RF-12-1261Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 177284 Permit Number: RF -7 -12 -1261
Scheduled Inspection Date: August 14, 2012
Inspector: Bruhn, Norman
Owner: FONSECA, ANDRES
Job Address: 29 NE 105 Street
Miami Shores, FL 33138-
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Repair Roof
Phone Number
Parcel Number 1121360060110
Phone: (305)953 -3333
Building Department Comments
REPAIR LEAK AT REAR TILE ROOF ON MID SECTION
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
CREATED AS REINSPECTION FOR INSP- 175624.
August 13, 2012
For Inspections please call: (305)762 -4949
Page 22 of 28
be2g261-11
PERMIT APPLICATION
FBC 20
Miami Shores Village
Building Depart e
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
Permit Type: BUILDING
Owner's Name (Fee Simple Titleholder)
Owner's Address 29 N.E. 105 Street
Andres Fonseca
JUL La .-- 25 ii
BY:
Permit No. tap I
Master Permit No.
Phone# (305) 759 -5559
City Miami Shores
State
Florida
Zip 33138
Tenant/Lessee Name Phone #
Email
Job Address (where the work is being done) 29 N.E. 105 S t r ee t
City Miami Shores Village
FOLIO / PARCEL # 1 1 -21 3 6- 006 -011 0
Is Building Historically Designated YES
County Miami -Dade
zip 33138
NO X
Contractor's' Company Name Quaity Roofing Contractor,
Contractor's Address 13800 N.W. 1st Avenue
City Miami
State Florida
Rhone # (305),
Flood Zone
953 -3333
QnatifierName Carlos Arocho
State Certificate or Registration No. RC 0 0 5 8 6 2 7
Contact Phone (305) 953 -3333 E- qualit-yroofing88 @yahoo_com
Zip 331 68
Phone# ( 786) 367 -2029
Certificate of Competency No. 0 0 0 017 8 8 9
Architect/Engineer's Name (if applicable)
Phone #
Value of Work For this Permit $ 1,000.00
Type of Work: DAddition DAlteration
Describe Work: Repair leak at rear tile roof on mid section.
Square / Linear Footage Of Work: 1 / 2 sqf t .
ONew Zj Repair/Replace 0 Demolition
Submittal Fee $ Permit Fee $ ((71—) • C CCF $
Notary $
Scanning $ Radon $ DPBR $
Double Fee $ Violation date:
Training/Education Fee $
Structural Review. $
CO /CC $
Technology Fee $
Bond $
Total Fee Now Due $
See Reverse side -4
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
er or Agent
The foregoing instrument was acknowledged before me this
day of , 20 `,2,_by
who is personally known to me or who has produced
As identification and who did take an oath.
NOTARY PUBLIIC:
Sign:
Print:
NOlARY I LTiII 1C ST TF n,. nAmn
My Commission Exp' ": -s Marylou Hernandez
Commission #DD930046
, Expires: OCT. 10, 2013
BONDED THRU ATLANTIC BONDING CO., INC.
Signature
— (LYE" �itiP
Contractor
The foregoing instrument was acknowledged before me this
day of 0.." , 2012h, by l .t,( 1
who is personally known to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
My Commission Expires:
Mary ou Hernar:< L:
Commission #DD9:' )1;
Expires: OCT. 10 2('13
BONDED THRU ATLANTIC BONDING C ;, NC
vk4riknYak***+ YsYaY4r**** *4YvY*4 *Ar**4r*Y*3e**nY*sY4r9r4 *dedY**irvk*9roYok9Y*vk* iY**4r******dede9 ***k 4c4e**9c*vkatsY****4r**vY**9Y *** * #*gr* .****
APPROVED BY ���/� Z �3 /z Plans Examiner Zoning
Engineer Clerk checked
(Revised 07 /10 /07XRevised 06/10/2009)
ROOF ASSEMBUES AND ROOFTOP STRUCTURES .
c'Y
Master Permit No
Contractor's Name
Florida Building Code Edition
High Velocity Hurricane Zone Uniform Permit Ap
Section A (General Informat
Miami Shores Village
APPROVED BY DATE
ZONING DEPT
BLDG DEPT
7,/3 / /2.
2 InaECT TO COMPUANCE WITH ALL FEDERAL
li on Form.
TATE AND COUNTY RULES AND REGULATIONS
O
Process No
ualit Roofin• Contractor Inc.
Job Address 29 N.E. 105 Street
ROOF CATEGORY
Pe ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile
Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Prescriptive BUR -RAS 150
ROOF TYPE
Reroofing ❑ Recovering NI Repair ❑ Maintenance
ROOF SYSTEM
INFORMATION
Low Slope Roof Area (SF) N /A Steep Sloped Roof Area (SF) 1 / 2 s q . Total (SF) 1 / 2 s q .
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions o #elevated pressure zones and location of
Parapets.
IL \�
15.34 2010 FLORIDA BUILDING CODE — BUILDING
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
High- Velocity Hurricane Zone Uniform Permit Application Form.
Section D (Steep Sloped Roof System)
*Existing Tile Roof*
Roof System Manufacturer: Clay Forever
Notice of Acceptance Number: 11-0707 . 0 3
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations):
1: N/A p2: N /A p3; N/A
Roof Slope:
12
Steep Sloped Roof System Description
Deck Type:
wood 1 X 6
Type Underlayment:
Ridg &Vptilation?
Insulation:
301b.
N/A
Fire Barrier:
Mean Roof Height: 13
N/A
Fastener Type & Spacing:
Adhesive Type:
1 1/4" R/S nails
type 1V mopping asphalt
Type Cap Sheet:
901b. astm
Roof Covering:
Spanish S Clay Tile
Type & Size
Drip Edge:
3 X 3 26ga.
galv.
15,36 2010 FLORIDA BUILDING CODE — BUILDING
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govem the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1. Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system).
3. ef Common roofs: Common roofs are those which have no visible delineation between neighboring
units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or
owner should notify the occupants of adjacent units of roofing to be performed.
4. Kr- Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appearance.
5. Kr- Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. lF Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. fir Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of the
roof.
er /Agent's ignature Date
Revised on 7/9/2009 LD
Contractor Signature
Date
MIAMI.
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Clay Forever
6801 NW 77 Avenue, Suite 301
Miami, FL 33166
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.miamidade.aov/buildine/
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Altusa "S" Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub - Category: Roofmg Tiles
Material: Clay
Deck Tyne: Wood
1. SCOPE
This new roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de
C.U. in Pimienta, Honduras and distributed by Clay Forever LLC as described in Section 2 of
this Notice of Acceptance. For locations where the pressure requirements, as determined by
applicable Building Code does not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Altusa "S" Clay
Roof Tile
Trim Pieces
Test
Dimensions Specifications
Length: 18 -3/4"
Width: 10 -3/4"
varying thickness
Length: varies
Width: varies
varying thickness
2.1 SUBMITTED EVIDENCE:
Test Agency
American Test Lab of South
Florida
American Test Lab of South
Florida
IBA Consultants, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation Testing
Product
Description
High profile, one - piece, `S' shaped single roll
ASTM C 1167 clay tile with a nominal 2-Y2 inch headlap. For
adhesive set applications.
Accessory trim, clay roof pieces for use at
TAS 112 hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Test Identifier
RT0426.01 -11
RT0706.01 -11
2397 -116
94-083
94-084
25- 7200 -1
Project No. 307025
Test #MDC -78
MTS 520649
Test Name/Report
ASTM C 1167
Static Uplift Testing
TAS 101
ASTM C 1167
Static Uplift Testing
TAS 101 (Adhesive Set)
Static Uplift Testing
TAS 101 (Mortar Set)
Static Uplift Testing
TAS 102
(Quick -Drive Screws,
Battens)
Wind Driven Rain
TAS 100
TAS 102(A)
Date
05/07/11
07/11/11
06/28/07
April 1994
May 1994
Feb. 1995
Oct. 1994
May 2000
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 2 of 9
PRI Asphalt Technology, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
CLF- 003 -02-01
7161 -03; Appendix III
7161 -03
Appendix II
Letter Dated Aug. 1,
1994
P0631 -01
P0402
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
TAS 102
TAS 102
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Aerodynamic Multiplier
25 -7183
25 -7094
25 -7496
25 -7584
25- 7$04b -8
25- 7804 -4 & 5
25- 7848 -6
October 2001
Dec. 1991
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
March 1999
March 1995
February 1996
April 1996
December 1996
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofmg Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with the applicable Building Code.
