Loading...
RF-12-236Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 177656 Permit Number: RF -2 -12 -236 Scheduled Inspection Date: August 23, 2012 Inspector: Rodriguez, Jorge Owner: SANDOVAL, RICARDO Job Address: 610 NE 105 Street Miami Shores, FL 33138 -2054 Project: <NONE> Contractor: ESR FLORIDA CONSTRUCTION INC Permit Type: Roof Inspection Type: Final Work Classification: Hurricane Mitigation Phone Number Parcel Number 1122310120160 Phone: (305)812 -2716 Building Department Comments HURRICANE ROOF MITIGATION OPEN AREAS OF MITIGATION, ATTACH STRAPPING ACCORDING TO PLANS NEW PLYWOOD ON AREAS OF MITIGATION Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 169863. August 23, 2012 For Inspections please call: (305)762 -4949 Page 22 of 31 Charles C. Mitchell, P.E. 924 N. Federal Hwy. Hollywood, Fl. 33023 Civil /Structural #11127 305 - 336 -5069 "As -Built Certificate" August 14, 2012 Building Official Village of Miami Shores, FL Re: Re- Roofing 610 N.E. 105th St. Miami Shores, FL 33138 1-11c) l000F I Charles Mitchell, attest that to the best of my knowledge, the structure of the property meet code in all of the following explained in detail as follows: Dear Building Official, Re- Roofing Inspection: Roof: The straps used to anchor the trusses in the re- roofing are 24" x 2" L -shape 13ga. Galvanized steel with 2 -'/° thru bolts with Y2" washers into the trusses and 1- '/9 anchor bolt with 1 /2" washer and epoxy into the existing tie beam at each corner. This is sufficient to secure and prevent uplift on the roof. Sincerely, Charles Mitchell Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 1O- -1`179 Inspection Number: INSP - 177659 Permit Number: RF -8 -10 -1480 Scheduled Inspection Date: August 23, 2012 Inspector: Rodriguez, Jorge Owner: SANDOVAL, RICARDO Job Address: 610 NE 105 Street Miami Shores, FL 33138 -2054 Project: <NONE> Contractor: ESR FLORIDA CONSTRUCTION INC Permit Type: Roof Inspection Type: Final Work Classification: Hurricane Mitigation Phone Number Parcel Number 1122310120160 Phone: (305)812 -2716 Building Department Comments STRAPPING AS REQUIRED FOR RE ROOF OF FLAT DECKING (RF10 -1479) AS PER BUILDING OFFICIAL, OK TO EXTEND PERMIT UNTIL THE END OF FEBRUARY. 2/3/12 Passed r Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 150174. August 23, 2012 For Inspections please call: (305)762-4949 Page 25 of 31 Charles C. Mitchell, P.E. 924 N. Federal Hwy. Hollywood, FI. 33023 Civil /Structural #11127 305 - 336 -5069 "Roof Mitigation" Aug. 14, 2011 Building Official Building & Zoning Dept. Miami Shores, FI. Re: Roof Mitigation for flat Roof 610 N.E. 105St. Miami Shores, FI. 33138 'Kir 0-140 I Charles Mitchell, attest that to the best of my knowledge the structure of the property meet code in all of the following explained in detail as follows: Code: FBC 2010 Dear Building Official, Roof (flat roof): The Nuvue NVRT 24 uplift strap tie was wrapped around the existing 2 "x8" p.t. wood rafters with 9 - 1/4" diameter tapcon screws to the concrete beam and 7- 16d nails to the truss is sufficient to secure and prevent uplift on the roof. Each comer of the roof was opened and the above detail was determined by visual inspection. Sincerly, di Charles Mitchell, P.E. BUILDING PERMIT APPLICATION FBC 20 01 Permit hype: BUILDING „..) OWNER: Name (Fee Simple Titleholder): iL ChitLA:0 N004111c.. Phon :Jlii 60 ? gage Address:_4'll' s City: AR4* J tig State: Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. ._2--- - Master Permit No. Tenant/Lessee Name: Email: elk Zip: 3 Phone #: JOB ADDRESS: 40O City: Folio/Parcel #: Miami Shores N2 X55 1 sr County: Miami Dade Zip: 33/3? Is the Building Historically Designated: Yes CONTRAC Address: City: Qualifier Name: State Certificatio Contact Phone NO ✓ Flood Zone: Phone #. (65) g --)9/4, • Co Name: ,.� 4.. s --• &ca. or Regi ation #: C6 Cd 65-0 a - Certificate of Compe ncy #: 36 j J »/2 ea - j'ifs Email Addr Phone( polefiggikgia Phone DESIGNER: ATchitect/Engineer: giP: 53716 365)a- q z2 r la 3b &' Value of Work for this Permit: $ & 6.. Square/Linear Foo Description of Work: Type of Work: DAddition / OAlteration u„ Z /c4tA/i. POI Ate 45 rn f Work: epair/Replace ODemolition Yrpi44Wb ** ****** **** **** x**************x:**** Fees****** ********** ******+ xe:+ x*+x**+x****e:+x***a:**** vy Submittal Fee $ UU Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate'and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A ' NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subfefto a .n hment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspectfo''whic o urs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not�b- appro ed and a reinspection fee will be charged. Signature Signature Qlwner or Agent The foregoing instrument was acknowledged before me this day of ,20_,by who is personally known to me or who has produced, As identification and who did take an oath. NOTARY ,U L Sign: Print: " V, pop d n e ' My C00114BYMIEIVIOSIZTE OF.FLOAIDA Alexander Martinez Y4ll'! 'Commission #DD898964 J Expires: JUNE 15, 2013 • Contractor The foregoing instrument was acknowledged before me this day of , 20 _, by. who is personally known to me or who has produced as identification and who did take an oath. My Commiss Expire NOTARY ion PUBLIC -STs: ATE OF FLORDA e""1""•1. Alexander Martinez tic: = Commissio ! # / BONDED THRIIATLANTICBONDIN(}COFri1�;, APPROVED BY U' /9 Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Dec. 14, 2011 Building Official Building & Zoning Dept. Miami Shores, Fl. Re: Roof Mitigation 610 N.E. 105St. Miami Shores, FI. 33138 Charles C. Mitchell, I.E. 924 N. Federal Hwy. Hollywood, FI. 33023 Civil /Structural #11127 305 - 336 -5069 "Roof Mitigation" I Charles Mitchell, attest that to the best of my knowledge the structure of the property meet code in all of the following explained in detail as follows: Code: FBC 2007 Dear Building Official, Roof: The Nuvue NVRT 24 uplift strap tie wrapped around the truss with 9 - 1/4" diameter tapcon screws to the concrete beam and 7- 16d nails to the truss is sufficient to secure and prevent uplift on the roof. Sincerly, 1g., Charles Mitchell, P.E. AN 3: BUILDING CODE COMPLIANCE OFFICE (BCCO) ° ®° ®... ° PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Nu -Vue Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCPRC reserves the right to revoke this acceptance, if it is determined by Miami -Dade county Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series NVTA, NVTAS, NVBH, NVUH, NVRT and NVTH Wood Connectors. APPROVAL DOCUMENT: Drawing No. NU -2, sheets 1 through 4, titled "NVTA and NVTAS, NVBH 24 and NVUH, NVRT and NVTH ", dated 02/13/03, with last revision on 07/19/06, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance (NOA) number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 05- 0701.04 and consists of this page 1 and evidence pages El and E2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING ° ° 140' WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.miamidade.gov/buildingcode NOA No: 08-0326.11 Expiration Date: August 21, 2013 Approval Date: May 22, 2008 Page 1 ft2/og / JCL, Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. NU -2, sheets 1 through 4, titled "NVTA and NVTAS, NVBH 24 and NVUH, NVRT and NVTH", dated 02/13/03 with last revision on 07/19/06, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E. "Submitted under NOA No. 05- 0701.04" B. TEST Test reports on wood connectors per ASTM D1761 by Product Testing, Inc., signed and sealed by C. R. Caudel, P.E. and S. E. Black, P.E. Report No. Wood Connector Direction Date 1. PT 02 -4073 NVTA Upward 11/06/02 2. PT 02 -4075 NVTA Upward 11/07/02 3. PT 02 -4074 NVTA Upward 11/06/02 4. PT 02 -3938 NVTA Upward 08/06/02 5. PT 03 -4177 NVRT36 Upward 02/03/03 6. PT 03 -4202 NVRT36 -T Upward 02/19/03 7. PT 03 -4271 NVRT36 -T Upward 03/27/03 8. PT 03 -4270 NVRT24 -T Upward 03/27/03 9. PT 02 -4095 NVUH26 Up & Downward 01/17/03 10. PT 02 -4096 NVBH24 Up &Downward 12/03/02 11. 31- 22456.0002 NVTA & NVTAS Lateral 07/06/02 12. PT 04 -4698 NVTH24 Upward Parallel/Perpendicular 04/15/04 13. PT 04 -5036 . NVTH24 Upward Load 12/10/04 C. CALCULATIONS Report of Design Capacities prepared by V. Product Model No. of Pages 1. NVBM24 7 through 8 2. NVRT 9 through 14 3. NVTA & NVTAS 1 through 6 4. NVTA & NVTAS 1 through 14 5. NVRT 15 through 15 "Submitted under NOA No. 04- 1202.01" N. Tolat, P.E. Date 05/05/03 05/05/03 05/05/03 02/06/03 07/07/03 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). Signature V. N. Tolat, P.E V. N. Tolat, P.E. V. N. Tolat, P.E. V. N. Tolat, P.E. V. N. Tolat, P.E. Myrr,•' 5 /2/o arios M. Utrera, P.E. Product Control Examiner NOA No: 08- 0326.11 Expiration Date: August 21, 2013 Approval Date: May 22, 2008 E -1 Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED EMATERIAL CERTIFICATIONS E. STATEMENTS 1. No Financial Interest and code compliance letter issued by Vipin N. Tolat, P.E., on 03/26/03 signed and sealed by V. N. Tolat, P.E. "Submitted under NOA No. 04-1202.01" 2. Letter to Nu -Vue Industries issued by Building Code Compliance Office on 08/10/04 and signed by C. F. Font, P.E. "Submitted under NOA No. 04-1202.01" G. OTHER 1. Notice of Acceptance No. 08- 0326.11, issued to Nu -Vue Industries, Inc., approved on 09/14/06 and expiring on 08/21/08. E -2 6g Carlos M. Utrera, P.E. Product Control Examiner NOA No: 08-0326.11 Expiration Date: August 21, 2013 Approval Date: May 22, 2008 TABLE 1 Truss Anchors NVTA and Riveted Truss Anchors with Seat NVTAS H Length (!n) Product Code Gauge seat Gauge strap 16 NVTA -16 NVTAS 212 20 14 18 NVTA -18 NVTAS 214 20 14 20 NVTA -20 NVTAS 216 20 14 22 NVTA -22 NVTAS 218 20 14 24 NVTA -24 NVTAS 220 20 14 26 NVTA -26 NVTAS 222 20 14 28 NVTA -28 NVTAS 224 20 14 30 NVTA -30 NVTAS 226 20 14 36 NVTA -36 NVTAS 232 20 14 48 NVTA -48 NVTAS 244 20 14 General Notes: No. of Fasteners each strap 10d Maximum Allowable Load (lbs) Uplift Single Strap Uplift Double NVTA L1 Single & Double Straps L2 Single & Double Straps 5 757 1514 250 500 6 805 1610 250 500 7 854 1708 250 500 8 902 *1804 250 500 9 951 *1902 250 500 10 999 *1998 250 500 11 1048 *2096 250 500 12 1096 *2192 250 500 13 1145 *2290 250 500 14 1193 *2290 250 500 *Note: For 8 or more nails per strap, use double truss for double straps. 1. Steel shall conform to ASTM A653. structural grade 33 (Min. yield 33 kW) and a minimum galvanized coating of 0 60 per ASTM A525. 2. Allowable loads are based on National Desing specifications (NDS) for wood construction, 2001 Edition and Florida Building Code 2004. 3. Design loads are for Southem Pine species with a specific gravity of 0.55. Allowable loads for other species shall be adjusted accordingly. 4. Nail values ore based on NDS table 11P, G =0.55 for common wire nails and have been reduced for Penetration Depth factor C.D. 5. Allowable Toads for wind uplift have already been increased by a duration factor of 1.6 for anchor nails. 33% steel stress increase is not used in the tabulated values. 