RF-12-1826Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 181845 Permit Number: RF -10 -12 -1826 Scheduled Inspection Date: April 12, 2013 Inspector: Rodriguez, Jorge Owner: MOFFETT, ROBIN Job Address: 230 NE 101 Street Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Miami Shores, FL 33138 -2423 Phone Number Parcel Number 1132060134640 Project <NONE> Contractor: MFS ROOFING INC Phone: (305)383 -2280 Building Department Comments RE ROOF CEMENT TILE ONTO WOOD DECK Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 179344. Village property damaged during construction. Sidewalk must be replaced /repaired. NB April 11, 2013 For Inspections please call: (305)762 -4949 Page 10 of 12 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 181844 Permit Number: RF -10 -12 -1826 Scheduled Inspection Date: April 12, 2013 Inspector: Rodriguez, Jorge Owner: MOFFETT, ROBIN Job Address: 230 NE 101 Street Miami Shores, FL 33138 -2423 Project: <NONE> Contractor: MFS ROOFING INC Permit Type: Roof Inspection Type: Up Lift Report Work Classification: Tile Phone Number Parcel Number 1132060134640 Phone: (305)383 -2280 Building Department Comments RE ROOF CEMENT TILE ONTO WOOD DECK Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP - 179345. Village property damaged during construction. Sidewalk must be replaced /repaired. NB April 11, 2013 For Inspections please call: (305)762 -4949 Page 9 of 12 A -1 Engineering Inspection Services, Inc 7066 SW 44th Street Miami, FI 33155 Tel: 786- 326 -9877 Fax: 305 - 485 -9011 a1roofinspection@gmall.com LAB CERTIFICATION # 10- 0512 -01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor MFSROOFING, INC Job Address 230 NE 101 ST MIAMI SHORES FL Owner's Name FANNIEMAE Type of Tile CONCREit 77LE Permit # RF- 10121826 Date Installed 11/15/2012 Approximate Roof Height 24 feet Roof Pitch 5/12 Type of access to Roof OK Approximate Square Footage of Roof 23 ft 2 Date Tested 11/19/2012 Number of Tests 65 Testing Equipment: F.G.E. 100 Contact Name PAOLA LARA Required Testing Force 35 /bs Phone #..0.52,25/-067.7,,,,,,, LOCATION # OF TEST PASS L # OF TEST FAIL Corner 10 _ Tests L7 Pass 0 Tests Fail Perimeter 16 Tests Pass 0 Tests E Fail ' Field 33 Tests `I Pass 0 Tests ❑ Fail Ridge .m 6 Tests k Pass 0 Tests Fail Total 65 Tests k/I Pass - 0 Tests Fail IN ACCORDANCE W1TH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF NATURAL DISASTERS. Cordially REMBERTO CONTRERAS P.E P.E # 21522 A -1 ENGINEERING INSPECTION SERVICES INC_ CERTIFICATION NO 10- 0512.01 7066 SW 44th Street Miami, FI 33155 Telephone (786)326 -9877 ' Fax (305)485 -9011 A-I. Engineering Inspection Services, Inc 7066 SW 44th Street Miami, Fl 33155 Tel: 786-326-9877 Fax: 305-485-9011 a1roofinspection@gmail.com LAB CERTIFICATION # 10-0512-01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor MF5 ROOFING, INC Permit # __RF-1012.1826_ Job Address 230 NE 101 ST MIAMI SHORES FL Owner's Name FA1VNIE MAE Type of Tile CONCRETE TILE Date Installed 1.tyrsgslz, Approximate Roof Height 24 feet Roof Pitch 5/12 Type of access to Roof OK Approximate Square Footage of Roof 23 ft 2 Required Testing Force 35 lbs Date Tested 11/19/2012 Number of Tests Testing Equipment: FGE 100 Contact Name PAOLA LARA Phone # (3052 251-0677 SKETCH OF ROOF A -7- -r n-r v tr .r- r r Revised by r V 7066 SW 44th Street Miami, Fl 33155 — Telephone (786) 326-9877 ", Fax (305) 485-9011 NOTICE OF COMMENCEMENT A RECORDED COPT MUST BE POSTED Old TID3 JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 11'3206-013 -4640 STATE OF FLORIDA: COUNTY OF MIAMi- DARE: THE UNDERSIGNED hereby gives notes that Improvements will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1 111111 11111 1111 11111 11111 11111 ill CFI 2112R:::. 