RF-12-1226
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 175417 Permit Number: RF -7 -12 -1226 Scheduled Inspection Date: August 08, 2012 Inspector: Bruhn, Norman Owner: WILLIAMSON, ROBERT Job Address: 1235 NE 96 Street Miami Shores, FL Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1132060143790 Phone: 305 - 757 -2612 Building Department Comments RE -ROOF REAR FLAT Inspector Comments Passe Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. August 07, 2012 For Inspections please call: (305)762 -4949 Page 11 of 33 t Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 lib INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILD G Permit No. ?,' 2 H Z2ee PERMIT APPLICATION Master Permit No. REC JUL 03 2012 B FBC 20 Permit Type: BUILDING ROOFING 1( p OWNER: Name (Fee Simple Titleholder): h A 4 W Lb v A K- S CM-- Phone#: �Q ('O -- td7,( Address: 1 3, L E / �i L{ , A' t, Shores City: idt t o i-e < S he YC) State: PI Zip: ? 31 3 8 Tenant/Lessee Name: Phone #:. Email:. �_. __.._... JOB ADDRESS: t' 3 l9 City: Folio/Parcel #: Miami Shores County: d v Is the Building Historically Designat + : Yes _ NO Miami Dade 1 zip: 12'30 ir Flood Zone: CONTRACTOR: Company Name: 69 '�'N B V✓I v nel Phon 0 Address: kck. U 4 Zip: City:t A c \Mj -1.5 State: Qualifier Name: €) D 'c i OL Phone #: �✓ 6 5-7S-7c2 CL ( � � 6 Certificate of Competency l State Certification or Registration #: ,c,(�C. petency #: d o0 co Gtr Contact Phone #: �d� �(.i �� �`° Email ddress: DESIGNER: Architect/Engineer: �✓ Phone#: Value of Work for this Permit: $ 0 t Square/Linear Footage of Work: Type of Work: ❑Additio °Alteration New �,epair/Replace Description of Work: r- 0 e& r I( 64 IL) ( VI Aeu.s T)-(-Cie-c( SZ," fi1 /f,UO °Demolition ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** gees************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee '� - � _ -' � .' ,- Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 2/1X` ®`�(� Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Oo The foregoing instrument was acknowledged before me this day of r,-.0, ° , 20 1. ,, by -uu -l° o� ,,�� r , who is personally known to me or who has produced Nc As identification and who did take an oath. NOTARY PUBLIC: Si Print: My Commission Exp Commission it 09 980055 Banta 11uoish NOW Noioy Assn. Contractor The foregoing instrument was acknowledged before me this day of .. , 20 L by e who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLI; : Sign: Print: My Commission Expires: .....,.• * *** * * * * * * ****** * * * ***** ** * ** ** * ** �x+ +x *x��xx��x *x� *+x * *x� ** *x� *x��x * *x� * * *+x* x�x�x� *+x * *�x�xx�+xw * ** *�x * *+x * ** k x�x�* `1 *\���` / ✓ r II I APPROVED BY f " / 7 v Plans Examiner Zoning Structural Review (Revised 07 /10/07)(Revised 06 /10/2009)(Revised 3/15/09) Clerk Miami Shores ViHage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: joe✓� ii74 fru 5,7 , c) Property Address: /-- 35- //,E- goo S r Roofing Permit Number: Dear Buil ing Official: 1.7 "--e r (474, So Al certify that 1 am not required to retrofit the roof to wall connections of my building because: o The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1 • edif.• ;•f the South Florida Building Code (1994 SFBC) 'wog Signature Print Name State of Florida County of Dade in r4 The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Swom to and subscribed before me this j day of T' , A bi Notary Public, Sate of Florida at Large • When the just valuation of the structure for purpose of ad valorem taxation Is equal to or more than $300, SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connect] n rricane itigation. Revised on 5/21/2009 994 CUMULATIVE SUBSTANTIAL IMPROVEMENT VERIFICATION WORK SHEET In accordance with FEMA regulation and Miami Shores Village Flood Damage Prevention Ordinance the costs of all improvements must be monitored. The costs of any improvements in the past 12 months and the costs of any proposed improvements must be shown on the worksheet. The cost of improvements must include demolition, raw and finished materials (include those donated), labor (including volunteer and self- performed), construction supervision and management, and overhead and profit. A list of items the costs of which are to be included as well as those excluded is attached for your reference. (A Copy of the Contract must be attached) PROPERTY OWNER: ' �o/l�- /!C' 571 PERMIT # L ADDRESS: /.)