Loading...
RF-12-758Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number. INSP- 172886 Permit Number: RF -4 -12 -758 Scheduled Inspection Date: May 31, 2012 Inspector: Bruhn, Norman Owner: GORMAN, SEAN CHELSEA Job Address: 372 NE 98 Street Miami Shores, FL 33138- Project: <NONE> Contractor: T &S ROOFING SYSTEMS INC. Permit Type: Roof Inspection Type: Roof Repair Work Classification: Repair Roof Phone Number Parcel Number 1132060135680 Phone: 305/265 -2654 Building Department Comments REPAIR TILE Passe.W1— /L Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments &Z- May 30, 2012 For Inspections please call: (305)762 -4949 Page 8 of 26 Miami Shores Village Building Department 90050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 S/3 /11/04tittaa-,e&,.. INSPECTION'S PHONE NUMBER: (305) 762.4949 B DING Permit No.R.C-:: PERMIT APPLICATION Master Permit No. FBC20`0 Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): „<t4/1 44044,14. l Phone#• Address: 377 iv( S? City: i �! W! + i VISAG 5 State: fc Zip: `7 Di DAll Tenant/Lessee Name: Phone#: Finail• JOB ADDRESS: -)17, 1" f elf 0 City: Miami Shores County: Miami Dade Zip: 3 )) 3a Folio/Parcel #: I I- 3766 - b r3- S b go Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: T 7 (/4I(19 c y vim Phone#: 9 d,-" Z6 f Address: (-! 6 I ti W Z 3 f I . City: taV W % p,,, State: Zip: ) Y Z Qualifier Name: Lord i ril i N ( Phone#: � �E ZAr _____ ,'/ State Certification or Registration #: (CC I77 fi P'7 Certificate of Competency #: Contact Phone#: gar- 79-7 --71sr Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 'Z 7,-.4 0 Square/Linear Footage of Work: Type of Work: DAddition OAlteration Description of Work: i.L,,R + < ' 3 \o{ roo? k'\e DNew E Repair/Replace DDemolition Submittal Fee $ CO Permit Fee $ /6 C% 0.1 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment: Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Si \‘',,,,.____, Signature Owner or Agent Contractor The for going instrument was acknowledged before me this The foregoing instrument was acknowledged before me t isV day of , 20 \t, by V eill 60/11140 .. . h , day of ; , 20 , by W c115 7 e who is personally known to me or who has produced \71 it.--- who As identification and who did take an oath. B . Notary Public State of Florida Daniel Perez My Commission EE123821 ofcuo' Expires 08/21/2015 to me or who has produced as identification and who did take an oath. NOT Sign: Print: My Co P Pser, Notary Public State of Florida Daniel Perez My Commission EE123821 'o? Expires 08/21/2015 ** * * * * * * * * ** * * *** * ***** ****+ ****** ** R4*******+R**** ***********F+k+R********+J«R+ * **al3+**+►************* *** ****+t ** APPROVED BY tp Plans Examiner Zoning Structural Review Clerk (Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09) 1461 NW 23 Street Miami, FL 33142 Dade: (305) 265 -2654 Broward: (954) 438 -9897 SYSTE11, Masters in modern -day roofing systems State cen• se No r` ? 5968 PROPOSAL AUBlyITTED TO ADDRESS Z !% . q7, sr 3ITY. STA E ND ZIP CODE 4RCHITECT PHONE '3G ; - (911-001 JOB NAME DAT JOB LOCATION DATE OF PLANS JOB PHONE WE HEREBY SUBMIT SPECIFICATIONS AND ESTIMATE FOR: (ntm f 6 y_ Ile.-- 1 tAK ,f 421 i ,a4 eon> c—,0-R vAl kiG c -SC v(-- DoE-. sit144 64, New TO—. N'U& gN-hv 1 oe otter 2 011ie & kick i(13 Iva t.A fL" 44 Is rev, -ee.h tt=to l Au„/I De6't) CI? AA Y - - - -- MONTHS WARRANTY- ON - LABOR- AND - MATERIALS ftS ^ .q t/ tf f C"OQ Ge 1'i4 j) _ 9i4{_ 'AYMENTS TO BE MADE AS FOLLOWS: 02-s7,), 9<-`7b-- LOCATION OF WORK TO BE PERFORMED: -10J •t-- deCue I matenal is guaranteed to be as specified. All worK to be completed in a workmanlike snner according to standard practices. Any alteration or deviation from above spedfica- msinvoMng- extra- casts -will- be-execnted- only -upon- written -orders; and-will- becmrne-an -- (Ire charge over and above the estimate. All agreements contingent upon strikes, :cidents or delays beyond our control. Owner to parry fire, tornado and other necessary surance. Our workers are fully covered by Workman's Compensation Insurance. ,CCEPTANCEOF PROPOSAL - The above prices, :eciflcatrons and conditions are satisfactory and are hereby accepted. You e authorized to do the wok as specified. Payment will be made as outlined rove.. DATE OF