70 8 1 OR &t 28298 Pa' 2514; t1aa) RECORDED 10/03/2012 14124:22 HARVEY RUVINv CLERK OF COURT luau -DADE COUNTY, FLORIDA LAST PAGE Space above resented for use of recommng office a1 desori ti a et pro and street/address: 230 NE 101 STREET, MIAMI SHORES, FL 33138 MIAMI SHORES l'AMD PEt 10-70 W1/2 OF LOT 8 & LOT 9 BLK 34 28020 -2490 021212 2. Description of improvement: REROOF 3. Owner(s) name and address: I-kUERAL NATL MRTG ASSN AKA FANNIE MAE interest -jr! property.. 14221 DALLAS PARKWAY #1000, DALLAS, TX 75240 Name and address of fee simple titleholder 4: Contractors name, address_and phone number MFS ROOFING, INC., 14090 SW 144 AVENUE ROAD, MIAMI, FL 33186 305- 251 -0677 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number Amount Of bond 6. Lender's name and address 7. Persons within the State of Florida designated; by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida, Statutes, Name, address and, phone number. 8. in addttlon to himself, Owners designates the following person(s) to receive a Copy of the Lienor's Notice as provided In Section 713.13(1)(b), Florida Statutes. Name, address and phone number. 9. Expiration date of this Notice of Commencemer (the expfatlon date Is 1 year the date of recarcpng unless a different date Is spedned) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OFTHENOTICEOF COMMENGEMENTARE CONSIDERED IMPROPER- PAYMENTS UNDER CHAPTER 71 ART 1, SECTION 718.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS • • R PRO- A NO OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SrrE BEFORE THE FIRST INSP =. • . IF YO • ` .44. TO OBT FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECO a ING YOUR NOTi - COMM MENT. Si .( By prnt i ame DANIEL CIA /O{ryce VICE PRESIDENT MFS ROOFING, INC ed Officer/Director/Partner/Manager Prepared Eiy print Name PREPARED BY DANIEL GARCIA TitielOffice 14090 SW 144 AVENUE ROAD, MIAMI, FL 33186 STATE OF FLORIDA COUNTY OF MIAMI -DADE The foregoing Instrument was acknowledged before me this 30 day of SEPTEMBER By DAELGARCIA 17 Indfvtduaiy, ors AGENT for FEDERAL WATL MRTG ASSN AKA FANNIE MAE ❑ Personally known, or i roduced the following type of !den 2012 that the facts. 5 Pert • Signature of Notary PubIic: Print Name: (SEAL) 0 moo: /O% 1... ' d +.- _ G G {S5 # ppgA1 3 =0-= pi s Jart0 X20. • ILf L.' at l have read the foregoing and e best of my knowledge and belief. s) of Owner(s � jg +a,u s Authorized Officer/Director/Partner 12401-52 PA➢E$ 1029' BY Miami Shores Village Building Department ?0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 �B SING ow PERMIT APPLICATION FBC11- 20 P e r m i t No. -nnL g 2& ,e Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: 230 NE 10ISTREET Zip: 33138 City: Miami Shores County: Miami Dade Folio/Parcel #: 11-3206 -013 -4640 Is the Building Historically Designated: Yes OWNER: Name (Fee Simple Titleholder): Fannie Mae Address:6400 LEGACY DRIVE PLANO zip: 75021 City: State: TX Zip: Tenant/Lessee Name: N/A PhoPhone: 75 3 -7840 Email: ANDREW_S_WEINER @FANNIEMAE.COM NO )0( Flood Zone: Phone: 972-773-7840 CONTRACTOR: Company Name: MFS ROOFING, INC. Phone#: 305- 251 -0677 Address: 14090 SW 144 AVENUE ROAD City: MIAMI state: FL Zip: 33186 Qualifier Name: HECTOR ALVAREZ Phone#: 305 - 251 -0677 State Certification or Registration #: CCC1327902 Certificate of Competency #: Contact Phone# 305- 251 -0677 Email Address: MFSROOFING @YAHOO.COM DESIGNER: Architect/Engineer: N/A Phone#: N/A Value of Work for this Permit: $15,200.00 Square/Linear Footage of Work: 1,918 Type of Work: ❑Addition ❑Alteration ❑New epair/Replace Description of Work: RE -ROOF CEMENT TILE ONTO WOOD DE ❑Demolition *************00000*********** *0* Hatl++ R+ k*'u *sP** *a sR*** ***sR **dlsga******* *ast+** * *+k Submittal Fee $ Permit Fee $ CCF $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ TOTAL NBE NOW DUE $ it J' C7l 0 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDmONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to for r rst irtspe ___`h'. pection will not be app achment. Also, a certified copy of the recorded notice of commencement must be osted at the job site occurs even (7) days after the building permit is issued. In the abs notice, the and a j ' inspection fee will be charged. Signature Owner or Agent The forego instrument was acknowledged before me this 30 day of SEPT DANIEL GARCIA 20 _, by who is personally known to me or who has produced FL DRIVER'S LIC As identification and who did take an oath. The oregoing f SEPT who is personally DRIVER'S L Contractor nt was acknowledged before me this30 20 _, by HECTOR ALVAREZ known to me or who has produced FL IC as identification and who did take an oath. Structural Review (Revised 3 /12/2012)(Revised 07110 /07)(Revised 06110 /2009)(Revised 3/15/09) Clerk Fannie Mae® August 16, 2012 To: VILLAGE OF MIAMI SHORES 10050 NE 2 AVE MIAMI SHORES FL 33138 ATTN: BUILDING DEPT This letter confirms that the below listed Company is employed as an approved Fannie Mae vendor and has our approval to sign for permits and record Notice of Commencements on behalf of Fannie Mae for the below listed property. Should you have any questions, you can contact us at Andrew_S_Weiner@fanniemae.com. Approved Fannie Mae Vendor: MFS Roofing Inc Daniel Garcia, Vice President Fannie Mae Property Address: 230 NE 101 ST MIAMI FL 33138 Sincerely, uttii:v., iyttitrow S wt,,'na Ass Rohki Fqkiiiiit /416u- ANA VAZQUEZ MY COMMISSIONS EE157427 EXPIRES January 05, 2016 (407)3864183 FloridatlotwyServimion The foregoing instrument was acknowledged before me this (.p day of L" , by fraildv(PA.A1 es.e' . ( ignature of N ry P - State of Florida) (Print, Type, or Stamp Commissioned Name of Notary Public) Personally known XX OR Produced Identification Type of Identification Produced FannieMae Maint ance and Re I t Work Authorization DATE: Sep 26, 2012 PAGE: -1- ORDER NO: AR1208B003 PAY TO VEND PAY TO FANNIE MAE 1704162143 MFS ROOFING INC. 14090 SW 144AVERD MIAMI, FL 33186 TR139198X REGIONAL OFFICE: SOUTHWESTERN REGIONAL OFFICE 2916 0: REO A1208B0 SERVICER LOAN ID: 1742759357 PROPERTY ADD ESE 230 NE 101ST ST SERVICER NAME JP MORGAN CHASE BANK, NA SERVICER NO CONTRACTOR NA 131230079 MFS ROOFING INC. MIAMI, FL 33138 CO, ' RACTOR NO. 139198X TO: (NAME AND ADDRESS OF BROKER) JUUES REALTY LLC 1700 KENNEDY CAUSEWAY SUITE 130 NORTH BAY VILLAGE, FL 33141 You are authorized to contact on behalf of Fannie Mae for the following maintenance and/or repairs to the above property. Cost to perform each item may not exceed the amount authorized below without prior written ITEM 1 2 3 DESCRIPTION AMOUNT Structural - Other Maintenance - Interior/Exterior/Final Cleaning Structural - Roofing /Gutters TOTAL ORDERED ❑ payment ❑ payment ❑ Submit to escrow company below (fill in) for payment. escrow: (initials) Escrow Company Name Escrow Company Work Completed on Work Inspected on (Date) For Fannie Mae Use Only Prior Authorization (if any) Accumulated* For work exceeding $1,000: 1. Bids have been received and approved 2. Bids have been taken verbally. _ Approved ($15,200.00 (initials) (initials) (Fannie Mae Sales Ren) (Date) if total cost exceeds $3,000 two authorized signatures are required 2nd level: ❑ Supervisor ❑ Manager (Date) If total cost exceeds $15,000, Sales Review Committee Approval Required Sales review: (Date) I certify that I personally inspected the above item(s) and found all work completed in a satisfactory and workmanlike manner. Broker Signature Date FANNIE MAE FORM 1093 JAN 03 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 9/30/12 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: FEDERAL NATL MRTG ASSN AKA FANNIE MAE Property Address:230 NE 101 STREET Roofing Permit Number: Dear Building Official: 1 DANIEL GARCIA certify that I am not required to retrofit the roof to wall connections of my building because: w The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions Iorida Building Code (1994 SFBC) Signature DANIEL GARCIA Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Swom to and subscribed before me this 3°t day of SEPT 12 Notary Public, Sate of Florida at Large • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Pro `on: Folio 11- 3206 - 013 -4640 Property Address 230 NE 101 ST Owner Name(s) FEDERAL NATIONAL MORTGAGE ASSN CIO CHASE HOME FINANCE LLC Mailing Address 3415 VISION DR MAILCODE OH4 -7164 COLUMBUS OH 43219 Primary Zone 1000 SGL FAMILY - 2101 -2300 SQ Use Code 0001 RESIDENTIAL - SINGLE FAMILY Beds/Baths/Half 2/2/0 Floors 1 Living Units 1 Adj. Sq. Footage 1,436 Lot Size 8,625 SQ FT Year Built 1942 Legal Description MIAMI SHORES SEC 1 AMD PB 10 -70 W1 /20F LOT & LOT BLK34 LOT SIZE 75.000 X 115 OR 17435 -1721 1196 1 COC 25759 - 1840 06 2007 1 OR 28020 -2490 0212 12 Assessment Information.. Current Previous Year 2012 2011 Land Value crii.1 9 27 $107,502 wilding Value C $115,521 $116,253 Market Value $239,148 $223,755 Assessed Value $239,148 $223,755 Exemption'' Intorstatiotar',;; Current Previous Year 2012 2011 Homestead $0 $0 2nd Homestead $0 $0 Senior $0 $0 Veteran Disability $0 Civilian Disability $0 $0 Widow(er) $0 $0 Disclaimer: MIAMI -DADE COUNTY OFFICE OF THE PROPERTY APPRAISER PROPERTY SEARCH SUMMARY REPORT Honorable Pedro J. Garcia Properly Appraiser Aerial Photography 2012 Taxait Vain+ fin Current Previous Year 2012 2011 Exemption/Taxable Exemption/Taxable County $0 / $239,148 $0 / $223,755 School Board $0 /$239,148 $0 /$223,755 City $0 / $239,148 $0 / $223,755 Regional $0 / $239,148 $0 / $223,755 Inforr Date Amount Recording Book -Page Qualification Code 2/2012 $171,100 28020 -2490 Deeds to or from financial institutions 6/2007 $367,000 25759 -1840 Sales which are qualified 11/1996 $115,000 17435 -1721 Sales which are qualified 911990 $85,000 14704 -2243 Sales which are qualified The Office of the Property Appraiser and Miami -Dade County are continually editing and updating the tax roll and GIS data to reflect the latest property information and GIS positional accuracy. No warranties, expressed or implied, are provided for data and the positional or thematic accuracy of the data herein, its use, or its interpretation. Although this website is periodically updated, this information may not reflect the data currently on file at Miami -Dade County's systems of record. The Property Appraiser and Miami -Dade County assumes no liability either for any errors, omissions, or inaccuracies in the information provided regardless of the cause of such or for any decision made, action taken, or action not taken by the user in reliance upon any information provided herein. See Miami -Dade County full disclaimer and User Agreement at http:// www. miamidade .govinfo /disclaimer.asp. Property information inquiries, comments, and suggestions email: pawebmail @miamidade.gov GIS inquiries, comments, and suggestions email: gis @miamidade.gov Generated on: Sunday, September 30, 2012 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the tor. The owner's initial in the adjacent box indicates that the item has been explained. . Aesthetics- Worlananship: The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement men the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to the existing roof system.) . Common Roofs: Common roofs are those which have no visible delineation between neigh i o ring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing posa for and/or owner should notify the occupants of adjacent units of roofing work to be performed. . Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. This provides the option of maintaining �nce. . Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident e original roofing system is removed. Ponding conditions should be corrected. `• . Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in ce with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior f the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. ace;, designed by a Florida licensed engineer or registered chitect to eliminate the attic be required. Owner's/Agents Signature Date Con actor's Signa la Property Address Permit Number SECTION R4402.14 HIGH VELOCITY HURRICANE ZONES — UNIFORM PERMIT APPLICATION Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR -RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A, 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1.2.3.4.5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Notice Of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Section R4403, or If Applicable, RAS 127 or RAS 128 4. Other Component Notice of Acceptances 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Re- Roofing Only) 7. Any Required Roof Testing Calculation Documentation MCIEEMT71 OCT 022612 Y Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form BY:a -o Section A (General Information) Q Master Permit No Process No.7 }— 1E18)(0 Contractor's Name q, 4. Job Address (E to ( '. ❑ Low Slope ❑ Asphaltic Shinat ROOF CATEGORY ❑ Mechanically Fastened Tile Mortar /Adhesive Set Tile ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 15C ROOF TYPE Reroofing ❑ Recovering Miami Shores Village APPROVED BY FfertING DE IT aintehance ROOF SYSTEM INFORMAT O03LDG DEPT DATE SUMO' TO (t� LIANCE WITH ALL FEDERAL ow Slope Roof Area (SF) Steep Sloped Roof Ar (� F) Total F) STATE AND C l l R LES AND REGULATIONS Iql b SECTION B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■ ■M■■■■ ■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■•■■■ N■■■■■ ■■■■■ ■■M■ ■ ■■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■■■■■■ ■ ■■ ■ ■■■■■■■■■■■■■■■ pn om■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■ ■■■■■■■■■■■■■■■E iiMU MMOI■■ M ■■■■■■ ■ ■■■■■ ■M■■■■■■■■■■■■■■ ■M■ ■ ■ ■ ■ ■■■ ■ ■■ ■■ ■■■■■■■■■■■■ ■M■■■■■■■■ ■M■■■■■■■ ■■■■■■■■■■■■ I•■ M■■■■■■■■■ M■■ ■ ■ ■■■ ■ ■ ■M■■ ■■■■ ■■ ■■ ■ ■ ■■ ■ ■■ ■ ■■■■ ■ ■ ■ ■ ■ ■MEMEM■ .... ■M ■ ■ ■ ■ ■ ■ ■• ■ ■'I■ ■■■■■■ ■ ■ ■ ■■ ■■ ■ ■ ■ ■ ■■■ ■■■■ ■ ■■ ■■■■■■■■■■■■ ii■■■■■■■■■■■ M■■ ■AUMME ■ ■ ■M■ ■■■■ ■ ■M■■■ ■■ ■ ■■ ■ ■MM■ ■■■■■■■■■■■■ f•■■■■■■■■■■■■■•■ r■■■■■■■■■■■MMNI1■■■■ ■MM ■M■■■■■ ■■■■■■■■■■■■ I•■■■■■■■■■ M■■■• ■ ■ ■ ■ ■ ■■■ ■ ■ ■ ■■SWWM ■■■ ■ ■ ■■■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■__ -= JM■■■■■■■■■■■■L. ∎.TM■ ■■nr----- ��-- :1■■■ ■M■■ ■■■■ ■■■■ ■■■ M ■ ■ ■■■■■■■■■, ■■■■M■■■ ■ ■■ ■■_ ■n %� i■■■■ ■ ■ ■ ■■11■■■■■■■■■■■ ■ ■ ■ ■ ■ ■■ ■■■ ■■ ■■■■■■r t ;� ■ ■ ■ ■ ■ ■ ■ ■■■■ i... i ■ ■ ■ ■ ■ ■ ■ ■ ■1'1 ■ ■■ ■ ■ ■ ■ ■ ■ ■■ ■■■■■■■■■■■■■■■■■■ uil■■■■■■■■ .n■ ■■■■ ■■■ ■■■■ ■■ ■ ■b1■ ■■ ■■■■ ■ ■ ■■ ■■■■■■O ■ ■■ ■ ■ ■ ■■ ■■■■u■ ■r ■MUVO a■ ■ ■ ■ ■ ■ ■■ ■w ■■ ■■■■i ... ■■ ■■ ■■■>• ■■■■■■■ MMEMMIIMMEIMMWMUNNOAMMILMI 11111■1•I•■■I, IMMM..ii I ■■■■■■■ ■■■■ ■ ■MM■■■ ■■■r'a c uuuk ■iOMFUAMM ■ ■ ■■ ■■ ■ ■ ■■ ■NI►i ■ ■ ■■■i I P IMMEMM■■■ ■■■■■■■ ■ ■ ■Cf > ■ ■ ■11 ■MI lrr ■■ ■ ■■ ■ ■■■ ■ ■ ■ ■ ■ ■M ■11■■ ■ ■■MII Wfl •A■ ■ ■■■■ MEMEM12 ■M ■ ■ ■■■■■ ■Y ■■■ ■ ■ ■ ■■ ■ ■■ ■■ ■ ■■ ■■ ■■ ■LIIMM■ ■MI IR5l•1■■ ■ ■■■■■ ■ ■EnmiE ■ ■ ■ ■■■■ ■ ■ ■ ■ ■ ■!• ■ ■■ ■ ■ ■■■■■ ---- is ■ ■■■ ■ ■ ■ ■ ■ ■■ ■■■! M( 1■■■■■■■■■ M■■■■ PI■■■■■■■■ M■■■■■■■■■■■■■■■ ■I'1■ ■ ■■■ ■ ■■■M■ ■■■■■■■.....