Loading...
RF-12-962Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 178687 Permit Number: RF -5 -12 -962 Scheduled Inspection Date: November 19, 2012 Inspector: Bruhn, Norman Owner: AKERMAN, SANDRA Job Address: 1170 NE 100 Street Miami Shores, FL 33138- Project: <NONE> Contractor: QUALITY ROOFING CONTRACTORS INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1132050190400 Phone: (305)953 -3333 Building Department Comments REPLACE VENT AND REPAIR FLASHING OF FLAT ROOF. Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 174126. BY MARY November 16, 2012 For Inspections please call: (305)762 -4949 Page 12 of 29 Miami Shores Village RECEIVED Building Department MAY 2 5 MI 90050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 i2 -'ICI BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 1 170 N. E. 100 S t r e e t ai rub FBC 2010 Permit No. ?.F-'I2--9(2.-- Master Permit No. City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel #: 1 1 — 3205-01 9 -0400 Is the Building Historically Designated: Yes NO X Flood Zone: OWNER: Name (Fee Simple Titleholder): Sandra Akerman Phone#: (305) 528-4820 Address: 1 1 7 0 N.E. 100 S t r e e t City: Miami Shores state: Florida Zip: 33138 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name:Quality Roofing Contractor, Inc.Phone#: ( 305) 953 -3333 Address: 13800 N.W. 1st Avenue City: Miami State: Fl Zip: 33168 Qualifier Name: Carlos Arocho Phone#: ( 786) 367 -2029 State Certification or Registration #: RC 0058627 Certificate of Competency #: 0 0 0 017889 Contact Phone#: (305) 953 -3333 Email Address: quailtyroofina88 @vahoo.com DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 900.00 Square/Linear Footage of Work: 1 / 2 s q . Type of Work: DAddition DAlteration New X0tepair/Replace ODemolition Description of Work: Replace vent and repair flashing of flat roof . Color thru tile: m ******** **** ****** * ***v***********x *** Fees**** ****** ** ***** ** **+x** ******* * ********* * ** aa Submittal Fee $ Permit Fee $ /e0 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ " -(0 Bondh cofnpany's-Nan a (if applicable) BondIng Company's, Address' City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT.FCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature (�� R_ . Signature Contractor The foregoing instrument was acknowledged before me this c2 2 day of Ro , 20I X , by S who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: . Of ORIDA My Commission Expiz e Marylou H ` andez r ;Commission #DD930046 -,, ssi Expires: OCT. 10, 2013 BONDED THRU ATLANTIC BONDD G CO., INC. The foregoing instrument was acknowledged before me this day of .e , 201 , by &less ch._o , who is personall own to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: r AgEW My Commission Expo = a Marylou He andez Commission #DD930046 Expires: OCT. 10, 2013 BONDED THRU ATLANTIC BONDING CO., INC. **************** ***************** ******* #****** k+1 ************* #** #***** ******** ********pia*************** #**** APPROVED BY Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Zoning Clerk • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES . , RECEIVED MAY 2 5 2011 Florida Building Code Edition 2010 _ _11041- High-Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractor's Name Quality Roofing Contractor, Inc . Job Address 1170 N.E. 100 Street ❑ Low Slope ❑ Asphaltic Shingles ❑ New Roof ❑ Reroofing Low Slope Roof Area (SF) ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Metal Panel/Shingies ❑ Wood Shingles/Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ Recovering DI Repair ❑ Maintenance ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) Section B (Roof Plan) Total (SF) 1 / 2 sq. Sketch Roof Plan: Illustrate all levels and sections roof drains, scu , pper* overflow scitgm w ins. F. g� Include dimensions of sections and levels, clearly identify dimensions o . parapets. APPROVED BY DATE 15.34 ZONING DEPT BLDG DEPT MP CE l .ITH ALL FED _HAL NT`s RULES ANf) TIONS „k. Jr) v 2010 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Existing Roof Roof System Manufacturer: Santa Fe Tile Corporation Notice of Acceptance Number: 10-1005.15 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): . N/A N/A N/A P N P2: P3: Roof Slope: 3 : 12 Steep Sloped Roof System Description Deck Type: wood 1 X 6 Type Underlayment: Ridge Ventilation? N/A Insulation: 301b. N/A Fire Barrier: Mean Roof Height: 13' N/A Fastener Type & Spacing: Adhesive Type: 1 1/4" R/S nails Type 111 mopping asphalt Type Cap Sheet: 901b. Roof Covering: Spanisb€8 C1iw Tile Type & Size Drip Edge: 3 X 3 26ga. galv. 15.36 2010 FLORIDA BUILDING CODE — BUILDING MIAMNQADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Santafe Tile Corporation 8825 NW 95th Street Medley, FL 33178 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/huildine/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Section and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and /or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 07- 0626.03 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.: 10-1005.15 Expiration Date: 02/01/16 Approval Date: 01/06/11 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Sub-Category: Material: Deck Type: Roofing Rooting Tiles Clay Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Santafe Tile Corporation in Bogota, Colombia and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Product Description Santaf4 `S' Clay L = 18" TAS 112 One piece high profile clay roof tile equipped Roof Tile W = 11.1" with two nail holes. For nail -on, mortar set and adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, clay roof pieces for use at w = varies hips, rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. 2.1 SUBMITTED EVIDENCE Test Agency Test Identifier The Center for Applied Engineering, Inc. 94 -156 -8 94 -156 -9 The Center for Applied Engineering, Inc. 25- 7205 -1 The Center for Applied Engineering, Inc. Project 07- 07 -00 -91 (307023) Redland Technologies Redland Technologies 7161 -03 Appendix 1I 7161 -03 Appendix III Test Name/Report Date TAS 101 Aug. 1994 TAS 102 TAS 101 March 1995 TAS 100 Sept. 1994 TAS 108 Dec. 1991 (Nail -On) Static Uplift Testing Dec. 1991 TAS 102 & TAS 102(A) NOA No.: 10- 1005.15 Expiration Date: 02/01/16 Approval Date: 01/06/11 Page 2 of 5 Test Agency Redland Technologies Redland Technologies Redland Technologies Celotex Corporation Testing Services IBA Consultants, Inc. PRI Asphalt Technologies, Inc. IBA Consultants, Inc. IBA Consultants, Inc. IBA Consultants, Inc. Test Identifier P 0402 P 0647 -01 P 0631 -01 520305 -01 thru 05 2353 -4 SFTC- 003 -02 -01 2353 -70 2353 -71 2353 -93 Test Name/Reeort Date Withdrawal Resistance Testing of Screw vs smooth shank nails TAS 108 (Mortar Set) PA 108 (Mortar Set) PA 102 Sept. 1993 Aug. 1994 July. 1994 June 1999 Restoring Moment Aug. 1999 TAS 101 12/06/02 TAS 101 09/22/03 TAS 101 09/22/03 ASTM C 1167 07/18/05 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 32 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (Ibf) Length -I (ft) Width w (ft) Santafe 'S' 6.7 1.5 0.958 NOA No.: 10-1005.15 Expiration Date: 02 /01/16 Approval Date: 01/06/11 Page 3 of 5 Table 3: Restoring Moments due to Gravity - Ma (ft -Ibf) Tile Profile Table 2: Aerodynamic Multiplyers- X ft3 4 " :12" Tile 6 ":12" X (ft3) X (ft3) Battens Profile Battens Batten Application Direct Deck Santafe 'S' Battens Direct Deck 0.274 0.297 Table 3: Restoring Moments due to Gravity - Ma (ft -Ibf) Tile Profile 2 ":12" 3 ":12" 4 " :12" 5 ":12" 6 ":12" 7 ":12" greater Battens or Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Santafe 'S' 5.93 5.90 5.85 5.82 5.73 5.69 5.56 5.53 5.32 5.29 5.03 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck Battens Santafe 'S' 2 -10d Ring Shank Nails 21.8 N/A One #8 Screw 29.16•2 N/A Two #8 Screws 38.28' N/A One #8 Screw w/ Clip 57.311' N/A Two #8 Screws w/ Clip 57.60' 61.77' 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Ni, (ft -Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Tile Bond 38.9' Polyfoam Polypro AH 1607"' 28.54 2 See manufactures component approval for Installation requirements. 3 Flexible Product, Inc. Average weight per patty 10.4 grams. 4 Polyfoam Product, Inc. Average weight per patty 9.4 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Polyfoam Polypro AH 160 TN° 63.8° Polyfoam Polypro AH I6OTM 61.9" 5 Paddy placement of 63 grams of Polypro AH 160To. 6 Paddy placement of 24 grams of Polypro AH 160TH". NOA No.: 10- 1005.15 Expiration Date: 02/01/16 Approval Date: 01/06/11 Page 4 of 5 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Santafe 'S' Mortar Set 23.6 NOA No.: 10- 1005.15 Expiration Date: 02/01/16 Approval Date: 01/06/11 Page 4 of 5 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved ". SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. 18" PROFILE DRAWING When using one screw use this hole. 11.1" "SANTAFI S" CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 10- 1005.15 Expiration Date: 02 /01/16 Approval Date: 01/06/11 Page 5 of 5 SECTION 4402 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 44 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics- Workmanship: The workmanship provisions of Chapter 44, Section 4402 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renalling Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403 (High Velocity Hurricane Zones) of the Florriid, da Building Code. (The roof deck is usually concealed prior to removing the existing roof system.) >> 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. 5. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Sections 4402, 4403 and 4413. 9'4)1 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. s- 1,? -I la\ Owner's /Agent's ignature Date \\" 0 MG— \oOS Permit Number Property Address Contractor's Signature