RF-12-1939Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 181929 Permit Number: RF -10 -12 -1939 Scheduled Inspection Date: November 30, 2012 Inspector: Bruhn, Norman Owner: MINSKI, JOEL & ANDREA Job Address: 9969 NE 4 Avenue Road Miami Shores, FL 33138- Project: <NONE> Contractor: ISAACS ROOFING & INSULATION CORP Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number (305)510 -0916 Parcel Number 1132060171230 Phone: (305)234 -5234 Building Department Comments RE ROOF TILE TO TILE Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 180087. Cancelled by Allen November 29, 2012 For Inspections please call: (305)762 -4949 Page 10 of 13 Miami Shores Viiiage Building Department RE: Permit # 1C 12- — 1 q 31 INSPECTION AFFIDAVIT licensed as a (n) Contractor / Engineer / Architect, 1 (-0,,s2 z (Print name and circle License Type) License #: LCD- 13 ZS SSCoe On or about t 112– (Date & time) Secondary water barrier work at 91 (0q 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: f 2 P2--- • FS 468 Building Inspector , I did personally inspect the roof deck nailing and ACI, 71. (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he /she is the contractor for the above property mentioned. Swom to and subscribed before me this 6 Notary Public, Sate of Florida at Large day of LAUDIA V. CUBILLOS Notary Public - State of Florida 4 My Comm. Expires Sep 23, 2015 ,4 Commission # EE 128810 OF ,, Bonded Through National Notary Assn. 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Revised on 5/21/2009 i I 1111111 111111011 1111111111 11111 11111 1111101 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION R. PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: -N 2r;_s12R07S15.4-3 EI•; 28322 F'9 3710 tips) :ECORcEC 10/22/2012 10:03:18 ARVEY RUV'II'#r CLERK OF COURT IAIII -DAOE COMM FLORIDA AST PAGE STATE OF FLORIDA, CO' NTY OF LADE 1 HEREBY CERTIFY that this %° , e copy of the original filed in t! hire . d y of AD20 aMigicTiteti};ial . 3. THE UNDERSIGNED hereby gives notice that improvements will be _ j ; property, and in accordance with Chapter 713, Florida Statutes, the fol • ! Yg irif tra�6 is provided in this Notice of Commencement. By !C 1. Legal description of property and street / address: ctc, (� 10..0 ILVV-tes Q4AA; -6S- /-fir u_ nzy Courts 2. Description of improvement: 3. Owners) name and address: J ci4 eon 0".3E. A" �. Interest in property: Qt,J- r'C, ft— • Name and address of fee simple titleholder: 4. Contractor's name and address: 1`1225 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: 9. Expiration different d te •f this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a pecified) te is Sign - Owner Print Owner's Z c l_ kS ( Prepared by Sworn to and subscribe Notary Publi Print Notaxy's- Nafiie: My commission expire fore me t l 4 ,7 —1- day of 5P �1E. 20 /c -i..i4>, r,JR A S /N4, Address: * MY COMMISSION * DD 956783 EXPIRES: May 10, 2014 „„ no • 44 Bonded Tina Budget Nosy ar Servkes BUILDING Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 LOCT 1 ; 245i2 Jjji BY: o_oomvmmo.. —.e,.,00 FBC 20 Permit No. � 2� I PERMIT APPLICATION Master Permit No. Permit Type: BUILDING JOB ADDRESS: (Igo Phe 'Oa di-1) City: Miami Shores County: ROOFING Miami Dade Folio/Parcel #: Is the Building Historically Designated: Yes OWNER: Name (Fee Simple Titleholder): :SC-01— 6W1 Phone#: 61+- 531— City: PweNiitAra State: FL- Zip: 33) go Tenant/Lessee Name: Phone#: Email: NO Flood Zone: Address: CONTRACTOR: Company Name: Aa s- �� Phone#: Address: /� 1122-5 S City: sl L State: 1 Zip: Qualifier Name: ITQ'r -� ec) r12s16cc Z- State Certification or Registration #: G CL_(3 -S Certificate of Competency #: Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Phone#: Phone#: Value of Work for this Permit: $ 2 °►° Square/Linear Footage of Work: Type of Work: ❑Addition ❑Alteration Description of Work: New '. Repair/Replace l ;tc C tvLt, G /Ocd ❑Demolition Color thru tile. \-') *****+ x+ x*** ******************** * * * * * * **11*Feed J �x�x****�x�x+ + x**** a��x�xx�a� **** *** *** ** * ***+n***** Submittal Fee $ Permit Fee $ �J.T CCF $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ CO /CC $ Bond $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for RI.RCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which ccurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be appro a reinspection fee will be charged. Signature 0 - r Agent The foregoing instrument „ acknowledged before me this day of f t 20 jZ, by who is personally known to me or who has produced As identific on and who did take an oath. Contractor The foregoing instrument was acknowl day of 0 ,20 \1.,by a etR *S'o ALTAORACIA SPINAL * MY COMMISSION # DD 956783 14 Bonded Mrs Budget Notary Services ged bef9re me this �� �� , who is personally known to me or who has produced as identification who did take an oath. My Conunission Expires: Ai to) -0 /4 NOTARY PUBLIC: ign: t: s_4, o' ' T: `otary My Commission Exp • ublio Slats ®r FIeride Perez a44` My commission E61231121 r`0* Expires 08/21/2018 +********** *** *** * * *** * * * * * * * *s<s« * * * * **** fie***** **s<s:** ** *** * * * * * * ** *** * * * * ** * * * ** * * * * * * * * * * * * * * * * * * * * * * * **** APPROVED BY Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Zoning Clerk '`' R°� CERTIFICATE OF LIABILITY INSURANCE DATE ` ' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE :CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED:SY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certifleate holder Is an ADDITIONAL INSURED, the poilcy(tes) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on flds certificate does not confer rights to the cerBflcate holder In lieu of such endorsement(s). PRODUCER COMPREHENSIVE INSURANCE UNDERWRITERS 0 NE 92 STREET MIAMI SHORES, FL 33138 -2911 C ACT MARK STEVEN HOERBER P Egg (305) 759-0005 M, Nol: ice. {. x :reCAUOSIGMAIL.0 a ,< IBU )MFCRDNG CoVERADE +SAC# INSURER A: CANAL INDEMNITY INSURANCE CO INSURED ISAAC'S ROOFING & INSULATION CORP PO BOX 973135 MIAMI, FL. 33197 -3135 INSURER TRAVELLERS PROPERTY & CAS 10115/201210/1512013 INSURER C: EVANSTON INSURANCE CO IEACH OCCURRENC4 INSURERD: . ' °r . NrrEO ) INSURER El MED EXP Writ= ) INSURER F: • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURB1 NAMED ABOVE FOR THE POLICY .PERIOD INDICATED. NOTWITHSTANDING ANYREQuIREMENT, TERM OR CONDMON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT. TO WHICH°THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED' HEREIN IS SUBJECT TO .ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES. LiMrrs SHOWN SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. • L i TYPE OF INSURANCE I POLICY HUMBER , 1--,1 = - " . :i ','. A GENERAL X LA WRY LIABILITY COMMERCIAL GENERALU r Y' RENEWAL OF GL102237 BINDER 10115/201210/1512013 IEACH OCCURRENC4 s 1:,000,000 . ' °r . NrrEO ) s 50,000 MED EXP Writ= ) S 5 000 1 CLAIMS -MADE 1 X 1 OCCUR pensom aADVINJURY s 1,000_,000 5 3,000,000 GENERAL AGGREGATE PRODUCTS - COMPAP AGG 5. 3,000,000 GENI.AGGREGATE UMR APPLIES PER 1C I POLICY n .FECT n Loc $ 1 1,000,000 N $ UNIT B AUTOMOBILE X .- LIABILITY ANY AUTO NED HIRED AUTOS - SWUM ga y Eo N. BA 301M3714 -11 BODILY INJURY (Per pareon) S BODILY * (Per ) Y PE E s 1 C ` X MIME" LIAR I EXCESSLIAB X OCCUR CIAIMSMADE r r RENEWAL OF XOVA31291 BINDER CONFIRMATIONI 10/15/201210/151201 /1 OCCURRENCE 3 1,000,000 $ 1,000,000 AGGREGATE S DED I 1 RETENTIONS WORKERS COMPENSATION AND EMPLOYERS' LIAaH.RY IN ANv PROPRIETORNPART� Y� pg=igier EXCLUDED? If see, describe ender DESCRIPTION OF OPERATIONS below NIA' I TORYNU -I 1 VE$ E.L. EACH ACCIDENT $ E.LDI9EA9s DA EMPLOYEE $ E.L. DISEASE - POtCYLIMIT 1 DESCRIPTION OP OPERATIONS? LOCATIONS I VEHICLES (Attach ACORD 101, Additional Ranurke Sel edrda, If area apace le required) 1) Roofing & insulation contractor any & all locations, jobs and projects / FL State License # CCC 1325556 & 1327401. 2) ADMINISTRATIVE OPERATIONS ADDRESS: 17225 SOUTH DIXIE HWY#200, MIAMI, FL 33157 3) BLANKET ADDITIONAL INSURED IN FAVOR OF CERTIFICATE HOLDER WHEN REQUIRED. BY WRITTEN CONTRACT. - 4) BLANKET WAIVER OF SUBROGATION IN FAVOR OF CERTIFICATE HOLDER WHEN REQUIRED BY WRITTEN CONTRACT; CERTIFICATE HOLDER MIAMI SHORES VILLAGE 10050 NE 2ND AVE MIAMI SHORES, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE ;DELIVERED IN ACCORDANCE WITH THE POUCY PROVISIONS. AUTHORED REPRESENTATIVE MARK S'E1WET414 L LIC #A120671 ACORD 25 (2010105) ©1988 -2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD RoOFX�vG October 16, 2012 Miami Shores Village Building Department Joel Minski 9969 NW 4 Avenue Road Miami Shores, FL 33138 Re: Retrofit roof to wall connection To Whom It May Concern: Due to the design characteristics and size of the truss system of the above mentioned property, the cost of retrofitting the wall to roof connection is more than the allowable 15% by the Florida Building Code. (Scope of work) Remove 250 lineal ft. of tongue and groove wood sheathing to the entire perimeter of the house for access to the tie beam where the trusses rest. Once all of the straps are purchased and delivered to the site the straps will be mechanically attached to the tie beam with 13/4 " tap cons. Please note that one strap will be used per truss. After all straps are tied down to the perimeter and corners of the house, we will re -attach the sheathing back to its original state using ring shank nails. The cost of this work will be $6,237.60, which is more than 15% of the re- roofing contract therefore not required as per the Florida building code as defined in S.1609.2/101.2B. The retro fit process will cost $6,237.60 which is approximately 24% of the re- roofmg cost of $25,990.00. Should there be any questions or concern please feel free to contact our office. Sine el ain Gonzalez V. President oolLY Notary Pu is Stet- of Flori Daniel P : rez My Commi ion , 123821 Expires 08/ 1/201 P.O. BOX 973135, Miami, Florida 33197 -3135 TEL: (305) 234-5234 FAX: (305) 234 -5753 www.isaacsroafing,com Property Information: Folio 11- 3206 -017 -1230 Property Address 9969 NE 4 AVE RD Owner Name(s) JORGE GOMEZ &W MELISSA Mailing Address 543 MIN STREET APT 700 NEW ROCHELLE NY 10801 Primary Zone 1200 SGL FAMILY - 2501 -2800 SQ Use Code 0001 RESIDENTIAL - SINGLE FAMILY Beds /Baths /Half 4/3/0 Floors 2 Living Units 1 Adj. Sq. Footage 3,571 Lot Size 17,026.10 SQ FT Year Built 1951 Legal Description MIAMI SHORES SEC 4 AMD PB 15-14 LOTS 1 & 2 BLK 96 LOT SIZE 130.970 X 130 OR 17157 -4662 04961 COC 26228- 0176/0178 12 2007 1 OR 26228 -0176 1207 00 Assessment Information: Current Previous Year 2012 2011 Land Value $243,877 $212,067 Building Value $309,379 $309,623 Market Value $553,256 $521,690 Assessed Value $537,340 $521,690 Exemption information: Current Previous Year 2012 2011 Homestead $25,000 $25,000 2nd Homestead $25,000 $25,000 Senior $0 $0 Veteran Disability $0 Civilian Disability $0 $0 WIdow(er) $0 $0 Disclaimer: MIAMI -DADE COUNTY OFFICE OF THE PROPERTY APPRAISER PROPERTY SEARCH SUMMARY REPORT Honorable Pedro J. Garcia Property Appraiser Aerial Photography 2012 Taxable Value ir►fortnadon: Current Previous Year 2012 2011 Exemption/Taxable Exemption/Taxable County $50,000 / $487,340 $50,000 / $471,690 School Board $25,000 / $512,340 $25,000 / $496,690 City $50,000 / $487,340 $50,000 / $471,690 Regional $50,000 / $487,340 $50,000 / $471,690 Sale information: Date Amount Recording Qualification Code Book -Page 5/2007 $0 25681-4482 Sales which are disqualified as a result of examination of the deed 12/2007 $750,000 26228 -0176 Sales which are qualified 4/1996 $275,000 17157 -4662 Sales which are qualified 11/1993 $265,000 16148 -4551 Sales which are qualified 10/1977 $120,000 09824 -0445 Sales which are qualified The Office of the Property Appraiser and Miami -Dade County are continually editing and updating the tax roll and GIS data to reflect the latest property information and GIS positional accuracy. No warranties, expressed or implied, are provided for data and the positional or thematic accuracy of the data herein, Its use, or its interpretation. Although this website is periodically updated, this information may not reflect the data currently on file at Miami -Dade County's systems of record. The Property Appraiser and Miami -Dade County assumes no liability either for any errors, omissions, or Inaccuracies in the information provided regardless of the cause of such or for any decision made, action taken, or action not taken by the user In reliance upon any Information provided herein. See Miami -Dade County full disclaimer and User Agreement at http: / /www.miamidade.gov /Info /disclaimer.asp. Property Information inquiries, comments, and suggestions email: pawebmail@miamidade.gov GIS inquiries, comments. and suggestions email: gls @miamidade.gov Generated on: Tuesday, October 16, 2012 '9.wmer's Notification Form 07 • "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES.- REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofmg contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. . Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renaffing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofmg contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofmg nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. . Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Mir 110' 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. . Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida- licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's /Agent's Signature: Contractor's Signature: Property Address: ■4. Date: Permit Number: Section A "Delivering Excellence Every Day" Master Permit No: C. \ Miami -Dade County Building Department Electronic application High Velocity Hurricane Zone Roofing Permit Application Form Section A (General Information) Process No: Contractor's Name: Isaacs Roofing Job Address: 9969 NE 4th Ave.Rd ❑ Low Slope ❑ Asphaltic Shingles ❑ Sprayed Polyurethane Foam ❑ New o e Roof Category ❑ Mechanically Fastened Tile 0 Mortar /Adhesive Set Tile ❑ Metal Panel /Shingles ❑ Wood Shingles /Shakes ❑ Other: Roof Type Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance ere as r} Stacks located on the roof? ❑ Yes 0 No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slo e . of-a'rea Sketc dimen Steep Sloped area (ft.2) 4000 Section B (Roof Plan) Total (ft.2) 4000 rate - evels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include on and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Comer Size (a' x a'): 49' 53' APPROVED ZONING DEPT BLDG DEPT • It . • °T DATE 7 vr S 1 BJECTTO COMPLIANCE WITH ALL FEDERAL S ATE AND COI INTY RULES AND REGULATIONS 39' ZNN 37' j - Tile Roof System "Delivering Excellence Every Day" Roof System Manufacturer: Miami -Dade County Building & Neighborhood Compliance Department HVHZ Electronic Roof Permit Form Section D Tile Roof System Entergra Notice of Acceptance Number (NOA): 10-1202.01 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1: 45.1 P 2: P 3: Maximum Design Wind Pressures, (From the NOA Specific system): 66.5 psf Fill in the specific roof assembly components. K a component Is not required, insert not applicable (n/a) in the text box. Roof Slope: "/12" Roof Mean Height 20 ft. Method of Tile Attachment: Adhesive, Large Paddy Polyfoam Polypro -- Alternate Method of Tile Attachment per NOA: Drip Edge Size & Gauge: Drip Edge Material Type: Drip Edge Fastener Type: 1 -3 face 26 ga. - -_ -- Galvinized Metal -- 11/14" ring shank Hook Strip /Cleat gauge or weight: -- Select Hook Strip — Deck Type: a Optional Insulation: 1n/a Optional Nailable Substrate: n/a Optional Nailable Substrate Attachment in /a Basesheet Type: 30# Fastener Type for Basesheet Attachment: ng shank and nails. Tile Underlayment (Cap Sheet) Type: 90# Tile Underlayment Attachment Method: hot mopped Tile Profile: [Flat' Section E MIAMI -DADE "Delivering Excellence Every Day" For Uplift ba each area of the of, then the tile attachment method is acceptable. Miami -Dade County Building & Neighborhood Compliance Department HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: P 2: P 3: 100.7 x� x� x� .289 .289 29.10 - Mg: - Mg: - Mg: 7.79 7.79 = Mr1: = Mr2: = Mr3: 40.4 40.4 40.4 Method 3 "Uplift Based Tile Calculations Per RAS 127" NOA Mf NOA Mf NOA Mf tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for P1: P2: P3: x w: x X w: - W: - W: - W: 'cY.r- ir"1rai,..vre1}•11•11.1 .1 a.a- x cos 01:1 = Fr1: x cos 0: = Fr2: x cos 0: = Fr3: on to complete tile calculations Description Design Pressure Symbol Where to Find NOA F' NOA F' NOA F' P1 or P2 or P3 Table 1 RAS 