- 3 s /v / 9t 5 i /1 3206' 0/9 3790 FOLIO NUMBER: FLOOD ZONE: BASE FLOOD ELEVATION: FREEBOARD: EAST OF FL.CCCL: COST OF PAST IMPROVEMENTS (12 MONTHS): 5Q 0 0 COST OF PROPOSED IMPROVEMENTS: (ATTACH COPY OF CONTRACT) 3/000 It 11 %�n'lf�✓�'lJ TOTAL CUMULATIVE COST OF IMPROVEMENTS (past and proposed): Lb ` 0 VALUE OF PRINCIPAL STRUC ' (attac appraisal): 'f7i OWNERS SIGNATURE � I /1, / DATE: 5/1 /� PLANREVIEWER: PLAN REVIEWER SIGNATURE: DATE: c11- Created on June 2009 Miami -Dade My Home My Home Show Me: Property Information Search By: Select Item ■ Text only, Property Appraiser Tax Estimator Property Appraiser Tax Comparison 5/ Portability S.O.H. Calculator Summary Details: olio No.: 11- 3206 - 014 -3790 jT. 1235 NE 96 ST ailing ROBERT F WILLIAMSON JR ddress: W JULIE Living Units: 1235 NE 96 ST MIAMI FL Adj Sq Footage: 138 -2553 Property Information: Primary Zone: 1400 SINGLE FAMILY RESIDENCE CLUC: 0001 RESIDENTIAL - SINGLE FAMILY Beds/Baths: 4/3 Floors: 2 Living Units: 1 Adj Sq Footage: 2,741 Lot Size: 20,250 SQ FT Year Built: 1937 $50,000 / $203,517 5-6 53 42 MIAMI City: SHORES SEC 3 PB 10- Legal 37 LOT 8 9 &10 BLK 83 Description: LOT SIZE IRREGULAR OR 9749 -1620 OR 09749 -1620 0777 00 Assessment Information: • ACT! fE TOOL: SELECT Exemptlon Information: =MM. 2011 2010 _aTn� $231,710 $243,98• Gi it<•fi, • LEI mil $228,873 229,000 Market Value: $46',583 • 72,986 rr"MVPMMIEENEWAIIMMI $50,000/ $203,517 $50,000/ $199,771 Exemptlon Information: =MM. 2011 2010 �.4-;_.. $25,000 $25,000 9321 .11 ®® Exemption/ Taxable Taxable Value Information: Year: 2011 2010 Applied Applied Taxing Authority: Exemption/ Taxable Exemption/ Taxable Value: Value: Regional: $50,000/ $203,517 $50,000/ $199,771 County: $50,000 / $203,517 $50,000/ $199,771 City: $203,517 $203,517 $50,000/ $199,771 School Board: $25,000/ $228,517 $25,000/ $224,771 Sale Information: le Date: /1977 Aerial Photography - 2009 0 115 ft My Home 'Property Information 1 Property Taxes [My Neighborhood [Property Appraiser Home I Using Our Site 'Phone Directory [Privacy 1 Disclaimer If you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at Webmaster. Web Site © 2002 Miami -Dade County. All rights reserved. Page 1 of 2 MIAMhDADE Legend Property Boundary Selected Property Street Highway Miami -Dade County Water W+ s http: / /gisims2. miamidade .gov /myhome /propmap.asp 2/22/2012 HIGH - VELOCITY HURRICANE ZONES Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) 07 Process No. �''7 L - Master Permit No. Contractor's Name 04 R./b Let— /Z7© Job Address / 2 3_5 /V .5fAEQ—ir ,t ROOF CATEGORY 16. Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set 1ile ;' ^' ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes Shingles ❑ Prescriptive BUR -RAS 150 1 ROOF TYPE ❑ New Roof 6. Reroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 360 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains: Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. H?ERWHT P ER :, (' vfiami Shores Village APPROVED BY DATE ZONING DEPT ` --f BLDG DEPT SUBJECT 10 CCMPI.IAIttCEWTPri STATE AND CC ALL FEDEFIAI ' UN -, ( RULES AND REGULATIONS 2010 FLORIDA BUILDING CODE — RESIDENTIAL N 44.21 HIGH - VELOCITY HURRICANE ZONES Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Fill in Specific Roof Assembly Components and Identify Manufacturer (If a component is not used, identify as "NA ") Fastener Spacing for Anchor /Base Sheet Attachment AA Field: 7 " oc @ Lap, # Rows G @ 9 " oc System Manufacturer: Y 04-'G Perimeter: 6 " oc @ Lap, # Rows @ G " oc Corner: 6- oc @ Lap, # Rows 5---@ " oc NOA No.: 05 C 7 • pi Design Ind Pressures, From RAS 128 or