on roof deck. Peel back the release film and align the membrane on the lower edge of roof; pull the release film to peel back and apply membrane. • Roll lower edges and seams with a hand roller. Use flat broom, squeegee or weighted roller to help lay flat and ensure full adhesion of UnderRoofrM 2 to the anchor sheet. • Where back nailing is required for steep slope applications, back nail and cover nails by overlapping with the next sheet. Use acceptable fasteners such as approved nails and tin caps. Plastic caps are not acceptable. Contact GAF -ELK technical services for other approved fasteners. • Valley and Ridge applications: Begin at lowest point on valley or ridge, peel back the release film, center the sheet over the valley or ridge and press firmly into place. • End Laps must be a minimum 6" and Side Laps must be a minimum 4" in and properly aligned with the existing selvedge edge. • Install when temperatures are 45 degrees and rising, over clean, dry and smooth substrate. • Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current product control Notice of Acceptance and applicable building code. • Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to the lap areas. • UnderRoofrM 2 shall not be exposed for longer than 180 days after application. GAF Materials Corporation reserves the right to revise or alter the exposure time, not to exceed the preceding maximum exposure time. • Wherever the adhesive back comes in contact with polyester surfacing such as end laps, penetrations and flashing material must be set in a 1/8 inch toweling of LeakBusterTM Matrix 201 Premium SBS Flashing Cement made in accordance with ASTM D4586 - Type 1 or equal flashing cement. • UnderRoofrM 2 is acceptable in foam applied and mechanically attached tile systems • Consult manufacturer's installation instructions for complete installation requirements. Surfacing: Roof Tile and Asphalt Shingle Assemblies. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.: 11- 1027.06 Expiration Date: 09/21/16 Approval Date: 11/17/11 Page 3 of 3