■■■■■■■ l'I 17■■ M■■■■■■ ''■ ■ ■■■■ ■M■ ■■ ■■■ ■i=1■■■■■■ ■■■■■ ■■■■■■■■■■■■■■■■■■■. IMMUNE= ■■■■■ ■[1 ■M..... ■11■■■■■■ ■■■■■ ■■■■■■■■■■■■■■■■■■■■ ri■■■■■■■■ ■■ ■■■■■■IL5MME ■ ■ ■■G• ■M ■M■ ■M ■ ■ ■M ■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■...... ■ ■ ■ ■ ■ ■ ■■ ■■I....u. ■ ■ ■ ■ ■■ ■■■■■■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■i u ■■■■■'•■ p ■■ ■ri ■ ■■■■■ii■■■m■d■ ■ ■ ■■ ■ ■ ■ ■■■ MIME ■ ■ ■ ■ ■M■■■■tV'■ ■■■■.in ■ MM■ ■ ■■■■■■iorici■■■■■■■■■■■■■■■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■Si i a iiimmilAMMEMMEMEMEMMEMOWAIMMENOMMEMMIMMEMM ■■■■■■■■■■■■■■■■■.■■■ rlm■■■ ■■■ ■■■ ■ ■ ■ ■ ■MMMM■■■■■■■■ ■ ■■■■■■■ ■■■■■■■a.... --' i■\ i■■■■ M■■■■■ ■M■■■■■■■■■■■■■■■■ ■M■■■■■ ■tt IMMEMM■■■HUMFAME■■■■■■■■■■■■■■■■■■■■■ MEMEMs■■■■■■■■■MME ixh VG ?" P4 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: , 111 i jl i1li73 d za Product Approval Number: /1-- 0.0,,s?/ 0 ea Minimum Design Wind Pressures, If Applicable (From RAS 127 or calculations): P1::S, iti, P2: N G 1 P3: 1. : Maximum Design Pressure Product Approval Specific System: i5. Method of Tile Attachment: J 1i r d t,/ r. %i ce / 2 Roof Slope: : 12 Steep Sloped System Description Deck Type: 4:` `qt/tiAtod ype Underlayment: Insulation: ire Barrier: Ridge Venti o ? 467-10 0JA Fastener Type & Spacing: Adhesive Type: Mean Roof Height: i' A Type Cap Sheet: Roof Covering: Type & Size Drips Edge: Ildtz9k5a4 0" l e� Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mrwith the values from Mr. If the Mrvalues are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P, c tiaix Awl-0 = t25) -Mg: = Mr, Product Approval Mr - ( x .%) - Mg: , = Mrz Product Approval Mt % , (173: x1=.)- M9�- Mr9 uct Approval Mt 1'7 Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below q Product Approval Mt e Mr Required Moment Resistance* Mean Roof Height -► Roof Slope jr 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 X 34.4 36.0 37.4 39.8 4:12 (\ 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used In conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" x 1: = x w:= ) - W: x cos d: - = Fr, Product Approval F' (P2: x 1: = x w:= ) - W: x cos 0: - = Fr2 Product Approval F' (P3: x 1: = x w:= ) - W: x cos 0: - = Fri Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier X Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance P Product Approval Required Uplift Resistance Fr Calculate) Average 111e Weight W Product Approval 111e Dimensions I = length w = width Product Approval All calculations must be submitted to the Bullding Official at the time of permit application. MIAMI DE COUNT` BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/bulW1ual SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or . material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or rial fails to meet the requirements of the applicable building code. This product is a . ed as descri , and has been designed to comply with the Florida Building Code including the Jhgh Velocity Hurricane Zone i e Florida Building Code. DESCRuP L21 ON: Capistrano Concrete Tile LABELING: Each unit shall bear a ► with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07- 1018.09 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.:11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12111 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Capistrano Concrete Tile Trim Pieces Dimensions L =17" W =12'I" Thickness ='/2" = varies w = varies varying thickness Test Specifications TAS 112 TAS 112 Product Description High profile concrete roof tile. For direct deck or battened nail -on applications. Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No.:11- 0321.03 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 2 of 7 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier PRI Asphalt Technologies ERPF- 001 -02-02 Redland Technologies 7161 -03 Appendix III Redland Technologies Letter Dated Aug. 1, 1994 Redland Technologies P09647 -01 Redland Technologies P0402 The Center for Applied 94 -083 Engineering, Inc. The Center for Applied 94 -084 Engineering, Inc. The Center for Applied 25- 7094 -(3, 6 & 9) Engineering, Inc. The Center for Applied 25- 7120 -(1 & 2) Engineering, Inc. The Center for Applied 25- 7183 -(3 & 4) Engineering, Inc. The Center for Applied 25- 7214 -(3, 4, &7) Engineering, Inc. The Center for Applied 25- 7804 -4 Engineering, Inc. Celotex Corporation 520111 -3 Testing Services Celatex Corporation 520191 -2 -1 Testing Services Walker Engineering, Inc. Calculations Test Name/Report TAS -112 Static Uplift Testing TAS 102 & 102(A) Wind Tunnel Testing TAS 108 (Nail-On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier ate Aug. 2006 Dec. 1991 Aug. 1994 Aug. 1994 Sept. 1993 April 1994 May 1994 Oct. 1994 Nov. 1994 Feb. 1995 March, 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 NOA No. :11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 3 of 7 3. LIMI'T`ATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3,5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Capistrano Concrete Tile 10 1.417 1.04 Table 3: Restoring Moments due to Gray Table 2: Aerodynamic Multipliers - A (ft) Tile Profile Tile 4 ":12" A (ft) 6 ":12" / A (ft') Profile Battens Batten Application Battens ' Irect Deck Applic - 'Ion Capistrano Concrete Tile Direct Deck 0.300 Direct Deck 0.277 Table 3: Restoring Moments due to Gray - Ma (ft -Ibf) Tile Profile 3":1r 4 ":12" 5 ":12" 6 ":12" Greater than T' :12" Capistrano Concrete Tile Battens Direct Deck Battens Direct Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.68 6.99 6.57 (175181) 6.44 6.73 6.28 6.56 6.10 6.38 NOA No. :11- 0321.03 Expiration Date: 10/05116 Approval Date: 05/12/11 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - M, (ft -lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19/32" plywood) Battens Capistrano Concrete Tile 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1 -10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails (Feld Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 2 -10d Ring Shank Nails' 33.1 48.1 45.2 1. Installation with a 4" tile headlap and fastemers are located a min. of 2W from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Capistrano Concrete Tile Adhesive 29.31 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. . Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Capistrano Concrete Tile Polyfoam PolyPro7°" 66.53 Polyfoam PolyProTM 38.74 3 Large paddy placement of 83grams of PolyProTM. 4 Medium paddy placement of 24grams of PolyProT". 4 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Capistrano Concrete Tile Mortar Set" 24.5 5 Tie -rite Roof Tile Mortar. NOA No.:11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 5 of '1 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or Iogo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". EAGLEfr' FLORIDA CAPISTRANO CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following. 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building tale in order to properly evaluate the installation of this system, NOA No.:11- 0321.03 Expiration Date: 14/05/16 Approval Date: 05/12/11 Page 6 of 7 PROFILE DRAWING 0004:00004. CAPISTRANO CONCRETE ROOF TILL END OF THIS ACCEPTANCE NOA No.:11- 032I.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 7 of 7 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) 3M Company 3M Center Building 0220- 05 -E-06 St. Paul, MN. 55144 -1000 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /peas SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as des « ••- • has been designed to comply with the Florida Building Code including the High Veloc ' urricane Zone of the Flon 'Wing Code. DESCRIPTION: 3 2- Component Foam Roof Tile Adhesive LABELING: Each unit sha • O.' 11 anent label with the manuf i ra ' ame or logo, city, state and following statement: "Miami -Dade County Product "Control Approved ", ess otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigers NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05 /10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2- Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF 1000 ProPack® 30 & 100 N/A N/A Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs. /ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3M 'M 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. / -1 F —W F'– 2' MS NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160. 2. 3M114 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3M1'M 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 MIAMI MADE COUNTY APPROVED NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 4 of 7 LABELING: All 3MTm 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY END OF THIS ACCEPTANCE MIAMI-DADE COUNTY APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 MIAMIDADE COUNTY DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as d has been designed to comply with the Florida Building Code including the High V ty Hurricane Zone of the " : da Building Code. DESCRIPTIO LABELING: Each unit s ► ear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA # 11- 0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Snb- Category: Underlayment Material: SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 olystick TU Plus underlayment (Surface Printing) anufacturing Locati Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 MIA•I•DADE COUNTY APPROVED Dimensions Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 60 mils thick Roll: 32'10" x 3'33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32'10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass- fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self-adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04 /05/12 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 PRI01111 PUSA - 005 -02 -01 PUSA- 018 -02 -01 PUSA -035 -02-01 PUSA- 033 -02 -01 PUSA - 055 -02 -02 PUSA -083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103 /ASTM D4798 & G155 TAS 110 /ASTM D4798 & D1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04 /05/12 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied . All side laps shall be a minimum of 3 -Y2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11- 1229.01 Expiration Date: 09 /13/16 Approval Date: 04 /05/12 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. IR-Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be leis exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exyosure Limitations (days) Polystick MTS MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro Winter haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, and Tile Pro may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR-Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 5 of 8 GENERAL LINIITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 0 0. 0 N CO 6 Roofing Tiles (6 Max. Per Stack) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 1229.01 Expiration Date: 09 /13116 Approval Date: 04 /05/12 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of T' /12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1(800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAMI.DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09 /13/16 Approval Date: 04/05/12 Page 8 of 8