6. Allowable loads for more than one direction for a single connection cannot be added together. A design Toad which can be divided into components in the directions given must ub�e evaluated as follows: p I� All a Uplift + Allow e t1 + AUoti �e L2 <= 1.0 7. Allowable Toads are based on 11" thick wood members unless otherwise noted. 8. All tie beams and grouted concrete masonry shall comply with chapters 19 and 21 of 2004 FBC. Concrete for tie beams and grout and mortar for concrete masonry shall be a min. of 2500 psi. Concrete masonry shall comply with ASTM c90. 9. Ail tests have been conducted in accordance with ASTM 0 -1761. 1" TABLE 2 Truss Anchors NVTA and Riveted Truss Anchors with Seat NVTAS H Length (in) Product Code Gauge seat Gauge strap 16 NVTA -16 NVTAS 212 20 14 18 NVTA -18 NVTAS 214 20 14 20 NVTA -20 NVTAS 216 20 14 22 NVTA -22 NVTAS 218 20 14 24 NVTA -24 NVTAS 220 20 14 26 NVTA -26 NVTAS 222 20 14 28 NVTA -28 NVTAS 224 20 14 30 NVTA -30 NVTAS 226 20 14 36 NVTA -36 NVTAS 232 20 14 48 NVTA -48 NVTAS 244 20 14 Perpendicular to wall L2 No. of Fasteners each strap 10d x 1.5" Maximum Allowable Load (lbs) Uplift Single Strap Uplift Double Stm�s1 CNVT,�� L1 Single & Double Straps 1.2 Single & Double Straps 5 1032 2236 250 500 6 1127 2254 385 565 7 1136 2272 520 630 8 1144 *2288 520 630 9 1153 *2306 520 630 10 1161 *2322 520 630 11 1170 *2340 520 630 12 1178 *2356 520 630 13 1187 *2374 520 630 *Note: For 8 or more nails per strap, use double truss for double straps. MODUCUREVISOD asspreM1bAdis 1. b4 Reinforcements Required Parallel to wall 1 VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 ' - Concrete Tie Beam or Tie Beam formed with concrete filled mosornIODUCTREIsIEWEID 2" 0 0 0 1 " 23" o —�-- Holes Dia. it" NVTA, NVTAS u—Vue Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 PHONE (305) 694 -0397 FAX: (305) 694 -0398 NVTA AND NVTAS TRUSS ANCHORS DWG #: NU --2 Sheet: 1 of 4 Date: FEB. 13, 2003 Revisions: July 7, 2003 June 15, 2005 Jan. 10, 2006 July 19. 2006 TABLE 3 NVBH 24 BUTTERFLY HANGER Notes: 1. Use all specified fasteners in schedule to achieve values indicated 2. Values are based on 1" header and Joist thickness. 3. See General Notes, Sheet 1. SYMM.(.' Mid Span DOWNWARD LOAD TABLE 4 NVUH 26 JOIST HANGER PRODUCT CODE GAUGE FASTENER SCHEDULE ALLOWABLE LOADS (Ibs.) 9 o (n-0 x PRO[ CC DOWNWARD GRAVITY LOADS 2x4 NVBH24 18 12 6 1113 Notes: 1. Use all specified fasteners in schedule to achieve values indicated 2. Values are based on 1" header and Joist thickness. 3. See General Notes, Sheet 1. SYMM.(.' Mid Span DOWNWARD LOAD TABLE 4 NVUH 26 JOIST HANGER Notes: 1. Use all specified fasteners in schedule to achieve values indicated. 2. Values are based on 3" header thickness and 1 r Joist thickness. 3. See General Notes, Sheet 1. VIP1N N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 SYMM. Mid Span DOWNWARD LOAD P>< ODUCc RUNEWBD ceuziOarb Me WNW Aoaptssoe No G8- ' r • i• 1 I1,1I 4fj1�' Part Control Nu V u e Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 PHONE: (305) 694 -0397 FAX: (305) 694 -0398 NVBH 24 AND NWH 26 HANGERS DWG #: Sheet: Date: Revisions: July 7, 2003 June 15, 2005 NU-2 2 of 4 FEB. 13, 2003 Jan. 10, 2006 July 19, 2006 GAUGE 1 FASTENER SCHEDULE ALLOWABLE LOADS (Ibs.) Sli PRO[ CC oo X DOWNWARD NAND UPLIFT .1.15Z= x 3 ; -3 GRAVITY LOADS LOAD 2x6 NVUH26 14 20 10 2233 1213 Notes: 1. Use all specified fasteners in schedule to achieve values indicated. 2. Values are based on 3" header thickness and 1 r Joist thickness. 3. See General Notes, Sheet 1. VIP1N N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 SYMM. Mid Span DOWNWARD LOAD P>< ODUCc RUNEWBD ceuziOarb Me WNW Aoaptssoe No G8- ' r • i• 1 I1,1I 4fj1�' Part Control Nu V u e Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 PHONE: (305) 694 -0397 FAX: (305) 694 -0398 NVBH 24 AND NWH 26 HANGERS DWG #: Sheet: Date: Revisions: July 7, 2003 June 15, 2005 NU-2 2 of 4 FEB. 13, 2003 Jan. 10, 2006 July 19, 2006 TABLE 5 NVRT Flat and Twisted Rafter Ties Length (in) Product Code Gauge 12 NVRT -12 14 16 NVRT -16 14 18 NVRT -18 14 20 NVRT -20 14 22 NVRT -22 14 24 NVRT -24 14 30 NVRT -30 14 36 NVRT -36 14 48 NVRT -48 14 16d Fasteners Maximum Up ift Load (Ibs) TOTAL n;eger* Flat Ties Twisted Ties 8 4 725 724 10 5 861 860 12 6 998 996 14 7 1135 1132 Notes: 1. Specify "F" for Flat and "T" for Twisted when ordering. 2. Fastener values are based on a minimum 1" thick wood members. 3. * Indicates no. of naffs in each connected wood member. 4. See General Notes, sheet 1. TABLE 6 NVRT Twisted Rafter Ties to Concrete Tie Beams or Concrete Filled Masonry Length (in) Product Code Gauge 12 NVRT -12 14 16 NVRT -16 14 18 NVRT -18 14 20 NVRT-20 14 22 NVRT -22 14 24 NVRT -24 14 30 NVRT-30 14 36 NVRT -36 14 48 NVRT - -48 14 Notes: No. of 16d nails to Wood Framing No. of is diameter Tapcons to Concrete Maximum Uplift Load (Ibs) 4 6 722 5 7 856 6 8 991 7 9 1125 PROLucr RENEWED comitybe wits the Thai Dandiseede Aooap No 1 . -,.7F1 y rr !Mier 1. ITW topcons shall be embedded a minimum of 1i" into concrete tiebeam or tiebeam formed with concrete filled masonry. ITW topcons shalt have a min. edge distance of 23" and minimum spacing of 13" as shown. 2. See General Notes, sheet 1. UPLIFT 3. All tapcons must be in the same row space at 11i" on centers. Do not use holes in the opposite row. Strap must be long enough to accommodate required tapcons. `b s s s s s o s s s s Al. .A •'.:•r" s s s s s s s e s s s a1 l :..; ...:. :;.:• ► VIPIN N. TOLAT, PE (CIVIL) LENGTH FL REG. 12847 ') 15123 LANTERN CREEK LANE 11:...... HOUSTON, TX 77068 HALF HALF t E\ u Y u e Industries, Inc. Reinforcement required i739....fie: 0 o - -4- NVRT Anchor Holes dia. /I" Do not Use circled holes 14" Connected Connected to truss to wall LENGTH Tie Beam formed with concrete filled masonary or concrete tie beam 1053 -1059 Eost 29 Street Hialeah, Florida 33013 PHONE: (305) 694 -0397 FAX: (305) 694 -0398 NVRT FLAT AND TWISTED RAFTER TIES DWG #: Sheet: Dote: Revisions: July 7, 2003 June 15, 2005 NU-2 3 of 4 Fa. 13, 2003 Jan. 10, 2006 July 19, 2006 • slot 0.203'x 1" .61.114: Truss plate required to transfer load to bottom chord NVTH Truss plate required to transfer load to bottom chord Reinforcements Required 011 Double StraP Double Truss Concrete Tie Beam or Tie Beam formed with concrete filled masonry Single Strap Single Truss Concrete Tie Beam or Tie Beam formed with concrete filled masonry 5 Nails in Front (Min.) Nails tOd x 1.5" illod0ri MespnaceiNo. 0,,; 'd Elspbeirsi . ,SAIL: Nails on Front & Back Shall be off centered TABLE 7 Truss Anchors NVTH H Length (in) Product Code Gouge seat Gauge strap 12 NVTH -16 18 14 14 NYTH -18 18 14 16 NVTH-20 18 14 18 NVTH -22 18 14 20 NVTH -24 18 14 22 NVTH-26 18 14 24 NVTH -28 18 14 26 NYTH -30 18 14 32 NYTH -36 18 14 44 NVTH-48 18 14 VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 No. of Fasteners in each Strap 10d x 1.5" Maximum Uplift Loads (ibs) Single Strap Double Straps on on Single Truss Double Truss 1032 2064 1222 2444 7 1275 2550 8 1329 2658 9 1383 2766 10 • 1437 2874 11 1490 2980 12 1544 3088 13 1598 3196 NVTH N u' Vu e Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 Phone: (305) 694 -0397 Fax: (305) 694 -0398 NVTH ANCHORS DWG #: Sheet: Date: NU-2 4 of 4 JULY 19, 2006. Revisions: