Loading...
RC-12-439Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number INSP- 171080 Permit Number: RC- 3- 12-439 Scheduled Inspection Date: June 06, 2012 Inspector. Bruhn, Norman Owner: HOWARD, DAVID Job Address: 55 NE 97 Street Miami Shores, FL 33138- Project <NONE> Contractor: PRESTIGE SOLAR Permit Type: Residential Construction Inspection Type: Final Work Classification: Solar Phone Number (305)968 -2445 Parcel Number 1132060130990 Phone: (305)827 -1935 Building Department Comments REPLACE WATER HEATER TO SOLAR Inspector Comments ‘‘--a Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. June 05, 2012 For Inspections please call: (305)762 -4949 Page 4 of 17 Miami Shores Village • Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 \ it, BUII.DIN PE FBC 3 TL. PLICATION Permit No. Master Permit NoP 2 - l (2. 9 Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): DcA.Vid4 F d Phone#: Address: '55 IV6 9°1 fit' City: Marni 'ems State: Fl Zip: ?)3t38 Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: 5,5 t'.Y City: Miami Shores County: Miami Dade Zip: P-13 tS Folio/Parcel #: 1 t - 59,c :o -of 3 Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name:_______ Phone#: (5=1'5") ") Sal scr.. Address: 601 5.:7 ►\K kdl fit-• City: M��i�► State: 1 Qualifier Name: ��c him UU 2c Zip: Phone#: 30 S 8-2-7 ! 53 5 State Certification or Registration #: CA/ C. % (476'j Certificate of Competency #: Contact Phone #: 305 V7-7 l'135 Email Address:. DESIGNER: Architect/Engineer: e 24 fin ,, Phone#: • g/3 4'3b % 2f(e Value of Work for this Permit: $ 35b0 Square/Linear Footage of Work: ONew DRepair/Replace DDemolition Type of Work: DAddition ®Alteration Description of Work: �1� YVD, C,.R '�iC -t�JC' -It \cur Submittal Fee $ v ® Permit Fee $ /D) CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ [ l ' 900 4 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SINS, WELLS, POOIS, FURNACES, BOILERS, BEATERS, TANKS and AIR CONDITIONERS, FTC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and rotting. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment Atso, a certified copy of the recorded notice of commencement must be posted at the job site for the first ' ection which occurs seven (7) days after the building permit is issued In the absence off;'. posted notice, the inspection will ' t be approved a reinspection fee will be charged. Signatu er or Agent The foregoing instrument was acknowledged before me this 2A day of ,Fe , 20 f by v i cP 1-10Ws rct _ who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: VANESSA t30MF2 MY COMPASSION #EE149306 EXPIRES: NOV 28, 2015 anted through 1st Stets Insurance Sign: / a(/.-77,c Print: My Commission Expires: APPROVED BY Signature NO 44111P Contractor The foregoing instrument was acknowledged before nu; this day of F- 20 I 2-, by c' i 5h rt4 SCAVk z who is personally known to mm or who has produced as identification and who did take an oath. NOTARY PUBLIC: sign: Print: VANESSAq0MEZ MY COMMISSION #EE149306 EXPIRES. NOV 28, 2015 nded through let Std hawan My Commission Expires: 1J* * :10 * *** * ** M:'st:+rt** * ****0* ******* **** 4 -08***** **** n**** * *****************i* 2020FlansExamirrer � Zoning Structural Review Clerk (Revised 07/lO!07)fReviscd 06/10/2009)(Revised 3/15109) 1 Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Folio Number:1132060130990 Owner's Name: DAVID HOWARD Job Address: 55 97 Street Miami Shores, FL 33138- Owner's Phone: (305)968 -2445 Total Square Feet: 40 Total Job Valuation: $ 3,500.00 Contractor(s) PRESTIGE SOLAR Phone Primary Contractor (305)827 -1935 Yes Planning and Zoning Criteria and Comments Approved: Yes Date Approved: 3/15/2012: Yes Comments: SOLAR PANEL AT REAR OF HOUSE z in S8 T 1{ t ,. r1 '. K ERAEr N g 8 _.rrna- tn V O CD rt r) n a —n w (cw 00 C MT :LCJ2 -ya`iJ Shores Village Miami APPROVED BY DATE ZONING DEP'r liri , " FrAgra BLDG DEPTM FEDERAL SUBJECT 10 CCAIPL.IANCE WI 11-1 ALL STATE ANL) Cr UN 1 1 RILES AND REGULATIONS SOLAR COLLECTOR CER'I 'N ED SOLAR COLLECTOR CERTIFICATION AND RATING SUPPLIER: SRCC OG -100 Alternate Energy Technologies • AE-40 Alternate Energy Technologies 1057 N. Ellis Road Jacksonville, FL 32254 MODEL: COLLECTOR TYPE: CERTIFICATION #: Alternate Energy AE -40 Glazed Flat -Plate 100- 2002 -001F COLLECTOR'1'.HERMAL PERFORMANCE RATING Megajoules Per Panel Per Da CATEGORY CLEAR MILDLY ( Ti -Ta) DAY CLOUDY 23 MJ /m2•d 17 MJ /m2•d A ( -5 °C) B (5 °C) C 20 °C D 50 °C CLOUDY DAY 11 MJ/m2.d CATEGORY ( Ti -Ta) A ( -9 °F) B (9 °F) C 36 °F Thousands of Btu Per Panel Per Da CLEAR DAY 2000 Btu/ft2.d 52 39 47 35 40 27 MILDLY CLOUDY 1500 Btu/ft2.d CLOUDY DAY 1000 Btu/ft2.d 27 22 I5 E (80 °C) 10 1 13 E (I44 ° F) 9 1 A -Pool Heating (Warm Climate) B -Pool Heating (Cool Climate) C -Water Heating (Warm Climate) D -Water Heating (Cool Climate) E -Air Conditioning Original Certification Date: November 22, 2002 COLLECTOR SPECIFICATIONS Gross Area: 3.696 m2 39.78 ft2 Dry Weight: 69.4 kg 153 lb Test Pressure: 1103 kPa 160 psig 3 COLLECTOR MATERIALS Frame: Cover (Outer): Cover (Inner): Absorber Material: Absorber Coating. Insulation (Side): Insulation (Back): Anodized Aluminum Low Iron Tempered Glass None Tube - Copper / Plate - Copper Fin Selective Coating Polyisocyanurate Polyisocyanurate TECHNICAL INFORMATION Efficiency Equation [NOTE: (P) = Ti -Taj S I Units: ti = 0.691 - 33960 (P)/I I P Units: ri = 0.691 - 0.5985 (P)/I Incident Angle Modifier [(S) = 1/cos 0 -1, 0 °5 0 001 Ka = 1.0 - 0.1939 (S) - 0.0055 (S)2 K = 1.0 -0.20 (S) (Linear Fit) REMARKS: Net Aperture Area: 3.481 m2 Fluid Capacity: 6.1 1 Max. Oper. Temp.: 176.7 °C ml/s 37.47 ft2 1.6 gal 350 °F PRESSURE DROP Flow A P gpm Pa in H2O Y Intercept Slone, - 0.0019 (P)2/I 0.706 - 4.9099 W /m2• °C - 0.0002 (P)2/I 0.706 -0.865 Btu/M.12.°F Model Tested: AE -21 Test Fluid: Water Test Flow Rate: 39 mI/s 0.62 gpm October, 2004 Certification must be renewed annually. For current status contact: SOLAR RATING & CERTIFICATION CORPORATION c/o FSEC • 1679 Clearlake Road • Cocoa, FL 32922 • (321) 638 -1537♦ Fax (321) 638 -1010 FSEC # S9105 FLORIDA SOLAR ENERGY CENTER° Approved Solar Energy System Approval Date: Dec 1991 Revision Date: Jan 2012 DISTRIBUTOR SYSTEM The LeverEdge OPV -66 -32 1423 Gunn Highway Odessa, Florida 33556 This system was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida Standards Program for Solar Domestic Water and Pool Heating Systems (FSEC Standard 104 -10) and was found to meet the minimum standards established by FSEC. North Central South The calculated Florida Energy Factors for this system are: 2.4 2.6 2.6 DESCRIPTION Collector Manufacturer 1. Alternate Energy Technologies 2. Alternate Energy Technologies 3. Solar Hydronics Corp. FSEC Number 00089N 00214N 00332N Model Number AE -32 MSC -32 SHC -32 Units 1 1 1 Tank Manufacturer Capacity (gal) Type: Direct 1. Existing UL listed conventional 66 gallon tank retrofitted for solar application. 2. 