Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-12-920
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 173887 Permit Number: RF -5 -12 -920 Scheduled Inspection Date: June 25, 2012 Inspector: Bruhn, Norman Owner: DAY, VIRGINIA WILDS Job Address: 70 NW 102 Street Miami Shores, FL 33150- Project: <NONE> Contractor: DALEY ROOFING INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1131010180160 Phone: (305)754 -9892 Building Department Comments REMOVE 30 -50 TILES FROM CHIMNEY AREA, REPLACE DAMAGED LUMBER, REFLASH CHIMNEY INSTALL NEW UNDERLAYMENT AND REPLACE TILE WHERE REMOVED Passed rr o�- Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Gc June 22, 2012 For Inspections please call: (305)762 -4949 Page 15 of 43 Miami Shores Village Building Department 1,1),T© I ;I MAY 22 262 PI 8 Y: 0Y--- _4e9omeo°aoe°o 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 5 1 2» (2 Pr)ti INSPECTION'S PHONE NUMBER: (305) 762.4949 ° nn BUILD G Permit No 19. 9 PERMIT APPLICATION Master Permit No. FBC 20 Permit Type: BUILDING OWNER: Name (Fee Simple Titleholder): W /t6 //1/ // Dom% Phone #: Address: 70 /fit) iD t 5t City: /Ljte i'// S 'O State: i'l - Zip:ca &>Z Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: 70 A4) `01- Si- City: Miami Shores Folio/Parcel #: County: Miami Dade Zip: .3 3 / Is the Building Historically Designated: Yes NO t s Flood Zone: CONTRACTOR: Company Name: 2 g A.76 %BI✓C Phone #:.3 75Y 9e19-- Address: 7cf / 1®E0 ' City: f 477'7 _. L1T State: Qualifier Name: y' Phone #: Zip: :513g State Certification or Registration #: WegiOt 719D Certificate of Competency #: Contact Phone #: Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $12,517-- Square/Linear Footage of Work: 416 Type of Work: DAddition OAlteration New ORepair/Replace ODemolition Description of Work: te7nrye O 5V 77 LE snivel - IWLI9(,6 b477 6622 -17 LE Gv P �l'w1Yt� **+ x********* ** ********u:*******+x******* *Fes **** :******** ******** ** **** **********+x**** Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ ' IAD Bonding Company's Name (if applicable) Bonding Company's Address City St Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection tll t be approve and a reinspection fee will be charged. Signature '\� D Owner or Agent The foregoing instrument was acknowledged Day me this /1 day of ,20l� -,by VtCogVlIC. Doy ho is personally known to n )or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: Contractor The foregoing instrument was acknowledged beftre day of L A , 20 1 ,X, by ^S� who 's-persona nown to me or who has pry duced as identification and who did take an oath. NOTA PUBLIC: Sign: APPROVED BY ,7,4(22''- Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) CLAUDIA V, CUBILLOS gtate of U • I My Comm. BY e�eQ 23, 2015 • My Co X 128810 Commission # EE 120ssn. Bonded 'Through National Notary Zoning Clerk a ROOF ASSENBUES AND $OOFTOP STRUCTURES Florida Building Code Edition 200 High-Velocity Hurricane Zone Uniform Pemdt Application Seetinn A /General $nfnnnatinn) 1°INIJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS VMaster Permit No. Process No. Contractor's Name //n�a-�' / 142/9-&A/0 AC/ Job Address V© AA) /0?- ❑ Low Slope ❑ Asphaltic Shingles O Mechanically Fastened Tile I:Warie r/Adhesive Set Tile O Metal Panel/Shingles ❑ Wood ShingleslShakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof ❑ Reroofing ❑ Recovering Q" Repair 0 Maintenance ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) Total (SF) 07 Low Slope Roof Area (SF) SBCtinn B (Rs n Plan) Sketch Roof Plan: fllustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. x1e @r FLORIDA BUILDING CODE — BUILDING //N. ti SECTION R4402.13 HiGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13,1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics-Workmanship: the workmanship provisions of Section R4402 -are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. —' "' Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). Common roofs: Common roofs are those which have no visible delineation between neighboring units (i. :., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be vi from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. W s - Ponding water: The current roof system and/or deck of the building may not drain well and may cause er to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. - JOverflow scuppers (wail outlets): It is required that rainwater flows off so that the roof is not overload from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior o the structure assembly (the building itself). The existing amount of attic ventilation shall not be uced. may be beneficial to consider additional venting which can result in extending the service life of the roof. 's Signature Date Revised on 7/9/2009 LD 5/P1 Contractor Signature Date