EL-12-14Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 173209 Permit Number: EL- 1 -12 -14 Scheduled Inspection Date: May 10, 2012 Inspector: Devaney, Michael Owner: Job Address: 9190 NW 1 Avenue Miami Shores, FL Project: <NONE> Contractor: SKY ELECTRIC, INC. Permit Type: Electrical - Residential Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1131010160030 Phone: 305 -542 -0060 Building Department Comments ELECTRICAL WORK INTERIOR REMODEL Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 168434. Label panel. OUTSIDE g. f. i. TO BE t.p. /w.p.. A.C.C.U. max fuse 35 amp. has 40 amp.. /6) SiL kc-f7 May 09, 2012 For Inspections please call: (305)762 -4949 Page 15 of 25 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305). 762.4949 BUILDING PERMIT A1313LICATION FBC 20 Permit Type: ELECTRICAL Permit No. j 11, i 0 , _ .fit Master Permit No. 401)-441 Owner's Name (Fee Simple Titleholder) .S/JDAl'f 1a tag teC Phone # Owner's Address f 7 i2 rim / 4 t/?' City p(Ade —C �t -�,` T r • State Tenant/Lessee Name Email j we S Ycdr frcs !Sr 9 Zip ?T /�3 c∎ ri t Io/L • �y n.� Job Address (where the ork is being done) 9 / 9 0 ti ("ti City Miami Shores Village County Miami- -Dade Zip 3g/ S !� .1i 3 I — Cie —00, Phone # Sf OIt.t l -s/J nit S FOLIO / PARCEL # Is Building Historically Designated YES NO Contractor's Company Name SA' g 4 -acs f Contractor's Address 9® /1 16-6? J City /�� State ft. Qualifier Name / C.444 -z 4,1,0 Phone # State Certificate or Registration No. / &C f JOGsl- -76 Certificate of Competency No. Flood Zone Phone # 30 .) ' 2 °0 016 0 Zip 37/67 Contact Phone , Z °� G4 G E -mail ; 5kJ ?ID c 9 ,U' .f,V a (//w Architect/Engineer's Name (if applicable) 5 e Value of Work For this Permit $ Type of Work: DAdi. 'on Describe Work: FU-7)t Squ 0Alteratiox9ajAJ5 ew ctVJi.41,0Phone # - 2 g g '-` , / Linear Footage) i' Work: Repair/Replace ❑ Demolition Submittal Notary $ Scanning $ Double Fee $ \'Si9i9u • 'Ji9l�F"9tY7R�X�,QX7rfYQStx�a4� as,ww.! +R fruisei,n nic,, y Structural Review. $ * * * * ** ** Fees************* * * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** 2 /Go /f- -iCF $ Training/Education Fee $ Radon $ DPBR $ Violation date: Total Fee Now Due $ 94E11- See Reverse side —1• CO /CC $ Technology Fee $ Bond $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a re- inspection fee will be charged. Signature - Signa er or Agent Contrac The foregoing ins ' ent was acknowledged before me this The foregoing instrument was • • l owledged before me this (9... day of b1j 20 /) , by :3-ek S ���/ . ' , day of 20 1 2., by 1((1 rJl 14)4-5 who is personally known to me or who has produced r)( who is personally known to me or who has produced 1)50 1..) - LK5 ? (4 U As iden fication alnd hw o' did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: P L My Commission Expires: _ _ My :i tii'irt JAMAL L SCOTT 1 ." MY COMMISSION # EE076226 � My Comm. Emma Mar 31. 2015 J (407) 398-0153 arideNotaaServlce.com /c/Z4./ APPROVED BY ,): ; f Plans Examiner NOTARY : LIC: Sign: Print: REDRINA S. EDMONDSON" Notary Public - State of Flow Engineer (Revised 07 /10 /07)(Revised 06/10/2009) Zoning 'Clerk checked Charles. C■ Mitchell CONSULTING ENGINEER �% P.E. 11127 F AT1cNAL ANALYSIS AND ...:...::..:: ENGINEERING DESIGN CALCULATIONS COMPLY WITH FLORIDA ADMINISTRATIVE CODE SECTION 6 1 G 1 5-23 NEW WINDOWS AND DOORS AT 91 90 NW 1 AVE. MIAMI SHORES,FLORIDA CHARLES C. MITCHELL P .E. IF 1 1 1 Z7 SEAL: (r %v PAGES 1 TO 4 WINDO5 v1 -1 Detailed Wind Load Design (Method 2) per ASCE 7 -05 Analysis by: Charles C. Mitchell Company Name: Description: 9190 NW 1 Ave, Miami Shores FL User Input Da Structure Type Basic Wind Speed (V) 146 Struc Category (I, II, III, or I 11 Exposure (B, C, or D) C Struc Nat Frequency (n1) 1 Slope of Roof 3.0 Slope of Roof (Theta) 14.0 Type of Roof Hipped Kd (Directonality Factor) 0.85 Eave Height (Eht) 10.83 Ridge Height (RHt) 15.50 Mean Roof Height (Ht) 13.16 Width Perp. To Wind Dir (B 40.00 Width Paral. To Wind Dir (1 52.00 Building mph Hz :12 Deg ft ft ft ft ft Calculated Parameters Type of Structure Height/Least Horizontal Dim 0.33 Flexible Structure No fated Parameters Importance Factor 1 1 Hurricane Prone Region (V >100 mph) Table 6 -2 Values Alpha = zg = 9.500 900.000 At = Bt = 0.105 1.000 Bm = 0.650 c= 0.200 1= 500.00 ft Epsilon = Zmin = 0.200 15.00 ft Gust Factor Category 1: Rigid Structures - Simplified Method Gust1 'For rigid structures (Nat Freq > 1 Hz) use 0.85 1 0.85 Gust Factor Category II: Rigid Structures - Complete Analysis Zm Zmin 15.00 ft Izm Cc * (33/z) ^0.167 0.2281 Enclosed Buildings Lzm _ I *(zm /33) ^Epsilon 427.06 ft Q (1/(1 +0.63 *((Min(B,L) +Ht) /Lzm) ^0.63)) ^0.5 0. 925 *((1 +1.7 *Izm *3.4 *Q) /(1 +1.7 *3.4 *Izm)) 0.9247 0.8854 Gust2 Gust Factor Summary G (Since this is not a flexible structure the lessor of Gust1 or Gust2 are used 1 0.851 Fig 6 -5 Internal Pressure Coefficients for Buildings, Gcpi Condition Gc • 1 Max + Max - Open Buildings 0.00 0.00 Partially Enclosed Buildings 0.55 -0.55 Enclosed Buildings 0.18 -0.18 Enclosed Buildings 0.18 1 -0.18 Developed by Meca Enterprises, Inc. Copyright 2006 11/1/2011 Page No. 1 of 4 WINDO5 v1 -1 Detailed Wind Load Design (Method 2) per ASCE 7 -05 6.5.12.2.1 Design Wind Pressure - Buildings of All Heights Elev Kz Kzt qz Pressure (Ib /ft^2) Windward WaII* 0 Kht Ib /ft^2 +GCpi -GCpi 15.5 0.85 1.00 39.65 19.87 34.05 15 0.85 1.00 39.37 19.69 33.86 Figure 6 -6 - External Pressure Coefficients, Cp Loads on Main Wind -Force Resisting Systems (Method 2) L z Theta. h L Variable Formula Value (/nits Kh 2.01 *(15 /zg) ^(2/Alpha) 0.85 Kht Topographic factor (Fig 6-4) 1.00 Qh .00256 *(V) ^2 *I *Kh *Kht *Kd 39.37 psf Khcc Comp & Clad: Table 6 -3 Case 1 0.85 Qhcc .00256 *V ^2 *I *Khcc *Kht *Kd 39.37 psf Wail Pressure Coefficients, Cp Surface Cp Windward Wall (See Figure 6.5.12.2.1 for Pressures) 0.8 Roof Pressure Coefficients, Cp Roof Area (sq. ft.) Reduction Factor 1.00 Calculations for Wind Normal to 40 ft Face Additional Runs may be req'd for other wind directions Cp Pressure (psf) GCpi -GCpi Leeward Walls (Wind Dir Normal to 40 ft wall) Leeward Walls (Wind Dir Normal to 52 ft wall) Side Walls -0.44 -0.50 -0.70 -21.81 -23.82 -30.52 -7.64 -9.65 -16.34 Roof - Wind Normal to Ridge (Theta > =10) Windward - Min Cp Windward - Max Cp Leeward Normal to Ridge Overhang Top (Windward) Overhang Top (Leeward). Developed by Meca Enterprises, Inc. Copyright 2006 - for Wind Normal to 40 ft face -0.54 -0.04 -0.46 -0.54 -0.46 -25.24 -8.35 -22.50 -18.16 -15.41 -11.07 5.82 -8.32 -18.16 -15.41 11/1/2011 Page No. 2 of 4 WINDO5 v1 -1 Detailed Wind Load Design (Method 2) per ASCE 7 -05 Overhang Bottom (Applicable on Windward only) 0.80 26.77 26.77 Roof - Wind Parallel to Ridge (All Theta) - for Wind Normal to 52 ft face Dist from Windward Edge: 0 ft to 26.32 ft - Max Cp Dist from Windward Edge: 0 ft to 6.58 ft - Min Cp Dist from Windward Edge: 6.58 ft to 13.16 ft - Min Cp Dist from Windward Edge: 13.16 ft to 26.32 ft - Min C Dist from Windward Edge: > 26.32 ft -0.18 -0.90 -0.90 -0.50 -0.30 -13.11 -37.21 -37.21 -23.82 -17.13 1.06 -23.03 -23.03 -9.65 -2.95 Kh = Kht = Qh = Theta = * Horizontal distance from windward edge Figure 6 -10 - External Pressure Coefficients, GCpf Loads on Main Wind -Force Resisting Systems w/ Ht <= 60 ft 2.01 *(15 /zg) ^(2/Alpha) Topographic factor (Fig 6 -2) 0.00256*(V)A2*ImpFac*Kh*Kht*Kd Angle of Roof 0.85 1.00 = 39.37 14.0 Deg Trans rs n Torsionid Load Wind Pressures on Main Wind Force Res sting System Surface GCpf +GCpi -GCpi qh (psf) Min P (ps Max P (psf) 1 0.48 0.18 -0.18 39.37 11.73 25.91 2 -0.69 0.18 -0.18 39.37 -34.26 -20.08 3 -0.44 0.18 -0.18 39.37 -24.25 -10.08 4 -0.37 0.18 -0.18 39.37 -21.81 -7.64 5 -0.45 0.18 -0.18 39.37 -24.81 -10.63 6 -0.45 0.18 -0.18 39.37 -24.81 -10.63 1E 0.72 0.18 -0.18 39.37 21.42 35.59 2E -1.07 0.18 -0.18 39.37 -49.22 -35.04 3E -0.63 0.18 -0.18 39.37 -31.74 -17.56 4E -0.56 0.18 -0.18 39.37 -28.98 -14.80 * p = qh * (GCpf - GCpi) Developed by Meca Enterprises, Inc. Copyright 2006 11/1/2011 Page No. 3 of 4 WINDO5 v1 -1 Detailed Wind Load Design (Method 2) per ASCE 7 -05 Figure 6 -11 - External Pressure Coefficients, GCp Loads on Components and Cladding for Buildings w/ Ht <= 60 ft a= 4 =_> a Hipped Roof 7 < Theta < =27 4.00 ft Double Click on any data entry line to receive a help Screen Component width (ft) Span (ft) Area (ft^2) Zone GCp Wind Press (Ib /ft^2) Max Min Max Min window 1 3.08 4.16 12.81 4 0.98 -1.08 45.71 -49.65 window E1 3.08 4.16 12.81 4 0.98 -1.08 45.71 -49.65 window E1 3.08 4.16 6.65 5 1.00 -1.40 46.46 -62.21 window E2 3.08 ' 3.16 9.73 4 1.00 -1.10 46.46 -50.40 window E3 3.08 2.16 6.65 4 1.00 -1.10 46.46 -50.40 window E3 3.08 2.16 6.65 5 1.00 -1.40 46.46 -62.21 Door 1 3 6.67 20.01 4 0.95 - 1.05 44.37 -48.30 Door 2 3 6.67 20.01 _ 4 0.95 - 1.05 44.37 -48.30 Note: * Enter Zone 1 through 5, or 1H through 3H for overhangs. Developed by Meca Enterprises, Inc. Copyright 2006 11/1/2011 Page No. 4 of 4 • FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Pann Residence Builder Name: TBD Street: 9190 NW 1st Ave Permit Office: Miami City, State, Zip: Miami Shores , Fl , 33150- Permit Number. NA Owner: Mr James Pann Jurisdiction: 232600 Design Location: FL, Miami 1. New construction or existing Existing (Projected 2. Single family or multiple family Single-family 3. Number of units, if multiple family 2 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area (ft2) 1487 7. Windows(365.3 sqft.) Description Area a. U- Factor: Sgl, U =1.03 365.29 ft2 SHGC: SHGC =0.29 b. U- Factor: N/A ft2 SHGC: c. U- Factor: N/A ft2 SHGC: d. U- Factor: N/A ft2 SHGC: e. U- Factor: N/A ft2 SHGC: 8. Floor Types (1486.0 sqft.) Insulation Area a. Slab -On -Grade Edge Insulation R =0.0 1486.00 ft2 b. N/A R= ft2 c. N/A R= ft2 9. Wall Types (1426.0 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R =4.1 1319.80 ft2 b. Concrete Block - Int Insul, Adjacent R =4.1 106.25 ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types (1363.8 sqft.) Insulation Area a. Under Attic (Unvented) R =30.0 1363.80 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts a. Sup: Attic Ret: Interior AH: Interior Sup. R= 6,175 ft2 12. Cooling systems a. Central Unit Cap: 36.2 kBtu/hr SEER: 15.5 13. Heating systems a. Electric Strip Heat Cap: 24.0 kBtu/hr COP: 1 14. Hot water systems a. Electric Cap: 50 gallons EF: 0.95 b. Conservation features None 15. Credits Pstat Glass /Floor Area: 0.246 Total As -Built Modified Loads: 38.13 PASS Total Baseline Loads: 49.23 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. / PREPARED BY: �1� �� {i 1C41 Review of the plans and 0° 824, specifications covered by this calculation indicates compliance y r �n f ,�„ asa,s' with the Florida Energy Code. _ �. Before construction is completed'. _ - ,• :x DATE. if- of- I1 this building will be inspected for r compliance with Section 553.908 Florida Statutes. ' ' BUILDING OFFICIAL. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT. DATE. DATE. 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 1 of 6 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 2 of 6 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New /Existing: Comment: Pann Residence FLAsBuilt Mr James Pann 2 TBD Miami 232600 Single- family Existing (Projected) Bedrooms: 3 Conditioned Area: 1487 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Adress Type: Lot # Block/SubDivision: PlatBook: Street: County. City, State, Zip: Street Address 9190 NW 1st Ave Miami -Dade Miami Shores , FI, 33150 - CLIMATE / V Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI_INTL AP 1 51 90 75 70 149.5 56 Low FLOORS V# Floor Type Perimeter Perimeter R -Value Area Joist R -Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation Slab -On -Grade Edge Insulation 36.33 ft 0 0.01 ft 0 6.8333 ft 0 17.75 ft 0 42.5 ft 0 7.083 ft 0 0.01 ft 0 10.667 ft 0 32 ft 0 70 ft2 241 ft2 202 ft2 339 ft2 240 ft2 125 ft2 27 ft2 42 ft2 200 ft2 0 0 1 0 0 1 1 0 0 1 0 0 0 0 1 1 0 0 0.5 0 . 0.5 0.5 0 0.5 0 0 1 2 3 4 5 6 7 8 9 ROOF V/ # Type Materials Roof Gable Roof Area Area Color Solar Absor. Deck Tested Insul. Pitch 1 Hip Flat tile/slate 1533 ft2 0 ft2 Light 0.96 No 30 14 deg ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1487 ft2 N N 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 2 of 6 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 3 of 6 CEILING V# Ceiling Type R -Value Area Framing Frac Truss Type 1 Under Attic (Unvented) 30 200 ft2 0.11 Wood 2 Under Attic (Unvented) 30 42 ft2 0.11 Wood 3 Under Attic (Unvented) 30 27 ft2 0.11 Wood 4 Under Attic ( Unvented) 30 125 ft2 0.11 Wood 5 Under Attic ( Unvented) 30 240 ft2 0.11 Wood 6 Under Attic (Unvented) 30 339 ft2 0.11 Wood 7 Under Attic (Unvented) 30 79.83 ft2 0.11 Wood 8 Under Attic (Unvented) 30 241 ft2 0.11 Wood 9 Under Attic (Unvented) 30 70 ft2 0.11 Wood WALLS / Cavity Sheathing Framing Solar �/ # Omt Adjacent To Wall Type R -Value Area R -Value Fraction Absor. 1 N Exterior Concrete Block - Int Insul 4.1 107.25 ft2 0.06 0 0.75 2 E Exterior Concrete Block - Int Insul 4.1 127.0833 0.06 0 0.75 3 S Exterior Concrete Block - Int Insul 4.1 61.11111 0.06 0 0.75 4 N Exterior Concrete Block - Int Insul 4.1 38.88888 0.06 0 0.75 5 N Exterior Concrete Block - Int Insul 4.1 69.44444 0.06 0 0.75 6 E Exterior Concrete Block - Int Insul 4.1 153.4722 0.06 0 0.75 7 W Exterior Concrete Block - Int Insul 4.1 150.6944 0.06 0 0.75 8 E Exterior Concrete Block - Int Insul 4.1 31.94444 0.06 0 0.75 9 S Exterior Concrete Block - Int Insul 4.1 111.1111 0.06 0 0.75 10 E Exterior Concrete Block - Int Insul 4.1 116.6666 0.06 0 0.75 11 S Exterior Concrete Block - Int Insul 4.1 118.75 ft2 0.06 0 0.75 12 W Exterior Concrete Block - Int Insul 4.1 44.44444 0.06 0 0.75 13 S Exterior Concrete Block - Int Insul 4.1 31.94444 0.06 0 0.75 14 W Exterior Concrete Block - Int Insul 4.1 156.9444 0.06 0 0.75 15 N Garage Concrete Block - Int Insul 4.1 106.25 ft2 0.06 0 0.01 DOORS V# Omt Door Type Storms U -Value Area 1 E Insulated None 0.460000 22.77777 2 N Insulated None 0.460000 22.77777 WINDOWS Orientation shown is the entered, asBuilt orientation. / Overhang V # Omt Frame Panes NFRC U- Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N Metal Low -E Single Yes 1.03 0.29 N 29.29166 2 ft 0 In 2 ft 0 in HERS 2006 None 2 E Metal Low -E Single Yes 1.03 0.29 N 25.69444 2 ft 0 In 2 ft 0 in HERS 2006 None 3 N Metal Low -E Single Yes 1.03 0.29 N 6.680555 2 ft 0 In 2 ft 0 in HERS 2006 None 4 N Metal Low -E Single Yes 1.03 0.29 N 19.52777 2 ft 0 in 2 ft 0 in HERS 2006 None 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 3 of 6 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 4 of 6 WINDOWS Orientation shown is the entered, asBuilt orientation. / V # Omt Frame Panes NFRC U- Factor SHGC Storms Overhang Area Depth Separation Int Shade Screening 5 W Metal 6 E Metal 7 S Metal 8 E Metal 9 E Metal 10 S Metal 11 S Metal 12 W Metal 13 W Metal 14 W Metal Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N Low -E Single Yes 1.03 0.29 N 29.29166 2 ft 0 in 2 ft 0 in 25.69444 2 ft 0 in 2 ft 0 in 12.84722 2 ft 0 in 2 ft 0 in 51.38888 2 ft 0 in 2 ft 0 in 38.54166 2 ft 0 in 2 ft 0 in 25.69444 2 ft 0 in 2 ft 0 in 12.84722 2 ft 0 in 2 ft 0 in 6.680555 2 ft 0 in 2 ft 0 in 41.11111 2 ft 0 in 2 ft 0 in 40 ft2 2 ft 0 in 2 ft 0 in HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 None None None None None None None None None None INFILTRATION & VENTING / V Method SLA CFM 50 ACH 50 ELA EgLA - Forced Ventilation - SupplyCFM Exhaust CFM Run Time Fraction Fan Watts Default 0.00036 1404 6.83 77.1 145.0 100.0 cfm 0.0 cfm 0 0 GARAGE V# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 304.1388 ft2 304.1388 ft2 48 ft 8 ft 4.1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit Split SEER: 15.5 36.2 kBtu/hr 1086 cfm 0.71 sys #1 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Strip Heat None COP: 1 24 kBtu/hr sys #1 HOT WATER SYSTEM V# System Type EF Cap Use SetPnt Conservation 1 Electric 0.95 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Cert # Company Name System Model # Collector Model # Area Storage Volume FEF None None ft2 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 4 of 6 DUCTS / — Supply — — Retum — Air Percent V # Location R -Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 175 ft2 Interior 10 ft2 Default Leakage Interior (Default) c (Default) % TEMPERATURES Programable Thermostat. Y Ceiling Fans: Cooling RI Jan Feb [X] Mar A r (X] Ma Heating Jan 7XC Feb [X] Mar pX Apr [X] May Ventin Jan [[�Xl1 Feb [X] Mar [[�X]] Apr [[XX]] May Jun [X] Jul [[XX]] Au Se C Jun [X] Jul [X] Au(C Sep [[�X]] Jun [X] Jul [[XX]] Aug [[�X]] Sep Oct ((XX]] Nov p Oct [X] Nov (7(1 Oct [(XX]] Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEN) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (W EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 5 of 6 1 FORM 1100A -08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 9190 NW 1st Ave Miami Shores, FI, 33150- PERMIT #: NA INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm /sq.ft. window area; .5 cfm /sq.ft. door area. '...- Exterior & Adjacent Walls NI106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows /doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top /bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. 4q 1 Floors NI106.AB.1.2 Penetrations /openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. 'r' Ceilings NI106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. ✓ Recessed Lighting Fixtures NI 106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. '' Multi -story Houses NI106.AB.1.2 Air barrier on perimeter of floor cavity between floors. NA Additional Infiltration reqts NI106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. ✓ OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters NI112.AB.3 Comply with efficiency requirements in Table NI112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. ✓ Swimming Pools & Spas NI112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. 4q 1 Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. N A Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section NI 110.AB. Ducts in unconditioned attics: R -6 min. insulation. ✓ HVAC Controls NI107.AB.2 Separate readily accessible manual or automatic thermostat for each system. ✓ Insulation N1104.AB.1 N1102.B.1.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. 