Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
M-11-8501
Department of Environmental Resources Management Miami -Dade County Plan Review Summary Process Number: M2011008501 FINAL CORE REVIEW DATE: 8/10/2011 OVERALL STATUS: Overall Disapproval PROJECT DETAILS: CONTACT DETAILS: FOLIO: 11- 3206 - 013 -3900 NAME: MARK CAMPBELL ADDRESS: 9531 NE 2 AVE, , FL EMAIL: PERMIT TYPE DESC.: PARTIAL DEMO PHONE #: 3057542318 DISAPPROVAL CODES: Disapproval Code 01: 0294 - Requires Air Section approval for Asbestos. Contact the West Dade office at 11805 Coral Way TASK REVIEWED BY STATUS DATE STATUS Initial Core Review Miriam Negrin 08/10/2011 Reviewed Comments: PROPERTY INCLUDEDS THE FALLOWING FOLIOS# 1132060133890/1132060133900 /910 &920.4A COV UNDER: DVS, LLC (CFN #2011R0384320 .THIS IS A REVISION TO M2011006537 TO ADD INTERIOR DEMO SQ FT. ASBES Review Agustin Socarras 08/10/2011 Disapproved Comments: 8/10/2011: Project includes the partial demolition of an attached structure and parts of the roffing and exterior walls. Pursuant to the Code of Federal Regulations (CFR) 40 CFR 61, subpart M, section 145(a) National Emission Standards for Hazardous Air Pollutants (NESHAP), total or partial demolition requires the following: 1. Asbestos survey report of all areas to be impacted by demolition work. 2. Notice of Demolition completed in full, (form attached). 3. A separate check payable to Miami -Dade County ($225.00 if total affected surface is Tess or equal to 5000 SQFT or $400.00 is larger than 5000 SQFT). For additional help, contact an asbestos reviewer at (786) 315 -2813 or via e-mail at socara @miamidade.gov. To coordinate a meeting with an asbestos reviewer call 786- 315 -2844, meetings are held Monday -Friday between 8.00AM to 12.00PM. For more information on asbestos, go to the following link at: http:// www. miamidade. gov /DERM /pollution_asbestos.asp. Final Core Review PLAN CONDITIONS: NO CONDITIONS Miriam Negrin 08/10/2011 Overall Disapproval PLAN REVIEW FEES (FEES ARE SUBJECT TO CHANGE PENDING FINAL APPROVAL): FEE CODE DESCRIPTION USER DATE UNIT TOTAL Total FOR MORE INFORMATION PLEASE CONTACT: YOUR DERM CORE REVIEWER: hadadm @miamidade.gov DERM PERMITTING AND INPECTION CENTER, 11805 SW 26 ST, 786- 315 -2800 DERM OVERTOWN TRANSIT CENTER, 701 NW 1 CT, 305 - 372 -6899 Coastal: EQCB: dermcr @miamidade.gov egcb @miamidade.gov Specialty Engineering Reviews (industrial, storage tanks, industrial waste pretreatment, asbestos, paving & drainage, trees): dermengreviews @miamidade.gov Tree Permit applications: dermtreeprogram @miamidade.gov Water Control: dermwatercontrol @ miamidade.gov Wetlands: dermwetlands @miamidade.gov /1 I tS EIWIRONMENTA L, INC. Asbestos Business License #ZA- 0000164 Environmental` CoristPlting Services Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations October 12, 2010 Client: Bennett Electric Jack Higgins 10007 NE 4 Avenue Miami Shores, FL 33138 ARS- Report- 2010 -0805- Asbestos Job Site: Commercial Building 9501, 9519, 9523,9531 9531, 9537, 9541 & 9545 N.E. 2nd Ave 209 N.E. 95 Street Miami Shores, Florida ASBESTOS BUILDING SURVEY Pursuant to your request; ARS Environmental, Inc., has performed an Asbestos Building Survey on 10 -07 -2010, and limited to the above referenced location. The interior and exterior of the structure was visually inspected to identify building materials that may contain asbestos. Suspect materials were collected and samples sent to laboratory for analysis. Roofing materials were sampled. If the roof system will be disturbed by renovation or demolition samples of the materials that will be affected should be obtained and analyzed to determine asbestos content prior to any disturbance. Based on the laboratory analysis Asbestos was detected greater than 1% in some of the secured bulk samples. See Appendix B for a list of materials that detected asbestos content. Our recommendations for the materials found to be Asbestos Containing can be found in Appendix C. There is important information in these sections that is not included in this executive summary. This report should be read in its entirety, including detailed information that is contained in other sections and appendices of this report. Appendix A: Appendix B: Appendix C: Appendix D: Appendix E: Appendix F: TABLE OF CONTENTS Bulk Sample Itemization Sheet 3 Asbestos Containing Building Material Damage and Hazard Assessment 9 Recommendations • 11 Chain of Custody & Laboratory Analytical Results 15 Inspectors Certificate & Company License 27 General Terms & Conditions 30 Page 1 of 32 Mailing Address: 10097 Cleary Boulevard • #305 • Plantation, Florida 33324 Phone: (954) 227 -2402 • Fax: 866- 748 -1264 URL: wvwv.arsenvironmental.com • Email: sales @arsenvironmental.com ARS EN('IIWNMENTAL, INC. Asbestos Business License #ZA- 0000164 Environmental Corisdlting Services Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations October 12, 2010 Client: Bennett Electric Jack Higgins 10007 NE 4 Avenue Miami Shores, FL 33138 ARS- Report- 2010- 0805- Asbestos 'Job Site: Commercial Building 9501, 9519, 9523,9531 9531, 9537, 9541 & 9545 N.E. 2nd Ave 209 N.E. 95 Street Miami Shores, Florida I hereby certify that the above referenced asbestos survey was conducted on 10 -07 -2010, and performed by Alex Front an E.P.A. Accredited A.H.E.R.A. Inspector utilizing the code of the Federal Regulation Standards, 40 C.F.R., Part 763, Subpart E, Section 763. 80- 763.99 and the State Asbestos Regulations, Florida Statutes 469.003. imothy Haughey, !!'.H. Florida Licensed Consultant Cert #IA0000016 Page 2 of 32 Al - 'r• t, Certified Asbestos Surveyor ARS Environmental, Inc. Certificate #:128740 Mailing Address: 10097 Cleary Boulevard • #305 • Plantation, Florida 33324 Phone: (954) 227 -2402 • Fax: 866 - 748 -1264 URL: www.arsenvironmental.com • Email: sales @arsenvironmental.com A RS ENVIRONMENTAL, !NC Asbestos Business License #ZA- 0000164 2010 -0805- Asbestos November 01, 2010 Appendix A Bulk Sample Itemization Sheet Page 3 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations I4 RS ENUI WNMENTAL, INC Asbestos Business License #ZA- 0000164 Project #: November 01, 2010 2010 -0805 BULK SAMPLE ITEMIZATION SHEET (HA) Areas Sample Id Material Class Sample Description Sample Location Estimated Quantity Sample Condition Physical Damage Water Damage Material Contact Sample Friability HA -100 1 S Wall &Ceiling Plaster Composite Sample 9501 -9545 7800 S.F. Good No No High NF HA -100 2 g Wall &Ceiling Plaster Composite Sample 9501 -9545 Included Above Good No No High NF HA -100 3 S Wall & Ceiling Plaster Composite Sample 9501 -9545 Included Above Good No No High NF HA -100 4 S Wall & Ceiling Plaster Composite Sample 9501 -9545 Included Above Good No No High NF HA -100 5 S Wall & Ceiling Plaster Composite Sample 9501 -9545 Included Above Good No No High NF HA -100 6 S Wall &Ceiling Plaster Composite Sample 9501 & 9519 Included Above Good No No High NF HA -101 7 M Grey Blow -in Insulation 9501 & 9519 4800 S.F. Good No No Low F HA -101 8 M Grey Blow -in Insulation 9501 & 9519 Included Above Good No No Low F HA -101 9 M Grey Blow -in Insulation 9501 & 9519 Included Above Good No No Low F HA -101 10 M Grey Blow -in Insulation 9501 & 9519 Included Above Good No No Low F Checked Below are Non - Typical Suspect Material that were observed during inspection (No Samples Were Obtained) UNo Insulation Behind Wallboard Ceramic Tiles UExterior Wood Soffit UWood Roof Trusses UTerrazzo Flooring UWood Flooring UT-111 Insulation Rubber ❑ Pipe Lagging UMarble Tile UFiberglass Ceiling Tiles Rubber Flooring ❑Front Entrance Metal Doors ❑Carpeting OA/C Fiberglass Insulation UNC Wall Units UNC Wall Units ❑Metal NC Duct ❑Fiberglass Ins above Ceiling Foam Glass Pipe Insulation ❑PVC Piping Note: All Quantities are 'approximations and actual square footage should be verified prior to any disturbance. TBD =To Be Determinbd ' Homogeneous Area: area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. S= Surfacing Materials T= Thermal System Insulation (TSI) M= Miscellaneous Materials F= Friable: Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry. NF= Non - Friable that, when dry, may not be crumbled, pulverized, or reduced to powder by hand pressure. Page 4 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL" INC Asbestos Business License #ZA- 0000164 Project #: November 01, 2010 2010 -0805 BULK SAMPLE ITEMIZATION SHEET (HA) Areas Sample Id Material Class Sample Description Sample Location Estimated Quantity Sample Condition Physical Damage Water Damage Material Contact Sample Friability HA -102 11 M 12" x 12" glacier design ceiling tiles 9501 5000 S.F. Good No No Low F HA -102 12 M 12° x 12" glacier design ceiling tiles 9501 Included Above Good No No Low F HA -102 13 M 12° x 12" glacier design ceiling tiles 9501 Included Above Good No No Low F HA -103 14 M 12" x 12° silted hidden spline ceiling tiles 9501 5000 S.F. Good No No Low F HA -103 15 M 12" x 12" slued hidden spline ceiling tiles 9501 Included Above Good No No Low F HA -103 16 M 12" x 12" sl'�ted hidden spline ceiling tiles 9501 Included Above Good No No Low F HA -104 17 M Black NC duct seam mastic 9519 600 LF. Good No No High NF HA -104 18 M Black A/C duct seam mastic 9519 Included Above Good No No High NF HA -105 19 M Brown Mastic on ceiling 9519 450 L.F. Good No No High NF HA -105 20 M Brown Mastic on ceiling 9519 Included Above Good No No High NF Checked Below are Non - Typical Suspect Material that were observed during inspection (No Samples Were Obtained) OW Insulation Behind Wallboard UCeramic Tiles ❑Rubber Flooring DA/C Wall Units ❑Exterior Wood Soffit UWood Roof Trusses DFront Entrance Metal Doors ❑Metal NC Duct UTerrazzo Flooring UWood Flooring Carpeting ❑Fiberglass Ins above Ceiling UT-111 Insulation URubber Pipe Lagging UNC Fiberglass Insulation °Foam Glass Pipe Insulation UMarble Tile °Fiberglass Ceiling Tiles UNC Wall Units °PVC Piping Note: All Quantities are approximations and actual square footage should be verified prior to any disturbance. TBD =To Be Determined Homogeneous Area: area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. S= Surfacing Materials T= Thermal System Insulation (TSI) M= Miscellaneous Materials F= Friable: Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry. NF= Non - Friable that, when dry, may not be crumbled, pulverized, or reduced to powder by hand pressure. Page 5 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL, INC Asbestos Business License #ZA- 0000164 Project #: November 01, 2010 2010 -0805 BULK SAMPLE ITEMIZATION SHEET (HA) Areas Sample Id Material Class Sample Description Sample Location Estimated Quantity Sample Condition Physical Damage Water Damage Material Contact Sample Friability HA -106 21 M 9" x 9" grey floor tile & mastic under carpeting & 9523 1000 S.F. Good No No High NF Parkway Flooring Rear Area HA -106 22 M 9" x 9° grey floor tile & mastic under carpeting 9523 RearArea Included Above Good No No High NF HA -106 23 M 9° x 9° grey floor tile & mastic under carpeting 9523 RearArea Included Above Good No No High NF HA -107 24 M Yellow vinyl floor sheeting Bathroom 30 S.F. Good No No High NF HA -107 25 M Yellow vinyl floor sheeting 23 BathroomI Above Good No No High NF HA -108 26 M 2' x 2' wormlike design ceiling tiles 9523 1000 S.F. Good No No Moderate F HA -108 27 M 2' x 2' wormlike design ceiling tiles 9523 Included Above Good No No Moderate F HA -108 28 M 2' x 2' wormlike design ceiling tiles 9523 Included Above Good No No Moderate F HA -108 29 M 2' x 2' wormlike design ceiling tiles 9531 4000 S.F. Good No No Moderate F HA -108 30 M 2' x 2' wormlike design ceiling tiles 9531 Included Above Good No No Moderate F Checked Below are Non - Typical Suspect Material that were observed during inspection (No Samples Were Obtained) UNo Insulation Behind Wallboard Ceramic Tiles ❑Rubber Flooring UA/C Wall Units ❑Exterior Wood Soffit ❑Wood Roof Trusses UFront Entrance Metal Doors ❑Metal NC Duct ❑Terrazzo Flooring ❑Wood Flooring Carpeting ❑Fiberglass Ins above Ceiling DT-111 Insulation ❑Rubber Pipe Lagging DAIC Fiberglass Insulation ❑Foam Glass Pipe Insulation ❑Marble Tile ❑Fiberglass Ceiling Tiles URIC Wall Units ❑PVC Piping Note: All Quantities are approximations and actual square footage should be verified prior to any disturbance. TBD =To Be Determined Homogeneous Area: area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. S= Surfacing Materials T= Thermal System Insulation (TSI) M= Miscellaneous Materials F= Friable: Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry. NF= Non - Friable that, when dry, may not be crumbled, pulverized, or reduced to powder by hand pressure. Page 6 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations A RS avoRoNMENTAL, hvc Asbestos Business License #ZA -0000164 Project #: November 01, 2010 2010 -0805 BULK SAMPLE ITEMIZATION SHEET (HA) Areas Sample Id Material Class Sample Description Sample Location Estimated Quantity Sample Condition Physical Damage Water Damage Material Contact Sample Friability HA -109 31 M 12" x 12" cream with streaks floor the & mastic 9531 5000 S.F. Good No No High NF HA -109 32 M 12" x 12° cream with streaks floor tile & mastic 9531 Included Above Good No No High NF HA -109 33 M 12" x 12" cream with streaks floor tile & mastic 9531 Included Above Good No No High NF HA -110 34 M Black floor mastic under ceramic tile 9537 900 S.F. Good No No Low NF HA -110 35 M Black floor mastic under ceramic tile 9537 Included Above Good No No Low NF HA -111 36 M 2' x 2' pinhole design tiles 9541 Hal way 32 S.F. Good No No High F HA -111 37 M 2' x 2' pinhole design tiles 9541 Hallway I Above Good No No High F HA -112 38 M Wallboard/Joint Compound 9545 1000 S.F. Good No No High NF HA -112 39 M Wallboard/Joint Compound 9545 Included Above Good No No High NF HA -112 40 M Wallboard /Joint Compound 9545 Included Above Good No No High NF Checked Below are Non - Typical Suspect Material that were observed during inspection (No Samples Were Obtained) DNo Insulation Behind Wallboard UCeramic Tiles URubber Flooring DA/C Wall Units ❑Exterior Wood Soffit Wood Roof Trusses ❑Front Entrance Metal Doors ❑Metal NC Duct ❑Terrazzo Flooring ❑Wood Flooring ❑Carpeting ❑Fiberglass Ins above Ceiling UT-111 Insulation Rubber ❑ Pipe Lagging DA/C Fiberglass Insulation Foam Glass Pipe Insulation ❑Marble Tile ❑Fiberglass Ceiling Tiles DA/C Wall Units ❑PVC Piping • Note: All Quantities are approximations and actual square footage should be verified prior to any disturbance. TBD =To Be Determined Homogeneous Area: area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. S= Surfacing Materials T= Thermal System Insulation (TS!) M= Miscellaneous Materials F= Friable: Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry. NF= Non - Friable that, when dry, may not be crumbled, pulverized, or reduced to powder by hand pressure. Page 7 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL" INC Asbestos Business License #ZA- 0000164 Project #: November 01, 2010 2010 -0805 BULK SAMPLE ITEMIZATION SHEET (HA) Areas Sample Id Material Class Sample Description Sample Location Estimated Quantity Sample Condition Physical Damage Water Damage Material Contact Sample Friability HA -112 41 M Wallboard/Joint Compound 209 N.E. 95 Street Units 1-4 5000 S.F. Good No No High NF HA -112 42 M Wallboard/Joint Compound 209 N.E. 95 Street Units 1-4 Included Above Good No No High NF HA -112 43 M Wallboard/Joint Compound 209 N.E. 95 Street Units 1-4 Included Above Good No No High NF HA -113 44 M 2' x 4' pinhole design ceiling tiles 209 N.E. 95 Street Throughout Building 900 S.F. Good No No Moderate F HA -113 45 M 2' x 4' pinhole design ceiling tiles 209 N.E. 95 Street Throughout Building Included Above Good No No Moderate F HA -113 46 M 7 x 4' pinhole design ceiling tiles 209 N.E. g5 Street Throughout Building 32 S.F. Good No No Moderate F HA -114 47 M Exterior Brick 209 N.E. 95 Street S.E. Side of Building Included Above Good No No High NF HA -114 48 M Exterior Brick 209 N.E. 95 Street S.E. Side of Building 1000 S.F. Good No No High NF HA -115 49 M Interior/Exterior Concrete 209 N.E. 95 Street Throughout Building Included Above Good No No High NF HA -115 50 M Interior/Exterior Concrete 209 N.E. 95 Street Throughout Building Included Above Good No No High NF Checked Below are Non - Typical Suspect Material that were observed during inspection (No Samples Were Obtained) UNo Insulation Behind Wallboard ✓Ceramic Tiles DRubber Flooring IJA/C Wail Units Exterior Wood Soffit Wood Roof Trusses Front Entrance Metal Doors ✓Metal A/C Duct UTerrazzo Flooring ✓Wood Flooring ✓Carpeting Fiberglass Ins above Ceiling UT-111 Insulation Rubber ✓ Pipe Lagging ZINC Fiberglass Insulation ❑Foam Glass Pipe Insulation Marble Tile UFiberglass Ceiling Tiles ZINC Wall Units ❑PVC Piping Note: All Quantities are approximations and actual square footage should be verified prior to any disturbance. TBD =To Be Determined ' Homogeneous Area: area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. S= Surfacing Materials T= Thermal System Insulation (TSI) M= Miscellaneous Materials F= Friable: Material that may be crumbled, pulverized, or reduced to powder by hand pressure when dry. NF= Non - Friable that, when dry, may not be crumbled, pulverized, or reduced to powder by hand pressure. Page 8 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL INC November 01, 2010 Asbestos Business License #ZA- 0000164 2010 -0805- Asbestos Appendix B Asbestos Containing Building Material Damage and Hazard Assessment Page 9 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL, INc Asbestos Business License #ZA- 0000164 November 01, 2010 2010- 0805 - Asbestos Asbestos Containing Building Material Damage and Hazard Assessment Homogeneous Areas (HA) Sample Id Material Class Sample Description Sample Location Estimatd Quantity Hazard Rank Damage Assessment N.E.S.H.A.P. Category Physical Assessment Sample Friability HA -104 17 M Black NC duct seam mastic 9519 600 L.F. 7 Low CAT I X NF HA -106 21 M 9" x 9° grey floor tile & mastic under carpeting & 9523 Rear Area 1000 S.F. 7 Low CAT I X NF HA -107 24 M Yellow vinyl floor sheeting 9523 Bathroom 30 S.F. 7 Low CAT I X NF HOMOGENEOUS AREA: FRIABILITY An area of surfacing material, thermal system insulation material, F= Friable: Material that may be crumbled, pulverized, or or miscellaneous material that is uniform in color and texture. reduced to powder by hand pressure when dry. MATERIAL QUANTITY NF= Non - Friable: Material that, when dry, may not be crumbled, pulverized, or reduced to powder by hand TBD =To Be Determined pressure. HAZARD RANKING MATERIAL CLASS 1 The highest ranking is reserved for ACM that is "significantly S= Surfacing Materials damaged." T= Thermal System Insulation 2-4 Hazard ranking 2 - 4 reflect ACM that is "damaged" M= Miscellaneous Material 2 indicating "potential for significant damage," 3 indicating a "potential for moderate damage." N.E.S.H.A.P. CATEGORY 4 indicating a "potential for damage." 5-7 Hazard ranking of 5 to 7 are reserved for materials currently Cat I= Category I Non - Friable in good condition, but with a range of moderate to low in the Cat II= Category II Non - Friable likelihood for future disturbance. Fri= Friable DAMAGE ASSESSMENT PHYSICAL ASSESSMENT CODE High Risk: The material is in need of immediate removal or 1. Damaged or significantly damaged (TS!) repair and represents both a health hazard and 2. Damaged friable surfacing regulatory non - compliance. 3. Significantly damaged friable surfacing Moderate Risk: The material may be damaged or accessible, 4. Damaged or significantly damaged friable miscellaneous but does not require immediate response due to 5. ACBM with potential for damage access or potential damage. Minor repairs may be 6. ACBM with potential for significant damage necessary. Manage and monitor the material until 7. Friable ACBM or friable suspected ACBM periodic maintenance or renovation /demolition. Low Risk: The material does not represent a health hazard X. Not Applicable (material is non - friable surfacing or miscellaneous) and can be managed in place until demolition/ renovation. Page 10 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENUIRONMENTAL,r INC Asbestos Business License #ZA- 0000164 2010 -0805- Asbestos November 01, 2010 Appendix D Recommendations Page 11 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL, INC Asbestos Business License #ZA- 0000164 2010- 0805- Asbestos November 01, 2010 RECOMMENDATIONS Recommended response actions have been selected for all Asbestos Containing Material present within the facility. Recommendation for response actions were arrived and are stated as follows: Non - Friable Category I Asbestos Containing Material is any material containing more than one percent asbestos that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure. Non - Friable Asbestos Containing Materials were found in the following samples: A) Category I Non - Friable Material Homogeneous Areas (HA) Sample Id Material Class Sample Description Sample Location Estimated Quantity HA -104 17 M Black NC duct seam mastic 9519 600 L.F. HA -106 21 M 9" x 9" grey floor tile & mastic under carpeting & Parkway Flooring 9523 Rear 1000 S.F. The above referenced Asbestos Contained Building Materials may be left in place if deemed to be in good condition & no repairs or renovations are scheduled which would disturb them. Care should be taken to ensure that the materials not be disturbed during repair, renovation or remodelling activities which could possibly release fibers into the air. To reduce the intrinsic liability to the owners, the ultimate solution may be to have the material removed. However, at the minimum, a formal Operations and Maintenance (O &M) Program is recommended to minimize potential fiber releases, monitor any future deterioration, and to ensure proper record keeping. Under the FDEP regulations, Category I non - friable asbestos - containing materials may be left in place during demolition underwet conditions. However, OSHAregulations require that disposal of asbestos- containing materials and debris is disposed of in a leak -tight and labeled container. The container may be plastic bags so long as the holding is leak - tight. All materials must be disposed of in a Class I landfill and manifest as Category I Non - Friable Asbestos containing material. To meet the requirements of a wet demolition, it is the responsibility of the demolition contractor to control any visible emissions by adequately applying water on the structure. Furthermore, the work practices for the demolition of a building containing asbestos must be in regulatory compliance with OSHA 1926.1101. All materials must be kept thoroughly wet or saturated during the demolition to assist in preventing the release of asbestos fibers. Page 12 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations AI`S FNVIRONMENTALI INC November 01, 2010 Asbestos Business License #ZA -0000164 2010 -0805- Asbestos A certified asbestos supervisor must perform or supervise the work. If during the demolition process visible emissions are observed, the asbestos - containing materials must then be abated. The regulations of the Occupational Safety and Health Administration (OSHA) applies to any detectable amount of asbestos in building materials or on facility components. This requirement covers worker training, work practices, and disposal methods. In summary, removing asbestos in a commercial setting requires training, specific work practices, and disposal methods for the asbestos and asbestos - containing debris. However, if Category I Materials have become friable or are in poor condition, they must be removed before demolition or renovation begins by a Florida Licensed Asbestos Abatement Contractor. When implementing the response actions, parties responsible for final selection should remember that actions shall be sufficient to protect HUMAN HEALTH AND THE ENVIRONMENT, but may also be the least burdensome method. Nothing in these recommendations should be construed as PROHIBITING or discouraging removal. This report is based upon conditions and practices observed at the property and information made available to the surveyor. This report does not intend to identify all hazards or unsafe practices, nor to indicate that other hazards or unsafe practices do not exist at the premises. In the event that demolition or renovation is deemed necessary, parties shall comply with all applicable laws, ordinances, rules and regulations of Federal, State and Local Governmental Agencies, including any National Emissions Standard Hazardous Air Pollutants (N.E.S.H.A.P.) Notification requirements. Page 13 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations A ns _NUnRoNMENTAL, INC Asbestos Business License #ZA -0000164 2010 -0805- Asbestos November 01, 2010 RECOMMENDATIONS Recommended response actions have been selected for all Asbestos Containing Material present within the facility. Recommendation for response actions were arrived and are stated as follows: Non - friable Category I Asbestos Containing Material is any material containing more than one percent asbestos that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure, and is likely to become crushed, crumbled, pulverized or reduced to powder during demolition or renovation. Non - Friable Category I Asbestos Containing Material were found in the following samples: A) Category I Non - Friable Material (Floor Sheeting) Homogeneous Areas (HA) Sample Id Material Class Sample Description Sample Location Estimated Quantity HA -107 24 M Yellow vinyl floor sheeting 9523 Bathroom 30 S.F. The above referenced Asbestos Contained Building Materials may be left in place if deemed to be in good condition & no repairs or renovations are scheduled which would disturb them. Care should be taken to ensure that the materials not be disturbed during repair, renovation or remodelling activities which could possibly release fibers into the air. To reduce the intrinsic liability to the owners, the ultimate solution may be to have the material removed. However, at the minimum, a formal Operations and Maintenance (O &M) Program is recommended to minimize potential fiber releases, monitor any future deterioration, and to ensure proper record keeping. The above building materials are considered Category I Non - Friable with a high potential for fiber release during demolition and /or renovation therefore must be removed before demolition or renovation begins by a Florida Licensed Asbestos Abatement Contractor. When implementing the response actions, parties responsible for final selection should remember that actions shall be sufficient to protect HUMAN HEALTH AND THE ENVIRONMENT, but may also be the least burdensome method. Nothing in these recommendations should be construed as PROHIBITING or discouraging removal. This report is based upon conditions and practices observed at the property and information made available to the surveyor. This report does not intend to identify all hazards or unsafe practices, nor to indicate that other hazards or unsafe practices do not exist at the premises. Page 14 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations A RS EAWIRONMENTAL, INC Asbestos Business License #ZA- 0000164 2010- 0805- Asbestos November 01, 2010 Appendix D Chain of Custody Laboratory Analytical Results Page 15 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Z£ 40 91. abed ET5 E4w'u'4%ne14,Imo. 12334 73 Court North West Palm Beach, Ft. 33412 (954) 238-0053 Ado** crY #ZA4IH}UO219 REPORT NUMBER: RA 0- 1187BSA LAB CODE: 961 •. REPORT OF CLIENT SUBMITTED BULK SAMPLE ANALYSIS CLIENT: ARS Environmental, Inc. #2010- 10097 Cleary Boulevard #305 Plantation, Florida 33324 SAMPLING DATE: 10/07/10 PROJECT: Commercial Buildings 9501 ,9517,9523,9531,9537,9541 &9545 N.E. 2 Ave. 1209 N.E 95 St. Miami Shores, Florida ANALYSIS DATE: 10111/10 Sample Number Anal. Init. Sample Item Description Asbestos Percentage & Type Identified- Percentage & Type Non- Asbestos Fibers Percentage Non -Fiber Mat. . 1 OKE Plaster NAD 1-2 Synthetic 98-99 Matrix 2 OKE Plaster NAD 1-2 Synthetic 98-99 Matrix 3 OKE Plaster NAD 1-2 Synthetic 9899 Matrix 4 DKE Plaster NAD - 1-2 Synthetic 98-99 Matrix 5 OKE Plaster NAD 1-2 Synthetic 98-99 Matrix 6 CAKE Plaster WAD • 1-2 Synthetic 98 -99 Matrix 7 OKE Insulation NAD 90 -95 Fiberglass 5 -10 Matrix 8 OKE insulation NAD 90-95 Fiberglass 5 -10 Matrix 9 OKE Insulation NAD 90-95 Fiberglass 5 -10 Matrix 10 r1KF Ing'dation Nip 90-05 FihPrglasa .r'i -1© Maier Dennis Emerson I.H. Microscopist 12334 73 COURT NORTH, ROYAL PALM BEACH, FL. 33412 (954)236 -0053 (561)333-0624 FAX (561) 333 -0684 in Mastic Portion Only Page 1 of 5 0 N Td Wd£17:80 0T0 o Z 0 O < (D CO O cT • (D N O cr - (D N • O O O Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ET$ E4t/' °4$4Z 14+4. 12334 73 Court North West Palm Beach, F!. 33412 (954) 238-0053 . 0044444. #z4l000021$ REPORT NUMBER: FL10- 1187BSA LAB CODE: 961 REPORT OF CLIENT SUBMITTED BULK SAMPLE ANALYSIS CLIENT: ARS Environmental,. Inc. #2010- • 10097 Cleary Boulevard #305 Plantation, Florida 33324 SAMPLING DATE: 10/07/10 PROJECT: Commercial Buildings • 9501,9517,9523,9531,9537,9541&9546 N.E. 2 Ave. If 209 N.E. 95 St. Miami Shores, Florida ANALYSIS DATE: 10/11/10 Sample Number Anal.. Init. Sample item Description Asbestos Percentage & Type Identified Percentage & Type Non- Asbestos Fibers Percentage Non -Fiber Mat. 11 DKE Ceiling Tile NAD 10-15 Cellulose 70-75 Fiberglass 10-20 Matrix 12 OKE Ceiling Tile MAD 10-15 Cellulose 70-75 Fiberglass 10 -20 Matrix 13 OKE Ceiling Tile MAD 10 -15 Cellulose 70 -75 Fiberglass 10.20 Matrix 14 DKE Ceiling Tile MAD 85 -90 Cellulose 10-15 Matrbc 15 DKE Ceiling Tile NAD 85-90 Cellulose 10 -15 Matrix 16 DKE Ceiling Tile NAD 85 -90 Cellulose 10 -15 Matrix 17 DKE Mastic . YES 2-3 Chrysotiie 97 -98 Matrix 18 DKE Mastic YES 2 -3 Chrysotile 97 -98 Matrix 19 DKE Mastic NAD 100 Matrix r 2n DKF Maatlr: NAD) inn Matrix Dennis Emerson 1.1-1. Microscopist *= In Mastic Portion Only Page 2 of 5 12334 73 COURT NORTH, ROYAL PALM BEACH, FL. 33412.(934)236 -0053 (561)333-0624 FAX (561)333 -0664 5 Ed Wd217:80 0'[0Z TT '100 O- N N O co c I 12334 73 Court North West Palm Beach, Fl. 33412 (954) 236-0053 r co 0) 0 N rn ET� E u.z40, I44.6. 3 CD • Xl v 0. 0 0 v N m v 0, 3 CD in 0. O O D 0 v 0 0. 5 Q1 O N Z£ 40 81. abed At40424, L:coa.cc #Z10000219 REPORT NUMBER: FL10- 1187BSA LAB CODE: 961 REPORT OF CLIENT SUBMITTED BULK SAMPLE ANALYSIS CUENT: ARS Environmental, Inc. #2010- 10097 Cleary Boulevard #305 Plantation, Florida 33324 SAMPLING DATE: 10107110 PROJECT: Commercial Buildings 9501,9517,9523,9531,9537,9541&9545 N.E 2 Ave. 1209 N.E. 95 St, Miami Shores, Florida ANALYSIS DATE: 10/11/10 Semple Number Anal. init. Sample Item Description Asbestos Percentage & Type identified Percentage & Type Non- Asbestos Fibers Percentage Non Fiber Mat. 21 DKE Floor Tile wlMastic YES 3-5 Chrysolite 95-97 Matrix 22 DKE Floor Tile w/Mastic YES 3-5 Chrysoti€e 95-97 Matrix 23 DKE Floor Tile w /Mastic YES 3 -5 Chrysotile 95-97 Matrix 24 DKE linoleum YES 10 -15 Chrysolite 15-20 Cellulose 65 -75 Matrix . 25 DKE Linoleum YES 10 -15 Chrysolite 15-20 Cellulose 65-75 Matrix`' 26 DKE Ceiling Tile NAD 3035 Fiberglass 35-40 Cellulose 25-36 Matrix 27 DKE Ceiling Tile NAD 30 -35 Fiberglass 35-40 Cellulose i 25-35 Matrix 28 DKE . Ceiling Tile NAD 30-35 Fiberglass 35.40 Cellulose 25-35 Matrix 29 DKE Ceiling Tile NAD 30 -35 Fiberglass 35-40 Cellulose 2545 Matrix 30 DKE Ceiling Tile _ NAD 30 -35 Fiberglass :15-40 Calh lnga 25-35 Matrix Dennis Emerson I.H. Microscopist `= in Mastic Portion Only Page 3 of 5 12334 73 COURT NORTH, ROYAL PALM REACH, Pt. 33412 (954) 236-0053 (561) 333-0624 FAX (561)333- ©694 ad WdP7:80 WOE TT '100 ET� E44v'u»t4*e44, 144.c. 1233473 Court North West Palm Beach, Fl. 33412 (954) 236 -0083 g14444+ lite.4ve4 #2A000021a REPORT NUMBER: FL10- 1187BSA LAB CODE: 961 REPORT OF CLIENT SUBMITTED BULK SAMPLE ANALYSIS CLIENT: ARS Environmental, Inc. #2010- 10097 Cleary Boulevard #305 Plantation, Florida 33324 SAMPLING DATE: 10/07/10 PROJECT: Commercial Buildings 9501 ,9517,9523,9531,9537,9541 89545 N.E 2 Ave. / 209 N.E. 95 St. Miami Shores, Florida ANALYSIS DATE: 10/11110 Sample Number Anal. hilt. Sample Item Description Asbestos Percentage & Type Identified Percentage & Type Non- Asbestos Fibers Percentage Non -Fiber Mat. 31 DKE Floor Tile w/Mastic NAD 100 Matrix 32 DKE Floor Tile wlMastic NAD 100 Matrix 33 DKE Floor Tile w/Mastic NAD 100 Matrix 34 DKE • Mastic YES <1 Chrysatile 100 Matrix 35 DKE Mastic YES <1 Chrysotite 100 Matrix 38 DKE Ceiling Tile NAD 30-35 Fiberglass 30 -35 Cellulose 30-40 Matrix 37 DKE Ceiling Tile NAD 30-35 Rberglass 30-35 Cellulose 30-40 Matrix 38 DKE Drywall w/Campound NAD 3-5 Fiberglass 7 -10 Cellulose 85 -90 Matrix t 39 DKE Drywall w/Compound NAD 3 -5 Fiberglass 7 -10 Cellulose 85 -90 Matrix 40 DKE Drywall w /Compound NAD 3-5 Fiberglass 7 -90 Ceiiuin A 85 -90 Matrix Dennis Emerson I.H. Microscopist . * = In Mastic Portion Only Page 4 of 5 12334 73 COURT NORTH, ROYAL PALM BEACH, FZ. 33412 (954)236 -0053 (561)333 --0624 FAX (561)333 -0694 U) tid Wd717:80 0T0Z TT '700 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Z£ OZ e6Bd ET� E4w4*1-e4Z Imo. 12334 73 Court North West Palm Beach, Fl. 33412 (954) 2.38 -0053 J44404,4- r.1.44,444 1 #Z4OQOO21$ REPORT NUMBER: FL10- 1187BSA LAB CODE: 981 REPORT OF CLIENT SUBMITTED BULK SAMPLE ANALYSIS CLIENT: ARS Environmental, Inc. #2010- 10097 Cleary Boulevard #305 Plantation, Florida 33324 SAMPLING DATE: 10/07/10 PROJECT: Commercial Buildings 9501 ,9517,9523,9531,9537,9541 &9545 N.E. 2 Ave. /209 N.E. 95 St. Miami Shores, Florida ANALYSIS DATE: 10111/10 Sample Number Anal. Init. Sample Item Description Asbestos Percentage & Type Identified Percentage & Type Non- Asbestos Fibers Percentage Non -Fiber Mat. 41 DKE Drywall w /Compound WAD 3-5 Fiberglass 7 -10 Cellulose . 85-90 Matrix 42 DKE Drywall wfCompound NAD 3-5 Fiberglass 7 -10 Cellulose 85-90 Matrix 43 DKE Drywall w/Compound NAD 3-5 Fiberglass 7 -10 Cellulose 85-90 Matrix 44 DKE Ceiling Tile NAD 30-35 Fiberglass 30 -35 Cellulose 30-40 Matrix 45 DKE Ceiling Tile MAD 30 -35 Fiberglass 30-35 Cellulose 30-40 Matrix 46 DKE Ceiling Tile NAD 30-35 Fiberglass 30 -35 Cellulose 30-40 Matrix 47 DKE Brick NAD 100 Matrix 48 DKE Brick NAD 100 Matrix 49 . DKE Concrete MAD 100 Matrix 50 13KF Cortrivitta MAI) i co Matrix Dennis Emerson 1.14. *= In Mastic Portion Only Microscopist 12334 73 COURT NORTH, ROYAL PALM BEACH, F.L. 33412 (984)236 --0053 (561) 333. -0624 PAX (561) 333 -.0684 Page 5 of 5 X z 0 in m 0 0 Sd Wdsv:se eti2E Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Z£ 40 6Z abed A RS ENVIRONMENTAL; W. CHAIN OF CUSTODY Page of Cy PLA4 AsbAw_Ais nu* Samples _ as Hour fa Now Raise Sea, Pay/noted & Pant Cu pun Da/ un %Ads Mini ad i ataxia <1% Turnaround Vim Illoricrested: Sem Day SamPliag Date: Samples Taken By Project Number: Project Location CCPAR2Cei 0 19 (1.4 1:5)3.7._1531 44,14 goi N.E-‘11651111.7 mow saw SPanake Trenelered 41411 Weateitinklith fri Date: : a • • Pi-t tiKkkollerCuscry tionelatgeMmitiVailan 01.*Milft miirrattratrarbOd r.ntio•ozo•utk• Telbecnnalr4Pitfe.xt mmhoa - Rece nth). relrxd 104*1 fri hJpr em •%; • • :TFii • • 1.4. : ; Sig: WOZIA X - Alaterial ago bands Rescriptins Sane& Mallon horea. Size • San* Waddles] Physical Damao PAW Wm RIP I. .1 Salo& lithe, S_____ 5 . Lit_f44 . _i141)(*.A.IA;IML \ (W *4, 1C/L ' fgPrVi. I- o in ( 1 - 111111111111 ‘4A MUM 41169i A IMINIMEI menimil 1M011 n mum 1111111311111 NI 1iv A IN IMO ti L L MA ni 111 1 VI .P IN 9 Eiri 11"1.4 . iti IN3Lveroks1 omets;51- 1 % nrill 1••4 1 , .1' . 1 0 112.1111111101111111111111111111111FA NM iv IIIIN mow saw SPanake Trenelered 41411 Weateitinklith fri Date: : a • • Pi-t tiKkkollerCuscry tionelatgeMmitiVailan 01.*Milft miirrattratrarbOd r.ntio•ozo•utk• Telbecnnalr4Pitfe.xt mmhoa - Rece nth). relrxd 104*1 fri hJpr em •%; • • :TFii • • 1.4. : ; Sig: WOZIA X wir4(a'1rw jJ u n r ARS EN / WNMENTAL, INC. Ann __ of _6 CHAIN OF CUSTODY P Asbe • s Bulk Samples Frwil iuu Shp R omibiaJ $ Pao Co art Ity uosl03 tin Fvi 1Hg Matrai rl.$: !hat nKxxaro <t% Thmar vnd ` lm* ReA,ytre.Rted: Slaw Doy 2a 4-b' • 41 How 72 Ho:x Sampling Date Samples Taken 8y: Project Number: ��ryflz• ����Gir��l t'+ 151 (f 4 d fj , gri'- Rale 1, 5,10 Sample 1d IMatmiai Mae Sire* Deeri*llan sample Malta* Apprrox. Sim Sample Calms Pigsled Damage meter damage Mareriai Contact Sarrlpfe Er :111,1 4., -ani,t r)Gwi TA.. as' N4 C. iUm,. i- r. I t A rgt ;sot 0 e) 11111111111111111 IIIIIIUII 1111111111111111111111 iv l d'"` L billi si\ 'IA RIM m ,� > ' V• ! Y 1 y13., ¶ .•�"f`i'' C1 tcirt isti� -DE 15-1. `1. L;w�a "fly f f egi1 -,1,...1.4,:, a r d MI 1111111118 Ea !% 14A1:114- C.. Ncl '506 rtsTh..) ki..4;ori U1/44111:1 VI i' ,, 1 f LA lullIllul II IL1NI1 I lig Nv ging Ma 41Oar 'Pransfered �y nefe: �OJ t«;84•v, 1•:1Creli • Frlmil* WOW= I brCepaT I NalkiffseMovii mamma vilanu3 "pad biMI F•rieW IthlmW hal rev bewrotknl et.Mtaq a UaaaW W pooh, hp NO PUPA" a I. Pg Recely ! r : r . _ ; . i : , ' ?aa,r II ^::r o : : ?.'•. • : , t ! ` i . • 95.3 -2_. :! tOe a kg' > I' 't!'?+':4,ri: `e..• •. :o- Lei Weigh :80 0SOE Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ZE 10 EZ a6ed R S ENVIRONMENTAL, INC. CHAIN OF CUSTODY P.tto.Stop Rarp3stari S Coin' rarp_wari on Rtado ',Medals Ptv &wt.. et% Sampling Date: Samples Taken fly Proptat Number: PLNI Asia Project Location luanlimurei Irma ri a quested: Some Day Bulk Samples #41 lour a I tug (1-01.4ftittcifti, ragoov(i q 50.1115-0i 96a31'46.-.3) ) 1537/9514 09_5V6 toxivc 4 WI • (Y59411(4- 'irArn+ 9MCil MOM Clegg ga.Vadada0Attcala Translated By' 115a 144740101Ma htigf6t13 4.4.101,1Acitts,. an .1 • • rta-7,3. Mid*: dIYInGa1rI 1ktMW tat WdJabe =Mat • Nags fitankd Saletay taaaattlal, pulataiatt tia.knai alwagla LW ka4 WO a atrif.t Racal ad a 'all la paw. krtf rarsmal • F**c)rie: 22i -2432 • 1.:Y.4 . •,_•15.11 3 0 Material Mee SOMPIO aoserlMies Sae* tentlea Sample lkallaien isierieii arterage %Yew amp • Pial-riiii Naiad saritpie Mild* 9 9 p orm RA ,v(1.,:l trAsr le , (*NIZPOJ MA 0 W L• O / MIEMMIS! 1111111111111 UM IMPUI 1 / 11111111111E1111111111 ekti4T-ari-05: } .-f•on 30 t pr, Y6110 vett wYP-Sittervt? t , , 12 4 , MIMI VI Illummig 9, t. a iva .v,op,iyti k.f. '&0 roAri 'Iles -04. vilciazy. q r" ,o1 MUM MI UMW MEIN . MIK PRIE11111111111 al 3 3 7 M 3 . r. itilkulWt 40rei , u-N it4 Eilliligiiil MOM Clegg ga.Vadada0Attcala Translated By' 115a 144740101Ma htigf6t13 4.4.101,1Acitts,. an .1 • • rta-7,3. Mid*: dIYInGa1rI 1ktMW tat WdJabe =Mat • Nags fitankd Saletay taaaattlal, pulataiatt tia.knai alwagla LW ka4 WO a atrif.t Racal ad a 'all la paw. krtf rarsmal • F**c)rie: 22i -2432 • 1.:Y.4 . •,_•15.11 3 0 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations L ,IRS Emmumisinum, INC, CHAIN OF CUSTODY Page_ of MN! Mime - • Sulk Samples Rake Sup Ruuumaud & Pti Cuunl u taJun Frial-Au )kale-ids Nil repot al <1% Turnaround rum Sluquentect Sutra faly Sempflag Date: Samples Takeo By: Project Number: gO I 0 Project Locator; 43l-lour 72 144w es6AnAmIPILL &kw, P5i elfg7 f6_1,9 532„95q 45115 tv6;,-.09tht 2-G9 N. e: cvd`o- pRtsour:,, fZ4 Sauuda Material . - - Saw* Sescriate SITIttAKS ViAtig3S). Sally la Location Va;I:04Cliff API/T66. Sze ( Slap Cauddlen C Physkal Damage Mut Damage NI Als1Orlal 14111041 Cantaal Mainly MIN I ant 1 (AMON Vt) , • e3g._ Pk LILL z4 IJ '3(1 a ri'l ATSW.k_ llki,t141,n, \ C (...i-300-- qpinti. 'Tilt 1-1 0 kjANOTOptif fi LIZ f L. IP-. al (5° ; aP teix oc4 cuuri -141WAY OV CItt %if IN, 30, 1 1.1>A III IIIII 1 i-A LA c , in r" 11 r : Y L 'lel . 3 . _ _ _ _ , _ 1 . _ A L V I A 1 5 4 2 4 4 . A , 7()Wq5116 P Z 0 1 •11 1) . , \ palm kilill Pi $1,r--- Ahr: •go s 14,6161616.= 6 atak2536tdateti *Dansfered By/ Malerfj • • IT lAtAlAWAPS. Date: h . W.06.1osyta 40407 TI.to rfkolettartal MenaTiltrovimetic antunertuataaa r.runtu gal roar tte ntreAeo. Mowed. ar n•Agat Weal* Isp4 Rarely • 1 • 46.1i 22F -1247 r.? • Eve 9'4 '2;7 240:: T,..7 68 WdLb:80 OTOZ TT -00 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Z£ Jo 5Z abed ARS EVVIIWNMENTA,C, 1i c CHAIN OF CUSTODY Page of Prune SwF Awls-sand Pubs f; uut clrgrpt tig 'lei nit Faith' Matti nha11 mix rlvr1% Turnaround Wain Requeetet : Sofro [toy Sampling Date: Samples Taken Slit Project Number_ 0 _•j i0 Project LocaVon CP•.. a.?Aiadgdated-C13- 3.rr-��� N5 qtr r` Qtr is t ¢4, Aw smurple et I3 stamrFal tdss e !inscription e Location am film $n l &Malan fop WSW liartge /Medal Conical Smile Fria t>aay `` Q, rd. - �i.+i1i94 ' 7 L 1 rr° ` 1 ty 111111111111 mums Z j ` % 1 riiiiiiiiivii MIIIIIIIIIIIIIMI iiiuuie 111 I Ili REFfil MIMI avii 14,11t,q + ,I ,1`d (Wm() rdloif P&_.. y, )„ 1? K1 0 , v t I AM" 0111116f 5 - 1 . ffzec. (irsae6 saot6f 1` 11,1%) - utrillpilellifill -. 4 I m IdkcMmev,s:ktctuls s+1 IV: t �Tf wan. *I nameedre. wad bs inzei. rmlarbrtadp erswp mitred roit it:arnnarresoter _���r Date: t j l Rea* _ _- _ _ RrISiH,til AcItIa :: I (11 7 CANT.; BO. P:rraxti. V7.41.3 • Plat tt:rtb. • rflrstra 72324 • mune• iatulr ?'l. r .'4r • Far: 053- •!4&O a 7r-:i €:rsr. Kum .13c7t 22r -2401 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Z£ to 9Z a6ed ARS ENUMONMENAL, CHAIN OF CUSTODY Page_ of PLM Asbe s Bulk Samples P 0 W,. Slop Req.t000d & Point Cool mquOtIed on FiLh Moto4olg Owl npr < Sampling Date. Samples Taken Sr Project Number: C.P12.01-1 a010-' Threareund Tires Penenstati Steno (Icy 24 Hot 48Hour 72 Hour Project Location CAVOVIL 611.1.AWS. el Ail SE1_14:1050.55.2)Afila"/ g+ 0q 1'1, 9'53/UV PON SiskEla haripie 111 Sample Inscription sf ham& tecettan IWOL bean Size Castilian kATN CS) flaoct' C ' AM( '11 ce.50. Velar Dosage MUM MUM MAIM MINERIENI kvlr Ill I Ili 11111 Mr Pi-G I.P.istt47/01,1) Otago, 4-4,400( ty "kf,V- LaE)()i) cuRliAftc2saTir 1-7 ra if „rc Au_t_00,c-, 0 fjQ 1A1 Qame S--thrtwialitairaa 7•11 l&4 11•Visulevardlotos WWI* ElKvoloota-Cumov11100441•401roralThiewleltho.olienve.raef nom ourtiet few •plemplakm.flir rogirha treated, tvtaSiEe4 ub1ud ■•.4.414; reilinutto factor tent Translated Dr Mat 4 Ark