RF-12-1577Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 177619 Permit Number: RF -8 -12 -1577 Scheduled Inspection Date: August 23, 2012 Inspector: Rodriguez, Jorge Owner: WEST CONDOMINIUM INC, SHORES DI A Job Address: 9120 A7 NE 8 Avenue BLDG G Miami Shores, FL 33138 -0000 Project: <NONE> Contractor: ALL CONSTRUCTION & DEVELOPERS INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 113206044001 Phone: (786)768 -4330 Building Department Comments TILE ROOF REPAIR Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. August 23, 2012 For Inspections please call: (305)762 -4949 Page 17 of 31 CotANDI DING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: BUILDING JOB ADDRESS: 0 1�6� v '` City: Miami Shores Folio/Parcel#: Is the SIIRRUIZ Hlstorkally Dedgnateth Yes NO � A s we County: iami Da4e ?tip: ,,.; ` ...— FBC o Permit No. Master Permit No. 12� OWNER: Name (Fp Simple Titleholder) 1 a ICS Address:,_„-,/ 4 N [ ,5-1-re City: Nk t,!'4 M ' C re 5 , State: 3 13$ Tenant/Lessee Name: : Email: Phone#• . EAST 06G CONTRACTOR: Company Name: Address: r City: oO Qualifier Name: you fl O 1 CORStrWCio Phone#: Phone#: State Certification or 'stration #: Certificate of Competency it: Contact Phone#: d ti.ti Email Address: DESIGNER: Architect/Engineer: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: OAddition t]Alteration CINea, °�- air/Replace CiDeznolition Phone#: 49 Descripdon of Work: I ( F r ' : ;' r Color thru tile: ******** * * * * * * * * * * * * * * * * * * *** *** * * * * * ** gees********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** t.4 .: Permit Fee $ a Submittal Fee $ _ CCF $ Scanning Fee $ CO /CC $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee Double Fee $ Structural Review $ f TOTAL FEE NOW DUE $ ** Bonding Company's Name (if app . le) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or Ineallation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES,;BQILERS, HEATERS, TANKS and AIR CONDITIONERS; FTC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR _ _ PAYING TwKit FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND 10' OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature 7-\ Owner or Agent Signature Contractor The fore oing ' ', ent was acknowledged before me this `f% yb The going instrument was acknowl before me this day of �.. � . �- 20 I? , by P4bEd r C�Or 2AL E , day of d arl, 20 _, by 8,u e) evrrc� ersonally known to me ar who has produced who is personally known to me or who has produced r--� As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC• * * * * * * * * * ** * * * * * * * * * **** ** Y PUB Sign: Print My Co 1,1 - e Florida • y Comm. Expires Oct 26. 2014 , 'r� +`''� �' Commission # EE 37821 ,��6ni ,O'' Bonded Through National Notary Assn ******************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * ** Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06/10/2009XRevised 3/15/09) Ike Shores Plaza East Condominium Association, Inc. 745 North East 91d Street Miami Shores, FL 33138 305 -759 -9069 / FAX 305 - 759 -2101 E-MAIL spp123Qatt.net August 10, 2012 Miami Shores Village Building Dept. 10050 NE 2nd Avenue Miami Shores, FL 33138 Dear Sir / Madam: C 1-771 AUG 20201 This letter will serve as your confirmation that "All Construction" has been contracted and is authorized by the Board of Directors of the Shores Plaza East Condominium Association to perform roof repairs at building 9120 NE 8th Avenue, Miami Shores, Fla. Area of back entrance / overhang. Should you have any questions regarding the enclosed, please feel free to contact the condominium office. Sincerely yours, J.T4i Robert Gonzalez President cc: file ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 1 %''L Florida Building Code Editior High,VeIocity Hurricane Zone Uniform Permit Apfiicafign F-4Lrm-T APPROVED M ,arni Shores Village BY 9 �/ I 0 CC:P,IPI 1r1NCE V ri- ALL FEDERAL 3 °' Section A (General informati)rl) T Master Permit No. Contractor's Name f'F 1 n Job Address ��� 1 12.0 ❑ Low Slope ❑ Asphaltic Shingles ❑ New Roof Low slope Roof Area (SF) Process No. 1 CDn r ructiOr NBC -P'' HOOF CATEGORY ❑ Mechanically Fastened Tile 1 MortadAdhesive Set Tile ❑ Metal Panel/ShIngtes 0 Wood Shingles/Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ Reroofing ❑ Recovering Xnepair ROOF SYSTEM INFORMATION ❑ Maintenance Steep S �.! Roof Any SF Total (SF) CIP r 0-061,h- Section B (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.32 *ND Ei S\ is "_7x- r\NICr FLORIDA BUILDING CODE — BUILDING ote sitores Taut sot condominium Associatiot. Inc, 745 North East 9111 Street Omni Shores, FL 33138 30Thimeli saimm9759-1stith - VoloolFax 17 15 15 2 3 3.3 4 $2 5 3,0 7 Parking '14 ft-t- PArkingt LJ 910 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High - velocity Hurricane Zone Uniform Permit Application Fonn, Section D (Steep Sloped Roof System) Roof System Manufacturer:LQ r Tj ( e Notice of Acceptance Number:1 Q_ owl e O� Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): P3: P1: P2: Maximum Design Pressure (From Product Approval Specific System): 1 Rcf Slope: ,_) :12 Steep Sloped Roof System Description Deck Type: 1 i iOOb I x e� Type Underlayment: Ridge Vntifa ion? Insulation: ASTnl ft IT I t J/4 Fire Barrier: 11I 1 j Mean Roof Height It Fastener Type & Spacing: Adhesive Type: 44 r. s. wen 14fi -nncaPS 1 re, =: -i01.1 1-Winn Type Cap Sheet I4)N aG 5 5 P1 W3 I Roof Covering: laybri Cera .) cj Type & Size Drip \ Edge: IA P► 15.34 FLORIDA BUILDING CODE — BUILDING Kips MIAMI.GADE) COUNTY DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.m iamidade.gov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA # 11- 0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 ,sg i of 8 ROOFING COMPONENT APPROVAL Category: - Sub - Category: Material: Roofing Underlayment SBS , APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Surface Printing) Manufacturing Location #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 60 mils thick Roll: 32'10" x 3'33/8' 100 mils thick Roll: 65' x 3'33/8' 80 mils thick Roll: 32'10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofmg membrane, glass fiber reinforced with polyolefmic film on the upper surface for use as an underlayment for metal roofmg, roof tile, slate tiles and shingle underlayment. TAS 103 and A fine granular /sand top surface self - adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self-adhering, glass - fiber /polyester reinforced waterproofmg membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofmg membrane, glass- fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self-adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofmg and roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofmg membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA . 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. MIAMI -DADE COUNTY APPROVED Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 PRI01111 PUSA- 005 -02 -01 PUSA - 018 -02 -01 PUSA- 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Renort TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103 /ASTM D4798 & G155 TAS 110 /ASTM D4798 & D1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 3 at 8 INSTALLATION PROCEDURES: • Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-1/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04 /05/12 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS IR Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick 115, TU Plus, and Tile Pro may be used in both adhesive set and mechanically fastened roof file applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. a. 0 Roof Deck prey with POLNS ICK'N Plus 6 Roofing files (6 Max. Per Static) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MANMADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 6 of 8 • POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. MIAMI -DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. - 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofmg Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 8 of 8 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Lamoti Roof Tile, Inc. 1390 NW 29 Street Miami, FL. 33142 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barrel High Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 1214.07 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. MIAMI-DADE COUNTY APPROVED NOA No.: 12- 0207.02 Expiration Date: 03/14/17 Approval Date: 05-/31/12 Page 1 of 5 -ROOFING ASSEMBLY Category: Sub - Category: Material: APPROVAL Roofing High Profile Roofing Tiles Concrete 1. SCOPE This renews a roofing system using Lamoti Barrel High Profile Concrete Tile, as manufactured by Lamoti Roof Tile, described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code. For the locations where the pressure requirements, as determined by applicable building code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachement calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barrel Concrete Tile Trim Pieces Length : 18" TAS 112 High profile, two piece, concrete roof tile. For Width : 8 3/4' direct deck, adhesive set applications only. Thickness : 1 /z" 1= varies w = varies varying thickness 2. 1 PRODUCT DESCRIPTION 1. Miami, FL. 2.2 SUBMITTED EVIDENCE: Test Agency IBA Consultants, Inc. American Test Labs of South Florida TAS 112 Test Identifier 2358 -54 RT0511.02 -12 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report TAS -101 TAS -112 Date 05/08/07 05/16/12 NOA No.: 12- 0207.02 Expiration Date: 03/14/17 Approval Date: 05/31/12 Page 2 of 5 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofmg Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 2 ":12" to 7 ":12" 4. INSTALLATION 4.1 Lamoti `Barrel high Profile Concrete Tile' and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Barrel High Profile Concrete Tile 8.1 1.50 0.73 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Table 2: Aerodynamic Multipliers - A, (ft3) Tile Profile 3 ":12" A, (ft3) Batten Application A, (ft3) Direct Deck Application Barrel High Profile Concrete Tile Greater than 7 ":12" N/A 0.23 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 2 ":12" 3 ":12" 4 ":12" 5 ":12" 6 ":12" Greater than 7 ":12" Barrel High Profile Concrete Tile Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck 5.66 5.56 5.43 5.25 5.01 4.72 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barrel High Profile Concrete Tile Polyfoam Polypro AH 160T"' 77.871 1 Paddy placement of 37 grams of Polypro AH 160T"' for pan tile, 17.5 grams on each side for cap tiles. NOA No.: 12- 0207.02 Expiration Date: 03/14/17 Approval Date: 05/31/12 Page 3 of 5 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". LRT LAMOTI BARREL CONCRETE TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI DADE COUNTY APPROVED NOA No.: 12- 0207.02 Expiration Date: 03/14/17 Approval Date: 05/31/12 Page 4 of 5 7„ PROFILE DRAWINGS 2" 18" 8.75" MIAMIOADE COUNTY APPROVED 8.75" 8.75" LAMOTI ROOF TILE "BARREL CONCRETE TILE" END OF THIS ACCEPTANCE 1 1 1 18" t NOA No.: 12- 0207.02 Expiration Date: 03/14/17 Approval Date: 05/31/12 Page 5 of 5