3. Pump Manufacturer 1. March 2. Solar Hydronics Corp. 3. Laing Model Number 809 -BR -12/24 SHC -12/24 DC -201 w/IM Power Draw (Watts) Type: DC 48 48 2.9 Controller Manufacturer Model Number Type Photovoltaic 1. Hoxan 2. Solarex 3. AEE 4. BP H -1004 MSX -10 AE -010J SX -310J lO Watt lO Watt 10 Watt 10 Watt Freeze Protection 1. Manual drain down 2. Freeze protection valve 1679 CLEARIAKE Roan. Oxx , FLORIDA 32922-5703 • TEL .321.-63S -1000 • FA%:321 -63 n] UNIVERSITY Srsrein OF Ftc.r+o . • M EcxrAL t?pporrrunrrviAFrusannm?e Ac .cuv &PLOVER • A 1RsrAmai IXSPTu E SU .ucf edu UN. OF CENTRAL FLOv FSEC # S9105 FLORIDA SOLAR ENERGY CENTER Approved Solar Energy System Approval Date: Dec 1991 Revision Date: Jan 2012 1679 CLEARLNKE RoAn, CAXX)A. FLORIDA 32922-5703 • TEL 321-638-1000 • FAX 321-638-1010 • www.fiecmcf edit UNIvEzarY SiSTEM OF ROMA • AN EOUAL OFTORTUNTWAFFMATIVE AtacAl &PLOVER • A RESEARCk1 IN.317rUIE OF THE UNVERSITY OF CENTRAL Ft SunWize OEM Series 40W, v20W and IOW (I to r) SunWize OEM Series Solar Modules SunWize OEM modules deliver top - quality performance for all photovoltaic applications including rural electrification, water pumping, telemetry, communications, and general battery charging. Ideal for AC and DC installations, SunWize OEM modules can be used in single module and multiple - module systems. OEM10 and OEM20 modules have 34 solar cells and the OEM40 has 36 solar cells connected in series providing maximum charging power. The glass surface is impact resistant and allows maximum light transmission. Single crystalline solar cells are encapsulated and bonded to the glass in multiple layers of ethylene vinyl acetate (EVA) and laminated with a white TedlarTm backing insuring long life in severe environmental conditions. Bypass diodes contained within the junction box insure reliable operation. Anodized extruded aluminum frames add strength and durability to the modules. Includes pre - drilled mounting holes. Weather proof junction box has multiple 1/2" knock -outs to accommodate liquid tight fittings and conduit or cable. OEM series modules are ISPRA certified to IEC 61215 standards and are FM approved for Class I, Div. II hazardous locations. OEM series modules carry a 20 -year, 80% power output warranty. PLEASE NOTE: the OEM20A is not ISPRA Certifed and is awaiting FM Approval for Class 1 Div 2. Mote Watts lfrttp Vo Dint' tt5io Weight 103000SW10 136001 103000SW40 OEM10 OEM20A OEM40 10 16.7 0.60 20 16.7 '-1:2O 40 16.7 2.40 19.6 20.0 21.0 0.75 1.35 2.68 15.2 x 14.8 x 1.3 20.9 x 16.9 x 1.3 38.3 x 17.1 x 1.3 4.5 6.5 12.5 OEM Module Physical Specifications OEM 10 A B C D E F 17.69 11.44 10.18 3.93 9.84 4.92 20 17.69 16.94 15.67 3.93 9.84 4.92 40 38.30 17.16 15.90 7.33 23.62 9.84 NOTE: OEM40 has 4 mounting holes on each side of frame. (dimen. F) Shown from left to tight are the SunWize OEM70, OEM20, OEM40 22 ITT Engineered for life Centrifugal Pumps Applications Specifically designed for the following uses: •Hot Water Circulation •Radiant Floor Heating •Liquid Transfer *Solar Applications •General Purpose Pumping Specifications Pump: •Max Capacities: 7 GPM *Max Head. 14.5' *Pipe Connections: 1/2" FPT and 1 /z" Sweat Suction and Discharge '/" Union Connection •Maximum Working Pressure: 150 PSI *Maximum Temperature: 203 F •Rotation: counter clockwise when viewed from the motor end Motor: *Electronically Commutated DC Spherical Motor *Canned Spherical Motor Type •8 -24 Volt DC Automatic Overload Protection *Low In -Rush Current Features Compact Design: Close coupled, space saving design provides easy installation. Mounting: Pump can be mounted horizontally or vertically with motor end