RF-12-1577Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 177619 Permit Number: RF -8 -12 -1577
Scheduled Inspection Date: August 23, 2012
Inspector: Rodriguez, Jorge
Owner: WEST CONDOMINIUM INC, SHORES
DI A
Job Address: 9120 A7 NE 8 Avenue BLDG G
Miami Shores, FL 33138 -0000
Project: <NONE>
Contractor: ALL CONSTRUCTION & DEVELOPERS INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Repair Roof
Phone Number
Parcel Number 113206044001
Phone: (786)768 -4330
Building Department Comments
TILE ROOF REPAIR
Inspector Comments
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
August 23, 2012
For Inspections please call: (305)762 -4949
Page 17 of 31
CotANDI
DING
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
Permit Type: BUILDING
JOB ADDRESS: 0 1�6� v '`
City: Miami Shores
Folio/Parcel#:
Is the SIIRRUIZ Hlstorkally Dedgnateth Yes
NO
� A s
we
County: iami Da4e ?tip: ,,.; ` ...—
FBC o
Permit No.
Master Permit No. 12�
OWNER: Name (Fp Simple Titleholder) 1 a ICS
Address:,_„-,/ 4 N [ ,5-1-re
City: Nk t,!'4 M ' C re 5 , State: 3 13$
Tenant/Lessee Name: :
Email: Phone#• .
EAST
06G
CONTRACTOR: Company Name:
Address: r
City: oO
Qualifier Name: you fl O
1
CORStrWCio
Phone#:
Phone#:
State Certification or 'stration #: Certificate of Competency it:
Contact Phone#: d ti.ti Email Address:
DESIGNER: Architect/Engineer:
Value of Work for this Permit: $
Square/Linear Footage of Work:
Type of Work: OAddition t]Alteration CINea, °�- air/Replace CiDeznolition
Phone#:
49
Descripdon of Work: I ( F r ' : ;' r
Color thru tile:
******** * * * * * * * * * * * * * * * * * * *** *** * * * * * ** gees********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
t.4
.: Permit Fee $
a
Submittal Fee $ _ CCF $
Scanning Fee $ CO /CC $
Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee
Double Fee $ Structural Review $
f
TOTAL FEE NOW DUE $
**
Bonding Company's Name (if app . le)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or Ineallation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES,;BQILERS, HEATERS, TANKS and AIR CONDITIONERS; FTC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR _ _ PAYING TwKit FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND 10' OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged
Signature
7-\
Owner or Agent
Signature
Contractor
The fore oing ' ', ent was acknowledged before me this `f% yb The going instrument was acknowl before me this
day of �.. � . �- 20 I? , by P4bEd r C�Or 2AL E , day of d arl, 20 _, by 8,u e) evrrc�
ersonally known to me ar who has produced who is personally known to me or who has produced
r--� As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC•
* * * * * * * * * ** * * * * * * * * * **** **
Y PUB
Sign:
Print
My Co
1,1 - e Florida
• y Comm. Expires Oct 26. 2014
,
'r� +`''� �' Commission # EE 37821
,��6ni ,O''
Bonded Through National Notary Assn
******************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
* * **
Structural Review Clerk
(Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06/10/2009XRevised 3/15/09)
Ike Shores Plaza East Condominium Association, Inc.
745 North East 91d Street
Miami Shores, FL 33138
305 -759 -9069 / FAX 305 - 759 -2101
E-MAIL spp123Qatt.net
August 10, 2012
Miami Shores Village
Building Dept.
10050 NE 2nd Avenue
Miami Shores, FL 33138
Dear Sir / Madam:
C 1-771
AUG 20201
This letter will serve as your confirmation that "All Construction" has been
contracted and is authorized by the Board of Directors of the Shores Plaza
East Condominium Association to perform roof repairs at building 9120 NE
8th Avenue, Miami Shores, Fla. Area of back entrance / overhang.
Should you have any questions regarding the enclosed, please feel free to
contact the condominium office.
