CC-11-1036 (3)MANUEL SYNALOVSKI ASSOCIATES November 8, 2011 Miami -Dade County 11805 sw 26th street, suite 150 Miami, Florida 33175 RE: Barry University — Wiegand Center Room 253 Nursing Simulation 11300 N.E. 2"d Avenue FD process number: M2011007923 FIRE 11/01/2011 Comment 9: Response: Comment 10: Response: Part one of comment #3; Please provide door schedule. The minimum door width 2' -10" (32 "clear width). Please also include door #103 in the door schedule. A door schedule has not been provided although all doors being installed as part of the project are labeled with a number and identified in the provided keynotes on sheet A-201. Door #103 is now shown as a 2' -10" door, which is specifically identified in keynote #18. Please for comments #5 (Provide fire class for the movable partition, per U.L. Assembly.) and #6 (Indicate if building has a sprinkler system.); pursue comment #2 first (Provide all info on plans.) A note stating that "the building is not equipped with a fire sprinkler system" has been added to sheet A-201. In addition, keynote 2 has been modified to state "Movable partition with one 36° door from manufacturer to be installed. Refer to sheet A -202 and specifications for more information. This partition is manufactured with all welded steel and class °A° components. It does not carry a fire rating, but is non - combustible." Please contact our office if you have any further questions. Michael Salus Architecture • Planning • Interior Design 1800 Eller Drive, Suite 500 • Fort Lauderdale, FL 33316 • Telephone 954.961.6806 • Facsimile 954.961.6807 MANUEL SYNALOVSKI ASSOCIATES August 19, 2011 Miami -Dade County 11805 sw 26th street, suite 150 Miami, Florida 33175 RE: Barry University - Wiegand Center Room 253 Nursing Simulation 11300 N.E. 2"d Avenue FD process number: M2011007923 ENVIRONMENTAL RESOURCES 7/19/2011 Comment 1: Proposed work involves removal of existing ceiling andn wall as noted in drawing D- 101.... An asbestos survey is required.... Response: The space is currently underway with the required asbestos abatement. Proper paper work will be filed and abatement will be completed prior to commencement of work. STRUCTURAL 8/1/2011 Comment 1: Response: Comment 2: Response: Comment 3: Response: Provide written response to comments. Refer to the provided comment response. Provide all info on plans. All comments have been addressed and the necessary revisions to the drawings have been completed. Provide the door schedule, door 101 must be rated 3/4 hour rated and have closer. Keynote 13 on sheet D -101 and keynote 20 on sheet A-201 have both been revised to call out for a rated door with a closer to be installed in door location 101. All associated partitions are now scheduled to be rated and fire dampers are scheduled to be installed. Architecture • Planning • Interior Design 1800 Eller Drive, Suite 500 • Fort Lauderdale, FL 33316 • Telephone 954.961.6806 • Facsimile 954.961.6807 Comment 4: Response: Comment 5: Response: Comment 6: Response: Comment 7: Response: Page 2 SHT A -201, GA is not referenced in the FFPC. Provide UL assembly for fire rated partition. The detail referencing °GA° has been removed and replaced with U419 (UL 263) now shown on 5/A -202. Provide fire class for the movable partition, per U.L. Assembly. The partition is manufactured with all welded steel and all Class °A° components. It is not a UL fire rated wall (does not carry a 1 hr Fire rating but is non - combustible). Indicate if building has a sprinkler system, If so then provide the location and relocation of heads. This building is not equipped with a fire sprinkler system. Resubmit. All drawings have now been resubmitted with this comment response document. Please contact our office if you have any further questions. MANUEL SYNALOVSKI ASSOCIATES July 7, 2011 Miami Shores Village Building Department 10050 N.E. 2'd Avenue Miami Shores, Florida 33138 RE: Barry University - Wiegand Center Room 253 Nursing Simulation 11300 N.E. 2'd Avenue Parcel ID: 1223 -11 -0011 Permit No: 11 -1036 Building Critique Sheet 7/05/11 Comment 1: Response: Comment 2: Response: Comment 3: Response: Comment 4: Response: 0 Plans must be approved by Miami Dade County Fire. General contractor will assist with expediting the approval process. Plans must be approved by Miami Dade DERM. General contractor will assist with expediting the approval process. All permit applications must be submitted prior to any further review. General contractor will provide all necessary information for future reviews. Provide a floor plan showing the egress to the exterior of the building. Refer To detail 9/A-201 for provided existing floor plan showing egress route from scope of work to a protected stair enclosure leading to the exterior of the building. Architecture • Planning • Interior Design 1800 Eller Drive, Suite 500 • Fort Lauderdale, FL 33316 • Telephone 954.961.6806 • Facsimile 954.961.6807 1 r Page 2 Comment 5: Provide the fire classification for the finishes on the folding wall. Response: The panels themselves are steel (primed steel skins) with all non - combustible materials. The fabric finish to cover the steel panels will be selected by the owner as the project moves forward. Notation listed in the "General Notes" identifies that the flame spread classification for all interior finishes shall comply with FBC Table 803.5 and NFPA Table A10.22.2.. Comment 6: Provide a detail of the retractable track at the door to show compliance. Response: A dimension has been added to detail 4/A-301 showing that the required 12" of clear space on the push side of the door has been provided. Please contact our office if you have any further questions. Thank y Mic ael ..Ius Pro ect Manager