RF-12-1092Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 174828 Permit Number: RF -6 -12 -1092 Scheduled Inspection Date: October 10, 2012 Inspector: Bruhn, Norman Owner: BLANCO, FRANK Job Address: 9535 BISCAYNE Boulevard Miami Shores, FL 33138- Project <NONE> Contractor: MIAMI ROOFING SYSTEMS INC Permit Type: Roof Inspection Type: Final R ?of Work Classification: Tile Phone Number (786)251 -1500 Parcel Number 1132060143050 Building Department Comments RE ROOF TILE Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. October 09, 2012 For Inspections please call: (305)762 -4949 Page 12 of 46 Lab Report No. 120744 FLORIDA TEC Providing Solutions to the Roofing Industry C.A. #: 26095 Lab Certificate: 09- 0715.02 CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106 PROPERTY ADDRESS.: 9535 Biscayne Blvd. Miami PERMIT No: RF6 -12 -1092 ROOFING SQUARES: 39 ROOF PITCH :: 3:12 INSPECTOR INITIALS: AB TEST DATE: 10/2/2012 OWNER: Frank Blanco CONTRACTOR: Miami Roofing TILE TYPE: Flat ATTACHMENT:: Polyfoam Testing Equipment: Digital Chatillon DFIS 200 Test Tabulation Required Testing Force: 35 Ibs No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT 1 -9 Passed 40-49 Passed 10 -19 Passed 50 -59 Passed 20 -29 Passed 30 -39 Passed THIS ROOF HAS: PASSED FAILED ❑ THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI -DADE COUNTY TAS 106. Reviewed by: Alberto Cardona, P.E. -Lic #17138 10735 SW 216t1 St. Unit 416 Miami, FL 33170 Frond www.floridatec.net Tel: (305) 256 -4550 Fax (305) 256 -6833 Miami Shores Vivage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # RF' CO— 1 a - i o c1 a DATE: "� lob 1)g- INSPECTION AFFIDAVIT 1 ..-SQV I e 1, R ! 'AQ (-h a licensed as a (n)ontracW4 Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: On or about 7 blia )o, (tgiv , I did personally inspect the roof deck nailing and (Date & time) (� secondary water barrier work at ��5 �J«CCuyYI� (Complete Job Site Address) Based upon that examination I have determined the installatioi was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) gnature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn and subscribed before - this nnci day of -3v11 ool a 1 Notary Public, Sate of Florida at Large `General, Building, Residential, or Roofing Contractors or any indM address # dearly shown marked on the deck for each inspection Revised on 512112009 dude photographs of each plane of the roof with pennft # and Miami Shores Village Building Department 1@050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 9335 BISCAYNE BLVD ECM E SEP 2 0 ?C12 FBC 20 Permit No. RF -6 -12 -1092 Master Permit No. ROOFING City: Miami Shores . County: Miami Dade Zip: Folio/Parcel #: 11- 3206 - 014 -3050 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): FRANK BLANCO Address: 9335 BISCAYNE BLVD Phone #: 786 521 -4443 City: MIAMI SHORES Tenant/Lessee Name: Email: State: FL Zip: 33138 Phone #: CONTRACTOR: Company Name: MIAMI ROOFING SYSTEMS,INC Address: 667 NW 101 ST City: MIAMI Qualifier Name: JAVIER R MARTINEZ Phone #: 3057545554 State: FL Zip: 33150 Phone #: State Certification or Registration #: Certificate of Competency #: Contact Phone #: 3057545554 Email Address: MIAMIROOFINGSYSTEMS @YAHOO.COM DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ v Square/Linear Footage of Work: Type of Work: ❑Addition DAlteration ❑New Description of Work: REVISED FRONT SECTION TO POLYG ORepair/Replace ODemolition Color thru tile: ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *** g******************************************** Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ 41.00— Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will t be approved a reinspection fee will be charged. Signature Owner or Agent The foregoing pstrument was cknowledged before me this day of _, 20/2 -, by js/� Ql4h `v T ersonall Signature x Contractor 97'1 The foregoing instrument was acknowledged before me this , day of —1 f 20 I -, by s7el‘4,"e 0 S2' 1f AV tilK, o has produced As identification and who did take an oath. NOTARY PUBLIC: iTiliiiiii • ills" • Ii!r /•rte as produced s identification and who did take an oath. NOTARY PUBLIC: My!om n Ex s ire * ***:xx: ******+x: **** ** * *** *******+x*********** ** x**************m **********x:********** : ****+x *x:********* ****** *** APPROVED BY ' ?