Sincerely yours,
J.T4i
Robert Gonzalez
President
cc: file
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
1
%''L Florida Building Code Editior
High,VeIocity Hurricane Zone Uniform Permit Apfiicafign F-4Lrm-T
APPROVED
M ,arni Shores Village
BY
9 �/ I 0 CC:P,IPI 1r1NCE V ri- ALL FEDERAL
3 °' Section A (General informati)rl) T
Master Permit No.
Contractor's Name f'F 1
n
Job Address ��� 1 12.0
❑ Low Slope
❑ Asphaltic
Shingles
❑ New Roof
Low slope Roof Area (SF)
Process No.
1 CDn r ructiOr
NBC -P''
HOOF CATEGORY
❑ Mechanically Fastened Tile 1 MortadAdhesive Set Tile
❑ Metal Panel/ShIngtes 0 Wood Shingles/Shakes
❑ Prescriptive BUR -RAS 150
ROOF TYPE
❑ Reroofing ❑ Recovering Xnepair
ROOF SYSTEM
INFORMATION
❑ Maintenance
Steep S
�.! Roof Any SF Total (SF)
CIP r
0-061,h-
Section B (Roof Plan)
Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets.
15.32
*ND Ei S\ is
"_7x-
r\NICr
FLORIDA BUILDING CODE — BUILDING
ote sitores Taut sot condominium Associatiot. Inc,
745 North East 9111 Street
Omni Shores, FL 33138
30Thimeli saimm9759-1stith - VoloolFax
17
15
15 2
3
3.3 4
$2 5
3,0 7
Parking
'14
ft-t-
PArkingt
LJ
910
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2004
High - velocity Hurricane Zone Uniform Permit Application Fonn,
Section D (Steep Sloped Roof System)
Roof System Manufacturer:LQ r Tj ( e
Notice of Acceptance Number:1 Q_ owl e O�
Minimum Design Wind Pressures, if Applicable (From RAS 127 or
Calculations): P3:
P1: P2:
Maximum Design Pressure
(From Product Approval Specific System):
1 Rcf Slope:
,_) :12
Steep Sloped Roof System Description
Deck Type:
1 i iOOb I x e�
Type Underlayment:
Ridge Vntifa ion?
Insulation:
ASTnl ft IT
I t J/4
Fire Barrier: 11I 1 j
Mean Roof Height
It
Fastener Type & Spacing:
Adhesive Type:
44 r. s. wen 14fi -nncaPS
1 re, =:
-i01.1 1-Winn
Type Cap Sheet I4)N aG 5 5 P1 W3 I
Roof Covering: laybri Cera .) cj
Type & Size Drip
\ Edge:
IA
P►
15.34
FLORIDA BUILDING CODE — BUILDING
Kips
MIAMI.GADE)
COUNTY
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.m iamidade.gov /pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the
right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA # 11- 0601.10 and consists of pages 1 through 8
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
,sg i of 8
ROOFING COMPONENT APPROVAL
Category:
- Sub - Category:
Material:
Roofing
Underlayment
SBS , APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick MTS
underlayment
Manufacturing Location
#2
Polystick IR Xe
underlayment
Manufacturing Location
#1 & #2
Polystick TU
underlayment
Manufacturing Location
#1 & #2
Polystick TU Plus
underlayment
(Surface Printing)
Manufacturing Location
#2
Polystick TU P
underlayment
Manufacturing Location
#2
Polystick Tile Pro
Manufacturing Location
#2
Polystick Dual Pro
Manufacturing Location
#2
Dimensions
Roll:
65'8" x 3'3-3/8"
60 mils thick
Roll:
65' x 3'33/8"
Or 65' x 3'
60 mils thick
Roll:
32'10" x 3'33/8'
100 mils thick
Roll:
65' x 3'33/8'
80 mils thick
Roll:
32'10" x 3'33/8"
130 mils thick
Roll:
61' x 3'33/8"
60 mils thick
Roll:
61' x 3'33/8"
60 mils thick
Test Product
Specification Description
TAS 103 A homogeneous, rubberized asphalt
waterproofmg membrane, glass fiber reinforced
with polyolefmic film on the upper surface for
use as an underlayment for metal roofmg, roof
tile, slate tiles and shingle underlayment.
TAS 103 and A fine granular /sand top surface self - adhering,
ASTM D 1970 APP polymer modified, fiberglass reinforced,
bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
A heavy granuled surface self adhering, APP
polymer modified, fiberglass or polyester
reinforced, bituminous sheet material for use as
an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
A rubberized asphalt self-adhering, glass -
fiber /polyester reinforced waterproofmg
membrane. Designed as a metal roofing and roof
tile underlayment.
A rubberized asphalt waterproofmg membrane,
glass- fiber /polyester reinforced, with a granular
surface designed for use as a tile roof
underlayment.
A rubberized asphalt self-adhering, glass -
fiber /polyester reinforced waterproofing
membrane. Designed as a metal roofmg and roof
tile underlayment.
A rubberized asphalt self - adhering, glass -
fiber /polyester reinforced waterproofmg
membrane. Designed as a metal roofing and
roof tile underlayment.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
. 2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency
Exterior Research & Design, LLC
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
MIAMI -DADE COUNTY
APPROVED
Test Identifier
11756.04.01 -1
11756.08.01 -1
02202.08.05
P5110.08.07
P10870.09.08 -R1
P10870.04.09
P33360.06.10
P33370.03.11
P33370.04.11
P36900.09.11
P37300.10.11
PRI01111
PUSA- 005 -02 -01
PUSA - 018 -02 -01
PUSA- 035 -02 -01
PUSA- 033 -02 -01
PUSA- 055 -02 -02
PUSA- 083 -02 -01
PUSA- 089 -02 -01
JX20H7A
RX14E8A
DX23D8B
DX23D8A
Test Name/Renort
TAS 103
ASTM D 1970
TAS 103
TAS 103
TAS 103
TAS 103 /ASTM D4798 & G155
ASTM D1970
TAS 103
ASTM D 1623
TAS 103 /ASTM D4798 & G155
TAS 110 /ASTM D4798 & D1970
ASTM D 4977
ASTM D 4977
ASTM D 2523
TAS 103
ASTM D 1970
TAS 103
TAS 103
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
Date
04/27/01
08/14/01
08/29/05
08/29/07
12/04/08
04/13/09
07/01/10
03/02/11
04/26/11
09/01/11
10/19/11
04/08/02
01/31/02
07/14/03
09/29/06
01/12/06
12/10/07
06/30/08
07/06/09
04/01/08
11/09/09
02/18/10
02/18/10
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 3 at 8
INSTALLATION PROCEDURES:
• Deck Type 1: Wood, non - insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self - adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-1/2" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04 /05/12
Page 4 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles,
non - structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be
used in all the previous assemblies listed except metal roofing.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations (days)
Polystick MTS
MTS
IR Xe
TU
TU Plus
TU P
Tile Pro
Dual Pro
Winter Haven, FL.
180
180
180
180
180
180
180
Hazelton, PA.
N/A
30
30
180
N/A
N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N -3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick 115, TU Plus, and Tile Pro may be used in both adhesive set
and mechanically fastened roof file applications. Polystick IR -Xe, and Dual Pro are limited to mechanically
fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile
applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Polystick IR -Xe
Polystick TU, TU
Plus, TU P, Tile Pro
Flat Tile
Prohibited without battens
5:12
No limitation
Profiled Tile
Prohibited without battens
Prohibited
No limitation
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
a.
0
Roof Deck prey with
POLNS ICK'N Plus
6
Roofing files
(6 Max. Per Static)
12
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro
may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR Xe, TU, TU
Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If
Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift
resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
MANMADE COUNTY
APPROVED
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 6 of 8
• POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back - nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"/12 ", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric
Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of
repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over
the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The
repair should be installed in such a way so that water will run parallel to or over the top of all laps of the
patch.