ACCEPTANCE 4 AUTHORIZED SIGNATURE THIS PROPOSAL MAY WITHDR BY US IF NOT CCEPTED WITHIN 6 DAYS SIGNATURE SIGNATURE • ,,.,,.r,..o ,a, na, niuf oa CTRPFT • e4IAMI Fl 35142 • PHONE:305.265.2.654 • PHONE:954.438.9897 • FAX:305.265.2685 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES - R CEOVED APR 3 0 2012 Awn Y*H. Florida Building Code Edition 20 gh- Velocity Hurricane Zone Uniform Penult Appllcatt Section A (( npral lnfnrmatin Master Permit No. l Z F C vT Contractor's Name 11 11 (II 001 Job Address t 41. eM. • Miami Shores Village APPROVED BY DATE ONING DEPT BLDG DEPT SUBJECT TO COMPLIANCE WITH ALL FEDERAL Process N ;TATr ANI) COUNTY RULES AND REGULATIONS ❑ Low Slope ❑ Asphaltic Shingles ❑ New Roof ❑ Mechanically Fastened Tile ,frMortarlAdhesive Set Tile ❑ Metal PaneUShingles 0 Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE I?I Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Sio Roof Area (SF) Steep Sloped Roof Area (SF) ,79„ iJ section R (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Repair ❑ Maintenance Total (SF). 1A Ti 1 FLORIDA BUILDING CODE — BUILDING 4-0 •V ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. SActinn rl (Steep Sloped Rnof System) Roof System Manufacturer: t Lfe1 � ce l,1 C �,e�r I VV Notice of Acceptance Number: cA _Ott .1\ Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations P1: ✓�.\ P2: FMS.) P3: lay? Maximum Design Pressure 31.3 -too 'TA i-1-1 kHe94e (From the Product Approval Specific System): cail,0gr4Se , Roof Slope: :12 Stepp Slnppd Rnnf System nescriptlnn Deck Type: slq cox `fsI woad Type Underlayment: Insulation: Fire Barrier: Fastener Type & Spacing: Adhesive Type: "IM rst Or eal Type Cap Sheet: Mean Roof Height: 5' Roof Covering: 14, Type & Size Drip Edge: FLORIDA BUILDING CODE — BUILDING t ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High- Velocity Hurricane Zone Uniform Permit Application Form. ,Spctinn F (TiJp Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from MF If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. `` Method 1 "Moment Based Tile Calcullationn RAS 127" 4•{ x %0g _ `• 1 6 ) -Mg: I/1!7 - =Mrii l Product Approval Mf �1 3at 1 W p Ip 1 4r• C!Q Product Approval Mf l�'J • Product Approval Mf !�J 1'• (P2: aa x Mg: V = Mt1 (P3: Ub1 xA _JL .70 n- Mg: K7.1\ =Mr3 Method 2 "Simplified Tile Calculations Per Table Below" Required - Moment of- Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height -, Roof Slope 2:12 3:12 16' 20' 25' 30' 34.4 32.2 36.6 382 39.7 42.2 34.4 36.0 37.4 39.8 4:12 5:12 6:12 30.4 7:12 32.2 33.8 35.1 37.3 28.4 264 24.4 30.1 31.6 32.8 34.9 28.0 29.4 30.5 32A 26.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS xL = xw: =_ -W: x cos 0 =Fri x w: = ) - W: x cos 8 = Fa -W: x cos8 =Fs (P2: • xL 27" Product Approval F Product Approval F' Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height 11 Job Site Roof 0 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M8 Calculated Minimum Attachment Resistance - Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE OA Monier Lifetile, LLC 200 Story Road Lake Wales, FL 33898 MIAMI DADE'COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules Miami-Dade e County Product Control Division and accepted The documentation submitted has been reviewed by by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product c the Control to Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product, Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been desid to g Cocomply with the Florida Building Code including the High Velocity Hurricane Zone of the DESCRIPTION: Atlantis Shake & Slate Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's or lo city, state d following statement: "Miami -Dade County Product Control Approved", ss otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code ne:r tively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been endorsement of change in the any materials, use, and/or manufacture of the .product process. al Misuse of terminate this NOA. Failure to comply product, for sales, advertising or any other purposes with any section of thisNOA shall be cause for termination and removal ofNOA. by ADVERTISEMENT: The NOA number preceded by the e. words s Miami-Dade County, NOA is displayed, and d, olio it d by the expiration date may be displayed in advertising literatur any portion be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #07- 1023.12 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAM14DADE COUNTY APPROVED NOA No.: 09- 0422.11 Expiration Date: 12 /16/12 ApprovarDate:-05/27/09 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub- Category: Material: Roofing. Flat Profile Roofing Tiles Concrete 1. SCOPE This renews a system using Monier Lifetile Atlantis Shake & Slate Concrete Roof Tile, as manufactured Monier Lifetile LLC in Pompano Beach, FL and described in Section 2 of this Notice of Acceptance. -- For locations where the pressure requirements, as - determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Monier Lifetile Atlantis Shake and Slate Tile Trim Pieces Dimensions 1= 16" w= 10" 1 1/4" thick I = varies w = varies varying thickness 2.1 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Test Specifications TAS 112 TAS 112 Test Identifier 7161 -03 Appendix III 94-060A 94-084 25- 7094 -2 The Center for-Applied 25 -7094-8 Engineering, Inc. The Center for Applied Engineering, Inc. a^.a .:.3. > �u I_�ui�r_Ari al •7.i alAI �+,t&'a�n,:ff, r,� a- APPROVED R•� 25- 7094 -5 Product Description Flat, interlocking, high pressure extruded concrete shake and slate roof tile equipped with two nail holes. For direct deck, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Mortar Set) (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static-Uplift Testing— PA 102. (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Date Dec. 1991 March, 1994 May 1994 Oct. 1994 -Oct. -1994 Oct. 1994 NOA No.: 09- 0422.11 Expiration Date: 12/16/12 X0527/07 Page 2 of 7 Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Test Identifier 25- 7183 -6 25- 7183 -5 25- 7214 -1 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 P0402 Project No. 307025 Test #MDC -77 224 -47099 520109 -1 520111 -4 520191 -1 Calculations Calculations Calculations Calculations Calculations Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineerins Nutting Engineerins Calculations Calculations Calculations TAS -112 TAS -112 Test Name/Report Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing PA-102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens), Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties. PA 112 Static Uplift Testing PA 101 Aerodynamic Multiplier Moment of Gravity 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 Date Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 199.1 Aug. 1994 July 1994 Sept. 1993 Oct., 1994 Sept. 1994 Dec. 1998 March 1999 October 2007 August 2007 February 1996 April 1996 December 1996 25- 7848 -6 25 -7183 March 1995 Aerodynamic Multipliers April 1999 Two Patty Adhesive Set System April 1999 13343.1 June 2007 13343.1 March 2009 NOA No.: 09- 0422.11 Expi ' Approval Date: 05/27/09 Page 3 of 7 3. LIMJTATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater with a minimum of two screws. . INSTALLATION 4.1 Monier Lifetile Atlantis Shake and Slate Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight W (Ibf) Length -I (ft) Width -w (ft) Monier Lifetile Atlantis Shake & Slate Tile 8.5 1.33 0.833 Tablet: Aerodynamic Multipliers- X ft3) Tile Profile X (ft3) X, (ft3) Batten Application Direct Deck Application Monier Lifetile Atlantis Shake & Slate Tile N/A 0.208 NOA No.: 09- 0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 4 of 7 Table 3: Restoring Moments due to Gravity - M (ft -Ibf) Tile Profile 2 ":12" 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" greater Battens or _Direct Deck Monier Lifetile Battens Direct • Deck Battens Direct Deck Battens Direct -Deck Battens Direct Battens Direct Atlantis Shake & Slate Tile Deck Deck N/A 6.17 N/A 6.11 N/A 6.01 N/A 5.89 N/A 5.75 N/A 5.59 NOA No.: 09- 0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Monier Lifetile Atlantis Shake & Slate Tile 2 -10d Ring Shank Nails 30.9 38.1 N/A 1 -10d Smooth or Screw Shank Nail 7.3 9.8 N/A 2 -10d Smooth or Screw Shank Nails 14.0 18.8 N/A 1 #8 Screw 30.8 30.8 N/A 2 #8 Screw 51.7 51.7 N/A 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 , N/A 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 N/A 2 -10d Smooth or Screw Shank Nails (Field .Clip) 35.5 35.5 N/A 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 N/A Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems - Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Adhesive' 31.32 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. Poiyfoam Product, Inc. Average weight per patty 8 prams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single -Patty Adhesive Set Systems - -- — Tile Profile Tile Application Minimum Attachment Mortar Setb .„'_. —,Re siits ance Monier Lifetile Atlantis Shake & Slate Tile PolyProTA° 118.93 PolyProT'" 40.4" 3 Large paddy placement of 45 grams of PolyProTm. 4 Medium paddy placement of 24 grams of PolyProT"'. NOA No.: 09- 0422.11 rationsDate 474 16142 Approval Date: 05/27/09 Page 5 of 7 Table 5B: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Mortar Setb 39,0 5 See specific mortar manufacturers Notice of Acceptance NOA No.: 09- 0422.11 rationsDate 474 16142 Approval Date: 05/27/09 Page 5 of 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". MONIER LIFETILE LLC, ATLANTIS SHAKE AND SLATE (POMPANO BEACH, FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 09- 0422.11 F rniratloDPSte92 %1+64 Approval Date: 05/27/09 Page 6 of 7 PROFILE DRAWINGS 1" -1112" „.•■■•4 .. „,„ ... . ••••• VIAIERLOCIC ,... 1611'5" ........ •-,„.. *,,,, , ... ..... ._ ... --. ...... . , -,... ....„. .:, , , - , -,.:-...,... -,... , '',...•-, ,..., ~-,...- ----„, ---....z,-,.. ---, , ,.. -.....,... A ...,_s,..,... ,_....... „.„.. ,69.., .,-• ,,. '-,, mug ----.:::,:-.::-.. '.--:::-... --e' —1 MONIER LIFETILE ATLANTIS SHAKE & SLATE CONCRETE ROOF TILE END OF THIS ACCEPTANCE APPROVED NOA No.: 09-0422.11 Expiration Date: 12/16/12 /09 Page 7 of 7 NIAM1 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA # 11- 0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 pprova a : Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Sub - Category: Material: Roofing Underlayment SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR-Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Surface Printing) Manufacturing Location #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65' x 3'3-3/8" Or 65' x3' 60 mils thick Roll: 32'10" x 3'33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick _._ Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofmg membrane, glass fiber reinforced with polyolefmic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and - Afine- granular /sand top surface - self - adhering, ASTM D 1970 APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. TAS 103 and . ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofmg membrane, glass -fiber /polyester reinforced, with a granular surface designed for use as .a tile roof underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. TAS 103 and A rubberized asphalt self - adhering, glass - ASTM D 1970 fiber /polyester reinforced waterproofing membrane._ Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 pprova a e: Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 - 33370.04.11 P36900.09.11 P37300.10.11 PRI01111 PUSA- 005 -02 -01 PUSA- 018 -02 -01 PUSA - 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report. TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103 /ASTM D4798 & G155 TAS 110 /ASTM D4798 & D1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 1229.01 Expiration Date: 09/13/16 ppTh a a e: Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum. of 3 -i4 and end laps - shall -be-a- minimum -of 6.!'- -Roll the- membrane -into place -after- removing- the - release strip. - Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations Polystick IR Xe 1 Polystick TU, TU Plus, TU P, Tile Pro (days) Prohibited without battens MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N /A. N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, and Tile Pro may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof file applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof file underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR Xe 1 Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 0 0. 0 6 Roofing Tiles (6 Max Per Stack) 12 11. Refer to prepared roofmg system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 1229.01 "Expiration-Date: 09/13/16 Approval Date: 04/05/12 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet /Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply xoPolystickMTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"112 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofmg tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly_ prepared, before_anypplication of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 1229.01 Expiration Date: "09/13/1-6 Approval Date: 04/05/12 -Page 7 oft 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 8 of 8 MIAM2 COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11 805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.mla midade.gov /building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AFI160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigers. MIAMIOADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves Polypro® A}1160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system . for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Polypro1 AH160 Dimensions Test Product DeserinHon Specifications N/A TAS 101 Two component polyurethane foam adhesive Foampro ? RTF1000 N/A Dispensing Equipment ProPacko 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Pronertv Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.61bsift.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158 °F.,100% Humidity, 2 weeks • 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04114/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 041Q8194 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1} ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109-2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro®AH160_ shall- solely- be -used with - flat, low, & high - tile- profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120, 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof the adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. _W 2 MIAMI•DADE COUNTY APPROVED F'- MS NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance' with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro AH160 Operating Instruction and Maintenance Booklet. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro @ dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.017510 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to:3 minutes after Polypro® A11160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 - N/A High Profile (2 Piece Barrel) -- — #1 _ — 17 /side on cap and 34 /pan - -- N/A - Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All PolyproiI AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Mail throng!) plastic cement Paddy (Beneath TIM) Underlayment 1 10 fn`. Witham Esve Closure — Fascia Ease couneonly: Keep adhesive appmx, 4 In. uP ham weepholes 1) pence enough adhesive toachieve 17to23 square Inches In contact wfhthe pan the 2) Tc ensn ups* d. Placa 112In. a ilea ed � Then Install the Se. Option 2x4& tor steep pitch applications Meg Waugh plastic cement MJAMIDADE COUNTY APPROVED Be too portion oftheeava course cover the. Abut tosmwrd mace oi pantiles, Enacts we andef pan and cover tuestoe gush at ease line. Eased** Weephde Fes* (mortar shown) Sheathing Optional Potabap Mortar on edges longitudeal NQA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 5 of 7 v ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Fascia weaphale Eave clasare Drip edge MIAMFDADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04 /14/11 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy (between tile) Paddy (under tile) • Single paddy 3 h. under file x3 3 l in. Single paddy on under- _lament Single paddy on top of file course In. X7 In. medium size paddy save Fascia course only Nall through plastic cement Underlayment Single paddy under tile Single paddy between tile 2 in. x 7 In. medium size paddy save course only r In.x Single 41n. paddy on under. Iayment Single paddy on top of tile t% e Course Fascia Weephoie Paw :closure Drip edge END OF THIS ACCEPTANCE MANMADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. ( Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. I , Ventilation: Most roof structures should have some ability to vent natural airflow through the • in en r of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the not Owner /A Revised on 7/9/2009 LD ate Contractor Sig atu -2� —12 ate