RF-12-1072Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 174768 Permit Number: RF -6 -12 -1072 Scheduled Inspection Date: September 25, 2012 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Miami Shores, FL 33138- Project: BARRY UNIVERSITY Contractor: Z ROOFING INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1121360010160 Building Department Comments NEW MODIFIED BITUM COAT ON STORAGE AND TICKE BOOTH BUILDING Inspector Comments Pass ed , Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. September 24, 2012 For Inspections please call: (305)762 -4949 Page 9 of 30 08/17/2012 13:20 13050000000 tAD1AJGTE PAGE 01 AoCC7=R° CERTIFICA OF LIABILITY INSURANCE ZROOF -1 OP ID; GC DATE (MMIDPA TYY) 05/30/12 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsemcnt(ss_ PRODUCER Workers Compensation Group P 0 Box 410 Workers Raton, FL INSURED Z Roofing & Waterproofing Inc 2525 W, 3rd Ct. Hialeah, FL 33010 561 -392 -3300 NAMEACT Greg Carignan 561- 361 -1132 N . E„t):561- 392 -3300 - j )561 - 361-132 AU RESS : COrtS orkerscom yg rou • cOm INSURER(S) AFFORDING COVERAGE INSURER A ; Brldgefieid Employers Ins INSURER B : INSURER C: INSURER O : NAIL S 10701 INSURER E I RERP: COVERAGES • • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS 11 N . IC TYPE OF INSURANCE AD Mtn/ , - ° POLICY NUMBER POLICY Dt'P , . D POLICY EXP M CD LIMITS GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ VATAAL i V ' oo f ED �EMISSPIRA occu.Irer/ce)_ MW EXP (Any one person) $ __ CLAIMS•MADE OCCUR Ell $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PIE LOC PRODUCTS - COMP/OP AGO $ $ AUTOMOBILE _�. LIAsILrry COMBINED SINGLE LIMIT (ES =Went) 2: $ ANY AUTO AUTOS HIRED AUTOS — SCHEDULED NON�OWNEO AUTOS BODILY INJURY (Per pornon) BODILY BODILY INJURY (Per Seddent) $ PROPERTY DAMAGE (Par ;faddist)_ $ $ A UMBRELLA LIAB EXCESS [JAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE S DED R 3Y; NTION;. $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / 830 -48391 aa/13/12 06/13113 ITO I EWO STATU. 0TR H. 4. N ANY PROPRIETOR/PARTNER/EXECUTNE OFFICERtMEMB�IER EXCLUDED? N /A EL CACH ACCIDENT $ 100,000 (Mandatory In IdH) If GRIPT ON OF OPERATIONS be ow E.L DISEASE • ISA EMPLOYEE _ $ 100,000 EL DISEASE - POLICY UMIT $ 500 000 DESCRIPTION OP OPERATIONS / LOCATIONS I VEHICLES (Attach ACORD 901, AddIdonnl Romnrka Sohodulo, If more specs ie required) "O ile,,'ATI! 1_,w, wim w MIAMIS3 Village of Miami Shores 10050 NE 2nd Ave. Miami Shores, FL 33138 CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS, AUTHORIZED REPRESENTATIVE ©1958 -2010 ACORD CORPORATION. All rights reserved. ACORD 25 (2010/05) The ACORD name and logo are registered marks of ACORD 08/1712012 13:20 13050000000 E`_AD1AJGTE PAGE 02 ZROOF -1 '4`�.°- R °-R° CERTIFICATE OF LIABILITY INSURANCE OP ID: CM DATE (MMIDPIYWY) 01/16/12 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the pollcy(Ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Insurance Services of Delray 409 SE 7th St Fort Lauderdale, FL 33301 Douglas A. Levy INSURED.. do`oting & Waterproofing Inc Lissette Pacheco 2525 W 3rd Ct Hialeah, FL 33010 561 -637 -3399 CONTACT NAME: PHONE E -MAIL ADDRESS) L_(FA/C, No): INSURER(S) AFFORDING COVERAGE INSURER A : Canal Indemnity Co. INSURER t7 : NAIC COVERAGES ICATE NUMBER: INSURER C INSURER D : INSURER E: INSUR F • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. Itntri L TYPE OP INSURANCE ADDL. INCR 9UMR WVD POLICY NUMBER (MMIDDlYY 1 fMMIIDDIYt I'Y1 ' LIMITS A GENERAI. LIABILITY GL102529 01111/12 01/11/13 EACH OCCURRENCE $ 1,000.000 X COMMERCIAL GENERAL LIABILITY 7 CIAMS -MADE [J OCCUR UAMAGETORENTED PREM18E8 (t_e o&�u¢erlcs) S 50,000 MED EXP (Any one pawn) $ 5.000 PERSONAL & ACV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEM. AGGREGATE LIMIT APPLIES PER: PRODUCTS • COMP/OP AGG $ 2,000,000 _!�__) 1?Oum, P - I LOC $ AUTOMOBILE LIABILITY _ COMBINED SINGLE LIMIT (Ea accident) $ -, — ANY AUTO AALLU BODILY INJURY (Per Doran) $ OvdNED HIRED .. AUTOSU NON -OWNED AUTOS BODILY INJURY (For eccklent) $ 1`+(�OPERTY DAMAGE (Pot OOeItleM $ $ „� UMBRELLA LIAB EXCESS LIAB • — OCCUR CL dM$.MADE EACH OCCURRENCE $ AGGREGATE $ DEC RETENT ON. $ WORItERSCOMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIE�TTOR/PARTNERe Y f N XECUTIVE OF ICENMEMBER EXCLUDED' U (Mandatory yyepcc defibe under DESCRIPTION OF OFEBATIONS bedew N I A WOSTATU• OTH- TOELLIM!T$ S5.— $ GL EACH ACCIDENT E.L. DISEASE • EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ _DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If mete space Is required) Roofing Contractor J HOLDER CANCELLA'T'ION Miami Shores Village 10050 NE 2nd Avenue Miami Shores, FL 33138 ACORD 25 (2010/05) MIAMISH SHOULD ANY OF THE ABOVE DESCRIBED POL IcIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE cgl 19884010 ACORD CORPORATION. All rights reserved. The ACORD name and logo ere registered marks of ACORD Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: (.1300 A E . Mc- City: Miami Shores County: Folio/Parcel #: i f -/ 3 — cyrb ° (J 0 Sv �. C; :IVED JUN 12 012 FBC 20() Permit No. PC" `j'' b-1, 2 Master Permit No. CC / - — ROOFING 5,1-5s4A Lc fSof� ?iBA-4- 6-70J 7-10174(&: Zip: Miami Dade Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): & WRY /)i it us t r y Phone #: 30C- 71'? - 3R95-- Address: / / 306 N & 'UWE- City: ty: (4 (# t 1 '51'f State: F-4 Zip: 331 6/ Tenant/Lessee Name: Phone #: Email: rim @ MAIL- , ,8h2425f m CONTRACTOR: Company Name: 2. — 4..1-t\, A (_ Phone #: I0 C° 6 % 3° N-6-3 Address: a. S.. 5- 1/3 3 r� anAier / City: / t11-4- State: Zip: 3 3 01 Qualifier Name: #tL °SI't Phone #: State Certification or Registration #: C_C C�' / 3a- 96Z)3 Certificate of Competency #: Contact Phone #: Email Address: DESIGNER: Architect/Engineer: Nikr3 WG(e '5‘113 A't- 01%SKI 11'$SOCUPTOS Phone #: q'#- q 41 - B$a% Value of Work for this Permit: $ 51 0 ® `® Square/Linear Footage of Work: C S-F Type of Work: °Addition °Alteration ew ORepair/Replace °Demolition Description of Work: A. tv%) dt-�f t'1 � 14-Q11-0,67 Co 40-1 540/-1-,3e- '7; t boo-ft. -J7 0)7, Color thru tile: %P c) Submittal Fee $ �0/ Permit Fee $ ® CCF $ CO /CC $ ,,,m.. Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City --- State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be .osted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence . ch mice, the inspection will not be approv d a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of SA , 20 , by 13 LK GbVIAR 2/ ' egoing instrument was acknowledged before me this '41/4, who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expir APPROVED BY Structural Review to me or who has produced as identification and who did take an oath. NOTARY PUB Sign: Print AbirAr- ,��II2:10i My Commission Expi . .•. Jonathan Cueste }�• ^`e��SION#EE041198 %; I��cm EXPIRES: NOV. 09, 2014 C: (Revised 5/2/2012)(Revised 3 /12/2012XRevised 07 /10 /07XRevised 06 /10/2009)(Revised 3/15/09) Zoning Clerk Permit No: 12 -1072 Job Name: August 6, 2012 Miami Shores Viiiage Building Department Building Critique Sheet 1) Provide a high velocity roofing application. STOPPED REVIEW 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re-submittal drawings. Norman Bruhn CBO 305 - 762 -4859 AU I v ,-- It Pi BY: -------- SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. . Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. . - Rena!ling wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. >BE Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. -NW Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. - Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. ,►:- Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. ) 3E_ Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. 8 /8 /z Ow er /Agent's Signature Date Contractor Signature " Date Revised on 7/9/2009 LD s. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 4402.14 HIGH- VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A B.0 1,2,3,4,5,6.7 Prescriptive BUR -RAS 150 A,B,C 4.6,6.7 Asphaltic Shingles A,B,D 1,2.4,6.6.7 4.6.6.7 Concrete or Clay Tile A,BD,E Metal Roofs A.B,D 1,2,3,4,5,6,7 Wood Shinclesand Shakes A E3,p 1.,2,4,5,6,7 Other As Applicable 1,2.3,4.5.6.7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Facie 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 , 4. Other Component of Product Approval 5. MuniclpiI Permit A_ppiication 6. •wn-rsN• Wee ion or.R•ofin. on i•- rat' •ns '_:r•ofin• •n 7. Any Required Roof Testing /Calculation Documentation FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Editio High - Velocity Hurricane Zone Uniform Permit Ap SeCtion A ( enPral lnfnrma Master Permit No. _ Proce Contractor' Job aE ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Metal Panel /Shingles ❑ Wood ShingleslShakes Miami Shores Village APPROVED I7ittIMIG DEPT `g69 PT ECT TO COMPLIANCE WITH ALL FEDERAL ;, QTTATE AND CO l INN RULES AND REGULATIONS 5 ❑ Prescriptive BUR -RAS 150 ROOF TYPE Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. Total (SF) RR 1111 I®P!!!® Inimm ■■EMS ■ ■! 11M" U: II 41121131 i���� ■■�•5 _ ammo 1111 mme mu•• munr40 ��. , FLORIDA BUILDING CODE — BUILDING awn' ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer: G40- Product Approval No.:O" 1 o2.. OZ Design Wind Pressures, From RAS 128 or Calculations: Pmax1: 1 p Pmax2: -1(•7 Pmax3: --lpR .0 Max. Design Pressurej from the specific Product Approval system:... tS Deck: Type: COnereit /De ��,� Ffsitit,1Gauge/Thickness: Slope: AnchorlBase Sheet & No. of Ply(s): P4/ 4 Anchor /Base Sheet Fast seer /Bonding Material: Pi Insulation Base Layer: ISO Base Insulation Size and Thickness, 2r+ Base Insulation Fastener Bonding M teri 1 I +Q}-� sna1- Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener /Bonding Material: ... Surfacing: Fastener Spacing for Anchor /Base Sheet Attachment: Field: T" oc Lap, # Rows = @ =" oc Perimeter: " oc @ Lap, # Rows = @," oc Corner: " oc @ Lap, # Rows = @ _" oc Number of Fasteners Per Insulation Board: Field Perimeter— Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit %- hteeOStP�,D,,� $p OC41"S ext 44/ FT. Ruben,'d a{r8 - waU Tht Base Sheet(s) & No. of Ply(s): Base Shee FastenerBpnding.Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet s ener/Borlding [illate llialphat ' e Top Ply: ► �.' �� .I �. �_ �.. le Top Piy F to er /Bonnop Majeria:_ FLORIDA BUILDING CODE — BUILDING Parapet Height_ _. I ' . ' FT. - _.. • 2%010)=1 Nadir ao4'd vif -1($ -p cow Mean Roof Height MIAMaDA� BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 08- 0108.06 and consists of pages 1 through 36. The submitted documentation was reviewed by Jorge L. Acebo () NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 1 of 36 ROOFING SYSTEM APPROVAL Category: Sub - Category: Deck Type: Maximum Design Pressure Roofing SBS /APP, Modified Bitumen Concrete -495 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Leak BusterTM MatrixTM 307 Premium Asphalt Primer GAF Mineral ShieldTM Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating Leak Buster"' MatrixTM 204 Wet/Dry Roof Cement Leak Buster"' Matrix"' 304 Non Fibered Aluminum Roof Coating GAFGLAS® #75 Base Sheet GAFGLAS® #80 ULTIMATM Base Sheet GAFGLAS® FIexPIyTM 6 GAFGLAS® Ply 4 Dimensions 3, 5, 55 gallons 60 lb. & 100 lb bags 5 gallons Test Product Specification Description ASTM D 41 Asphalt concrete primer used to promote adhesion of asphalt in built-up roofing. ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. ASTM 1227 Surface coating for smooth surfaced roofs. 1, 5 gallons ASTM D 2824 Fibered aluminum coating. 1, 5 gallons 5 gallons 39.37" (1 meter) Wide 39.37" (1 meter) Wide 3937" (1 meter) Wide 39.37" (1 meter) Wide ASTM D -4586 ASTM D -3409 ASTM D2824, Type I ASTM D 4601 Type II ASTM D4601 Type II ASTM D 2178 ASTM D 2178 Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. Non Fbered aluminum pigmented, asphalt roof coating. Asphalt impregnated and coated glass mat base sheet. Asphalt impregnated and coated, fiberglass base sheet. Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 2 of 36 Pro uct GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT® EliminatorTM Perforated Nailable RUBEROID® SBS Heat- We1dTM Smooth RUBEROID® SBS Heat- We1dTM Granule RUBEROID® SBS Heat WeIdTM 170 FR RUBEROID® EnergyCap SBS Heat Weld Plus FR RUBEROID® SBS Heat- WeIdTM PLUS RUBEROID® SBS Heat -Weld PLUS 170 FR RUBEROID® SBS Heat- We1dTM 25 RUBEROID® EnergyCap SBS 30 FR RUBEROID® MOP Smooth ULTRACLAD® SBS Foil -Faced Membrane RUBEROID® Modified Asphalt Lite RUBEROID® Modified Asphalt Plus Dimensions 39.37" (1 meter) Wide 39.37" (1 meter) Wide various 39.37" (1 meter) Wide 1 meter (39.37 ") wide 1 meter (39.37") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37") wide 1 meter (39.37") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 1 sq, roll 101 Ib. 60 Ib. kegs 60 lb. kegs Test Specification ASTM D 3909 ASTM D 3672 ASTM D 4897 ASTM D 3672 ASTM D 4897 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6163 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6163 ASTM D5147 ASTM D6298 ASTM D6298 ASTM D312 ASTM D6152 Product Description Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and smooth surfaced. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Non -woven polyester mat coated with polymer modified asphalt. Does not have a factory applied surfacing. Woven fiberglass mat coated with polymer modified asphalt and surfaced with aluminum, copper or stainless steel foil. SEBS modified asphalt SEBS modified asphalt NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 3 of 36 Pr uct RUBEROID® Modified Base Sheet RUBEROID® Mop Granule RUBEROID® Torch Smooth RUBEROID® Torch Plus (Granule) RUBEROID® Torch Granule RUBEROID® Torch FR RUBEROID® Mop Plus (Granule) RUBEROID® Mop FR RUBEROID® 20 RUBEROID® 30 RUBEROID® 30 FR RUBEROID® Mop 170 FR RUBEROID® SBS Dual FR Roof MatchTM APP Granular Roof MatchTM SBS Granular TopCoat® Surface Seal SB Leak BusterTM MatrixTM 715 MB Coating Test Dimensions Specification 39.37" (1 meter) ASTM D4601 Wide Type 11, Type G2 BUR 39.37" (1 meter) ASTM D 6164 Wide ASTM D 5147 39.37" (1 meter) ASTM D 6222 Wide ASTM D 5147 39.37" (1 meter) Wide 39.37" (1 meter) Wide 3937" (1 meter) Wide 39.37" (1 meter) Wide ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6164 ASTM D 5147 39.37" (1 meter) ASTM D 6164 Wide ASTM D 5147 39.37" (1 meter) ASTM D 6163 Wide ASTM D 5147 39.37" (1 meter) ASTM D 6163 Wide ASTM D 5147 39.37" (1 meter) ASTM D 6163 Wide ASTM D 5147 39.37" (1 meter) ASTM D 6164 Wide ASTM D 5147 39.37" (1 meter) ASTM D 6164 Wide ASTM D 5147 107 sq. ft. (9.9 m2) 107 sq. ft. (9.9 m2) 5 gallons 5 gallons ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 Product Description Premium glass fiber reinforced SBS- modified base sheet. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane. Heavy duty, polyester reinforced, asphalt modified bitumen membrane. Asphalt impregnated, coated felt, surfaced with mineral granules. Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with fire- retardant, polymer modified asphalt surfaced with mineral granules. SBS modified asphalt base sheet reinforce with a glass fiber mat. Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non woven fiberglass mat coated with fire retardant, polymer modified asphalt and surfaced with mineral granules.❑ Non -woven polyester mat coated with fire • retardant polymer modified asphalt surfaced with mineral granules. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with colored mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with colored mineral granules. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 4 of 36 Product TOPCOAT® MB Plus Leak Buster"' Matrix"' 531 WeatherCoteTM Leak Busterm Matrix''' 201 SBS Flashing Cement Leak Buster"' Matrix"' 102 SBS Adhesive Leak Buster"' Matrix""' 202 SBS Flashing Cement Leak Busterm Matrixm 203 Plastic Roof Cement Leak Buster"' Matrix"' 103 Gold Process Adhesive Vent Stacks (metal and plastic) EnergyCote® Roof Coating TOPCOAT® Surface Seal TOPCOAT® FireShield SB Solvent Base Elastomeric Roofing Membrane Dimensions 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons Test Specification Product Description AST' D -3412 Surface coating for smooth surfaced and ASTM D -21 -96 mineral surfaced roofs. AST' D -1475 ASTM E -1644 ASTM D -6083 Surface coating for smooth surfaced and mineral surfaced roofs. ASTM D3019 ASTM D3019 ASTM b4586 ASTM D4586 ASTM D3019 TAS 100(A) ASTM D 1929 ASTM D 635 Proprietary ASTM D-412 ASTM B -117 ASTM C -794 ASTM G -21 FTMS 141.6271 ASTM D -21 -96 ASTM D -1475 ASTM E-1644 ASTM D-412 ASTM B -117 ASTM C -794 ASTM G -21 FTMS141.6271 ASTM D -21 -96 ASTM D -1475 ASTM E -1644 Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement Cold Applied Asphalt Adhesive. One way valve vent used to relieve built -up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 5 of 36 APPROVED INSULATIONS: Product Name EnergyGuardTM RA, RN EnergyGuardTM Composite EnergyGuardTM Fiberboard EnergyGuardTM Polylso EnergyGuardTM Perlite EnergyGuardTM Recover Board EnergyGuardTM High Density Fiberboard EnergyGuardTM Ultra Polylso DensDeck® DensDeck Prime® DensDeck DuraGuardm SECUROCK® Structodek® APPROVED FASTENERS: Fastener Number 1. 2. Product Name TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate /wood fiberboard or perlite composite Fiberboard insulation Polyisocyanurate foam insulation Perlite insulation board. Perlite recover board High density wood fiberboard insulation. Polyisocyanurate foam insulation High Density Fire Resistant Insulation Boards High Density Fire Resistant Insulation Boards High Density Fire Resistant Insulation Boards High Density Fire Resistant Insulation Boards Wood fiber insulation board Drill -TecTM #12 Standard, #14 and #15 extra Heavy Duty Fastener , Heavy Duty Roofing Fastener Drill -TecTM ASAP 3. Drill -TecTM CR Base Sheet Fastener and Plate 4. Drill -TecTM Galvalume Plates 5. Drill -TecTM Polypropylene Plates 6. Drill -TecTM AccuTrac Plate Steel Plates TABLE 3 Product Description Manufacturer (With Current NOA) GAF Materials Corp GAF Materials Corp GAF Materials Corp GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. Georgia Pacific Georgia Pacific Georgia Pacific USG Knight Celotex Manufacturer Dimensions (With Current NOA) Insulation fastener and Various GAF Materials Corp. Base Play fastener for steel, wood & concrete decks. Pre- assembled Drill -TecTM Various GAF Materials Corp. Fasteners and metal and plastic plates. Base sheet fastening Various assembly. Round galvalume stress 3" and 31/2" plates. Round polypropylene 3" and 3 W stress plates. Square galvalume stress 3 x 3 plates. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 6 of 36 EVIDENCE SUBNIITTED: Test Agency/Identifier Factory Mutual Research Corp. Independent Roof Testing & Consulting of South Florida Exterior Research & Design, LLC Trinity I ERD Underwriters Laboratories, Inc. Name Current Insulation Attachment Requirements FMRC 4470 -TAS 114 FMRC 4470 - TAS 114 FMRC 4470 -TAS 114 FMRC 4470 - TAS 114 FMRC 4470 - TAS 114 FMRC 4470 -TAS 114 FMRC 4470 - TAS 114 FMRC 4470 - TAS 114 FMRC 4470 FMRC 4470 FMRC 4470 TAS 114 -J TAS 114 TAS 114 ASTM D6163 ASTM D6164 UL 790 -TAS 114 Report Date FMRC 1996 • 01.01.96 J.I.ODOA8.AM 07.09.97 J.I. 2B8A4.AM 07.02.97 J.I. 3005640 11.09.00 J.I. 3006845 10.17.00 J.I. 3005175 05.23.00 J.I.3005177 05.19.00 J.I.3007500 06.15.00 J.I. 3008178 12.27.00 J.I. 3010215 03.01.01 J.I. 3009788 03.28.01 3017250 04.05.04 No.00001 03.30.00 No.00002 #4483.04.97 -1 06 -06-97 #01881.09.03 -2 03.24.08 01881.11.03 -2 -RI 08.21.07 #66850.08.08 08.29.08 R1306, 00NK07638 07.17.00 NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25109 Page 7 of 36 APPROVED ASSEMBLIES: Membrane Type: SBS Deck Type 3: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(1): Insulation adhered with approved adhesive and membranes adhered to insulation. All General and System Limitations shall apply. One or more layers of any of the following insulations. Base Layer Insulation Insulation F - eners Fastener (Tab 3) Density /ftZ EnergyGuardTM Polylso, EnergyGnardTM UltraShield Minimum. 