127, engineer based on A by an engineer analysis prepared, signed and sealed by a professional E 7. Mean Roof Height Roof Slope Aerodynamic Multiplier Restoring Moment due to Gravity Job Site Attachment Resistance Required Moment Resistance Job Site ct Approval (NOA) royal (NOA) Product A Product Approv Calculated Minimum Attachment Resistance Required Uplift Resistance Average Tile Weight Tile Dimensions F' Product Approval (NOA) Fr Calculated W Product Approval (NOA) I = length w = width Product Approval (NOA) MIAMI =CAGE COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Entegra Roof Tile, Inc. 1289 NE 9°' Ave Okeechobee, FL. 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA No. 10- 0804.15 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. ML DADE COUNnt APPROVED NOA No.: 10- 1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This renews a roofing system using Entegra "Plantation" concrete roof tile, as manufactured for Entegra Roof Tile, Inc. in Okeechobee, FL as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description Plantation Tile Length: 1614" Fiat concrete roof tile for direct deck or Width: 13" TAS 112 batten nail -on. Trim Pieces Length: varies Accessory trim, concrete roof pieces for Width: varies TAS 112 use at hips, rakes ridges and valley Thickness: varies terminations 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION: 4.1 Entegra Roof Tile, Inc.'s Plantation Flat Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,119, & 120 4.2 Data For Attachment Calculations . APPROVED NOA No.: 10- 1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 2 of 5 Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Plantation Tile 11.6 1.375 1.08 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Table 2: Aerodynamic Multipliers - X (ft3) 2 ": 12" Tile 4": X, (ft3) ": X (ft3) Profile 38.1 Batten A. . l!cation Direct Deck A ' , lication Plantation Tile 6 12" 0.267 2 -10d Smooth or Screw Shank Nails 0.289 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile 2 ": 12" 3 ": 12" 4": 6 ": 12" ": Greater than Profile 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 6 12" 7 ": 12" 2 -10d Smooth or Screw Shank Nails Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 24.3 24.3 Deck 1 -10d Smooth or Screw Shank Nail (Eave Clip) Deck 19.0 Deck 2 -1Od Smooth or Screw Shank Nails (Field Clip) Deck 35.5 Deck 2 -1Od Smooth or Screw Shank Nails (Eave Clip) Deck Plantation Tile 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) For Nail -On Systems Tile Profile .Fastener Type Direct Deck (Min 15132" plywood) Direct Deck (Min. 19132" plywood) Battens Plantation Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -1Od Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -1Od Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails.' 50.3 65.5 48.3 1 Installation with a 4" tile headlap and fasteners are located a minimum of 2 /a° from the head of tile. MIAM4DADE COUNTY APPROVED NOA No.: 10- 1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 3 of 5 Table 5: Attachment Resistance Expressed as a Moment Mr (ft-Ibf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 31.33 2 See manufactures com . onent a. +roval for installation re. uirements. 3 Flexible Products Company TileBond Average weights per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile PolyProTM 118.04 PolyProTM 40.4b 4 Large paddy placement of 45 grams of PolyPro TM. 5 Medium paddy placement of 24 grams of PolyProTM. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance See specific mortar manufacturer's Notice of Acceptance. 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved ". 5.2 Entegra Roof Tile, Inc.'s Plantation Roof Tile bears the following markings: USA "E" USA, "E ", Entegra "E ", where the E is a stylized logo. 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. 7. MANUFACTURING LOCATIONS 7.1 Okeechobee, FL MANMADE COUNTY APPROVED NOA No.: 10- 1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 4 of 5 PROFILE DRAWING PLANTATION FLAT CONCRETE TILE END OF THIS ACCEPTANCE MIAMFDADE COUNTY APPROVED NOA No.: 10- 1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 5 of 5