RF-11-14821
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
RC- 11- 10 L�
Inspection Number: INSP- 172521 Permit Number: RF -8 -11 -1482
Scheduled Inspection Date: May 25, 2012
Inspector: Bruhn, Norman
Owner: MEHTA, SAILESH
Job Address: 10480 NE 5 Avenue
Miami Shores, FL 33138-
Project: <NONE>
Contractor: HOME OWNER
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Flat
Phone Number (305)491 -5729
Parcel Number 1122310150010
Building Department Comments
NEW TILE ROOF OVER UTILITY AREA
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
CREATED AS REINSPECTION FOR INSP- 169898. CREATED AS
REINSPECTION FOR INSP- 163255. Roof flashing and tile are not per code.
NB
Same comments, cancelled in field with owner. NB
May 24, 2012
For Inspections please call: (305)762 -4949
Page 5 of 10
t
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FLitiRcil
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 163252
Permit Number: RF -8 -11 -1482
Scheduled Inspection Date: January 10, 2012
Inspector: Bruhn, Norman
Owner: MEHTA, SAILESH
Job Address: 10480 NE 5 Avenue
Miami Shores, FL 33138-
Project: <NONE>
Contractor: HOME OWNER
Permit Type: Roof
Inspection Type: Tin Cap
Work Classification: Flat
Phone Number (305)491 -5729
Parcel Number 1122310150010
Building Department Comments
NEW TILE ROOF OVER UTILITY AREA
Infractio
Passed Comments
TIN CAP SPACEING
False
Inspector Comments
Passe
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
January 09, 2012
For Inspections please call: (305)762-4949
Page 3 of 25
MSV Permit # RF -8 -11 -1482 DATE: /2/2e)
of
INSPECTION AFFIDAVIT
Date: // c /2o I I Time (� , ®co
Inspection
Engineer:
Property Owner:
Job Site
Daniel Lopez P.E.
License #: FL. P.E. 69761
Sailesh Mehta
10480 NE 5 Ave.
Miami Shores, FI. 33138
I, Daniel Lopez, licensed as an Engineer, located at 19341
Sterling Drive Miami, FI. 33157, Phone 305 - 970 -5201, at the
request of the owner did personally conduct a visual Roof
inspection for the following items at the above reference job
site address.
1. Roof Sheathing
2. Nail
Based upon that inspection examination I have determined
the installation was done according to the Florida Building
Code & Hurricane Mitigation Retrofit Manual (Based on
553.844 F.S.)
Si jnture
Daniel Lopez
MSV Permit # RF -8 -11 -1482 DATE: / 2/2 4o/
Inspection
Engineer:
INSPECTION AFFIDAVIT
Date Vi 0/20 / 1
Daniel Lopez P.E.
License #: FL. P.E. 69761
Property Owner:
Job Site
Sailesh Mehta
10480 NE 5 Ave.
Miami Shores, FI. 33138
I, Daniel Lopez, licensed as an Engineer, located at 19341
Sterling Drive Miami, FI. 33157, Phone 305- 970 -5201 at the
request of the owner did personally conduct a visual Roof
inspection for the following items at the above reference job
site address.
1. Cap Sheet
2. Tin Cap
3. Mop in Progress
Based upon that inspection examination I have determined
the installation was done according to the Florida Building
Code Hurricane Mitigation Retrofit Manual (Based on
553.844 F.S)
Danig' Lopez
hi i r• - mr,,�,,,a
B I DING
PERMIT APPLICATION
FBC zoffl
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PRONE NUMBER: (305) 762.4949
Permit Type: BUILDING
ROOFING
Permit No.
Master Permit No.PC-211-
r 101 4
RECRE
AUG 1 2 2011
BY: ...
1F11--121-S7-
Owner's Name (Fee Simple Titleholder) .A Lt✓S4i -r7 iLt Phone #
Owner's Address ® c i4 4
City it'( A-.M. } State Z Zip 3. 1.3
Tenant/Lessee Name
Email
Job Address (where the work is being done)
City
Miami Shores Villa • e
Phone #
FOLIO / PARCEL #
County Miami-Dade Zip 33 ! g
Is Building Historically Designated YES
Contractor's Company Name
Contractor's Address
City
Qualifier Name
NO,
State
Phone #
Flood Zone
zip 3313
Phone #
State Certificate or Registration No. Certificate of Competency No.
Contact Phone
Architect/Engineer's Name (if applicable)
Value of Work For this Permit $
E -mail
Phone #
aco
Square / Linear Footage Of Work: r 3 7 VI
Type of Work: (%ddition ❑Alteration ❑New ❑ Repair/Replace ❑ Demolition
Describe Work:
(1-.00t% t
LITt
**** ** * *r * * * * * *** * * * * *** * * ** ** * * * * * ** Fees * * * * ** * * ** *, ** *x *, * * * *x * * ** * ** * * * *x * *x ** **
Submittal Fee $ Permit Fee $ /t) d °k)
CCF $ CO /CC $
Notary $ Training/Education Fee $
Scanning $ Radon $ DPBR $
Double Fee $ /040 c4) Violation date:
Structural Review. • d` Total Fee Now Due $ 20&10(")
See Reverse side - *
Technology Fee $
Bond $
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a hopy of the notice of commencement and construction lien lam' brochure will be delivered to the person
whose properly is subject to tiittachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs- seven• (7) days after the building permit is issued in -the absence of such posted notice, the
inspection will not be approved and a reinsppection fee will be charged.
Signature
The for �in,
day of
who is perso
Signature J�
Owner or Agent _ — Contractor,-'
ent was ac wj dge before a 's d The foregoing instrument was acknowledged before me this
�� 1 g g g
,20 fl, by �� 1 � t) , day of ,20,by
lly known to me or who has produced who is personally known to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOT ' LIC: � NOTARY PUBLIC:
Sign:
Print:
My Commission Expires:
'ON
c Ca' :3
01+1=
� 4
Plans Examiner Zoning
Sign:
Print:
My Commission Expires:
APPROVED BY
Engineer Clerk checked
(Revised 07 /10 /07)(Revised 06/10/2009)
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Sketch
Include
parapets.
lomma
SEP 31'it'f1r
» ,
Miami Shores Village
APPROVED
BV
DATE
ZONING DEPT
Building Code Edition 2800'77n �/
rricane Zone Uniform Permit AppIIc Jfl 3 nR EPT /�/
Master Perm No. > .............� o� "--I TT
Contractor's Name Le-g1-0 eiVrtrat
Job Address tke4T3 E e-
S BJECT TO COMPLIANCE WITH ALL FEDERAL
STATE AND COUNTY RULES AND REGULATIONS
Process No.
❑ Low Slope
❑ Asphaltic
Shingles
❑ Mechanically Fastened Tile
❑ Metal Panel /Shingles
Mortar /Adhesive Set Tile
❑ Wood Shingles/Shakes
❑ Prescriptive BUR -RAS 150
ROOF TYPE
New Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ Maintenance
ROOF SYSTEM
INFORMATION
Steep Sloped Roof Area (SF)
Sectlol{Roof plan)
rate ° le Is and sections, roof drains, scuppers, overflow scuppers and overflow drains.
levels, clearly identify dimensions of elevated pressure zones and location of
Total (S
�e
ir
FLORIDA BUILDING CODE — BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High - Velocity Hurricane Zone Uniform Permit Application Form.