1.5" thick Note: Base layer shall be adhered with OlyBondTM at 1 gays coverage or OlyBond 500TM in 3/4" to 1" wide ribbons spaced 12" o.c. Insulation panels ' ' are minimum sizes and dimensions; if larger panels are used the number of faste rs per bo ; shall be increased maintaining the same fastener density (See Roofing Applicatio Stands. RAS 117 for fastening details). Top Layer Insulation _ Insulation Fasteners Fastener Density /ft2 Dens -Deck® Prime Minimum.' " thick N/A N/A Note: Apply top layer of insulation with Oly ndTM at 1ta1/sq full coverage or OlyBond 500TM in 3/4" to 1" wide ribbons spaced 12" o.c. Plea, refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed ase Layer only shall be used only as base Layers with a second Layer of approved top layer insu '' on installed as the final membrane substrate. Anchor Sheet: Two plies of GAFG S® #75 or a single ply of RUBEROID® 20, RUBEROID® Mop (Optional) Smooth RUBERO ►!'' Heat- WeldTM, RUBEROID® Heat We1dTM Smooth, GAFGLAS® UL ' Tm 80 two applied in hot asphalt full mop at 25 lbs /sq. Base Sheet: One or more es of RUBEROID® SBS, Heat- We1dTM Smooth, RUBEROID® SBS or Heat -Weld ° 25 torch applied. Ply Sheet: One or m plies of RUBEROID® SBS, Heat- WeldTM Smooth, RUBEROID® SBS or (optional) Heat -Weld 25 torch applied. Membrane: One or more plies RUBEROID® SBS HeatWeldTm PLUS, RUBEROID® SBS Heat - WeIdTM PLUS FR, RUBEROID® SBS Heat- We1dTM 170 FR, RUBEROID® EnergyCap SBS Heat Weld Plus FR, RUBEROID® SBS Heat WekIrm, RUBEROID® SBS Heat We1dTM Smooth and RUBEROID® SBS Heat WeldTM 25 torch applied. NOA No.: 08-1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 8 of 36 Surfacing: Optional, Required if RUBEROID® Heat- WeIdTM Mop Smooth or RUBEROID® Heat- We1dTM 25 is top membrane. 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 Ibs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galJsq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® EnergyCapTM Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs.sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 3 •, TOPCOAT® MB PLUS, TOPCOAT® Fireshield Elastomeric Roofing brave, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elasto c Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 " . /sq. 6. TOPCOAT® Surface Seal, TOPCOAT' F' `- shield® SB Solvent based Elastomeric Roofing Membrane appli ± _ Ito 1.5 gal./sq. 7. Advance Green Technologies Photo . }taic Laminate solar energy collector auxiliary roof equipment installed compliance with manufacturer's specifications and applicable B '. ry'+ing Codes. Maximum Design Pressure: -300 psf (See General Limitation' NOA No.: 08-1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 9 of 36 Membrane Type: SBS Deck Type 3: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(2): Insulation adhered with approved adhesive and membranes adhered to insulation. All General and System Limitations shall apply. One or more layers of any of the following insulations. Base Layer Insulation Insulation Fasteners Fastener Density /fly (Table 3) EnergyGuardTM PolyIso, EnergyGuardTM U1traShield Minimum. 15" thick N/A N/A Note: Base layer shall be adhered with OlyBondTM at 1 gal/sq full co #rage or OlyBond 500TH in 3/4" to 1" wide ribbons spaced 12" o.c. Insulation panels listed are inimum sizes and dimensions; if larger panels are used the number of fasteners pe 3 « « and shall be increased maintaining the same fastener density (See Roofing Applicatio Standard RAS 117 for fastening details). Top Layer Insulation ulation Fasteners Fastener Density /ft2 Dens - Deck ®Prime Minimum. l /a" thick N/A N/A (Table 3) Note: Apply top layer of insulation with OlyBon « at 1 gal/sq full coverage or OlyBond 500TH in 3/4" to 1" wide ribbons spaced 12" o.c. Pleas A • fer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as ase Layer only shall be used only as base layers with a second layer of approved top layer ins- lion installed as the final membrane substrate. (Optional) Anchor Sheet: (Optional) Base Sheet: Ply Sheet: Membrane: Two plies of GAFGLAS® full mop at 25 Ibs /sq. GAFGLAS® #75 appli -'in Matrix System Pro SBS Adhesive 102 at 1.5 gal/sq. 5 or GAFGLAS® #80 ULTIMATm applied in hot asphalt One or more RUBE '° OID® 20 RUBEROID Mop smooth applied In Matrix System Pro SBS Adhesive 10 : r 102 at 1.5 ga;/sq. One or more pli RUBEROID® 30, RUBEROID®30 FR, RUBEROID® EnergyCap SBS 30 FR, R EROID ® Mop Plus, RUBEROID® Mop 170 FR, RUBEROID® SBS Dual FR, R ROID® Mop Granule, Roof Match"' SBS Granular and RUBEROID® Mop Smoo « applied in Matrix System Pro SBS Adhesive 102 at a rate of 1.5 gal/sq. NOA No.: 08-1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 10 of 36 Surfacing: (Optional, Required if RUBEROID® Mop Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsJsq. and 300lbs.sq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® EnergyCapTM Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. 3. 3Leak BusterTM MatrixTM 303 Premium Fibered Al Roof Coating, at 1.5 gal./sq. 4. 4Leak BusterTM MatrixTM 715, Leak Buster"' M -. TM 322, TOPCOAT® MB PLUS, TOPCOAT® Fireshield Elastomeric R g Membrane, applied at 1 to 1.5 gal. /sq. 5. SLeak BusterTM MatrixTM 602 MB Xtra El : omeric Roofing Membrane, EnergyCote® roof coating applied at 1 toh.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOA Fireshield® SB Solvent based Elastomeric Roofing Membrane app ' . at Ito 1.5 gal./sq. 7. Advance Green Technologies Pho (voltaic Laminate solar energy collector auxiliary roof equipment install -in compliance with manufacturer's specifications and applicable B ding Codes. Maximum Design Pressure: -137.5 psf (See General Limitati ux #9) NOA No.: 08-1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 11 of 36 SYSTEMS A(3): ADHERED INSULATED SYSTEMS The following assembly is approved to a maximum design pressure per Insulation Maximum Design Pressure Table A. No substitutions shall be made: Deck Type: Concrete, primed. Anchor Sheet: Install one or more plies of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM, (Optional) GAFGLAS® PLY 4, GAFGLAS® FlexPlyTMp RUBEROID® Modified Base sheet RUBEROID® Mop Smooth or RUBEROID® 20 mopped directly to the substrate. Adhere with any approved mopping asphalt applied within the E / range and at a rate of 20-40 lbs./sq. Insulations: See Insulation Maximum Design Pressure Table A belo Design Pressure is dependent on Insulation assembly # used in this syste Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 £TIMATM GAFGLAS® PLY 4, GAFGLAS® FlexPlyTM 6, RUBEROID® Modified Sheet or RUBEROID® 20, RUBEROID® MOP Smooth, directly to the insul substrate. Adhere with any approved mopping asphalt applied within the range and at a rate of 20-40 lbs. /sq. Ply Sheet: One, two or three plies of RUBEROID® , GAFGLAS® PLY 4 or GAFGLAS® (Optional) F1exP1yTM 6 ply sheet adhered in a full mop ; g of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Membrane: One or more lies of RUBEROID® Toro Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule, R ROID® Torch ® FR, RUBEROID® Torch 170FR, Roof MatchTM APP Granul, /r RUBERO1D® 20, RUBEROID® MOP Smooth, RUBEROID® MOP Gran , RUBEROID® MOP 170FR, RUBEROID® SBS Dual FR, RUBEROID® ULTRA' AD" "i, RUBEROID® 30 and RUBEROID® 30FR, RUBEROID® EnergyCap SBS FR, RUBEROID® MOP PLUS and RUBEROID® MOP FR or RUBEROID® SB: eat- We1dTM PLUS, RUBEROID® SBS Heat- WeldTM PLUS FR, RUBEROID® S:'rHeat WeIdTM 170 FR, RUBEROID® EnergyCap SBS Heat Weld Plus FR, RUB ^ OID® SBS Heat We1dTM, RUBEROID® SBS Heat - WeldTM Smooth and R ;y ROID® SBS Heat- WeIdTM 25 applied according to manufacturer's applicat n instructions. Surfacing: (Optional) Install on of the following 1. Gravel or slag . lied at 400 lbs. /sq. and 300 lbs.sq. respectively in a flood coat of approved - , alt at 60 lbsJsq. or applied in a flood coat of Leak BusterTM MatrixTM 103 ld Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS ineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced C >. sheet adhered in a full mopping of approved asphalt applied within the EVT ge and at a rate of 20-40 lbs.sq. 3. Leak B -rTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak sterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB PLU TOPCOAT® FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 _alisq. 5. BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT' FireShield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq. 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02125/09 Page 12 of 36 Insulation Maximum Design Pressure Table A # Insulation Assemblies 1. Min. 1.5" EnergyGuardTM Composite RA, RN NP laid with the polyisocyanurate side down and bonded in a full mopping of an approved asphalt applied within the EVT range and at a rate of 20- 40 lbs. /sq. Maximum Desi . i Pressure —270 +: f See General Limitation #9 2. Base Layer: Min. 1" EnergyGuardTM RN. mopped in asphalt at the rate of 20-40 lbs./ Top Layer: Min. '/2" EnergyGuardTM Perlite adhered in a full mopping of approved . • halt applied within the EVT range and at a rate of 20-40 lbs. /sq. Maximum Design Pressure —322.5 psf (See General Limitation #9) 3. Base r er: Min. 1" Ener.. uardTM RA mo t, -. in : 'halt at the rate of ),-40 lbs./s • . Top Layer: Min. W' EnergyGuardTM High Density Wood Fiber Board (:4 adhered in a full mo..in of a• •roved : •halt : , .lied within the EVT ran and at a . of 20-40 lbs. +. Maximum Design Pressure 307.5 psf (See General Limitation r',. 4. Base / . er: Min. 1" Ener. GuardTM RA mo • , -. in as • halt at th f : to of 20 -40 Ibs ./s • Top Layer: Min. 1/2" EnergyGuardTM Perlite adhered in a full ping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs. /s•. Maximum Design Pressure —165 psf (See General Limi ;;f on #9) 5. Base Layer: Two Min. 3/4" layers EnergyGuardTM Peril . adhered in a full mopping of approved halt a, .lied within the EVT range and at a rate of 2; ' 0 Ibs ./s. . Top Layer: Min. '/a" Dens -Deck® mopped in asphalt :° the rate of 20-40 lbs. /sq.. Maximum Design Pressure —172.5 psf (See Genf Limitation #9) 6. (Optional) Base Layer: Min. 1.5" EnergyGuard RA, EnergyGuardTM RN or 1 /2" High Density Fiberboard secured to underlying substrate wi .. Insta-Stik Roofing Adhesive. Top Layer: One or more layers of Min. 1"E rgyGuardTM RN, EnergyGuardTM RA, 1 /2" High Density Fiberboard or Min. 1/4" Dens -Dec/ secured to underlying substrate with Insta-Stik Roofing Adhesive. Maximum Desi u , Pressure —112.5 + ' .(See General Limitation #9 7. Base + er: Min. 1" Ener a uardTM ` mo, . - , in as 'halt at the rate of 20- 401bsJs... op ' er: m. /2 ne A uar . ' ' igh Density Wood Fiber Board (c) adhered in a full mo • • in . of : • . roved • .. halt • , . ' . within the EVT ran . - and at a rate of 20-40 Ibs./ • . Maximum Design Pressure 2; .5 psf (See General Limitation 119) 8. (Optional) Base Layer: Min. 3 " EnergyGuardTM RN, EnergyGuardTM RA or 1 /2" High Density Fiberboard secured to under :, ing substrate with Insta -Stik Roofing Adhesive. Top Layer: One or more 1: ?ers of Min. 1" EnergyGuarddM RN, EnergyGuardTM RA, 1 /2" High Density Fiberboard, S . • • • ek or Min. 1/4" Dens -Deck secured to underlying substrate with Insta- Stik Roofing Adhesive. Maximum Design Pressure —105 psf (See General Limitation #9) 9. Min. 1.75" EnergyGuardTM Composite laid with the polyisocyanurate side down and bonded in a full mopping of an approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. Maximum Design Pressure —270 psf (See General Limitation 119) (yfltlulv�?�t•i4�i�1�J�1�1 APPROVED NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 13 of 36 10. Min. V EnergyGuardTM High Density Fiberboard or other Approved high density wood fiberboard or min. 1" EnergyGuardTM Perlite adhered in a full mopping of approved asphalt a' .lied within the EVT ran_ - and at a rate of 20- 401bsJs.. Maximum Design Pressure —140 psf (See General Limitation #9) 11. Base Layer: Min. 2" EnergyGuardTM RN Top Layer: Min. 'A" EnergyGuardTM Perlite adhered in a full mopping of appro ` s asphalt applied within the EVT range at a rate of 20-40 lbsJsq. Maximum Design Pressure —322.5 psf (See General Limitation #9) 12. Base Layer: Min. 1.5" EnergyGuardTM Composite Top Layer: Min. 1.5" EnergyGuardTM Composite adhered in a full m., r' . ing of approved asphalt • , 'lied within the EVT range and at a rate of 20-40 lbs./ • . . Maximum Design Pressure —270 psf (See General Limitation s') 13. Min. 3/4" EnergyGuardTM Perlite adhered to the primed concre deck in a full mopping of a, , roved as 'halt . • died within the EVT range at a rate of 2 0 lbsfs' . . Maximum Design Pressure —137 psf (See General Lim 'lion #9) 14. Base Layer: Min 1.5" EnergyGuardTM RA, EnergyGu - , r RN, EnergyGuardTM Composite adhered to the concrete deck in a full mopping of apps ed asphalt applied within the EVT range at a rate of 20- 401bs. /sq.. Top Layer: Min. W EnergyGuardTM Perlite adhe,,��' . to the base insulation layer or primed concrete deck in a full mopping of approved asp),(lt applied within the EVT range at a rate of 20- 40 lbs. /sq. Maximum Desi 1 1 Pressure —126 ' sf See general Limitation #9 15. Base Layer: Min. 11/4" EnergyGuardTM ' .. fir nergyGuardTM RN, EnergyGuardTM Composite adhered to the concrete deck in a full mo •,s■ ing of approved asphalt applied within the EVT range at a rate of 20-40 lbsJsq.. Top Layer: Min. W EnergyGuardTM . °berboard (c) or other approved wood fiberboard adhered to the base insulation layer or primed : crete deck in a full mopping of approved asphalt applied within the EVT range at a rate of 2'-40 lbsJsq. Maximum Design Pressure — 16;/psf (See General Limitation #9) 16. Base Layer: Min. 11/4" Energy • dTM RA, EnergyGuardTM RN adhered to the concrete deck in a full mopping of approved asp ,' t applied within the EVT range at a rate of 20-40 lbsJsq.. Top Layer: Min. 3 /a" Ene 3 %a uardTM Perlite or other approved perlite insulation board adhered to the base insulation layer or ' 'med concrete deck in a full mopping of approved asphalt applied within the EVT range at a -te of 20-40 lbsJsq.. Maximum Design P �:. ire —157 psf (See General Limitation #9) 17. Min.'' /Z" EnergyGuard Perlite adhered in a full mopping of approved asphalt applied within the EVT range and at a -. e of 20- 40lbs./sq. Maximum Design Pressure —90 psf (See General Limitation #9) 18. Min. 1.5" EnergyGuardrM Composite Deck is primed with GAF Asphalt/Concrete primer at a nominal rate of 0.75 ga/sq. Deck is covered with a RUBEROID® roof cover assembly fully adhered with hot asphalt applied at a minimum rate of 25 Ib /sq (1.2 kg/m2) Maximum Design Pressure -360 psf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 14 of 36 SYSTEMS A(4): ADHERED INSULATED SYSTEMS The following assembly is approved to a maximum design pressure per Insulation Maximum Design Pressure Table B. No substitutions shall be made: Deck Type: Concrete, primed. Anchor Sheet: Install one or more plies of GAFGLAS® #75, GAFGLAS® #80 ULTIMAT', (Optional) GAFGLAS® PLY 4, GAFGLAS® FIexP1yTM, RUBEROID® Modified Base sheet RUBEROID® Mop Smooth or RUBEROID® 20 mopped directly to primed deck. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbsisq. Insulations: See Insulation Maximum Design Pressure Table B below. Design Pressure is dependent on Insulation assembly # used in this system. Base Sheet: Install one ply of GAFGLAS® STRATAVENT® EliminatorTM Perforated, lose laid dry Ply Sheet: (Optional, required if membrane is APP /SBS Heat- We1dTM) One or more plies of RUBEROID® 20, GAFGLAS® PLY 4 or GAFGLAS® FlexPlyTM 6 ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq. Membrane: One or more plies of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule, RUBEROID® Torch FR, RUBEROID® Torch 170FR Roof MatchTM APP Granular or RUBEROID® 20, RUBEROID® MOP Smooth, R e, Roof MatchTM SBS Granular, RUBEROID® MOP 170FR, RUBEROID® SBS Dual FR, RUBEROID® ULTRACLADTm, RUBEROID® 30 and RUBEROID® 30FR, RUBEROID® EnergyCap SBS 30 FR, RUBEROID® MOP PLUS and RUBEROID® MOP FR or RUBEROID® SBS Heat- We1dTM PLUS, RUBEROID® SBS Heat- WeIdTM PLUS FR, RUBEROID® SBS Heat- We1dTM 170 FR, RUBEROID® EnergyCap SBS Heat Weld Plus FR, RUBEROID® SBS Heat- WekdTM, RUBEROID® SBS Heat- We1dTM Smooth and RUBEROID® SBS Heat We1dTM 25 applied according to manufacturer's application instructions. Surfacing: (Optional) Install one of the following I . Gravel or slag applied at 400 lbsisq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal.sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB PLUS, TOPCOAT® FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® FireShield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq. 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 15 of 36 Insulation Maximum Design Pressure Table B # Insulation Assemblies 1. Min. P' EnergyGuardTM RN, EnergyGuardTM RA mopped in asphalt at the rate of 20-40 lbsfsq. Maximum Design Pressure —150 psf (See General Limitation #9) 2. (Optional)Base Layer: Min. 1" EnergyGuardTM RN, EnergyGuardTM RA mopped in asphalt at the rate of 20-40 lbs. /sq. Top Layer. Min. ' 4" Dens -Deck mopped in asphalt at the rate of 20-40 lbs./sq.. Maximum Design Pressure —240 psf (See General Limitation #9) 3. (Optional) Base Layer: Min. 1" EnergyGuardTM RN, EnergyGuardTM RA, EnergyGuardTM Comppsite, EnergyGuardTM Composite, mopped in asphalt at the rate of 20-40 lbsisq. Top Layer: Min. 3/4" EnergyGuardTM perlite or other approved perlite insulation board or Min. 'A" EnergyGuardTM High Density Fiberboard (c) or other approved High Density wood fiberboard or Min. 1" EnergyGuardTM Fiberboard (c) or other approved wood fiberboard adhered to the base insulation layer or primed concrete deck in a full mopping of approved asphalt applied within the EVT range at a rate of 20-40 lbs. /sq. Maximum Design Pressure —90 psf (See General Limitation #9) 4. (Optional) Base Layer: Min. 1" EnergyGuardTM RN, EnergyGuardTM RA, EnergyGuardTM Composite mopped in asphalt at the rate of 20-40 lbs./sq. Top Layer: Min. 3l4" EnergyGuardTM perlite or other approved perlite insulation board Min. 'A" EnergyGuardTM High Density Fiberboard (c) or other approved High Density wood fiberboard EnergyGuardTM Fiberboard (c) or other approved wood fiberboard adhered to the base insulation layer or primed concrete deck in a full mopping of approved asphalt applied within the EVT range at a rate of 20- 40lbs. /sq.. Maximum Design Pressure —90 psf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 16 of 36 Membrane Type: Deck Type 3: Deck Description: System Type B: SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank Base sheet adhered with approved asphalt base insulatio ayer mechanically fastened, optional top layer adhered with approved asp - lt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer (Table 2) (When applicable: Steel plate only =S, plastic plate only =P) EnergyGuardTM Polylso, EnergyGuardTM Composite, Ene Minimum. 2" thick Note: Base layer shall be mechanically attached with panels listed are minimum sizes and dimensions; if per board shall be increased maintaining the same Standard RAS 117 for fastening details). GAF STRATAVENT® Eliminator"' Perforated laid wood fiber overlay board on all polyisocyanu Insulation for Top Layer (Table 2) Any of the insulations listed for Base Note: Apply top layer of insulation the EVT range and at a rate of 2 RAS 117 for insulation attachmen base layers with a second layer of substrate. Composite insulation polyisocyanurate side facing do Base Sheet: Install on PLY 4, Perfo di app Ply Sheet: (Optional) Membrane: ns'on Fasteners (Table 3) nardTM RA, RN 1S or 6 Fastener Density/ft2 1:1.45 teners and density described. Insulation er panels are used the number of fasteners tener density (See Roofing Application r "uires either a ply of GAFGLAS ry or a layer of EnergyGuard® PERLITE or to applications. er, above. Insulation Fasteners (Table 3) N/A Fastener Density/ft2 N/A full mopping of any approved mopping asphalt within bs/100 ft2. Please refer to Roofing Application Standard sulation listed as Base Layer only shall be used only as pproved top layer insulation installed as the final membrane anels may be used as a top layer placed with the n. ly of GAFGLAS® #75, GAFGLAS® #80 ULTIMA"�, GAFGLAS® AFGLAS® FlexP1yTM 6, GAFGLAS® STRATAVENT® Eliminators laid dry, RUBEROID® Modified Base Sheet or RUBEROID® 20 to the insulated substrate. Adhere with any approved mopping asphalt within the EVT range and at a rate of 20-40 lbsisq. e or more plies of GAFGLAS® Ply 4, GAFGLAS F1exPlyTM 6 ply sheets or AFGLAS'' #80 ULTIMA' Base Sheet. Adhere with any approved mopping phalt applied within the EVT range and at a rate of 20-40 lbsisq. One or moreplies ply of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® SBS Dual FR, RUBEROID® Mop Plus Granule, RUBEROID® Mop FR, RUBEROID® UltraClad, RUBEROID® 20, RUBEROID® 30, RUBEROID® 30 FR Roof MatchTM SBS Granular or RUBEROID® EnergyCap SBS 30 FR. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 17 of 36 Surfacing. (Optional, required over RUBERROID® 20 or RUBEROID® MOP Smooth) Install one of the following: 1. Gravel or slag applied at 400 lbs.sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate • 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Ene . Cap Mineral Surfaced Capsheet adhered in a full mopping of approved phalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Al um Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715, Leak Buster"' M. TM 322, TOPCOAT® MB PLUS, TOPCOAT® FireShield Elastomeric ' ":fing Membrane, applied at 1 to 1.5 gal.lsq. 5. Leak BusterTM MatrixTM 602 MB Xtra El,.` omeric Roofing Membrane, EnergyCote® roof coating applied at 1 t.' .5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOA Elastomeric Roofing Membrane ap 7. Advance Green Technologies Ph auxiliary roof equipment install specifications and applicable Maximum Design Pressure: -67.5 psf (See General Limi :/ on #7) FireShield® SB Solvent based ed at lto 1.5 gal. /sq. voltaic Laminate solar energy collector in compliance with manufacturer's riding Codes NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 18 of 36 Membrane Type: APP & SBS Heat-Weld Deck Type 3: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type C(1): All layers of insulations are mechanically attached to roof deck. Membrane is subsequently fully or partially adhered to insulation. All General and System Limitations shall apply. Insulation for Base Layer. (Table 2) Insulation F (Tabl EnergyGuardTM Polybo, EnergyGuardTM Composite, EnergyGuardrm Minimum 1.5" thick Note: All layers shall be simultaneously fastened; see top layer belo Insulation panels listed are minimum sizes and dimensions; if larg of fasteners shall be increased maintaining e same fastener densi`. Application Standard RAS 117 for insulation attachment. Insulation for Top Layer (Table 2) (When applicable: Steel plate only =S, plastic plate only P) Dens Deck Minimum'/" thick Base Sheet: Ply, Sheet: Membrane: ners Fastener Density /ft2 N/A for fasteners and density. panels are used, the number Please refer to Roofing ulation Fasteners Fastener (Table 3) Density /ft 1S, 6 1:1 Install one ply of GAFGLAS® S ' E AVENT® EliminatorTM Perforated loose laid dry. One or more plies of GAFGLASc`' Ply 4, GAFGLAS® F1exP1yTM 6 ply sheets or GAFGLAS® #80 ULTIMA' 0 _ Sheet. Adhere with any approved mopping asphalt applied within the EV range and at a rate of 20-40 lbs./sq. One or more plies of RUB RUBEROID® Torch Plus APP Granular. Torch ap Or One or more plies of Heat -Weld 25, RUB SBS Heat Weld P1 SBS Heat- WeIdTM OID® Torch Smooth, RUBEROID® Torch Granule, ule, RUBEROID® Torch FR or Roof MatchTM ed according to manufacturer's application instructions. EROID® SBS Heat- We1ddM Smooth, RUBEROID® SBS OID® SBS Heat- We1dTM 170 FR, RUBEROID® EnergyCap FR, RUBEROID® SBS Heat -Weld PLUS, or RUBEROID® LUS FR heat welded. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 19 of 36 Surfacing: Maximum Design Pressure: -82.5 psf (See General Limitati„ #7) (Optional, required over RUBEROID® SBS Heat- We1dTM Smooth) Install on a of the following: 1. Gravel or slag applied at 400 lbs.sq. and 300 lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak Buster"' Matrix"' 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak BusterTM Matrix"' 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal /sq. 4. Leak Busterm Matrix"' 715, Leak Buster"' Matrix ; 22, TOPCOAT > MB PLUS, TOPCOAT® FireShield Elastomeric Roo . �' . embrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elasto1$'ric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 . al./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® F. eShield® SB Solvent based Elastomeric Roofing Membrane appli fi;- t Ito 1.5 gal. /sq. 7. Advance Green Technologies Photov 4 ` : is Laminate solar energy collector auxiliary roof equipment installed in mpliance with manufacturer's specifications and applicable Buil.' +g Codes NOA No.: 08-1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 20 of 36 Membrane Type: Deck Type 3: Deck Description: System Type C(2): SBS Concrete Decks, Insulated 2500 psi structural concrete or concrete plank All layers of insulations are mechanically attached roof deck. Membrane is subsequently fully or partially adhered to insulation. All General and System Limitations shall apply. Insulation for Base Layer (Table 2) Insulation F (Tab EnergyGuardTM Polylso, EnergyGuardTM Composite, EnergyGuardTM Minimum 1.5" thick Note: All layers shall be simultaneously fastened; see top layer bel Insulation panels listed are minimum sizes and dimensions; if la of fasteners shall be increased maintaining e same fastener dens Application Standard RAS 117 for insulation attachment. Insulation for Top Layer (Table 2) (When applicable: Steel plate only =S, plastic plate only =P) Dens Deck Minimum %" thick Base Sheet: Ply Sheet: (Optional) Membrane: ners Fastener Density /ft2 N/A for fasteners and density. r panels are used, the number . Please refer to Roofing nsulation Fasteners Fastener (Table 3) Density /ft2 1S, 6 1:1 Install one ply of GAFGLAS® S TAVENT® EliminatorTM Perforated loose laid dry. One or more plies of RUBE FIexPIyTM 6 ply sheets or Cx any approved mopping lbsJsq. One or more plies ply Mop Granule, RUB RUBEROID® Mo Granular, RUBE EnergyCap S13 the EVT rang ID® 20, GAFGLAS® Ply 4 or GAFGLAS® GLAS® 1480 ULTIMATM Base Sheets. Adhere with t applied within the EVT range and at a rate of 20-40 RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® OID® Mop 170 FR, RUBEROID® SBS Dual FR, us Granule, RUBEROID® Mop FR, Roof MatchTM SBS ID® UltraCladTM, RUBEROID® 30 FR or RUBEROID® 0 FR,. Adhere with any approved mopping asphalt applied within d at a rate of 20-40 Ibs./sq. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 21 of 36 Surfacing: Maximum Design Pressure: -82.5 psf (See General L. tation #7) (Optional, required over RUBEROID® 20 or RUBEROID® MOP Smooth) install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gat/sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of appro . asphalt applied within the EVT range and at a rate of 20- 401bs.sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered A gal. /sq. 4. Leak Buster"' MatrixTM 715, Leak Buster PLUS, TOPCOAT® FireShield Elastome 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB X lastomeric Roofing Membrane, EnergyCote® roof coating applied ato 1.5 galfsq. TM 322, TOPCOAT® MB oofmg Membrane, applied at 1 to 6. TOPCOAT® Surface Seal, TOPC AT° FireShield® SB Solvent based Elastomeric Roofing Membrane, plied at Ito 1.5 gal.sq. 7. Advance Green Technologie '' hotovoltaic Laminate solar energy collector auxiliary roof equipment in f ed in compliance with manufacturer's specifications and applica = e Building Codes IAPPROVEDI NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 22 of 36 Membrane Type: APP & SBS Heat -Weld Deck Type 3: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(1): All insulations are loose laid with preliminary attachment to roof deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. Insulation Layer (Table 2) Insulation Fasteners => Fastener (Table 3) Density/ft2 EnergyGuardTM Polylso, EnergyGuardTM Composite, EnergyGuardTM RA, Minimum 1.3" thick N/A N/A EnergyGuardTM High Density Fiberboard Minimum 1" thick N/ N/A Note: All layers of insulation and base sheet shall be simultaneously ", ched. See base sheet below for fasteners and density. Refer to Roofing Application Stan N d RAS 117 for insulation attachment requirements. Insulation shall have preliminary attar 4 ent, prior to the installation of the roofing membrane. All insulation shall be adhered to the k in two g /a" beads of Insta -Stik adhesive space at 12" o.c. Base Sheet: Install one ply of GAFGLAS® #75, GAF S® #80 ULTIMAT", GAFGLAS® PLY 4, GAFGLAS FlexPlyTM 6, GAFG / S® STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Bas heet or RUBEROID® 20. Fastened to the deck through the insulation with Dri s ecTM #14 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Pla in a 2" side laps 12" on center. Three rows are equally spaced approximate) °' " o.c. in the field of the sheet spaced 12 o.c. along the length of the sheet. Ply Sheet: (Optional, required if used f RUBEROID® 20 or perforated STRATAVENT®) One or more plies of GAF e S® Ply 4, GAFGLAS® FIexPl TM 6 1 sheets or ® _,� Y ply GAFGLAS® #80 ULT 1 % Base Sheet. Adhere with any approved mopping . Y PP PP g asphalt applied within ; a EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies o UBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Tor . ' Plus Granule, RUBEROID® Torch FR or Roof MatchTM APP Granular. T . h applied according to manufacturer's application instructions. Or One or more ies of RUBEROID® SBS Heat- We1dTM Smooth, RUBEROID® SBS Heat -Wel . ' 25, RUBEROID® SBS Heat- WeldTM 170 FR, RUBEROID® Energy . SBS Heat Weld Plus FR, RUBEROID® SBS Heat- WeIdTM PLUS, or RUBE - ! ID® SBS Heat- We1dTM PLUS FR heat welded. NOA No.: 08-1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 23 of 36 Surfacing: (Optional, required over RUBEROID® SBS Heat- We1dTM Smooth) Install one of the following: 1. Gravel or slag applied at 400 lbs.sq. and 300lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs.sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt a ' ied within the EVT range and at a rate of 20- 401bsJsq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum R. ..d oating, at 1.5 gal./sq. 4. Leak BusterrM MatrixTM 715, Leak BusterTM MatrixTM 32 , OPCOAT® MB PLUS, TOPCOAT® FireShield Elastomeric Roofmg M rane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric °`oofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./:F� 6. TOPCOAT® Surface Seal, TOPCOAT® FireS, ' d® SB Solvent based Elastomeric Roofmg Membrane applied at II 1.5 gal./sq. 7. Advance Green Technologies Photovoltai nate solar energy collector auxiliary roof equipment installed in co iance with manufacturer's specifications and applicable Building bodes Maximum Design Pressure: -60 psf (See General Limitation #7) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 24 of 36 Membrane Type: SBS Deck Type 3: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(2): All insulations are loose laid with preliminary attachment to roof deck. Base sheet is subsequently mechanically fastened through insulation to th . oof deck. All General and System Limitations shall apply. Insulation Layer (Table 2) Insulation Fasteners " Fastener (Table 3) ., Density /fia EnergyGuardTM Polylso, EnergyGnardTM Composite, EnergyGuardTM RA, Minimum 13" thick N/A ;' N/A EnergyGuardTM High Density Fiberboard Minimum 1" thick N/ N/A Note: All layers of insulation and base sheet shall be simultaneously! ttached. See base sheet below for fasteners and density. Refer to Roofing Application S and RAS 117 for insulation attachment requirements. Insulation shall have preliminary a ment, prior to the installation of the roofing membrane. All insulation shall be adhered to tk deck in two %" beads of Insta Stik adhesive space at 12" o.c. Base Sheet Install one ply of GAFGLAS® #75, GAY' LAS® #80 ULTIMATM, GAFGLAS® PLY 4, GAFGLAS® FIexP1yTM 6, GAFGL STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet y RUBEROID® 20. Fastened to the deck through the insulation with Drill -Tin` TM # 14 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates ; '` a 2" side laps 12" on center. Three rows are equally spaced approximately o.c. in the field of the sheet spaced 12 o.c. along the length of the sheet. Ply Sheet: One or more plies of GAF AS® Ply 4, GAFGLAS® F1exPlyTm 6 ply sheets or (Optional) GAFGLAS® #80 ULT t 'Base Sheets. Adhere with any approved mopping asphalt applied within ►''- EVT range and at a rate of 20-40 lbsisq. Membrane: One or more plies ply „ RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® Mop Granule, RUB OID® Mop 170 FR, RUBEROID® SBS Dual FR, RUBEROID® Mop Plus Granule UBEROID® Mop FR, Roof MatchTM SBS Granular RUBEROID® U s C1adTm, RUBEROID® 30, RUBEROID®30 FR or RUBEROID® EnergyCap SBS 30 FR,. Adhere with any approved mopping asphalt applied within the EVT ran : and at a rate of 20-40 lbsisq. NOA No.: 08-1028.02 Expiration Date: 11 /06/13 Approval Date: 02/25/09 Page 25 of 36 Surfacing: (Optional, required over RUBEROID® 20 or RUBEROID® MOP Smooth) install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asp . t applied within the EVT range and at a rate of 20-40 Ibs.sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Alumin gal. /sq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM Matri 322, TOPCOAT® MB PLUS, TOPCOAT® FireShield Elastomeric Roofi g Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak Buster"' MatrixTM 602 MB Xtra Elast9 eric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1 galisq. 6. TOPCOAT® Surface Seal, TOPCOAT® Shield® SB Solvent based Elastomeric Roofing Membrane appli -t at Ito 1.5 gal. /sq. 7. Advance Green Technologies Photo ltaic Laminate solar energy collector auxiliary roof equipment installed r- `compliance with manufacturer's specifications and applicable Bu F. ing Codes oof Coating, at 1.5 Maximum Design Pressure: -60 psf (See General Limitation APPROVED NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 26 of 36 Membrane Type: APP & SBS Heat -Weld Deck Type 3: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(3): All insulations are loose laid with preliminary attachment to roof deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. Insulation Layer (Table 2) Insulation Fast "ers Fastener (Table/ Densitylft2 EnergyGuardTM PolyIso, EnergyGuardTM Composite, EnergyGuardTM ' Minimum 1.3" thick R, A N/A EnergyGuardTM High Density Fiberboard Minimum 1" thick N/A N/A Note: All layers of insulation and base sheet shall be simultaneo attached. See base sheet below for fasteners and density. Refer to Roofing Application Stand <' RAS 117 for insulation attachment requirements. Insulation shall have preliminary' 'ttachment, prior to the installation of the roofing membrane. All insulation shall be adhered to :''e deck in two 3/" beads of Insta -Stik adhesive space at 12" o.c. Base Sheet: Install one ply of SBS Heat- We1dT"" mooth. Fastened to the deck through the insulation with Drill-Tech #14 Sp ws and EverGuard"" 2" Barbed Plates in a 4" side laps 6" on center. Lap is t• h sealed according to manufacture's instructions. Ply Sheet: One or more plies of RUBE'. ID® Heat- We1dTM Smooth. Adhere with any (Optional) approved mopping asphalt2i plied within the EVT range and at a rate of 20-40 lbs. /sq. Membrane: One or more plies of EROID® SBS Heat-Weld"' Smooth, RUBEROID® SBS Heat- We1dTM 25, R !: ROID® SBS Heat-WeIdTM 170 FR, RUBEROID® EnergyCap SBS Heat Weld P FR, RUBEROID® SBS Heat- WeldTm PLUS, or RUBEROID® SBS Heat-Weld 'LUS FR heat welded. Applied according to manufacturer's application i ctions. NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 27 of 36 Surfacing: (Optional, required over RUBEROID® SBS Heat- We1dT' Smooth) Install one of the following: l . Gravel or slag applied at 400 lbs. /sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak Buster"' MafrixTM 103 Cold Process Adhesive applied at a rate of 3 galisq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt appli- ithin the EVT range and at a rate of 20-40 lbs./sq. 3. Leak Buster"' MatrixTM 303 Premium Fibered Aluminum Roof . '' ng, at 1.5 gal./sq. 4. Leak BusterTM Matrix"' 715, Leak BusterTM MatrixTM 322, T �sre' COAT® MB PLUS, TOPCOAT' FireShield Elastomeric Roofing Memb e, applied at 1 to 1.5 gal. /sq. 5. Leak Buster"' Matrix"' 602 MB Xtra Elastomeric R. r ng Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® FireShiel •TSB Solvent based Elastomeric Roofing Membrane applied at lto 1 galisq. 7. Advance Green Technologies Photovoltaic Latinate solar energy collector auxiliary roof equipment installed in compli ce with manufacturer's specifications and applicable Building Co Maximum Design Pressure: -82.5 psf (See General Limitation #7) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 28 of 36 Membrane Type: Deck Type 3I: Deck Description: System Type F(1): APP Concrete Decks, Non - insulated 2500 psi structural concrete or concrete plank Base sheet adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: (Optional) Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: 4,121,1:0.1))40o,..1.;:114 APPROVED Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA GAFGLAS® PLY 4, GAFGLAS® FIexP1yTM 6, RUBEROID® Modified B ` Sheet or RUBEROID® 20 directly to primed deck. Adhere with any .. 'roved mopping asphalt applied within the EVT range and at a rate of 20 -4 bs. /sq. (Optional, required if used with RUBEROID® 20) One a more plies of GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6 ply sh for GAFGLAS® #80 ULTIMA' Base Sheet. Adhere with any approve. opping asphalt applied within the EVT range and at a rate of 20-40 Ibs.// One or moreplies of RUBEROID® Torch Sm.�'`th, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule, RUBERR3ID® Torch FR or Roof MatchTM APP Granular. Torch applied according to anufacturer's application instructions. (Optional) Install one of the following: 1. Gravel or slag applied at 4001bs. /: . and 300 Ibs.sq. respectively in a flood coat of approved asphalt at 60 lb : Isq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold ' ess Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfa ' Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhere4 n a full mopping of approved asphalt applied within the EVT range and 'at a rate of 20-40 lbsisq. 3. Leak BusterTM Matrix 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM Ma TM 715, Leak BusterTM Matrix"( 322, TOPCOAT® MB PLUS, TOPCOA ` FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM! "` atrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® oof coating applied at 1 to 1.5 gal. /sq 6. TOPCOA ; pSurface Seal, TOPCOAT® FireShield® SB Solvent based Elastome Roofing Membrane applied at lto 1.5 gal. /sq. 7. Advan reen Technologies Photovoltaic Laminate solar energy collector auxili : roof equipment installed in compliance with manufacturer's spec','' cations and applicable Building Codes -23 sf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 29 of 36 Membrane Type: Deck Type 3I: Deck Description: System Type F(2): APP Concrete Decks, Non - Insulated 2500 psi structural concrete or concrete plank Base sheet adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: -45 5 psf (See General Limitation #9) Install one ply of GAFGLAS ® #75, GAFGLAS® #80 ULTIMATM, AFGLAS® PLY 4, GAFGLAS® F1exPlyTM 6, RUBEROID® Modified Bas y heet or RUBEROID® 20 directly to primed deck. Adhere with any a;,, roved mopping asphalt applied within the EVT range and at a rate of 20-4 V :' V. sJsq. (Optional, required if used with RUBEROID® 20) One more plies of GAFGLAS® Ply 4 or GAFGLAS® F1exP1yTM 6 ply s Adhere with any approved mopping asphalt appli. s . ithin the EVT range and at a rate of 20- 40lbs.sq. One ormore1lies of RUBEROID® Torch Sm•; , RUBEROID® Torch Granule, RUBEROID Torch Plus Granule, RUBERO y ® Torch FR or Roof MatchTM APP Granular. Torch applied according to g ufacturer's application instructions. (Optional) Install one of the following: 1. Gravel or slag applied at 400 lbs./ =-wand 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 Ib• sq. or applied in a flood coat of Leak BusterTM Matrix-1'm 103 Cold Pr. Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfa + Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered a full mopping of approved asphalt applied within the EVT range an.,�� a rate of 20-40 IbsJsq. 3. Leak BusterTM MatrixT" 03 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM Ma TM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB PLUS, TOPCOA ' FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak Buster ,!° atrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote ®' .. f coating applied at 1 to 1.5 galJsq. 6. TOPCOA4. ``' Surface Seal, TOPCOAT® FireShield® SB Solvent based Elastom "' c Roofing Membrane applied at lto 1.5 gal./sq. Green Technologies Photovoltaic Laminate solar energy collector roof equipment installed in compliance with manufacturer's fications and applicable Building Codes NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 30 of 36 Membrane Type: Deck TyFe 31: Deck Description: SBS Concrete Decks, Non - Insulated 2500 psi structural concrete or concrete plank System Type F(3): Base sheet adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #8 & TIMATM, Base Sheet GAFGLAS® PLY 4, GAFGLAS® FlexPly 6, R ®�.t" OID® Modified Base Sheet or RUBEROID® 20 directly to primed deck. A. ere with any approved mopping asphalt applied within the EVT range and at - to of 20-40 lbsisq. Ply Sheet: One or more plies of GAFGLAS® Ply 4, GLAS® F1exPly 6 ply sheets or (Optional) GAFGLAS® #80 ULTIMATM, Base S - t. Adhere with any approved mopping asphalt applied within the EVT ran.: d at a rate of 20-40 lbsisq. Membrane: One or more plies ply of RUBER e i ® 20, RUBEROID® MOP Smooth, RUBEROID® Mop Granule, R E ROID® Mop 170 FR, RUBEROID® SBS Dual FR, RUBEROID® Mop Plus G. ule, RUBEROID® Mop FR, Roof MatchTM SBS Granular, RUBEROID® UL CLADTM, RUBEROID®30, RUBEROID®30 FR or RUBEROID®Energy SBS 30 FR. Adhere with any approved mopping asphalt applied within th u; VT range and at a rate of 20-40 lbs.sq. Surfacing: (Optional, required ovJ RUBEROID® MOP Smooth) Install one of the following: 1. Gravel or slat pplied at 400 lbsisq. and 300 lbsisq. respectively in a flood coat of appr5 ed asphalt at 60 lbs.sq. or applied in a flood coat of Leak BusterTM trixTM 103 Cold Process Adhesive applied at a rate of 3 1./sq. 2. GAFGL:+ ® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfac ! Capsheet adhered in a full mopping of approved asphalt applied with' e EVT range and at a rate of 20-40 lbs. /sq. 3. - BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1 gal./sq. 4. BusterTM Matrix"M 715, Leak Buster"' Matrixm 322, TOPCOAT® PLUS, TOPCOAT® FireShield Elastomeric Roofing Membrane, applied at I to 1.5 gal. /sq. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofmg Membrane, EnergyCote® roof coating applied at 1 to 1.5 galisq. TOPCOAT® Surface Seal, TOPCOAT® FireShield® SB Solvent based Elastomeric Roofing Membrane applied at ito 1.5 gal./sq. 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes Maximum Design Pressure: -457.5 psf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 31 of 36 Membrane Type: SBS Deck Type 3: Concrete Decks, Non - Insulated Deck Description; 2500 psi structural concrete or concrete plank System Type F(4): Base sheet adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULT GAFGLAS® PLY 4, GAFGLAS® FlexPlyTM 6, RUBERO Sheet, RUBEROID® MOP Smooth or RUBEROID® 20 Adhered with MatrixTM 102 Select SBS Adhesive (R Bitumen Adhesive) at an application rate of 1 -2 gal Base Sheet Modified Base ectly to primed deck. ROID® Modified Membrane: One or moreeplies ply of RUBEROID® MOP S z t • th, RUBEROID® Mop Granule, RUBEROID Mop 170 FR, RUBEROID® SB `4 FR, RUBEROID® Mop Plus Granule, RUBEROID® Mop FR, Roof Mate SBS Granular, RUBEROID®30, RUBEROID®30 FR or RUBEROID® Ene p SBS 30 FR. Adhered with MatrixTM 102 Select SBS Adhesive (R EROID®Modified Bitumen Adhesive) at an application rate of 1 -2 gal. /sq. Surfacing: (Optional, required over RUBER •,l l r ® MOP Smooth) Install one of the following: 1. Gravel or slag applied at 4 t lbsisq. and 3001bs. /sq. respectively in a flood coat of approved asphal, 60 lbs.sq. or applied in a flood coat of Leak BusterTM MatrixTM 10r old Process Adhesive applied at a rate of 3 galisq. 2. GAFGLAS® Mine Surfaced Capsh within the EVT Maximum Design Pressure: urfaced Cap Sheet, GAFGLAS® Energy Cap Mineral ered in a full mopping of approved asphalt applied ge and at a rate of 20-40 lbs.sq. 3. Leak BusterTM atrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak Bust Menu"' 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB PLUS, Tu ' COAT® FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 Jsq. 5. Leak , " erTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, Ene a`L ote® roof coating applied at 1 to 1.5 gal. /sq. 6. T COAT® Surface Seal, TOPCOAT® FireShield® SB Solvent based astomeric Roofing Membrane applied at 1to 1.5 gal. /sq. 7 .' Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes -307.5 psf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 32 of 36 Membrane Type: SBS Deck Type 3: Concrete Decks, Non - Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F(5): Membrane fully adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: GAFGLAS® STRATAVENT® EliminatorTM Perfora oose laid dry over primed concrete deck. Ply Sheet: One or more plies of RUBEROID® 20, GAFGLA '` #80 ULTIMATm, GAFGLAS® (Optional) PLY 4 or GAFGLAS® FlexPlyTM 6 ply sheet. A - red in a full mopping of approved asphalt applied within the EVT rang -s d at a rate of 20-40 lbsisq Membrane: One or more plies of RUBEROID® 20, RU ROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID® SBS Dual F /UBEROID ®Mop Granule, RUBEROID® Mop Plus Granule, Roof tchTM SBS Granular, RUBEROID® 30, RUBEROID® 30 FR, RUBEROID® E '" gyCap SBS 30 FR, RUBEROID® Mop FR or RUBEROID® UltraCladTM SBS. . ered in a full mopping of approved asphalt applied within the EVT range and a rate of 20-40 lbsisq Surfacing: (Optional, required over RUBE, • ID® 20 and RUBEROID® MOP Smooth) Install one of the following: 1. Gravel or slag applied a 00 Ibs. /sq. and 300lbs.sq. respectively in a flood coat of approved asph -4 at 60 lbsisq. or applied in a flood coat of Leak BusterrM MatrixTM 1 a' Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mine Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsh adhered in a full mopping of approved asphalt applied within the EVT , ge and at a rate of 20-40 Ibs.sq. 3. Leak BusterT I . trixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak Busted' MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB PLUS, T f ' COAT® FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./ 5. Leak erTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, Ener'Cote® roof coating applied at 1 to 1.5 gal./sq. 6. TO OAT® Surface Seal, TOPCOAT® FireShield® SB Solvent based El" omeric Roofing Membrane applied at lto 1.5 gal./sq. 7. vane Green Technologies Photovoltaic Laminate solar energy collector uxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes Maximum Design Pressure: -195 psf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 33 of 36 • Membrane Type: APP /SBS Heat Weld Membrane Type: APP & SBS Heat -Weld Deck Type 3: Concrete Decks, Non - Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F(6): Membrane fully adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: GAFGLAS® STRATAVENT® EliminatorTM Perfo :A 1'`- d, loose laid dry over primed concrete deck. Ply Sheet: One or more plies of GAFGLAS® #80 ULT 1 < Base Sheets or GAFGLAS® #75 Base Sheet adhered in a full mopping of app %ved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq. Adhe in a full mopping of approved asphalt applied within the EVT range and at a of 20-40 Ibs./sq. Membrane: One or more plies of RUBEROID® T. ' h Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule o UBEROID® Torch FR, RUBEROID® Torch 170 FR or Roof MatchTM APP : lar torch applied according to manufacturer's application instructions. OR RUBEROID® SBS Heat -Wel4 Smooth, RUBEROID® SBS Heat- WeIdTM FR, RUBEROID® SBS Heat W- dTM Plus FR, RUBEROID® SBS Heat- We1dTM 25, RUBEROID® SBS Heat -' !IdTM Granule, RUBEROID® SBS Heat- WeldTM 170 FR, RUBEROID® Ener :p SBS Heat Weld Plus FR, RUBEROID® SBS Heat - We1dTM Plus FR, RUB OID® UltraCladTM. Applied according to Manufacturer's application instructio Surfacing: (Optional, required er RUBEROID® SBS Heat- WeIdTM Smooth) Install one of the following: 1. Gravel or s1• applied at 400 lbs./sq. and 300 Ibs./sq. respectively in a flood coat of app .ved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM ` : trixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGL ® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surf. Capsheet adhered in a full mopping of approved asphalt applied withi .'.i e EVT range and at a rate of 20-40 lbs./sq. 3. Leaf': usterTM Matrix"' 303 Premium Fibered Aluminum Roof Coating, at isq. 4. BusterTM MatrixTM 715, Leak Buster"' MatrixTM 322, TOPCOAT® MB P S, TOPCOAT® FireShield Elastomeric Roofing Membrane, applied at 1 1.5 galJsq. BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./sq. TOPCOAT® Surface Seal, TOPCOAT® FireShield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq. 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes Maximum Design Pressure: -195 psf (See General Limitation #9) NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 34 of 36 Membrane Type: APP & SBS Heat -Weld Deck Type 3: Concrete Decks, Non - Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F(7): Base sheet adhered with approved asphalt. All General and System Limitations shall apply. Base Sheet: One ply of RUBEROID 6 SBS Heat We1dT' Smoo, . torched adhered to primed concrete deck. Ply Sheet: One or more plies of RUBEROID® SBS He r` ' eldTM Smooth or RUBEROID® SBS (Optional) Heat WeldTM 25 torch adhered. Adhered in - 11 mopping of approved asphalt applied within the EVT range and at a of 20-40 lbs. /sq Membrane: One or more plies ply of RUBEROID BS Heat - Weld"' Plus, RUBEROID® SBS Heat- WeIdTM Plus FR, RUBEROID? BS Heat - Weld"' 170 FR, RUBEROID® EnergyCap SBS Heat Weld Plus F RUBEROID® SBS Heat- WeldTM, RUBERO1D® SBS Heat- We1dTM7 : mooth, or RUBEROID® SBS Heat WelddM 25. Applied according to Manufac y 's application instruction. Surfacing: Maximum Design Pressure: -495 psf (See General Limitation #9) (Optional, required over R the following: 1. Gravel or slag applied / ',t 400 lbsJsq. and 300 lbs. /sq. respectively in a flood coat of approved asp t alt at 60 lbs.sq. or applied in a flood coat of Leak Buster"' MatrixTM .! 1 3 Cold Process Adhesive applied at a rate of 3 gal /sq. 2. GAFGLAS® Min :1 Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsh :. adhered in a full mopping of approved asphalt applied within the EVT ge and at a rate of 20-40 Ibs. /sq. ROID® SBS Heat Weld"M Smooth) Install one of 3. Leak Buster atrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gallsq. 4. Leak Bustef Matrix"' 715, Leak Buster"' Matrix"' 322, TOPCOAT® MB PLUS, T.)' COAT® FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 galls 5. Leak B erTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, Ener_ ote® roof coating applied at I to 1.5 gal. /sq. 6. TOP OAT® Surface Seal, TOPCOAT® FireShield® SB SoIvent based El;,'•meric Roofmg Membrane applied at lto 1.5 galfsq. once Green Technologies Photovoltaic Laminate solar energy collector limy roof equipment installed in compliance with manufacturer's ifications and applicable Building Codes 4.10 v1i .72 *J.4"•(•'11 }: IAPPROJED� NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 35 of 36 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 ps£ 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofmg Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 08- 1028.02 Expiration Date: 11/06/13 Approval Date: 02/25/09 Page 36 of 36 TGFU.R1306 - Roofing Systems http: // database .ul.com /cgi - bin /XYV/ template /IiSEXT /1FRAME/showpag... v 9. Deck: C -15/32 Inc line: 1/2 Insulation (Optional): — One or more layers perlite, glass fiber, 3 /4 -in. minimum, polylsocyanurate, urethane, perItte /polylsocyanurate composite, perlite /urethane composite, phenolic, 11/2 In. minimum. Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet ", or "Trl -Ply® #75 Base Sheet ", hot mopped or mechanically fastened In place. Ply Sheet: — One or more piles Type G1 " GAFGIAS® Ply 4" or "TH -Ply® Ply 4" or "GAFGLAS® Ply 6" hot mopped In place. Membrane: — "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR" or "Ruberold® Mop FR" or "Ruberoid® EnergyCapT" Mop FR." Surfadng — (Optional): "GAF Fibered Aluminum Coating" applied at 11/2-gal /100 -ft2 or "GAF Weather Coat Emulsion" applied at 3 -gal /100 -ft2. 10. Deck: C -15/32 Incline: '/2 Insulation (Optional): — Perlite, fiber glass, polylsocyanurate, urethane or perlite/polyisocyanurate composite. Base Sheet: — One or more layers Type G2 "GAFGLAS® #75 Base Sheet" or "TH -Ply® #75 Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "TH -Ply® Mineral Surfaced Cap Sheet" hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type Gi, hot mopped in place. Membrane: — "Ruberold® Mop 170 FR" or "Ruberoid® Dual FR" or "Ruberoid® Mop FR" or "Ruberoid® EnergyCapT"' Mop FR." 11. Deck: C -15/32 Incline: 1/2 insulation (Optional): — Perlite, fiber glass, polylsocyanurate, urethane or perlite/polyisocyanurate composite, butt offset a minimum of 6 -in. from plywood deck joints. Base Sheet: — One or more piles Type G2 "GAFGLAS® #75 Base Sheet" or'TH -Ply® #75 Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "TH -Ply® Mineral Surfaced Cap Sheet" hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type Gl, hot mopped in place. Membrane: — One ply "Ruberoid® Torch Smooth" or "Ruberold® Mop Smooth" or "Ruberold® Mop Smooth 1.5" or "Ruberold® Mop Smooth Plus" or "Ruberold® Dual Smooth." Membrane: — One ply "Ruberold® Mop 170 FR" or "Ruberoid® Dual FR" or "Ruberoid® Mop FR" or "Ruberoid® EnergyCapT"" Mop FR." 12. Deck: NC Incline: 1 Insulation (Optional): — Perlite, fiber glass, wood fiber, polylsocyanurate, urethane or perlite /polylsocyanurate composite. Base Sheet: — One or more layers Type G2 "GAFGLAS® #75 Base Sheet" or "Trl-Ply® #75 Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "TH -Ply® Mineral Surfaced Cap Sheet ", hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type G1 hot mopped in place. Membrane: — One ply "Ruberold® Mop 170 FR" or "Ruberold® Dual FR" or "Ruberoid® Mop FR" or "Ruberold® EnergyCap" Mop FR." 13. Deck: NC Incline: 1/2 Insulation (Optional): — Perlite, fiber glass, wood fiber, poiyisocyanurate, urethane or perite/poiylsocyanurate composite. Base Sheet (Optional): — One or more plies Type G2 or Type G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type Gi hot mopped In place. Membrane: — One ply "Ruberoid® Torch Smooth" (smooth) or "Ruberold® Mop Smooth" or "Ruberold® Mop Smooth 1.5" or "Ruberoid® Mop Smooth Plus" or "Ruberold® Dual Smooth." Membrane: — One ply "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR" or "Ruberoid® Mop FR" or "Ruberold® EnergyCapTM Mop FR." 14. Deck: NC Incline: 1/2 Insulation (Optional): — One or more layers perlite, glass fiber, polylsocyanurate, urethane or perlite /polyisocyanurate composite, any thickness. Base Sheet: — One or more piles Type G1 "GAFGLAS® Ply 4" or "TH -Ply® Ply 4" or "GAFGLAS® Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "T i -Ply® #75 Base Sheet" hot mopped or adhered with Kamak Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 11/2-gal /100 -ft2. Membrane: — One ply "Ruberold® Mop 170 FR" or "Ruberoid® Dual FR" or "Ruberold® Mop FR" or "Ruberoid® EnergyCapT"" Mop FR" hot mopped or adhered with Karnak Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive applied at 11/2-ga1/100 -ft2. 15. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Polylsocyanurate, wood flber, perlite, glass flber any thickness, hot mopped or mechanically fastened. Base Sheet: — One or more plies Type G2 "GAFGLAS® #75 Base Sheet " or "TH -Ply® #75 Base Sheet" hot mopped or mechanically fastened. Membrane: — One or more plies "Ruberold® 30 FR" or "Ruberold® 30 FR HT" or "Ruberold® EnergyCapT"' SBS 30 FR" hot mopped In place. 16. Deck: C -15/32 incline: 1/2 Insulation (Optional): — Polylsocyanurate, wood fiber, perlite, or glass fiber any thickness, hot mopped or mechanically fastened. Base Sheet: — One or more plies Type G2 " GAFGLAS® #75 Base Sheet" or "TH -Ply® #75 Base Sheet" hot mopped or mechanically fastened. Ply Sheet: — One or more piles "Ruberold® 20" or "Ruberold® 20 HT" or "Ruberold® Dual Smooth" hot mopped in place. Membrane: — One or more piles "Ruberold® 30 FR" or "Ruberold® 30 FR HT" or "Ruberold® EnergyCapTr' SBS 30 FR" hot mopped In place. 17. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Fiber glass or perlite, mechanically fastened. Base Sheet: — One or more plies Type G2 hot mopped or mechanically fastened. Ply Sheet: — Two or more piles Type Gi hot mopped or mechanically fastened. Membrane: — "Ruberoid® 30" or "Ruberoid® Modified Cap Sheet 601 ", hot mopped in place. 9 of47 7/19/2012 12:16 PM