Calculations: �jj�i� P1: a �/ P2: P3: ice..._'—' Max. Design Pressure, From the Specific NOA 52,.5' System: Deck: Type: l.J o o G{ Gauge/Thickness: 3/4 Slope: jet r Anchor /Base Sheet & No. of PIy(s): /1/4- Anchor /Base Sheet Fastener/Bonding Material: Insulation Base Layer: N/A - Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: /C /A. Top Insulation Size and Thickness: Top Insulation Fastener /Bonding Material: Number of Fasteners Per Insulation Board �v fr Field erimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers-Details that Comply with RAS 111 and Chapter 16. i Base Sheet(s) & No. of Ply(s): � frt t 14 S 7< Base Sr�e_e" et t� Ma 5A n A�`�� PIy Sheet(s) & No. of PIy(s):' /I 'd / c( t Fas er1 ond'y'��I�,a Top Ply: / n ' (C■• /70 F/L Top Ply Fastener/ Bpr)Qin2 Mat 4 v G � r�G Surfacing: �ioe� � FT. �jtly- co . S � re Parapet 0 A,*eW /, f °A �_> Heiaht /14 fse/teor I /0 Mean Roof Height 2010 FLORIDA BUILDING CODE — RESIDENTIAL SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contrac t The 'wner's initial in the designated space indicates that the item has been explained. 1. Aesthetics-Workmanship: the workmanship provisions of Section R4402 are for the purpose of irgV at the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of th • ree , ent between the owner and the contractor. Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be n accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior emoving the existing roof system). Common roofs: Common roofs are those which have no visible delineation between neighboring is (r., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be perforated. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can = r r'd from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the pearance. Ponding water: The current roof system and /or deck of the building may not drain well and may ater to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not aa d from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in ac . rdance with the requirements of Sections R4402, R4403 and R4413. 7. 1 Ventilation: Most roof structures should have some ability to vent natural airflow through the - or of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting ich can result in extending the service life of the Ys Signature Date Revised on 7/9/2009 LD ntractor Signature 59114 Date MIA M1OADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 07- 1203.01 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 1 of 31 Membrane Type: SBS /SBS Cold Applied Deck Type 1: Wood, Non-insulated Deck Description: 19 /n" or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield® Non-Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base sheet: GAFGLASa #80 ULTIMA TM Base Sheet, STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® SBS Heat- WeIdTM Smooth or RUBEROID® SBS Heat- WeldTM 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any Options: of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.S psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" DrilI-TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 27 of 31 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #77 Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #80, RUBEROID® MOP Smooth or RUBEROID® 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. Membrane: One or moreplies of RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID ®Mop Plus Granule, RUBEROID®20, RUBEROID ®30, RUBEROID®EnergyCap SBS 30 FR RUBEROID ®3 0 FR or RUBEROID® Mop FR or RUBEROID ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Or, One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID®20, RUBEROID® 30, RUBEROID®Energy, Cap SBS 30 FR, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID ULTRACLAD® SBS in Leak BusterTM Matrix"' 102 SBS Adhesive at an application rate of 1 -2 gal./sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsisq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak Buster"' MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak BusterTM MatrixTM303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCQAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. • 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galfsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above MIAMwoADE COUNTY APPROVED NOA No.: 09 -0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 28 of 31 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum ' /a" Dens Deck or ' /z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofmg Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 31 of 31 2067 ROOFING MATERIALS AND :1 SYTEMS>DIRECTORY 192 ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU) — Continued Base Coat: "A-38 Series", 0.75 gal /sq. Second Base Coat "A -3l3 Series ", 0.75 gal /sq. Wear Coat 7A -38 Series ", 0.75 gal /sq plus walnut shells at 0.751bs per sq. Surfacing: "A -38 Series ", 0.75 gal /sq plus walnut shells at 015.Ibs per 46 D k: NC Incline: 3/4 Foam: Spray application of 2 -in:. thick "Polyfoam 273" (2.7lb /ft.3 ) Surfacing: Spray application of 28 to 34 -mils "U -8730" (aluminum) 47 Deck: NC Incline: 1/2 Insulat application ) Surfacing: Spray application of 24 to 34 -mi b(1 -8782" (ivory) GAP A+f AItTALStORP R1306 1361 ALI'S RD, WAYNE NJ 07470- - "Ruberoid 20" or "Ruberoid Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G- P. Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in.. with the joints in the deck. If polystyrene is part of the roof system, it must be. placed below the overlayment board. Also, multiple plies of " GAFGLAS Ply 4" or "Ply 6" may be adhered to G -P Gypsum DensDeck® in hot asphalt. rgyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification. GAF Stratavent Eliminator Venting Base Sheet (Nailable)" may be mechani- cally attached or hot mopped over noncombustible decks and as a recover over existing roof systems. GAFGLAS Perlite Insulation may be utilized as a cover board over "EVER - GUARD" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane insulation adhesive. Polysty- rene reference in any of the following Classficatons include "ENERGuard PS Insulation ". References to glass fiber insulation include " EnergyGuard Fiberglass hisu- lation ". ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type Gl asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet" or " GAFGLAS #80 ULTIMA" ) is a suitable alternate for Type G1 asphalt halt glass fiber plysheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6" ) in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAF Stratavent Eliminator Venting Base Sheet (Perforated)" or "GAF Stratavent - Elininator° Venting Base Sheet ( Nailable)" . Perforated to be mopped and nailable to be mechanically attached granule side down. As an, option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base AS Sheet ", " GAFGL #80 UL or "GAF Stratavent Eliminator Venting Base Sheet (Nailable) " may be substituted for G1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or " GAFGLAS Ply 6" ) as the nailed base ply in the following ystems. Bottom ply or base sheet may be solid mopped, spot mopped or mechani- cally fastened. Unless otherwise indicated; affil insulations may be hot mopped or mechani- cally fastened. "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE ®" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems Listed. Structural 'cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B orC systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin paper (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the following Class A, B or C systems. "BMCA EnergyGuard RA ", "BMCA Tapered EnergyGuard RA" and "BMCA EnergyGuard RA" may be substituted for any Atlas polyisocyanurate insula- tion m any of the following Classifications. Trumbull "Perms Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". GAFGLAS 4180 Premium Base Sheet may be used in any of the following systems: °ate "GAFGLAS Flex Ply 6" is a suitable alternate to "GAFGLAS Ply 6 ". ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following.NC¢Classifications.: Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced. with "Piresbield MB" at Z5 3.0 gal /sq. Class Aril and; Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid Heat Weld" SBS roofing, membrane may by used in lieu of "Ruberoid Mop" SBS products in any applicable Classification. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped. Surfacing. Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): / One or more layers perlite, wood fiber, glass fiber, isocyariurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". 3. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood fiber / isocyanurate composite, phenolic, 2 in. max. Ply Sheet: Two or more layers Type G1.' "GAFGLAS Ply 4" or "GAF - GLAS Ply 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". 4. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. Ply Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. 5. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet One layer Type G2 "GAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet: One or more layers Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". Deck: NC Incline: 3 Base Sheet One layer Type G2 "GAFGLAS #75 Base Sheet ". Ply Sheet One or more layers Type GI " GAFGLAS Ply 4" or "GAF - GLAS Ply 6 ". Cap Sheet One layer Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". ' 7. Deck: C- 15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, phe- nolic, 1.0 in. min (offset from plywood joints 6in.). Base Sheet: One or more layers Type G1, G2 or G3, One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mbp" (Smooth or Granule) or "Ruberoid Mop Plus" (granule). Cap Sheet Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ", hot mopped. 8. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any is Base Sheet: Two or more layers Type G2 or G3. Ply Sheet (Optional): One or more layers Type G1. Membrane: One or more layers "Ruberoid Torch" (ooth or Granule), "Ruberoid Torch Plus ",(granule), "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop. Plus" (granule): LOOK FOR THE: Ul, MARK ON PRODUCT 2007:;ROOFING MATERIALS AN k, ; TEMSBCRECTORY. 194 ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)--Continued 3. Deck: C -15/32 Incline: Unlimited Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, Perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type Gi " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Weather Coat Emulsion" at 3 gal /sq. FLUID APPLIED COATING SYSTEM 1. Deck: NC Incline: Unlimited Surfacing. "Weathercote. VOC" or "Weathercote" - 2 gal /sq. SINGLE PLY MEMBRANE.,}OQFIN 'STEMS (MODIFIED BITUMEN) - Unless otherwise indicated phenolic insulation may be used in any of the following systems. Unless otherwise indicated any of the following Single Ply Membrane Systems may utilize multiple layers Of Ruberoid Membrane. "GAF Premium Aluminum Roof Coating" may be used on any of the following Classifications not exceeding 1/2 m. "GAF Weater Coat Emulsion" may be used on any of the following noncombustible Classifications not exceeding 1/2 in. Ruberoid® Modified Bitumen Adhesive, Monsey Corp. "MBA Gold" and Karnak "No. 81" adhesives may be used in any of the following noncombus- tible deck Classifications. Tropical Asphalt "No. 711 AF" adhesive may be used in any of the following Classifications: GAFGLAS #80 Premium Base Sheet may be used in any of the following systems. (Optional) Noncombustible deck classifications are applicable for use over combustihle (15/32 in. min plywood) decks when 1/2 in. (min) gypsum board or 1/4 in. (min) G-P Gypsum DensDeck® are used directly over the deck with all joints staggered 6 in. (min) from plywood joints. A vapor barrier may be optionally installed under all systems utilizing " EVERGUARD" insulation. "EVERGUARD" insulation is an acceptable alternate in any polyisocyanurate insulation of the following systems. GAF - GLAS Perlite may be used as an option over EVERGUARD insulation. GAF - GLAS Stratavent Perforated Base Sheet may