Spctior JStaftp Sloped Roof System)
Roof System Manufacturer: klr u s 4, 60,911
Notice of Acceptance Number: ®--) DI ► c? 0
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
CalculationsIS1: )•
`) 4 P2: /6 .: ‘ P3: t cry •(
Maximum Design Pressure
(From the Product Approval Specific System): 66 e „
Roof Slope:
: 12
,Stepp SInperi Rnof System nescriptinn
\ Deck Type:
Type Underlayment:
Insulation:
Wci
Ridge Ventilation?
PO
Fire Barrier:
Mean Roof Height: 1 V tt
Fastener Type & Spacing:
Adhesive Type:
Type Cap Sheet:
Roof Covering:
Type & Size Drip
Edge:
FLORIDA BUILDING CODE — BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High- Velocity Hurrican no Uniform Permit Application Form.
Sectio Tile Calculations}
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Me If the M (values are greater than or
equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 "Moment Tile Calculations Per RAS 127"
(P1: - o f• sa x),, a�i ,, ) - Mg: ° � = Mri °,c > Product Approval Mr
(P2: PJ - x) �► 1 ) - Mg: P ` = Ma , Product Approval Mf 46 `)
(P31) 6.A. Zyi ) - Mg: = Mr3 1 C ` V/ Product Approval Mf ° 3
Method 2 "Simplified The Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below , Product Approval Mr
Mean Roof Height -'
Roof Slope 4,
15'
M, reguired Moment Resistance*
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
6:12
28A
30.1
31.8
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals.
For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F'values are greater than or equal to the Fr values,
for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Moment Based Tile Calculations Per RAS 127"
(Pl: x L = x w: = _J - W: x cos 0 = Fri Product Approval F'
(P2: x L = x w: = _) - W: x cos 0 = Fe Product Approval F'
(P3: x L = x w: = _) - W: x cos 0 = F 3 Product Approval
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
PI or P2 or P3
RAS 127 Table 1 or by an engineering analvsis prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
A
Product Approval
Restoring Moment due to
Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
M8
Calculated
Minimum Attarh,nent
Resistance
r
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L= length
W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
FLORIDA BUILDING CODE - BUILDING
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govem the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1.
Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the a. reement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
w.
renail' in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system).
3. Common roofs: Common roofs are those which have no visible delineation between neighboring
units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or
o r should notify the occupants of adjacent units of roofing to be performed.
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
apeearance.
5. ' " Ponding water: The current roof system and /or deck of the building may not drain well and may
cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
on ' al roofing system is removed. Pounding conditions should be corrected.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
Ventilation: Most roof structures should have some ability to vent natural airflow through the
of the structure assembly (the building itself). The existing amount of attic ventilation shall not be
re. -d. It may be beneficial to consider additional venting which can result in extending the service life of the
roof.
Contractor Signature Date
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION
RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT
TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, Fl 33138
Re: Owner's Name: A3k`e1.-
Property Address: t £�
Date: 121 11
Roofing Permit Number:
Dear Building Official:
1 SA / L51 IrtC---erePt— certify that I have improved the roof to wall connections of the referenced
property as',-quired by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential
Structures as adopte. Florida Building Commission by Rule 9B -3.047 F.A.C.
if "Or-
Signatu - Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he /she is the owner for the above property mentioned.
Swom to and subscribed before me this day of 20
Notary Public, Sate of Florida at Large
(SEAL)
FINAL COMPLIANCE
Revised on 5/21/2009
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, Fl 33138
Re: Owner's Name: `-�� "➢ �' $"`��
Property Address: k 0 at 0-se-, S
Roofing Permit Number:
Dear Building Official:
1 t m certify that I am not required to retrofit the roof to wall connections of my
buildin because:
he just valuation for the structure for purpose of ad valorem taxation is less than 300 000.00. Please attach proof just p rp $ p of ad
valorefB taxation.
he buildi was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition o - outh Florida Building Code (1994 SFBC)
Date: cl (2-1( 1
c)ltra ��� 't\.£11,- 1/aC
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned.
Swom to and subscribed before me this day of
Notary Public, Sate of Florida at Large
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994
SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
MIAMI DBE
C U.NTY
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.miamidade.gov/building/
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Modified Bitumen Roof System Over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 08- 0827.18 and consists of pages 1 through 34.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 1 of 34
ROOFING ASSEMBLY APPROVAL
Category:
Sub - Category:
Materials
Deck Tvpe:
Maximum Design
TRADE NAMES
Product
Polyflex
Polyflex G
Polyflex G FR
Polybond
Polybond G
Elastoflex S6
Elastoflex S6 G
Elastoflex S6 G
FR
Roofing
Modified Bitumen
SBS /APP/TPO
Wood
Pressure -112.5 psf
OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
BLE 1
Test
SpecificaTAtion
ASTM D 6222
Dimensions
32' 10" x 3' 3 -3/8"
32' 10" x 3' 3 -3/8" ASTM D 6222
32' 10" x 3' 3 -3/8" ASTM D 6222
32' 10" x 3' 3 -3/8" ASTM D 6222
32' 10" x 3' 3 -3/8" ASTM D 6222
Type I
32' 10" x 3' 3 -3/8" ASTM D 6164
32' 10" x 3' 3 -3/8"
32' 10" x 3' 3 -3/8"
MIAMI ADE COUNTY
APPROVED
ASTM D 6164
ASTM D 6164
Product
Description
Torch applied, polyester reinforced, APP
modified bitumen membrane with a bum off
polyethylene back face and a smooth or sanded
top surface.
Torch applied, polyester reinforced, APP
modified bitumen membrane with a burn off
polyethylene back face and a granule top
surface.
Torch applied, polyester reinforced, APP
modified bitumen membrane with a bum off
polyethylene back face and a granule top
surface and fire retardant chemistry.
Torch applied, polyester reinforced, APP
modified bitumen membrane with a bum off
polyethylene back face and a smooth or sanded
top surface.
Torch applied, polyester reinforced, APP
modified bitumen membrane with a bum off
polyethylene back face and a granule top
surface.
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a polyethylene or sanded
top surface.
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a granule top surface.
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a granule top surface and
fire retardant chemistry.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 2 of 34
Product
Elastoshield TSG
Elastoshield TSG
FR
Elastoflex V
Polyfresko Mop
Dimensions
32' 10" x 3' 3 -3/8"
32' 10" x 3' 3 -3/8"
32' 10" x 3' 3 -3/8"
32' 10" x 3' 3 -3/8"
Polyfresko Mop 32' 10"
FR
Polyfresko Torch
Polyfresko Torch
FR
Elastobase
Elastobase P
Cold Process
Adhesive
PG100 Asphalt
Primer
PG350 Mod Bit
Adhesive
PG400 Plastic
Roof Cement
3' 3 -3/8"
32' 10" x 3' 3 -3/8"
32' 10" x 3' 3 -3/8"
65' 2" x 3' 3 -3/8"
65' 2" x 3' 3 -3/8"
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal,
tube or 17 oz.
spray can
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
Test
Specification
ASTM D 6164
ASTM D 6164
ASTM D 6163
ASTM D 6164
ASTM D 6164
ASTM D 6222
ASTM D 6222
ASTM D 6163
Type I
ASTM D 6164
ASTM D3019
Type III
ASTM D41
ASTM D3019
Type III
ASTM D4586
ASTM D3409
Product
Description
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a granule top surface.
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a granule top surface and
fire retardant chemistry.
Torch, hot asphalt or cold adhesive applied,
fiberglass reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a sanded top surface.
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a granule top surface.
Torch, hot asphalt or cold adhesive applied,
polyester reinforced, SBS modified bitumen
membrane with a burn off polyethylene or
sanded back face and a granule top surface and
fire retardant chemistry.
