MC-12-1345Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 176133 Permit Number: MC -7 -12 -1345 Scheduled Inspection Date: August 13, 2012 Inspector: Perez, JanPierre Owner: SCHOOL INC, MIAMI COUNTRY DAY Job Address: 10653 NE 6 Avenue Miami Shores, FL 33138- Project <NONE> Contractor: JORDA MECHANICAL Permit Type: Mechanical - Commercial Inspection Type: Final Work Classification: A/C Replacement Phone Number (305)759 -2843 Parcel Number 1122310120010 Phone: (305)262 -0095 Building Department Comments CHANGE OUT NC UNITS AMD DUCT WORK. (1) 2 TON (1)4TONAND(1)3TON ett31 Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. August 10, 2012 For Inspections please call: (305)762 -4949 Page 22 of 48 74i I 1Z-5-lituc )\BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: MECHANICAL JOB ADDRESS: I 0 1.0 5 N . E • e RECEIVED JUL 19 2012 r. 20 FBC 20 IO Permit No. MG" 1 Z" 13 44 Master Permit No. City: Miami Shores County: Miami Dade Folio/Parcel #: 11 ^ L23 l ' O — OO 1 0 '' ``� - Is the Building Historically Designated: Yes NO Flood Zone:1i1 tNA .('�\nn' COOS DaL CI�1 05 _ - OWNER: Name (Fee Simple Titleholder): j� lJ���1 `� 1 Phone#: �7 "� ' -I �� Address: I O b 53 N © � . l9 ti 1 \I t_ 111 �rt�. City: M� ■V \\ 'S i b( f 5 State: • Zip 33 t 32 Tenant/Lessee Name: N A /� h, ` /� /� n yes Phone#: Email: 6 0 H. G3 MI CM\ -00 1� "' uLY o o c� CONTRACTOR: Company Name: — bc&A V 9 (\t ' Phone Address: CID) 1 1 Zip: 33 13 City:ri\ Q2..);scoth9_%State: Qualifier Name: State Certification or Registration #: C NICE gLiq Contact Phone #: ° 34S-4 1 t®8 Email Address: - Certificate of Co Zip: Phon -%4 ( tency DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $. Z7 is m Type of Work: Address Alteration Description of Work: Square/Linear Footage of Work: ❑Repair/Replace L 1 ODemolition erg tic �1�► . * * ** ************ * * ********** * *********F ��* + * **** �****** **�x:xa� *** air * ***+� *:x:�:x�xx�x�x� **** Submittal Fee $ 00.O O Permit Fee $ Scanning Fee $ PM Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such postej' notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent 1 ] The foregoing instrument was acknowledged before me this G ,'T1Thi a foregoing instrument was acknowledged before me this 0 7 day of �Vl� ,20 / , by Jr; 44 CW SAP" /4 o is . • rsonally known to me • who has produced who is personally known to me or who hasprodaoed as i€eatiun and who did take an oath. NOTARY PUBLIC: As identification and who did take an oath. NOTARY PUBLIC: Sign: Print I not Nt\ia _AS___ _AS ___ An_ r My Co onExp APPROVED BY "44 LIANA CUEVAS Notary Pubes - state of rlodda C �: Comma # DO 8801908 `V My Comm. Expkes Apr 2. 2013 \lans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10/07)(Revised 06/1012009)(Revised 3/15/09) a Sign: Print: .TD' S F • A t -01.)S° My Corr ii' .i°, JOSE A. ALONSO Commission # DD 937135 Expires February 22, 2014 Boded Thru ?my Fain insuarma :. 7019 Zoning Clerk Miami COUNTRY DAY SCHOOL June 22, 2012 RE: 10653 N.E 6 Ave., Miami Shores, FI. 33138 Folio # 11- 2231 - 012 -0010 To Whom It May Concern: Mr. Gary Butts, Chief Operating Officer is an authorized signer on behalf of the corporation, Miami Country Day School, Inc., owner of the above addressed property. Sincerely, Anne Paulk, President Board of Trustees Miami Country Day School, Inc. )jAflO1\i (0 (2-2.. 1-110c0 00-eVP WIZ 601 Northeast 107 Street I Miami, Florida 33161 1 305.759.2843 1 Fax 305.759.4871 1 www.miamicountryday.org Every Student. Every Day. ACRD CERTIFICATE OF LIABILITY INSURANCE DATE (MM/D4/YYYY) 10/4/2011 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. ;1PORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Brown & -Brown of FL, Inc. - Fort Myers 3820 Colonial Boulevard Suite 200 Fort Myers FL 33912 NAME aMEStephanie Wilkinson PHONE (A/C No Est)* 239-274-1430 FAX (A/C, No):239- 278 -5306 E-MAIL RESS: swilkinson@bbftmyers.com PRODUCER CUSTOMER ID #: INSURER(S) AFFORDING COVERAGE NAIC 1/ INSURED Jorda Enterprises, Inca DBA Jorda Mechanical Contractors 8011 NW 14th St. Miami FL 33126 INSURERA:National Trust Ins Co INSURER B: FCCI Insurance Company INSURER C : INSURER D : INSURER E : INSURER F : COVERAGES CERTIFICATE NUMBER: 769876736 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSR SUBR MD POLICY NUMBER POUCY EFF (MM/D •' D• -' - • • °' ` LIMITS A GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY OCCUR GL00096722 12/31/. s" 0 12/31/2011 EACH OCCURRENCE $1,000,000 X PREMISES Ea occurrence) $100, 000 CLAIMS -MADE X MED EXP (Any one person) $5,000 PERSONAL & ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $2,000,000 7 POLICY X PRO - X LOC JECT $ AUTOMOBILE UABIUTY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS CA00150332 12/31/2010 12/31/2011 COMBINED SINGLE LIMIT (Ea accident) $1,000,000 7( BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ $ A x UMBRELLALIAB EXCESS UAB X OCCUR CLAIMS -MADE UMB00099902 12/31/2010 12/31/2011 EACH OCCURRENCE $3,000,000 AGGREGATE $3,000,000 DEDUCTIBLE RETENTION $10,000 $ X $ g WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) K es, describe under DESCRIPTION OF OPERATIONS Y/ N N / A 67339 10/7/2011 10/7/2012 X WC TATUU- T ER E.L. EACH ACCIDENT $500, 000 N E.L DISEASE - EA EMPLOYEE $500,000 below E.L. DISEASE - POLICY LIMIT $500, 000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, K mom space Is required) 30 days notice of cancellation except 10 days notice for non- payment CERTIFICATE HOLDER CANCELLATION Miami Shores Building & Zoning 10050 NE 2nd Avenue Miami Shores FL 33138 -2304 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ACORD 25 (2009/09) © 1988-2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO 1 d " r 3 14 5 TAX FOLIO NO! /12'3( -0 \ a -O0 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement. 11111111111111111111 1 111111111111111111111111 0 CFN 201.2R0546317 OR Bk 28214 Ps 4727 1 (fps) RECORDED O8/03/2012 10t06 :38 HARVEY R:UVINv CLERK. OF COURT MIAMI -DADE COUNTYv FLORIDA LAST PAGE Space above reserved for use of recording Leg I desc n of •ro • an , t/add , \k e,3 e_s� P\ � 0 k �- � � a b at- v, s "' %�Y�!jY= .�"'mp1Luro r 'fCfii&:�[ (��f �. 2. Description of improvement: }• N/t I ' i es 7 3. Owner(s) name and address: ' Q .. l f (Y c1 tt . Interest in property: 3J 1 Name and address of fee simple titleholder: .4Qon ctoe am address an phone number. pant lam IVit) 14 t2'� 13 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number: d 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number. 9. Expiration date of this Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. iF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT Signature(s) o Prepared By Print Name Title/Office orized Officer/Director/Partner/M Prepared By f/ Print Name Title/Office STATE OF F 0 DA COUNTY OF MIAMI -DADE The foregoing Insbivent was acknowledged before me this / day of By ih YitVi$S ❑ Iqsikidually, or Was O / for _ ersonally knot' ;; or ❑ produced the following type of Identification: Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92:525. FLORIDA STATUTES Under penalties of perjury, I declare that 1 have read the foregoing and that the facts stated In it are true, to the best of my knowledge and belief. Signature(s) of Owner(s) or Owner(s)'s Authorized Officer/Director/Partner/Manager who signed above: By By STATE OF FLORIDA Comm# EE041959 Expires 11/15/2014 123.01 -62 ME 8 3/10 Miami COUNTRY DAY SCHOOL August 1, 2012 RE: 10653 N.E. 6 Ave., Miami Shores, FI. 33138 To Whom It May Concern: Mr. John Davies, Head of School, is an authorized signer on behalf of the corporation, Miami Country Day School, Inc., owner of the above addressed property. Sincerely, F /,ors cF'A- Anne Paulk, President Aourdo de ,J , cr* Board of Trustees AL' * y bi>� Miami Country Day School, Inc. LOURDES DE LA NUERTA NOTARY PUBLIC STATE OF FLORIDA Comm# EEa41 Expires 11/15/2014 601 Northeast 107 Street I Miami, Florida 33161 1 305.759.2843 I Fax 305.759.4871 I www.miamicountryday.org Every Student. Every Day. 1I nulkilliCS CERTIFIED TM www.abridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3591639 Date: 7/19/2012 Product: Split System: Air - Cooled Condensing Unit, Coll with Blower Outdoor Unit Model Number: RANL- 024JAZ Indoor Unit Model Number: RHLL- HM2417 +RCSL -H *2417 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM RANL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Condltioning and Air- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI - sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating _(Cooling): SEER Rating (Cooling): 24800 12.50* 15.00 * Ratings followed by an asterisk (h indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the products) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not in whole or in part be reproduced; copied; disseminated; entered into a computer database; or otherwise utlb eed, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be veriHe! at www.ahrklirectory.org, click on "Verify Certificate" fink and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is fisted above, and the Certificate No., width in listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute A LIMQ, Air- Conditioning, Heating, AI 1I• 'r' and Refrigeration Institute CERTIFICATE NO.: 129871775136669874 Project Name: 12 -044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. a Input Data 07/18/2012 02:34PM 1. General Details: Air System Name a Equipment Type Split AHU Air System Type Single Zone CAV Number of zones 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method Sum of Space OA Airflows Unocc. Damper Position Closed Damper Leak Rate 0 % Outdoor Air CO2 Level 400 ppm Central Cooling Data: Supply Air Temperature b8.0 °F Coil Bypass Factor 0.100 Cooling Source Air- Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration DmW thru Fan Performance 0.00 in wg Overall Efficiency S4 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 5 % Return Duct or Plenum Data: Retum Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 01- storage/toilet x1 02 -office x1 03-office x1 10-office x1 04-kitchen x1 05- office x1 Thermostats and Zone Data: Zone All Cooling T -stat: Occ. 75.0 Cooling T -stat: Unocc. 85.0 Heating T -stat: Occ. 70.0 Heating T -stat: Unocc. 60.0 T-stat Throttling Range 1.50 Diversity Factor 100 Direct Exhaust Airflow 0.0 Direct Exhaust Fan kW 0.0 Thermostat Schedule thermostat Unoccupied Cooling is Available °F °F °F °F °F CFM kW Supply Terminals Data: Zone All Terminal Type Diffuser Minimum Airflow 0.00 CFM/person Hourly Analysis Program v4.51 Page 1 of 6 Project Name: 12-044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. a Input Data 07/18/2012 02:34PM Zone Heating Units: Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (User - Modified): System Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 2204.4 CFM Ventilation Airflow 92.9 CFM Heating Supply Temperature 95.0 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space Toads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) (CFM) 1 2204.4 - - 5. Equipment Data Central Cooling Unit - Air-Cooled DX Estimated Maximum Load 37.4 MBH Design OAT 95.0 °F Equipment Sizing Auto -Sized Capacity Oversizing Factor 0 % ARI Performance Rating 11.00 EER Conventional Cutoff OAT 55.0 °F Low Temperature Operation Used Low Temperature Cutoff OAT 0.0 °F Hourly Analysis Program v4.51 Page 2 of 6 Project Name: 12-044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. b Input Data 07/18/2012 02:34PM 1. General Details: Air System Name b Equipment Type Spin AHU Air System Type Single Zone CAV Number of zones 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method Sum of Space OA Airflows Unocc. Damper Position Closed Damper Leak Rate -O % Outdoor Air CO2 Level 400 ppm Central Cooling Data: Supply Air Temperature 58.0 °F Coil Bypass Factor 0.100 Cooling Source Air - Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0.00 In wg Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Retum Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 06- living x1 Thermostats and Zone Data: Zone All Cooling T -stat: Occ. 75.0 °F Cooling T-stat Unocc. 85.0 °F Heating T -stat: Occ. 70.0 °F Heating T -stat: Unocc. 