Loading...
RF-13-945Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 190641 Permit Number: RF -5 -13 -945 Scheduled Inspection Date: June 19, 2013 Inspector: Rodriguez, Jorge Owner: SHOAF, JONATHAN Job Address: 103 NW 103 Street Miami Shores, FL 33150- Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1121360131580 Phone: 305 - 757 -2612 Building Department Comments REPLACE 40 BROKEN TILES Infractlo Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. June 19, 2013 For Inspections please call: (305)762 -4949 Page 9 of 38 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 10 3 LL w. ' 0 g Si 2f -r FBC 20 ( D Permit No. Master Permit No. ) 5 " S City: Miami Shores ` FoliolParcel #: 11 j i (DOt 1 S SC) Is the Building Historically Designated: Yes County: Miami Dade Zip: 33 t 3 f' NO 1/ Flood Zone: OWNER: Name (Fee Simple Titleholder): 9 DNA/ Apt) SLAZf Phone #: Address: JO 3- it /a 3 ,sr City: /mil / ca.,u, s� d y'-e1 State: rc zip: 33/3 Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company Name: €2 A q wD J1'L a N a Phone #: 3a.1'' IJ'/- 07 G / 2- Address: 1r"/ L) E 17 sr / City: Wl ' td but i liW (wt. ej State: ( Zip: 33/3F- Qualifier Name: JAS S IN O p✓ ✓ Phone #: State Certification or Registration #: e- 011 30 t Certificate of Competent #: c2f.7l�%OiiLl.. Contact Phone#: 1.S 7.1'I -- to / Z- Email Address: 0if#J 004 7.-e Ni 6....., "a"- •6 M DESIGNER: Architect/Engineer: hone#. Value of Work for this Permit: $ �� .-v Square/Linear Footage of Work: �O Type of Work: ❑Addition ❑Alteration ❑New tepair/Replace ❑Demolition Description of Work: { lQ o iSroAt) G/0 S /-//C 5 a i a Akedwirr Permit Fee $ CO /CC $ Radon Fee $ DBPR $ Bond $ Technology Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) w Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not bJ approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this day o ,20.0_, by dO te who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: r✓ �,�� � . , Print: °F PI W� My Commission Expires: APPROVED CATHERINE A. DUFFS is r Comm. Expires Apr 15, Commission #r FF 8417 Signature Contractor Th regoing in trument was acknowle ged before me this ® ,201 ,by jJA- /Ine 0 6bln who is pe zonally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: ans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Sign: Print: C =�7 `� r-' ! `� M C. _u of E..' s• CATHERINE A. DUFFY. 'Is Notary Punric - State of Fiorklo 41,4.; effh=44ineMai#1#5,4171: ,.om fission # FF 8411 ° Bonaea tar "n NatWest Clerk Master Permit No. Miami Shores Village Florida Building Code Edition 20 0 PP R, !\ � High - Velocity Hurricane Zone Unifo ,A _ - sat -.,_ ._., `Y DATE Section A General lifftirtnation Pr PT Contractor's Name p /4 0 4 Job Address ❑ Low Slope ❑ Asphaltic Shingles ❑ New Roof ❑ Reroofing Low Slope Roof Area (SF) ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal PaneIShingies ❑ Prescriptive BUR -RAS 150 ROOF TYPE hakes ❑ Recovering Repair ❑ s intenance ROOF SYSTEM INFORMATION SteepSIped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1111111=11•1111111 IWA1111111111111■11111 11111111111111111111111 M11111110.11111M1 rzsiumpliimmimi 11111 E�iiiiil•. EMI MIMI ■/ ///■ 15.34 2010 FLORIDA BUILDING CODE — BUILDING Owner's Notification Form HVHZ 2010 MIAMI-DOE COUNTY "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renaffing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums,. etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. m 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the buildin . itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, desi e . ey a Florida- licensed engineer or registered architect to eliminate the attic venting, venting shall not bevy Owner's /Agent's Signature:iftil= Contractor's Signature: AffitANIIII111 Property Address: Date: Permit Number: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH - VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR -RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles i ~A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other 8/0,4/iG. As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation 2010 FLORIDA BUILDING CODE — BUILDING 15.33 MIAMI. COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/building/ Clay Forever 6801 NW 77 Avenue, Suite 301 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Altusa "S" Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. MIAMI.DADE COUNTY APPROVED NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Sub - Category:, Material: Deck Type: Roofing Roofing Tiles Clay Wood 1. SCOPE This new roofmg system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.U. in Pimienta, Honduras and distributed by Clay Forever LLC as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Altusa "S" Clay Roof Tile Trim Pieces Dimensions Length: 18 -3/4" Width: 10 -3/4" varying thickness Length: varies Width: varies varying thickness Test Product Specifications Description High profile, one-piece, S' shaped single roll ASTM C 1167 clay tile with a nominal 2 -1/2 inch headlap. For adhesive set applications. Accessory trim, clay roof pieces for use at TAS 112 hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1 SUBMITTED EVIDENCE: Test Agency Test Identifier American Test Lab of South RT0426.01 -11 Florida American Test Lab of South Florida IBA Consultants, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing MIAMI-DADE COUNTY APPROVED RT0706.01 -11 2397 -116 94 -083 94 -084 25- 7200 -1 Project No. 307025 Test #MDC -78 MTS 520649 Test Name/Report ASTM C 1167 Static Uplift Testing TAS 101 ASTM C 1167 Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 (Quick -Drive Screws, Battens) Wind Driven Rain TAS 100 Date 05/07/11 07/11/11 06/28/07 April 1994 May 1994 Feb. 1995 Oct. 1994 TAS 102(A) May 2000 NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 2 of 9 PRI Asphalt Technology, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. CLF- 003 -02 -01 7161 -03; Appendix III 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 P0402 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations TAS 102 TAS 102 Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Aerodynamic Multiplier 25 -7183 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 October 2001 Dec. 1991 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 March 1999 March 1995 February 1996 April 1996 December 1996 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 3.7 May be installed on slopes 7:12 and greater. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 3 of 9 4. INSTALLATION 4.1 Altusa "S" Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Altusa "S" Clay Roof Tile 6.5 1.56 0.9 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf Table 2: Aerodynamic Multipliers - X (ft3) 3 ": 12" or Tess Tile 5 ": 12" A, (ft3) 7": 12" greater Battens A. (ft) Profile Battens Batten Application Direct Deck Application Altusa "S" Clay Roof Tile Battens 0.253 0.28 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf Tile Profile 3 ": 12" or Tess 4 ": 12" 5 ": 12" 6 ": 12" 7": 12" greater Battens or Direct Deck Altusa "S" Clay Roof Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 4.47 5.35 4.40 5.27 4.31 5.16 4.20 5.03 4.08 4.89 NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (Min 15/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Altusa "S" Clay Roof Tile 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 .#8 Screw 28.7 28.7 18.1 2 .#8 Screws 58.2 58.2 26.8 1 -10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 1 Screw with Altusa Clip (See c ip details) Altusa "S" Clay Roof Tile' 1 Screw with clip (at the head of tile) 187.1 187.1 N/A Altusa "S" Clay Roof Tile' 1 Screw with clip (at the water course of tile) 35.2 35.2 N/A 1. Screw must be installed in the inside nail hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft -Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Altusa "S" Clay Roof Tile Adhesive 29.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. MIAMI.DADE COUNTY APPROVED NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 5 of 9 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Altusa "S" Clay Roof Tile Polyfoam PolyProTM 66.54 Polyfoam PolyProTM 38.75 Polyfoam PolyProTM 52.055 4 Large paddy placement of 63grams of PolyPro TM. 5 Medium paddy placement of 24grams of PolyProTM. 6 Large paddy placement of 54grams of PolyPro TM. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Altusa "S" Clay Roof Tile Mortar Set' 24.50 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved ". ALTUSA MADE IN HONDURAS LABEL FOR ALTUSA "S" CLAY ROOF TILE. (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI-DADE COUNTY APPROVED NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 6 of 9 PROFILE DRAWINGS ALTUSA `S' CLAY ROOF TILE MIAMI DADE COUNTY APPROVED NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 7 of 9 TILE BY ALTUS (TYP•) CLIP DETAILS 2 -1/2" OVERLAP (COVERS PIN HOLE) SCREW IN THE INSIDE HOLE NEAREST TO THE HUMP OF THE TILE DECK CLIP WITH ONE (1) SCREW ATTACHED TO DECK CUP PLACEMENT DETAIL MIAMI•DADE COUNTY APPROVED CLIP NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 8 of 9 SCREW (HOLDS CLIP ONTO DECK) TILE BY ALTUSA (TYP.) CLIP DETAILS (CON'T) 2 1/2" OVERLAP (COVERS PIN HOLE) SCREW IN THE INSIDE NAIL HOLE NEAREST TO THE HUMP OF THE TILE CLIP PLACEMENT DETAIL DECK 1 1/4" 1 3/4" 3/4° GALVANIZED METAL CLIP END OF THIS ACCEPTANCE MIAMI DADE COUNTY APPROVED NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 9 of 9