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894 -4563.
MIAMI -DADE COUNTY
APPROVED
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894 -4563.
- 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofmg Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
APPROVED
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 8 of 8
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Lamoti Roof Tile, Inc.
1390 NW 29 Street
Miami, FL. 33142
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.miamidade.gov /pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barrel High Profile Concrete Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 06- 1214.07 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
MIAMI-DADE COUNTY
APPROVED
NOA No.: 12- 0207.02
Expiration Date: 03/14/17
Approval Date: 05-/31/12
Page 1 of 5
-ROOFING ASSEMBLY
Category:
Sub - Category:
Material:
APPROVAL
Roofing
High Profile Roofing Tiles
Concrete
1. SCOPE
This renews a roofing system using Lamoti Barrel High Profile Concrete Tile, as manufactured by Lamoti Roof
Tile, described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code.
For the locations where the pressure requirements, as determined by applicable building code does not exceed
the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in
section 4 herein. The attachement calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Barrel Concrete Tile
Trim Pieces
Length : 18" TAS 112 High profile, two piece, concrete roof tile. For
Width : 8 3/4' direct deck, adhesive set applications only.
Thickness : 1 /z"
1= varies
w = varies
varying thickness
2. 1 PRODUCT DESCRIPTION
1. Miami, FL.
2.2 SUBMITTED EVIDENCE:
Test Agency
IBA Consultants, Inc.
American Test Labs of South
Florida
TAS 112
Test Identifier
2358 -54
RT0511.02 -12
Accessory trim, concrete roof pieces for use at hips,
rakes, ridges and valley terminations.
Manufactured for each tile profile.
Test Name/Report
TAS -101
TAS -112
Date
05/08/07
05/16/12
NOA No.: 12- 0207.02
Expiration Date: 03/14/17
Approval Date: 05/31/12
Page 2 of 5
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofmg Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 2 ":12" to 7 ":12"
4. INSTALLATION
4.1 Lamoti `Barrel high Profile Concrete Tile' and its components shall be installed in strict compliance with
Roofing Application Standard RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (1 x w )
Tile Profile
Weight -W (Ibf)
Length -I (ft)
Width -w (ft)
Barrel High Profile Concrete Tile
8.1
1.50
0.73
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Table 2: Aerodynamic Multipliers - A, (ft3)
Tile
Profile
3 ":12"
A, (ft3)
Batten Application
A, (ft3)
Direct Deck Application
Barrel High Profile Concrete Tile
Greater than
7 ":12"
N/A
0.23
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
2 ":12"
3 ":12"
4 ":12"
5 ":12"
6 ":12"
Greater than
7 ":12"
Barrel High
Profile
Concrete
Tile
Direct Deck
Direct Deck
Direct Deck
Direct Deck
Direct Deck
Direct Deck
5.66
5.56
5.43
5.25
5.01
4.72
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Barrel High Profile Concrete Tile
Polyfoam Polypro AH 160T"'
77.871
1 Paddy placement of 37 grams of Polypro AH 160T"' for pan tile, 17.5 grams on each side for cap tiles.
NOA No.: 12- 0207.02
Expiration Date: 03/14/17
Approval Date: 05/31/12
Page 3 of 5
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail
Below), or following statement: "Miami -Dade County Product Control Approved ".
LRT
LAMOTI BARREL CONCRETE TILE LABEL
(LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
MIAMI DADE COUNTY
APPROVED
NOA No.: 12- 0207.02
Expiration Date: 03/14/17
Approval Date: 05/31/12
Page 4 of 5
7„
PROFILE DRAWINGS
2"
18"
8.75"
MIAMIOADE COUNTY
APPROVED
8.75"
8.75"
LAMOTI ROOF TILE "BARREL CONCRETE TILE"
END OF THIS ACCEPTANCE
1
1
1
18"
t
NOA No.: 12- 0207.02
Expiration Date: 03/14/17
Approval Date: 05/31/12
Page 5 of 5