Loading...
SGN-12-1428Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 176486 Permit Number: SGN -7 -12 -1428 Scheduled Inspection Date: October 22, 2012 Inspector: Bruhn, Norman Owner: , Job Address: 9820 NE 2 Avenue Miami Shores, FL 33138- Project <NONE> Contractor: KLEAN POWER ELECTRIC INC Permit Type: Sign Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1132060132240 Building Department Comments ILLUMINATED REVERSE CHANNEL LETTER RELOCATION FROM EXISTING LOCATION 9806 NE 2 AVE TO NEW LOCATION 9802 NE 2 AVE. Inspector Comments PassedG! a ,c;t ,L- Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. October 19, 2012 For Inspections please call: (305)762 -4949 Page 14 of 45 Miami Shores Village Building Department ?0050 N.E.2nd Avenue, Miami Shores, Florida 33138 ./ Tel: (305) 795.2204 Fax: (305) 756.8972 1 L,,U X10 INSPECTION'S PHONE NUMBER: (305) 762.4949 UILDING PERMIT APPLICATION Perot Type: BUILDING JOB ADDRESS: �� Ai t e4 AVQ 98OR RECEIVED JUL 272012 FBC 20 l® Permit No. Master Permit No. S6*1 I Z ' I Lae ROOFING City: Mi__a��mi.�$�,,,�,omc County: Miami Dade Zip; 31 R. Folio/Parcel #: 1 , �0 `' 4 # Is the Building liistoricalty Designated: Yes Flood Zone: OWNER: Name (Fee Simple Titleholder): k4 vs., lrll l t /ti S fx. 6,103Phone#: -3 O5 - 6 e/ -863 S Address: Zl Q a) s 4 rv, 3c2 City: ) 1ic A .,4-1 State: Ft", Zip: 331 u 1 Tenant/L.cssce Name: 14_ r/ %i 4V,Crie ✓ Prone #: 3 ea 5 - 351 -95SO Email: CONTRACTOR: Company Name: Elect n g r ee?cc tic-- Address: 660 1 5'N.+ g o e 5'4 AL, City: A‘P _, G�yvc state: `F' - zip: l �31'i 3 Qualifier Name: 6,1\1 t ncy� � nw Q1 r1S -- -_ Phone#: 303 : L 1 -Is/ se/ 305 669 -SI sy State Certification or Registration #: - Contact Phone#: 305 •66 - 'I y Email Add DESIGNER: Architect/Engineer;�f _ Certificate of Competency #: r s: e :rte. R" Y.Cry thiVir u one: 305 ° 74 2 -75y9 Value of Work for this Permit: $ 1. 00 O Square/Linear Footage of Work: )aNew 13Repait/Replae re Type of Work: LIAddnion Description of Work: XSVery {0 UAtteration UIDemolitietn Color thru tile: *4r Submittal Fee Scanning Fee $ Notary $ Double Fee $ e314xagaas44sr r$ r***rte tr r1 Permit Pee $ Radon Fee $ TraininglEducation Fee $ Structured Review $ Fees** iir4 R *+aura 5ei*010*x **** ******0GI*** CCF $ C O/CC $ DBPR $ Bond Technology Fee $ TOTAL FEE NOW DIPI;' 1 l '(Q f3 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Nante t if applicable) Mortgage Lender's Address City: State Application is hereby made to obtain a permit to du the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a perrnit and that all work will he performed to nice thr xtundards of an laws trembling construction in this jurisdiction. I undersamd that a separate permit must be secured for ELECTRICAL WORK, PLUMBING. SIGNS. WELLS, POOLS, FURNACES. BOILERS. HEATERS. TANKS and AIR CONDMONERS, OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicanv As o condition to the issuance of a buthimg perm: with an estimated value exceeding $2500. the applicant must promise in Rood ,faith that a copy of the notice of co, mencement! and construction hen /air brochure will be delivered to the person whore property is subject to attachment. Also, o certified copy of du recorded notice of commencement roust be posted at the job she Jot the first inspection which occurs seven (7) days after the building permit is issued. lea the absence of such posted notice, the inspection will not be approved and a reinspection et, will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of 20 r7r by who is prsona e or who has produced_____ As identification and who did take an oath. NOTARY PUBLIC: b), The foregoing Contractor =nil was acknowledged before me this (49 6 6,1tAli Sign: Print: Di\ 0. pit My Commission Expires: ORIT MIMOUN Commission # DD 946625 6.,11111, My Commission Expires : . ,ZeiF 0-00 December 14, 2013 ***4*V 7/J- Plans Examiner „ . Stitirtural Review rlIcvi5ed3/12.,2012)xitnt,.ed Olid IWO? xRzyili*Jefirii);200exkvv**d 3I151, who has produced OS id non and who did take an oath. NOTARY PUB Sign: Print: My Commis 0.• :=41111":' COMMON' 42558°- • • Expas:septembed3A14 awdedvaudgetwANY vats Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Date: Date: 7/27 /,2 Permit #: �2 _ /442 ef Planning & Zoning Critique Sheet Ai, Review Completed by: David A. Dacquisto THE PLAYGROUND REVERSE CHANNEL LETTERS Facade: 60 W J41 x,,N■ South-West Elevation Location: 9802 NE 2nd Ave, Miami Shores. FL 33138 17 H Sign Dimentios: 15'- 06" x 4'-04" = 67 Sq. Ft 15'-- 06" PtaG d u 4'- 04 iK)Nt,311,1 RF,X17■ ' F ,AFT-At To:e, PAT ^`, , •-j t HeUE. Mt- A f3,4..A.,i.S 14.T NAt 17, WV,F, FAT aL hP- SL Nki 4 r:F.R k.T74 0 t TT .P ' AMP 01; 111tr- ; Section Thru Reverse Channel Letter TA1 "R &NCI' (4 ). VANtif 'RANFif ORMF AVFR Pt12 6PY) 2 AMP DISCONNECT ANC.E F ■-'1,7Ar.KFT it. ‘r;a) 12/ ANGLE 2X1Xi" ATTACHED TO WALL WITH a -" X2 -14" TAPCONS AS REQUIRED ON CALCULATIONS N.O.A. 07- 0315.03 I' ALUMINUM THRU BOLT ANGLE 1- 114 "X1 - 114 "X118" 6063 T5 ALLOY PLAYGROUND THEATER SIGN EXISTING CMU WALL T 9802 N.E. 2ND AVE. w .E.D. POWER SUPPLY GROUT FILLED CELLS (TYPICAL) TYPICAL CROSS SECTION (N.T.S.) NOTES: 1. ALL WORK TO BE DONE WITH THE CURRENT MINIMUM REQUIREMENTS OF THE FLORIDA BUILDING CODE 2010 EDITION. 2. WIND CALCULATIONS PER ASCE 7 -10 AND FBC 2010 POSITIVE PRESSURE: NEGATIVE PRESSURE: 46.08 PSF 49.96 PSF 3. ALL ELECTRICAL WORK, INCLUSIVE OF WIRING AND INSTALLATION SHALL BE DONE WITH THE PROVISIONS OF THE CURRENT FBC 2010 AND NEC CODES. 4, PRIMARY ELECTRICAL SERVICE BY OTHERS 5. ALL BREAKERS AND TIMING DEVICES (IF ANY), SHALL BE IDENTIFIED AT TIME OF INSTALLATION. SERVICE DISCONNECT AS PER N.E.G. 600-2 6. UNLESS OTHERWISE NOTED, ALL ALUMINUM MATERIALS TO BE 6063 -T5 ALLOY. 7. UNLESS OTHERWISE NOTED OF ANY), ALL STEEL TO BE ASTM A-36 8. WHEN ALUMINUM FRAMES ARE USED, ALL BOLTS AND ANCHORS TO BE EITHER STAINLESS STEEL (304) AND/OR GALVANIZED. NO EXCEPTIONS TAKEN. 9. ALL WELDING (IF ANY), TO BE 00149 WITH FULL COMPUANCE WITH THE CURRENT A.W.S. STANDARDS. ELECTRODE SIZES AS NOTED ON DRAWINGS . 10. USE E-5356 ELECTRODES FOR ALUMINUM FRAMES AND E7018 FOR STEEL FRAMES. ALL WELDING TO BE DONE UNDER THE DIRECT SUPERVISION OF A A.W.S. CERTIFIED WELDER. 11. FOR ADDITIONAL INFORMATION ON SIGN REQUIREMENTS, REFER TO FBC 2010- 423.10.6 Facade: 60' W FLORIDA RIM VERN 17 11 TABIO ENGINEERING CORPORATION CIVIL - STRUCTURAL ENGINEERING CA 09550 140 BUTTONWOOD DRIVE, KEY BISCAYNE, FLORIDA 33149 PHONE: 305 - 772 -7599 FAX: 305- 361 -9376 e -mail: tabioeng @aol.com OESCRIFITION PLAYGROUND THEATER 9802 N.E. 2ND AVENUE, MIAMI SHORES, FLORIDA33138 WALL SIGN - REVERSE CHANNEL LETTERS ;cud: AS NOTED Dams 8Y M.S. DATE 07/05/2012 CHECKED 8Y M.S. mesa mutest o' S -1 TABIO ENGINEERING CORPORATION CA09550 140 BUTTONWOOD DRIVE, KEY BISCAYNE, FLORIDA 33149 PHONE: 305 - 772 -7599, FAX: 305 - 361 -9176 email: msalazar @tabioengineering.net PLAYGROUND THEATER 9802 N.E. 2ND AVE MIAMI SHORES, FLORIDA 33138 REVERSE CHANNEL LETTER SIGN DESIGN BY : MAURICIO SALAZAR, P.E. DATE : JULY 05, 2012 FLORIDA LICENSE #55757 Page 1 of 7 MECAWind Version 2.1.0.7 per ASCE 7 -10 Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.com Date : 7/5/2012 Project No. . Company Name : TABIO ENGINEERING CORP. Designed By . Address Description : THEATER PLAYGROUND City Customer Name State Proj Location MIAMI SHORES, FLORIDA File Location: Z: \Lyla's Doc \EYE CATCHING SOLUTIONS \PLAYGROUND THEATER \WIND CALCS.wnd Directional Procedure All pressures shown are Basic Wind Speed(V) _ Structural Category = Natural Frequency = Importance Factor = Damping Ratio (beta) _ Alpha = At = Am = Cc = Epsilon Slope of Roof Ht: Mean Roof Ht RHt: Ridge Ht OH: Roof Overhang at Eave= Bldg Length Along Ridge = Simplified Diaphragrm Building (Ch 27 Part 2) based upon ASD Design, with a Load Factor of .6 175.00 mph II N/A 1.00 0.01 9.50 0.11 0.15 0.20 0.20 0 : 12 29.00 ft 29.00 ft 3.00 ft 125.00 ft Exposure Category Flexible Structure = Kd Directional Factor = Zg Bt Bm 1 Zmin Slope of Roof(Theta) Type of Roof Eht: Eave Height Roof Area C No 1.00 = 900.00 ft = 1.00 = 0.65 = 500.00 ft = 15.00 ft • .00 Deg = Monoslope = 29.00 ft = 25750 ft ^2 Bldg Width Across Ridge= Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq. >1 Hz) use 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6 *Ht lzm: Cc *(33 /Zm) ^0.167 Lzm: 1 *(Zm /33) ^Epsilon Q: (1/(1 +0.63 *((B +Ht) /Lzm) ^0.63)) ^0.5 Gust2: 0. 925*(( 1+ 1.7 *lzm *3.4 *Q) /(1 +1.7 *3.4 *lzm)) Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 203.00 ft = 0.85 = 17.40 ft = 0.22 = 439.92 ft = 0.84 = 0.84 0.84 Table 26.11 -1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/ -0.18 Topographic Adjustment 0.33 *z Kzt (0.33 *z): Topographic factor at elevation 0.33 *z Vtopo: Adjust V per Para 27.5.2: V * [Kzt(0.33 *z)] ^0.5 Net Wind Pressures on Walls (Table 27.6 -1) Wall Pressures do not include effect of internal pressure • 9.57 • 1.00 = 175.00 mph MWFRS -Wall Pressures for Wind Normal to 203 ft wall L/B ph: Net Pressure at top of wall (windward + leeward) p0: Net Pressure at bottom of wall (windward + leeward) ps: pl: pwh: pw0: Side wall pressure acting uniformly outward = .54 * ph = Leeward wall pressure acting uniformly outward = .38 * ph= Windward wall pressure acting uniformly outward = ph -pl = Windward wall pressure acting uniformly outward = p0 -pl = 0.62 41.72 psf 40.21 psf 22.53 psf 15.85 psf 25.86 psf 24.36 psf Page 2 of 7 MWFRS -Wall Pressures for Wind Normal to 125 ft wall L/B = 1.62 ph: Net Pressure at top of wall (windward + leeward) = 38.20 psf p0: Net Pressure at bottom of wall (windward + leeward) = 36.95 psf ps: Side wall pressure acting uniformly outward = .6 * ph = 23.01 psf pl: Leeward wall pressure acting uniformly outward = .31 * ph= 11.89 psf pwh: Windward wall pressure acting uniformly outward = ph -pl = 26.31 psf pw0: Windward wall pressure acting uniformly outward = p0 -pl = 25.06 psf See Fig 27.6 -2 for Parapet wind Roof Pressures pressures See Table 27.6 -2 Mean roof ht. Wall Pressures See Table 27.6 -1 Elevation Wind Plan Net Wind Pressures on Roof (Table 27.6 -2): Exposure Adjustment Factor = 1.000 Zone Load Casel Load Case2 psf psf 1 .00 .00 2 .00 .00 3 -41.39 .00 4 -36.88 .00 5 -30.27 .00 Note: A value of '0' indicates that the zone /load case is not applicable. Page 3 of 7 hp PP 1 Flat Roof Parapet Wind Loads (Figure 27.6-2): ph walt pres from Table 27.6-1 at height h Load Case 1: Povh1: Overhang Povh3: Overhang Load Case 2: Povh1: Overhang Povh3: Overhang h Additional toad on MINFRS from all parapets and .parapet striates mean roof ht 2.25 times the pressure determined from Table 27.64 for a height measured to the top of the parapet 00 Roof Overhang Loads (Figure 27.6-3): pressure for zone 1 pressure for zone 3 pressure for zone 1 pressure for zone 3 .00 psf -31.04 psf .00 psf .00 psf Page 4 of 7 Roo re from table a or "clod zte� Parapet: hp: Height to Top of Parapet = 32 ft php: Wall Pressure for L/B = 1 at hp (Fig 27.6 -1) = 42.27 psf pp: Parapet total pressure (Leeward + windward) - 2.25 *php = 95.11 psf Page 5 of 7 MECAWind Version 2.1.0.7 ASCE 7 -10 Developed by MECA Enterprises, Inc. Copyright 2012 wwww.mecaenterprises.com Date : 7/5/2012 Project No. Company Name : TABIO ENGINEERING CORP. Designed By . Address Description : THEATER PLAYGROUND City Customer Name : State Proj Location : MIAMI SHORES, FLORIDA File Location: Z: \Lyla's Doc \EYE CATCHING SOLUTIONS \PLAYGROUND THEATER \WIND CALCS.wnd Flat Roof Interior Zones -zone -Zara End Zones - 2 /Web -Zon Corner Zones -Zone 3 Wind Pressure on Components and Cladding (Ch 30 Part 2) All pressures shown are based upon ASD Design, with a Load Factor of .6 Description Width Span Area Zone Max P Min P ft ft ft ^2 psf psf Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 2H Zone 3H 1.00 1.00 10.0 1 18.72 - 46.08. 1.00 1.00 10.0 2 18.72 -77.30 1.00 1.00 10.0 3 18.72 - 116.33 1.00 1.00 10.0 4 46.08 -49.96 1.00 1.00 10.0 5 46.08 -61.66 1.00 1.00 10.0 2H .00 -66.37 1.00 1.00 10.0 3H .00 - 109.30 Notes: 1) If Zone = "2H" or "3H" then MaxP will be zero per Figure 6 -3. 2) Max P & Min P = pnet30(from Fig.30.5 -1) * Lambda * Importance Factor * Kzt. 3) If Area <10 then Area =10 or Area >100 then Area =100 for Zones 1, 2, 3, 2H & 3H. 4) If Area<10 then Area =10 or Area >500 then Area =500 for Zones 4 & 5. Parapets Components & Cladding (Ch 30 Part 4, Para 30.7.1.2) Pressures taken from Table 30.7 -2 at top of Parapet and multiplied by Exposure Adjustment Factor (EAF = 1.390), Topographic Factor (Kzt = 1.00) and Reduction Factor (RF = 1.0). The effective area for the parapet is 10 sq ft [0.929 sq m] to be Page 6 of 7 • • o conservative, which makes the Reduction Factor 1. Windward parapet Lc d Case A —11 4 pg. —! Wit► —4 ► —i pl —► J1 -4 -4 Leeward parapa1 Load Case B Top of paapvt Load Case A - Apply Positive Wall Pressure to Front and negative roof pressure to back. p1: Positive Wall Pressure on Front of Parapet (Zone 4) pl: Positive Wall Pressure on Front of Parapet (Zone 5) = 61.15 psf 61.15 psf p2: Negative Roof Pressure on Back of Parapet (Zone 2) _ - 140.37 psf p2: Negative Roof Pressure on Back of Parapet (Zone 3) = - 191.33 psf Load Case B - Apply Positive Wall Pressure to Back and Negative Wall Pressure to the front. p3: Positive Wall Pressure on Back of Parapet (Zone 4) = 61.15 psf p3: Positive Wall Pressure on Back of Parapet (Zone 5) = 61.15 psf p4: Negative Wall Pressure on Back of Parapet (Zone 4) = -61.15 psf p4: Negative Wall Pressure on Back of Parapet (Zone 5) _ - 112.06 psf Page 7 of 7