Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-12-775
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 nspection Number: INSP- 177629 Permit Number: RF -5 -12 -775 Inspection Date: August 21, 2012 Inspector: Bruhn, Norman Owner: INVESTORS LLC, SLP RESIDENTIAL Job Address: 54 NE 100 Street Miami Shores, FL 33138- Project <NONE> Contractor: MASIMO CONSTRUCTION INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number (954)243 -8197 Parcel Number 1132060131210 Phone: (954)701 -7425 Building Department Comments RE ROOF FLAT ROOF Passed i Inspector Comments CREATED AS REINSPECTION FOR INSP- 177490. CREATED AS REINSPECTION FOR INSP - 177319. CREATED AS REINSPECTION FOR INSP- 172987. Not ready NB NO WEEPING HOLES ON FLAT. SEAL COUNTER FLASHING AND FEASTNERS. JR NO LADDER, NO PERMIT JR. d i./ Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until August 21, 2012 For Inspections please call: (305)762 -4949 Page 1 of 1 BUII mG5/645 PERMIT APPLICATION Master Pert No. FBC 20 Miami Shores Villa Building DepartmentB Y: -- - - -- 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. l5- Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): SLP lee5kN& a\ - NVPA'wLS Phone#: `MA. 1.,t3 5l°0 • Address: kk)U (V•441 4:F ��IV City: t ki0lMi State: Zip: "b U'" t Tenant/Lessee Name: N A - Email: 01 -E. 4� IOWACa Q +ol\CO' • Cf • Phone*. JOB ADDRESS: 6 4 IJ 1OO SI* City: Miami Shores County: Miami Dade Tap: Folio/Parcel#: Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: Masimo Construction, Inc- phoae#:9547017425 Address: 1 61 05 83 Place North �� ����� City: Loxahatchee State: Florida 73470 QualifierName: Bradley S Pollack phone#: 9547017425 State Certification or Registration #: CCC1 328033 Certificate of Competency #: Contact phone#: 954701 7425 Email Address: brad @masimoconstruction. com DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 211°0 Square/Linear Footage of Work: 50 0 Type of Work: ©Addition °Alteration Mew ORepair/Replace Demolition Description of Work: Re —roof flat f p•1Q#. Teeze e„ ss********* ***** * ***** **** ►* m**** *F e+r*m***** * ******* rs*e*ae*»v * * *****soo***** Submittal Fee $ Permit Fee $ )SO CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Tralning/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) I./k' • Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IIVIPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITII YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which oc seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be app 4 a reinspection fee will be charged The fore day o: who is personall Owner or Agent As identification and who did take an oath. NOTARY PUBLIC: me or who has produ ehtification and who did take an oath. LIC: Zoning Structural Review Clerk (Revised 07 /10XY7)Revised 06/102009)(Revised 3/15/09) z4n 4k;tt sit "4 DATE BATCH NUMBER DATE E 13ATCii N.UMBER L *.;;N:ettie:iit: • • ••• a. --tTOR of C ndatei BUG • TAY s14 CT' N ORTA: L 3 4 ;.r OR BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 8. Andrews Ave., Rm. A-100, Ft Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1,2011 THROUGH SEPTEMBER 30,2012 DBA: Business Name: MASIMO CONSTRUCTION INC Owner Name: BRADLEY STEVENSON Business Location: 16105 83 PLACE NORTH PALM BEACH COUNTY Business Phone: 954-303-2018 Rooms Receipt #:185-179,3 B iness T ROOFING / SMUT METAL CO usype* , 'keERT ROOFING CONTRACTOR) Business Opened:02/05/ 2008 StateiCounty/OertfReg:CCC1328033 Exemption Code:NMExEMPT Professionals For Vending Susi Number of Machines: Only Vending Type: Tax Amount Transfer Fee % "•::.,20,L ...'i ...„,...,.....,......... .......,.........,...... • • , . .... ,,,. , , . ......, 'liggiglt glihmePrd:,,Y '''..''''':%'''',-k4. , • Collection Cost . Total .Pold 27 . 0. Q 3,60 g ISRA;;44,166 4Moogka0l0e-N.**A , J 0.00 0.00 30.00.• THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Sroward County and is non-regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in conpliance with State or local laws and regulations. MaMng Address: BRADLEY STEVENSON 16105 $3 PLACE NORTH LOXAHATCREE, FL 33470 201 -2012 Receipt #00,-10-00011977 Paid 09/08/2011 30.00 03 -01 -2012 JEFF ATWATER STATE OF FLORIDA CHIEFFINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: PERSON: FEIN: 03/01/2011 EXPIRATION DATE: 02/28/2013 POLLACK BRADLEY S 203016640 BUSINESS NAME AND ADDRESS: MASIMO CONSTRUCTION INC 16105 83RD PLACE NORTH LOXAHATCHEE FL 33476 SCOPES OF BUSINESS OR TRADE: 1- GENERAL CONTRACTING 2- ROOFING IMPORTANT: Pursuant to Chapter 440 . 0504), F,S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under Ibis section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), FS, Certificates of election to be exempl... apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13}, F.S. Notices of election lo be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the cerlificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. DWC -252 CERTIFICATE OF ELECTION 10 BE EXEMPT REVISED 01 -11 QUESTIONS? (850) 413 -1609 PLEASE CUT OUT THE CARD BELOW AND RETAIN FOR FUTURE REFERENCE STATEO FFLORIDA DEPARTMENTO F FINANCIAL SERVICES DIVISIONOFWORKERS' COMPENSA'I'ION CONSTRUCTION INDUSTRY CERTIFICATEO F ELECTION TO B EEXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW EFFECTIVE 03/0112011 exp I RAT ON DATE:. 