Date: /1.9 (.1Y:4C Cleary- So-.11eArQ PiaiVOOOn, 0 Dee@ 0401 ::1:3P4 • Phrrirf (1.45at • CM: Sr.: 227 :"-4(e,1 • Tot 1"eo 0 23Y -2401 Tid Wd67:80 OWE TT '700 A RS ENVIRONMENTAL,, INC Asbestos Business License #ZA- 0000164 2010- 0805 - Asbestos November 01, 2010 Appendix E Inspectors Certificate & Business License Page 27 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL" INc Asbestos Business License #ZA- 0000164 2010 -0805- Asbestos November 01, 2010 t:4 Asbestos Business License STATE OF FLORIDA �DQ ggi�pp DEPARTMENT OF ASBENEET S LICENSING REGULATION SEQ# L09091403687 DATE T3ATCH, UdSDIfl LICENSE NBR !09/16/2009 09,8043726 1ZA0000164 The ASBESTOS BUSINESS ORGANIZATION Named below IS LICENSED Under the provisions of Chapter 469 PS. Expiration date: NOV 30, 2011 ARS ENVIRONMENTAL. INC. TIMOTHY CAUGBEY 10097 CLEARY BOULEVARD PLANTATION FL 33324 CHARLIE CRIST CHARLES W. DRAGO GOVERNOR SECRETARY AW DISPLAY AS REQUIRED UY Page 28 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations Asbestos Consulting • Lead Assessments • Radon Gas Measurements • pIow • Allen° J!vaoopu ZE Jo 6Z 866d Traini .74$11'7,7217CERT4tiR NXI NM 'MI Avolue, fun Laudadqle. Flutida, WI I This is to Certify that 12 Ai Fluppin 111097 Cleary Lilvd s3D5 Phaitation,FL has successfully completed an English Ixetz-ittes - IN toctital iRefreabtx 12-Feb-10 TO 12-Feb-10 essactokr4 tB.0 nxionatt. baiting BOr 4C4Mttattliefi UMIOF TA T1ft It WIDAAC Provider 0451 Treineap: Mart Mack ruining Addrem: COO NW :lib Ave. Kal Laudentak FL 333 n Suoceselui course eunipletion based on exam score on. 02f t tv I n 1.) �z —" 0 o < al CO cr cri cji) 0 A RS ENWRONMENTALI INC Asbestos Business License #ZA- 0000164 2010 -0805- Asbestos November 01, 2010 Appendix F General Terms & Conditions Page 30 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations .4 RS ENVRRONMENTAL, INC Asbestos Business License #ZA- 0000164 2010- 0805 - Asbestos November 01, 2010 GENERAL TERMS AND CONDITIONS Scope Of Work ARS ENVIRONMENTAL, INC., inspection is limited and non - destructive in'nature, Any conditions or materials which were not able to be visually observed on the surface, or in easily accessible areas, were not inspected and may differ from those observed. It was not within the scope of this investigation to remove surface materials to investigate portions of the structure or materials which lay beneath the surface. Our selection of sample locations and frequency is based upon our observations and the assumption that like materials in the same area are homogeneous. This inspection report is the result of a diligent search of the facility for Asbestos Containing Building Materials (A.C.B.M.). The purpose of this inspection was to identify those materials which may pose a health hazard to occupants of a building and impart future liability to the Owners and Insurers of the property. However, we do not claim to have identified all of the Asbestos Contained Building Materials present in the facility. Materials such as underground pipes, any material inside walls, ceilings, floors or other enclosed and inaccessible areas were not sampled and are not covered in this report. This report is designed to aid the building Owner, Architect, Construction Manager, General Contractors and potential Asbestos Abatement Contractors in locating ASBESTOS CONTAINING BUILDING MATERIALS. Under no circumstances is this report to be utilized as a proposal or a project specification document. This report is based upon conditions and practices observed at the property and information made available to the surveyor. This report does not intend to identify all hazards or unsafe practices, nor to indicate that other hazards or unsafe practices do not exist at the premises. Right Of Entry. The client will provide for right of entry of ARS ENVIRONMENTAL, INC., personnel in order to complete the above referenced work. Invoices ARS ENVIRONMENTAL, INC., will submit invoices to client upon completion of services. Ownership Of Documents All reports, field data, field notes, laboratory test data, calculations, estimates and any other documents prepared by ARS ENVIRONMENTAL, INC., as instruments of service shall remain the property. of ARS ENVIRONMENTAL, INC. Page 31 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations ARS ENVIRONMENTAL, INC Asbestos Business License #ZA- 0000164 2010- 0805 - Asbestos November 01, 2010 Assumptions And Limitations The results, finds, conclusions and recommendations expressed in this report are based only on conditions which were observed during inspections by this report. ARS ENVIRONMENTAL, INC., makes no representation, or assumptions as to past conditions or future occurrences. Assigns Neither the client nor ARS ENVIRONMENTAL, INC., may delegate, assign, sublet or transfer his duties or interest in this agreement without the written consent of the other party. Roof Cuts To obtain accurate information in a roof investigation, roof cuts (approximately four inch (4 ") squares), may be deemed necessary. It is the responsibility of our client to make appropriate repairs to these roof cuts, using materials consistent with the roofing system and in accordance with any existing material manufacturer's warranties. A roofing contractor or maintenance personnel selected by our client should be on the roof to make any necessary repairs at the time the samples are being obtained. Although, every attempt will be made to make these repaired areas water tight, ARS ENVIRONMENTAL, INC., will in no way be responsible for any water damage to the roofing system, building, or it's contents resulting from ARS ENVIRONMENTAL, INC temporary repairs. Disclaimer If in the course of a renovation or demolition activity, suspect materials become exposed, ALL FURTHER ACTIVITY SHOULD IMMEDIATELY CEASE AND THE ASBESTOS FORM STATUS OF THE MATERIAL SHOULD BE DETERMINED BEFORE PROCEEDING Page 32 of 32 Asbestos Consulting • Lead Assessments • Radon Gas Measurements • Indoor Air Quality • Mold Investigations