60.0 °F T -stat Throttling Range 1.50 °F Diversity Factor 100 % Direct Exhaust Airflow 0.0 CFM Direct Exhaust Fan kW 0.0 kW Thermostat Schedule thermostat Unoccupied Cooling is Available Supply Terminals Data: Zone All Terminal Type Diffuser Minimum Airflow 0.00 CFM/person Zone Heating Units: Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Hourly Analysis Program v4.51 Page 3 of 6 Project Name: 12-044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. b Input Data 07/18/2012 02:34PM Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (User - Modified): System Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 1099.9 CFM Ventilatlon Airflow 126.5 CFM Heating Supply Temperature 95.0 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat CoII (MBH) - (CFM) 1 1099.9 - - 5. Equipment Data Central Cooling Unit - Air - Cooled DX Estimated Maximum Load 30.0 MBH Design OAT 95.0 °F Equipment Sizing Auto -Sized Capacity Oversizing Factor 0 % ARI Performance Rating 11.00 EER Conventional Cutoff OAT 55.0 °F Low Temperature Operation Used Low Temperature Cutoff OAT 0.0 °F Hourly Analysis Program v4.51 Page 4 of 6 Project Name: 12 -044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. c Input Data 07/18/2012 02:34PM 1. General Details: Air System Name c Equipment Type Split AHU Air System Type Single Zone CAV Number of zones 1 2. System Components: Ventilation Alr Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method Sum of Space OA Airflows Unocc. Damper Position Closed Damper Leak Rate 0 % Outdoor Air CO2 Level 400 ppm Central Cooling Data: Supply Air Temperature 58.0 °F Coil Bypass Factor 0.100 Cooling Source Air - Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0.00 In wg Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Retum Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 07- office x1 12- restrooms x1 13- hallway x1 11 -foyer x1 08- office x1 09 -office x1 Thermostats and Zone Data: Zone All Cooling T -stat: Occ. 76.0 Cooling T -stat: Unocc. 85.0 Heating T -stat: Occ. 70.0 Heating T -stat: Unocc. 60.0 T -stat Throttling Range 1.50 Diversity Factor 100 Direct Exhaust Airflow 0.0 Direct Exhaust Fan kW 0.0 Thermostat Schedule thermostat Unoccupied Cooling is Available °F °F °F °F °F CFM kW Supply Terminals Data: Zone All Terminal Type Diffuser Minimum Airflow 0.00 CFM /person Hourly Analysis Program v4.51 Page 5 of 6 Project Name: 12-044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. c Input Data 07/18/2012 02:34PM Zone Heating Units: Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (User - Modified): System Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 1246.5 CFM Ventilation Airflow 69.4 CFM Heating Supply Temperature 95.0 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coll (MBH) - (CFM) 1 1246.5 - - 5. Equipment Data Central Cooling Unit - Air - Cooled DX Estimated Maximum Load 22.3 MBH Design OAT 95.0 °F Equipment Sizing Auto -Sized Capacity Oversizing Factor 0 % ARI Performance Rating 11.00 EER Conventional Cutoff OAT 55.0 °F Low Temperature Operation Used Low Temperature Cutoff OAT 0.0 °F Hourly Analysis Program v4.51 Page 6 of 6 .s+u.. l CERTIFIED TM w v }w.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3455196 Date: 7/19/2012 Product: Split System: Air- Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: RANL- 049JAZ Indoor Unit Model Number: RHLL- HM4821 +RCSL -H *4821 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM RANL SERIES Manufacturer responsible for the rating of this system combination is RHEEM Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Heat Pump Equipment and subject to verification of rating accuracy by AHRI- party testing: Cooling Capacity (Btuh): 47000 EE9 Rating _(Cooling): 11.50* SEER Rating (Cooling): 13.50 MANUFACTURING COMPANY Air- Conditioning and Air- Source sponsored, independent, third a which indicates an involuntary rerate. • * Ratings followed by an asterisk (1 indicate a voluntary rerate of previously published data, unless accompanied with a WAS, DISCLAIMER AHRI does not endorse the product(s) fisted on this Certificate and makes no repn sentatlons, warr8ntles or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(.), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations fisted M the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and its contends are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any Trans, except for the user's Individual, personal and confidential reference. CERTIFICATE VERIFICATION �� The information for the model cited on this certificate can be verify at www. ahridirectory.org, Air-Conditioning, Heating, click on "Verity Certificate" Zink and enter the AHRI Certified Reference Number and the date on AN NM r and Refrigeration institute which the certificate was issued, which is fisted above, and the Certificate No., which is fisted below. g ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129871775688705805 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 01- storageltoilet 1. General Details: Floor Area 191.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 0.0 CFMiperson OA Requirement 2 0.00 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/ft2 Schedule None 3. Walls, Windows, Doors: 2.4. People: Occupancy 0.0 Person Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule None 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 96.0 1 0 0 E 170.0 0 2 2 S 96.0 1 0 0 3.1. Construction Types for Exposure N Wall Type Stucco + 8" LW Concrete Block 1st Window Type 3x4 3.2. Construction Types for Exposure E Wall Type Stucco + 8" LW Concrete Block 2nd Window Type 2x3 Door Type exterior steel door 3.3. Construction Types for Exposure S Wall Type Stucco + 8" LW Concrete Block 1st Window Type 3x4 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 191.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. Hourly Analysis Program v4.51 Page 1 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 6. Floors: Type Floor Above Unconditioned Space Floor Area 191.0 ft2 Total Floor U -Value 0.100 BTU /(hr- ft' - °F) Unconditioned Space Max Temp. 76.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 76.0 °F Ambient at Space Min Temp. 55.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 2 of 16 12 -044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 02 -office 1. General Details: Floor Area 215.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User- Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage Schedule 0.00 W/ft2 None 2.3. Electrical Equipment: Wattage 300.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 2.0 People Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 206.0 BTU/hr /person Schedule occupied 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 86.0 1 0 0 S 86.0 1 0 0 3.1. Construction Types for Exposure N Wall Type Stucco + 8" LW Concrete Block 1st Window Type 3x4 3.2. Construction Types for Exposure S Wall Type Stucco + 8" LW Concrete Block 1st Window Type 3x4 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 215.0 0 0 4.1. Construction Types for Exposure H Roof Type lay in ceiling attic with insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 215.0 ft2 Total Floor U -Value 0.100 BTU /(hr- ft2 - °F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 0.00 (hr- 112- °F)BTU 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 3 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 03 -office 1. General Details: Floor Area 280.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft' 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Vented) Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage Schedule 0.00 W/ft2 None 2.3. Electrical Equipment: Wattage 300.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 2.0 People Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. W 190.0 1 0 0 E 190.0 1 0 0 3.1. Construction Types for Exposure W Wall Type Stucco + 8" LW Concrete Block 1st Window Type storefront 1st Window Shade Type 6' awning 3.2. Construction Types for Exposure E Wall Type Stucco + 8" LW Concrete Block 1st Window Type storefront 1st Window Shade Type covered deck 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 280.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 280.0 ft2 Total Floor U -Value 0.100 BTU /(hr -ft' °F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 0.00 (hr -ft' °F)BTU 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 4 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space input Data 07/18/2012 02:36PM 04-kitchen 1. General Details: Floor Area 196.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 Ibfft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFMfft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage Schedule 0.00 W/ft2 None 2.3. Electrical Equipment: Wattage 0.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 0.0 Person Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.6. Miscellaneous Loads: Sensible 1200 BTU/hr Schedule occupied Latent 0 BTU/hr Schedule None Exp. WaII Gross Area (W) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 112.0 1 0 0 3.1. Construction Types for Exposure N Wall Type Stucco + 8" LW Concrete Block 1st Window Type 6x3 1st Window Shade Type 2' overhang 4. Roofs, Skylights: Exp. Roof Gross Area (ft') Roof Slope (deg.) Skylight Qty. H 196.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with Insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Unconditioned Space Floor Area 196.0 ft2 Total Floor U -Value 0.100 BTU/Mr-112-T) Unconditioned Space Max Temp. 76.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 76.0 °F Ambient at Space Min Temp. 55.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 5 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 06- office 1. General Details: Floor Area 175.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 Ib/ft° 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage Schedule 0.00 W/ft2 None 2.3. Electrical Equipment: Wattage 150.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 1.0 Person Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.6. Miscellaneous Loads: Sensible 0 BTU/hr Schedule occupied Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. N 94.0 1 0 0 W 114.0 1 0 0 3.1. Construction Types for Exposure N Wall Type Stucco + 8" LW Concrete Block 1st Window Type 5x5 1st Window Shade Type 2' overhang 3.2. Construction Types for Exposure W Wall Type Stucco + 8" LW Concrete Block 1st Window Type 5x5 1st Window Shade Type 2' overhang 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 175.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with Insulation 6. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Unconditioned Space Floor Area 175.0 ft2 Total Floor U -Value 0.100 BTU /(hr -ft2 °F) Unconditioned Space Max Temp. 75.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 75.0 °F Ambient at Space Min Temp. 55.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 6 of 16 12 -044 Sommers Hall HalQwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 06 -lMng 1. General Details: Floor Area 442.0 ft2 Avg. Ceiling Height 11.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 6.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 20.0 People Wattage 1.00 W/ft2 Activity Level Sedentary Work Ballast Multiplier 1.26 Sensible 280.0 BTU/hr /person Schedule occupied Latent 270.0 BTU/hr /person Schedule occupied 2.2. Task Lighting: 2.5. Miscellaneous Loads: Wattage 0.00 W/ft2 Sensible 0 BTU/hr Schedule None Schedule occupied Latent 0 BTU/hr Schedule None 2.3. Electrical Equipment: Wattage 0.0 Watts Schedule occupied 3. Walls, Windows, Doors: Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 236.0 1 1 1 3.1. Construction Types for Exposure W Wall Type Stucco + 8" LW Concrete Block 1st Window Type 6x8 2nd Wndow Type entry sidelights 2nd Window Shade Type entry alcove Door Type exterior steel door 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. W 257.0 30 0 E 257.0 30 0 4.1. Construction Types for Exposure W Roof Type cathedral no instil 4.2. Construction Types for Exposure E Roof Type cathedral no insul 6. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Unconditioned Space Floor Area 442.0 ft* Total Floor U -Value 0.100 BTU /(hr- ft2- °F) Unconditioned Space Max Temp. 75.0 °F Ambient at Space Max Temp. 96.0 °F Unconditioned Space Min Temp. 76.0 °F Ambient at Space Min Temp. 65.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 7 of 16 12 -044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 07- office 1. General Details: Floor Area 210.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fbcture Type Free Hanging Wattage 1.00 W/f? Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage 0.00 W/ft' Schedule None 2.3. Electrical Equipment: Wattage 300.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 2.0 People Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule occupied Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 120.0 1 0 0 S 112.0 1 0 0 N 24.0 0 0 0 3.1. Construction Types for Exposure W Wall Type Stucco + 8" LW Concrete Block 1st Window Type 6x4 1st Window Shade Type 3' awning 3.2. Construction Types for Exposure S Wall Type Stucco + 8" LW Concrete Block 1 st Wndow Type 6x4 1st Window Shade Type 3' awning 3.3. Construction Types for Exposure N Wall Type Stucco + 8" LW Concrete Block 4. Roofs, Skylights: Exp. Roof Gross Area (ft') Roof Slope (deg.) Skylight Qty. H 210.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. Hourly Analysis Program v4.51 Page 8 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 6. Floors: Type Floor Above Unconditioned Space Floor Area 210.0 ft' Total Floor U -Value 0.100 BTU/(hr-ft2-°F) Unconditioned Space Max Temp. 75.0 °F Ambient at Space Max Temp. 96.0 °F Unconditioned Space Min Temp. 76.0 °F Ambient at Space Min Temp. 55.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 9 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 08- office 1. General Details: Floor Area 186.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 6.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 1.0 Person Wattage 1.00 W/ft2 Activity Level Office Work Ballast Multiplier 1.25 Sensible 246.0 BTU/hr /person Schedule occupied Latent 206.0 BTU/hr /person Schedule occupied 2.2. Task Lighting: 2.6. Miscellaneous Loads: Wattage 0.00 W/ft2 Sensible 0 BTU/hr Schedule None Schedule occupied Latent 0 BTU/hr Schedule None 2.3. Electrical Equipment: Wattage 160.0 Watts Schedule occupied 3. Walls, Windows, Doors: Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. S 126.0 2 0 0 E 94.0 1 0 0 N 64.0 1 0 0 3.1. Construction Types for Exposure 5 Wall Type Stucco + 8" LW Concrete Block 1st Window Type 6x4 1st Window Shade Type 3' awning 3.2. Construction Types for Exposure E Wall Type Stucco + 8" LW Concrete Block 1st Window Type 6x4 1st Window Shade Type 6' awning 3.3. Construction Types for Exposure N Wall Type Stucco + 8" LW Concrete Block 1st Window Type 6x4 1st Window Shade Type covered deck 4. Roofs, Skylights: Exp. Roof Gross Area (ft *) Roof Slope (deg.) Skylight Qty. H 185.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with insulation 6. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM infiltration occurs only when the fan is off. Hourly Analysis Program v4.51 Page 10 of 16 12-044 Sommers Hall Hatliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 6. Floors: Type Floor Above Unconditioned Space Floor Area 186.0 ft' Total Floor U -Value 0.100 BTU /(hr- ft' -- °F) Unconditioned Space Max Temp. 76.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 75.0 °F Ambient at Space Min Temp. 56.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 11 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 09 -office 1. General Details: Floor Area 182.0 ft2 Avg. Ceiling Height 11.0 ft Building Weight 70.0 Ib/fi2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.08 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.26 Schedule occupied 2.2. Task Lighting: Wattage Schedule 0.00 W/ft2 None 2.3. Electrical Equipment: Wattage 150.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 1.0 Person Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule occupied Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. E 104.0 1 0 0 3.1. Construction Types for Exposure E Wall Type Stucco + 8" LW Concrete Block 1st Window Type 9x6 1st Window Shade Type covered deck 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. E 208.0 30 0 4.1. Construction Types for Exposure E Roof Type cathedral no Insul 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 182.0 ft2 Total Floor U -Value 0.100 BTU /(hr- ft2- 2F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 0.00 (hr- ft2- °F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 12 of 16 12-044 Sommers Hall Halliwetl Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 10 -office 1. General Details: Floor Area 182.0 ft' Avg. Ceiling Height 11.0 ft Building Weight 70.0 lb/ft' 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft' Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 1.0 Person Wattage 1.00 W/ft' Activity Level Office Work Ballast Multiplier 1.25 Sensible 245.0 BTU/hr /person Schedule occupied Latent 205.0 BTU/hr /person Schedule occupied 2.2. Task Lighting: 2.5. Miscellaneous Loads: Wattage 0.00 W/ft' Sensible 0 BTU/hr Schedule None Schedule occupied Latent 0 BTU/hr Schedule None 2.3. Electrical Equipment: Wattage 150.0 Watts Schedule occupied 3. Walls, Windows, Doors: Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. E 104.0 1 0 0 3.1. Construction Types for Exposure E Wall Type Stucco + 8" LW Concrete Block 1st Window Type 9x6 1st Window Shade Type covered deck 4. Roofs, Skylights: Exp. Roof Gross Area (ft') Roof Slope (deg.) Skylight Qty. E 208.0 30 0 4.1. Construction Types for Exposure E Roof Type cathedral no insul 6. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 182.0 ft' Total Floor U -Value 0.100 BTU/(hr-ft2-°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 0.00 (hr -ft' °F)BTU 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 13 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 11 -foyer 1. General Details: Floor Area 64.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 0.0 Person Wattage 1.00 W/ft2 Activity Level Office Work Ballast Multiplier 1.25 Sensible 245.0 BTU/hr /person Schedule occupied Latent 205.0 BTU/hr /person Schedule occupied 2.2. Task Lighting: 2.5. Miscellaneous Loads: Wattage 0.00 W/ft2 Sensible 0 BTU/hr Schedule None Schedule occupied Latent 0 BTU/hr Schedule None 2.3. Electrical Equipment: Wattage 0.0 Watts Schedule occupied 3. Walls, Windows, Doors: Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. E 56.0 0 0 1 3.1. Construction Types for Exposure E Wall Type Stucco + 8" LW Concrete Block Door Type exterior steel door 4. Roofs, Skylights: Exp. Roof Gross Area on Roof Slope (deg.) Skylight Qty. H 54.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Unconditioned Space Floor Area 54.0 ft2 Total Floor U -Value 0.100 BTU /(hr- ft2- °F) Unconditioned Space Max Temp. 75.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 76.0 °F Ambient at Space Min Temp. 66.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 14 of 16 12-044 Sommers Hall Hailiwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 12- restrooms 1. General Details: Floor Area 92.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User - Defined 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 0.0 Watts Schedule occupied 3. Walls, Windows, Doors: 2.4. People: Occupancy 0.0 Person Activity Level Office Work Sensible 246.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule occupied Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. S 92.0 1 0 1 3.1. Construction Types for Exposure S Wall Type Stucco + 8" LW Concrete Block 1st Window Type 3x4 1st Window Shade Type 3' awning Door Type 4. Roofs, Skylights: exterior steel door Exp. Roof Gross Area (ft') Roof Slope (deg.) Skylight Qty. H 92.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with Insulation 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Unconditioned Space Floor Area 54.0 ft2 Total Floor U -Value 0.100 BTU /(hr- ft2 - - °F) Unconditioned Space Max Temp. 75.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 75.0 °F Ambient at Space Min Temp. 65.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 15 of 16 12-044 Sommers Hall Halliwell Engineering Associates, Inc. Space Input Data 07/18/2012 02:36PM 13- hallway 1. General Details: Floor Area 100.0 ft2 Avg. Ceiling Height 8.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User - Defined OA Requirement 1 6.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults User- Defined 2. Internals: 2.1. Overhead Lighting: Fbcture Type Free Hanging Wattage 1.00 W/ft2 Ballast Multiplier 1.25 Schedule occupied 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 0.0 Watts Schedule occupied 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 0.0 Person Activity Level Office Work Sensible 245.0 BTU/hr /person Latent 205.0 BTU/hr /person Schedule occupied 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule occupied Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 100.0 0 0 4.1. Construction Types for Exposure H Roof Type gyp ceiling attic with insulation 6. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 CFM Energy Analysis 0.00 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Unconditioned Space Floor Area 54.0 ft2 Total Floor U -Value 0.100 BTU /(hr- ft2- °F) Unconditioned Space Max Temp. 75.0 °F Ambient at Space Max Temp. 95.0 °F Unconditioned Space Min Temp. 75.0 °F Ambient at Space Min Temp. 55.0 °F 7. Partitions: (No partition data). Hourly Analysis Program v4.51 Page 16 of 16 �i :R1 CERTIFIED,,, www.ahridirectory.org Certificate of Product Ratin9s AHRI Certified Reference Number: 3396236 Date: 7/19/2012 Product: Spilt System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: RANL- 037JAZ Indoor Unit Model Number: RHLL- HM3617 +RCSL -H *3617 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM RANL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 39000 EER R to ing (Cooling) _ 11.50""- SEER Rating (Cooling): 14.00 Y -m. ., . -- , _ * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warrantees or guarantee as to, and assumes no responsibfity for, the product(s) listed on the Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certif(cate. Certified rulings are valid only for models and configurations listed In the directory at www.ahrldIrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of Alin The Certificate shall only be used for Indivldual, personal and confidential reference purposes. The contents of the Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be veriflei atwww.ahrktlrectory.org, A Air`Conditioning, Healing, click on "Verify Certificate" tlnk and enter the AHRI Certlfled Reference Number and the date on .u' and Refrigeration institute which the certificate was issued, which Is listed above, and the CertMcate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129871774613608486 i Air System Sizing Summary for a Project Name: 12 -044 Sommers Hall Prepared by: Hailiwell Engineering Associates, Inc. 07/18/2012 02:38PM Air System Information Air System Name a Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space Toads Central Cooling Coil Sizing Data Total coil load 3.1 Tons Total coil load 37.4 MBH Sensible coil Toad 33.8 MBH Coil CFM at Jul 1600 2204 CFM Max block CFM 2204 CFM Sum of peak zone CFM 2320 CFM Sensible heat ratio 0.903 ft2/Ton 397.3 BTU /(hr -ft2) 30.2 Water flow CO 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 16.6 MBH Coil CFM at Des Htg 2204 CFM Max coil CFM 2204 CFM Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 2204 CFM Standard CFM 2203 CFM Actual max CFM/ft2 1.78 CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM 93 CFM CFM/ft2 0.07 CFM/ft2 Number of zones 1 Floor Area 1239.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Sizing Data User - Modified Load occurs at Jul 1600 OADB /WB 90.7/76.9 °F Entering DB / WB 76.0 / 66.2 °F Leaving DB / WB 61.8 / 60.9 °F Coil ADP 60.3 °F Bypass Factor 0.100 Resulting RH 59 % Design supply temp. 55.0 °F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Load occurs at Des Htg BTU /(hr -ft2) 13.4 Ent. DB / Lvg DB 69.2 / 76.2 °F Fan motor BHP 0.00 BHP Fan motor kW 0.00 kW Fan static 0.00 in wg CFM/person 15.48 CFM/person Hourly Analysis Program v4.51 Page 1 of 9 Project Name: 12-044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. Zone Sizing Summary for a 07/18/2012 02:38PM Air System Information Air System Name a Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Zone Sizing Data Number of zones 1 Floor Area 1239.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Sizing Data User - Modified Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Zone 1 35.2 2204 2204 Jul 1600 14.5 1239.0 1.78 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name MuIt. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area MI Space CFM/ft2 Zone 1 01- storage/toilet 1 3.7 Jul 1600 232 2.7 191.0 1.22 02 -office 1 4.3 Jul 1600 268 1.6 215.0 1.25 03 -office 1 13.6 Jul 1600 853 4.2 280.0 3.05 10 -office 1 5.3 Jul 1600 332 2.6 182.0 1.83 04- kitchen 1 3.6 Jul 1600 224 1.2 196.0 1.14 05- office 1 4.7 Jul 1600 295 2.2 175.0 1.69 Hourly Analysis Program v4.51 Page 2 of 9 Air System Design Load Summary for a Project Name: 12-044 Sommers Hall Prepared by: Hatliwell Engineering Associates, Inc. 07/18/2012 02:38PM Hourly Analysis Program v4.51 Page 3 of 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB /1/103 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 486 ft2 9799 - 486 ft2 - - Wall Transmission 849 ft2 3242 - 849 ft2 4329 - Roof Transmission 1265 ft2 6970 - 1265 ft2 2851 - Window Transmission 486 ft2 4198 - 486 ft2 7270 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 3 ft2 12 - 3 ft2 20 - Floor Transmission 1239 ft2 0 - 1239 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1549 W 5284 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 900 W 3071 - 0 0 - People 6 1470 1230 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 1200 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 36246 1230 - 14471 0 Zone Conditioning - 33945 1230 - 14970 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 2204 CFM 0 - 2204 CFM 0 - Ventilation Load 93 CFM 1531 2414 93 CFM 2424 0 Supply Fan Load 2204 CFM 0 - 2204 CFM 0 - Space Fan Coil Fans - 0 - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 35476 3644 - 17395 0 Central Cooling Coil - 33779 3646 - 0 0 Central Heating Coil - 0 - - 16646 - » Total Conditioning - 33779 3646 - 16646 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg Toads Negative values are clg loads Hourly Analysis Program v4.51 Page 3 of 9 Protect Name: 12-044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. Air System Sizing Summary for b 07/18/2012 02:38PM Air System Information Air System Name b Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Number of zones 1 Floor Area 442.0 ft2 Location Miami IAP, Florida Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data User - Modified Central Cooling Coil Sizing Data Total coil load 2.5 Tons Load occurs at Jun 1500 Total coil load 30.0 MBH OA DB / WB 90.0 / 77.0 °F Sensible coil Toad 21.2 MBH Entering DB / WB 77.4/67.3 °F Coil CFM at Jun 1500 1100 CFM Leaving DB / WB 59.6 / 58.6 °F Max block CFM 1100 CFM Coil ADP 67.6 °F Sum of peak zone CFM 1100 CFM Bypass Factor 0.100 Sensible heat ratio 0.706 Resulting RH 60 % ft2/Ton 177.0 Design supply temp. 65.0 °F BTU /(hr -fly 67.8 Zone T -stat Check 1 of 1 OK Water flow © 10.0 °F rise N/A Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil Toad 8.8 MBH Load occurs at Des Htg Coil CFM at Des Htg 1100 CFM BTU/(hr - -ft') 20.0 Max coil CFM 1100 CFM Ent. DB / Lvg DB 67.3 / 74.7 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1100 CFM Fan motor BHP 0.00 BHP Standard CFM 1099 CFM Fan motor kW 0.00 kW Actual max CFM/ft2 2.49 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 127 CFM CFM/person 6.33 CFM/person CFM/ft2 0.29 CFM/ft2 Hourly Analysis Program v4.51 Page 4 of 9 Protect Name: 12 -044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. Zone Sizing Summary for b 07/18/2012 02:38PM Air System Information Air System Name b Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Zone Sizing Data Number of zones 1 Floor Area 442.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Sizing Data User- Modified Zone Name Maximum Cooling Sensible (MBH) Design Mr Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft') Zone CFMIft2 Zone 1 19.6 1100 1100 Jul 1500 5.4 442.0 2.49 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name 1 Space Name Mutt. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft') Space CFMHt° Zone 1 06- living 1 19.6 Jul 1500 1100 5.4 442.0 2.49 Hourly Analysis Program v4.51 Page 5 of 9 Air System Design Load Summary for b Project Name: 12 -044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. 07/18/2012 02:38PM Hourly Analysis Program v4.51 Page 6 of 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB /111/B 90.0 °F / 77.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 70 ft2 2456 - 70 ft2 - - Wail Transmission 165 ft2 522 - 165 ft2 840 - Roof Transmission 514 ft2 8073 - 514 ft2 3022 - Window Transmission 70 ft2 811 - 70 ft2 1503 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 1 ft2 5 - 1 ft2 10 - Floor Transmission 442 ft2 0 - 442 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiting 0 ft2 0 - 0 ft2 0 - Overhead Lighting 553 W 1885 - 0 0 - Task Lighting 0 W 0 - 0 0 - Etectric Equipment 0 W 0 - 0 0 - People 20 5600 5400 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 19353 5400 - 5375 0 Zone Conditioning - 19209 5400 - 5561 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 1100 CFM 0 - 1100 CFM 0 - Ventilation Load 127 CFM 1948 3411 127 CFM 3283 0 Supply Fan Load 1100 CFM 0 - 1100 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 21157 8811 8844 0 Central Cooling Coil - 21157 8813 - 0 0 Central Heating Coil - 0 - - 8844 - » Total Conditioning - 21157 8813 - 8844 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg toads Negative values are clg loads Hourly Analysis Program v4.51 Page 6 of 9 Project Name: 12 -044 Sommers Hall Prepared by: Hailiwell Engineering Associates, Inc. Air System Sizing Summary for c 07/18/2012 02:38PM Air System Information Air System Name c Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Central Cooling Coil Sizing Data Total coil Toad 1.9 Tons Total coil load 22.3 MBH Sensible coil load 19.8 MBH Coil CFM at Jul 1400 1246 CFM Max block CFM 1246 CFM Sum of peak zone CFM 1246 CFM Sensible heat ratio 0.884 ft2/Ton 442.0 BTU /(hr -ft2) 27.2 Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 11.3 MBH Coil CFM at Des Htg 1246 CFM Max coil CFM 1246 CFM Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1246 CFM Standard CFM 1246 CFM Actual max CFM/ft2 1.51 CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM 69 CFM CFM/ft2 0.08 CFM/ft2 Number of zones 1 Floor Area 823.