3.7 May be installed on slopes 7:12 and greater.
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 3 of 9
4. INSTALLATION
4.1 Altusa "S" Clay Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (1 x w )
Tile Profile
Weight -W (Ibf)
Length -I (ft)
Width -w (ft)
Altusa "S" Clay Roof Tile
6.5
1.56
0.9
. Table 3: Restoring Moments due to Gravity - M. (ft -Ibf
Table 2: Aerodynamic Multipliers - a, (ft3)
3 ": 12"
or less
Tile
5 ": 12"
X (ft3)
7": 12" or
greater
X (ft3)
Profile
Direct
Deck
Batten Application
Direct Deck Application
Altusa "S" Clay Roof Tile
Direct
Deck
0.253
0.28
. Table 3: Restoring Moments due to Gravity - M. (ft -Ibf
Tile
Profile
3 ": 12"
or less
4 ": 12"
5 ": 12"
•6 ": 12"
7": 12" or
greater
Altusa "S"
Clay Roof
Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
4 A
5.35
4.40
5.27
4.31
5.16
4.20
5.03
4.08
4.89
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 4 of 9
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(Min 15/32"
plywood)
Direct Deck
(Min. 19/32"
plywood)
Battens
Altusa "8"
Clay Roof
Tile
2 -10d Ring Shank Nails
28.6
41.2
19.4
1 -10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2 -10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 .#8 Screw
28.7
28.7
18.1
2 .#8 Screws
58.2
58.2
26.8
1 -10d Smooth or Screw
Shank Nail (Field Clip)
23.1
23.1
19.0
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
29.3
29.3
24.0
2 -10d Smooth or Screw
Shank Nails (Field Clip)
27.6
27.6
38.6
2 -10d Smooth or Screw
Shank Nails (Eave Clip)
38.1
. 38.1
41.8
1 Screw with Altusa Clip (See c
ip details)
Altusa "S"
Clay Roof
Tile'
1 Screw with clip (at the
head of tile)
187.1
187.1
N/A
Altusa "S"
Clay Roof
Tile'
1 Screw with clip (at the
water course of tile)
35.2
35.2
N/A
1. Screw must be installed in the inside nail hole located nearest to the hump of the tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft -Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Altusa "S" Clay
Roof Tile
Adhesive
29.33
2 See manufactures component approval for installation requirements.
3 Flexible Products. Company TileBond Average weight per patty 10.7 grams.
Polyfoam Product, Inc. Average weight per patty 8 grams.
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 5 of 9
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf)
for Single Patty Adhesive,Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Altusa "S" Clay
Roof Tile
Polyfoam PolyProTM
66.54
Polyfoam PolyProTM
38.75
Polyfoam PolyProTM
52.055
4 Large paddy placement of 63grams of PolyPro TM.
5 Medium paddy placement of 24grams of PolyProw.
6 Large paddy placement of 54grams of PolyPro TM.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Altusa "S" Clay Roof Tile
Mortar Set'
24.50
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
detailed below, or following statement: "Miami -Dade County Product Control Approved ".
ALTUSA MADE IN HONDURAS
LABEL FOR ALTUSA "S" CLAY ROOF TILE.
(LOCATED ON THE UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 6 of 9
PROFILE DRAWINGS
ALTUSA `S' CLAY ROOF TILE
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 7 of 9
TILE BY ALTUSA
(TYP.)
CLIP DETAILS
2.112" OVERLAP
(COVERS PIN HOLE)
SCREW IN THE INSIDE HOLE
NEAREST TO THE HUMP OF THE TILE
CLIP WITH ONE (1) SCREW
ATTACHED TO DECK
CUP PLACEMENT DETAIL
DECK
B
CLIP
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 8 of 9
SCREW (HOLDS
CLIP ONTO DECK)
TILE BY ALTUSA
(TYP.)
CLIP DETAILS (CON'T)
21/2" OVERLAP
(COVERS PIN
HOLE)
END � I
SCREW IN THE INSIDE NAIL HOLE
NEAREST TO THE HUMP OF THE TILE
DECK
1 1/4" 13/4" 3/4"
CLIP PLACEMENT DETAIL
END OF THIS ACCEPTANCE
NOA No.: 11- 0707.03
Expiration Date: 08/26/14
Approval Date: 10/13/11
Page 9 of 9