Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-12-1050
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 179045 Permit Number: RF -6 -12 -1050 Scheduled Inspection Date: September 27, 2012 Inspector: Bruhn, Norman Owner: DIANA LARA, MARK CASTANO Job Address: 109 NW 95 Street Miami Shores, FL 33150- Project: <NONE> Contractor: LAURUS MANAGEMENT CORP Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number (786)360 -2530 Parcel Number 1131010240270 Phone: (786)338 -0440 Building Department Comments REPLACE TILE ROOF Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 174590. SEAL COUNTER FLAshing FASTENERS. JR September 26, 2012 For Inspections please call: (305)762 -4949 Page 38 of 43 y. ACB2 Engineering Inc. Testing & Engineering Services Certification of Authorization # 8131 Tel: 954 - 245.8976; Fax: 954.301.7776 5230 NE 18TH Avenue Fort Lauderdale, FL 33334 8/23/2012 Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Division, 10050 N.E. 2nd Avenue, Miami Shores, FL 33138 Client: LMC Roofing Test Date: 8/23/2012 Permit # RS- 6121050 P roperty Address: Lara Residence 109 NW 95 Street, Miami Shores, Fl Roof Pitch: Type of Tile: Roof Area: 3 in 12 Eagle Roof Tile 23.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro H 160 Field Instrument : IMADA Force Gauge 0 -100 Serial number: 243454 Test Location Perimeter Area: 10.00 sq Field Area: 13.00 sq No. of Corner: 13 Ridge Areas: 146 pcs Total Number of Tests Field Uplift Pull Test Test results 10 As per FBC 2010 Passed 13 As per FBC 2010 Passed 13 As per FBC 2010 Passed 15 As per FBC 2010 Passed Important: These laboratory results can change due to future weather impacts and /or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordially, ACB2 Engi (NOA 09- 1005.01) Anton) do, PE Fla. Re . No: 36466 ACB2 Engineering Inc. Engineering and Laboratory Services 5230 NE 18th Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245 -8976 Fax: (954) 301 -7776 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # 1CT C'/ ' /G5 DATE: INSPECTION AFFIDAVIT 1G /S15 111/(-7- J /C-% Z (Print name and cirde License Type) License #: cCC 057 2ey On or about licensed as a (n) Contractor / Engineer / Architect, FS 468 Building Inspector 2 Z7 Z , I did personally inspect the roof deck nailing and (Date & time) Seconda water b. m- ark at //7 9/' Alin gJ /r -- (Complete Job Site Address) Based upon that a ., !nation I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (I:7,AI / / / "l r Signatu State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this cV day of Notary Public, Sate of Florida at Large Cus►u_0S ✓' - '`� Ot F10rlda public - State 23' 2015 "'P• %'B'•• otCo Mites SeP =¢'1�» Commtsston # EE 128810 • • 'N' • c2 Com National Notary Assi ��� �I �,o, .�' Bonded Through *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Revised on 5/21/2009 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 B1 DING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: f Oc r&,/ W el City: Miami Shores County: Folio/Parcel#: JUL3 B Y:. 1 , FBC 20 Permit No.4? 6_1_)-1057) Master Permit No. ROOFING Miami Dade Zip: , Is the Building Historically Designated: Yes NO Or OWNER Name (Fee Simple Titleholder): Address: (9 i1/41 _ cis Flood Zone: Phone#: City: Oi/ln Tenant/Lessee Name: Phone#: Email: State:1 Zip: <53 1 ,6-) CONTRACT R: Company Name: )OWr S I'LjaMIT18�P, Phone#: "04 7� o I Address: 9 l CO f / 3 � �. Zip: 33 8 Phone#: State Certification or Registration #: � Certificate of Competency #: Contact Phone#: OS) c � . q City: 1k rate: 1 11111111M1111- IMF Qualifier Name: DESIGNER: Architect/E b. Value of W Type of Wor, Description of Address: Phone#: Square/Linear Footage of Work: 95 ®Alteration ONew ORepair/Replace ODemolition gip'- DA Color thru tile: * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ********** Fe p ********* ********* ******************* *** Submittal Fee $ Permit Fee $_� Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 'WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceed' y $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochu - be delivered to the person for the firs ection whi occurs seven (7) days after the building permit is issued. must be posted at the job site � sence of such posted notice, the whose properly is subject to attachment. Also, a certified copy of the recorded notice of co The foregoing instrument was acknowledged before me this 3) The foreg sing instrument was ac , owledged before me this .SO day of c 12/4 ' 20 L, by , day of d cd) , 20 /1_, by , who is persondlly known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print My Commissi .101.1 "f— Ex es: %%%%%%% Magaly Fonseca •, COMMISS ION #EE192081 % ' / EXPIRES: APR. 24, 2016 NOTARY PUBLIC: Sign: Print: My Commission Ex : I���11O1�'i "a °��`P�•� Magaly Fonseca COMMISSION #EE192081 . oFa . EXPIRES: PR. 24 20 ****a�x�e�a�a��xe�s�e�+x** +x ***1 as+�>1+* a� +e�4 ga ****e * *s ****, �**** s+ s�********�x�x****** **a�+�+x+Gk t *OR*Mt *An'�f ** APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06/10/2009)(Revised 3/15/09) One Information Way, Suite 225 Little Rock, AR 72202 501- 945 -4506 ® 800- 365 -4506 D Fax: 501- 945 -7718 www.tarcorooflng.com Ulises R. Wiltz LMC Roofmg and Inspections, Inc. 305 -254 -2424 305 - 468 -6311 Fax Ref; Diana Lara Residence 109 NW 95th St Miami Shores, Fl To whom it may concern, .ea11ARRIE July 27, 2012 The intent of this letter is to inform you that Tarco Representative, Raymond Lopez has reviewed the Tarco PS200 HT membrane underlayment for the property located at in 109 NW 95th St Miami Shores, Fl on July 27, 2012. Please accept this form of comunication certifying the areas of the installed underlayment are in fact Tarco PS200 HT underlayment membranes which are listed on Tarco's current MD Notice of Acceptance (NOA) # 11- 0912.04. Please feel free to contact me directly at (305)796 -2286 should I be of any further assistance. Thank you for supporting Tarco, Raymond Lopez RRO, RCI, CSI Field Technical Services Manager Tarco rlopez@tarcoroofmg.com From: Ulises R. Wiltz (urwiltz@me.com) To: magalyfonseca a)bellsouth.net; Date: Mon, July 30, 2012 11:17:28 PM Cc: Subject: Fwd: Tarco PS200 HT Labeling Begin forwarded message: From: Ray Lopez <rlopez@tarcoroofing.com> Subject: FW: Tarco PS200 HT Labeling Date: July 13, 2012 4:49:58 PM EDT To: urwiltz@me.com FYI Raymond Lopez RRO, RCI, CSI