MC-12-1561Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 177493 Permit Number: MC -8 -12 -1561 Scheduled Inspection Date: September 05, 2012 Inspector: Perez, JanPierre Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Browne Hall Miami Shores, FL 33138 -0000 Project: BARRY UNIVERSITY Contractor: HILL YORK SERVICE CORP Permit Type: Mechanical - Commercial Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1121360010160 -14 Phone: (305)756 -6501 Building Department Comments INSTALL 3 UNITS 1.5 TON EACH l Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. September 04, 2012 For Inspections please call: (305)762 -4949 Page 17 of 33 • Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: MECHANICAL /L/ o� �� , �� JOB ADDRESS: N CJ Z' e A I6 City: Miami Shores County: Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: FBC �,r� n Permit No. ► 1 C 12 -1 Sk 1 Master Permit No. ograi, Miami Dade Zip: 33'CK, OWNER: Name (Fee Simple Titleholder): l.,Y n lV.LV?3I.� "f (0 Phone #: Address: I I � X J) 14 2nd i- City: i) pm a Shur) ' State: �4 Zip: 3�I(9 Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company Name: /4-i I I Y1)rlL Address: (9, a5 5 , -r d rJIL)S Ai.-Q- City: 1-J ktui'/ G�Q &� state: ,�� Qualifier Name: � OWL, k'i 0 c�a0 Phone #: Zip:IL Phone#: State Certification or Registration #: pl "I lJJ //nn Certificate oof Competency #: OEM � 3- 3q (U,"1 Contact Phone #: Email Address: NW2 eh l 1'k'QOL . DESIGNER: Architect/Engineer: / Phone #: Value of Work for this Permit: $ !) Square/Linear Footage of Work: Type of Work: ]Address ]Alteration New [ Repair/Replace ]Demolition Description of Work: flOV IO 4 4 t, kilo& J r-47JAIftlircAril f& ******** * *** * ** ********** ** ** * *** ****** es+x �x�x�x+ x*: xx��x**** �x* �x�x+ x *�x�x*** *** * *x:�x *+x:x�x *x�*** Submittal Fee $ �, n„ _',/M.. Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ �- r 4 • Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOB .FRS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this 1 day of kAUA , 20 It; by atitA (( `e it I o , who is personally known to a or who has produced As identification and who did take an oath. Sign: Print: My Commission Expir ***** ** * * * * * * ********* **** * * ** * * * * ** **** APPROVED BY Signature � yr Contractor Mart, y �� The foregoing instrument was acknowledged before me this i 9-N h day of L ,,� , 20 I� , by it , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Plans Examiner Structural Review Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Sign: Print: CASTRO My Commis , stilY COMMISSION # EE109306 • EXPIRES August 07, 2015 •¢i ' ` eNorary$ervicesmat (407) 398-0153 Zoning Clerk Ammi RUUD Design Star Load Calculation Results are intended for use with Ruud heating and cooling systems only Customer Information Location: Street Address 11300 NE 2nd Ave, MIAMI-DADE, FL 33161 Latitude, Longitude 25.7791°, -80.1978° House Square Footage: 572 sq. ft. Name: Barry U - Browne Hall Rms 25/26 Phone: 123-123-1234 Email: example@maiLcom Desi n Conditions Outdoor Heating Cooling Dry bulb (°F) 54 92 Daily range L Relative humidity 50% Moisture difference Indoor Indoor temperature (°F) Design temperature difference(°F) 58 Heating Cooling 68 74 14 18 Hea]i�� '' Loads Area Btuh % of load Wall 7480 45 Floor 8453 50.9 Ceiling �' 424 2.6 Windows 252 1.5 / Infiltration 0 0 ---------------------`-------^-~--` System Efficiency Loss 0 0 --_._--'_------------'_'-_-_-_-_---__-_-_ Total: I66I0 Floor Heati ng Loads 16 .610 eTuyh, Infiltration System Efficiency Loss Windows Ceiling Wall Coolin. Loads Area Wall Ceiling Windows Sensible Infiltration ................... ............ ............................... Latent Infiltration Btuh % of load .......... ............................... 59.5 9617 546 3.4 2008 12.4 948 5.9 1888 11.7 System Efficiency Gain 0 Internal 642 Sensible People Load Latent People Load 263 Total: Sensible load Latent load SHR Capacity at .87 SHR Cooling Loads 16,175 BTU /hr r System Efficiency Gain Sensible People Load I 1 � —Ltent People Load 111 �eiling Internal / — Sensible Infiltration Latent Infiltration Wall 3000 2000 � � 1000 o AED Graph 8am ovm zoam zzvm ovm lpm 2pm 3pm [ Manual "^~ ^~"x°' System equipment selection will be made using the following Manual derived values. Summer Outdoor 92°F Summer Wet BuIb 77°F Summer Indoor 74°F Summer Design Grains 50% Winter Outdoor 54°F Winter Indoor - 68°F Sensible Cooling 14,023 Btuh _-_'--_-_--_-__---_'-__--_----___--__----_ __ Latent Cooling 2,151 Btuh Required Cooling Airflow 637 CFM Sensible Heating 16,610 Btuh Required Heaing Airflow 216 CFM An calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. fII computed results are Estimates, Product provided by Energy Design Systems and Idea Tree iiu RUUD DesignStar Load Calculation Results are intended for use with Ruud heating and cooling systems only Customer Information Street Address Latitude, Longitude House Square Footage: Name: Email: Location: 11300 NE 2nd Ave, MIAMI -DADE, FL 33161 25.7791 °, - 80.1978° 572 sq. ft. Barry U - Browne Hall Rms 31/32 123 -123 -1234 example @mail.com Desi• n Conditions Dry bulb (°F) Daily range Relative humidity Moisture difference Outdoor Cooling L Indoor Indoor temperature ( °F) 58 Heating Cooling Design temperature difference( °F) 14 18 Heatin• Loads Wall Floor Ceiling Windows Area Infiltration Btuh % of load 7480 45 8453 50.9 424 2.6 252 1.5 System Efficiency Loss 0 Total Floor 0 Heating Loads 16,610 BTUThr Infiltration System Efficiency Loss Windows Ceiling Wall Coolin• Loads: Area Wall Ceiling Windows Sensible Infiltration Btuh % of load 9617 59.5 546 3.4 2008 12.4 948 5.9 Latent Infiltration 1888 11.7 System Efficiency Gain Internal Sensible People Load Latent People Load Total: Sensib Latent Load SHR load 2151 0.87 Capacity at .87 SHR 1.34 Tons Cooling Loads 16175 BTU /hr System Efficiency Gain Sensible People Load ad Lo /Ceiling Internal ��� Sensible Infiltration Latent Infiltration Wall Windows q 3000 2000 1000 0 1 i(:r vie ItiIY11 II Y AED Graph Sam 9am 10am llam 12pm 1pm ACCA Manual S 2pm 3pm — Hourly Loads — Average 4pm 5pm 6pm 7pm 8pm System equipment selection will be made using the following Manual S derived values. Summer Outdoor Summer Wet BuIb Summer Indoor Summer Design Grains 92 °F Winter Outdoor Winter Indoor Sensible Cooling Latent Cooling Required Cooling Airflow Sensible Heating Required Heaing Airflow 74 °F 54 °F 14,023 Btuh 637 CFM 216 CFM A;I calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates.. Product provided by Energy Design Systems and Idea Tree - RUUD Design Star Load Calculation ,L,IIP•mmoM11111F Results are intended for use with Ruud heating and cooling systems only Customer Information Location: Street Address 11300 NE 2nd Ave, MIAMI-DADE, FL 33161 Latitude, Longitude 25.7791°, -80.1978° House Square Footage: 572 sq. ft. Name: Barry U - Browne Hall Rms 17/18 Phone: 123-123-1234 Email: example@mail.com Desi n Conditions Outdoor Heating Cooling Dry bulb (°F) 54 92 Daily range L Relative humidity 50% Moisture difference 58 Indoor Heating Cooling Indoor temperature (°F) 68 74 Design temperature difference(°F) 14 18 Heatin. ~ad~a.`�' ;�' Area Btuh % of load Wall 7480 45 Floor 8453 50.9 Ceiling Windows 252 1.5 Infiltration 0 0 System Efficiency Loss 0 0 Total: 16610 Floor - Heating Loads e,610 oru/x, Infiltration System Efficiency Loss Windows Ceiling Wall Coo lino Loads Area Wall Ceiling Btuh % of load 9617 59.5 546 3.4 Windows 2008 12.4 Sensible Infiltration 948 5.9 Latent Infiltration 1888 11,7 System Efficiency Gain 0 0 Internal 642 4 Sensible People Load 263 1.6 Latent People Load 263 1.6 Total: 16175 Sensible load 14023 Latent load 2151 SHR 0.87 Capacity at .87 SHR 1.34 Tons Cooling Loads 16,175 BTUThr Wall ----- 1-- System Efficiency Gain Sensible People Load r-------np"----- Latent People Load / r"-------___:Ceiling Internal :, ',-: r"-------- Sensible Infiltration 44 ,.:., Latent Infiltration Windows �����0�� � Diversit ~�+ '._~~ -.~~__~_.. •_._, � ~-,~~. ~.~ • AEOGraph 3000 -0 0 � 2000 1000 0 — Hourly Loads — Average ..~~~~.. Manual S ' ~ System equipment selection will be made using the following Manual 5 derived values, Summer Outdoor Summer Wet BuIb Summer Indoor Summer Design Grains Winter Outdoor Winter Indoor Sensible Cooling Latent Cooling --------------'—'---'----' Required Cooling Airflow 92°F 77°F 74°F 50% 54°F <58°F 14'033 Btuh 2,151 Btuh 637 CFM Sensible Heating 16,610 Btuh Required Heaing Airflow 216 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. AV computed results are Estimates, Product provided by Energy Design Systems and Idea Tree