Torch applied, polyester reinforced, APP
modified bitumen membrane with a burn off
polyethylene back face and a granule top
surface.
Torch applied, polyester reinforced, APP
modified bitumen membrane with a burn off
polyethylene back face and a granule top
surface and fire retardant chemistry.
SBS modified asphalt coated fiberglass
reinforced base sheet.
SBS modified asphalt coated polyester
reinforced base sheet.
A fibered cold process adhesive for use with
roll or BUR roofing.
A penetrating solution of solvent and a blend of
selected asphalts used to promote adhesion.
A fibered rubberized adhesive designed for use
with modified bitumen membranes.
A thick, fibered, rubberized flashing cement for
use in dry or damp conditions.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 3 of 34
Product
PG425 Wet/Dry
Roof Cement
PG450 Flashing
Cement
PG500 MB
Flashing Cement
Polyplus 35
Premium Mod Bit
Adhesive
Polyplus 45
Premium Flashing
Cement
Polyplus 50
Premium MB
Flashing Cement
Polyplus 55
Premium Modified
Flashing Cement
Dimensions
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1,3,5,50,55 gal.
Test
Specification
ASTM D4586
ASTM D3409
ASTM D4586
ASTM D4586
ASTM D3019
Type III
ASTM D4586
Product
Description
A thick, fibered, rubberized flashing cement for
use in dry or damp conditions.
A thick, fibered, rubberized flashing cement.
A thick, fibered, rubberized flashing cement for
use with modified bitumen membranes.
A fibered rubberized adhesive designed for use
with modified bitumen membranes.
A thick, fibered, rubberized flashing cement.
ASTM D4586 A thick, fibered, rubberized flashing cement for
use with modified bitumen membranes.
ASTM D4586 A mastic compound for use as a roof flashing
or tube adhesive.
APPROVED INSULATIONS:
Product Name
POLYTHERM
POLYTHERM Composite
ACFoam II, ACFoam III
High Density Wood Fiberboard
Perlite Insulation
Type X Gypsum
Dens -Deck or Dens Deck Prime
Fesco Board
H- Shield
ENRGY -3
Multi- Max -3, Multi -Max FA -3
Securock
TABLE 2
Product Description
Polyisocyanurate foam insulation
Polylso /perlite composite insulation.
Polyisocyanurate foam insulation
Wood fiber insulation board
Perlite insulation board
Fire resistant rated gypsum.
Gypsum insulation board
Rigid perlite roof insulation board.
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Fiber reinforced coverboard
Manufacturer
(With Current NOA)
Polyglass USA, Inc.
Polyglass USA, Inc.
Atlas Energy Products
Generic
Generic
Generic
Georgia - Pacific
Johns Manville
Hunter Panels, LLC
Johns Manville Corp.
RMax, Inc.
USG
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 4 of 34
APPROVED FASTENERS:
Fastener
Number
1.
2.
3.
4.
5.
6.
7.
8.
Product
Name
Dekfast Fasteners
#12, #14 & #15
Dekfast Hex Plate
Dekfast Lock
Plate
#12 & #14 Roofgrip
Metal Plate
Plastic Plate
Tru -Fast HD
Tru -Fast Plates
9. Tru -Fast Plates
APPROVED SURFACING:
Number
Product
Name
1. PG200 Non - Fibered
Roof Coating
2. PG300 Fibered Roof
Coating
3. PG600 Non - Fibered
Aluminum Roof
Coating
4. PG650 Fibered
Aluminum Roof
Coating
TABLE 3
Product
Description
Insulation fastener for wood,
steel and concrete decks
Galvalume hex stress plate.
Polypropylene locking plate.
Insulation and membrane
fastener
Galvalume AZ50 stress plate
Polyethylene stress plate
Insulation fastener for steel and
wood decks
Galvalume AZ55 steel plate
Polyethylene plastic plate
TABLE 4
Product
Description
A non fibered asphaltic
coating used to add life and
rejuvenate existing BUR
roofing substrates.
An asphalt cutback fibered 11/2-2 gal/sq
roof coating. May be
applied by brush or spray
equipment to rejuvenate
aged BUR
Non - fibered aluminum roof
coating.
Dimensions
2'/ s " X
3 '/4"
3" x 3 ' /4"
Various
Manufacturer,
(With Current NOA)
SFS Intec
SFS Intec
SFS Intec
OMG
3" square OMG
3.2" round OMG
The Tru -Fast Corp.
3" round The Tru -Fast Corp.
3" round The Tru -Fast Corp.
Application
Rate
1' /z -2 gal/sq
Fibered aluminum roof
coating.
1/2-1 gal/sq
11/2-2 gal/sq
Specification
TAS 140
ASTM D4479
ASTM D2824
Type I
ASTM D2824
Type III
Manufacturer
Polyglass
USA, Inc
Polyglass
USA, Inc.
Polyglass
USA, Inc.
Polyglass
USA, Inc.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 5 of 34
APPROVED SURFACING:
Number
Product
Name
5. PG700 White
Reflective Roof
Coating
6. PG800 Non - Fibered
Asphalt Emulsion
Roof Coating
7. PG850 Fibered
Asphalt Emulsion
Roof Coating
8. Polyplus 65
Premium Fibered
Aluminum Roof
Coating
9. Polyplus 60
Premium Non -
Fibered Aluminum
Roof Coating
10. Polybrite 70 White
Elastomeric Roof
Coating
11. Mule -Hide 111 Non -
Fibrated Roof
Coating
12. Mule -Hide 102
Fibrated Roof
Coating
13. Mule -Hide 416
Standard Non -
Fibrated Aluminum
Roof Coating
TABLE 4
Product
Description,
A premium white
elastomeric acrylic based
roof coating (water - based).
A polyester fabric may be
used for reinforcement with
this coating.
An asphalt based, non-
fibered clay emulsion
An asphalt base, fibered
clay emulsion
Fibered aluminum roof
coating.
Non-fibered aluminum roof
coating.
A premium white
elastomeric acrylic based
roof coating (water- based).
A polyester fabric may be
used for reinforcement with
this coating.
A non-fibered asphaltic
coating used to add life and
rejuvenate existing BUR
roofing substrates.
An asphalt cutback fibered
roof coating. May be
applied by brush or spray
equipment to rejuvenate
aged BUR
Non-fibered aluminum roof
coating.
Application
Rate
Specification Manufacturer
1-1Y2 gal/sq ASTM D6083 Polyglass
USA, Inc.
3 gal/sq in ASTM D1227 Polyglass
two coats USA, Inc.
3 gal/sq in ASTM D1227 Polyglass
two coats USA, Inc.
11/2-2 gal/sq ASTM D2824 Polyglass
Type III USA, Inc.
%2 -1 gal/sq ASTM D2824 Polyglass
Type I USA, Inc.
1 -1Y2 gal/sq ASTM D6083 Polyglass
USA, Inc.
11/2-2 gal/sq TAS 140 Mule -Hide
Products Co.,
Inc.
1Y2-2 gal/sq ASTM D4479 Mule -Hide
Products Co.,
Inc.
Y2 -1 gal/sq ASTM D2824 Mule -Hide
Type I Products Co.,
Inc.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 6 of 34
APPROVED SURFACING:
Number
Product
Name
14. Mule -Hide 406
Standard Fibrated
Aluminum Roof
Coating
15. Mule -Hide 401
Premium Fibrated
Aluminum Roof
Coating
16. Mule -Hide 410
Premium Non -
Fibrated Aluminum
Roof Coating
17. Mule -Hide 311
Emulsion Non -
Fibrated
18. Mule -Hide 301
Emulsion Fibrated
19. Gravel
20. Slag
TABLE 4
Product
Description,
Fibrated aluminum roof
coating.