Field Technical Services Manager Tarco Mobile (305)796 -2286 rkvez@tarcoroofing.com Confidential Information: This email and any attachments may contain confidential and/or legally privileged information intended for the individuals) named above. If you are not the intended recipient, you are hereby notified that you should not review, use, disclose, distribute, or forward this email or any of its content. If you have received this email in error, please notify the sender immediately and delete /destroy any and all copies of the original email message. ----Original Message---- - From: Tigera, Alex (PERA) [mailto:AT045 @miamidade.gov] Sent: Wed 6/20/2012 1:25 PM To: Estopifian, Pedro (PERA); Ray Lopez; Acebo, Jorge L. (PERA); Walton, Charles (PERA) Cc: Shads Mohseen Subject: RE: Tarco PS200 HT Labeling Pedro, The label may be on the membrane alone, or it may be on the packaging alone, or it may be on both the membrane and the packaging. Thanks, Alex Tigera, Roofing Product Control Examiner Miami -Dade County Department of Regulatory and Economic Resources Product Control Section 786 -315 -2589 Phone http: / /us.mg205.mail. yahoo. com /dc/ launch ?. partner= sbc &.gx=1 &.rand= l2v9gbvmb5dn3 7/31/2012 786 -315 -2599 Fax www.miamidade.gov /development/ < http:// www .miamidade.gov/buildingcode/> "Delivering Excellence Everyday" Please consider your environmental responsibility before printing this e-mail or any other document. Miami -Dade County is a public entity subject to Chapter 119 of the Florida Statutes concerning public records. E -mail messages are covered under such laws and thus subject to disclosure. From: Estopifian, Pedro (PERA) Sent Wednesday, June 20, 2012 12 :56 PM To: Tigera, Alex (PERA); 'Ray Lopez'; Acebo, Jorge L. (PERA); Walton, Charles (PERA) Cc: 'Shaik Mohseen' Subject RE: Tarco PS200 HT Labeling Alex, Please clarify, do we need to see the labels on the wrapping and on the membrane or if the membrane is stamped that is good enough. Pedro A. Estopinan, Building/Roofing Section Supervisor Miami -Dade County Department of Regulatory and Economic Resources 11805 S.W. 26 Street Miami, Florida 33175 -2474 (786) 315 -2221 Phone (786) 315 -2907 Fax li ww. uiiauiivadc. guvibuiiuiug<l iiip: iiwww.ufiauiivauc.guvi "u1ug> "Delivering Excellence Every Day" P please consider the environment before printing this e-mail. From: Tigera, Alex (PERA) Sent: Wednesday, June 20, 2012 8:59 AM To: Ray Lopez; Acebo, Jorge L. (PERA); Estopiftan, Pedro (PERA) Cc: Shads Mohseen Subject RE: Tarco PS200 HT Labeling Mr. Lopez, Thank you for updating us on the current labeling change to your product. As the NOA states on page 10, "All membranes or packaging shall bear the imprint.." allowing that the packaging be labeled if the membrane is not. Please alert your hup: / /us.mg205.mail. yahoo. com /dc/launch ?. partner= sbc &.gx =1 &.rand= 12v9gbvmb5dn3 7/31/2012 Print Page 3 of 4 contractors to retain the packaging so that the inspectors may see it. If any building official or inspectors have any concerns they are more than welcome to contact us with any questions. Best regards, Alex Tigera, Roofing Product Control Examiner Miami -Dade County Department of Regulatory and Economic Resources Product Control Section 786 -315 -2589 Phone 786 - 315 -2599 Fax www.miamidadegov /development/ < http:// www .miamidade.gov/buildingcode /> "Delivering Excellence Everyday" Please consider your environmental responsibility before printing this e-mail or any other document. Miami -Dade County is a public entity subject to Chapter 119 of the Florida Statutes concerning public records. E -mail messages are covered under such laws and thus subject to disclosure. From: Ray Lopez [mail[o:rlpez @tarcoroofing.com] Sent: Tuesday, June 19, 2012 11:02 PM To: Tigera, Alex (PERA); Acebo, Jorge L. (PERA); Estopiitan, Pedro (PERA) Cc: Shack Mohseen Subject Tarco PS200 HT Labeling Dear Mr. Acebo and Mr. Tigera, This email is to inform you of a temporary change to the appearance of the Tarco PS200HT underlayment To provide our customers with a cost - effective underlayment, we have manufactured rolls without any printing on the membrane facer. However, we are installing equipment in our production line that will allow us to print identifying marks on the facer; we expect to have this capability in 5 -6 weeks. Thereafter, we will provide your office with a sample of such membrane. In the interim, we request that you notify the Miami Dade County Building Department's Roofing Inspectors and any other municipalities' necessary of this temporary change. Please also inform the concerned parties that the product is acceptable as long as there are identifying marks on either the membrane itself or the packaging, as specified on the first and last page of the Dade NOA No.11- 0912.04. We believe this would help eliminate any confusion at the jobsites at the time of inspections. Your prompt assistance in this matter is greatly appreciated. Raymond Lopez RRO, RCI, CSI Field Technical Services Manager Tarco Mobile (305)796 -2286 rlopeztarcoroofing.com http: / /us.mg205.mail. yahoo. com /dc/launch ?.partner= sbe &.gx =1 &.rand= 12v9gbvmb5dn3 7/31/2012 Confidential Information: This email and any attachments may contain confidential and/or legally privileged information intended for the individual(s) named above. If you are not the intended recipient, you are hereby notified that you should not review, use, disclose, distribute, or forward this email or any of its content. If you have received this email in error, please notify the sender immediately and delete /destroy any and all copies of the original email message. http: / /us.mg205. mail. yahoo. com /dc/ launch ?. partner= sbc&.gx =1 &.rand= 12v9gbvmb5dn3 7/31/2012 Miami-Dadet Department Electronic Application SYstem lrion 'Delivering Excellence Every Date" Roof Systan Mantdacttwe': At.9 Retrwri7.3 Notice of Acceigance Number (NOA): t /._ 034R O Minimum ; : = e" if Applicable (from RAS P1 :3.� ,.I0 `a•37 P3: X'91) (From the NOA Specific is as ar p:k crokii Roof Mean Height 101 ft. of Tile Attachmenti qeel air PAC/ � � a Pay-calt Alternate Method of Tile Attachment per NOA: WA' Drip Edge Size 8 Gauge: 3''.�rP �G Drip Edge Material Type: r d q y« Drip Edge Fastener Type: Hook Ship/Cleat gauge or e IN" ifs "acid, Miami S' Psi hserl „MI Deck Type: s/g " 14, ., Optional Insulation: N/A Optional Nallabie Substrate: 1stt `A Optional Nailable Substrate Attachment 11 i f Basesheet Type: 4 3 O JJ it Fastener Type for Basesheet Attachment I yei 215 14ciite Tl Undue (Cep Sheet ) Type: 1".'q Cep T.55.1.66 5 .a Tile Underlayment Attachment Method: cO4Lefeit Tile Profile: illag ZONING DEPT BLDG DEPT SUBJECT TO COMPLIANCE STATE ANn cn; ! ! ATIONS Conctd,o7; ie, M IAMI COUNTY. DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786)315 -2590 F (786) 31525 -99 www.miamidade.eov/nera Tarco Specialty Products, Inc. One Information Way, Suite 225 Little Rock, AR 72202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Cod DESCRIPTION: 30# ASTM Specification Felt, EasyLay, Fast90, PS2 , MS300, SS400, NR500"' LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09- 0824.06 and consists of pages 1 through 10. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI-DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 1 of 10 ROOFING COMPONENT APPROVAL Category: Roofing Sub - Category: Underlayment Material: Asphalt, SBS, Polyester SCOPE: This acceptance is for 30# ASTM Specification Felt, EasyLay, Fast90, PS200Hr, PS200mH, MS300, SS400 and NR500HT underlayments as manufactured by Tarco, for use with approved prepared roof assemblies as described in this Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. PRODUCTS DESCRIPTION: Product Dimensions 30# ASTM 3' x 72" rolls Specification Felt EasyLay 3' x 133' 4" rolls Fast90 3' x 36' rolls PS200Hr 3' x 66'8" rolls PS200m' 3' x 66'8" rolls MIAMI -DADE COUNTY APPROVED Test Specification ASTM D 226 Type II ASTM D 226 Type II TAS 103 ASTM D 249 ASTM D 6380 TAS 103 ASTM D 1970 ASTM D 1970 Product Description Asphalt saturated felt underlayment Sheet material comprising a polyester substrate coated with bituminous coating for use as an underlayment in roofing applications. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 tile underlayment cap sheet. Granular surfaced, asphalt - impregnated organic felt reinforced, bituminous sheet material with a self - adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile roofing underlayment. Fabric surfaced, fiberglass reinforced, SBS modified bituminous sheet material with a self - adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile and metal roofing underlayment. Film surfaced, fiberglass reinforced, SBS modified bituminous sheet material with a self - adhesive bottom layer, for use as an underlaymebnt in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 2 of 10 MS300 SS400 3' x 66'8" rolls 3' x 33'4" rolls 3' x 66'8" rolls 3' x 33'4" rolls NR500m' 3' x 66'8" rolls MANUFACTURING LOCATION: 1. Greencastle, PA 2. Belton, TX EVIDENCE SUBNIITTED: Test Aeencv Atlantic & Carribean Roof Consulting, LLC PRI Asphalt Technologies Trinity I ERD IRT -Arcon MIAMI•DADE COUNTY APPROVED ASTM D 1970 ASTM D 1970 ASTM D 1970 Test Identifier ACRC06 -013 TOT - 003 -02 -01 TOT - 029 -02 -01 TOT - 030 -02 -01 TOT - 041 -02 -01 TOT - 042 -02 -01 T3580.10.06 -2 T3580.10.06 T30160.08.09 -R1 T10550.07.08 T32530.08.10 T33190.08.10 T37610.07.11 IRT07 -0006 IRT 07 -0036 IRT08 -0002 Fine granular surfaced, fiberglass reinforced, bituminous sheet material with a self - adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle roofing underlayment. Smooth surfaced, fiberglass reinforced, bituminous sheet material with a self - adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. Film surfaced, non - reinforced, bituminous sheet material with a self - adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. Test Name/Report TAS 103 ASTM D226 Type II TAS 110, ASTM D249 & D 6380 TAS 110, ASTM D249 & D 6380 TAS 110, ASTM D226 Type II ASTM D4798 & ASTM G155 TAS 103 TAS 103, ASTM D6380 ASTM D1970 ASTM D4798 & ASTM D1970 ASTM D1970 TAS 103 TAS 114 -D ASTM D1970 ASTM D1970 ASTM D1970 Date 06/14/06 08/22/02 07/05/05 07/05/05 05/24/06 05/22/07 10/26/06 10/12/06 10/12/10 07/30/08 08/17/10 08/06/10 07/29/11 07/11/07 02/22/08 02/22/08 NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 3 of 10 GENERAL LIMITATIONS — 30# ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30# ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. INSTALLATION REQUIREMENTS — 30# ASTM SPECIFICATION FELT: 1. 30# ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofmg Contractors Associations (NRCA) when installing 30# Felt. 3. During installation of 30# Felt, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or applicable Building Code. GENERAL LIMITATIONS - EASYLAY: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. EasyLay shall be applied to a clean and dry surface. 4. EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional information. 5. EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather resistant covering. In general, on slopes less than 4:12, a double layer of EasyLay is recommended. Double layer application is best achieved by using 19" side laps, making sure the side laps are `shingled in' to shed water. 6. When installing EasyLay, the roof system must include proper ventilation. 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance. 8. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 4 of 10 APPROVED ASSEMBLIES - EASYLAY: System E(1): Deck Type 1: Deck Description: Anchor/Base Sheet: Fastening: Anchor sheet mechanically fastened to deck. Wood, Non - Insulated. Minimum 19/32" plywood or wood plank. One or more plies of EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet). Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt. INSTALLATION REQUIREMENTS - EASYLAY: 1. EasyLay shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyLay. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. EasyLay shall be acceptable for use with asphaltic shingles, wood shakes and shingles, quarry slate, tile and metal roofing assemblies. 5 Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyLay. 6. Place a full width piece of EasyLay, parallel to the eave (low) edge of the roof. 7. Unroll EasyLay 2 to 3 feet, with the lay lines facing up, and position the end of it to the edge of the eave and rake. 8. Install a few fasteners at the top, near the rake, and roll out the sheet to a maneagable length. 9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. 10. EasyLay shall be fastened with approved roofing nails and tincaps or approved capnails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. 