RF-10-1802Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 155697 Permit Number: RF -10 -10 -1802 Scheduled Inspection Date: February 07, 2011 Inspector: Bruhn, Norman Owner: LENZ, JOSE Job Address: 965 NE 92 Street Miami Shores, FL Project: <NONE> Contractor: MAINLAND CONSTRUCTION CO Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile ekomill Phone Number arcel Number 1132060060040 Phone: 305 - 225 -5571 Building Department Comments RE -ROOF FLAT WHITE TILE Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 152185. No ladder or plans posted NB February 04, 2011 For Inspections please call: (305)762 -4949 Page 29 of 34 J C A. R L A I N C. moil November 1, 2010 Mainland Roofing Company 3740 NW 80 St Miami, FL 33147 RE: TILE UPLIFT TEST PROJECT INFORMATION PROVIDED BY THE CLIENT: 965 NE 92 St Miami Shores, Florida Folio#: 11- 3206 - 006 -0040 Permit #: RF -10 -10 -1802 Date inspected: October 29, 2010 Date completed by: October 26, 2010 Roofing Contractor: Mainland Roofing Company Carlab, Inc Project # 10 -6314 Testing lab Certificate #: 09- 0127.04 Dear Sirs, In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 2400 square feet, and the mean height of the roof is less than 30 feet above ground surface. The type of tile used for this project was reported to be Eagle Bel -Air Roof Tile. This tile was reported to have been foamed in place. At the time of this testing, one test for every corner, one test for every 100 square feet of roof tile in the perimeter area and one test for every 200 square feet of roof tile in the field area were tested. Initially the entire area of the roof was examined for loose tile. More than 10% of the roof tile located in the field area and more than 20% of the roof tile at the roof perimeter and corner were physically examined. The results for this report are valid at the time of testing only. Walking on roof or any other type of physical disturbance may alter these results. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above mentioned protocol. Attached please fmd a copy of our test report for your review. Should you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully bm itted, //74,1 Sergio Labiste, PE 61733 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438 Test Test load (lbf) Test Status 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass 9 35 Pass 10 35 Pass 11 35 Pass 12 35 Pass 13 35 Pass 14 35 Pass 15 35 Pass 16 35 Pass 17 35 Pass 18 35 Pass 19 35 Pass 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 24 35 Pass 25 35 Pass 26 35 Pass 27 35 Pass 28 35 Pass 29 35 Pass 30 35 Pass 31 35 Pass 32 35 Pass 33 35 Pass 34 35 Pass 35 35 Pass 36 35 Pass TILE UPLIFT TEST FOR Residential Home 965 NE 92 St Miami Shores, FL Project #: 10 -6314 Test Test load (lbf) Test Status 37 35 Pass 38 35 Pass 39 35 Pass 40 35 Pass 41 35 Pass 42 35 Pass 43 35 Pass 44 35 Pass 45 35 Pass 46 35 Pass 47 35 Pass 48 35 Pass 49 35 Pass 50 35 Pass 51 35 Pass 52 35 Pass 53 35 Pass 54 35 Pass 55 35 Pass 56 35 Pass 57 35 Pass 58 35 Pass 59 35 Pass 60 35 Pass 61 35 Pass 62 35 Pass 63 35 Pass 64 35 Pass 65 35 Pass 66 35 Pass 67 35 Pass 68 35 Pass 69 35 Pass 70 35 Pass 71 35 Pass 72 35 Pass Test Test load (lbf) Test Status 73 35 Pass 74 35 Pass 75 35 Pass 76 35 Pass 77 35 Pass 78 35 Pass 79 35 Pass 80 35 Pass 81 35 Pass 82 35 Pass 83 35 Pass 84 35 Pass 85 35 Pass 86 35 Pass 87 35 Pass 88 35 Pass 89 35 Pass 90 35 Pass 91 35 Pass 92 35 Pass 93 35 Pass 94 35 Pass 95 35 Pass 96 35 Pass 97 35 Pass 98 35 Pass 99 35 Pass 100 35 Pass 101 35 Pass 102 35 Pass 103 35 Pass 104 35 Pass 105 35 Pass 106 35 Pass 107 35 Pass 108 35 Pass 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438 Test Test load (lbf) Test Status 109 35 Pass 110 35 Pass 111 35 Pass 112 35 Pass 113 35 Pass 114 35 Pass 115 35 Pass 116 35 Pass 117 35 Pass 118 35 Pass 119 35 Pass 120 35 Pass 121 35 Pass 122 35 Pass 123 35 Pass 124 35 Pass 125 35 Pass 126 35 Pass 127 35 Pass 128 35 Pass 129 35 Pass 130 35 Pass 131 35 Pass 132 35 Pass 133 35 Pass 134 35 Pass 135 35 Pass 136 35 Pass 137 35 Pass 138 35 Pass Test Test load (lbf) Test Status Test Test load (lbf) Test Status 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438 4 . LEGEND + FIELD TEST - PERIMETER TEST O CORNER TEST CARL A B, I N C. Aim AND FLAMM Hamm a AVIIIS IZASSON em ado &W. a !F.111■14 PL 33866'II7, DS ]Deals PAID DS areas 34 + + +- — T + ++ _ + ++ - + ++ + + ++ + +.+ + + APPROX. ROOF TEST LOCATIONS AND DIMENSIONS I