down. Laing Thermotech D5 Brass Spec Sheet Construction: Wetted parts are brass, 316SS, thermoplastic, carbon and ceramic for superior corrosion resistance. Ceramic Bearing Ball and Carbon Bearing Cap: High density ceramic bearing ball and graphite impeller bearing cap designed for high efficiency and long life. Impeller: Highly efficient and dynamically balanced with carbon bearing for smooth ultra quiet operation. Casing: Casing is brass construction. Mechanical Seal: Unique patented design has no mechanical seal which is a potential leak path. Motor: Highly efficient and ultra quiet spherical motor design. Pump is designed for continuous operation. All ratings are within working limits of the motor. Electronics: Embedded microprocessor control is self regulating and available with variable speed with PWM input or dial control (potentiometer) on the pump. Noise level: Whisper quiet, less than 40 db. Weight: Lightweight construction weighs less than 21bs. (can use up to 2 collectors) SOLAR THERMAL COLLECTORS) PHOTOVOLTAIC MODULE VACUUM BREAKER AUTOMATIC AIR VENT PRESSURE REUEF VALVI AUTOMATIC FREEZE VALVE ROOF PENETRATION V COPPER TUBING & INSULATION LOW VOLTAGE P.V. WIRES RED + BLACK - P.V. CIRCULATOR PUMP ON /OFF SWITCH MANUAL DRAIN BALL VALVE (ISOLATION VALVE) COLD WATER FROM HOUSE --- RESET BUTTON HEATING ELEMENT THERMOSTAT CONTROL SOLAR FEED TO ! 1 I COLLECTOR I ( I I ;I I tI L; BACK -FLUSH VALVE/ MANUAL DRAIN CHECK VALVE BALL VALVE (ISOLATION VALVE) HOT WATER TO HOUSE ELECTRICAL SUPPLY TEMPERATURE & PRESSURE RELIEF VALVE SOLAR RETURN FROM COLLECTOR SOLAR HOT WATER TANK # DYC1063 Semi -Gloss Acrylic Latex Enamel Paint Product Description #DYC1063 is a semi -gloss acrylic latex enamel U -V enhanced paint and is ideal when used for field coating exterior rubber insulation used in a solar systems' piping. Recommended Use Surface: For use on exterior rubber pipe insulation. Product Advantages Excellent durability Water clean up Elasticity Ease of application Super U -V protection Material Preparation, Mixing: Stir from bottom with vigorous strokes. Do not add oil or other paints. Limitations CAUTION: DO NOT apply to a damp surface. Keep from freezing. Surface Preparation Exterior rubber pipe insulation outer surface must be clean and dry. Application May be applied by brushing, rolling or spraying. When two coats are needed allow first coat to dry 20 minutes before applying finish coat. Limitation of Liability Technical data is true and accurate at date of issuance, but subject to change without notice. This product conforms to paint quality standards, but no other warranty or guarantee is expressed or implied. Liability, if any, is limited to replacement of product or purchase price. Labor, cost of labor, or other consequential damages is hereby excluded. 1423 Gunn Highway Odessa, FL 33556 Technical Data Product #- DYC1063 Generic Type- 100% Acrylic Latex Color- Bronze % Solids by weight- 46.2% % Solids by Volume- 34.5% Recommended Coverage: 6 mils wet 2 mils dry 275 avg. sq. ft. / Gallon % Vehicle solids by Weight- 29.7% % Pigment by Weight- 23.4% % Solvent by Weight - 44.6% Viscosity (Stormer)- 80-85 KU Weight/Gallon- 10.44 lbs Flash Point- None Dry Time- 70 °F., 50% R.H. Touch- 10 minutes Recoat- 20 minutes Reduction- Water Clean Up- Water 813 -403 -5100 BACK HVAC/R Insu4Tube® Co l haul -Tube® 3 FT (Re -slit) haul- Tube® 6-FT (Unlit) haul- Tube® White 6 FT haul - Lock® Seam-Seal 6 FT haul -Loci ® Seam -Seat 3 FT h aul -Lock® White Seam-Seal 3 FT haul- Sheet® Rol