11. When installing nails, apply so that the head of the nail is flush with the EasyLay surface, without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down. 14. Align the next roll over the preceding sheet so as to form a minimum 4" overlap. 15. Then install the just placed sheet, per instructions above. 16. The bottom of the second course of EasyLay shall lay on top of the first course so that any water will flow over the top of EasyLay. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 5 of 10 17. Apply subsequent sheets in the same manner, with 4" side laps and 6" end laps over the preceding sheets. 18. When the top course is reached, lap about 6" of EasyLay over the ridge. 19. Install EasyLay a minimum of 6" up any vertical surfaces. 20. Stagger the end laps a minimum of 18" from the preceding course. 21. After installing EasyLay on the field of the roof, install drip edge at the eaves (if used). 22. When applying EasyLay in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used, but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley lining material. 26. Apply a minimum 1/16" thick uniform layer of SBS trowel grade modified flashing cement to water proof areas of EasyLay where any cuts or tears have occurred. Seams or joints may require the application of an SBS trowel grade modified flashing cement. 27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. GENERAL LIMITATIONS — TARCO SELF ADHERED UNDERLAYMENTS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 40° F and rising. 4. Tarco self adhered underlayments shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 5. Tarco self adhered underlayments are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self adhered underlayments. 7. Tarco self adhered underlayments shall not be applied over a pre - existing roof membrane or system. 8. After installation of Tarco self adhered membranes, wait a minimum of 48 hours before roof loading of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 6 of 10 10. All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per manufacturer's requirements, not to exceed 6 -high, to the standard maximum roof pitch of 6 :12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. Slope Tile Staging Method Front View - Staged Tiles Side View - Staged Tiles 11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 12. EasyLay, PS200mu, MS300, SS400, and NR5001" shall not be left exposed as a temporary roof for longer than 30 days after application. PS200"T shall not be left exposed as a temporary roof for longer than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 13. NR500"T is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco self adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. If Tarco self adhered underlayments or the ASTM standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 15. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. MIAMI -DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 7 of 10 APPROVED ASSEMBLIES — TARCO SELF ADHERED UNDERLAYMENTS System E(1): Deck Type 1: Deck Description: Anchor/Base Sheet: Fastening: Membrane: Surfacing: System F(1): Deck Type 3: Deck Description: Deck Preperation: Anchor/Base Sheet: Fastening: Membrane: Surfacing: Anchor sheet mechanically fastened to deck, membrane adhered. Wood, Non - Insulated. Minimum 19/32" plywood, wood plank. One or more plies of ASTM D226 Type II, ASTM D2626, or EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet only). All Tarco self adhered membranes applied to approved Anchor/Base Sheet. (See #15 below for back nailing) Approved Roof Assemblies as specified below. Membrane self - adhered to concrete deck. Concrete, Non - Insulated. Structural concrete or concrete plank min. 2500 psi. The concrete deck shall be clean and dry and cured for a minimum of 28 days. None Membrane shall be back nailed with approved concrete fasteners and 15 /8" approved tin caps at a maximum spacing of 9" o.c. at the head laps and be covered by the preceding layer. No back nail fasteners or tin caps shall remain exposed. Tarco PS200HT self adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS — TARCO SELF ADHERED UNDERLAYMENTS: 1. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofmg practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing Tarco self adhering underlayments. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. Fast90 and PS200' shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles, wood shakes and shingles, and slate or simulated slate roof assemblies. PS200mu and NR500' shall be acceptable underlayments for asphaltic shingles, wood shakes, shingles, and metal roof panel assemblies. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of the Tarco self adhering underlayments. 6. Tarco self adhering underlayments shall not be adhered directly over any pre - existing roof membrane. MIAMI.DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 8 of 10 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer, water based acrylic or water based polymer modified primer. 9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application. 10. Place the underlayments over metal drip edge in accordance with RAS 111. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the underlayment, working from the center of the material continuously to the ends of the sheet (half of the length of the sheet is the center); taking care to avoid wrinkles and ridges. 13. Remove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately. After some time, it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 guage 11/4" approved ring shank type applied with a minimum of a 15 /8" approved tin cap or approved capnail as required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 9" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas "side laps, end laps, T-joints" to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply 1 /8" thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive / flashing cement throughout the contact area of the 6" granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed, the membrane must then be hand rolled in place in order to ensure contact of membrane and achieve a minimum of 1 /8t" asphaltic bleed out in designated area. 18. Tarco self adhering underlayments shall be applied to protrusions, slope changes, valleys, curbs, and other roof top penetrations before any other sections of the roof. 19. When applying underlayments in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. 