02/28 PERSON: BRADLEY S POLLACK FEIN: 20301 6 6 4 0 BUSINESS NAME AND ADDRESS: MASIMO CONSTRUCTION INC 16105 83RD PLACE NORTH LOXAHATCHEE, FL 33476 SCOPE OF BUSINESS OR TRADE: 1- GENERAL CONTRACTING 2- ROOFING 2013 IMPORTANT dPursuant to Chapter 440.05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election �- under this section may not recover benefits or compensation under this D chapter. Pursuant to Chapter 440.05(12), FS, Certificates of election to be H exempt... apply only within the scope of the business or trade listed on Rthe notice of election to be exempt. E Pursuant to Chapter 440.05(13), FS., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. QUESTIONS? (850) 413 -1609 CUT HERE * Carry bottom portion on the job, keep upper portion for your records. DWC -252 CERTIFICATE OF ELECTION 10 BE EXEMPT REVISED 01 -11 ' °, CERTIFICATE OF LIABILITY INSURANCE °A'E D° ) L °4124112 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: It the certificate holder is an ADDITIONAL, INSURED, the policy(ies) must be endorsed. If SUBROGATION 15 WAIVED, subject to the terms and conditions of the policy, certain pollees may require an endorsement A statement on this cetificate does not confer rights to the i certificate holier in lieu of such endorsement(s). PRODUCER J & J Insurance Associates 7037 -B Taft St. Hollywood, FL 33024 Phone (954) 8935558 INSURED 1 MASIMO CONSTRUCTION INC 16105 83 PLACE NORTH LOXATACHEE Fax (954) 893.117.4 ooNTACT JOSEPH F BRACCIO NAME: I F rtioN� r ( ) 8935558 1 s C, Nok (954) 893 -1174 D Lac: j�._.ins9otbellsouth.nst FL 33469 INSURERS) AFFORDING QOV0RAGE NAIL s INSURER A : UNITED STATES SPECIALTY INSURANCE INSURER B; INSURER C : Iti5URSR D : INSURER E COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS 1S TO CERTIFY THAT THE POLICIES OF INSURANCE USTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, • EXCLUSIONS AND CONDT27ONS OF SUCH POLICIES. LWITS SHOWN MAY HAVE BEEN REDUCED SY FPAID CLAIMS. _ Ili jTZ l TYPE OF INSURANCE ADOLSUBR iMMtDDI Y_�LYJ mPOLID1NYYYL I 1NSR WVD POLICY NUMBER LIMITS GENERAL UABRITY i ® COMMERCIAL GENERAL LIABILITY 1 ❑ ❑ CLAIMS -MADE © OCCUR 0 0 GENL AGGREGATE LIMIT APPLIES PER 1 El POLICY El !IN-.- LOC AUTOMOBILE UABILITY r0 ANY AUTO t . i AUTOS NED ❑ AAUT ❑ HIRED AUTOS 0 ALrlitINNED i❑ ❑ 1 ❑ UMBRELLA UAB ❑ occur ❑ EXCESS LIAR ❑ ciiiim •MADE 1 ❑ DED ❑ RETENTION 5 1 WORKERS COMPENSATION 1 AND EMPLOYERS LIABILITY Y 1N ANY PROPRI&TORlPARTNEMIDCECURVE OFFICER/MEMBER EXCLUDED? N 1 A I (Mandamryln M4) I if deanle under ..._� DE�SCRiFTIt?N OF OPERATIONS below NS1212195 • 01/25/2012 01/26/2013 EACH OCCURRENCE DAMAGE TO RQdnED PREMISES occurrence s 1.000,000.00 $ 100,000.00 MED EXP (My one n $ 5,000,00 PERSONAL & ADV INJURY s 1,000,000.00 GENERAL AGGREGATE r $ 2,000,000.00 PRODUCTS - COMP /OP AGO I $ S DEsclarTLON Of OPERATIONS! LOCATIONS! VEHICLES (Attach ACcom lot. Admen! Rowans Schedule. Wilms space Is required) GENERAL CONTRACTOR CERTIFICATE HOLDER VILLAGE OF MIAMI SHORES 10050 NE 2 AVE MIAMI SHORES FL 33138 -2301 305. 756 -5972 ACORD 25 (2010105) QF 300 /300'd 99L9# CtI9MrSINGLE OMIT (BODILY INJURY (Per person) S BODILY INJURY (Per amide OPPER ef ■AMAGE EACH OCCURRENCE AGGREGATE . . • I $ - __ _•••• $ (}(i ❑ TT RY'LAMIIUTS ❑ ER i E.L. EACH ACCIDENT $ EL DISEASE - EA EMPLOYER 5 E.L.DISEA:E- POLICY LIMIT S CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED ED BEFORE THE EXPIRATION DATE + s. eTICE WILL BE DELIVERED IN ACCORDANCE WITH TH - . I CY P - ■ VISIONS. AUTHORBED REPRES JOSEPH F BRAG 588 -2010 ACO D CORPORATION. All rights reserved. e ACORD name and logo are registered marks of ACORD t'LLL8681796 06 :00 Z1.06/9Z/V0 Miami Shores Viage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: Scd y rrq\ Property Address: 54 fly) ser- , Nltkvini Roofing Permit Number: Dear Building Official: I SkESTA;e-.1 - certify that I am not required to retrofit the roof to wall connections of my builpg because: he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad just prP p valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions Date: t-I /VA /r? r1 L of 19• - - • • •f . •Lo South Florida Building Code (1994 SFBC) j Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he /sh is the owner for the above property mentioned. Swom to and subscribed before me this 1 day of Notary Public, Sate of Florida at Large CLAUDIA V. CUBILLOS o.�` Vs Notary Public - State al Florida rt '� . My Comm. Expires Sep 2015 2 sir. • Commission # EE Assn ; o-,g Bonded Through National Notary • When the just valuation of the structure for purpose o ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Miami-Dade My Home My Home Show Me: I Ropetly ttinetbn Search By: SeleT cT—ienn f1 xtony on! ppraiser Tax Estimator 1-j Property, Appraiser Tax Comparison Summary Details: 'Folio No.: 1132O6Oi3 • :„,,Aa . NE 100 ST +LP RESDENTIAL • .ress: INVESTORS LLC • tsE 100 ST MIAM SHORES L cc 38_ Property Information: 1000 SINGLE FANNY 1CLUC: 1 1141 RESIDENTIAL - + INGLE FM/LT : - . s/l3aths: 3 3/1 Floors: 1 1 nrin ! Units: 1 1 • 1 Sq Footage: , ,490 Property Information: Primary Zone: E 1000 SINGLE FANNY 1CLUC: 1 1141 RESIDENTIAL - + INGLE FM/LT : - . s/l3aths: 3 3/1 Floors: 1 1 nrin ! Units: 1 1 • 1 Sq Footage: , ,490 'Lot Sze: ' '8,625 80 FT 'Year Built: 1 1941 • SHORES SEC 1 • D P8 10-70 LOT 6 & egal 1 1/2 OF 5 BLK 9 LOT crftftlen: + + VE 75.000 X 115 COC f ....1-0725 01 2005 1 OR e :110-0872 0212 01 Assessment Inforination: Tear: " 2011 2010 Land VI:due: $74,261 $77,798 Building Value: $188,618 $188,618 Market Value: $262879 $266,416 'Assessed Value: $262,879 $266,416 Taxable Value Informabon: r: 2011 2010 APPIled APPlied ,,,. Exemption/ Exemption/ axing --"—`''' Taxable Taxable Vslue: Mrilue: Oegionat $0/$26Z879 $0/$266,416 'County: $0/$262,879 $0/$266,416 City. $0/$262,879 $0/$268,418 School Board: $0/$262,879 $0/$266,416 Sale Information: 'Sale Date: 'Sale Amount 0/R: 12 000 0- 72 s uardication •C .ion: Sales quaffed as a result examination of the deed levy Additional Sales Additional Information: Click here to see more information for this pr7perty: Community Development District http://gisims2.miamidade.gov/myhome/propmap.asp ACTIVE TOOL: SELECT Aerial Photography- 2009 ser-isr ARIL. My Home 1 Prop e,' , „iation I Property Taxes I My Neiqhborhoco I Property Appraiser 0 111ft Home 1 'Jsinq Our Site !Phone Directory I Privacy Disclaimer if you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at VVelamaster, Web Site 0 2002 Mani-Dade County All rights reserved. MIAMIDADE Legend Property Boundary Selected Property Street Highway Mlami-Dade County Wide 1 of 2 4/20/2012 5:30 PM Taxable Value Informabon: r: 2011 2010 APPIled APPlied ,,,. Exemption/ Exemption/ axing --"—`''' Taxable Taxable Vslue: Mrilue: Oegionat $0/$26Z879 $0/$266,416 'County: $0/$262,879 $0/$266,416 City. $0/$262,879 $0/$268,418 School Board: $0/$262,879 $0/$266,416 Sale Information: 'Sale Date: 'Sale Amount 0/R: 12 000 0- 72 s uardication •C .ion: Sales quaffed as a result examination of the deed levy Additional Sales Additional Information: Click here to see more information for this pr7perty: Community Development District http://gisims2.miamidade.gov/myhome/propmap.asp ACTIVE TOOL: SELECT Aerial Photography- 2009 ser-isr ARIL. My Home 1 Prop e,' , „iation I Property Taxes I My Neiqhborhoco I Property Appraiser 0 111ft Home 1 'Jsinq Our Site !Phone Directory I Privacy Disclaimer if you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at VVelamaster, Web Site 0 2002 Mani-Dade County All rights reserved. MIAMIDADE Legend Property Boundary Selected Property Street Highway Mlami-Dade County Wide 1 of 2 4/20/2012 5:30 PM Sale Information: 'Sale Date: 'Sale Amount 0/R: 12 000 0- 72 s uardication •C .ion: Sales quaffed as a result examination of the deed levy Additional Sales Additional Information: Click here to see more information for this pr7perty: Community Development District http://gisims2.miamidade.gov/myhome/propmap.asp ACTIVE TOOL: SELECT Aerial Photography- 2009 ser-isr ARIL. My Home 1 Prop e,' , „iation I Property Taxes I My Neiqhborhoco I Property Appraiser 0 111ft Home 1 'Jsinq Our Site !Phone Directory I Privacy Disclaimer if you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at VVelamaster, Web Site 0 2002 Mani-Dade County All rights reserved. MIAMIDADE Legend Property Boundary Selected Property Street Highway Mlami-Dade County Wide 1 of 2 4/20/2012 5:30 PM CP rmit No: 12 -775 Job Name: May 2, 2012 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Building Critique Sheet 1) RAS 150 has not been adopted by Miami Dade. Provide product approvals and a completed section C. Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and inclu • se o v'_• eets in the re- submittal drawings. 4-1frug----- CO /lit 44--1 Ca, t( SZet 4 EMBUES AND ROOFTOP STRUCTURES Miami Shores APPROVED ZONING DEPT ®Y Village DATE �s � �/ Florida Building Code Edition 2007 0 G DEPT 1°' High - Velocity Hurricane Zone Uniform Permit Applie ` 9.ea c ' ` TO COMP LANCE NTH ALL FEDERAL I STATE AND COUNTY RULES AND REt3ULATONS Section A (0011Bral Infnrmatinn Master Permit No. Process No. Contractor's Name Massimo construct ion.. Inc .. Job Address CJ, 1. Kam' c'r M Work 01.0fe-5 1• ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile Asphaltic ❑ Metal Panel /Shingles ❑ Wood Shingles /Shakes Shingles IR Prescriptive BUR -RAS 160 ROOF TYPE ❑ New Roof a Reroofing ❑ Recovering ROOF SYSTEM INFORMATION ❑ Repair ❑ Maintenance Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) sno 0 500 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. FLORIDA BUILDING CODE — BUILDING 1 'E -tooF 'Ir`><. +b'1o40 flwr- 2oo F OVea. 'i'1r1at ct• • t ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hunicane Zone Unfform Permit Application Form. Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer. 6AF. Product Approval No.: v 7. 10L /f f / Design Wind Pressures, From RAS 128 or Calculations: Pmax1: 42. 8 Pmax2: 71 .7 Pmax3:108.0 Max. Design Pressure, from the specific Product Approval system: � 3400.+.. Deck: Type: CHX Plywood GaugelThickness: 5/8" Slope: 1/8:1 Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener /Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): #75 1 Ply Surfacing: (rau1e8 Fastener Spacing for Anchor/Base Sheet Attachment: Field: 9 " oc @ Lap, # Rows 2 @ 9 " oc Perimeter 6 " oc @ Lap, # Rows4 @ 6 " oc Corner: 6 " oc @ Lap, # Rows 4 @ 6 " oc Number of Fasteners Per Insulation Board: Field /1/4 Perimeter ja Corner ___ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit ;IS /Are Base Sheet Fastener /Bonding Material: 1 1/4" rs coil nails 1 5/8" tin tabs Ply Sheet(s) & No. of Ply(s): 2 Plies Ply IV Ply Sheet Fastener /Bonding Material: Tint mypp TV asphalt Top Ply: granulated cap sheet Glass Top Ply Fastener/Bonding Material: Hot Type TV asphalt FLORIDA BUILDING CODE — BUILDING FT. Parapet Height t 1—a" Mean Roof Height 56Aae SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. SO Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. O Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. kii Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. SO Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. q® Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. 50 Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduce• . , /se beneficial to consider additional . venting which can result in extending the service life of the g�I` 0 ' gnature Date Revised on 7/9/2009 LD Contractor Signature Date M IA DA[}C =. BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation. 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the u ' construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). • MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE I603 MIAMI, FLORIDA 33130 -1563 (305) 375 -290I FAX (305) 375 -2908 This NOA shall not be valid after the expiration date stated below. The Miami -Dade. County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 throygh 19. The submitted documentation was reviewed by Jorge L. Acebo. (!) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 1 of 19 ROOFING SYSTEM APPROVAL Category: Sub -Ca Deck Tune, Maximum D TRADE NAME Roofing BUR Wood n Pressure -75 psf Product OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Leak BusterTM MatrixTM 307 Premium Asphalt Primer GAF Mineral ShieldTM Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM Matrix"' 322 Elastomeric Roof Coating LeakBusterTM MatrixTM Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 204 Wet/Dry Roof Cement RUBEROID® Modified Bitumen Flashing Cement LeakBusterTM MatrixTM 201 Premium SBS Flashing Cement GAFGLAS® #75 Test Dimensions Specification 5, 55 gallons ASTM D 41 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. 60 & - +0 lb. bags ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. 5 gailo ASTM 1227 Surface coating for smooth surfaced roofs. 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 5 gallons 5 gallons ASTM D 2824 Fibered aluminum coating. Elastomeric roof coating. Asphalt emulsion fibered. ASTM D -4 6 Refined asphalt blended with a mineral ASTM D-340 stabilizer and fibers. Permits adhesion to et and dry surfaces. ASTM D 4586 Fi, er reinforced, polymer modified Flashing cem, t ASTM D 4586 Asphalt shing Cement 39.37" (1 meter) ASTM D 4601 Asphalt impregn wide base sheet. ed and coated glass mat NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 Product GAFGLAS® #80 ULTIMATM Base Sheet GAFGLAS® Flex P1yTM 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS Flashing GAFGLAS® STRATAVENT® EliminatorTM Nailable RUBEROID® SBS Heat We1dTM Smooth RUBEROID SBS Heat- We1dTM Granule RUBEROID® SBS Heat- We1dTM 170 FR RUBEROID® SBS HeatWeldTM PLUS RUBEROID® SBS Heat- WeldTM PLUS FR RUBEROIDD SBS Heat- We1dTM 25 RUBEROID® Modified Base Sheet Dimensions 39.37" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide Various 39.37" (1 meter) wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) wide Test Specification ASTM D4601 ASTM D 2178 ASTM D 2178 ASTM D 3909 ASTM D 3909 ASTM D 4897 D 3672 ASTM D 4897 D 3672 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D4601, Type II, UL Type G2 BUR Product Description Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT®EnergyCoteTM. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with . polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07- 1219.09 Expiration Date: 11104/13 Approval Date: 03/20/08 Page 3 of 19 Product RUBEROID® 20 RUBEROID® Mop Granule RUBEROID® Mop Plus (Granule) RUBEROID® MOP Smooth RUBEROID® MOP 170FR RUBEROID® MOP FR RUBEROID® TORCH Smooth RUBEROID® TORCH Granule RUBEROID'TORCH PLUS (Granule) RUBEROID® TORCH FR RUBEROID®170FR TORCH RUBEROID® 30 RUBEROID® 30 FR RUBEROID® ULTRACLAD® RUBEROID® Dual FR Vent Stacks (metal and plastic) MIAM _ _ OU TY APPROVED Dimensions 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39,37" (1 meter) wide 39.37" (1 meter) wide 39.37" (I meter) wide 39,37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 3937' (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37' (1 meter) Wide Test Specification ASTM D 6163 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTMD5147 ASTM D 5147 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 TAS 100(A) ASTM D 1929 ASTM D 635 Product Description SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Asphalt impregnated, coated felt, surfaced with mineral granule. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Woven fiberglass mat coated with Polymer modified asphalt and surfaced with aluminum, copper or stainless steel foil. Non-woven polyester and fiberglass mat coated with file retardant, polymer modified asphalt and surfaced with mineral granules. One way valve vent used to relieve built-up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 4 of 19 Product Leak BusterTM MatrixTM 302 Non Fibered Aluminum Roof Coating GAF Built -Up Roofmg Asphalt RUBEROID® MOD Asphalt, Asphalt L & Asphalt P Leak BusterTM MatrixTM 602 Leak BusterTM MatrixTM 715 LeakBusterTM MatrixTM 531 WeatherCoteTM SeamCoteTM FireOutTM VersaShield® VersaShieId® FB -1S VersaShield® FB -2S TOPCOAT® FireShield® MB Leak BusterTM MatrixTM 201 SBS Flashing Cement Leak BusterTM MatrixTM 102 SBS Adhesive Leak BusterTM Matrix'JM 202 SBS Flashing Cement Leak BusterTM MatrixTM 203 Plastic Roof Cement Leak BusterTM MatrixTM 103 Cold Process Adhesive MIAMI DADE • UNTY APPROVED Dimensions 5 gallons 100 lb. cartons, bulk 601b. kegs 5 gallons 5 gallons 2 gallons 2, 5 gallons 5, 55 gallons 350 sq ft. roll 350 sq ft. roll 350 sq ft. roll 5, 55 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons Test Specification Product Description ASTM D2824, Non- fibered aluminum pigmented, asphalt Type 1 roof coating. ASTM D312, Types I, II, III and W proprietary ASTM D -412 ASTM D -21 -96 ASTM D1475 ASTM E -1644 ASTM D3019 ASTM D3019 ASTM D4586 ASTM D4586 ASTM D3019 Interply mopping and surfacing asphalt. SEBS modified asphalt. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Elastomeric roofing membrane. Low VOC, fire barrier coating. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Elastomeric roofing membrane Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement Cold Applied Asphalt Adhesive. NOA No.: 07- 1219,09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 5 of 19 Product Leak BusterTM MatrixTM 303 Fibered Aluminum Roof Coating Leak Busteem MatrixTM 304 Non Fibered Aluminum Roof Coating Test Dimensions Specification 5 gallons ASTM D 2824 5 gallons APPROVED INSULATIONS: Product Name EnergyGuardTM RA, RN Composite A & N EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANTTM EnergyGuardTM Permalite Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Perlite EnergyGuardTM High Density Fiberboard EnergyGuardTM Composite EnergyGuardTM Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck', Dens Deck® Prime, Dens Deck® Dura GuardTM Structodek SecurockTM Product Description Fibered aluminum coating. ASTM D2824, Non- fibered aluminum pigmented, asphalt Type I roofcoating. Table 2 Product Description', Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Tapered perlite board Perlite insulation board High density wood fiberboard insulation. Polyisocyanurate /wood fiberboard composite Polyisocyanurate /wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board Manufacturer (With Current NOA) BMCA ' GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. BMCA BMCA generic generic generic G -P Gypsum Corp Knight Celotex USO Corporation NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: Fastener Number Product Name 1. Dri11 -TecTM 1112 Standard, 1114 and 415 extra Heavy Duty Fastener , Heavy Duty Roofing Fastener 2. Drill -TeeTM ASAP 3. Drill-Teem" 412 or #14 Standard screws with AccuTrac Plate 4. Drill -TecTM Galvalume Plates 5. Drill -TecTM Polypropylene Plates 6. Drill -TecTM AccuTrac Plate EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. PRI Asphalt Technologies, Inc. IItT of S. Fl. TABLE 3 Product Description Insulation fastener and Base Play fastener for steel, wood & concrete decks. Pre - assembled Drill - TecTM Fasteners and metal and plastic plates. Base sheet fastening assembly. Round Galvalume stress plates. Round polypropylene stress plates. Square Galvalume® coated steel plate. Test Identifier J.I. 2B8A4.AM J.I. 3B9Q1.AM J.I. ODOA8.AM J.I.ODIA8.AM J.I.0X9Q5.AM 3029832 GAF - 012 -02 -02 GAF- 020 -02 -01 02 -005 02 -014 Manufacturer Dimensions (With Current NOA) Various GAF Materials Corp. Various GAF Materials Corp. Various GAF Materials Corp. 3" and 3 W GAF Materials Corp. 3" and 3 1/2" GAF Materials Corp. 3" Square GAF Materials Corp. pescription 4470 4470 4470 4470 -TAS 114 4470 - TAS 114 4470 - TAS 114 Physical Properties ASTM D 4977 TAS 114 TAS 114 . Date 07.02.97 01.08.98 07.09.99 07.29.94 04.01.98 05.11.07 11.06.01 02.01.02 01.18.02 03.22.02 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page7of 19 APPROVED ASSEMBLIES Deck Type L• Deck Descrip 'on: Wood, Insulated • 19/82" or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and Sys m Limitations shall apply. One or more layers of ; of the following insulations. . Insulation Layer (Table ) Insulation Fasteners Fastener (When applicable: Steel to only •S, plastic plate only (Table 3) Density /ft2 ). EnergyGuardTM, EnergyGu + TM Composite, EverGuard® ISO, 'EnergyGuardTM RA, EnergyGuardTM RA Compost Minimum 1" thick N /A N/A EnergyGuardTM High Density W + od Fiber, EnergyGuardTM Recover Board, Wood Fiber, Minimum %z" thick N/A N/A EnergyGuardTM Perlite Minimum 3/4" thick Fiberglas (Min. 15/16" thick) Note: All insulation shall be adhered to th within the EVT range and at a rate of 20- Standard RAS 117 for insulation attachment. as base layers with a second layer of approved substrate. Composite insulation panels may be polyisocyanurate side facing down. GAF requir EliminatorTM Perforated laid dry or a layer of En on all isocyanurate applications. N/A N/A N/A • N/A anchor sheet in full mopping of approved hot asphalt bs/100 ft2. Please refer to Roofing Application Insulation listed as base layer only shall be used only p layer insulation installed as the final membrane ed as a top layer placed with the either a ply of GAFGLAS® STRATAVENT® GuardTM Perlite or wood fiber overlay board Fire Barrier: (optional) Anchor sheet: FireOutTM Fire Barrier Coating, Underlayment or SecurockTM. GAFGLAS® #80 ULTIMATM Base Nailable, RUBEROID® Modified Ba Heat- WeldTM Smooth or RUBEROID fastened as described below; rsaShield® Non-Asphaltic Fiberglass -Based eet, STRATAVENT® EliminatorTM Sheet, RUBEROID® 20, RUBEROID eat- WeIdTM 25 base sheet mechanically Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex Ply 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to dec with approved annular ring shank nails and tin caps at a fastener spacing of 9" ► .c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See Gen ' al Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 8 of 19 Fastening Options: Base Sheet Ply Sheet: MINI DADECOUNTY APPROVED GAFGLAS® PIy 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 2" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally s aced approximately 12" o.c. in the field of the sheet. um Design Pressure —45 psf, See General Limitation #7) •G `' LAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor shoe attached to deck with approved annular ring shank nails and tin caps at a . fasten-` spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maxim' .Design Pressure --52.5 psf, See General Limitation #7) GAFGLAS'' #80ULTIMATM, RUBEROID®20, RUBEROID®Mop Smooth, base sheet attache to deck with approved 11/4" annular ring shank nails and inverted 3" steel plate a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with =,fastener spacing of 9" o.c. in the center of the membrane. (Maximum Desi? Pressure —64 psf, See General Limitation #7) GAFGLAS® #75 B': - Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 stan : d, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac "Iates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equ, spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Press e --60 psf, See General Limitation #7) Any of above Anchor sheets ttached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" 'n the field. (Maximum Design Pressure —6 i` , sf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any . f above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 1 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. i4 rows. One row is in the 2" side lap. The other rows are equally spaced appr +,. imately 9" o.c. in the field of the sheet. (Maximum Design Pressure —7S psf, Se - General Limitation #7) (Optional) Install one ply of GAFGLAS® #`� , GAFGLAS® #80 ULTIMATM Base Sheet, GAFGLAS® STRATAVENT® \ iminatorTM Perforated, RU BEROID® Modified Base Sheet, RUBER I f ® Mop Smooth, RUBEROID® 20 RUBEROID® Heat- WeIdTM Smooth or RUBS, ROID® Heat- WeldTM directly over the top layer of insulation. Adhere with an \ pproved mopping asphalt applied within the EVT range and at a rate of 20-4' bs.Isq; (see General Limitation #4). One or more plies GAFGLAS® PLY 4, GAFGLAS®" ex P1yTM 6 sheet, #80 Ultima, RUBEROID® Mop Smooth or RUBEROID® 2 adhered in a full mopping of approved asphalt applied within the EVT ge and at a rate of 20 -40 Ibs.sq. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 . Approval Date: 03/20/08 Page 9 of 19 Cap Sheet: • (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or AFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full m ping of approved asphalt applied within the EVT range and at a rate of 20- 0lbs.sq. Surfacing: (Optio I, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membran- Install one of the following: 1. : vel or slag applied at 400 lbs. /sq. and 300lbs. /sq. respectively in a ood coat of approved asphalt at 60 Ibs.sq. or applied in a flood coa of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a r:: a of 3 gal./sq. 2. GAFGL S® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral S faced Capsheet adhered in a full mopping of approved asphalt appl - d within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterTM r atrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 ga sq. 4. Leak BusterTM Matri TM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TO COAT® Fireshield Elastomeric Roofing Membrane, applied at 1 t+ 1.5 gal. /sq. Maximum Design Pressure: MAMI.DAb _ _ 0 TY APPROVED 5. Leak BusterTM MatrixTM 6 ' B Xtra Elastomeric Roofing Membrane, EnergyCote® roo oating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOP • AT® Fireshield® SB Solvent based Elastomeric Roofing Membr :. e applied at Ito 1.5 gal. /sq 7. Advance Green Technologies Photo oltaic Laminate solar energy collector auxiliary roof equipment in F: led in compliance with manufacturer's specifications and applicab Building Codes. See Fastening above. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 10 of 19 Deck Type I: Wood, Insulated Deck Descrip on: 19/32" or greater plywood or wood plank System Type B: All General and Sys One or more layers of Insulation for Base Lay When applicable: Steel p EnergyGuardTM, EnergyG Minimum 13" thick EnergyGuardTM RN Minimum 1.4" thick Optional base sheet laid dry; base layer of insulation mechanically optional top layer adhered with approved asphalt. m Limitations shall apply. of the following insulations. (Table 2) to only =S, plastic plate only =P rdTM RA EnergyGuardTM Composite, Energy , uardTM RA Composite Minimum 1.5 thick EnergyGuardTM Perlite Minimum /" thick fastened, Insulation Fasteners Fastener (Table 3) Density/ft2 1:3 ft2 1,2,or3 1,2,or3 3 1:3ft2 1:3 ft2 1S(3.5 "),or3 1:2 ft2 ' EnergyGuardTM Fiberboard, EnergyGuardTM ` ; gh Density Fiberboard Minimum 1" thick 1,2,or3 1:4ft2 Note: Base layer shall be mechanically attached wi fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if lar er panels are used the number of fasteners per board shall be increased maintaining the same faste er density (See Roofing Application Standard RAS 117 for fastening details). GAF requires e er a ply of GAFGLASn STRATAVENT® EIiminatorTM perforated laid dry or a lay of EnergyGuardTM or wood fiber overlay board on all isocyanurate applications. Insulation for Top Layer (Table 2) sulation Fasteners When applicable: Steel plate only =S, plastic plate only =P (Table 3) Any of the insulations listed for Base Layer, above. N/A Fastener Density/ft2 N/A EnergyGuardTM High Density Wood Fiber, EnergyGuardTM High D sity Wood Fiberboard, EnergyGuardTM Recover Board Minimum 'A" thick ,\ /A N/A Note: Optional top layer of insulation shall be adhered with approved as + , alt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Applicatio Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall installed with the polyisocyanurate face down. Fire Barrier: (optional) •.•DE *. NTY' APPROVED FireOutTM Fire Barrier Coating, VersaShiele Non - Asphaltic Fiberglass -Based Underlayment or SecurockTM. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 11 of 19 Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMAT' Base Sheet, GAFGLAS® PLY 4, GAFGLAS® Flex PI 31rm 6, GAFGLAS® STRATAVENT® Eliminator Perforated(laid dry), RUBEROID® Modified Base Sheet, RUBEROID® Mop Smooth or RUBEROID ® 20 directly over the top layer of 1 sulation. Adhere with any approved mopping asphalt applied within the EVT ge and at a rate of 20 -40 lbs. /sq; (see General Limitation #4). Ply Sheet: T or more plies of GAFGLAS® PLY 4, GAFGLAS® FlexPly'm 6 ply sheet, #80 Ulti a, RUBEROID® Mop Smooth or RUBEROID® 20 adhered in a full mopping of appr ed asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (See speci i' ation number for appropriate number of plies). Cap Sheet: (Option:) ®EnergyCapTM ply of GAFGLAS''' Mineral Surfaced Cap Sheet or GAFGLA EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping o approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq,(See GAF application instructions for approved method of installation). Surfacing: (Optional, requir if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install o ;e of the following: 1. Gravel or °• ag applied at 400 lbs./sq. and 300 lbs. /sq. respectively in a flood coat o approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak Buster MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Min, al Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced . sheet adhered in a full mopping of approved asphalt applied withi the EVT range and at a rate of 20 -40 lbs./sq. 3. Leak BusterTM Matrix 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 71' ,LeakBusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOA 'i Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 _ :. /sq. 5. Leak BusterTM MatrixTM 602 MB tra Elastomeric Roofing Membrane, EnergyCote® roof coating applied 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOA Fireshield® SB Solvent based Elastomeric Roofing Membrane applie at lto 1.5 gal, /sq 7. Advance Green Technologies Photov•,talc Laminate solar energy collector auxiliary roof equipment in led in compliance with manufacturer's specifications and applicabl , uilding•Codes. Maxiinunj Design Pressure: -45 psf; (See General Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 12 of 19 Deck Type 1I: Wood, Insulated Deck Descrip : on: 19/"' • 32 or greater plywood or wood plank System Type C: One or more layers of insulation simultaneously attached; Base layer optional. All General and ; tem Limitations shall apply. One or more layers of y of the following insulations. Insulation for Base Lay', (Table 2) Insulation Fasteners Fastener (When applicable: Steel p to only =S, platic plate only =P) (Table 3) Density /ft2 EnergyGuardTM RN, Energ GuardrM, EnergyGuardTM RA Minimum 1.3" thick EnergyGuardTM Min. 1.4" thick EnergyGuardTM Composite, Ener uardTM RA Composite Minimum 1.5" thick EnergyGuardTM Perlite Minimum %" thick N/A N/A N/A N/A Wood Fiber, EnergyGuardTM Fiberboard, ergyGuardTM High Density Fiberboard Minimum 1" thick N/A Note: All layers shall be simultaneously faste Insulation panels listed are minimum sizes and of fasteners shall be increased maintaining the Application Standard RAS 117 ' for insulation GAFGLAS® STRATAVENT® EliminatorTM perfo Perlite or wood fiber overlay board on all isocyanurat N/A N/A N/A • N/A N/A ed; see top layer below for fasteners and density. imensions; if larger panels are used, the number me fastener density. Please refer to Roofing ttachment. GAF requires either a ply of ted laid dry or a layer of EnergyGuardTM applications. Insulation for Top Layer (Table 2) When applicable: Steel plate only =5, plastic plate only =P EnergyGuard, EnergyGuard RA Minimum 1.3" thick EnergyGuardTM RN Minimum 1.4" thick Insulation Fasteners (Table 3) 1,2,or3 1,2,or3 EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5 thick EnergyGuardTM Perlite Minimum %" thick Fiberglas Minimum 15/16" thick 1, 2, or 3 Wood Fiber, EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberb ard Minimum 1" thick 1, 2, or 3 1S(3.5' . or3 IAJ%DADE • UNIT APPROVED Fastener Density /ft2 1:3 ft2 1 :3 ft2 1:3 ft2 1:2 ft2 1 :2.67 ft2 1:4 ft2 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 13 of 19 Note: Insulation panels listed are minimum sizes and dimensions; if Iarger panels are used, the number of fa eners shall be increased maintaining the same fastener density. Please refer to Roofing AppIica on Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® 5 ' TAVENT® EIiminatorTM Perforated laid dry or a layer of EnergyGuardrM Perlite or wood fibe overlay board on all isocyanurate applications. Fire Barrier: F. OutTM Fire Barrier Coating, VersaShield®Non- Asphaltic Fiberglass -Based (optional) Un - rlayment or SecurockTM. Base Sheet: (Optic al) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA'"' Base Sheet, a GLAS® PLY 4, GAFGLAS FIexPIyT' 6, GAFGLAS® STRATAVENT® Eliminate TM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBERO '►® Mop Smooth or RUBEROID® 20 directly over the top layer of insulation. ere with any approved mopping asphalt applied within the EVT range and at a ate of 20- 401bs. /sq.. If base sheet is applied.directly to polyisocyanura insulation only a spot or strip mopped application as detailed in this approval the se of an overlay-board is approved; see General Limitation #4. Ply Sheet: Two or more plies • GAFGLAS® PLY 4, GAFGLAS® FlexPly' 6 ply sheet, #80 ULTIMATM, , RUBE'. OID Mop Smooth or RUBEROID® 20 adhered in a full mopping of approved > phalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. Cap Sheet: (Optional) One ply of GA GLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM Mineral Su -d Cap Sheet adhered in a full mopping of approved asphalt applied within the E " range and at a rate of 20 -40 lbssq. Surfacing: (Optional, required if RUB ' OID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the fo owing: 1. Gravel or slag appli- at 400 lbs.sq. and 300 lbs. /sq. respectively in a flood coat of approve • ` ; phalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM Matri TM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfs ' ed Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet a ered in a full mopping of approved asphalt applied within the EV range and at a rate of 20- 40lbs. /sq. 3. Leak BusterTM MatrixTM 303 P -mium Fibered Aluminum Roof Coating, at 1.5 galJsq. 4. Leak BusterTM MatrixTM 715 , L- : : usterTM MatrixTM - 322, TOPCOAT® MB +, TOPCOAT® Fire , hield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra astomeric Roofmg Membrane, EnergyCote+1/ roof coating ap ' lied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fire shield® SB Solvent based Elastomeric Roofing Membrane applied at 1 1.5 gal.isq 7. Advance Green Technologies Photovoltaic inate solar energy collector auxiliary roof equipment installer in compliance with manufacturer's specifications and applicable Bui `, ing Codes. Maximum Design Pressure: -45 psf; (See General Limitation #7) MlAMb * ! E • UNTIE APPROVED NO No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 14 of 19 Deck Type 1I: Deck Description: Wood, Insulated 19/32" or greater plywood.or wood plank System Type D: Insulation and Base sheet simultaneously All General and S tem Limitations shall apply. One or more layers o y of the following insulations. Insulation Layer loos ?,,y laid with firmly butted joints. Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM, Ener uardTM RA, Minimum 1.3" thick N/A N/A EnergyGuardTM High Densi ,a Fiberboard, EnergyGuardTM Fiberboard Minimum 1" thick N/A N/A Fire Barrier: FlreOutTM ' ., ire Barrier Coating, VersaShield® Non- Asphaltic Fiberglass -Based (optional) Underlayme, t or SecurockTM. Base Sheet: Install one ply `•f GAFGLAS® #75, GAFGLAS® #80 Ultima ULTIMA' Base Sheet, GAFGL ® STRATAVENT® EliminatorTM Nailable or RUBEROID® 20 base sheet a . ; ed over the loose laid insulation with 2" side laps mechanically faste '. ed as described below; Fastening Options: Drill-TecTM #12 s lard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-TecTM AccuTra . ' lates are installed through the base sheet and insulation in 3 rows 12" o.c. One ro is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. i the field of the sheet. (Maximum Design Press e —45 psf, See General Limitation #7) Drill-TecTM #12 standard, #f � , or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates installed through the base sheet and insulation in 4 rows 8" o.c. One row is in th ', " side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field f the sheet. (Maximum Design Pressure —75 p' , See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBE I ID ®20, RUBEROID® Mop Smooth, base . sheet attached to deck with approved : ular ring shank nails with a minimum embedment of I" into the wood substrate d inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two r� ws staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See Ge `: ral Limitation #7) Drill -TecTM #12 standard, #14 or # 15 Screws an 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates in 4 rows 12" o.c. O ,.e row is in the 2" side lap. The other rows are equally spaced approximately 9' .c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General L ' Italian #7}. Ply Sheet: One or more plies GAFGLAS® PLY 4, GAFGLAS ®, G ' GLAS® F1exP1yTM 6 sheet, #80 Ultima or RUBEROID® 20adhered in a full mop ing of approved asphalt applied within the EVT range and at a rate of 20- 401 +sisq. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 15 of 19 Cap Sheet: Surfacing: Maximum Design Pressure: See Fastening Above (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (Op+'onal, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top mem' ' rane) Install one of the following: 1. Gravel or slag applied at 400 lbs, /sq. and 300 lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied t a rate of 3 gal. /sq. 2. G FGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Min al Surfaced Capsheet adhered in a full mopping of approved asph applied within the EVT range and at a rate of 20 -40 lbsisq. 3. Leak•Bu. erTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, a 1.5 gal. /sq. 4. Leak Buster MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® +, TOPCOAT® Fireshield Elastomeric Roofmg Membrane, apple- • at 1 to 1.5 galisq. 5. Leak BusterT' Matr TM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCo •,,, roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, OPCOA'I Fireshield® SB Solvent based Elastomeric Roofing ! embrane applied at Ito 1.5 gallsq 7. Advance Green Technologies ' hotovoltaic Laminate solar energy collector auxiliary roof equip nt installed in compliance with manufacturer's specifications and applicable Building Codes. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 16 of 19 Deck Type 1: Deck Description: Wood, Non- insulated 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: (optional) Base sheet: FireOutTM Fire Barrier Coating, Versa Shield® Non-Asphaltic Fiberglass -Based Underlayment or SecurockTM, GAFGLAS® #80 ULTTMATM Base Sheet, STRATAVENTo EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® Heat- We1dTM Smooth or RUBEROID® Heat- WeIdTM 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure --45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS ® -Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID ®20, RUBEROID®Mop Smooth, base sheet attached to deck with approved 1114" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure --60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psi, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and:3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure --60 psf, See General Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 17 of 19 Ply Sheet: Cap Sheet: Surfacing: GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) One or more plies of GAFGLAS® PLY 4, #80 ULTIMA, RUBEROID® MOP Smooth or RUBEROID'" 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (Optional) One ply of GAFGLAS Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400lbs. /sq. and 300 Ibsisq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galisq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote+D roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal. /sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07- 1219.09 Expiration Date: 11/04113 Approval Date: 03/20/08 Page 18 of 19 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex PIyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum ' " Dens DeckTM or %z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 Ibs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor /base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and /or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI ' ' E OU TY APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 19 of 19