w/PSA h aul- Sheet® w lh PSA haul- Sheet® 62S Rol haul- Sheet® MS K Rex Clad® WT K Flex Clad® WTSheet K F ax Clad® WT NS K -Hex Clad®AL K -Fex Clad®AL Sheet K -Rex Duct® Liner Gray K Flex Duct® Lher Gray w/PSA K -Fl® Grooved Tees K Fl® Bastomedc Tees K -Fl® P -Trap K -Fl® 90 Bbow s K Fl® Bastorrertc 45 Elbow s K Fl® Grooved Elbows r Insul -Tube® 6-FT (Unslit) Insui- Tube®8 foot (unslk} Is a black, flexible elastomeric foam tube used to conserve energy and prevent condensation on piping applications. The closed cell properties of Insul -Tube® 8 -foot (unlit) create exceptional thermal and acoustic insulation, protect against moisture penetration and provide the best solution for applications within a - 297 °F to +220 °F temperature range. Insul -Tube® 6-foot (unlit) Is primarily used in the HVAC/R market and comes in 6' lengths in a variety of sizes from 5/8" to 6 -5/8" inside diameter up to 2" wall thickness. It is 25/50- rated, according to ASTM E- 84 standards for surface burning characteristics of building materials, up to 2" wall thickness. Quick Search AI,D5 Insul -Tube® products are non - porous and non -fibrous and resist mold, fungal and bacterial growth. For added protection, all Insul -Tube® products are protected with an antimicrobial agent HVAC/R SPECIFICATIONS All Insui -Tube® products are GREENGUARD®certified under the Children and Schools classification and are approved through supervision byte Factory Mutual Research Corporation. Slaaw Pk'e:},b°144tMt� Made in USA Bo o COPY RIGHT & INTELLECTUAL PROPERTY NOTICE SCOPE OF WORK: INSTALLATION OF A SOLAR WATER HEATING SYSTEM WITH A ROOF TOP COLLECTOR 1 DESIGNED PEI : • ASCE 7 -05 J ' ( WIND LOAD: I WIND EXPOSURE: DESIGNED FOR 160 MPH EXPOSURE CATEGORY C SOLAR HYDRONICS CORP (FORMERLY KNOWN AS SOLAR WORLD) DOMESTIC HOT WATER -(DHW) INSTALLATION NOTES: 10 JULY 09 GENERAL THIS DRAWING AND THE SPECIFICATIONS HEREON ESTABLISH THE MINIMUM REQUIREMENTS FOR DHW EQUIPMENT ON BUILDINGS IN FLORIDA 60 FEET OR LESS IN HEIGHT AND AT ROOF ANGLES FROM FLAT UP TO 45 DEGREES. PER THIS PARTICULAR INSTALLATION DOCUMENT, THE SOLAR HYDRONICS CORP DHW SOLAR PANELS MAY BE INSTALLED PARALLEL TO THE ROOF PLANE WITH HOLD DOWNS FLUSH ON TOP OF THE UPPER SURFACE OF THE ROOF COVERING OR TILTED -UP ID ACHIEVE BETTER SOLAR COLLECTION. PLUSH -MOUNT SHALL REQUIRE 4-ANCHORS. (3/8 -INCH DIAMETER CRS, CORROSION RESISTANT STEEL) IN PZ -1 & PZ -2, EXPOSURES B & C, IN ALL WIND ZONES UP TO AND INCLUDING 160 MPH. 'ANCHORS CAN EITHER 8E, AT CONTRACTORS' CHOICE, 4-ANCHORS FORA SINGLE COLLECTOR OR 4- ANCHORS FOR TWO COLLECTORS THRU USE OF APPROVED RACKING TO TIE THE TWO COLLECTORS TOGETHER -SEE FIGURE 2. TILT -UP IS PERMITTED ONLY WITH THE FOLLOWING STIPULATIONS: A) NO INSTALLATIONS OUTSIDE OF PRESSURE ZONE 1; 8) USE ONLY OEM HARDWARE- EXCEPT 814 TEKS PER 518080 2; C) COLLECTOR LONG AXIS HORIZONTAL AND 30 DEGREES MAXIMUM TILT ANGLE; D) WIND ZONE 140 MPH AND LESS REQUIRE 4- AN0H0115 PER TILT -UP COLLECTOR; F) WIND ZONES GREATER THAN 140 MPH REQUIRE 6 ANCHORS PER TILT -UP COLLECTOR AND MINIMUM TILT POLE WALL THICKNESS OF 1 /8TH -INCH. CONTRACTOR SHALL KEEP LAG BOLT LOADING TO UNDER 528 POUNDS OF UPUFT. REFER TO WIND LOAD CALCULATIONS AT HITPWW W W. CADVICE .US /SW/WINOLOAOCAICU1ATIONS.PDF WHEN LAG LIMIT IS FKCFFDEO CONTRACTOR SHALL USE MORE LAGS, I -BOLTS OR ALL- THREAD ROD. FOUR1 -80LT5 OR ALL- THREAD RODS CAN HANDLE THE LOAD OF 2 -EACH, 40SF SOLAR COLLECTORS IN ALL LOADING CASES ON THE CHART. WHEN STRAYING INTO P22, INCREASE ANCHORS 50 %ON THE PORTION OF THE COLLECTOR IN P22. ABSOLUTELY NO INSTALLATIONS IN P23. TESTING: THE SOLAR HYDRONICS CORP DHW COLLECTORS HAVE PASSED MIAMI TESTING LABS WIND LOAD TESTING OF -102 P5F PER ASTM E -330 (MIL FILE NUMBER 95- 1249).THIS ENGINEER HAS EVALUATED THE INSTALLATION COMPONENTS AND HARDWARE CURRENTLY PROVIDED BY SOLAR HYDRONICS CORP AS OEM INSTALLATION KITS AND FOUND THEM TO MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE CURRENT AS OF THE DATE OF T4S PLAN. THERE SHALL BE NO SUBSTITUTION OF OTHER VENDOR MATERIALS WITHOUT PRIOR APPROVAL OF THIS ENGINEER THRU SOLAR HYDRONICS CORP. HARDWARE THIS ENGINEER HAS DETERMINED THAT THE HOLD -DOWN HARDWARE AND FASTENERS SUPPLIED BY SOLAR HYDRONICS CORP WILL WITHSTAND HURRICANE FORCE WINDS UP TO AND INCLUDING 160 MPH 3- SECOND GUSTS THE ONLY REMAINING VARIABLE OF SIGNIFICANCE S THE ATTACHMENT OF THE HOLD DOWNS TO THE UNDERLYING ROOF SYSTEM USING OEM HARDWARE. LAGGING OF SHE DHW COLLECTORS FOR FLUSH MOUNT INSTALLATION (PARALLEL WITH THE ROOF SURFACE AND AS CLOSE THERETO AS PERMITTED BY OEM HARDWARE) SHALL BE ALLOWED IN EXPOSURE CATEGORY B AND C AND IN BOTH P21 AND PZ2 AT MEAN ROOF HEIGHTS OF 60.55 OR LESS AND IN ALL WINO ZONES THRU 160 MPH SO LONG AS THE FOLLOWING CAUTIONARY RULES ARE OBSERVED. LAGS SHALL BE CORROSION RESISTANT STEEL, 3/8 INCH DIAMETER MINIMUM OR BETTER LAGS SHALL ACHIEVE AT LEAST 3- INCHES OF THREAD EMBEDMENT IN RAFTER OR BLOCKING. MEASUREMENTS MUST BE CAREFULLY MADE AND PILOT HOLES SHALL BE DRILLED TO ENSURE HITTING UNDERLYING RAFTERS OR TRUSSES AND TO AVOID WOOD SPLITTING. SPECIAL PROCEDURES TO USE WHEN, IN THE INSTALLERS OPINION, HITTING THE CENTER OF TRUSS OR RAFTER WITH A LAG CANNOT BE ASSURED. EITHER USE A 3/8 INCH (MIN) '8* BOLT GRABBING THE TRUSS /RAFTER OR 3/8 INCH DIAMETER (MIN) ALL THREAD ROD PLUS STANDARD FENDER & IOC( WASHERS AND NUT THRU MINIMUM 4' BY 4° BY9° BLOCKING ON THE UNDERSIDE OF THE ROOF SHEETING. WHERE BLOCKING METHOD 15 USED, INSTALLER SHALL APPLY A GENEROUS BEAD OF CONSTRUE-110N ADHESIVE FOR MINIMUM OF 1 FT ALONG THE NEAR JOINTS OF THE ROOF TRUSS AND SHEETING ON EACH TRUSS ON 80TH SIDES OF THE BLOCKING -SEE FIGURE 2 ON THIS SHEET. PLUMBING SHALL BE PER FIGURE 1. FLORIDA PLUMBING CODE SHALL BE ADHERED TO. PARTICULAR ATTENTION SHALL BE GIVEN TO PROTECTION AGAINST OVER- PRESSURE AND FREEZING- PER FLORIDA MECHANICAL CODE, CHAPTER 14, AND PER 501AR HYDRONICS CORP INSTALLATION INSTRUCTIONS THIS DRAWING SHOWS THE'D. VERSION PLUMBING. HOWEVER, THERE ARE OTHER VARIANTS (PHOTO - VOLTAIC PUMP, INDIRECT, AND /OR DRAIN -BAC() WHICH, ALTHOUGH NOT SPECIFICALLY SHOWN HEREON, ARE COVERED BY THIS SEALED DRAWING -SO LONG AS INSTALLED PER SOLAR HYDRONI05 CORP INSTALLATION INSTRUCTIONS. WATERPROOFING INSTALLER SHALL ADHERE TO REQUIREMENTS OF FBC CHAPTER 15 (ROOFING) AND BEST PRACTICES OF THE NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE THAT THE SOWR INSTALLATION DOES NOT CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM 'AGES'. QUESTIONS: INSTALLERS, AUTHORITIES HAVING JURISDICTION, OR OTHERS HARING QUESTIONS OR DIFFERING CONDITIONS, MAY CONTACT NOTICE TO AHJ, CONTRACTOR, WNER & OTHER I6TENTEREESSTED PAARIIIEES)O Ni@TLANOVIDE56M THIS ENGINEER - SEALED DETARS & SPECIFICATIONS FOR INSTALLATION OF BOTH AE & MORNING STAR CORPORATION (MSC) SOLAR DOMESTIC HOT WATER SYSTEMS. AE & MSC ARE MADE IN THE SAME PLANT BY THE SAME MANUFACTURER. WHILE THERE ARE SLIGHT PHYSICAL DIFFERENCES, THESE SYSTEMS ARE EQUIVALENT STRUCTURALLY, HYDRAULICALLY, & THERMALLY. AE DETAILS ARE SHOWN ON THIS PLAN SHEET, BECAUSE AE S THE VOLUME LEADER MSC DETAILS MAYBE VIEWED AT; hop: //wwwaelsolarmm/ 11 ALL AFFIDAVITS DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GF7FI MAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C -700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC 6700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC 6700 MAY BE VIEWED AT: HTTPI/ GEZEIMANPECOMJREFERENCE /AGf6700.PDF DIRECTED- SYSTEM THIS DRAWING SHOWS THE SOLAR HYDRONICS CORPORATION DHW '5' (DIRECT) SYSTEM AND THIS PARTICULAR SYSTEMS PLUMBING. THERE ARE OTHER, SLIGHTLY DIFFERENT, SOIAR HYDRONICS CORPORATION 01-EW SYSTEM VARIANTS WHICH ARE ALSO COVERED BY THIS SEALED DRAWING. THIS 5 BECAUSE THE CRITICAL ELEMENT-THE COLLECTOR(S) AND ROOF MOUNTING DETAILS REMAIN THE SAME WHETHER THE SOLAR HYDRONICS CORP.DHW SYSTEM BEING INSTALLED ISA DIRECT, IN-DIRER OR DRAIN -BACK MODELS WHICH CAN BE CONRGURED WITH EDHER AN A/C OR PHOTO - VOLTAIC PUMP OR O /CCOMROUED ELECTRIC PUMP COLLECTOR SENSOR SOLAR LOOP DRAI MOTORIZED BALL VALVE SOLAR LOOP DRAIN ISOLATION VALVE EXPANSION TANK DIFFERENTIA. CONTROL HOT WATER OUTLET ,o..n...:.... -...., I COLD WATER INLET SHUT OFF VALVE BACKUP ELECTRIC ELEMENT DIP TUBE STORAGE TAN TANK SENSO' '.i•'::::.,� 3 - +r J TANK DRAIN ®FIGURE 1 01 LEDGEND re ISOLATION VALVE (OPTIONAL.). DTI TANK SUPPLY SMUT OFF lAsT< SOLAR LOOP DMN (CPTIONAU 'RI 193EHE PROTECTION VALVE (OPTIONAL) TEWERATURE/PFESSURE FE3.ff VALVE PRESSURE RELJEF VALVE 0 AA YEW (OPTIONAL) S ... MOTORIZED BALL VALVE 0 ELECTRIC PM AC/DC U EWAMBON TAMK (OPTIONAL) SOLAR SYSTEM COLLECTOR: MODEL AE-21/46-2444626/AE-28/AE-32/AE-40/ AE- 21 l46- 24/A6/AE- 28/AE- 321AE-402 MSC21 / MSC -32 / MSC40/SHC- 21 /SHC- 32/SHC-40 IAPPLICABLE CODE: FLORIDA 2007 CODE W/09 SUPP (THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS. EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN. NOTE: SUITABLE FOR HVHZ SEE CALCULATIONS: HTTP:/ IGEZELMANPE .COM/ST_INSTALLATION.HTML REGARDING WIND LOAD - MY DESIGNS CLEARLY SHOW COMPLIANCE PER ASCE 7 WITH THE FLORIDA BUILDING CODE. REGARDING GRAVITY LOAD - OUR HEAVIEST COLLECTOR WEIGHS 165 POUNDS WHICH IS DISTRIBUTED OVER A40 S.F AREA WATER IN THE COLLECTOR IS NEGLIGIBLE. EACH COLLECTOR HOLDS ABOUT A GALLON OF WATER. POOL COLLECTORS A BIT MORE, HOT WATER COLLECTORS A UTTLE LESS. REGARDLESS, SOLAR PANELS ARE AN INSIGNIFICANT LOAD ON THE ROOF UNDERNEATH! GENRAL NOTE: ALL HOT WATER SOLAR COLLECTORS SOLD IN 514IS STATE ARE REQUIRED TO HAVE BEEN TESTED BY THE FLORIDA SOLAR ENERGY CENTER AND BEAR ITS CERTIFICATION LABEL THE COLLECTORS LISTED ON THIS PLAN COMPLY WITH THOSE REQUIREMENTS: FURTHER INFORMATION MAY BE ACCESSED ON LINE AT: HTTP : / /WWW.FSEC.UCF.EDUJEN/INDUSIRY )TESTING /STCOLLECTORS/HOT WATER_RATINGSJINDEX.HTM ROOF PENETRATION AND FT.BIINO. NOTE, COLLECTORS MAY BE 0800864 VERTICALLY OR HORIZONTALLY MOUNTING BRACKET (E DETAL BH.OW) MOLJNB CAN 00 ON SIDES OR COLLECTOR ENDS OF COLLECTOR....' COLLECTOR P22 ROOF TRUSS TER lug 111111 111 FRONT ELEVATION SCALE: 1St CO' PZ = PRESSURE ZONE WZ = WIND ZONE OOLLEC 443UTLET ROW PgNEYNAMN lN1DftAtmo660 SECTION A IDSPAN REINFORCEMENT . lr _ TWO COLLECTORS MAY BE MOUNTED ON 2- PIECES OF APPROVED RACKING W/ AE -RM CUP HELD DOWN BY 4 ANCHORS EXISTING ROOF TRUSS. TOP P CHORD u� PL SFIW COLLECTOR MOUNTING BRACKET APPROVED RACKING SYSTEM W/ CHANNEL NUT 1 DIA. SPACER W/ WATERPROOF SEALANT OEM HOLD DOWN: LAGGING 1 POSITION OYERTRUSS', 3/8" LAG BOLT OR J- BOLT (HOOKS TRUSS) I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE REQUIREMENTS OFTHE CURRENT FLORIDA BUILDING CODE TYP. SHINGLE, MET, FLAT TILE DETAIL. SCALE: 1.112..1, PTA. SPACER, LENGTH ADJUST FLUSH WI TOP OFTIE EXISTING MEMBRANE ROOF INSTALLATION DIAGRAM 1 MOUNTING BRACKET ALUM TUBE ALUM TUBE PITCH PAN ALL THREAD ROD , J BOLT OR LAG TILE ROOF: CUT OUT RECTANGLE FOR PITCH PAN, INSTALL AND FILL W/ 1 -PART POURABLE WATER PROOF CONSTRUCTION SEALANT ALTERNATE. TILE ROOF MOUNTING DETAIL FILL W/ T -PART POURABLE WATERPROOF CONSTRUCTION SEALANT ALUM TUBE PITCH PAN ALL THREAD ROD , J BOLT OR LAG SCALE ...Sr T oz FIGURE 2 8CALEVALLE3 EXPLANATORY INFORMATION ENLARGED VIEWING & HYPERUNKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HVPERUNK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION. EV MAY BE ACCESSED AT HTTPJ /WWW.CADVICEUS /SW /AS.13.WH.PDF THERE ARE THREE PROPRIETARY RAC( SYSTEMS APPROVED FOR USE WITH THIS PLAN. THESE MAY BE USED TO SUPPLEMENT OR TO REPLACE THE DETAILS SHOWN IN FIGURE 2. IN ALL CASES REFER TO OEM INSTRUCTIONS FOR DETAILS/SYSTEM BEING USED. IN THE EVENT OF A CONFLICT BETWEEN OEM INSTRUCTIONS AND THIS PLAN, OEM INSTRUCTIONS SHALL PREVAIL OEM MANUALS MAY BE ACI'FSSFD ELECTRONICALLY USING THE FOLLOWING HYPERUNKS: HTTP: //W W W.UNISIRUF.COM/ LITERATURE /INDEX.PHP700C =N014&PG =1 HTIP. //WWW.IRONRIOGE.COM/ FILES /SRS /IRONRIDGE XRS-2 HAIL S1SIEM.PDF HTTPJ/W W W.UNIRACCOM/PDF/II227.PDF STRUCTURAL LOADING: THIS PLAN WAS ENGINEERED FOR THE ENTIRE STATE OF FLORIDA INCLUDING HVHL THE SOLAR EQUIPMENT REPRESENTED ON THIS PLAN IMPOSES A POSITIVE LOAD UPON THE ROOF STRUCTURE OF LESS THAN 4455. MY UPUFT PRESSURE CALCULATIONS MAY BE VIEWED AT HTTP //W W W. CADVICE .US/SW/WINDLOADCALCULATIOFS.POF THE UPUFT PRESSURES FOR 160MPH, EXPOSURE CATEGORY C, BUILDING IMPORTANCE FACTOR CATEGORY II, HEIGHT 60-FT OR LESS, SLOPE 45 DEGREES OR LESS ARE: P21,56.6 P5F; PZ2_ 106.6 P5F; 523_ 153.2 PSF. QUESTIONS REGARDING ROOF PRESSURE ZONES ARE REFERRED TO THE ASCE 7 DIAGRAM FOUND ON PAGE 5 AT THE ABOVE UNIRAC HYPERUNK. ®FIGURE 3 03 ai F. Nrs WHERE APPLICABLE FILL CAVITY UNDER TILE W/ EXPANSION CONST. FOAM EXISTING ROOF TRUSS, TOP CHORD TYP. BARREL TILE ROOF MOUNTING DETAIL ,,4,5.1.,2.,•, CONSTR. s ADHESIVE MEDIUM BEAD BOTH SIDES OF INTERFACE BETWEEN ROOF SHEETING AND TRUSS 1 FOOT IN EACH DIRECTION STARTING FROM 'SPANNER' TO WHICH COLLECTOR MOUNT FOOT -PAD IS SECURED BY ALL- THREAD ROD. EXISTING ROOF NOTE -THERE SHALL BE AT LEA TYP. MOUNTING DET Ra k Mount SHW COLLECTOR MOUNTING BRACKET EM HOLD DOWN: LAGGING ( POSITION OVER TRUSS) J- BOLT (HOOKS TRUSS) BLOCKING (BETWEEN TRUSSES) SEALANT FOR WATERPROOFING APPROVED RACKING SYSTEM WI CHANNEL NUT 1' DIA SPACER, LENGTH ADJUST FLUSH W) TOP OF TILE • DIA SPACER W/ WATERPROOF SEALANT EXIST. BARREL TILE OEM HOLD DOWN: LAGGING ( POSITION OVER 'MUSE 3+8' LAG BOLT OR J- BOLT (HOOKS TRUSS) 4x4 BETWEEN TRUSSES IN CONTACT W/ PLYWOOD TYP. BEAD OF CONSTR. EXISTING ROOF TRUSS, TOP CHORD LID-DOWN ATTACHMENTS FOR EACH SOLAR COLLECTOR ON A ROOF. RUFit taunt $SrT1 MOUNTING BRACKETS SCALE Nia. HINGE MOUNT CUP 3/8' -18 FINISHED HEX NUT 1'x1'%0.072' ALUMINUM SQUARE TUBE TILT KIT - DECK ANCHOR SCALE: CUTS OEM FURNISHED FASTENER 1/4° -20 X 112' HEX CAP SCREW 3/8'-16 X4'HEX CAP SCREW 318'-1(3 X 1 -3/4' HEX CAP SCREW TRIANGULAR MOUNTING BRACKET ®FIGURE 2 az cAdvice.us <Advice Inc 3603 Rene(54 Dr T PH. 813 919 9154 FX 866 694 7251 818111801(488(8488 1/ www.C6dv¢e.*8 SYSTEM: SIC! Solar HydroNC6 Corp. 1423 GUNN HIGHWAY ODESSA, FL 33556 REV.083108 -TM PUBLISHED:828201171722 AM THIS IS A SINGLE SHEET PLAN SHEET NAME: PERMIT SET DRAWN:SB CHECKED:AG SHEET NO: A.1.3