% V i R'1 Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Zoning Clerk ROOF ASSLiMBUES AND ROOFTOP STRUCTURES RECEIVE SEP 2`701Z Master Permit No Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform PernhItApplieatfot- -F .— Y DAIL . _ :A:SCE 'si! FN ALL FEDERAL Process No. Contractor's Name iQn 00T VA Ck Job Address "'i�35 t�1 C',C9nt= 6 \\A ❑ Low Slope ❑ Asphaltic Shingles ❑ New Roof ❑ Mechanically Fastened Tile ❑ Metal PaneUShingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ MortarlAdhesi met Tile ❑ Wood Shingl /Shakes' XReroofing ❑ Recovering ❑ Repair ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 3 Section B (Roof Plan) Total (SF) 3945 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. A 1 Ian , IP 11411 41/01% 'IiibAhk I no 10 �o 0 FLORIDA BUILDING CODE ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 15.36 Florida Building Code Edition 2010 High- Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: Eq34 i Notice of Acceptance Number: la-0430.0V Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): a P1: ler. • P2: a P3: — s-i. [ieVentllation? Steep Sloped Roof System Description Deck Type: Type Underlayment: Insulation: sIE Lean Roof Height: t a' Be) i9sY-iti Fire Barrier: Fastener Type & Spacing: Adhesive Type: I— Type Cap Sheet: ply 2� 1 Se_14 44041-ed ty,.56a7uFij Roof Covering: �.. 7; ( Type & Size Drip Edge: r3)13dh 2(o GA 2010 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High- Velocity Hurricane Zone Unlfomi Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mr values UM greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. OG Method 1 "Moment Based The Calcula ons Per RAS 127" ,,��/j�� Q (Pt '•e Z '_• "t.Mg :'•G7 =Mrt`_• G5 Product Approval Mft.a /• a (P2• -Sb• x ' 7 _/3• )-M$ `7 =MaC 3ss Product ApprovalMf5104 CI (P3 'SIN° k •ei� _, • ) Mg: • o7 = Mr3 W 4J Product Approve) Mr,C• (J Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval M f Mr required Moment Resistance* Mean Roof Height ^> Roof Slope 1, 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6;12 20.4 28.0 29,4 30.5 32.4 7:12 24.4 26.9 27.1 28.2 30.0 "Must be used in conjunction with a list of moment based die systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Pr. If the F' values are greater than or equal to the Err values, for each area of the roof, than the tile attachment method is acceptable. Method 3 "Uplift Based The Calculations Per RAS 127" (Pt: x L = , x w: _ ) - W: , x cos 0 = Frl Product Approval F' (P2 x L - x w: _ ) - W. x cos 8 = Pri Product Approval R' (P3' x L , x w: = ) - W: x cos B = Prg Product Approval P' 2010 FLORIDA BUILDING CODE - BUILDING 15.37 Where to Symbol PI or P2 or P3 Obtain IntormaUlon Where to find RAS 127Table1orbyanengineering analysis prepared byPE based onASCB7 Descrlptio3 Design Pressure Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier d Product Approval Restoring Moment due to Oravity M Product Approval Attachment Resistance _ Mr Product Approval Required Moment Resistance Mg F' Calculated Product Approval Minimum Attachment Resistance Requited Uplift Resimance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions I.= length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 2010 FLORIDA BUILDING CODE - BUILDING 15.37 M IAMI. DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA # 11- 0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Sub - Category: Material: Roofing Underlayment SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manz facturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Surface Printing) Manufacturing Location #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 MIAMI•DADE COUNTY APPROVED Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 60 mils thick Roll: 32' 10" x 3'33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP -- polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass -fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. MIAMI.DADE COUNTY APPROVED Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 PRI01111 PUSA- 005 -02 -01 PUSA- 018 -02 -01 PUSA- 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103 /ASTM D4798 & G155 TAS 110 /ASTM D4798 & D1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-Y2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre- existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS 1R -Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, and Tile Pro may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. MIAMNDADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 6� Roofing Tiles (6 Max Per Stack) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMI.DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4 "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 8 of 8 MIAM DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /sera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle Low Profile Concrete Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 11- 0321.02 and consists of pages 1 through 10. The submitted documentation was reviewed by Alex Tigera. NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 1 of 10 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Bel Air Concrete Tile Bel Air Double Eagle Concrete Tile Ponderosa Concrete Tile Ponderosa Double Eagle Concrete Tile Golden Eagle Concrete Tile Trim Pieces MIAMI•DADE COUNTY APPROVED Dimensions L = 17" W = 12'A" Thickness ='/2" L = 17" W = 12 '/4" Thickness = 1/2" L= 17" W = 12'A" Thickness = %2" L = 17" W = 12'/4" Thickness = %2" L = 17" W= 12'/4" Thickness = varies w = varies varying thickness Test Product Specifications Description TAS 112 Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. TAS 112 TAS 112 TAS 112 TAS 112 TAS 112 Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Flat profile concrete roof tile with slate finish equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Flat profile concrete roof tile with shake finish equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Flat profile concrete roof tile brushed finish equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 2 of 10 2.1 EVIDENCE SUBMITTED: Test Agency, PRI Asphalt Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. MIAMI•DADE COUNTY APPROVED Test Identifier ERPF- 001 -02 -01 7161 -03 Appendix III 7161 -03 Appendix III 7161 -03 Appendix II P0402 Letter Dated Aug. 1, 1994 P09647 -01 94 -084 25- 7094 -(2, 5, & 8) 25- 7183 -(5 thru 6) 25- 7214 -(1, 5 , & 8) 25- 7487 -2 25- 7496 -(1 & 4) 25- 7804 -6 520109 -1 520111 -4 520191 -1 Calculations Calculations Test Name/Report TAS 112 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Date Aug. 2006 Dec. 1991 Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 Aug. 1994 May 1994 Oct. 1994 Feb. 1995 March, 1995 Dec. 1995 Dec. 1995 Sep. 1996 Dec. 1998 March 1999 Aerodynamic Multiplier Sep. 2006 Restoring Moments Due to Gravity Sep. 2006 NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 3 of 10 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) A (ft3) Batten Application Direct Deck Application Bel Air, Bel Air Double Eagle, 0.301 0.278 Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile MIAMI.DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 4 of 10 Table 3. Restoring Moments due to Gravity - Mg (ft -Ibf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" Greater than 7 ":12" Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth r Screw 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 - : crew 51.7 . 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 50.3 65.5 48.3 1. Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. MIAMI•DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 5 of 10 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Adhesive' 31.32 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 3M 1°' 2- Component Foam Roof Tile Adhesive AH -160 118.93 3M 1m 2- Component Foam Roof Tile Adhesive AH -160 40.44 3 Large paddy placement of 45 grams of PolyProTM. 4 Medium paddy placement of 24 grams of PolyProTM. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft -Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Mortar Sets 43.9 5 Tile -Tite Roof Tile Mortar. MIAMI•DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 6 of 10 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". EAGLEL- FL ORIDA BEL Am, BEL Am DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 7 of 10 PROFILE DRAWING BEL AIR BEL AIR DOUBLE EAGLE MIAMI•DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 8 of 10 PONDEROSA PONDEROSA DOUBLE EAGLE MIAMI•DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 9 of 10 GOLDEN EAGLE END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.:12- 0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 10 of 10 111111111111111111111111111111111111111111111 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO.RP I a. ' I l5 ' Y.AX FOLIO NO. P! -3,006-0/44- 3a50 STATE OF FLORIDA COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. CFN 2012R0435634 OR I?k 28156 Ps 4855; (113s ) RECORDED 176/20/2012 14r07 :13 HARVEY RUVIN, CLERK OF COURT MIAMI -DADE COUNTY, FLORIDA LAST PAGE This Notice of Commencement should be recorded at The Clerk of Courts Miami -Dads County Recorder Courthouse East, 22 NW First Street, 1st Floor, Miami, FL 33128 nn f 1. Legal description of property and street/address: 8535 Ii1.5r:Luir e. l v0� Mi/leo '.l'I 'A331AR 2. Description of improvement: `-"BOO 3. Owner(s) name and address: 1 v<trl K. QfiG0. 4535 Ixayre. plvd rnirtmi 1rn P313' Interest in property: Name and address of fee simple titleholder. 4. Contractor's name and address: 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons with the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1Xa)7., Florida Statutes. Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienors Notice as provided in Section 713.13(1Xb), Florida Statutes. Name and address: 9. Expiration date'of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date 1 E?.ecifi Signature of Print Owners Name Swo h &and subscribed b Notary Public Print Notary's Name My commission expires :. t1 Prepared by <1 , day of i•31(xi. , 20 STATE OF FLORIDA, COUNTY OF DADE I HEREBY CERTIFY that this is a true copy or the oriq{r{�t filed in this office on day of • A.D. 20, 17NESS my hand and r "al SeaL HARVE , ' CLERK, of Circuit Corr Courts B D.C. MARIA MARTINEZ Nohry Public - 8ta M Morino My Comm. Expires Apr 14. 2016 ? Commission • EE 163633 1 4 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 L ING PERMIT APPLICATION FBC20(O Permit Type: UILDING ROOFING. Permit No. Master Permit No. BY: JUN 14 2012 Owner's Name (Fee Simple Titleholder) P2-4-11-ht t r��-'l �D Phone # 1 8ce- 22 I - l ? Owner's Address q 53 1� 41- 4_1 b City"' 1k State Tenant/Lessee Name Email `C VZU1 iC Zip 13Qb Phone # Job Address (wher the work is being done) Ctiss 1 4 -1i 16L` J t - City Miammi Shores Village County Miami -Dade FOLIO / PARCEL # l 9 ?j`pi�lp— 014 Zip Is Building Historically Designated YES NO. Contractor's Company Name piomi (,rl (�1 Contractor's Address (0(e'7 N 1013 Flood Zone hone # r75‘1- 5 City (fl1i icC i i state 1 Zip a5450 Qualifier Name d J e ( R. 004 Z. Phone # State Certificate or Registration No. Certificate of Competency No. 'Contact Phone E -mail v'}i iali YlX]•D-i 17.5 (/.s&ya hap_ CQ� Architect/Engineer's Name (if applicable) �j Q Phone # Value of Work For this Permit $ QD arj. Type of Work: ['Addition ['Alteration Describe Work�leaYO- (ASZIP 1.,bkall Square / Linear Footage Of Work: DNew ►' Repair ❑ Demolition e95TIPN i ald 4 40 p02Qvr bat-rpd S3Ns, iIAM AilA1p di,' .Ar 14Np ae+gd remo) vM , ®l,` 13„ EvtOS .hr ,rlA 4'1103 .mmoll vM r * * ** * * *�* * * * * * * * * * * * ** Fees * * * * * * * * * * * * * * * * *x * * * * * * * * * * * * * * * * *** Permit Fee $ .0%2 ..... Submittal Fee Notary $ Scanning $ Radon $ Double Fee $ Violation date: Structural Review. $ Total Fee Now Due $ Training/Education Fee $ CCF $ DPBR $ CO /CC $ Technology Fee $ Bond $ 3.a. co See Reverse side -� Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that. all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will n be approved and ' J;inspection fee will be charged.. Signature Lob) Owner or A ent The foregoing instrument was ackno ledged before me this Oh day of d , 20 a, by r®f K. f' an .o who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: APPROVED BY (Revised 07 /10 /07)(Revised 06/10/2009) Signature `�G f17/2 Contractor The foregoing instrument was acknowledged before me day of St1rLa- , 20 9 by ravier e who is personally known_to ne or-who has produced as identification and who did take an oath. NOTARY PUBLIC: * * * * * * * * * * * ** • Plans Examiner Engineer f'�1�,� .