be utilized as an additional ply in any of the following systems. The following membranes may be used interchangeably within their own group: A. Ruberoid Torch Granule ", "Ruberoid Torch Granule Plus ", "Ruberoid Torch Granule 1 ", Ruberoid Torch 180. B. w'Ruberoid Mop Smooth", "SBS HW Smooth", "Ruberoid 601 Cap Plus ", "Ruberoid 30" C. "Ruberoid MOp Granule ", "Ruberoid Mop Pliis Granule ", "SBS HW Granule ", "SBS HW Plus ". D. "Ruberoid Mop 170 FR (1 sq) ", "Ruberoid Mop 170 FR (1/2 sq)" E. "Ruberoid Mop FR 2 ", Ruberoid 30 FR ", "Ruberoid SBS Heat Weld 170 F. "Ruberoid 20", "SBS HW (Heat Weld) 25 ". G. "F1ame4Free 180 FR ", "Ruberoid Torch FR ", "Brai Supreme Plus APP Granule FR ", "GBSP- 250FR ", "Brai Supreme -APP Granule FR ".. Unless otherwise indicated the Modified Bitumen (Granule) membrane may be surfaced with Fireshr• )c MB" at 2.5 — 3.0 gal /sq and the incline of the resultant system would k creased to a 3/4 in. incline. But if the incline of the Classified system is greeter than a 3/4 in. incline, the incline of the roofing system would be maintained when surfaced with "Fireshield MB" at 2.5 — 3.0 gal /sq. Unless otherwise indicated "Ruberoid EnergyCap SUS 30FR" is an acceptable alternate for "Ruberoid 30 FR" or "Ruberoid Mop 170 FR" in any applicable Classification. Class A - Ballasted 1. Deck: NC Incline: 2 Insulation: One or two layers "Isotherm R ", any thickness, Ioose laid or mechanically fastened. Membrane: Any UL Classified membrane used in a ballasted system. Surfacing: River bottom stone, 3/4 to 1 -1/2 in. diam, 1000 lbs /sq. 2. Deck: C -15/32 Incline: 1/4 (NC -2) Insulation: Perlite, glass fiber or wood fiber, 3/4 to 1 -1/2 in. Membrane: "Ruberoid Torch Granule 1" (modified bitumen). Surfacing: Gravel at 400 lbs /sq, loose laid or concrete blocks, at 10 lbs /sq and spaced not more than 1/8 in.' 3. Deck: NC t Incline: 3 Insulation (Optional): Perlite, glass fiber or wood fiber, 3/4 to 1 -1/2 in. Base Sheet (Optional) Type 15, asphalt organic felt or °Type G2. Membrane: "Ruberoid Torch Granule 1" (modified bitumen). Surfa hi g 'Gra„vei.. Deck: C -15/32 Incline: 1/4 ROOF COVERINGMATERIALS (TENT) Roofing Systems (TGFU)— Continued Insulation (Optional): Perlite, glass fiber or wood fiber, any thickn "Ruberoid Torch Granule 1" (modified bitumen). Slip Sheet 0.004 in. polyethylene (not UL Classified). Surfacing. 3/4 in. thick concrete with one layer of No. 10 Summ- Quarry tile (or equivalent) grouted in place. 5. Deck: NC Incline: 2 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickn Membrane: "Ruberoid Torch Granule 1" (modified bitumen). Surfacing: 3/4 to 1 -1/2 in. diam river bottom stone at 1000 lb /sqf concrete pavers weighing not less than 10 lb /sq ft and spaced not m than 1/8 in. 6. Deck: NC Incline: 3 Insulation: a)Polystyrene, 2 in. max, b)Isocyanurate, any thickness, loosely. Membrane: "EverGuard SR" or "EverGuard FB ", 40-100 mil (TPA), loosely. Surfacing. River bottom stone (3/4 - 1 -1/2 in. diam) at 1000 lb/sq concrete roof pavers. 7. Deck: C -15/32 Incline: 1/2 Slip Sheet: One or more layers Atlas Roofing "FR50 ", mechani fastened. Membrane: "EverGuard TPO2 Plus ", 45 mil. Surfacing: River bottom stone, (3/4 to 1 -1/2 in. diem) at 1000 lbs /sqc, concrete roof pavers. 8. Deck: C -15/32 Incline: 1/2 Base Sheet: Two or more layers Type G2, "GAFGLAS Basesheet mechanically fastened. Membrane: "EverGuard TP02 Plus ", 45 mil. Surfacing: River bottom stone, (3/4 to 1 -1/2 in. diem) at 1000 lbs/ concrete roof pavers. Class A - Fully`tl.tllieree'd 1. Deck: NC "fiicline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, g fiber, isocyanurate, urethane, perlite /isocyanurate composite, perhl urethane composite, wood fiber /isocyanurate composite, phenolic, thickness. Base Sheet (Optional): One or more layers Type G1, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (Smooth or Graniil "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Gran or "Ruberoid Mop Plus Granule" (granule). Surfacing: Gravel, 400 lbs /sq, loose laid or applied in a flood coat of, roofing asphalt. 2. Deck: NC Incline: 1/2 Base Sheet (Optional): One or more layers Type Gl, G2 or G3. :.: 4 Membrane: One or more layers "Ruberoid Torch" (Smooth or Gran "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Gran`' , or "Ruberoid Mop Plus Granule ". Coating: Karnak No. 97, 1 -1/2 - 3 gal/sq. 3. Deck: NC Incline: 1/4 Insulation (Optional): One or more layers perlite, wood fiber, fiber, any thickness. Base Sheet (Optional): One or more layers Type Gl, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (Smooth or Gran "Ruberoid Torch Granule Plus ", "Ruberoid Mop Granule" or "Rubel' Mop Plus Granule". Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. 4. Deck: C-15/32 Incline: 1/2 Insulation: One or more layers perlite, glass fiber, isocyanurate, thane, perlite/isocyanuratecomposite, perlite /urethane composite, p, nolic, 1 -1/2 in. min thickness (offset from plywood joints 6 in.). Base Sheet One or more layers Type G2 or G3. Ply Sheet (Optional): One or more layers Type Gl. Membrane: One or more layers "Ruberoid ;'Porch" (Smooth or Granu "Ruberoid Torch Granule Plus ", . "RuberoiddMop" (Smooth or Gran ns ';Ruberoid Mop Plus Granule ". Sur aciftg3 TCarnak No. 97, 1.1/2 - 3 gal /sq. 5. Deck: NC Incline: 1/2 • One or more layers Type Gl, G2 or G3. re layers'' Ruberoid Torch" (Smooth or. Grand, Plus" Karnak . "Now/97 or "169" at 14 gal/ .c ion" at 3'gal /sq. lneirre: 1/2 • $,; Base Sheet (Optio Membrane; One or "Ruberoid ~Turch'Gr. Surfacing:.(Optional)V Grundy Ind. 110 F Em 6. Mac C- 15/32 LOOICPORRTHErUL,MARK ON PRODUCT 1 2007 °ROOFING MATERIALS AND`'SYSTEMS DIRECTORY ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued /Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocya- tnurate, urethane, perlite /isocyanurate composite, perlite /urethane com- O P i osite,1 -1/2 in. min. Base Sheet (Optional): One or more layers Type GI, G2 or G3. :Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". ;:.Surfacing. Gravel. �ale C -15/32 Incline: 1/2 V1nsglation (Optional): One or more layers perlite, wood fiber, glass isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite. ',Base Sheet: Two or more layers Type G2 or G3. r Ply Sheet (Optional): One or more layers Type C1. Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule), 'Ruberoid Torch Granule Plus ", "Ruberoid-Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfacing•. Karnak No. 97,1 -1/2 - 3 gal /sq or gravel. Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocya- nurate, urethane, perlite /isocyanurate composite, perlite /urethane com- posite, 1 -1 /2 in. min. 'Base Sheet (Optional): One or more layers Type Gl, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". tSurfacing: Grundy "AL MB Aluminum Roof Coating" at 1 -2 gal /sq. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 M. p: +min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ 5t urethane composite, phenolic, 1 -1/2 in. min. Base Sheet One or more layers Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. '::Ply Sheet One or more layers Type G1 "GAFGLAS Ply 4 ", hot mopped in place. + Membran e: "Ruberoid Mop 170 FR ". Surfacing (Optional): "GAF Fibered Aluminum Coating" at 1 -1/2 gal /sq or "GAF Weather Coat Emulsion" at 3 gal /sq. Deleted kiDeleted ?t.Deleted ;:Deleted Deleted ,, ' g peck 015/32 Incline: 1/2 Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane or perlite / isocyanurate composite. Base Sheet: One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. PI Sheet (Optional): One or more layers Type G1, hot mopped in irk; ` y P y YPe PP k, place. - Membrane: "Ruberoid.Mop 170 FR ". yfo.Deck: C -15/32 Incline: 1/2 Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane or perlite /isocyanurate.composite, offset 6 in. from joints, Base Sheet: One or more layers Type G -2 or G -3 base sheet, hot mopped y or mechanically fastened. Ply Sheet (Optional): One or more layers Type G-1, hot mopped in place. Membrane: One layer "Ruberoid Torch Smooth" or "Ruberoid Mop Smooth ". Membrane: One layer "Ruberoid Mop 170 FR ". Deck: NC Incline: 1 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyariurate, urethane or.perlite /isocyanurate composite. . Base Sheet One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type G1, hot mopped in place. Membrane: One layer "Ruberoid Mop 170 FR" 43. Deck NC Incline: 1 /2 Insulation (Optional): Perlite, fiber glass, wood- fiber, isocyanurate, f ; urethane or perlite /isocyanurate composite. Base Sheet (Optional): One or more layers Type G-2 or G -3 base sheet, hot mopped or mechanically fastened. ROOF COVERING MATERIALS (TEV7 195 Roofing Systems (TGFU)— Continued Ply Sheet (Optional): One or more layers Type G-1, hot mopped in place. Membrane: One layer "Ruberoid Torch Smooth" (smooth), "Ruberoid Mop Smooth". Membrane: One layer "Ruberoid Mop 170 FR" (granule). 19. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers perlite, glass .fiber, isocya- nurate, urethane or perlite /isocyanurate composite, any thickness. Base Sheet: One or more plies Type G1 or G2, hot mopped or adhered with Karnak Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 1 -1/2 gal /sq. Membrane: One layer "Ruberoid Mop 170 FR ", hot mopped or adhered with Karnak Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 1 -1/2 gal /sq. 20. Deleted 21. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Polyisocyanurate, wood fiber perlite, glass fiber any thickness, hot mopped or mechant' elly fastened. Base Sheet: One or more plies Type G2 "GAFGLAS #75" base sheets, hot mopped or mechanically fastened. Membrane: One or more plies "Ruberoid 30 FR" hot mopped in place. 22. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Polyisocyanurate, wood fiber, perlite, or glass fiber any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies Type G2 "GAFGLAS #75" hot mopped or mechanically fastened. Ply Sheet One or more plies "Ruberoid 20 ", hot mopped in place. Membrane: One or more plies "Ruberoid 30 FR ", hot mopped in place. 23. Deck: C -15/32 Incline: 1/2 -4:; Insulation (Optional): Fiber glass or perlite, mechanically fastened. Base Sheet One or more layers Type G2, hot mopped or mechanically fastened. Ply Sheet Two or more layers Type G1, hot mopped or mechanically fastened. Membrane: "Ruberoid 30" or "Ruberoid Modified Cap Sheet 601 ", hot mopped in place. Surfacing Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" or "Karnak No. 97 Asbestos Free Aluminum Roof Coating" at 1 to 2 gal /sq. 24. Deck: NC Incline: 1/4 Insulation (Optional): Polyisocyanurate, perlite, glass fiber or".twood fiber, 2 in. max. Base Sheet: Type 15 asphalt organic felt or Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid Torch Granule 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" or "Karnak No. 97 Asbestos Free Aluminum Roof Coating" at 1 to 2 gal /sq. 25. Deck: C -15/32 Incline: 1/4 Insulation: Two layers glass fiber (staggered joints), 1 in. each. Base Sheet Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Rub eaoi ' 1Oi'ch Granule 1 ". (modified bitumen). Surfacing. Karnak €hemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" at 1 to 2 gal /sq. 26. Deck: NC Incline: 1/4. . Membrane: " eroidl'ort Granule 1" (modified bitumen). Surfacing: Karn hero 'Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" at 1 to 2 gat /sq: 27. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, wood fiber or glass fiber, 1 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet Type G2 or "Flex Base 60" (modified bitumen), mechani- cally fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid Torch Granule 1 ", heat fused. Surfacing: Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5' gal /sq. 28. Deck: NC Incline: 1/2 >, Insulation (Optional): Perlite,,wood fiber, glass fiber or isocyanurate/ urethane board, 2 in. max, mechanically fastened. Base Sheet Type G2 '(modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid Torch Granule. 1" (modified bitumen), heat LOOK.FOR 'THE 'UL MARK ON PRODUCT