20. For ridge applications, center the underlayment and roll from the center outward in both directions. 21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 22. All protrusions or drains shall be initially taped with a 6" piece of like kind membrane. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. MIAMI -DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 9 of 10 MANUFACTURER'S CONSIDERATIONS: 1. Fast90, PS200" , PS200"'i', MS300, SS400, NR500HT can be directly adhered to wood decks. Ensure that such application is in compliance with applicable Building Code. 2. For best results when adhering Fast90, PS20011T; PS200tL1u, MS300, SS400, NR5001ff directly to wood decks, surface may be primed with an ASTM D41 asphalt primer, water based acrylic or water based polymer modified primer. When using primer, follow the manufacturer's recommendation for `cure time' prior to application of Fast90, PS200" , PS200mu, MS300, SS400, NR500HT 3. When using Fast90 and PS200'iT in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended. 4. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY APPROVED END OF THIS ACCEPTANCE MIAMI.DADE COUNTY APPROVED NOA No.: 11- 0912.04 Expiration Date: 01/25/17 Approval Date: 01/19/12 Page 10 of 10 Miami snores v illage Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit No. gT IMOMEWIE-; La JUN 0J,25i2 B Y: Master Permit No. Permit Type: BUILDING ROOFING G h OWNER: Name (Fee Simple Titleholder): I Q n4 L. �-a ro, Phone#: Oa) ?SL/ at, 2 y Address. © l\4 9s vg- City: t Q ry) i� O( . State: Tenant/Lessee Name: Phone #: zip: 33 /SO Email: JOB ADDRESS: 1 O 1 t`--I (II S S City: Miami Shores County: Folio/Parcel #: t 1 — 310 / — Oa.C' - 0.1.7 Miami Dade Zip: 33 I SD Is the Building Historically Designated: Yes CONTRACTOR: Company Name: S Gf b1 /49q/ Oa) /aa pczcP State: 7./ Address: City: Qualifier Name: NO Flood Zone: Phone#:()) 9S7 ' 2V Zip: 33 t e9,4 State Certification or Registration #: C-CC, 6.57 c:20 / Certificate of Competency #: 6-9 6 9 9 Contact Phone #: S c2.5q--eaci2K Email Address: DESIGNER: Architect/Engineer: Phone #: Phone #: Value of Work for this Permit: $ A 4000 ®® Square/Linear Footage of Work: Type of Work: ❑Addition ] ❑ Alteratio�on P ❑New 'Repair/Replace Description of Work: RP1C.0 °Hn j i e. roe) p 25o& S F' ❑Demolition : x************ *:***x:******** ********: ** *Fees:n*********** ****** **** nix***************** * ** Submittal Fee $ Permit Fee $Q O O 1 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ RSF . (0_40 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exce ' ' ing $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law broc ' will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of comme' ' 'nt must be posted at the job site for the first inspection hich occurs seven (7) days after the building permit is issued. In sence of such posted notice, the inspection will' of be a oved a ,r a reins'ection fee will be charged. Signa I` 1� , 1! `_ _I ..1� Signature 0 er or Agent O tor The foregoing instrument was acknowledged before me this 6 The foregoin instrument as acknowledged before me this day of �c ole , 20 17. , by , day of J0 ',P , 20 /Z, by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission xpire ��,,,,,, ,.• 172 :4 Magaly Fonseca z?' *Ifit COMMISSION #EE192081 %- `iEXPIRES: APR. 24, 2016 *x►****x►x * ** * * * * ********* r, °iA ►t Witae i:** ►** * *** **x► **: ************* *m► xx► x►: xx►****: x: x*►x►x****x::x►x********** APPROVED BY 414 ‘-/.1 Plans Examiner Zoning NOTARY PUBLIC: Sign: Print: q 9flreCe My Commission Exp' es: oo1?0.f* Magaly Fonseca �„�COMMI�ION #EE192081 I EXPIRES: APR. 24, 2016 www.AARONNoTARreom Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 4-50/-0114-0216 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: CFN: 20120373448 BOOK 28125 PAGE 2578 DP1TE:05/25/2012 01:35:11 PM HA VEY RUVIN, CLERK OF COURT, MIA -DADE CTY THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement d ) /� tfL ,�Sppace above reserved for use of recording office 1. Legal description of property and street/address: /O! And 7 5 S1 wailhesli* efgFZ 33/' 2. Description of improvement 3. Owner(s) name and ad in property: a(2Ar Name and address of fee simple titleholder : A 4 .or' ...:� .. ,ne : V!IiT, /Ul.+abrer:fI %T J%r./ fJ /.T. 0411%'1-' 5. Surety: (Payment bond required by i'o m contractor, if any) Name, address and phon number: v J Amount of bond $ 6. Lender's name ress // 7. Persons within the State of Florida dsfsignated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes / Name, address and phone number: / fi 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number: N/A 9. Expiration date of this Notice of Commencement: he expiration date b 1 year from the data of rem unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERLY. A NOTICE OF COMMENCEMENT MUST BE RECO'{• • AND POSTED ON THE JOB SITE BEFORE THE OR RECORDING 1- N OF ■ •MM I EMENT. / ALEIM ! / L FIRST INSPECTION. IF Y. INTEND. • OBTAIN FINANCING, CONSULT WITH YOUR : ..5r; ■ " Signatures) f {. , • � r ed Ofc er/Director/Parmer/Managl J TP Sw / Prepared B l.. 'I 1 Al r .:I: P red ey 3/.0 M / L Print ame `kn/Y/11 *r TL1 P Nam � 2s/ f — Title/Office loriel;Ldlt Tdle/Ofice STATE OF FLORIDA COUNTY OF MIAMI -DADE t; 1E/ i merit was a�e�ry�wledged before me this ,2 V day of By ID Inds dlua!� Iyy,,Jor CI asj,`,� /��J for tPersonafly known, or 0 produced the following type of identification: Signature of Notary Public: Print Name: (SEA-) VERIRICATRON PURSUANT TO SECTION 9262&. FLORIDA !STATUTE& Under penalties of perjury, I declare that I have read the foregoing and that the stat it are • to t ri•. == of my knowledge and belief. Si By ,mo+•u Pace 3 3no a,.;f0 /-z ,flil!U It�it0�1 " horized Officer /Dir ector/Partner/Manager who signed above: TEQF FLORIDA, +UNTY OF DADE original on file In this oft e. rAP le 6 20 .._.i 8 HEREBY CERTIFY Act tine 1 regoin HARVEY RUVIN, CL K, of Circuit a,,= ounty C t its Deputy Cif rk / j OWNER'S A141F'1DAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: ' tarn; oat VIIlQ e Re: Owner's Name 1 a n a ka rct, Property Address I C q l 1 It) 15 S Roofing Permit Number Dear Ilona, uilding Official: I 1u certify that I am not required to retrofit the roof to wall connections of my building because: x IA The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. LiThe building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 Signature •f Prope Owner Diono LLco Print Name STATE OF FLORIDA COUNTY OF MIAMI -DADE Sworn to and subscribed before me this day of 'a-0 (1-C' , 20 1 (SEAL) dr "°•• Magaly Fonseca it tc;sCOMMISSION•EE192081 � =� EXPIRES: APR. 24, 2016 ----*V Person `lioArl.AArANOTARY.com or Produced Identification When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. C:'DOemnents and Settings 4tcI\My Documents \Statistic.Ompbs_2\Rmfing Affidavit Compliance- 92607Fi11abledoc My Home Miami -Dade County, Florida Property Information Map Aerial Photography - 2009 This map was created on 6/6/2012 10:53:05 AM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. 0 - ..- . 111 ft IAMI•DADE Summary Details: Folio No.: Property: Mailing Address: -- 109 NW 95 ST MARK CASTANO -DIANA L LARA 109 NW 95 ST MIAMI SHORES FL 33150- Property Information: Primary Zone: CLUC: Beds /Baths: Floors: Living Units: Adj Sq Footage: Lot Size: Year Built: Legal Description: 0800 SINGLE FAMILY RESIDENCE 0001 RESIDENTIAL - SINGLE FAMILY 2/1 1 1 1,480 8,418.50 SQ FT 1947 BONMAR PARK PB 17 -11 LOT7 &S1/2 OF LOT 6 BLK 5 LESS R/W FOR 95 ST LOT SIZE 74.500 X 113 OR 19480 -2872 01 2001 4 COC 23497 -0007 05 2005 1 Assessment Information: Land Value: Buildin. Value: Market Value: ssessed Value: 2011 $67,279 $123,610 $190,889 $190,889 2010 $67,279 $124,365 $191,644 $191,644 Taxable Value Information: School Board: 2011 Applied Exemption/ Taxable Value: $0/$190,889 $0/$190,889 $0/$190,889 $0/$190,889 2010 Applied Exemption/ Taxable Value: $0/$191,644 $0/$191,644 $0/$191,644 $0/$191,644 Sale Information: Sale Date: Sale Amount: Sale O /R: Sales Qualification Description: 3/2012 $223,000 Sales qualified as a result of examination of the deed Arepsred'by dad Retwatft Richard A. Golden, Esq. Bremer & Golden, P.A. 1175 RE 125 STI ET Suite 512 North Miami FL 3f3161 RTSC File #27-12P lPrarcelmNauotbers 11 -3102 -024 -0270 Warranty Deed This Indenture, Made day of March Thorsten Leighty and Kerby, his wife , 2012 An , Between of the County of BROW RD , State of Florida Mark Casten and Diana L. Lara, his wife granters, and whose sddhass ix 109' W.W. 95 STREET, MMAMI SHORES, FL 33150 of the Comty of Mt dI DR L1 , State of Florida ,grantees. Witness& that the enA}ITORS, far awl in oonsidezation of the aura of TEN DOLLARS ($10) DOLLARS, and other good and valuable won to GRANTORS ht hand paid by GLIMMER, the reoei*c whereof is baeby aclmawledgal, have glad, bargained and sold to the said GRANTEES and GRANTEES' helm meow= and assigns SoreveS the fe}towiog described land, situate,, Wag nod being in the Conns9 of MIA1dt -DADS State of Florida to wit Lot 7 and the South 1/2 of Lot 6, in Block 5, of Moamar Park, according to the Plat thereof, recorded in Plat Book 17, at Page 11, of the Public Records of Miami -Dade County, Florida; excepting therefrom a portion for Right-of-Way purpose mote particularly described as folltows Beginning at the Southwest corner of Lot 7, thence r'un South 89 °10' 28" along the South line of said Lot 7 for a distance of 88.30 feet, to the Point of Curvature of a circular curve to the left; thence run Northeasterly along the arc of a said circular curve to the left, having a radius of 25.00 feet, through a central angle of 90 °12' 08" for an arc distance 39.36 feet, to the Point of Tangency with the B ast line of said Lot 7; thence run North 0° 37' 24" East, along the East line of said Lot 7, for a distance of 6.57 feet, to the Point of Curvature of a circular curve concave . to the Northwest, having a radius of 20.00 feet, through a central angle, of 83° 13' 06" for an arc distance of 29.05 feet, to a Point of Tangency; thence tun South 83° 50' 30" West for a distance of 96,40 feet, to the Southwest Corner of said Lot 7 and the Point of Beginning. and the grantors do hereby fay waaet die title to said land, and will defend the same against lawful claims of all persons wbomsoevtt: nmeem112ataoas01s,,mm sm, 2012 (BO)7O-S5 s >rzwna Warranty Deed - Page 2 Par dmNumber 11.- 3101 - 024 -0270 Yn Wiheaas WhereoZ the seam have becesamo set their beads and seals the day and year first above minim and delivered In our presence gie ' 7. M Witness as to 1.;777 t"" 7_ . Printed Name: Witness as to Thorsten °Vikor.t411 Thorsten Leigh P.O.Addresz593 Pigeon Phna' • , • FL33327 Printed ang • � Tike Kerby Witness as to ' P.O Addle= 593 Pigeon Nam Way, STATE OF Florida COUNTY OF BROMRD The fig Whim= was acknowledged before me Ibis Thorsten Leighty day of March heispereolally known to ale orhe has produced his Florida driver's license asides as <�y no�c * Vic' �.' * MY rrl' FXPIREA4pp Printed N 'kovRes Bonded Nu Y23, 2013 NotaryPv STATE -OF 0 0 rT vJee`' 31" 41 \t %At . COMMinianBXPiCCEC COUNTY OF The foregoing imam= was acknowledged be=es me this Tike Kerby March , 2012 by , 2012 by 27 -12p IffereaoaatedbyODbbaay Zm. 2012 (8(0)7 -593s P aPLWD -1 Section A w "Delivering Excellence Every Day" Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application For 0 azmnym; Section A (General Information) ,1I JUN 0 5 �� I Master Permit No: Process No: Contractor's Name: LMC ROOFING Job Address: (O9 i (,t) 95 54- ❑ Low Slope ❑ Asphaltic Shingles ❑ Sprayed Polyurethane Foam ❑ New Roof BY: Roof Category ❑ Mechanically Fastened Tile 121 Mortar /Adhesive Set Tile ❑ Metal Panel /Shingles ❑ Wood Shingles/Shakes ❑ Other: Re- Roofing Roof Type ❑ Recovering ❑ Repair Are there Gas Vent Stacks located on the roof? ❑ Yes I,No Roof System Information Steep Sloped area (ft.2) 2.5-0D 15 Total (ft.2) 2. S'OO f F Section B (Roof Plan) Low slope roof area (ft.2) 0 ❑ Maintenance If yes, what type? ❑ Natural ❑ LPGX Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width. a' Corner Size (a' x a'): 051 Miami Shores Village A R VED BY DATE DEPT ZONING BLDG DEPT �%� }� '44 a SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND cowrie RULES AND REGULATIONS Tile Roof$ystem "Delivering Excellence Every Day" Roof System Manufacturer: J q k Rcofiti � Notice of Acceptance Number (NOA): Q3R 1, D3 Minimum Design Wind Pressures, if Applicable (from RAS 127 or Calculations): P P2: ff27 P3: %'9D Maximum Design Wind Pressures, (From the NOA Specific system): 3?.7 psf Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Deck Type: Sg ii P14/60 Optional Insulation: I %A Optional Nailable Substrate: /A Miami -Dade County Building Department Electronic Application Section D Sloped System Description Tile Roof System Roof Slope: 3 Roof Mean Height "/12" rDr ft. fA,d of Tile Attachments lion, Pcidd Alternate Method of Tile Attachment per NOA: pa AI/4 Drip Edge Size & Gauge: 3" et .24, qG rviik (.,eta 1-14"45'al!j, Drip Edge Material Type: Drip Edge Fastener Type: Hook Strip /Cleat gauge or weight 1/4- Optional Nailable Substrate Attachment: N/A Basesheet Type: - 3 co i f 7 Fastener Type for Basesheet Attachment p./.5 ticii We-inlay:2 Tile Underlayment (Cap Sheet ) Type: 41ossTL' us Tile Underlayment Attachment Method: 5er9odloered Tile Profile: O 1 P/S ITQ CvvIc,thrr l 1 � l,Q� Section E 2, MIAMI•DADE COUNTY "Delivering Excellence Every Day" Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: P 2: P 3: r„ J x� - Mg: _ TAM - Mg: O.'7? = .�rJ - Mg: = Mr1: = Mr2: = Mr3: 43F.7 5 3g Method 3 "Uplift Based Tile Calculations Per RAS 127" NOA Mf NOA Mf NOA Mf For Uplift based tile systems use Method 3. Compare the values for P with the values for Fr. If the P values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. P1: P2: 1 1 xl: xl: P3:1 I x I: Description Design Pressure Mean Roof Height NMI X w: I x w: xw:1 =1 =1 =1 -W :l - W: - W: 1= =1 x cos 0: x cos 0: x cos 0: = Fr1: = Fr2: = Fr3: Where to Obtain Information to complete tile calculations Symbol Where to Find 5 NOA P 5 NOAP 5 NOAP P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. H Roof Slope 0 Aerodynamic Multiplier Restoring Moment due to Gravity Mg Job Site Job Site Product Approval (NOA) Product Approval (NOA) Attachment Resistance Mf Required Moment Resistance Minimum Attachment Resistance Mr P Product Approval (NOA) Calculated Product Approval (NOA) Required Uplift Resistance Fr Average Tile Weight W Calculated Product Approval (NOA) Tile Dimensions I = length w = width Product Approval (NOA) Owner's Notifi Cation Fortn MIAMI.OADE COUNTY "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roo ing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Flo i , 1 uilding Code, Building govern the minimum requirements and standards of the industry for roofing system i r ations. Additionally, the following items should be addressed as part of the agreement between the 1. Aesthetics-VVorkmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane owne e zontractor. The owner's initial in the adjacent box indicates that the item has been explained. are for the purpose of providing that the roofing system meets the wind resistance and water intrusion e orm. standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisi • s Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be a ' 'ed as part of the agreement between the owner and the contractor. 09( Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be ccordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida ode. (The roof deck is usually concealed prior to removing the existing roof system). ommon Roofs: Common roofs are those which have no visible delineation between neighboring nhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or ld notify the occupants of adjacent units of roofing work to be performed. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be below. The owner may wish to maintain the architectural appearance, therefore, roofing nail of the underside of the decking may not be acceptable. The Florida Building Code provides the opt', aintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural ress an ay require the review of a professional structural engineer. Ponding may shorten the life expec , ' d performance of the new roofing system. Ponding conditions may not be evident until the original roo ; , hem is removed. Ponding conditions should be corrected. erflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not m a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if ppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance rida Building Code, Plumbing. . Ventilation: Most roof structures should have some ability to vent natural airflow through the interior o the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additiona venting which can result in extending the service life of the roof. Owner's /Agent's Signature- Contractor's Signature: Property Address: Date: Permit Number: file: / / /CI /Documents %20and %20Settings /sky /Desktop /SECTION_1524[ 1 ].htm9/27/2007 5:46:06 AM !CAMS COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.aov/buildinal SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. • This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Capistrano Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07- 1018.09 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMI DADE COUNTY APPROVED NOA No.:11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions Capistrano Concrete L = 17" Tile W = 12 y" Thickness = Pieces 1= varies w = varies varying thickness M1AMIOADE COUNTY APPROVED Test Specifications TAS 112 TAS 112 Product Description High profile concrete roof tile. For direct deck or battened nail -on applications. Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No.:11- 0321.03 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 2 of 7 2.1 EVIDENCE SUBMITTED: Test AfZencv PRI Asphalt Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Celotex Corporation Testing Services Walker Engineering, Inc. MIAMIOAUE COUNTY APPROVED Test Identifier ERPF- 001 -02 -02 7161 -03 Appendix III Letter Dated Aug. 1, 1994 P09647 -01 P0402 94 -083 94 -084 25- 7094 43, 6 & 9) 25- 7120 -(1 & 2) 25- 7183 -(3 & 4) 25- 7214 -(3, 4, &7) 25- 7804 -4 520111 -3 520191 -2 -1 Calculations Test Name/Reuort TAS -112 Static Uplift Testing TAS 102 & 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier ate Aug. 2006 Dec. 1991 Aug. 1994 Aug. 1994 Sept. 1993 April 1994 May 1994 Oct. 1994 Nov. 1994 Feb. 1995 March, 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 NOA No.:11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (lbf) Length -I (ft) Width -w (ft) Capistrano Concrete Tile 10 1.417 1.04 Table 2: Aerodynamic Multipliers - A (ft3) Tile A (ft3) A (ft3) Profile Batten Application Direct Deck Application Capistrano Concrete Tile 0.300 0.277 Table 3: Restoring Moments due to Gravi - Mn (ft-lbf) Tile Profile 3 " :12" 4 ":12" 5 " :12" 6 ":12" Greater than 7 ":12" Capistrano Concrete Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.68 6.99 6.57 6.88 6.44 6.73 6.28 6.56 6.10 6.38 MIAMWADE COUNTY APPROVED NOA No.:11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19/32" plywood) Battens Capistrano Concrete Tile 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1 -10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nall (Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 2 -10d Ring Shank Nails' 33.1 48.1 45.2 1. Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft -ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Capistrano Concrete Tile Adhesive 29.31 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. . Table 6: Attachment Resistance Expressed as a Moment for Single Patty Adhesive Set Systems - Mf (ft -Ibf) Minimum Attachment Resistance Tile Profile Tile Application Capistrano Concrete Tile Polyfoam PolyProw 66.53 Polyfoam PolyProm 38.74 3 Large paddy placement of 83grams of PolyProTM. 4 Medium paddy placement of 24grams of PolyProTM. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Capistrano Concrete Tile Mortar Set° 24.5 5 Tile -Tite Roof Tile Mortar. NOA No.:11- 0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 5 of 7 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". FLORIDA CAPISTRANO CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system, M ECOUNTY APPROVED NOA No.:11- 032L03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 6 of 7 PROFILE DRAWING tiA02:140 ION CAPISTRANO CONCRETE ROOF TILE END OF THIS ACCEPTANCE MANMADE COUNTY APPROVED NOA No.:11- 032L03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 7 of 7 MIAMI. COUNTY DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.sov /sera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA # 11- 0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub - Category: Underlayment Material: SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Surface Printing) Manufacturing Location #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 MIAMI•DADE OUNTY APPROVED Dimensions Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65' x 3'3-3/8" Or 65' x 3' 60 mils thick Roll: 32'10" x 3'33/8" 100 mils thick Roll: 65' x 3'3-3/8" 80 mils thick Roll: 32'10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofmg membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass -fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofmg and roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test AHency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. APPROVED Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 PRI01111 PUSA- 005 -02 -01 PUSA- 018 -02 -01 PUSA- 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103 /ASTM D4798 & G155 TAS 110 /ASTM D4798 & D1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 -%2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. MIAM1•DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofmg, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS 114-Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, and Tile Pro may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR-Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMIDADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA' s, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4 "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAMIDADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 8 of 8 MIAM DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) 3M Company 3M Center Building 0220- 05 -E -06 St. Paul, MN. 55144-1000 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.sov /sera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2- Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMI-DADE COUNTY APPROVED NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves 3MTM 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofmg Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2- Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs. /ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Renort Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. / -1 F'— MS —W \2j MIAMI•DADE COUNTY APPROVED NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 4 of 7 LABELING: All 3MTM 2- Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nall through plastic cement Undertayment 1 Paddy (Beneath Tile) 10'In.' Faye Cone Fascia Eave Closure Eave course only: Keep adhesive approx. 41n. up from wespholes Nall through plastic cement Undedayment Paddy (Beneath Tile) 1) Place enough adhesive to achieve 17 to 23 Opt : 2x for square inches In contact with the pan tile stoop P h ap pgcationa 2) Tune covers upside down. Plate adhesive 112ln` / To 1 In. From outside edge of covertge. j Then Instagtlretile. \�..,,, 10 In. 21n. Underlayment 1 Nag through plastic cement Eave Course Eave Closure Eave course only Keep adhesive approx. 4In. up from weepholes Fascia MIAMI -DADE COUNTY APPROVED Remo top portion of the eave course covertile. Abutto second course of pan tiles. Ensure eave end of pan and cove:Wes are flush at save line. Eave closure (mortar shown) W ephole Fascia Sheathing Optional Point -up Mortar on longitudinal edges oftle NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nail through plastic cement Underlayment 1 Paddy (Beneath Tlle) 7 In. 11 Eave Course Eave Closure Nall through plastic cement 7 In\e� 21n. Fascia ,0. Weephole Eave closure Drip edge Underlayment Paddy (Beneath Tile) Eave Course Nall through plastic cement Underlayment Paddy (Beneath Tile) 7 In Eave Closure Eave Course Fascia NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement se;,* Paddy (between tile) Paddy (under tile) 3m. x3ln. Single paddy on under. layment Single paddy under tile Single paddy on top of tile ft 21n. X 71n. medium size paddy save Fascia course only Eave course Nall through plastic cement Nall through plastic cement Single paddy under tile Untierlayment Single paddy between tile 21n. x 71n. medium size paddy save course only rer 3 In.x 3 in. 4 In. Single paddy on under- layment Single paddy on top of tile Ewe Course Fascia Weephole Eave closure Drip edge Single paddy between the te- 3 In. x 3 In. Single paddy on underlayment Single paddy on top of tile Eave Course Eave Closure 21n. x 71n. medium size paddy save course only Fascia END OF THIS ACCEPTANCE MIAMI-DADE COUNTY APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7