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Sizing Data User - Modified Load occurs at Jul 1400 OADB /WB 90.7 /76.9 °F Entering DB / WB 76.7 / 66.7 °F Leaving DB / WB 62.0 / 61.1 °F Coil ADP 60.4 °F Bypass Factor 0.100 Resulting RH 60 % Design supply temp. 56.0 °F Zone T -stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Load occurs at Des Htg BTU /(hr -ft2) 13.7 Ent. DB / Lvg DB 68.3 / 76.7 °F Fan motor BHP 0.00 BHP Fan motor kW 0.00 kW Fan static 0.00 in wg CFM/person 17.35 CFM/person Hourly Analysis Program v4.51 Page 7 of 9 Project Name: 12 -044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. Zone Sizing Summary for c 07/18/2012 02:38PM Air System Information Air System Name c Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Zone Sizing Data Number of zones 1 Floor Area 823.0 ft2 Location Miami IAP, Florida Calculation Months Jan to Dec Sizing Data User - Modified Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft' Zone 1 19.3 1246 1246 Jul 1400 9.7 823.0 1.51 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft') Space CFM/fta Zone 1 07- office 1 5.0 Jul 1400 325 2.4 210.0 1.55 12- restrooms 1 1.3 Jul 1400 83 0.8 92.0 0.90 13- hallway 1 0.9 - Jul 1400 56 0.2 100.0 0.56 11 -foyer 1 0.7 Jul 1400 48 0.4 54.0 0.89 08- office 1 5.1 Jul 1400 330 3.3 185.0 1.79 09 -office 1 6.2 Jul 1400 404 2.6 182.0 2.22 Hourly Analysis Program v4.51 Page 8 of 9 Protect Name: 12 -044 Sommers Hall Prepared by: Halliwell Engineering Associates, Inc. Air System Design Load Summary for c 07/18/2012 02:38PM Hourly Analysis Program v4.51 Page 9 of 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OA DB / WB 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 210 ft2 1989 - 210112 - - Wall Transmission 579 ft2 2001 - 579 ft2 2953 - Roof Transmission 849 ft' 6172 - 849 ft' 2221 - Window Transmission 210 ft2 2563 - 210 ft2 4526 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 3 ft2 11 - 3 ft2 20 - Floor Transmission 739 ft2 0 - 739 ft' 0 - Partltions 0 ft' 0 - 0 ft2 0 - Ceiiing 0 ft2 0 - 0 ft2 0 - Overhead Ughting 1029 W 3510 - 0 0 - Task Ughting 0 W 0 - 0 0 - Electric Equipment 600 W 2047 - 0 0 - People 4 980 820 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 19273 820 - 9720 0 Zone Conditioning - 18645 820 - 9543 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Ughting Load 0% 0 - 0 0 - Retum Fan Load 1246 CFM 0 - 1246 CFM 0 - Ventilation Load 69 CFM 1105 1773 69 CFM 1767 0 Supply Fan Load 1246 CFM 0 - 1246 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 19761 2693 - 11310 0 Central Cooling Coll - 19751 2594 - 0 0 Central Heating Coil - 0 - - 11310 - Total Conditioning - 19751 2594 - 11310 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.51 Page 9 of 9 13X4 OA INTAKE WITH BIRDSCREEN, UNDER SOFFITT, 130 CFM 13X4 OA 10' -0" MIN ROVIDE 7" WALL CAP WITH BACKDRAFT DAMPER 7 "0 METAL EXHAUST DUCT OOD BY OWNER 2— OFFICE RG -2 14 "0 SD -1 3— OFFICE G-3 2 X10 "0 RG -2 SD -1 10 "0 295 AHU -2 SEE DETAIL 18X12 SA SD -3 30 12°0 !1j� SG-2 550 RG- 10 "0, (2) RG -3 AHU -3 SEE DETAIL 9— OFFICE RG -3 SG -1 405 10 "0,(2)RG -3 10 "0,(2)RG- 7— OFFICE • " WALL INTAKE WITH BIRDSCREEN, 70 CFM OA 10 "0,(2)RG -3 0 CU -3 10 "0 8— OFFICE PLAN APPROXIMATE SCALE: 1/8" = 1' O CU -2 0 CU -1 WALL INTAKE WITH BIRDSCREEN, 95 CFM OA SUPPLY AIR DUCT AH RETURN GRILLE WITH OB FLOOR RECEIVED JUL 192012 I3Y: �Q L M C- (a - (34S. Miami Shore Village APPROVED BY DATE ZONING DEPT BLDG DEPT SUBJECT 10 CCAIFI.IANCE W1 fri ALL FEDERAL STATE ANIJ Cr IJN , (RLLES AND REGULATIONS OUTSIDE AIR DUCT VD RETURN PLENUM (FIBERGLASS DUCTBOARD) AHU SUPPORT AHU DETAIL NTS MIA; TRY DAY SCHOOL SOMMER HALL CEMENT 3/16/2012 PAGE 1 OF 2 DUCTWORK SCHEDULE MAIN SUPPLY AND RETURN DUCTWORK: RIGID FIBERGLASS, R6.0 MINIMUM BRANCH DUCTWORK: FLEXIBLE WITH INSULATION AND VAPOR BARRIER, R6.0 MINIMUM OUTSIDE AIR DUCTWORK: GALVANIZRD STEEL SHEET METAL WITH EXTERNAL FIBERGLASS BALNKET INSULATION, R6.0 MINIMUM. SEAL ALL DUCTWORK TO SMACNA CLASS A (ALL SEAMS SEALED WITH FOIL TAPE OR MASTIC). DIFFUSER AND GRILLE SCHEDULE SD -1: SURFACE MOUNT, 4 WAY THROW, 12X12 NECK, ALUMINUM, W /OBD, TITUS MCD -AA SD -2: 2X2 LAY IN, 4 WAY THROW, ALUMINUM, W /OBD, TITUS MCD -AA SD -3: SURFACE MOUNT, 4 WAY THROW, 6X6 NECK, ALUMINUM, W /OBD, TITUS MCD -AA SG -1: SIDEWALL GRILLE DOUBLE DEFLECTION, 12X12, ALUMINUM, W /OBD, TITUS 300FS SG-2: SIDEWALL GRILLE: DOUBLE DEFLECTION, 14X14, ALUMINUM, W /OBD, TITUS 300FS RG -1: RETURN GRILLE, 20W X 24 H, FIXED 35 DEG HORIZONTAL BLADES, 3/4" SPACING, STEEL, W /OBD, 'TITUS 350RS RG -2: FILTER RETURN GRILLE, 24X24, FIXED 35 DEGREE BLADES, 1/2" SPACING, 1" FILTER, ALUMINUM, TINS 355FLF1 RG-3: RETURN GRILLE, EGG CRATE, 12X12 SIZE, 1 /2X1 /2 OPENINGS, SURFACE MOUNT, ALUMINUM, TITUS 50F NOTES: 1. PROVIDE ROUND DUCT ADAPTER TO MATCH DUCT SIZE. 2. ALL DIFFUSERS AND GRILLES SHALL HAVE WHITE PAINTED FINISH. ABBREVIATIONS' AHU AIR HANDLING UNIT BTU /HR BRITISH THERMAL UNITS /HOUR CFM CUBIC FEET PER MINUTE CU CONDENSING UNIT KW KILOWATT NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER RA RETURN AIR RG RETURN GRILLE SA SUPPLY AIR SD SUPPLY DIFFUSER VD MANUAL VOLUME DAMPER 0 DIAMETER SD DUCT SMOKE DETECTOR AIR CONDITIONING UNIT SCHEDULE; AIR HANDUNG UNIT AHU -1: SYSTEM NOMINAL SIZE: 3.5 TONS REFRIGERANT: R410A MINIMUM SEER: 14 2200 CFM AIRFLOW 95 CFM OUTSIDE AIRFLOW TOTAL CAPAICTY: 37,400 BTU /HR SENSIBLE CAPAICTY: 33,800 BTU/HR 5 KW ELECTRIC HEATER HIGH EFFICIENCY MOTOR CONSTANT VOLUME TRANE XB4FWH OR EQUAL CONDENSING UNIT CU -1: SYSTEM NOMINAL SIZE 3.5 TONS ONE STAGE COOUNG PROVIDE R410A UNESET TRANE XR13 OR EQUAL AIR HANDUNG UNIT AHU -2: SYSTEM NOMINAL SIZE 2.5 TONS REFRIGERANT: R41OA MINIMUM SEER: 14 1100 CFM AIRFLOW 130 CFM OUTSIDE AIRFLOW TOTAL CAPAICTY: 30,000 BTU /HR SENSIBLE CAPAICTY: 21,200 BTU/HR 3 KW ELECTRIC HEATER HIGH EFFICIENCY MOTOR CONSTANT VOLUME TRANE XB4FWH OR EQUAL CONDENSING UNIT CU -2 SYSTEM NOMINAL SIZE: 2.5 TONS ONE STAGE COOUNG PROVIDE R410A UNESET TRANE XR13 OR EQUAL AIR HANDUNG UNIT AHU -3: SYSTEM NOMINAL SIZE: 2 TONS REFRIGERANT: R410A MINIMUM SEER: 14 1250 CFM AIRFLOW 70 CFM OUTSIDE AIRFLOW TOTAL CAPAICTY: 22,300 BTU /HR SENSIBLE CAPAICTY: 19,800 BTU/HR 3.5 KW ELECTRIC HEATER HIGH EFFICIENCY MOTOR CONSTANT VOLUME TRANE XB4FWH OR EQUAL CONDENSING UNIT CU -3: SYSTEM NOMINAL SIZE: 2 TONS ONE STAGE COOLING PROVIDE R410A UNESET TRANE XR13 OR EQUAL THERMOSTATS: 7 DAY PROGRAMMABLE WITH ONE SETBACK AUTO CHANGEOVER MIAMI; AtPrEMENT NTRY DAY SCHOOL SOMMER HA�� 3/15/2012 PAGE 2 OF 2