° . f& A ( !IMF j#+`l�r(`� Ni . ,n. a.� • •� • ibl OrdA v Commission B EE 183633 ••'i �Fe� it`•',, Zoning Clerk checked THIS DOCUMENT HAS A COLORED BACKGROUND • MICROPRINTING • LINEMARKT' PATENTED PAPER AC # DEpARTmENT 6 1 4 9 26 0 STATEPF FLOpF:(513:_sio §aLBlaRg Q# LATIONsE CONSTRucTIoN. INDU TRy LI8EN I . L12060101342 DATE BATCH NUMBER LICENSE NBR kr' 06/01/2012 118196448 CCC068322 The ROOFING CONTRACTOR -? Named below 10 CERTIFIED Under the provisions of. •hapt Expiration date: AUG 31, 2014 MART/NEZ`, :JAVIER. ROLANDO MIAMI ROOFING SYSTEMS INC 7552 BUCCANEER AVENUE NORTH BAY VILLAGE FL 33141 RICK SCOTT GOVERNOR KEN LAWSON SECRETARY Property Information Map My Home Miami -Dade County, Florida Property Information Map Aerial Photography - 2009 0 — This map was created on 6/11/2012 1:49:53 PM for reference purposes only. Web Site ® 2002 Miami -Dade County. All rights reserved. Clan 114 ft Page 1 of 1 Summary Details: Folio No.: 11- 3206 - 014 -3050 Property: 9535 BISCAYNE BLVD Mailing FRANK BLANCO Address: MARIA C BLANCO Living Units: 9535 BISCAYNE BLVD Adj Sq Footage: MIAMI FL Lot Size: 33138- Pro perty Information: Primary Zone: 1100 SINGLE FAMILY RESIDENCE CLUC: 0001 RESIDENTIAL - SINGLE FAMILY Beds/Baths: 4/3 Floors: 2 Living Units: 1 Adj Sq Footage: 2,855 Lot Size: 8,056.10 SQ FT Year Built 1976 $25,000/ $339,249 MIAMI SHORES SEC 3 PB 10-37 PT LOTS 12 & 13 BEG AT NWLY COR Legal LOT 13 RUN NELY75FT Description: ALG E R/W /L BISC BLVD SELY135.85FT SWLY35.53FT NWLY130FT TO POB BLK 76 Assessment Information: Year: 2011 2010 Land Value: $114,766 $121,037 Building Value: $241,783 $243,212 Market Value: $356,549 $364,249 Assessed Value: $356,549 $384,249 Exemption Information: Taxable Value Information: Year 2011 2010 omestead: $25 000 $25 000 r nd Homestead: YES YES Taxable Value Information: Year 2011 2010 Taxing Authority: Applied Exemption/ Taxable Value: Applied Exemption/ Taxable Value: Regional: $50,000/ $306,549 $50,000/ $314,249 County: $50,000/ $306,549 $50,000/ $314,249 $50,000/ $314,249 City: $50,000/ $306,549 School Board: $25,000/ $331,549 $25,000/ $339,249 Sale Information: Sale Date: 1/2011 Sale Amount: $300,000 Sale O /R: 27994 -1304 Sales Sales qualified as a result Qualification of examination of the Description: deed View Additional Sales http: / /gisims2 .miamidade.gov /myhome /printmap. asp? mapurl = http: / /gisims2.miamidade.go... 6/11/2012 Miami Shores Viiiage Building Department. 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: C. Property Address: Roofing Permit Number: Dear Building Official: Date: ____Latilta_____ building because: certify that I am not required to retrofit the roof to wall connections of my /The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach taxation. ttach proof of ad ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 199 _dition of the 1ui Florida Building Code (1994 SFBC) Signa re �ra(11L Iti Q Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he /she is the owner for the above property mentioned. Swom to and subscribed before me this 11 day of -sunk, j c� Notary Public, Sate of Florida at Large • When the just valuation of the structure for purpose of ad valorem twat( SFBC. Then you must provide a building application from a General Co Revised on 5/21/2009 s not constructed with FBC nor a 1994 !RFCFIJVED JUN �. 4 2012 Florida Building Code Edition 2007 Igh- Velocity Hurricane Zone Uniform Permit Application Form. SECtian A ((�anpral Infnrrn finni Process No. 12,-r I Z - 1®9 7- Contractor's Name M; ryt j \ o3- or �y s 5 Job Address 9r-� 1 S� ❑ Low Slope ❑ Asphaltic Shingles ROOF-CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof XReroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF 3945 Sketch Roof Plan: Spy #ion B (Roof Plan) Include dimensions Illustrate sections and levels, clearly identify dimensions of,elevated pressure zones o and location of parapets. ❑ Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes Maintenance o I (SF) tio945 -' y7]1 IIIIaqj MINN i 1 1E1 lint ■■■■Iw��■■ VIII Rimmaitmanz6mmommum � FLORIDA BUILDING CODE — BUILDING Shores Village- ' BY 'r` PACE 'A/I rH ALL FEOFRAL ,L l(1f Arioy- s3afLL3na1s dOldOON ONV S3116W3sS1/ 40O?I ___ ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section F (Tile Calculations) For Moment based tile systems, choose tither Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mr values are greater than or equal to the Mr values, for arch area of the roof, thcn the tilt attachment method is acceptable. Method I "Moment Based Tile Calculations Per RAS 127" �/�o r1n 2 3 ull i-4B V, x. o�rt r6�8G = ��/�.'�� Mg: 7.5 9 =ctrl p3i. 7 g Product Approval Mr 31.3 (P_: c%^^ f.3x).r0^`n/rD/ =!%�p7. Mg: d/�•59 =Mi2 AZ°23 Product Approval Mr?5(.3.3 (P ;: IO J. k l .d /a =° f.3c) Mg: /.,'�9 = M 3 al'. Product Approval Mr 31. Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mr Mr required Moment Resistance* Mean Roof Height -- Roof Slope 16' 1 20' 26' 30' 40' 2:12 34.4 I 38.5 38.2 39_7 42.2 3:12 32.2 34.4 38-0 37.4 39.8 4:12 30.4 1 32.2 33.8 36.1 37.3 6:12 28.4 1 30.1 31.8 32.8 34.9 6:12 28.4 1 28.0 29.4 30.5 32.4 7:12 24.4 1 25.9 27.1 28.2 30.0 ,Must be used in conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F" with the values for Fr. If the F' values are prawn= or equal to the Fr values. for each area or the roof, then the tilt attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (Pt: x L = x w: = j - W: x cos 0 = Fri Product Approval F' (P2: x L = x w: = ) - W: x cos 0 = Fr2 Product Approval h" (P3: x L = x w: = 1 W - --- " - • r5 • A WM.. npp.vrai r Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table t or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity Ma Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance M 5 Calculated Minimum Attachment Resistance F' Pmduct Approval Requited Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L= length W = width Product Approval AU calculations must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING MIAMI DiADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) andfor the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle Low rofile Concrete Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07- 1018.08 and consists of pages I through 9. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED NOA No. :11- 032L02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. • For locations where the pressure requirements, as determined by applicable Building •Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Bel Air Concrete Tile Bel Air Double Eagle Concrete Tile Ponderosa Concrete Tile Ponderosa Double Eagle Concrete Tile Golden Eagle Concrete Tile Trim Pieces MIAMI•DADE COUNTY APPROVED Dimensions L= 17" W =12'A" Thickness =' /a" L = 17" W = 12 'A" Thickness = %z" L= 17" W =12'A" Thickness = 'A" L = 17" W =12'A" Thickness =1/2" L= 17" W =12'A" Thickness =IA" 1= varies w = varies varying thickness Test Product Specifications Description TAS 112 Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. TAS 112 Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. TAS 112 Flat profile concrete roof tile with slate finish equipped with two nail holes. For adhesive set, direct deck or battened nail - on applications. TAS 112 Flat profile concrete roof tile with shake finish equipped with two nail holes. For adhesive set, direct deck or battened nail - on applications. TAS 112 Flat profile concrete roof tile brushed finish equipped with two nail holes. For adhesive set, direct deck or battened nail - on applications. TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No. :11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 2 of 9 2.1 EVIDENCE SUBMITTED: Test Asencv FRI Asphalt Technologies Redland Technologies Redland Technologies Redland Technologies 1 Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied 'Engineering, Inc. The Center for Applied Engineering, lnc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. , Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. MIAMIOADE COUNTY APPROVED Test Identifier ERPF - 001 -02 -01 7161 -03 Appendix III 7161 -03 Appendix III❑ 7161 -03 Appendix II P0402 Letter Dated Aug. 1, 1994 P09647 -01 94 -084 25- 7094 -(2, 5, & 8) 25- 7183 -(5 thru 6) 25- 7214 -(1, 5 , & 8) 25- 7487 -2 25- 7496 -(1 & 4) 25- 7804 -6 520109 -1 520111 -4 520191 -1 Calculations Calculations Test Name/Reuort TAS 112 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier Restoring Moments Due to Gravity Date Aug. 2006 Dec. 1991 Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 Aug. 1994 May 1994 Oct. 1994 Feb. 1995 March, 1995 Dec. 1995 Dec. 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 Sep. 2006 NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 3 of 9 3. LL IITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless •stated•otherwise by the underlayment materiat"-rrianufacturers published. literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofmg Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofmg Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Fiat Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A 3 Direct .,- ' is • tion Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile - 0.301 < 0.278 MIAMIOADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 4 of 9 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf} Tile Profile 3 ":12" 4" :12" 5 ":12" 6 ":12" Greater than 7" :12" Bel Air, Bel Air Double Eagle, 9 Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Batten s Direct Deck Battens Direct • . `�` Battens Direct Deck Batten s Direct Deck Batten s Direct Deck 7.48 7.71 7.37' 7.59 ---- ) 7.22 7.44 • - 7.05 . 7.27 6.86 7.07 Table 4: Attachment Resistance Expressed as a Moment - Mz (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Bel Air, Bel Air Double Eagle, Ponderosa , Golden Eagle, Ponderosa Double Eagle Flat Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails • 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Naiis1 50.3 65.5 48.3 1. Installation with a 4" tile headlap and fasterners are located a min. of 234" from head of tile. MIAMI•DADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 5 of 9 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Adhesive2 31.33 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 6: Attachrment'Resistance for Single Patty Expressed'as a Moment - Mf (ft-lbf) Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bel Air, Bel Air Double Eagle; Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile PolyProTM 118.94 PoIyProTM 40.43 3 Large paddy placement of 45 grams of PolyProTM. 4 Medium paddy placement of 24 grams of PoIyProTM. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar or AdhesiveSSet Systems.: Tile Profile Tile Application Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Mortar Sete 43.9 Tile -Tite Roof Tile Mortar. 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". 41:L.E1 FLORIDA u►MI.DAD COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 6 of 9 BEL AIR, BEL AIR DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) MIAMbDADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 7 of 9 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING BEL Am DOUBLE EAGLE MIAMI DADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 8 of 9 I 1.. PONDEROSA MIAMIDADE COUNTY APPROVED PONDEROSA DOUBLE EAGLE NOA No.:11- 0321,02 Expiration Date: 10/05/16 Approval Date: 05 /12/11 Page 9 of 9 GOLDEN EAGLE END OF THIS ACCEPTANCE MIAMI.DADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/I6 Approval Date: 05/12/11 Page 10 o19 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. \r Aesthetics•Wortcmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. ` Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. At Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. - Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. s Ponding water: The current roof system and/or deck of the building may not drain well and ma y cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. (Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the inten of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It maybe beneficial to consider additional venting which can result in extending the service life of the goof. r Owneir/Agents Skinature Date Contractgr'Signature Revised on 7/9/2009 LD Date