Fibrated aluminum roof
coating.
Non - fibered aluminum roof
coating.
An asphalt base, non-
fibered clay emulsion
An asphalt base, fibered
clay emulsion
To be installed in a flood
coat of approved asphalt at
60 lbs /sq
To be installed in a flood
coat of approved asphalt at
60 lbs /sq
Application
Rate Specification Manufacturer
11/2-2 gal/sq ASTM D2824
Type III
11/2-2 gal/sq ASTM D2824
Type III
1/2-1 gal/sq
3 gal/sq in
two coats
3 gal/sq in
two coats
400 lbs /sq
300 lbs /sq
ASTM D2824
Type I
ASTM D1227
ASTM D1227
N/A
N/A
Mule -Hide
Products Co.,
Inc.
Mule -Hide
Products Co.,
Inc.
Mule -Hide
Products Co.,
Inc.
Mule -Hide
Products Co.,
Inc.
Mule -Hide
Products Co.,
Inc.
Generic
Generic
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 7 of 34
EVIDENCE SUBMITTED:
Test Agency
Factory Mutual Research
Corporation
Underwriters Laboratory
Trintiy 1 ERD
PRI Asphalt Technologies
Test Name/Report
Report No. Date
4470 J.I. 2W7A7.AM 08.04.94
4470 J.I. 3001334 02.15.00
4470 J.I.3000857 01.12.00
4470 J.I. 3004091 01.12.00
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 117(B) -ASTM D6862
ASTM D 6164 / D 6222
ASTM D6222
ASTM D6163
00NK20869 06.08.00
#11751.05.03 05.30.03
11757.12.00 -1 12.01.00
11757.04.01 -1 04.27.01
#11758.08.03 08.11.03
#P1738.02.07 02.05.07
C8500SC.11.07 11.30.07
P10490.08.08 08.14.08
PUSA- 062 -02 -01 12.04.07
PUSA- 064 -02 -02 02.27.08
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 8 of 34
APPROVED ASSEMBLIES
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 screws at 6" o.c.
System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System limitations apply.
One or more layers of the following:
Anchor Sheet: One ply of Elastobase Poly /Sand, Sand/Sand fastened to the deck as described
below:
Fastening: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates spaced
12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center
of the sheet.
Base Insulation Laver (Optional)
Any approved Polyisocyanurate
Minimum 1" thick
Top Insulation Laver
Dens Deck, Dens Deck Prime, Securock
Minimum 1A" thick
Fesco Board
Minimum %" thick
High Density Wood Fiber
Minimum %" thick
Insulation Fasteners Fastener
(Table 3) Density /ft2
N/A N/A
Insulation Fasteners Fastener.
(Table 3) Density /ft2
N/A N/A
N/A N/A
N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20 -40 lbs /100 ft2. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top Layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Ply Sheet:
(Optional) One ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex 56,
Elastoflex V, Elastoflex V 2.5, Polybond or one or more plies of Type IV or VI
ply sheet adhered in full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs. /sq.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 9 of 34
Membrane:
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop FR, Elastoshield TSG or
Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General Limitation #7)
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 10 of 34
Deck Type 1I:
Deck Description:
System Type A(2):
Wood, insulated
19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 screws at 6" o.c.
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Anchor Sheet:
Fastening:
One ply of CertainTeed GlasBase, Polyglass Base, Firestone MB Base, JM
Perma -Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the deck as
described below:
Attach base sheet using 11 ga. annular ring shank and 1 -5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in
the center of the sheet.
Base Insulation Laver (Optional)
Insulation Fasteners, Fastener,
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20 -40 Ibs /100 ft2. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Top Insulation Layer
Fesco Board
Minimum 3/4" thick
High Density Wood Fiber
Minimum %Z" thick
Dens Deck, Dens Deck Prime, Securock
Minimum ' /a" thick
Insulation Fasteners Fastener
(Table 3) Densit_v /ft&
N/A
N/A
N/A
N/A
N/A
N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the
EVT range and at a rate of 20 -40 lbs /100 ft2. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base
layers with a second layer of approved top layer insulation installed as the final membrane
substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 11 of 34
Ply Sheet:
Membrane:
(Optional) One ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6,
Elastoflex V, Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet
adhered in full mopping of approved asphalt applied within the ENT range and at
a rate of 20-40 lbs. /sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex 56,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General Limitation #7)
MIAMI DADE COUNTY
APPROVED
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 12 of 34
Deck Type 1I:
Deck Description:
System Type A(3):
Wood, Insulated
19/32" or greater plywood or wood plank.
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Anchor Sheet: One ply of CertainTeed GlasBase, Polyglass Base, Elastobase, Firestone MB
Base, JM Perma -Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the
deck as described below:
Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1 -5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the
center of the sheet.
Fastening #2: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates,
Dekfast #14 with Hex Plates or Tru -Fast HD with MP -3 Plates spaced 12" o.c. in a
4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet.
Base Insulation Laver (Optional)
Insulation Fasteners Fastener
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20 -40 lbs /100 ft2. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Top Insulation Laver
Fesco Board
Minimum 3/4" thick
High Density Wood Fiber
Minimum %z" thick
Dens Deck, Dens Deck Prime, Securock
Minimum '4" thick
Insulation Fasteners Fastener
(Table 3) Density /ft2
N/A
N/A
N/A
N/A
N/A
N/A
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 13 of 34
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the
EVT range and at a rate of 20 -40 Ibs /100 ft2. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base
layers with a second layer of approved top layer insulation installed as the final membrane
substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Ply Sheet:
Membrane:
(Optional) One ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6,
Elastoflex V, Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet
adhered in full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
(.71773"171.
APPROVED
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 14 of 34
Deck Type 1I:
Deck Description:
System Type A(4):
Wood, Insulated
19/32° or greater plywood or wood plank.
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Elastobase or Elastobase P fastened as below:
Fastening: 12 ga. annular ring shank nails and 1 -5/8" tin -caps attached 6" o.c. in 4" lap and
6" o.c. in four equally spaced staggered center rows.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
(Table 3) Density /ft2
ACFoam II, ACFoam III, H- Shield, H- Shield CG, Multi-Max FA3, or ENRGY -3
Minimum 1" thick N/A N/A
Insulation:
Ply Sheet:
Membrane:
Adhered with WeatherTite One -Step Foamable Adhesive, OlyBond 500, Insta-
Stick or TITESET applied in continuous rows 12" o.c.
(Optional) One ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6,
Elastoflex V, Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet
adhered in full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General Limitation #7.)
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 15 of 34
Deck Type 1I:
Deck Description:
System Type B(1):
Wood, Insulated
19/32° or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 screws at 6" o.c.
Base layer of insulation mechanically fastened, optional top layer adhered with
approved asphalt.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
(Table 3) Density /ft2
ENRGY -3, H- Shield or Polytherm
Minimum 1.5" thick 1 or 7 1:1.33 ft2
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners
per board shall be increased maintaining the same fastener density (See Roofing Application
Standard RAS 117 for fastening details).
Top Insulation Laver (Optional)
Insulation Fasteners Fastener
(Table 3) Densitv /ft2
Fesco Board
Minimum %" thick N/A N/A
High Density Wood Fiber
Minimum Y2" thick N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20 -40 lbs /100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanurate face down.
Base Sheet:
Ply Sheet:
Membrane:
(Optional if using ply sheet in hot asphalt) One or more plies of Elastobase,
Modibase, Perma Ply No. 28 or GAFGLAS #75 adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20- 40lbs. /sq.
(Optional if using base sheet in hot asphalt) One or more plies of Polybond, or
Polyflex torch applied or one ply of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex S6, Elastoflex V or Elastoflex V 2.5 or one to more plies of Type IV or
VI ply sheet adhered to the coverboard in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
One ply of Polyflex, Polyflex G, Polyflex G N'R, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 16 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General Limitation #7)
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 17 of 34
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type B(2): Base layer of insulation mechanically fastened, optional top layer adhered with
approved asphalt.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
(Table 3) Density /ft2
ENRGY -3, H- Shield or Polytherm
Minimum 1.5" thick
l or 7 1:1.33 ft2
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners
per board shall be increased maintaining the same fastener density (See Roofing Application
Standard RAS 117 for fastening details).
Top Insulation Laver (Optional)
Fesco Board
Minimum 3 /a" thick
High Density Wood Fiber
Minimum 'h" thick
Insulation Fasteners Fastener
(Table 3) Density /ft2
N/A N/A
N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20-40 lbs /100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanurate face down.
Base Sheet:
Ply Sheet:
Membrane:
(Optional if using ply sheet in hot asphalt) One or more plies of Elastobase,
Modibase, Perma Ply No. 28 or GAFGLAS #75 adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(Optional if using base sheet in hot asphalt) One or more plies of Polybond, or
Polyflex torch applied or one ply of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex S6, Elastoflex V or Elastoflex V 2.5 or one to more plies of Type IV or
VI ply sheet adhered to the insulation in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 18 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 19 of 34
Deck Type 1I: Wood, Insulated
Deck Description: 19132" or greater plywood or wood plank, fastened with wood screws at 6" o.c.
System Type C(1): All layers of insulation are mechanically attached to roof deck. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver (Optional) Insulation Fasteners Fastener.
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1.5" thick
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Laver
High Density Wood Fiber
Minimum Y2" thick
Dens Deck, Dens Deck Prime, Securock
Minimum VP thick
Insulation Fasteners Fastener
(Table 3) Density /ft2
1 1:1.33 ft2
1 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofmg Application Standard RAS 117 for insulation attachment.
Base Sheet:
Ply Sheet:
Membrane:
(Optional if using ply sheet in hot asphalt) One or more plies of Elastobase,
Modibase, Perma Ply No. 28 or GAFGLAS #75 adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(Optional if using base sheet in hot asphalt) One or more plies of Polybond, or
Polyflex torch applied or one ply of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex S6, Elastoflex V or Elastoflex V 2.5 or one to more plies of Type IV or
VI ply sheet adhered to the coverboard in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs. /sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 20 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -82.5 psf; (See General Limitation #7)
MIAMI.DADE COUNTY
APPROVED
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 21 of 34
Deck Type 1I: Wood, Insulated
Deck Description: 19/32° or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
System Type C(2): All layers of insulation are mechanically attached to roof deck. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver (Optional) Insulation Fasteners Fastener
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1.5" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Laver
High Density Wood Fiber
Minimum 1/2" thick
Dens Deck, Dens Deck Prime, Securock
Minimum 1/4" thick
Insulation Fasteners Fastener
(Table 3) Density /ft2
1 1:1.33 ft2
1 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet:
Ply Sheet:
Membrane:
(Optional if using ply sheet in hot asphalt) One or more plies of Elastobase,
Modibase, Perma Ply No. 28 or GAFGLAS #75 adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(Optional if using base sheet in hot asphalt) One ply of Polybond, or Polyflex
torch applied or one ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex
S6, Elastoflex V or Elastoflex V 2.5 or one to more plies of Type IV or VI ply
sheet adhered to the insulation in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20- 40lbs. /sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 22 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -67.5 psf; (See General Limitation #7)
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 23 of 34
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type C(3): All layers of insulation are mechanically attached to roof deck. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver (Optional) Insulation Fasteners Fastener
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1.5" thick
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer
High Density Wood Fiber
Minimum %" thick
Dens Deck, Dens Deck Prime, Securock
Minimum 1/4" thick
Insulation Fasteners Fastener
(Table 3) Density /ft2
1 1:1.33 ft2
1 1:133 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet:
Ply Sheet:
Membrane:
(Optional if using ply sheet in hot asphalt) One or more plies of Elastobase,
Modibase, Perma Ply No. 28 or GAFGLAS #75 adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.
(Optional if using base sheet in hot asphalt) One or more plies of Polybond, or
Polyflex torch applied or one ply of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex S6, Elastoflex V or Elastoflex V 2.5 or one to more plies of Type IV or
VI ply sheet adhered to the insulation in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 24 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 25 of 34
Deck Type 1I:
Deck Description:
System Type D(1):
Wood, Insulated
19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 screws at 6" o.c.
All layers of insulation and base sheet mechanically fastened.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1" thick N/A N/A
Top Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density /ft2
Fesco Board
Minimum 3/4" thick N/A N/A
High Density Wood Fiber
Minimum %" thick N/A N/A
Dens Deck, Dens Deck Prime, Securock
Minimum 1 /4" thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing
membrane at a minimum application rate of two fasteners per board for insulation boards having
no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension
greater than 8 ft.
Base Sheet: One or more plies of Elastobase or Elastobase P fastened to the deck as described
below:
Fastening:
Ply Sheet:
Membrane:
Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates spaced
12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center
of the sheet.
(Optional) One or more plies of Polyflex, or Polybond torch applied or one ply of
Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6, Elastoflex V, or
Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs. /sq..
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 26 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General limitation #7)
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 27 of 34
Deck Type 1I: Wood, Insulated
Deck Description: 19/32° or greater plywood or wood plank.
System Type D(2): All layers of insulation and base sheet mechanically fastened.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
(Table 3) Density /ft2
Any approved Polyisocyanurate
Minimum 1" thick N/A N/A
Top Insulation Laver (Optional) Insulation Fasteners Fastener
(Table 3) Density /ft2
Fesco Board
Minimum 3/4" thick N/A N/A
High Density Wood Fiber
Minimum 1/2" thick
Dens Deck, Dens Deck Prime, Securock
Minimum '4" thick
N/A N/A
N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing
membrane at a minimum application rate of two fasteners per board for insulation boards having
no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension
greater than 8 ft.
Base Sheet:
Fastening
Ply Sheet:
Membrane:
MANMADE COUNTY
APPROVED
One or more plies of CertainTeed GlasBase, Polyglass Base, Elastobase, Firestone
MB Base, JM Perma -Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to
the deck as described below:
Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates,
Dekfast #14 with Hex Plates or Tru -Fast HD with MP -3 Plates spaced 12" o.c. in a
4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet.
(Optional) One or more plies of Polyflex, or Polybond torch applied or one ply of
Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6, Elastoflex V, or
Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs. /sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 28 of 34
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 29 of 34
Deck Type 1: Wood, Non - Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 wood screws at 6" o.c.
System Type E(1): Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase Poly /Sand, Sand/Sand fastened to the deck as described
below:
Fastening: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates spaced
12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center
of the sheet.
Ply Sheet: (Optional) One or more plies of Polyflex, or Polybond torch applied or one ply of
Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6, Elastoflex V, or
Elastoflex V 2.5 or one or more plies of Type W or VI ply sheet adhered in full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs. /sq.
Membrane:
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General Limitation #7)
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 30 of 34
Deck Type 1: Wood, Non - Insulated
Deck Description: 119/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 wood screws at 6" o.c.
System Type E(2): Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
Base Sheet:
One ply of CertainTeed GlasBase, Polyglass Base, Elastobase, Firestone MB
Base, JM Perma -Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the
deck as described below:
Fastening: Attach base sheet using 11 ga. annular ring shank and 1 -5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the
center of the sheet.
Ply Sheet: (Optional) One or more plies of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex 56, Elastoflex V, Elastoflex V 2.5 or one or more plies of Type IV or
VI ply sheet adhered in full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq.
Membrane:
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General Limitation #7)
vi i- •
APPROVED
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 31 of 34
Deck Type 1: Wood, Non - Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type E(3): Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
Base Sheet: One ply of CertainTeed GlasBase, Polyglass Base, Elastobase, Firestone MB
Base, JM Perma -Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the
deck as described below:
Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1 -5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the
center of the sheet.
Fastening #2: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates,
Dekfast #14 with Hex Plates or Tru -Fast HD with MP -3 Plates spaced 12" o.c. in a
4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet.
Ply Sheet: (Optional) One or more plies of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex S6, Elastoflex V, Elastoflex V 2.5 or one or more plies of Type W or
VI ply sheet adhered in full mopping of approved asphalt applied within the EVT
range and at a rate of 20- 40lbs. /sq.
Membrane:
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
NOA No.: 11 -0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 32 of 34
Deck Type 1: Wood, Non - Insulated
Deck Description: 19,32" or greater plywood or wood plank.
System Type E(4): Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening: 11 ga. Annular ring shanked nails and 1 -5/8" tin -caps 6" o.c. in 4" lap and 6" o.c.
in four equally spaced staggered rows. Tin -caps are primed with PG100 primer.
Ply Sheet:
Membrane:
(Optional) One or more plies of Elastobase, Modibase, Perma Ply No. 28,
Elastoflex S6, Elastoflex V, Elastoflex V 2.5 or one or more plies of Type W or
VI ply sheet adhered in full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq.
One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko
Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex 56,
Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR,
Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain
desired coating or required fire classification.
Maximum Design
Pressure: -112.5 psf; (See General Limitation #7)
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 33 of 34
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs. /sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field- tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said
revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
END OF THIS ACCEPTANCE
NOA No.: 11- 0621.07
Expiration Date: 09/13/12
Approval Date: 09/15/11
Page 34 of 34
MMI�DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISSION
NOTICE OF ACCEPTANCE (NOA)
MIAMI-DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375 -2908
Clay Forever, LLC
6801 NW 77a` Avenue
Miami, FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Altura "S" Clay Roof rile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA #06 -0706.09 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category:
Sub - Category:
Material:
Roofing
Roofing Tiles
Clay
1. SCOPE
This renews roofing system using Altusa One Piece S' Clay Roof Tiles, as manufactured by
Alfareria Del Turbio, S.A. (ALTUSA) in Venezuela and described in Section 2 of this Notice of
Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be done as a
moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Altusa One Piece `5'
Tile
Trim Pieces
Clip
Clip
Dimensions
L= 18',4"
W = 10.5"
'h" thick nominal
3.25" high
Length: varies
Width: varies
varying thickness
L = 6"
D= 0.125"
L &h =2"
W ='/i"
0.05" thick
2.1 SUBMITTED EVIDENCE:
Test Agency
IBA Consultants, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation Testing
Test Product
Specifications Ilescription
TAS 112
TAS 112
TAS 114
TAS 114
Test Identifier
2397 -116
94-083
94-084
25- 7200 -1
Project No. 307025
Test #MDC -78
MTS 520649
High profile clay roof tile. For direct deck or
batten nail -on, mortar set or adhesive set
applications with minimal headlap of 2-'/z"
Accessory trim, clay roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Tile clip
L Shaped tile clip
Test Name/Report Date
ASTM C 1167 06/28/07
Static Uplift Testing April 1994
TAS 101 (Adhesive Set)
Static Uplift Testing May 1994
TAS 101 (Mortar Set)
Static Uplift Testing Feb. 1995
TAS 102
(Quick-Drive Screws,
Battens)
Wind Driven Rain • Oct. 1994
TAS 100
TAS 102(A) May 2000
NOA No.: 07-0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 2 of 7
Test Agency
PRI Asphalt Technology, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Test Identiiierr
CLF-003-02 -01
7161 -03; Appendix III
7161 -03
Appendix II
Letter Dated Aug. 1,
1994
P0631 -01
P0402
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with RAS 106.
3.3 Applicant shall retain the services of a Miami Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum imderlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 `Altura One Piece S' Clay Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Test Name/Report
TAS 102
TAS 102
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Aerodynamic Multiplier
25 -7183
25 -7094
25-7496
25 -7584
25- 7804b -8
25- 7804 -4 & 5
25- 7848 -6
Date
October 2001
Dec. 1991
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
March 1999
March 1995
February 1996
April 1996
December 1996
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 3 of 7
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight- W'(Ibf)
Length -I (ft)
Width -w (ft)
Altusa `S' Tile
6.9
1.52
0.875
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf
Tile
Profile
Table 2: Aerodynamic Multipliers - X (ft3)
4": 12"
Tile
6": 12"
I►. (ft3)
X (ft3)
Battens
Profile
Battens
Batten Application
Direct Deck Application
Altusa `S' Tile
Battens
Direct
Deck
0.253
0.274
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf
Tile
Profile
3": 12"
or less
4": 12"
5 " :12"
6": 12"
7 ":12" or
greater
Altusa `S' Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
4.47
5.35
4.40
5.27
4.31
5.16
4.20
5.03
4.08
4.89
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft Ibf)
for Nall -On Systems
Tile
Profile
Fastener Type
Direct Deck
(Min 15/32"
plywood)
Direct Deck
(Min. 19/32"
plywood)
Battens
Altusa 'V Tile
2 -10d Ring Shank Nails
28.6
41.2
19.4
1 -10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2 -10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 . #8 Screw
28.7
28.7
N/A
2 . #8 Screws
58.2
58.2
26.8
1 -10d Smooth or Screw
Shank Nail (Field Clip)
23.1
23.1
19.0
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
29:3
29.3
24.0
2 -10d Smooth or Screw
Shank Nails (Field Clip)
27.6
27.6
38.6
2 -10d Smooth or Screw
Shank Nails (Eave Clip)
38.1
38.1
41.8
1 Screw with Altusa Clip (See c
ip details)
Altusa "S"
Tile'
1 Screw with clip (at the
head of tile)
187.1
187.1
N/A
Altusa "S"
Tile'
1 Screw with clip (at the
water course of tile)
35.2
35.2
N/A
1. Screw must be installed In the inside nail hole located nearest to the hump of the tile.
NOA No.: 07-0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table 6:
Attachment
Mr (ft-lbf)
Resistance Expressed as a Moment
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Altusa 'S' Tile
Adhesive
29.3d
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 10.7 grams.
Potyfoam Product, Inc. Average weight per patty 8 grams.
Table 7: Attachment Resistance Expressed as a Moment - M1 (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Altusa '8' Tile
Palyfoam PoIyProTM
66.54
Polytoam PolyProTM
38,7b
4 Large paddy placement of 83 grams of PolyProTM.
5 Medium paddy placement of 24 grams of PolyProTM.
Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Altusa 'S' Tile
Mortar Set
24.50
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or
following statement: "Miami -Dade County Product Control Approved ".
SIC SIC SIC
ALTUSA MADE IN VENEZUELA SIC SIC SIC
IDENTIFICATION MARK FOR ALTUSA `S' CLAY ROOF TILE
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building
code in order to properly evaluate the installation of this system.
NOA No.: 07-0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 5 of 7
PROFILE DRAWINGS
ALTUSA `S' CLAY ROOF TILE
'SPANISH S°
TILE BY ALTUS
(TYP.)
CLIP DETAILS
2 -1/2" OVERLAP
(COVERS PIN HOLE)
SCREW IN THE INSIDE HOLE
NEAREST TO THE HUMP OF THE TILE
DECK'
CLIP WITH ONE (1) SCREW
ATTACHED TO DECK
CLIP
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 6 of 7
SCREW (HOLDS
CUP ONTO DECK)
'SPANISH S"
TILE BY ALTUSA
CrTIN
CLIP DETAILS (CON'T)
2 OVERLAP
(COVERS PIN
HOLE)
SCREW IN THE INSIDE NAIL HOLE
NEAREST TO THE HUMP OF THE TILE
CUP PLACEMENT DETAIL
DECK
! 1 1/4" ! 1 W4° 3/4°
END OF THIS ACCEPTANCE
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12120/07
Page 7 of 7
MIAMI DE
COUNTY
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyfoam Products, Inc.
11715 Bordeaux Road
Tomball, TX 77375
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.minmidade.gov /build ins/
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Section and accepted by
the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and /or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code,
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyset® One Roof Tile Adhesive
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement; "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOM 09- 0622.04 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 10- 1112.05
Expiration Date: 01/03/16
Approval Date: 01/06/11
Page 1 of 5
ROOFING ASSEMBLY APPROVAL:
Category: Roofing
Sub Category: 07320 Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves Polyset® One as described below in this Notice of Acceptance, designed to comply with
the Florida Building Code. For the locations where the pressure requirements, as determined by
applicable building code, do not exceed the design pressure values; as obtained by calculations in
compliance with RAS 127, using Polyset® One, and where the attachment calculations shall be done as
an moment based system.
PRODUCTS MANUFACTURED BY APPLICANT:
Product
Polyset® One
dimensions
Factory premixed canisters
MANUFACTURING LOCATION:
1. Norton, OH.
PHYSICAL PROPERTIES:
Property
Density
Compressive Strength
Tensile Strength
Water Absorption
Moisture Vapor Transmission
Dimensional Stability
Closed Cell Content
EVIDENCE SUBMITTED:
Test Agency
Southwest Research Institute
PRI Construction Materials
Technologies, Inc.
Product Description
Single component polyurethane foam roof tile
adhesive.
Test
ASTM D 1622
ASTM D 1621
ASTM D 1623
ASTM D 2842
ASTM E 96
ASTM D 2126
ASTM D 2856
Results
1.95 lbsfft 3
7.8 psi
15 PSI Parallel to rise
4.6 LbsJFt2
1.94 Perm / Inch
+0.89% Volume Change ® 70° C., 2 Weeks
54,1%
Test Identifier Test Name/Report
01- 1208 -025 ASTM E 108
FOP - 009-02 -10 Physical Properties
FOP- 009 -02 -01 TAS -101
FOP - 009 -02-02 TAS -101
FOP - 009 -02-03 TAS -101
FOP - 009 -02-04 TAS -101
FOP-009-02-05 TAS -101
Date
06/16/98
12/14/10
11/8/10
11/4/10
11/8/10
11/8/10
11/8/10
NOA No.: 10- 1112.05
Expiration Date: 01/03/16
Approval Date: 01/06/11
Page 2 of 5
LINIITATIONS:
I. Fire classification is not part of this acceptance.
2. Polyset® One can be used with flat, low, medium and high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of Polyset® One roof the adhesive with
their tile assemblies shall test in accordance with TAS 101 with section 10A as modified herein.
F'— MS
W
2
INSTALLATION:
I. Polyset® One may be used with any roof tile assembly having a current NOA that lists moment
resistance values with the use of Polyset® One
2. Polyset® One shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with
the use of Polyset® One shall provide sufficient attachment resistance, expressed as a moment
based system, to meet or exceed the moment resistance determined in compliance with Roofing
Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly
NOA
3. Polyset® One roof tile adhesive and its components shall be installed in accordance with Roofing
Application Standard RAS 120, and Fomo Products, Inc. Polyset® One Operating instruction and
Maintenance Booklet
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam
Products, Inc.
5. Pressure treated wood fllcr block shall be required on all nave course of all tile profiles except on
two pieces barrel tile.
6. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after Polyset®
One has been dispensed.
7. Polyset® One placement shall be in accordance with the 'Placement Details' herein. Each generic
tile profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile
Profile
Typical Placement
Detail
Weight per paddy
(grams)
Flat, Low & High Profile
# 1
12
High Profile 2 -Piece
Barrel
# 2
12
LABELING:
All Polyset® One containers shall comply with the Standard Conditions listed herein.
MIAMFDADE+C
• 1*
APPROVED
NOA No.: 10-1112.05
Explratlon Date: 01/03/16
Approval Date: 01/06/11
Page 3 of 5
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the
installation of this system.
ADHESIVE PLACEMENT DETAILS
■
BEAD IN TREPAN
I:oNTINDOUB WITH
AOHEBABEONOEON.
CUT AWAY VIEW
1
PLACEMENT DETAIL # 1
NOA No.: 10-1112.05
Expiration Date: 01/03/16
Approval Date: 01/06/11
Page 4 of 5
ADHESIVE PLACEMENT DETAILS
(CONTINUED)
PLACEMENT DETAIL # 2
END OF THIS ACCEPTANCE
NOA No.: 10- 1112.05
Expiration Date: 01/03/16
Approval Date: 01/06/11
Page 5 of 5
AUG 1 220„
V ti-
FPL.
*********************AUTO"5 -DIGff 33138 T62 P1
Sallesh Mehta
10480 NE 5th Ave
Miami Shores, FL 33138 -2040
06/27/2011
ENERGY
smart
FLORIDA
Account No: 6403188904
You're now part of a smarter grid
Dear Sailesh Mehta,
Our customers have told us that reliable and affordable electricity is what's
important to them. And we're committed to delivering just that. Now, using state -
of -the -art smart grid technologies, we're doing even more to keep your service
reliability high and help you gain more control over your electric bill.
We've replaced the meter on your property with a smart meter
The new meter is an essential part of our commitment to building a stronger,
smarter, cleaner and more efficient electric grid. Here's how we're putting these
new technologies to work for you:
A smarter, stronger grid for the way you live
Smart technologies will help us keep your service reliability among the highest in the
nation. They will make it possible for us to offer you a wide range of benefits in the
future, including fewer power outages and faster service restoration when an outage
rinse nrra it
Mope information to help you take more control over the energy you use
in addition, the new smart meter provides you with more information than ever
More about the energy you use. Instead of waiting until you receive your monthly
FPL bill to see how much electricity you have used, you can log on to our secure
website and see how much energy you're using, as well as what you're spending for
it, by the month, day or even by the hour. The meter is smart, but you're in control.
If you so choose, you can use this information along with our Home Energy Survey
and conservation tips, also on our website, to actively manage your energy use and
save on your bill.
Whether or not you choose to manage your energy use on www FPLcom, the
smart meter provides other advantages to you, such as convenience. clue w 1 no
longer need access toyourproperty to read the- meterbecause -the smart meter
communicates remotely with FPL(We will still need occasional access for routine
maintenance.)
Learn more at www.FPLcom/smartmeter and sign up to receive a -mails with
energy - saving tips.
Sincerely,
Marlene Santos
Vice President of Customer Service
Take the steps to reduce your
energy and you'll be on your way to
saving electricity and money.
Page 1 of 1
FPL Correspondence
FPL_Customer_Correspondence
to:
sailesh.mehta
06/24/2011 04:19 PM
Sent by:
FPL_Correspondence @fpl.com
Please respond to FPL_Customer_Correspondence
Show Details
June 24, 2011
SAILESH MEHTA
10480 NE 5TH AVE
MIAMI SHORES FL 33138
Re: BILL ACCOUNT #: 6403188904
10480 NE 5TH AVE
MIAMI SHORES FL 33138
Dear Sailesh Mehta:
Thank you for your recent concern with ensuring we get an accurate reading 011 your Smart Meter.
Our records show, on May 26, 2011, we activated your area on a certified route. This means we have the ability to read your
meter remotely and get actual meter readings every month without inconveniencing you (We will occasionally still need to
access the meter to perform routine maintenance). Until the meter is activated, which can take several months, we will
continue to read your meter in- person and will need to estimate your bill if we are unable to safely access and read your
meter.
iOn June 16, 2011, we were able to get an accurate remote reading: jIf you have recently enclosed your meter are and are
concerned with providing FPL access to your meter area in the event we need to take a physical reading, please provide us
with access instructions.
Should you have any questions regarding this matter, please do not hesitate to contact us at 305 -442 -8770.
Sincerely,
FPL Customer Care Center
file: / /C:\Documents and Settings\mo0155\Local Settings \Temp\notesClEE6A \— web3284.htm 6/24/2011
(pal
Permit No: 11 -1014
Job Name:
August 19, 2011
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Page 1 of 1
Building Critique Sheet 2nd
1) All permit applications must be submitted prior to any further review.
The code design criteria are incorrect and the wind load design criteria are incomplete on
plans.
3) Details 1 and 2 conflict. The existing beam is level but the roof is sloped. How will the
out - lookers in detail one be attached to a level beam.
e a separate roofing application. A complete HVHZ Roofing Application is
required.
Plan review is not complete, when all items above are corrected, we will do a complete plan
review.
If any sheets are voided, remove them from the plans and replace with new revised sheets and
include one set of voided sheets in the re- submittal drawings.
Norman Bruhn CBO
305 - 795 -2204
FAA; a)5- --7b2.
08/22/2011 14:05 FAX 1 800 685 7530
DATA SCAN FIELD SERVICES
001.
* * * * * * * * * * * * * * * * * * * **
*s* TX REPORT * **
* * * * * * * * * * * * * * * * * * * **
TRANSMISSION OK
TX /RX NO 1697
RECIPIENT ADDRESS 93052527029
DESTINATION ID
ST. TIME 08/22 14:04
TIME USE 01'05
PAGES SENT 3
RESULT OK
Permit No: 11 -1014
Job Name:
August 19, 2011
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Page 1 of 1
Building Critique Sheet 2nd
1) All permit applications must be submitted prior to any further review.
2) The code design criteria are incorrect and the wind load design criteria are incomplete on
plans.
3) Details 1 and 2 conflict. The existing beam is level but the roof is sloped. How will the
out - lookers in detail one be attached to a level beam.
4) Provide a separate roofing application. A complete HVHZ Roofing Application is
required.
Plan review is not complete, when all items above are corrected, we will do a complete plan
review.
If any sheets are voided, remove them from the plans and replace with new revised sheets and
include one set of voided sheets in the re- submittal drawings.
Norman Bruhn CBO
305 - 795 -2204
FAA. aN,5-?5?‘
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Permit No. j l `') 01 4'
Job Name ,j 7J
Date81`tof'd
STRUCTURAL CRITIQUE SHEET
volt, G OPtr f hYV cH o eno watt.
sect' 1 tin i --. r h o w f � a oh 7, ob • C gel riF
a14d Ile PiIC 44 ie - sse),OecThe cff, each state
of''toor if 34" wletortmore. ef
oehwj /kacvnew oisNAr'e corghecpeala
eke/ ` -- Ifer 1a
Planning and Zoning Criteria
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138 -0000
Phone: (305)795 -2204 Fax: (305)756 -8972
Permit NO. RC -6 -11 -1014
VOgiX
Issue Date: Not Issued
Explres:NOt Issued
Folio Number:1122310150010
Owner's Name: SAILESH MEHTA
Job Address: 10480 5 Avenue
Miami Shores, FL 33138-
Owner's Phone: (305)491 -5729
Total Square Feet: 137
Total Job Valuation: $ 1,000.00
Planning and Zoning Criteria and Comments
Approved: Yes Date Approved: 8/15/2011: Yes
Comments: FLAT ROOFS THAT ARE VISIBLE FROM THE FRONT STREET ARE NOT ALLOWED.
8/15/11
NEW PLANS SHOW SLOPE ROOF OK
Permit No: 11 -1014
Job Name:
June 17, 2011
Miami Shores Village
9
Building Department
Building Critique Sheet
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
°-- 1) Impact fees must be paid with Miami Dade County planning and zoning.
,.2) All permit applications must be submitted prior to any further review.
3) Corrections for ZONING and electrical must be completed.
4) Provide the code design criteria and the wind load design criteria onplans.
` 5) Show the size of the existing door.
6) The roof sheathing details conflict.
7) The roofing material detail does not comply with the code.
' 8) Provide a separate roofing permit application.
Page 1 of 1
NO FURTHER REVIEWS WILL BE COMPLETED UNTIL A ZONING APPROVAL IS ISSUED
Plan review is not complete, when all items above are corrected, we will doa complete plan
review.
If any sheets are voided, remove them from the plans and replace with new revised sheets and
include one set of voided sheets in the re- submittal drawings.
Norman Bruhn CBO
305 - 795 -2204
CPA 24, I ,, _f, ruii:T co
Planning and Zoning Criteria
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138 -0000
Phone: (305)795 -2204 Fax: (305)756 -8972
PermitNO. RC -6 -11 -1014
Issue Date: Not Issued
Expires:Not Issued
Folio Number:1122310150010
Owner's Name: SAILESH MEHTA
Job Address: 10480 5 Avenue
Miami Shores, FL 33138-
Owner's Phone: (305)491 -5729
Total Square Feet: 137
Total Job Valuation: $ 1,000.00
Planning and Zoning Criteria and Comments
Approved: No Date Denied: 6/3/2011
Comments: FLAT ROOFS THAT ARE VISIBLE FROM THE FRONT STREET ARE NOT ALLOWED.
Miami Shores Viiiage
Building Department
RECEIPT
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
PERMIT #: vcl1 -I0I4 DATE: 00*C--2 ada)011
ntractor
w d'wner
❑ Architect
Lt
up 2 sets of plans and
Address: 1 °i-
er) O w \O) 000,6\ons_
From the building department on this date in order to have corrections done to plans
And /or get County stamps. I understand that the plans need to be brought back to Miami
Shores Village Building Department to continue permitting process.
Acknowledged by:
PERMIT CLERK INITIAL:
RESUBMITTED DATE: 8
PERMIT CLERK INITIAL:
PERMIT #:
(k (bly
IVI iami Shores Viiia e
9
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
RECEIPT
DATE: L
❑ Contractor
-Owner
❑ Architect
Picked up 2 sets of plans and (other)
L(Z-a1,--C770Nr
Address: /0 Li d'a A-7L- 1-WC
From the building department on this date in order to have corrections done to plans
And/or get County stam,'s.1 understand that the plans need to be brought back to Miami
Shores Village Building Depa - it to continue permittin. -
Acknowledged by:
PERMIT CLERK INITIAL:
RESUBMITTED DATE: ctl*D ii
PERMIT CLERK INITIAL: