Loading...
MC-12-1846Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 181010 Permit Number: MC -10 -12 -1846 Scheduled Inspection Date: October 31, 2012 Inspector: Perez, JanPierre Owner: CORTES, MARIA Job Address: 1562 NE 105 Street Miami Shores, FL 33138 -0000 Project: <NONE> Contractor: SEER AIR CONDITIONING Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number (305)458 -9935 Parcel Number 1122300530130 Phone: 305 -552 -9810 Building Department Comments CHANGE OUT 3 TON SPLIT SYSTEM Infractlo Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP - 179448. remove wood from under c/u October 30, 2012 For Inspections please call: (305)762 -4949 Page 42 of 44 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 [P Permit No. Master Permit No. � I y� M 'A( Permit Type: MECHANICAL o.,, ok ,� �° ylc u rH e s OWNER: Name (Fee Simple Titleholder): 14 P Z (JQU V cat/uo lrc. LL-C, Phone #: 7r6 9 n n3 Address: /562_, VC- 1 ,0c 5 4 r4 (+- City: d S Vtil ire S State: 'f Zip: 351 Tenant/Lessee Name: "-- Phone#: 7U 4 ? M Email: �",<CJGroUPIY%4:) jo1k'o JOB ADDRESS: /;c6 Z VG., Ey 4rf - O City: Miami Shores County: f r Miami Dade Zip: 7D' Folio/Parcel #: Q k LL 300 S 30 3 0 Is the Building Historically Designated: Yes NO Flood Zone: i CONTRACTOR: Company Name: „Sees,- 4A/ (6.1 Eon/ % j Phone f )JJ —1» / Address: C/ 0 S r' 1'1 4,@,_ City: 15. State: (a) ►�1 Zip: ��/ Qualifier Name: s� v �� �� �fE�' Phone /006 -34- / State Certification or R,gistration #: CH- c- (de/ 33 OJ Certificate pcCompetency #: Contact Phonel 10 )`jet I — Z) _/ Email Address: s e -`4or- atu„ DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ �' � Square/Linear Fooe of Work: Type of Work: °Address °Alteration °New f�'Repair/Replace °Demolition Description of Work: i 0.-c f Th: it & titNi ******** * * * * * * * * * * * * * * * ** *** ** * **l *' *** *F ix ( ********* x ***** ****** * * * * ** ** ***** *�x�xa� **** Submittal Fee $ C3 Permit Fee $ I(® `' V CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for Fi.FCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of conunencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature a Owner or Agen The foregoing instrument was acknowledged before me this, day of ,20j , by who is personally known the or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commi sEXPIRES December 06 2013 (407)1398 -0153 Fl oridaNatarySernce.com Signature Contractor The foregoing instrument was acknowledged before me this day of 01f64/1 , 20 l2, by v&'Mn 'fit'" a- , who is personally known to who has produced as identification and who did take an oath. NOTARY zuBLIC: Sign Prir My tML MISSION # DD944554 ;',F;, EXPIRES December 06 2013 (407) 398 -0153 FloridalloteryService.00m + Il+ k*+ k, klk+ k, krk, kd' I+ N+ h*****M rN, bIR, kN1 ****rk+kNl,k,llNr,),+kgrlN*** + *** Iklk�kdl+ MrRIk, I1****, kIMINR�k IPK11Ntl1, R, k, k#Iklk,kB�klkgllk+k*** *tkBlkdr, it ,k+k+NrM,kd�Ik,k,N,kB+kAl***** APPROVED BY 1� Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. �— Job Address (where the work is being done): 14, 2_ ede — / an /tee et Zip Code: 33 1 City: Miami Shores Village County: Miami Dade ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI HRI) DATA SHEET REQUIRED ARHI Sheet Attached: YES NO Change Disconnecting means: YES ❑ NO ❑ Contract Attached: YES 13/ UNIT BEING REPLACED DATA NEW UNIT (�-QO�m.5� A eotFef2Ct f h ,e.C, MANUFACTURER Pr�4 �a4. Cf AHU or PKG. UNIT MODEL# PIA- 4-091-)4:2- COND. UNIT MODEL # -S )C 00 tt,� 1 '4-Kw KW HEAT 1-44u) 'i 1-4%.1 NOM TONS 'S > 3^e`,✓ S AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / titiKnoia mein -AML /.44,+-uh EERISEER 1 °3 YES NO REPLACING DUCTS YES CIO YES NO REPLACING THERMOSTAT jf'E$1 NO YES NO NEW 4 °CONCRETE SLAB S lay` YES NO NEW ROOF STAND YES ► e YES NO NEW RETURN PLENUM BOX YES 69 . 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker Size): MI iii t D j C4.1401`v') c LA +0 4.1 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: t .,c0 Contractor's Company Name: State Certificate or Regis, _ ' • , N. CAC- (/ I 's`k, u J Certificate of Competency N. d4) Signature Qualifier's signature only) SEER AIR CONDITIONING CORP. COMERCIAL & RESIDENCIAL Installations • Sales • Services 100% FINANCING Lic. # CAC1813305 9 2 1/1 Date:' r fir, Customer Name:df% u _ " 61V6/A("il ) Years at Current Location: CustomerAddressb i /of Alyce _P Telephone No.: City, State and Zip Code: R, Fax/Mobile NO 7.4.7 Social Security No.: Date of Birth: Name of Property Owner (If different from Customer): Address of Property Owner (if different from Customer): City, State and Zip Code of Property Owner (If different from Customer): Relationship of Customer to Property Owner (If Property Owner is different from Customer): SYSTEM EQUIPMENT AND TYPE OF MATERIAL USED: 1'' s e (` % i.'t.'f "mss t w I415 14a c' .rb 4/Z1 -' F C ! L' u t �/ r -i / ,mo t - ci„.9-Y. i___Ii `Al if Le( A 1 cc— (...., —14, —I-4c ti.,,,, - '''K' 1 ' ' ' ' ,I C mss ' ! i ` P r �J e r ? (-. '``r 0 1 j r -7 -, UNIT: 1, 74,, SUPPLIES: SEER: / ee 44, `Job Price $ - �. ; /(1--)1' Tax $ Rebate $ Job Total $- � E- INSTALLATION SCHEDULE We will be ready to begin installetjo?"- approxirttetely a by: 1 � �: ;:ry Seller Approval: Salesperson: t (9 ._ b Purchaser Acceptance: Contract () Date: s � �Cpirati9n Date: Installation Date.y ° if re Phon h1 1 f •KITCHEN: • DINING ROAM ® RETURN ■BATHROOM • FLORIDA -ROOM a E WATER PUMP ■ LIVING ROOM • BEDROOM • ADDITION • FAMILY ROOM • DEN • INSTALLATION SCHEDULE We will be ready to begin installetjo?"- approxirttetely a by: 1 � �: ;:ry Seller Approval: Salesperson: t (9 ._ b Purchaser Acceptance: Contract () Date: s � �Cpirati9n Date: Installation Date.y ° if re Phon h1 1 f 1/2 IN THE EVENT OF MATERIALS BREACH In the event that either party commits a material breach of any term of this Agreement, the other party chall have the right immediately to terminate this Agreement. Not failure on the part of either party to exercise or delay in exercising, any right under this Agreement shall operate as a waiver of such right, nor shall any single or partial exercise of any right preclude any other or further exercise of any right under this Agreement. The remedies provided in this Agreement are cumulative and are not exclusive of any other reme- dies provided by law. MODIFICATION ON THIS AGREEMENT NO modification to this Agreement shall be enforceable, unless in writing and signed by both parties. INTEGRATION CLAUSE There are no other Agreement between the parties, either written or oral, regarding the subJect matter contained herein and this Agreement reflects the full and complete under- standing between the parties. FORCE MAJEURE Delay caused by floods, strikes, labor disputes, accidents, Acts of God or any other cause beyond the reasonable control of the Contractor shall excuses or extend the time for per- formance of the contract, as based upon the reasonable assessment, evaluation and opinion of the Contractor. Customer warrants that Customer carries an adequate amount of casu- alty, property and general liability insurance to insure and protect against any damages caused or occasioned by any delay caused by floods, strikes, labor disputes, accidents, Acts of God or any other cause beyond the reasonable control of the Contractor. LIABILITY FOR DAMAGE TO PROPERTY The Contractor will not be held liable for any damages to the property that may occur during or after installation, or during the servicing of air conditioning unit or any equipment, including all items within the home regardless of fault. All damages are sole responsibility of the property owner, financially and otherwise. Any water leaks, penetration of water through roof, floors or walls of clients property must be repaired by a licensed plumber, roofer, etc., at their (clients) expenses. Customer shall assume any and all liability for damages caused to real and personal property through the Customer's failure to keep the area demised for the sale, delivery and installation of heating, ventilation, refrigeration and air conditioning equipment, parts, supplies and related (HVRAC) materials nd area demised for professional consultation, eval- uation, fitting, installation, repair and replacement services performed free and clear of impediments, obstacle and obstructions that may hinder or prevent the Contractor from the discharge of its duties. Customer expressly assumes liability for any and all damage of any kind, and caused by any party, to valuable objects or effects found and located in the area demised for work. • ; 1010. , ; t ;_01111 dl 1 y_ ;_lu1 THE ONLY GUARANTEES OR WARRANTIES PROVIDED FOR MATERIALS AND RELATED CONSTRUCTION PRODUCTS AND SUPPLIES FURNISHED OR INSTALLED BY THE CONTRACTOR ARE THOSE PROVIDED BY THE MANUFACTURERS, DISTRIBUTORS AND THIRD PARTIES OTHER THAN THE CONTRACTOR. CONTRACTOR MAY, AT ITS SOLE DISCRETION, O1F1-EE4 THE CUSTOMER AN ADDITIONAL WARRANTY OVER AND ABOVE THE WARRANTY OR WARRANTIES, IF ANY, PROVIDED BY THE MANUFACTURERS, DISTRIBUTORS AND THIRD PARTIES OTHER THAN THE CONTRACTOR. IN THE INSTANCE THAT THE CONTRAC- TOR OFFERS AN ADDITIONAL WARRANTY TO THE CUSTOMER, ANY SUCH WARRANTY SHALL BE EXPLICITLY STATED IN WRITING BEFORE THE COM- MENCEMENT OF ANY WORK. ANY WARRANTY THAT THE CONTRACTOR PROVIDES TO THE CUSTOMER, WHETHER FOR PARTS, LABOR OR BOTH, SHALL NOT INCLUDED MANUFACTURER RECOMMENDED OR ROUTINE CARE AND MAINTENANCE, WHICH REMAINS THE RESPONSIBILITY OF THE CUSTOMER; OR REPAIR OR REPLACEMENT ARIS- ING FROM DAMAGE CAUSED BY ABUSE, MISUSE OR INTENTIONAL OR NEGLIGENT ACTS AND OMISSIONS PERFORMED BY THE CUSTOMER OR ANY THIRD PARTY AND /OR DAMAGE CAUSED BY MALFUNCTIONING ELECTRICAL SYSTEMS OR POWER SPIKES OR SURGE. AFTER THE COMPLETION OF THE WORK, ANY CALLS TO THE CONTRACTOR REGARDING MATTERS OUTSIDE THE SCOPE OF THE WARRANTY PROVIDED SHALL BE BILLED AT THE CONTRACTOR'S STANDARD HOURLY RATE. CONTRACTOR HEREBY DISCLAIMS ALL WARRANTIES OF ANY KIND OR NATURE WHATSOEVER- PERTAINING TO THE SALE, DELIVERY AND INSTALLATION OF HEATING, VENTILATION, REFRIGERATION AND AIR CONDITIONING EQUIPMENT, PARTS, SUPPLIES OR RELATED (HVRAC) MATERIALS AND /OR PERTAINING TO THE PROFESSIONAL CONSULTATION, EVALUATION, FITTING, INSTALLATION, REPAIR AND REPLACEMENT SERVICES PERFORMED (INCLUDING WARRANTIES OF MERCHANTABILITY OR HABITABILITY AND FITNESS FOR PARTICULAR PURPOSES), WHETHER EXPRESSED OR IMPLIED UNLESS EXTENDED, GRANTED OR MODIFIED, IN WRITING. LIMFFATION OF REMEDIES CONTRACTOR SHALL NOT BE RESPONSIBLE FOR ANY CONSEQUENTLALDAMAGES ARISING BECAUSE OF THE FAILURE OR MISUSE OF ANY PRODUCT CONTRAC- TOR IS NOT RESPONSIBLE FOR MOVING OR REINSTALLING MAJOR APPLIANCES OR CUTTING DOOR. ALL MATERIALS AND RELATED CONSTRUCTION PRODUCTS AND SUPPLIES SHALL BE WARRANTED SOLELY BY THE MANUFACTURERS, DISTRIBUTORS AND THIRD PARTIES OTTER THAN THE CONTRACTOR THAT PROVIDE SUCH GUARANTEES AND WARRANTIES TO CONSUMER AND END- USERS. IN THE EVENTTHAT THE CONTRACTOR OFFER A WARRANTY TO THE CUSTOMER, CONTRACTOR RETAINS SOLE AND EXCLUSIVE DISCRETION REGARDING THE MANNER OF HONORING THE WARRANTY INCLUDING BUT NOT LIMITED TO THE SELECTION OF REPLACEMENT PARTS, THE METHOD OF REPAIR AND /OR REPLACEMENT AND ALL RELATED ISSUES AND SURROUNDING THE MANNER IN WHICH THE WARRANTY IS FULFILLED. TITLE Legal and equitable title to all heating, ventilation, refrigeration and air conditioning equipment, parts, supplies and related (HVRAC) materials sold, delivered, installed, repaired and/or replaced under this Agreement remain vested in the Contractor unless and until the Customer has paid the Contractors in full for all materials sold and work performed. www.sunbiz.org - Department of State FLORIDA DEPARTMENT OF STATE DIVISION OF CORPORATIONS .SNnhhZ Home Page l of 2 Contact Us E- Filing Services Document Searches Forms Help Previous on List Next on List Return To List Entity Name Search No Events No Name History j Submit j Detail by Entity Name Florida Limited Liability Company HARBOUR SHORES LLC Filing Information Document Number L12000049973 FEI/EIN Number NONE Date Filed 04/1212012 State FL Status ACTIVE Effective Date 04 /12/2012 Principal Address 785 CRANDON BLVD. SUITE 306 KEY BISCAYNE FL 33149 Mailing Address 785 CRANDON BLVD. SUITE 306 KEY BISCAYNE FL 33149 Registered Agent Name & Address GOMEZ, DIEGO G 785 CRANDON BLVD. SUITE 306 KEY BISCAYNE FL 33149 US Manager /Member Detail Name & Address Title MGR GOMEZ, DIEGO G 785 CRANDON BLVD. SUITE 306 KEY BISCAYNE FL 33149 Title MGR CORTES, MARIA C 785 CRANDON BLVD. SUITE 306 KEY BISCAYNE FL 33149 Annual Reports No Annual Reports Filed Document Images http:// www .sunbiz.org/scripts /cordet.exe ?action= DETFIL&inq_doc number= L120000499... 7/26/2012 www.sunbiz.org - Department of State 04/12/2012 — Florida Limited Liability f View image in PDF fonnat _ Note: This is not official record. See documents if question or conflict. Previous on List Next on List Return To List No Events No Name History Page 2 of 2 Entity Name Search [Submit i 1 Home 1 Contact us 1 Document Searches 1 E-Filinq Services 1 Forms 1 Help 1 Copyriqht © and Privacy Policies State of Florida, Department of State http://www.sunbiz.org/scripts/cordet.exe?action=DETFIL8cinq_doc_number=L120000499... 7/26/2012 ..1 CERTIFIE 1,1 tn4J ahlidirectary or Certificate of Product Ratings AHRI Certified Reference Number: 5360116 Date: 10/3/2012 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130421B* Indoor Unit Model Number: ARUF42C14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI - sponsored, Independent, third party testing: Cooling Capacity (Btuh): 39500 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 * Ratings followed by an asterisk (1 Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which is listed below. © 2012 Air - Conditioning, Heating, and Refrigeration Institute Air- Conditioning, Heating, I■� �' and Refrigeration Institute CERTIFICATE NO.: 129937691073283277 Street Address ■ ud DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Location: 1562 NE 105 Miami, FL 33138 • 25,7791i House Square Footage: 1726 sq. FL. Maria Carina Cortes Phone: 786-463-7531 Email: seerair@aol.com SHR Nbr of' LeSi dehts .75 Ceiling height 9 Wali R-value L09 1 11 Floor Li-value R-value 0.2 I 5 Lie I Pi-value 005 I 1,2 Window U-value 0.5 Moisture grains 58 Duct loss % 10 Duct gain % 10 Cooling iniiiitraction (ACH) Heating infiltration (ACH) 0.8 • Winter ventilation Summer ventilation 0 Desiell Conditions Outdoor Daily range Heating Cooling 90 Relative ilLimiclity 0% Moisture difference 58 Indoor Heating Cooling Indoor temperature (aF) 70 75 Design temperature difference(°F) 20 15 Heati n• Loads Area Wall Floor CeiGinr Windows •Fi I t•H Btuh % of Toad 1672 10.4 4356 27.1 1832 2490 15.5 4243 26<4 System Efficiency Loss 1459 9.1 Total: • 16051 Floor Heating Loads 16.051 BTU /hr Infiltration System Efficiency Loss / r WaII Ceiling - ® `- Windows Area Latent ins itra :io i Interiiat Latent Pecip e Load 795 Btuh % of load 1,254. 2 170P 5 704 193 Latent load 61A9 f_apac ry at .75 SHR 3.63 Tons 4.9 Windows Cooling Loads 39,198 BTU /hr ( Sensible People Load Latent People Load !!! Wall !'-- Ceiling Internal Sensible Infiltration? System Efficient; `- Latent Infiltration AED Graph 40000 0 ...._.__._.. Sam gam 10am clam 12pm 1pm 2pm 3pm 4pm Spm 6pm 7pm 8pm — Hourly Loads — Average ACCA Manual S System equipment selection will be made using the following Manual 5 derived values. Summer Outdoor Summer Indoor Summer Design Grains Winter Outdoor Winter lridoor Sensible Cooling Latent Cooling Required Cooling Airflow Sensible Heating Required Heaing Airflow 90 °F 75 °F 50 °F 32,699 Btuh 1,486 CFM 16,051 Btuh 208 CFM AO calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree