RF-12-1137Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 175022
Permit Number: RF -6 -12 -1137
Scheduled Inspection Date: August 22, 2012
Inspector: Bruhn, Norman
Owner: MESSANA, STEPHANIE
Job Address: 149 NE 107 Street
Miami Shores, FL 33161 -7031
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Repair Roof
Phone Number
Parcel Number 1121360070290
Phone: (305)953 -3333
Building Department Comments
REPAIR LEAK AT REAR FLASHING, OF TILE ROOF.
PAINT FLAT ROOF WITH A UNIFORM COATING OF
ALUMINUM ROOF PAINT
Pass
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
August 22, 2012
For Inspections please call: (305)762 -4949
Page 10 of 38
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
BIIILD G��
PERMIT APPLICATION
Permit Type: BUILDING
JOB ADDRESS: 149 N.E. 107 Street
City:
Folio/Parcel #:
Permit No.
FOMWM--
la JUN 2 26;2 g
0
BY:. .. ® ®o ® ®o ®o
FBC 20
Master Permit No.
EZOOFING
Miami Shores County:
11- 2136- 007 -0290
Miami Dade
Zip: Zip: 3 31 61
Is the Building Historically Designated: Yes
NO X
Flood Zone:
OWNER: Name (Fee Simple Titleholder): Stephanie Messana Phone#: (305) 785-5811
Address: 149 N.E. 107 Street
City: Miami Shores State: Fl Zip: 33161
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name:Quality Roofing Contractor, Inc .Phone#: (305) 953 -3333
Address: 13800 N. W. 1st Avenue
City: Miami
Qualifier Name: Carlos Arocho
State Certification or Registration #: RC 0058627 Certificate of Competency #: 0 0 0 017889
Contact Phone #: (305) 953 -3333 Email Address: qualityroofing88 @yahoo.com
DESIGNER: Architect/Engineer: Phone#:
State: Florida
Zip: 33168
Phone #: (786) 367 -2029
Value of Work for this Permit: $ $3,500.00 Square/Linear Footage of Work: 1 / 2 sqf t .
Type of Work: DAddition ❑Alteration
UNew X Repair/Replace
Description of Work: Repair leak at rear flashing, of tile roof.
ODemolition
Paint flat roof with a uniform coating of aluminum
paint.
roof
Color thru tile:
********* ********** * * ** **** ***** * *** ***F s ******** ** * * ******* **** ** * ** *** * * ******
Submittal Fee $ Permit Fee $ 40 CCF $ CO /CC $
Sc pning Fee $ Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for 1 T.RCTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S A} ll)AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Owner or Agent
The foregoing instrument was acknowledged before me this r2®
day of , 201, by ,
who is personall own to me or who has produced
As identification and who did take an oath. =
NOTARY PUBLIC:
Sign:
Print:
NOTARY PUBLIC -STATE OF FLORIDA
My Commission Exp. " "' '''' ' Marylou Hernandez
Commission #DD930046
ems- ••:
Expires: OCT. 10, 2013
BONDED THU ATLA.\ -TIC BONDING CO., INC.
Contractor
The foregoing instrument was acknowledged before me this
day of 5 t� , 201a--, by
,
who is personally known to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
NOTARY PUBLIC -STA`. 1F FLORIDA
My Commission Expipsh,,, Marylou t' '°'nandez
Commissic 1.-% 3930046
Expires: . 10, 2013
***+k*+k****#* kWab*+b+k*** kW*+ k**+ k**********4**N +kM'" °' ne4nsn mRJ ATI A5T __ ,.,_ cap
APPROVED BY
Plans Examiner Zoning
Structural Review Clerk
(Revised 3 /12/2012)(Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09)
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
JUN 2 2 6 2
Master Permit No.
Contractor's Name
Job Address 149
Florida Building Code
High Verity Hurricane Zone Uniform P
Section A General I
Process No.
Quality Roofing Contractor, Inc.
N.E. 107 Street
❑ Low Slope
❑ Asphaltic Shingles
❑ New Roof ❑ Reroofing
Sketch
include
parapets.
ROOF CATEGORY
❑ Mechanical!
❑ Metal Panel/Shingles
❑ Prescriptive BUR -RAS 150
ROOF TYPE
❑ Recovering
ROOF SYSTEM
INFORMATION
❑ Mortar /Adhesive Set Tile
❑ Wood ShingleslShakes
Repair ❑ Maintenance
rea (SF) Steep Sloped Roof Area (SF)
1/2sg. Total (SF) 1 /2sq.
Section B (Roof Plan)
Is and sections, roof drains, scuppers, overflow scuppers and overflow drains.
d levels, clearly identify dimensions of.elevated pressure zones and location of
K
1
al
S
1
15.34 2010 FLORIDA BUILDING CODE — BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
High - Velocity Hurricane Zone Uniform Permit Application Form.
Section D tee • Slo • ed Roof S stem
Existing Tile Roof_
Roof System Manufacturer: Clay Forever, LLC
Notice of Acceptance Number: 07 -091 9.05
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations):
1: N/A P2: N/A P3: N/A
Roof Slope:
3 : 12
Steep Sloped Roof System Description
Deck Type:
wood1 X 6
Type Underlayment:
Ridge VentilationA
Insulation:
(1) 301b.
N/A
Fire Barrier:
Mean Roof Height:
13'
N/A
Fastener Type & Spacing:
Adhesive Type:
1 1/4" R/S nails
Type 1V asphalt
Type Cap Sheet:
901b.
Roof Covering:
Spanish S Clay tile
Type & Size
Drip Edge:
3 X 3 26ga.
galv.
15.36 2010 FLORIDA BUILDING CODE — BUILDING
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govem the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1. Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providin that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system).
3. 5 Common roofs: Common roofs are those which have no visible delineation between neighboring
units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or
owner should notify the occupants of adjacent units of roofing to be performed.
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appearance.
5. - Ponding water: The current roof system and /or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of the
roof.
�1� it G- /t - /t-
Own r /Agent's Signature Date Contractor Signature
Revised on 7/9/2009 LD
Date
M1AMIDADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Clay Forever, LLC
6801 NW 77th Avenue
Miami, FL 33166
MIAMI -DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375 -2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Altusa "S" Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA #06 -0706.09 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category:
Sub - Category:
Material:
Roofing
Roofing Tiles
Clay
1. SCOPE
This renews roofing system using Altusa One Piece S' Clay Roof Tiles, as manufactured by
Alfareria Del Turbio, S.A. (ALTUSA) in Venezuela and described in Section 2 of this Notice of
Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be done as a
moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Altusa One Piece `S'
Tile
Trim Pieces
Clip
Clip
Dimensions
L= 181/4"
W = 10.5"
1/2" thick nominal
3.25" high
Length: varies
Width: varies
varying thickness
L = 6"
D = 0.125"
L &h = 2"
W =1/2"
0.05" thick
2.1 SUBMITTED EVIDENCE:
Test Agency
IBA Consultants, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation Testing
Test
Spec'if'ications
TAS 112
TAS 112
TAS 114
TAS 114
Test Identifier
2397 -116
94 -083
94 -084
25- 7200 -1
Project No. 307025
Test #MDC -78
MTS 520649
Product
Description
High profile clay roof tile. For direct deck or
batten nail -on, mortar set or adhesive set
applications with minimal headlap of 2 -Y2"
Accessory trim, clay roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Tile clip
L Shaped tile clip
Test Name/Report Date
06/28/07
April 1994
May 1994
Feb. 1995
Oct. 1994
TAS 102(A) May 2000
NOA No.: 07- 0919.05
Expiration Date: 12116/12
Approval Date: 12/20/07
Page 2 of 7
ASTM C 1167
Static Uplift Testing
TAS 101 (Adhesive Set)
Static Uplift Testing
TAS 101 (Mortar Set)
Static Uplift Testing
TAS 102
(Quick-Drive Screws,
Battens)
Wind Driven Rain •
TAS 100
Test Agency
PRI Asphalt Technology, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
3. LIMITATIONS
Test Identifier
CLF- 003 -02-01
7161 -03; Appendix III
7161 -03
Appendix II
Letter Dated Aug. 1,
1994
P0631 -01
P0402
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Test Name/Report
TAS 102
TAS 102
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Aerodynamic Multiplier
25 -7183
25 -7094
25 -7496
25 -7584
25- 7804b -8
25-7804-4 & 5
25- 7848 -6
Date
October 2001
Dec. 1991
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
March 1999
March 1995
February 1996
April 1996
December 1996
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with RAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications Minimum deck requirements shall be in
compliance with applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 'Altusa One Piece S' Clay Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
NOA No.: 07- 0919.05
Expiration Date: 12116/12
Approval Date: 12/20/07
Page 3 of 7
Table 1: Average Weight (W) and Dimensions (ix w )
Tile Profile
Weight- W.(Ibf)
Length -1(ft)
Width -w (ft)
Altusa 'S' Tile
6.9
1.52
0.875
Table 3: Restoring Moments due to Gravity - Ma (ft-Ibf
Tile
Profile
Table 2: Aerodynamic Multipliers - X (ft3)
4 ": 12"
Tile
6 ": 12"
X (ft)
X (ft3)
Battens
Profile
Battens
Batten Application
Direct Deck Application
Altusa 'S' Tile
Battens
Direct
Deck
0.253
0.274
Table 3: Restoring Moments due to Gravity - Ma (ft-Ibf
Tile
Profile
3 ": 12"
or less
4 ": 12"
5 ": 12"
6 ": 12"
7 ": 12" or
greater
Altusa 'S' Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
4.47
5.35
4.40
5.27
4.31
5.16
4.20
5.03
4.08
4.89
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft -Ibf
for Nall-On Systems
Tile
Profile
Fastener Type
Direct Deck
(Min 15/32"
plywood)
Direct Deck
(Min. 19/32"
plywood)
Battens
Altusa 'S' Tile
2 -10d Ring Shank Nails
28.6
41.2
19.4
1 -10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2 -10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 . #8 Screw
28.7
28.7
N/A
2 . #8 Screws
58.2
58.2
26.8
1 -10d Smooth or Screw
Shank Nail (Field Clip)
23.1
23.1
19.0
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
29.3
29.3
24.0
2 -10d Smooth or Screw
Shank Nails (Field Clip)
27.6
27.6
38.6
2 -10d Smooth or Screw
Shank Nails (Eave Clip)
38.1
38.1
41.8
1 Screw with Altusa Clip (See c
ip details)
Altusa "S"
Tile'
1 Screw with clip (at the
head of tile)
187.1
187.1
N/A
Altusa "S"
Tile'
1 Screw with clip (at the
water course of tile)
35.2
35.2
N/A
1. Screw must be installed in the inside nail hole located nearest to the hump of the tile.
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table 6: Attachment Resistance Expressed as a Moment Mt (ft Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Altusa 'S' Tile
Adhesive
29.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 10.7 grams.
Polyfoam Product, Inc. Average weight per patty 8 grams.
4 Large paddy placement of 63 grams of PoIyProTM.
Table 7: Attachment Resistance Expressed as a Moment - Mir (ft Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Altusa 'S' Tile
Polyfoam PolyProTM
66.54
Polyfoam PolyProTM
3875
4 Large paddy placement of 63 grams of PoIyProTM.
5 Medium paddy placement of 24 grams of PolyProm'.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or
following statement: "Miami -Dade County Product Control Approved ".
* * * aLnUSa MADE IN VENEZUELA
IDENTIFICATION MARK FOR ALTUSA `S' CLAY ROOF TILE
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building
code in order to properly evaluate the installation of this system.
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 5 of 7
Table 8: Attachment Resistance Expressed as a Moment - Mt (ft-ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Azusa `
S Tile
Mortar Set'
24.50
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or
following statement: "Miami -Dade County Product Control Approved ".
* * * aLnUSa MADE IN VENEZUELA
IDENTIFICATION MARK FOR ALTUSA `S' CLAY ROOF TILE
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building
code in order to properly evaluate the installation of this system.
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 5 of 7
PROFILE DRAWINGS
ALTUSA `S' CLAY ROOF TILE
°SPANISH S°
TILE BY ALTO
(TYP.)
CLIP DETAILS
2 -1/2° OVERLAP
(COVERS PIN HOLE)
SCREW IN THE INSIDE HOLE
NEAREST TO THE HUMP OF THE TILE
DECK
CLIP WITH ONE (1) SCREW
ATTACHED TO DECK
CUP PLACEMENT DETAIL
CUP
NOA No.: 07 -0919.05
Expiration Date: 12/16/12
Approval Date: 12120/07
Page 6 of 7
SCREW (HOLDS
CLIP ONTO DECK)
°SPANISH S°
TILE BY ALTUSA
CLIP DETAILS (CON'T)
2112° OVERLAP
(COVERS PIN
HOLE)
SCREW IN THE INSIDE NAIL HOLE
NEAREST TO THE HUMP OF THE TILE
DECK
1 1/4° 1 3/4° 3/4°
CUP PLACEMENT DETAIL
3.00°
GALVANIZED
METAL CUP
DECK
END OF THIS ACCEPTANCE
21/2° SCREW
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 7 of 7
NOTICE OF COMMENCEMENT
• A RECORDED DOPY MUST BE POSTED ON THE JOB SITE ATTIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO.1 1 -21 36- 007 -0290
STATE OF FLORIDA-.
COUNTY OF MIAMI -DADE:
STAMEOFFUNR
r �r�v
THE UNDERSIGNED hereby gives notice that improvements will be made %t�Fr��a v c��rea,
property, and in accordance with Chapter 713, Florida Statutes, the following information
is provided in this Notice of Commencement.
111111111111111111111111111111111111111111111
b 117,65'
HARV r RvV , CLE
BY
1. Legal description of property and street/address: 1 4 9 N .E . 10 7 Street
Miami Shores, F1 33161
CFH 20 12Rri4 56520
OR Bk 28167 F's 2068; (lps)
RECORDED 06/28,/2012 09:24:38
HARVEY RUVINy CLERK OF COURT
MIAMI—DADE COUNTYr FLORIDA
oadqvagE
,yam the
_Also ety of
2. Description of improvement* Repair leak at rear flashing of tile roof.
• 3. Owner(s) name and address Stephanie Messana
149 N.E. 107 Street Miami Shores, Fl 33161
Interest in property Owner
Name and address of fee simple titleholder. N/A
4. Contractor's name and address.. Quality Roofing Contractor,
13800 N.W. 1st Avenue
5. Surety: (Payment bond required by owner from contractor, if any)
Name and address: N/A
Amount of bond $ 0
6. Lender's name and address: N/A .
Inc.
Miami., Florida 33168
7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as
provided by Section .713.13(1)(a)7., Florida Statutes,
Name and address: N/A
8. In addition to himself, Owners designates the following persorgs)'to receive a copy of the Lienor's Notice as provided
in Section 713.13(1)(b), Florida Statutes.
Name and address- N/A
9. Expiration date of this Notice of Commencement (the expiration date is 1 year from the date of recording unless a
different date is sp cified)
�r I
Sign - / re of Owner
Print Owner's Name 10 eW2/ me6'sema/
Sworn to and subscribed before me this .9-D ay of 1 --
Notary Public
Print Notary's Name
My commission expires:
• 123.01-52 PAGE 4 10/04
DT(1TARV PTTBT TC.STATR OF FT.ORTT1
Marylou Hernande
ommissiuu M9301,46
Prepared by Marylou Hernandez
,.20 /2. Quality Roofing Cont., In
Address 3800 N.W. 1st Ave
Miami, Florida °33168
(305) 953 -3333
,.„ Expires: OCT.10, 2013
BONDED TfiRU ATLANTIC B05DLN1G CO., NC.