1/ 10/28/2011 8:59 PM EnergyGauge® USA - FlaRes2008 Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows*' a. U- Factor: SHGC: b. U- Factor. SHGC: c. U- Factor: N/A SHGC: d. U- Factor: N/A SHGC: e. U- Factor. N/A SHGC: Description SgI, U =1.03 SHGC =0.29 N/A 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9190 NW 1st Ave, Miami Shores, FI, 33150- Existing (Projected Single - family 2 3 No 1487 Area 365.29 ft2 Insulation Area R =0.0 R= R= ft2 ft2 ft2 ft2 1486.00 ft2 ft2 ft2 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Concrete Block - Int Insul, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Unvented) b. N/A c. N/A Insulation R =4.1 R =4.1 R= R= Insulation R =30.0 R= R= Area 1319.80 ft2 106.25 ftz ft2 ft2 Area 1363.80 ft2 ft2 ft2 11. Ducts a. Sup: Attic Ret: Interior AH: Interior Sup. R= 6,175 ft2 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City /FL Zip: Cap: 36.2 kBtu/hr SEER: 15.5 Cap: 24.0 kBtu/hr COP: 1 Cap: 50 gallons EF: 0.95 Pstat *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638 -1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the 'Label required by Section 13- 104.4.5 of the Florida Building Code, Building, or Section 82.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, If multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows""' a. U- Factor: SHGC: b. U- Factor: SHGC: c. U- Factor: N/A SHGC: d. U- Factor: N/A SHGC: e. U- Factor: N/A SHGC: Description Sgl, U =1.03 SHGC =0.29 N/A 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9190 NW 1st Ave, Miami Shores, FI, 33150- Existing (Projected Single - family 2 3 No 1487 Area 365.29 ft2 ft2 ft2 ft2 ft2 Insulation Area R =0.0 1486.00 ft2 R= ft2 R= ft2 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Concrete Block - Int Insul, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Unvented) b. N/A c. N/A Insulation Area R =4.1 1319.80 ft2 R =4.1 106.25 ft2 R= ft2 R= ft2 Insulation Area R =30.0 1363.80 ft2 R= ft2 R= ft2 11. Ducts a. Sup: Attic Ret: Interior AH: Interior Sup. R= 6, 175 ft2 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City /FL Zip: Department of Community Affairs at (850) 487 -1824. Cap: 36.2 kBtu/hr SEER: 15.5 Cap: 24.0 kBtu/hr COP: 1 Cap: 50 gallons EF: 0.95 Pstat """`Label required by Section 13- 104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 Residential System Sizing Calculation Summary Project Title: Pann Residence Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- 10/28/2011 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(7 ft) Temp Range(L) Humidity data: Interior RH (50 %) Outdoor wet bulb (77F) Humidity difference(58gr.) Load Winter design temperature(MJ8 99 %) 50 F Summer design temperature(MJ8 99 %) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 20 F Summer temperature difference 15 F Total heating load calculation 19016 Btuh Total cooling load calculation 35942 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Strip Heat) 126.2 24000 Sensible (SHR = 0.71) 103.0 25702 529 Btuh Duct loss Latent 95.5 10498 Btuh Subtotal Total sensible gain Total 100.7 36200 WINTER CALCULATIONS Winter Heating Load (for Load component Load Load Window total 365 sqft Window total 365 sqft 7525 Btuh Wall total 1015 sqft 3003 Btuh Door total 46 sqft 419 Btuh Ceiling total 1364 sqft 467 Btuh Floor total See detail report 3615 Btuh Infiltration 24 cfm 529 Btuh Duct loss Btuh 1259 Btuh Subtotal Total sensible gain 16817 Btuh Ventilation 100 cfm 2200 Btuh TOTAL HEAT LOSS Btuh 19016 Btuh Summer Cooling Load (f SUMMER CALCULATIONS Load component Load Window total 365 sqft 10576 Btuh Wall total 1015 sqft 2252 Btuh Door total 46 sqft 629 Btuh Ceiling total 1364 sqft 93 Btuh Floor total 0 Btuh Infiltration 104 cfm 1709 Btuh Internal gain 7150 Btuh Duct gain 890 Btuh Sens. Ventilation 100 cfm 1650 Btuh Blower Load 0 Btuh Total sensible gain 24949 Btuh Latent gain(ducts) 364 Btuh Latent gain(infiltration) 4085 Btuh Latent gain(ventilation) 3943 Btuh Latent gain(intemal/occupants /other) 2600 Btuh Total latent gain 10992 Btuh TOTAL HEAT GAIN 35942 Btuh 8th Edition EnergyGauge® System Sizi PREPARED BY: /h • DATE: 14. 0 t 4l EnergyGauge® / USRFZB v2.8 System Sizing Ca c i ataons - Slimmer Residential Load - Room by Room Component Details Mr James Pann Project Title: 9190 NW 1st Ave Pann Residence Miami Shores, Fl 33150- Reference City: Miami, FL 10/28/2011 Temperature Difference: 15.0F(MJ8 99 %) Humidity difference: 58gr. Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 1 2 1 NFRC 0.29, 1.03 B-L No N 1 NFRC 0.29,1.03 B-L No E Window Total 2.0ft. 2.0ft. 2.0ft. 2.0ft. 29.3 0.0 29.3 25.7 0.0 25.7 55 (sqft) 18 18 18 33 536 Btuh 857 Btuh 1393 Btuh Walls 1 2 3 Type U -Value R -Value Area(sqft) Cav /Sheath Concrete BIk,Hollow- Ext 0.15 4.1/0.1 78.0 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 101.4 Concrete BIk,Hollow - Ext 0.15 4.1/0.1 61.1 Wall Total 240 (sqft) HTM 2.2 2.2 2.2 Load 173 Btuh 225 Btuh 136 Btuh 533 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 1 Unvented Attic/Light/TIIe 0.017 Ceiling Total 30.0/30.0 200.0 200 (sqft) 0.07 14 Btuh 14 Btuh Floors 9 Type Slab On Grade Floor Total R -Value Size HTM 0.0 200 (ft- perimeter) 0.0 200.0 (sqft) Load 0 Btuh 0 Btuh Zone Envelope Subtotal: 1941 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio SensibleNatural 0.70 1650 0.24 CFM= 24.5 Load 405 Btuh Internal gain Occupants Btuh/occupant 0 X 230 + Appliance 900 Load 900 Btuh Sensible Envelope Load: 3245 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 129 Btuh Sensible Zone Load 3374 Btuh Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 3 1 NFRC 029,1.03 B-L No N Window Total 2.0ft. 2.0ft. 6.7 0.0 6.7 7 (sgft) 18 18 122 Btuh 122 Btuh Walls 4 Type U -Value R -Value Area(sqft) HTM Cav /Sheath Concrete BIk,Hollow - Ext 0.15 4.1/0.1 32.2 2.2 Wall Total 32 (sqft) Load 71 Btuh 71 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 2 Unvented Attic/Light/Tile 0.017 30.0/30.0 42.0 0.07 Ceiling Total 42 (sqft) 3 Btuh 3 Btuh EnergyGauge®/ USRFZB v2.8 Page 1 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL MIAMI_INTL AP Pann Residence 10/28/2011 Floors 8 Type R -Value Size HTM Slab On Grade 0.0 42 (ft- perimeter) 0.0 Floor Total 42.0 (sqft) Load 0 Btuh 0 Btuh 3 Zone Envelope Subtotal: 197 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio CFM= SensibleNatural 0.70 347 0.03 3.3 Load 54 Btuh Internal gain Occupants Btuh /occupant Appliance 0 X 230 + 0 Load 0 Btuh Infiltration Sensible Envelope Load: 251 Btuh Duct Toad Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 10 Btuh Sensible Zone Load 261 Btuh Component Loads for Room/Zone Master L Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 3 Unvented Attic/Light/Tile 0.017 30.0/30.0 27.0 0.07 Ceiling Total 27 (sqft) 2 Btuh 2 Btuh Floors 7 Type R -Value Size HTM Slab On Grade 0.0 27 (ft- perimeter) 0.0 Floor Total 27.0 (sqft) Load 0 Btuh 0 Btuh Zone Envelope Subtotal: 2 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio CFM= SensibleNatural 0.70 223 0.00 0.0 Load 0 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 2 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 0 Btuh Sensible Zone Load 2 Btuh EnergyGauge® / USRFZB v2.8 Page 2 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL AP Pann Residence 10/28/2011 Component L oorn /Zon Kitche Window Type* Panes SHGC U InSh IS Omt Overhang Len Hqt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 4 1 NFRC 0.29, 1.03 B-L No N Window Total 2.0ft. 2.0ft. 19.5 0.0 19.5 20 (sqft) 18 18 357 Btuh 357 Btuh Walls 5 Type U -Value R -Value Area(sqft) Cav /Sheath Concrete BIk,Hoilow- Ext 0.15 4.1/0.1 49.9 Wall Total 50 (sqft) HTM 2.2 Load 111 Btuh 111 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 4 Unvented Attic/Light/Tile 0.017 Ceiling Total 30.0/30.0 125.0 125 (sqft) 0.07 9 Btuh 9 Btuh Floors 6 Type R -Value Size HTM Slab On Grade 0.0 125 (ft- perimeter) 0.0 Floor Total 125.0 (sqft) Load 0 Btuh 0 Btuh Wall Total 98 (sqft) Zone Envelope Subtotal: 477 Btuh Infiltration Type ACH SensibleNatural 0.70 Volume(cuft) Wall Ratio 1031 0.05 CFM= 5.1 Load 84 Btuh Internal gain Occupants 1 Btuh/occupant X 230 + Appliance 2000 Load 2230 Btuh Load 6 Sensible Envelope Load: 2791 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 111 Btuh Sensible Zone Load 2902 Btuh Component Load; Room /Zone #9: Luring Roam Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 8 11 1 NFRC 0.29,1.03 B-L No E 1 NFRC 0.29, 1.03 B-L No S 2.0ft. 2.0ft. 2.0ft. 2.0ft. 51.4 0.0 51.4 12.8 12.8 0.0 18 33 18 20 1714 Btuh 235 Btuh Window Total 64 (sqft) 1949 Btuh Walls Type U-Value R -Value Area(sqft) HTM Load Cav /Sheath 6 Concrete BIk,Hollow- at 0.15 4.1/0.1 79.3 2.2 176 Btuh 13 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 19.1 2.2 42 Btuh Wall Total 98 (sqft) 218 Btuh Doors Type Area (sqft) HTM Load 1 Insulated - Exterior 22.8 13.8 314 Btuh Door Total 23 (sqft) 314 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 6 Unvented Attic/Light/Tile 0.017 30.0/30.0 339.0 0.07 23 Btuh Ceiling Total 339 (sqft) 23 Btuh EnergyGauge® / USRFZB v2.8 Page 3 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL AP Pann Residence 10/28/2011 Floors 4 Type R -Value Size HTM Slab On Grade 0.0 339 (ft- perimeter) 0.0 Floor Total 339.0 (sqft) Load 0 Btuh 0 Btuh Window Area(sgft) Gross Shaded Unshaded Zone Envelope Subtotal: 2505 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio CFM= SensibleNatural 0.70 2805 0.10 10.0 Load 166 Btuh Internal gain Occupants Btuh/occupant Appliance 2 X 230 + 900 Load 1360 Btuh Walls 14 15 Sensible Envelope Load: 4031 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 160 Btuh 4191 Btuh Load 16 Btuh 16 Btuh Sensible Zone Load Component Loads for Room /Zone 1O: Family Room Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sgft) Gross Shaded Unshaded HTM Shaded Unshaded Load 13 14 1 NFRC 0.29, 1.03 B -L No W 1 NFRC 0.29, 1.03 B-L No W Window Total 2.0ft. 2.0ft. 2.0ft. 2.0ft. 41.1 0.0 41.1 40.0 0.0 40.0 81 (sqft) 18 33 18 33 1371 Btuh 1334 Btuh 2706 Btuh Walls 14 15 Type U -Value R -Value Area(sqft) HTM Cav /Sheath Concrete BIk,Hollow- Ext 0.15 4.1/0.1 75.8 2.2 Concrete BIk,Hollow - AdJ 0.15 4.1/0.1 83.5 2.2 Wall Total 159 (sqft) Type Area (sqft) HTM Insulated - Garage 22.8 13.8 Door Total 23 (sqft) Load 168 Btuh 185 Btuh 353 Btuh Load 314 Btuh 314 Btuh Doors 2 Ceilings 5 Type /Color /Surface U -Value R -Value Area(sqft) HTM Unvented Attic/Light/Tile 0.017 30.0/30.0 240.0 0.07 Ceiling Total 240 (sqft) Load 16 Btuh 16 Btuh Floors 5 Type R -Value Size HTM Slab On Grade 0.0 240 (ft- perimeter) 0.0 Floor Total 240.0 (sqft) Load 0 Btuh 0 Btuh Zone Envelope Subtotal: 3390 Btuh EnergyGauge® / USRFZB v2.8 Page 4 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL AP Pann Residence 10/28/2011 Infiltration Type ACH SensibleNatural 0.70 Volume(cuft) Wall Ratio CFM= 1980 0.16 16.3 Load 268 Btuh Internal gain Occupants 2 Btuh/occupant Appliance X 230 + 0 Load 460 Btuh 2.0ft. 2.0ft. 2.0ft. 2.0ft. 2.Oft. 2.0ft. 29.3 0.0 29.3 25.7 0.0 25.7 12.8 12.8 0.0 68 (sqft) Sensible Envelope Load: 4118 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) Type U -Value R -Value Area(sqft) Cav /Sheath Concrete BIk,Hollow- Ext 0.15 4.1/0.1 121.4 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 6.3 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 98.3 Wall Total 226 (sqft) Type /Color /Surface U -Value R -Value Area(sqft) (DGM of 0.040) 164 Btuh Ceilings 8 Unvented Attic/Light/rile 0.017 Ceiling Total Sensible Zone Load 4282 Btuh Component Loadsjfor 1 .00mlZone°#11: Bedroom, 2'. Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sgft) Gross Shaded Unshaded HTM Shaded Unshaded Load 5 6 7 1 NFRC 0.29, 1.03 B-L No W 1 NFRC 0.29, 1.03 B-L No E 1 NFRC 029, 1.03 B-L No S Window Total 2.0ft. 2.0ft. 2.0ft. 2.0ft. 2.Oft. 2.0ft. 29.3 0.0 29.3 25.7 0.0 25.7 12.8 12.8 0.0 68 (sqft) 18 18 18 33 33 20 977 Btuh 857 Btuh 235 Btuh 2069 Btuh Walls 7 8 9 Type U -Value R -Value Area(sqft) Cav /Sheath Concrete BIk,Hollow- Ext 0.15 4.1/0.1 121.4 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 6.3 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 98.3 Wall Total 226 (sqft) Type /Color /Surface U -Value R -Value Area(sqft) HTM 2.2 2.2 2.2 HTM Load 269 Btuh 14 Btuh 218 Btuh 501 Btuh Load Ceilings 8 Unvented Attic/Light/rile 0.017 Ceiling Total 30.0/30.0 241.0 241 (sqft) 0.07 17 Btuh 17 Btuh Floors 2 Type Slab On Grade Floor Total R -Value Size HTM 0.0 241 (ft- perimeter) 0.0 241.0 (sqft) Load 0 Btuh 0 Btuh Zone Envelope Subtotal: 2587 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio SensibleNatural 0.70 1988 0.22 CFM= 23.1 Load 380 Btuh Internal gain Occupants Btuh/occupant 0 X 230 + Appliance 900 Load 900 Btuh Sensible Envelope Load: 3867 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 154 Btuh Sensible Zone Load 4021 Btuh EnergyGauge® / USRFZB v2.8 Page 5 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL MIAMI_INTL AP Pann Residence 10/28/2011 Component Loads., Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 12 1 NFRC 029, 1.03 B-L No W Window Total 2.Oft. 2.0ft. 6.7 0.0 6.7 7 (sqft) 18 33 223 Btuh 223 Btuh Walls 12 Type U -Value R -Value Area(sqft) Cav /Sheath Concrete BIk,Hollow- Ext 0.15 4.1/0.1 37.8 Wall Total 38 (sqft) HTM 2.2 Load 84 Btuh 84 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 9 Unvented Attic/Light/Tile 0.017 Ceiling Total 30.0/30.0 70.0 70 (sqft) 0.07 5 Btuh 5 Btuh Floors 1 Type R -Value Size HTM Slab On Grade 0.0 70 (ft- perimeter) 0.0 Floor Total 70.0 (sqft) Load 0 Btuh 0 Btuh Zone Envelope Subtotal: 311 Btuh Infiltration Type ACH SensibleNatural 0.70 Volume(cuft) Wall Ratio 583 0.04 CFM= 3.9 Load 64 Btuh Internal gain Occupants 0 Btuh/occupant X 230 + Appliance 400 Load 400 Btuh Sensible Envelope Load: 775 Btuh Duct load Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 31 Btuh Sensible Zone Load 806 Btuh Componten na fc RoomlZonie . €droo Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 9 10 1 NFRC 0.29, 1.03 B-L No E 1 NFRC 0.29, 1.03 B-L No S Window Total 2.0ft. 2.0ft. 2.0ft. 2.0ft. 38.5 0.0 38.5 25.7 25.7 0.0 64 (sqft) 18 33 18 20 1286 Btuh 470 Btuh 1756 Btuh Walls 10 11 Type U-Value R -Value Area(sqft) HTM Cav /Sheath Concrete BIk,Holiow- Ext 0.15 4.1/0.1 78.1 2.2 Concrete BIk,Hollow- Ext 0.15 4.1/0.1 93.1 2.2 Wall Total 171 (sqft) Load 173 Btuh 206 Btuh 380 Btuh Ceilings Type /Color /Surface U -Value R -Value Area(sqft) HTM Load 7 Unvented Attic/Light/Tile 0.017 30.0/30.0 79.8 0.07 Ceiling Total 80 (sqft) 5 Btuh 5 Btuh Floors 3 Type R -Value Size HTM Slab On Grade 0.0 202 (ft- perimeter) 0.0 Floor Total 202.0 (sqft) Load 0 Btuh 0 Btuh EnergyGauge® / USRFZB v2.8 Page 6 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL AP Pann Residence 10/28/2011 EnergyGauge® / USRFZB v2.8 Page 7 Zone Envelope Subtotal: 2141 Btuh Infiltration Type ACH Volume(cuft) Wall Ratio CFM= SensibleNatural 0.70 1667 0.17 17.5 Load 288 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 900 Load 900 Btuh Sensible Envelope Load: 3329 Btuh Duct Toad Average sealed, Supply(R6.0- Attic), Retum(R6.0- Cond.) (DGM of 0.040) 132 Btuh Sensible Zone Load 3462 Btuh EnergyGauge® / USRFZB v2.8 Page 7 Mr James Pann 9190 NW 1st Ave Miami Shores, Fl 33150- Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL AP Pann Residence 10/28/2011 WHOLE HOUSE TOT4 Whole House Totals for Cooling Sensible Envelope Load All Zones Sensible Duct Load Total Sensible Zone Loads Sensible ventilation Blower Total sensible gain Latent infiltration gain (for 58 gr. humidity difference) Latent ventilation gain Latent duct gain Latent occupant gain (5 people @ 200 Btuh per person) Latent other gain Latent total gain TOTAL GAIN 22410 Btuh 890 Btuh 23300 Btuh 1650 Btuh 0 Btuh 24949 Btuh 4085 Btuh 3943 Btuh 364 Btuh 1000 Btuh 1600 Btuh 10992 Btuh 35942 Btuh EQUIP,,., 1. Central Unit Rheem #14AJM036 36200 Btuh *Key. Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U- Factor) (InSh - Interior shading device: none(No), BlInds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half( .4)) (Omt - compass orientation) Version 8 EnergyGauge® / USRFZB v2.8 Page 8 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Nu -Vue Industries, Inc. 1055 East 29th Street Hialeah, FL 33013 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -290I FAX (305) 372 -6339 www.miamidade.gov/buildinacode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur immediately revoke, modify, or suspend the use of such pro l reserves the right to revoke this acceptance, if it is determin Division that this product or material fails to meet the require —spe This product is approved as described herein, and has been desi Code, including the High Velocity Hurricane Zone. e� expense fch testing and the AHJ may r ma en i; t i'thin their jurisdiction. BORA by is - ade County Product Control oft e applicable building code. with the Florida Building DESCRIPTION: Series AB, NVSTA, NVHTA, NV`'„ 1, , an NVHC -37 Wood Connectors APPROVAL DOCUMENT: Drawing No. NU -1, titled' Truss and `Thp Plate Anchors ", sheets 1 through 4 of 4, dated 02/18/08, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA # 03-0224.10 and consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. APPROVED qir 6/13frt? NOA No. 08- 0325.02 Expiration Date: May 22, 2013 Approval Date: June 5, 2008 Page 1 Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMI'1"1'ED A. DRAWINGS 1. Drawing No. NU 1, titled "Truss and Top Plate Anchors ", sheets 1 through 4 of 4, dated 02/18/08, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E. B. TESTS Test reports on wood connectors per ASTM D1761-88 by Product Testing, Inc., signed and sealed by C. R. Caudel, P.E. Report No. Wood Connector 1. 05 -5195A AB -5 2. 05 -5196A AB -7 3. 04 -4995 NVTHJ -26 4. 04 -4996 NVTHJ -28 5. 05 -5612 IKE -1 6. 06 -5622 IKE -2 7. 04 -4908 NVTT 8. 03 -4631 NVTT 9. 08 -6711 NVHC -37 Load Direction F1 and F2 F1 and F2 Upward Upward Upward, L1 and L2 Upward, L1 and L2 Upward and Ll Upward and L1 Upward, Ll and L2 Date 06/03/05 06/11/05 01/31/05 01/31/05 03/20/06 05/01/06 07/21/04 06/21/04 03/14/08 C. CALCULATIONS 1. Shear value of common wire nails and steel plate tensile calculations, prepared by Vipin N. Tolat, P.E., Consulting Engineer, dated 03/20/08, signed and sealed by Vipin N. Tolat, P.E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Code conformance letters, issued by Product Testing, Inc., signed and sealed by C. R. Caudel, P.E. G. OTHER 1. Notice of Acceptance No. 03- 0224.10, issued to Nu -Vue Industries, Inc., approved on 04/17/03 and expiring on 05/22/08. Ca os Utrera, P.E. Product Control Examiner NOA No. 08-0325.02 Expiration Date: May 22, 2013 Approval Date: June 5, 2008 E -1 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) PGT Industries 1070 Technology Drive Nokomis, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has beers reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material" within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "FD -650" Outswing Aluminum French Door w/Sidelites — N.I. APPROVAL DOCUMENT: Drawing No. 8000 -12, titled "Alum. French Door & Side Lites, Non - Impact", sheets 1 through 11 of 11, dated 12/30/04, with revision C dated 01/25/10, prepared by the manufacturer, signed and sealed by Robert L. Clark, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None. LIMITATIONS: Miami Dade County Product Control Approved Shutters Or Protection Devices Shall Be Required. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section.of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA # 07- 0103.01 and consists of this page 1 and evidence pages E -1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.miamidade.uov/buildins;code MAMI DADE COUNTY APPROVED NOA No. 09- 1028.09 Expiration Date: March 24, 2015 Approval Date: February 10, 2010 Page 1 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No 8000 -12, Sheets 1 through 11 of 11, titled "Alum. French Door & Side Lites, Non - Impact", dated 12/30 /04 with revision C dated 01/25/10, prepared by manufacturer, signed and sealed by Lucas A. Turner, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94, 5) Cyclic Wiiid Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, Per FBC 2411 3.2.1 and TAS 202 -94 along with marked -up drawings and installation diagram of aluminum doors of OXXO configuration, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -4921, dated 07/17/06, signed and sealed by Edmundo Largaespada, P. E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Forced Entry Test, Per FBC 2411 3.2.1 and TAS 202 -94 along with marked -up drawings and installation diagram of aluminum doors of XXXO configuration, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -4450, dated 12/14/04, signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA #05- 0107.01) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Forced Entry Test, Per FBC 2411 3.2.1 and TAS 202 -94 along with marked -up drawings and installation diagram of aluminum doors of OXXX configuration, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL- 4451, dated 12/14/04, signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA #05- 0107.01) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Forced Entry Test, Per FBC 2411 3.2.1 and TAS 202 -94 along with marked -up drawings and installation diagram of aluminum doors of XXXO configuration, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL -4452, dated 12/14/04, signed and sealed by Edmundo Largaesp . E. (Submitted under previous NOA #05- 0107.01) E -1 anuel ' = ez ` .E. Product Contr ner NOA No. ! ' - ' 28.09 Expiration Date: March 24, 2015 Approval Date: February 10, 2010 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test, 2) Uniform Static Air Pressure Test, 3) Water Resistance Test, 4) Forced Entry Test, per SFBC 3603.2 (b) along with marked -up drawings and installation diagram of an aluminum sliding glass door using a low sill threshold, glazed with 3/16" temp. glass, prepared by Fenestration Testing Laboratory, Inc., Test Report Na. FTL -5967, dated 05/07/09, signed and sealed by Julio E. Gonzalez, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2007, dated 10/01/09, prepared, signed and sealed by Robert L. Clark, P.E. Complies with ASTM E1300 -02/04 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance, dated October 22, 2009, signed and sealed by Robert L. Clark, P.E. 2. Statement letter of no financial interest, dated October 22, 2009, signed and sealed by Robert L. Clark, P.E. 3. Laboratory compliance letter for Test Report No. FTL- 4921, issued by Fenestration Testing Laboratory, Inc., dated June 26, 2006, signed and sealed by Edmundo Largaespada, P.E. 4. Proposal No. 08 -1891 issued by BCCO, dated January 26, 2009, signed by Ishaq Chanda, P.E. G. OTHER 1. Notice of Acceptance No. 07- 0103.01, issued to POT Industries for their Series FD- 650 Aluminum French Door w /Sidelites, approved on 03/15/07 and expiring on 03/24/10. E -2 Manuel Per Product Control NOA No. 09 ! ; .09 Expiration Date: March 24, 2015 Approval Date: February 10, 2010 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/buildingcode Nu -Vue Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCPRC reserves the right to revoke this acceptance, if it is determined by Miami -Dade county Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series NVTA, NVTAS, NVBH, NVUH, NVRT and NVTH Wood Connectors. APPROVAL DOCUMENT: Drawing No. NU -2, sheets 1 through 4, titled "NVTA and NVTAS, NVBH 24 and NVUH, NVRT and NVTH', dated 02/13/03, with last revision on 07/19/06, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance (NOA) number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 05- 0701.04 and consists of this page 1 and evidence pages El and E2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No: 08-0326.11 Expiration Date: August 21, 2013 Approval Date: May 22, 2008 Page 1 Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. NU -2, sheets 1 through 4, titled "NVTA and NVTAS, NVBH 24 and NVUH, NVRT and NVTH", dated 02/13/03 with last revision on 07/19/06, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E. "Submitted under NOA No. 05- 0701.04" B. TEST Test reports on wood connectors per ASTM D1761 by Product Testing, Inc., signed and sealed by C. R. Caudel, P.E. and S. E. Black, P.E. Report No. Wood Connector Direction Date 1. PT 02 -4073 NVTA Upward 11/06/02 2. PT 02 -4075 NVTA Upward 11/07/02 3. PT 02 -4074 NVTA Upward 11/06/02 4. PT 02 -3938 NVTA Upward 08/06/02 5. PT 03 -4177 NVRT36 Upward 02/03/03 6. PT 03 -4202 NVRT36 -T Upward 02/19/03 7. PT 03 -4271 NVRT36 -T Upward 03/27/03 8. PT 03 -4270 NVRT24 -T Upward 03/27/03 9. PT 02 -4095 NVUH26 Up & Downward 01/17/03 10. PT 02 -4096 NVBH24 Up &Downward 12/03/02 11. 31- 22456.0002 NVTA & NVTAS Lateral 07/06/02 12. PT 04 -4698 NVTH24 Upward Parallel/Perpendicular 04/15/04 13. PT 04 -5036 NVTH24 Upward Load 12/10/04 C. CALCULATIONS Report of Design Capacities prepared by V. Product Model No. of Paces 1. NVBM24 7 through 8 2. NVRT 9 through 14 3. NVTA & NVTAS 1 through 6 4. NVTA & NVTAS 1 through 14 5. NVRT 15 through 15 "Submitted under NOA No. 04- 1202.01" N. Tolat, P.E. Date Signature 05/05/03 V. N. Tolat, P.E 05/05/03 V. N. Tolat, P.E. 05/05/03 V. N. Tolat, P.E. 02/06/03 V. N. Tolat, P.E. 07/07/03 V. N. Tolat, P.E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). 1 52,p arlos M. IItiera P.E. Product Control Examiner NOA No: 08-0326.11 Expiration Date: August 21, 2013 Approval Date: May 22, 2008 E -1 Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED EMATERIAL CERTIFICATIONS E. STATEMENTS 1. No Financial Interest and code compliance letter issued by Vipin N. Tolat, P.E., on 03/26/03 signed and sealed by V. N. Tolat, P.E. "Submitted under NOA No. 04-1202.01" 2. Letter to Nu -Vue Industries issued by Building Code Compliance Office on 08/10/04 and signed by C. F. Font, P.E. "Submitted under NOA No. 04-1202.01" G. OTHER 1. Notice of Acceptance No. 08- 0326.11, issued to Nu -Vue Industries, Inc., approved on 09/14/06 and expiring on 08/21/08. E -2 eg Carlos M. Utrera, P.E. Product Control Examiner NOA No: 08-0326.11 Expiration Date: August 21, 2013 Approval Date: May 22, 2008 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 NOTICE OF ACCEPTANCE (NOA) www.maimidade.Rov/buildinecode, Nu -Vue Industries, Inc. 1055 E. 29 Street Hialeah, Florida 33013 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miaini Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the. Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series NVJH, NVTP/H, NVSO and NVHC Wood Connectors. APPROVAL DOCUMENT: Drawing No. NU -3, titled "NVJH Joist Supports, NVTP & NVTPH Plate Anchors, NVSO 236 Joist Hanger, NVHC 43 & NVHC 43/2 Hurricane Clip ", sheets 1 through 3 of 3, dated 07/10/03, with last revision # 3 dated 04/27/05, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E., bearing the Miami Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA hall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 05- 0516.01 and consists of this page 1 and evidence page E -1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 08- 0828.02 Expiration Date: January 1, 2014 Approval Date: October 23, 2008 Page 1 11 �1 Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. NU -3, titled "NVJH Joist Supports, NVTP & NVTPH Plate Anchors, NVSO 236 Joist Hanger, NVHC 43 & NVHC 43/2 Hurricane Clip ", sheets 1 through 3 of 3, dated 07/10/03, with last revision # 3 dated 04 /27/05, prepared by Nu -Vue Industries, Inc., signed and sealed by Vipin N. Tolat, P.E. "Submitted under NOA # 05-0516.01" B. TESTS Test reports on wood connectors per ASTM D and sealed b.y C. R. Caudel, P.E. Report No. Wood Connector 1. PT # 03 -4303 NVTP4 2. PT # 03 -4343 NVTP4H 3. PT # 03 -4344 NVTP4 4. PT # 03 -4345 NVTP4H 5. PT # 03 -4349 NVS0236 6. PT # 03 -4357 NVS0236 7. PT # 03 -4358 NVJH24 8. PT # 03 -4385 NVJH26 9. PT # 03 -4386 NVS0236 10. PT # 03 -4387 NVJH28 "Submitted under NOA # 03- 0730.03" 1761 by Product Testing, Inc., signed Direction Upward Upward Upward Upward Up & Down Up & Down Up & Down Up & Down Up & Down Up & Down Date 04/21/03 05/05/03 05/01/03 05/02/03 05/19/03 05/20/03 05/30/03 05/30/03 05/13/03 05/30/03 C. CALCULATIONS 1. Report of Design Capacities, dated 07/22/03, sheets 1 through 13 of 13, prepared, signed and sealed by Vipin N. Tolat, P.E. "Submitted under NOA # 03- 0730.03" 2. Report of Design Capacities, dated 0713 /05, sheets 1 through 5 of 5, prepared, signed and sealed by Vipin N. Tolat, P.E. "Submitted under NOA # 05- 0516.01" D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E -1 JpM Carlos M. Utrera, P.E. roduct Control Examiner NOA No. 08- 0828.02 Expiration Date: January 1, 2014 Approval Date: October 23, 2008 Nu -Vue Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Statement letter of code conformance, no financial interest and no change of product, dated 08/21/08, issued, signed and sealed by Vipin N. Tolat, P.E. G. OTHER 1. Notice of Acceptance No. 05- 0516.01, issued to Nu -Vue Industries, Inc., approved on 09/29/05 and expiring on 01/01/09. olz-h? Carlos M. Utrera, P.E. oduct Control Examiner NOA No. 08- 0828.02 Expiration Date: January 1, 2014 Approval Date: October 23, 2008 E -2 MIAMI E COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Jeld -Wen, Inc. 31725 Highway 97 North Chiloquin, OR 97624 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: The Jeld -Wen Series "Alum Clad" — Outswing Wood French Doors APPROVAL DOCUMENT: Drawing No. JWC0032, titled "Aluminum Clad Wood Outswing French Door" Sheets 1 through 8 of 8, prepared by manufacture dated 06/21/06 and last revised on 06-27 -2007, signed and sealed by Eric S. Nielsen, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: ".Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official This NOA revises NOA # 07- 0205.02 (# 06- 0719.06) and consists of this page 1 and evidence pages E -1, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P. E. MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.buildingcodeonline.com v q // NOA No 07- 0314.01 Expiration Date: February 11, 2012 Approval Date: July 26, 2007 Page 1 ,Teld -Wen. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS (transferred from files # 07- 0205.02) 1. Manufacturer's die drawings and sections. 2. Drawing No. JWC0032, titled "Aluminum Clad Wood Outswing French Door" Sheets 1 through 8 of 8, prepared by manufacture dated 06/21/06 and last revised on 06 -27 -2007, signed and sealed by Eric S. Nielsen, P.E. B. TESTS (transferred from files # 06- 0719.06 (# 03- 0224.06)) 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1 (b) and TAS 202 -94 Along with marked -up drawings and installation diagram of outswing wood French doors, prepared by Architectural Testing Lab, Test Report No. 61976.01- 301 -18 dated 03- 24 -06, signed and sealed by Joseph A. Reed, P.E and 03- 31369.01 dated 03 -15 -02 & 03- 31369.02 dated July 22,2000, signed and sealed by Steven M. Urich, P.E C. CALCULATIONS (transferred from files # 07- 0205.02) 1. Anchor verification calculations complying w/ FBC 2004, dated 03/01/07, prepared by PTC, signed & sealed by Eric S. Nielsen, P.E. 2. Anchor verification calculations complying w/ FBC 2004, dated 9/12/06 and last revised on 09 -14-06, prepared, signed & sealed by L. Roberto Lomas, P.E.(transferred from files # 07- 0205.02) D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 06- 1205.01 issued to E.I. DuPont DeNemours for their "Sentry Glass Plus ®" expiring on 01/14/2008. F. STATEMENTS (transferred from files # 07- 0205.02) 1. Statement letter of conformance & no financial interest, dated 03/01/07, signed by Eric S. Nielsen, P.E. 2. Statement letter of conformance & no financial interest, dated 07/13/06, signed by L. Roberto Lomas, P.E. 3. Lab compliance statement as part of above test reports. G. OTHER . 1. This NOA revises NOA No. 07- 0205.02 (# 06- 0719.06), issued to Jeld -Wen, which was originally issued under NOA # 03 -0224.06 to Pozzi Window Company for Aluminum Clad Wood Outswing Door, expiring on 2/11/07. 2. Letter of acquisition of Pozzi Window by 7eld -Wen Inc., dated July 06, 2006, signed by David G. Stork (Jeld -Wen Inc.) E -1 Isk4 t. 01.4.41, gI.Chanda,P.E. Product Control Examiner NOA No 07- 0314.01 Expiration Date: February 11, 2012 Approval Date: July 26, 2007 18 Gauge Angle Clips. AB -7 AB-5 Typical Installation Product Code Dimensions (inches) Fastener Schedule Alowable Loads (lbs) Wl W2 L Header Joist Fl F2 AB5 14 25X6 5 3- l0dxl5X" 3- 10dx1Y2" 511 595 AB7 1X 25X6 7 4-10dx134" 4- 10dx1W" 582 794 Notes: Nail wider angle leg to Joist and Shorter leg to Header. GENERAL NOTES: 1. Steel shall conform to ASTM A653, structural grade 33 (Min. yield 33 ksi) and aminimum galvanized coating of G 60 per ASTM A525. 2. Allowable loads are based on National Desing specifications (NDS) for wood construction, 2001/2005 Edition. 3. Design loads are for Southern Pine species with a specific gravity of 0.55. Allowable loads for other species shall be adjusted accordingly. 4. Common wire nail values are based on NDS table 11P, G=0.55 and have been reduced for Penetration Depth factor P /10D. 5. Allowable loads for wind uplift have already been increased by a duration factor of 60% for anchor nail. Load values shown are without 33% steel stress increase. 6. Allowable loads for more than a single connection cannot be added together. A design load which is divided into components in the direction given must be evaluated as follows: Actual Uplift + Actual Ll + Actual L2 < -1.0 Allowable Uplift Allowable Ll Allowable L2 7. Allowable loads are based on 132" thick wood members unless otherwise noted. 8. All tie beams and grouted concrete masonry shall comply with chapter 21 of FBC. Concrete for tie beams and grout and mortar for concrete masonry shall be a minimum of 2500 psi. Concrete masonry shall comply with ASTM C90. 9. All tests have been conducted in accordance with ASTM D -1761. VIPIN N. TOLAT, PE (CIVIL) FL REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 PRODUCT REVISED as complying watts flodia Mang Cello AcceptanceNo0, 3 -. Cr!i" Pro Matra! Nu —Vue Industries, �. 1053 -1059 East 29 Street Hialeah, Florida 33013 (305) 694 -0397 Fax: (305) 694 -0398 TRUSS AND TOP PLATE ANCHORS DWG #: NU -1 Sheet 1 of 4 Date: Feb 18, 2,008 Revisions: Deep Seat Truss Anchor.. They are designed to resist lateral and uplift forces. The strap is made of 14 gauge steel and the seats of 20 gauge steel. UPLIFT Assembly Product Code Dimension H (inches) Total No. of Fasteners in Strap 10d x 13" Total No. of Fasteners in 20 GA. Seat 10d x 1%" Allowable Loads (lbs) U lift 6 p Ll 6 L2 6 NVSTAI2 12 5 6 1046 700 1049 6 6 1141 760 1144 NVSTA16 16 7 6 1236 823 1239 NVSTA20 20 8 6 1331 887 1335 9 6 1426 950 1430 NVSTA22 22 2259 NVSTA24 24 Holden Double Strap Riveted Truss Anchor.. They are designed of 14 gauge steel plates to resist lateral and uplift forces. The seats are made of 20 gauge steil 1" UPLIFT Assembly Product Code Dimension H (inches) Total No. of Fasteners in two Straps 10d x 1i" Total No. of Fasteners in 20 GA. Seat 10d x 1 %" Allowable Loads (lbs) 6 Uplift 5 Uplift Li L2 NVHTA12 12 10 6 1506 1766 1050 1450 12 6 1695 1987 1181 1631 NVHTA16 16 14 6 1883 2208 1312 1812 NVHTA20 20 16 6 2071 2429 1444 1994 18 6 2259 2649 1575 2175 NVHTA22 22 Notes: PRODU CT 1. Nails are necessary in straps and seat to achieve, desing 1oat "? veld 2. See note 6, sheet 1 for combined loading. Acceptance No Q, ExtirittinallgteA NVHTA24 24 . 4. For general notes, see sheet 1. 5. For higher uplift loads, concrete shall be 3000 psi. 6. Based on min. 2500 psi concrete. VIPIN N. TOLAT, PE (CIVIL) FL REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 the Re Nu —Vue modes, inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 (305) 694-0397 Fax: (305) 694 -0398 TRUSS AND TOP PLATE ANCHORS DWG #: NU -1 Sheet 2 of Date: Feb 18, 2,008 Revisions: 12 Gauge NVTHJ Truss Hip & Jack Hanger NVTHJ -26 as shown NVTHJ -28 similar U.S Patent No. 4,964,253 c Jack 1 -2x 20G Stud Plate Ties IKE -1 ( ISOMETRIC) l Typ, Produce} Code Allowable Loads (lbs) S. Pine Nail Schedule Loads Header Nails 16d (e) Hip Nail 10d Jack Nail 10d a b total c d total 1% 1478 16 4 3 7 2 3 5 NVT HJ26 NVTHJ28 1931 20 5 4 9 2 3 5 NVTHJ -28 as shown NVTHJ -26 similar Note: For 1 -2x members 10dx1Y" nails can be used IKE -1 UPLIFT IKE -2 TYPICAL IKE1 INSTALATION Product Code Dimensions (inches) Fasteners Allowable Loads (lbs) W A L Stud Plate Uplift Ll L2 IKE 1 1% 5 3% 6-10d 4-10d 787 337 337 IKE 2 1% 653 3% 6-10d 7 -10d 932 451 318 PRODUCT REVISED es complying wads) Florida Banding Code Acceptance No / :-O Elm► ►,:. . IFF,1 By Division VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX .77068 Product Control Nu -Vue Industries, Inc. 1053 -1059 Ease. 29 Street Hialeah, Florida 33013 (305) 694-0397 Fax: (305) 694-0398 TRUSS AND TOP PLATE ANCHORS DWG #. NU -1 Sheet: 3 of 4 Date: Feb 18, 2,008 Revisions: 18 Gauge NVTT Sanibel Truss Strap Product Code Dimensions (mches) Fasteners Schedule Allowable Loads (lbs) W B H L Truss Top Plates Ho Uplift Li NVTT 1 146 1% 14 13 2- 10dx1W" 6-10d ---- 968 543 116 1% 14 13 2- lOdx1W 6-T " 1584 465 NV1T -2 --- 1. 1- 10dx13" nail is placed on each side of the Truss and 3- 10dnails in each leg are placed in two top plates. 2. 3 - 1 / 4 " d i a . x 1 " long, we ant ins are placed in each leg and into the hollow concrete masonry. Maintain Sr edge distance from top of the block and spacing of 3" between tapccms• NVIT 1 and; UPLIFT NVTT 1 As Shown NVT7 -2 Similar except commas masonry with ands instead of Wood Plates sad nails. 18 Gauge NVHC 37 SWAY Grip Clip (520) 1' 4 UPLIFT VIPIN N. TOLAT. PE (CIVIL) FL REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 L4 PRODUCT REVISED B comPlYies wick the Maids ilding Code Maven= No ` R 1 .02 Espirieion a �.,1 i+; 'ls' ProduetCcetrol Nu -Vue Ines, Ina. 1053 -1059 East 29 Street Hialeah, Florida 33013 (305) 694-0397 Fax: (305) 694 -0398 TRUSS AND TOP PLATE ANCHORS DWG #: NU -1 Sheet: 4 of 4 Date: Feb 18, 2,008 Revisions: Nail Schedule Allowable Design Loads (lbs) Product Code won ar Header Plate ar S Joiind st Uplift Li L2 NVHC 37 5 Way Clip y C .p 16-8d or 16-10d 12-8d or mad 702 60 637 UPLIFT VIPIN N. TOLAT. PE (CIVIL) FL REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 L4 PRODUCT REVISED B comPlYies wick the Maids ilding Code Maven= No ` R 1 .02 Espirieion a �.,1 i+; 'ls' ProduetCcetrol Nu -Vue Ines, Ina. 1053 -1059 East 29 Street Hialeah, Florida 33013 (305) 694-0397 Fax: (305) 694 -0398 TRUSS AND TOP PLATE ANCHORS DWG #: NU -1 Sheet: 4 of 4 Date: Feb 18, 2,008 Revisions: GENERAL NOTES: OUTSWING NON-IMPACT FRENCH DOOR(S) AND SIDE LITE (S). 1. GLAZING OPTIONS: A 3/16" TEMPERED GLASS B. 7/8" I.G. GLASS CONSISTING OF (2) LITES OF 3/16" TEMPERED GLASS WITH A 1/2" AIR SPACE. 2. DESIGN PRESSURES: (SEE TABLES 1, 2 AND 3, SHEET 2) AA. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300 -02. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300 -02. 3. CONFIGURATIONS: xis XX, XO, OX, XXX, XXO, OXX, OXO, XX,,, XX, XXXO, O�XXX, OR OXXO WHERE 0 REPRESENTS EITHER THE NARROW JAMB OR FULL JAMB SIDE LITE. AMY TWO ADJACENT X UNITS CAN BE EITHER TWO SINGLE X DOORS OR A DOUBLE XL( DOOR, BOTH USING EITHER THE STANDARD OR THE LOW -RISE SILL. THE FRENCH DOOR ASSEMBLY BEAM IS USED TO ASSEMBLE X, XX, AND O UNITS TO MAKE THE ABOVE CONFIGURATIONS. 4. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. FOR ANCHORAGE REQUIREMENTS SEE SHEETS 8 THROUGH 10. 5. SHUTTERS ARE REQUIRED WHERE IMPACT RESISTANCE REQUIRED. SHUTTERS MUST BE MIAMI -DADE COUNTY APPROVED FOR INSTALLATION IN MIAMI -DADE COUNTY. 6. SEALANTS: INSTALLATION SCREWS, FRAME AND PANEL CORNERS SEALED WITH CLEAR COLORED SEALANT. VERTICAL ASSEMBLY BEAM SEAMS SEALED ON THE INTERIOR AND EXTERIOR WITH CONTRACTOR SEALANT. 7 REFERENCES: TEST REPORTS FTL -4450, FTL -4451, FTL -4452, FTL -4921 AND FTL -5967. ANSI /AF&PA NDS -2005 FOR WOOD CONSTRUCTION ADM -2005 ALUMINUM DESIGN MANUAL 8. THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). r_ 3/16" TEMPERED GLASS EXTERIOR Op Dela F.K 1w10/09 Rendis Plead J.R. Dow R/G 5/8" GLASS BITE t ---41 OR 5,A Oft 009 ban 01/25/10 GLAZING DETAIL MONOLITHIC GLASS SETTING BLOCK Roviolow REVISE ANCHORAGE, ADD SWUM AND ALTERNATE TOP& BO 7OMR.4IL. A REVISE NOTES IL 4 AND 7,ADD NOTE S. UPDATED BUILDING CODE AICODESIGN MANUAL YEARS ADDED TEST REPORT. : 0 fievisionW 0 7/8" NOM. 3/16" TEMPERED GLASS ---'- 1/2" AIR SPACE 3/16" TEMPERED GLASS 5/8" GLASS BITE EXTERIOR +41 OR 53e GLAZING DETAIL I.G. GLASS SETTING BLOCK NOA DRAWING MAP TOPIC SHEET GENERAL NOTES 1 CONFIGURATIONS 1 GLAZING DETAILS 1 DESIGN PRESSURES 2 ELEVATIONS 3 VERT. SECTIONS 4 HORIZ. SECTIONS 5 PARTS LIST 6 EXTRUSIONS 7 -8 ANCHORAGE 9 -11 PRODUCT REVARD eatuptring mob. IRtaskIP Baran Cog, ERpirsitten NO CHANGES THIS won: Date: �� Dab: 1070 TECHNOLOGY DRIVE NOKOMIS, FL 34275 P.O. BQX 1529 NOKOMIS, FL 34274 GENERAL NOTES, GLAZING DETAILS AND MAP ALUM. FRENCH DOOR & SIDE LITES, NON- IMPACT FULL a� a 11 8000-12 C Robert L. Clark, P.E. PE #39712 Structural TABLE 1. COMPARATIVE ANALYSIS: OUTSWING DOORS GLASS A. 3/16" TEMPERED GLASS zOPTIONS: B. 7/8" I.G. (3116 "T, AIR SPACE, 3 /16 "T) 8 DOOR WIDTH 20 25" DOOR HEIGHT TABLE 3. COMPARATIVE ANALYSIS: NARROW JAMB SIDE LITE GLASS A. TEMPERED GLASS OPTIONS: B. 7/8" I.G. (3/16"T, AIR SPACE, 3/16 9') 68 - 79 3/4" +100.0 -145.0 70- 833/4" +100.0 -145.0 87 3/4" +100.0 -145.0 91 3/4" +100.0 -145.0 80- 953/4" +100.0 - 139.5 SIDE LITE WIDTH SIDE LITE HEIGHT 6 "- 793/4" 7 "- 833/4" 87 3/4" 91 314" 80- 983/4" 10 11/16" +100.0 -145.0 100.0 -145.0 +100.0 -145.0 100.0 -145.0 +100.0 -145.0 X 27" +100.0 -145.0 +100.0 -145.0 +100.0 -144.2 +100.0 -136.9 +100.0 -130.3 13 11/16" +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 100.0 -145.0 +100.0 -145.0 X 29" +100.0 -145.0 +100.0 -143.4 +100.0 -135.7 +100.0 -128.7 +100.0 -122.4 16 11116" +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 X 26 31" +100.0 -144.2 +100.0 -135.8 +100.0 -128.3 +100.0 -121.6 +100.0 -116.6 19 11/16" +100.0 -145.0 100.0 -145.0 +100.0 -145.0 100.0 -145.0 +100.0 -145.0 X 28 33" +100.0 -126.7 +100.0 -126.7 X 36" +100:0 -112.2 +100.0 -112.2 +100.0 -122.0 +100.0 -115.5 +100.0 -109.7 21 11/16" +100.0 -145.0 +100.0 -145.0 100.0 -145.0 100.0 -145.0 +100.0 -145.0 +100.0 -112.2 +100.0 -110.2 +100.0 -104.6 2411116" +100.0 -145.0 100.0 -145.0 +100.0 -145.0 100.0 -144.9 +100.0 -137.9 X 30 37I +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 3011116" +100.0 -142.9 +100.0 -135.3 +100.0 -127.8 +100.0 -121.1 +100.0 -115.1 XX 40 47 3/4" +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 +100.0 -139.5 33 11116" +100.0 -118.6 +100.0 -118.6 +100.0 -118.6 +100.0 -112.5 +100,0 -106.8 XX 51 3 /4" +100.0 -145.0 +100.0 -145.0 +100.0 -144.2 +100.0 -136.9 +100.0 -130.3 36 11/16" 100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 xx 56 3/4" +100.0 -145.0 +100.0 -143.4 +100.0 -135.7 +100.0 -128.7 +100.0 -122.4 XX 50 69 3/4" +100.0 -144.2 XX 54 63 3/4" +100.0 -126.7 +100.0 -135.8 +100.0 -128.3 +100.0 -121.6 +100.0 -115.6 +100.0 -126.7 +100.0 -122.0 +100.0 -115.6 +100.0 -109.7 XX 673/4" +100.0 -112.2 +100.0 -112.2 +100.0 -112.2 +100.0 -110.2 +100.0 -104.6 XX 60 71 314" +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 TABLE 2. COMPARATIVE ANALYSIS: FULL JAMB SIDE LITE GLASS A. 3/16" TEMPERED GLASS OPTIONS: C. 7/8" I.G. (3/16 "T, AIR SPACE, 31161) SIDE LITE WIDTH SIDE LITE HEIGHT 60 - 79 3/4" 70 - 83 3/4" 87 3/4" 91 _ 3/4" 80.95 3/4" 21 11/16" +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 +1000 -145.0 +100.0 -145.0 2411/16" +100.0 -145.0 +100.0 -145.0 +100.0 -145.0 +100.0 -144.9 +100.0 -137.9 3011/16" +100.0 -142.9 +100.0 -135.3 +100.0 -127.8 +100.0 -121.1 +100.0 -115.1 3311/16" +100.0 -118.6 +100.0 -118.6 +100.0 -118.6 +100.0 -112.5 +100.0 -106.8 3611/16" +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 +100.0 -100.0 NOTE: REFERENCE TEST REPORTS FTL4450, FTL -4451, FTL -4452, FTL -4921 AND FTL 5987. A 1 OVERHANG HEIGHT L A NOTES: 1. IF USING THE OPTIONAL LOW-RISE SILL (PART 10, SHEET 7 OF 11), THE OVERHANG HEIGHT MUST BE GREATER THAN THE OVERHANG LENGTH (SEE DIAGRAM). IF NOT, THE MAXIMUM POSITIVE ( +) DESIGN PRESSURE IS LIMITED TO +50.0 PSF FOR ALL STYLES AND SIZES OF THE DOOR AND ANY ADJOINING SIDELITES. OVERHANG k"' LENGTH O PRODUCT REVSSED cs/raptyhag,iIthi 1s Wert& DukReg Aoseptesoe g - ► ,6 o" 5 Rowdily!: Rerteras: F.K 10/10Oe A ADD 7ESTREPORT NO CHANGE TO TABLE& Reved AR. Roved* Dodo: CORR Rode e= B ADDED NOTE/DIAGRAM FOR LOW SILL OPTIOAL ADDED TEST REPORTS F.K. Aare: 01!75/10 12!30/04 O cheaedsr NO CHANGES THIS SHEET. Dade: 1070 TECHNOLOGY DRIVE NOKOMIS, FL 34276 P.O. BQX 1620 NOKOMIS, FL 34274 DESIGN PRESSURES ALUM. FRENCH DOOR & SIDE LITES, NON - IMPACT eadeoh/od@: NA Sheet 2 ar11 8000 -12 C Robert L. Clark, P.E. PE #39112 Structural 95 HE 79 1/8" MAX. DLO ALL OX OR XO 37' MAX. WIDTH 12-5" MAX DLO ALL X UNITS X 110 5/8" MAX. WIDTH 113l4" MAX, WIDTH OXO XX NOTES: 1. CONFIGURATIONS WITH SIDE LITES CAN BE EITHER NARROW JAMB OR FULL JAMB VERSIONS. 2. FOR ANCHOR SPACING AND DETAILS, SEE SHEETS 8 THROUGH 10. 3. FOR VERTICAL SECTIONS SEE SHEET 4 AND FOR HORIZONTAL SECTIONS SEE SHEET 5. 145 3/8" MAX. WIDTH 36 11/16" MAX. WIDTH 26" MAX. DLO 0XXO (SHOWING EACH VERSION SIDELITE) 3611/16" MAX. WIDTH 33 3/16" MAX. DLO 0 (FULL JAMB) 0 (NARROW JAMB) pRoDucr REVISED eomPlYing WItb.t a Roddy Belding Code ee/mce No. Ssplrmtiaa Date RIG J.R. Reveal Is Reedee AR. Own Ejv Rl. Deft 10115/0@ Aft 0 01/25/10 X0 /04 A NO CHANGE MS SHEET HovNionw 6 NO CHANGE THIS SHEET Keehn°/». NOMINEES THIS SHEET. c t heekeaBy oez 1070TECHNOLOOYDRIVE NOKOMIS. FL 34276 P.O. SOX 1620 NOKOMIS. FL 34274 EXAMPLE ELEVATIONS tee ALUM. FRENCH DOOR & SIDE LITES, NON - IMPACT F0050 NTS 3 er11 ennoviva 8000-12 .l Robert L. Clark. P.E. PE #39712 Structural 73 13/16" MAX. WIDTH —1 1 3/4" IGHT kli A 1 - e � / // , "lei \ 79 1/8" MAX. DLO ALL OX OR XO 37' MAX. WIDTH 12-5" MAX DLO ALL X UNITS X 110 5/8" MAX. WIDTH 113l4" MAX, WIDTH OXO XX NOTES: 1. CONFIGURATIONS WITH SIDE LITES CAN BE EITHER NARROW JAMB OR FULL JAMB VERSIONS. 2. FOR ANCHOR SPACING AND DETAILS, SEE SHEETS 8 THROUGH 10. 3. FOR VERTICAL SECTIONS SEE SHEET 4 AND FOR HORIZONTAL SECTIONS SEE SHEET 5. 145 3/8" MAX. WIDTH 36 11/16" MAX. WIDTH 26" MAX. DLO 0XXO (SHOWING EACH VERSION SIDELITE) 3611/16" MAX. WIDTH 33 3/16" MAX. DLO 0 (FULL JAMB) 0 (NARROW JAMB) pRoDucr REVISED eomPlYing WItb.t a Roddy Belding Code ee/mce No. Ssplrmtiaa Date RIG J.R. Reveal Is Reedee AR. Own Ejv Rl. Deft 10115/0@ Aft 0 01/25/10 X0 /04 A NO CHANGE MS SHEET HovNionw 6 NO CHANGE THIS SHEET Keehn°/». NOMINEES THIS SHEET. c t heekeaBy oez 1070TECHNOLOOYDRIVE NOKOMIS. FL 34276 P.O. SOX 1620 NOKOMIS. FL 34274 EXAMPLE ELEVATIONS tee ALUM. FRENCH DOOR & SIDE LITES, NON - IMPACT F0050 NTS 3 er11 ennoviva 8000-12 .l Robert L. Clark. P.E. PE #39712 Structural VERTICAL SECTION A NARROW AND FULL JAMB SIDE LITE HEAD MAX. DLO -- EXTERIOR INTERIOR ALTERNATE VERSION TOP RAIL MAX. DLO EXTERIOR MAX. HEIGHT ORIGINAL VERSION BOTTOM RAIL A ALTERNATE VERSION BOTTOM RAIL INTERIOR MAX. HEIGHT P;t;,2DUCI l4 V"LS#J9 as eon *Millie P Bettnos Code Draita VERTICAL SECTION C NARROW AND FULL JAMB SIDE LITE SILL VERTICAL SECTION D OUTSWING SILL nog Dag 0146110 VERTICAL SECTIONS ALUM. FRENCH DOOR & SIDE LITES, NON - IMPACT tote: 6tleek MOW& 1/2 4 of 11 8000 -12 Robert L. Clark, P.E. PE #39712 Structural OXXO HORIZONTAL SECTION SHOWING (1) OF EACH SIDE LITE TYPE • SEE NOTE NOTE: ASSEMBLY HARDWARE QTY (3), 11" FROM TOP & BOTTOM AND ONE AT MIDSPAN DETAIL J SLAB AT GLASS BED INTERIOR DETAIL G STILES AT ASTRAGAL SEE NOTE SEE NOTE DETAIL F FULL JAMB SIDE LITE (AT HINGE JAMB) EXTERIOR PRODUCT REVISED as eatelaVires with the Marl& Mosittartee gapitratiort �. .r DETAIL H NARROW JAMB SIDE LITE (AT HINGE JAMB) Raw By: Dag F.t6 10V18/08 Rapid By: nate J.R Ott DETAIL K HINGE JAMB TO HINGE JAMB (NOT SHOWN ABOVE) DETAIL E DETAIL I JAMB, FULL JAMB JAMB, NARROW SIDE LITE JAMB SIDE LITE R += NO CHANGES 7711S8FHEE7: C checked By: fl HORIZONTAL SECTION DETAILS ALUM. FRENCH DOOR & SIDE LITES, NON! IMPACT Robert L. Clerk, P.E. PE #39712 Structural FD650 DOOR(S) ITFM1DWG#1 DESCRIPTION 1 PCIW 1=RAMEKIT PARTS 8006 FRAME - HEAD & HINGE JAMB 68006 2 8003A OUT-SWING SILL 68003A 8004C OUT - SWING SILL COVER 4 DRIP CAP 68004C 68008 A 5 7 HEAD, SILL& JAMB WEATHERSTRIP (SCHLEGAL) 8007 ► 8009 SCREW COVER U83337T8500 68007 INSTALL PLATE 68009 8 9 FRAME ASSEMBLY SCREW 118 X 1° PH QUAD 8032 ASTRAGAL END SEAL 781PQA 48032 10 8058 OUT-SW ING SILL (LOW RISE) 48058 DOOR PANEL 5 HEAD, SILL& JAMB WEATHERSTRIP (SCHLE0AL) U8333718500 20 8012 STILE 68012 21 8014 TOP RAIL, (THREADED ROD DESIGN) 68014 22 8013 23 8017 BOTTOM RAIL, (THREADED ROD DESIGN) TOP SWEEP 68013 68017 24 8016 BOTTOM SWEEP 68016 25 SWEEP SCREWS, #4X 1/2" PHIL PH 26 8015 ASTRAGAL, ACTIVE& INACTIVE 68015 27 802113 MARKINGS, JAMB SIDE 6802113 28 8020A GEAR HINGE, COVER. 68020A 29 8018 GEAR HINGE, BACKUP PLATE 68018 30 8019A GEAR HINGE, DOORSIDE 68019A 31 GEAR HINGE, BEARING 68035 32 GEAR HINGE, SEFSCREW 56-32 x1/4" 33 GEAR HINGE, MTG. SCREW I/12 x3/4" TRUSS HD. 34 GEAR HINGE, MTG. SCREW #12 x 11/2" TRUSS HD. 35 THREADED ROD 5/16-18 X 36" 6TRODA 36 FLANGED HEX NUT 5/16-18 7990NUTA 37 8039 TRUSS CLAMP 60378M 38 39 8043 S/S GEARLATCH MECHANISM (ASHLAND) 8030 LOCK BLOCK 48030 40 LATCH ASS'YSCREWS #8 X 2" SS PHIL LTR HD 78X2TPAX 41 8037 S/S SHOOT BOLT ROD (SULUVAN) 42 8045 STANDARD FLUSH BOLTS W/ SS ROD (SULLIVAN) 43 8031 SHOOT BOLT GUIDE 48031 44 SHOOT BOLT GUIDE& STRIKE SCREW 8-32 X 3/8" SS PHJLL TR HD 78X38PFTX 45 8038R RIGHT- STRIKEPLATEAT ASTRAGAL (ACTIVE HINGED LEFT) W5110-43S1 46 8038L LEFT - STRIKE PLATE AT ASTRAGAL (ACTIVE HINGED RIGHT) W5110.4481 47 STRIKBPLATE SCREWS 8-32 X 3/8" SS PHILL TR HD 78X38PFTX 48 STRIKEPLATE MIDDLE SCREW 6-24X 1/2" PH 7612FPTX 49 8036 STRIKEPLATEAT HEAD & SILL 50 51 HEAD STRIKE SCREWS SS 8 X 1/2 PHILL FH 7858ZAX STRIKE PLATE SCREWS (SILL SS 8 X 1/2 PHWLL UNDERCUT FH 78XI2PFHUX 52 8041 ACTIVE TRIM SET (ASHLAND) 53 8042 PASSIVE TRIM SET (ASHLAND) 8044 STAINLESS STEEL PASSIVE LACK GEAR(ASHIAND) 55 8014A TOP RAIL (LAG BOLT DESIGN) 68014A S6 8013A 130TTOM RAIL (LAG BOLT DESIGN) Wad Bys RevIstong ryo 10/16/00 A UPDATE STEM& ADD HEMS 68,66,67 AND 84. Bona J.IZ Rood Bp Vatic MVO Date: 0106/10 ADDEO LOW RI SILL NOCHANGES 7189 8111:E7: 68013A FD650 FULL JAMB SIDE LITE IIFil7 DWG# DESCRIPTION PGT# 1 8006 FRAME • HEAD, SILL & JAMB 68006 4 8008 DRIP CAP 68008 6 8007 SCREW COVER 68007 7 8009 INSTALL PLATE 68009 8 --- -- FRAME ASSEMBLY SCREW #8X 1° PH QUAD 78IPQA 20 8012 STILE 68012 21 8014 TOP RAIL 68014 22 8013 BOTTOM RAIL 68013 35 --- ---- -- THREADED ROD 5/16-18 X 36" 6TRODA 36 -- FLANGED HEX NUT 5/16 -18 7990NUTA 37 8039 TRUSS CLAMP 60378M 60 - ------ #8X3/4" PH SQ DRIVE TUC SCREW 78X34PSTW 61 8028 SIDE LITE HEAD TRIM 68028 62 , 8029 SIDE LITEJAMBTRIM 68029 FD6S0 NARROW JAMB SIDE LITE 1 8006 FRAME - HEAD & SILL 68006 4 8008 DRIP CAP 68008 6 8007 SCREW COVER 68007 7 8009 1NSTALLPLATE 68009 8 - --»- -• FRAME ASSEMBLY SCREW #8 X 1" PH QUAD 781PQA 68014 21 8014 TOP RAIL 22 8013 BOTTOM RAIL 68013 35 -- - - -• -- THREADED ROD 5/16 -18 X 36° 6TRODA 36 -- - - - - -- FLANGED HEX NUT 5 /16.18 7990NUTA 37 8039 TRUSS CLAMP 60378M 60 ---- - - ---- #8 X 3/4" PH SQ DRIVETEK SCREW 78X34PSTW 61 8028 SIDE LITE HEAD TRIM 68028 70 8010 FRAME, JAMB 68010 ASSEMBLY KIT 80 8033E FRENCH DOORASSEMBLYBEAM 6803313 81 --- - - - - -- #10-24 X 21/2° PH SCREW 82 ------- #10.24 HEX NUT 83 -- -- #12 X 1 1/2" TRHD TEK SCREW 68025 84 8056 SUBSILL(OPTIONAL) 68056 GLASS. BEADS & SILICONE 90 -- GLAZING SEALANT, DOW CORNING 899, 983, 995 OREQUIVA LENT 100 - ---- -- 3/16" TEMPERED GLASS 101 --- • ----•- 7/8" LG. GLASS (3/16"T, 1/2" AIR SPACE, 3/16"T) 102 8025 3/16" BEAD 68025 105 8022 BACK BEAD 68022 106 8026A SLBACKBEAD 68026A 108 8024A 7/8" IGBEAD 68024A 109 1224 VINYL BULB WSTP (THICK) 617247 PRODUCT REVISED res coo1plsrlug F1 Eda llildlisg Coda AteeVattee 140 Exploitive 15 DONA41 Dew • By: Date: F.K. 12/30/04 1070 TECHNOLOGYORNE NOKOM124 FL 34276 P.O. BOX 1628 NOKOMIS FL 34274 PARTS LIST ALUM. FRENCH DOOR & SIDE LITES, NON-IMPACT 1/2 Robert L. Clark, P.E. PE #39712 Structural L 1.000 ft-3.636 - ----- #8006 6063 -T6 FRAME, HEAD, JAMB AND SIDELITE SILL #8009 6063 -T5 INSTALL PLATE Tom_ 1.938 T .062 1.278 2.236 .583 Tf.-- 3.636 ---0-1 #8003A 6063 -T6 OUT -SWING SILL .583 .062 1.376 r-4--IIA7 1 I- *--- -- 3.636 ---04 ,Qp #8056 6063 -T6 OUT -SWING LOW SILL .100 8.250 #8013 6063 -T6 BOTTOM RAIL 1.938 1 -•— .100 8.250 #8013A 6063 -T6 BOTTOM RAIL, LAG BOLT DESIGN 1.353 I-iS— 1.033 #8004C 6063 -T5 OS SILL COVER T 2.000 L .074 1.498 1+-- ---- -- 3.990 #8012 6063 -T6 STILE h 4.434 #8014 6063 -T5 TOP RAIL 1.467 4.434 ■-{ #8014A 6063 -T5 TOP RAIL, LAG BOLT DESIGN #8008 6063 -T5 DRIP CAP 1.940 .050 #8017 6063 -T5 TOP SWEEP 2.240 #8016 6063 -T5 BOTTOM SWEEP #8015 6063 -T6 ASTRAGAL 1.160 l armil .311 .040 — #8007 6063 -T6 SCREW COVER PRODUCT MIMED eeeep4ikag rierkie Y,.,,.> ,:,,,,..,: O ! . (/f le Revsede bag F:IG 10/10198 MOON: A UPGIW YTF14t8, AMP LOW RISE SILL ANDSEGONO EXTRUSION SHEET. Renee: Reveille RIC Daft 12/30/04 Rem B Redstone 0 antotsetEe NO CHANGES 11119 SHEET. 1070 TECHNOLOGY DRIVE NOKOMIS FI.34276 P.O. BOX 1529 NOKOMIS, FL 34274 EXTRUSION PROFILES ALUM. FRENCH DOOR & SIDE LITES, NON- IMPACT Entleeleke: asks F12650 /2 7 a 11 8000-12 C er/.. Robert L. Clark, P.E. PE #39712 StrUctiral 2.260 E .075 #8021B 6063 -T6 GEAR HINGE, JAMB .050 .438 2.622 ----e-1 #8028 6063 -T5 SL HEAD TRIM .045 .442 -� .965 #8022 6063 -T5 BACKBEAD .072 .742 1-0:--t .353 #8020A 6063 -T6 GEAR HINGE, COVER 3375 --- ----01 j .125 T .050 -' .325 #8056 6063 -T4 SUBSILL, OPTIONAL 1 .965 7 1.169 res-- 1- #8026A 6063 -T5 SL BACKBEAD .045 .750 [.142 .301 1-+-.. 1.763 4.-17 #8018 6063 -T5 HINGE, BACK -UP r 075 V/ • 14 2.438 -40-I T #8019A 6063 -T6 GEAR HINGE, DOOR .0621 1.000 3.636 ---* -1 1- .045 818 r--- #8023A 6063 -T5 7/16" BEAD #8010 6063 -T6 NARROW SL JAMB #8024A 6063 -T5 I.G. BEAD .125 3.251 r 1.635 ier #8033B 6105 -T5 FD ASS'Y BEAM 2.313 -fel ui .050 re- 1.812 -IA 1.000 .100 #8039 6063 -T6 TRUSS CLAMP #8029 6063 -T5 SL JAMB TRIM tsar. F.I4 esar 10/16100 RevIsIoner A UPGRADEIIEM3 Remf Bar: .4hL Dike 00/22/09 8 NEW PAGE Revs Bp Jdt Deter • 01/25110 0 NO CHANGES THIS WEE. Daiwa* Date: Cheoke08p. De o F.K 12/30/04 1070 TECHNOLOGY DRIVE NOKOMIS. FL 34275 P.O.SQX1620 NOKOMIS, FL 34274 EXTRUSION PROFILES (CONT.) txae ALUM. FRENCH DOOR & SIDE LITES, NON- IMPACT SerhoNotiob s raawekNo. F0850 1/2 8 a 11 8000 -12 C MIX= REVISED estegttleg ,tta4ke Ffartds Corte „ Atarresses 0- j?$ +,► gate , rf;r!;, a r ilA Robert L. Clark, P.E. PE #39712 Structural 161- 161=. 11" OMNI JAMB ANCHORS HT. QTY. 95 3/4" - (5) 91 3/4" - (5) 87 3/4" - (5) 83 3/4" - (5) 79 3/4" - (5) 1 11" ---T DETAIL A (CONCRETE) A (SINGLE PANEL) ANCHOR TYPES: 10R2 JAMB ANCHORS HT. QTY. 953/4 " -(8) 91 3/4" - (8) 87 3/4" - (8) 83 3/4" - (7) 79 3/4" - (7) 1 11" 10.571" — MAX. o.C. 1 11" ---T A DETAIL B (WOOD) (SINGLE PANEL) ANCHOR TYPES: 20R3 3:: -Tr- I 161-- ( I ID - 3" 3" MIN. HEAD & SILL 11 " _ 30 MIN.,i,l_ TYP. ANCHOR -T TVP. CLUSTER _ (TYPICAL) JAMB ANCHORS HT. QTY. 953/4 " - (5) 91 314" - (5) 873/4 " - (5) 833/4 " -(5) 79 3/4" - (5) 1 11 11 1 A DETAIL C (CONCRETE) SEE NOTE 5 (2 OR MORE PANELS) REGARDING APPLICABLITY ANCHOR TYPES: OF ENCIRCLED 1 OR 2 ANCHOR LOCATIONS 11" (2) EQ. SP. TYP. 11 1 Q 1111 12 ", 9" 6" -- 3" 1 11)) 1 1 I 1 1 C. HEAD & SILL ANCHOR CLUSTER (TYPICAL) A (3) EQ. SP. TYP. I l i l 1 0 Ilil II11 O-1 JAMB ANCHORS HT. QTY. 95 3/4" - (8) 91 3/4" - (8) 873/4 " -(8) 833/4 " - (7) 793/4 " -(7) 1111 Q 1 17_1 11" _ 10.571" MAX. _ O.C. ---T 11" A DETAIL D (WOOD) (2 OR MORE PANELS) ANCHOR TYPES: 20R3 ANCHORAGE SPACING REQUIREMENTS: 1. DETAILS A AND B ABOVE REPRESENT ANCHORING OF SINGLE X DOORS, OR INDIVIDUAL SIDE UTE 0 PANELS WITH FULL OR NARROW WIDTH JAMBS. DETAILS C AND D ABOVE REPRESENT ANCHORING OF ANY MIXTURE OF DOUBLE XX DOORS, SINGLE X DOORS, NARROW JAMB OR FULL JAMB SIDE LITE PANELS, FOR MULTIPLE -PANEL INSTALLATIONS OF TWO OR MORE PANELS. UNLESS OTHERWISE STATED, DIMENSIONS OF DETAILS A THROUGH D ARE MAXIMUMS. 2. ANCHOR TYPES: 1 -1/4" ELCO ULTRACON 2 -1/4" ELCO SS4 CRETE -FLEX 3 - #12 STEEL SCREW (G5) A CONCRETE SUBSTRATE USE TYPE 1 AT 1 3/8" MIN. EMBEDMENT OR TYPE 2 AT 1 3/4" EMBEDMENT. 1 3/4" MIN. EDGE DISTANCE FOR BOTH. WOOD SUSTRATE - USE TYPE 2 OR TYPE 3 AT 1 3/8" MIN. EMBEDMENT. 3. SINGLE PANEL CONFIGURATIONS : (DETAIL A, CONCRETE SUBSTRATE. DETAIL B, WOOD SUBSTRATE) A HEAD AND SILL 6" MAX. FROM FRAME CORNERS. JAMBS 11" MAX. FROM FRAME CORNERS, 18.500" MAX. O.C. CONCRETE SUBSTRATE (DETAIL A) AND 10.571" MAX. O.C. WOOD SUBSTRATE (DETAIL B). 4. TWO OR MORE PANEL CONFIGURATIONS : (DETAIL C, CONCRETE SUBSTRATE) HEAD AND SILL 8" MAX. FROM FRAME CORNERS, AND AT 3" AND 6" MAX. ON EACH SIDE OF ASSEMBLY BEAM AND /OR ASTRAGAL LOCATIONS (CLUSTER OF 4). JAMBS....11" MAX. FROM FRAME CORNERS AND 18.500" MAX. O.C. 5. TWO OR MORE PANEL CONFIGURATIONS : (DETAIL D, WOOD SUBSTRATE) HEAD AND SILL 6" MAX. FROM FRAME CORNERS, AND AT 3 ", 6 ", 9" AND 12" MAX. ON EACH SIDE OF ASSEMBLY BEAM AND /OR ASTRAGAL LOCATIONS (CLUSTER OF 8). PLUS ENCIRCLED ANCHORS OUTSIDE CLUSTERS, REQUIRED ONLY ON PANEL WIDTHS OVER 27 3/4 ". JAMBS 11" MAX. FROM FRAME CORNERS AND 10.571" MAX. O.C. Rend ftv FJC t>aa� 101t6/08 Rend fly: Wdb: J.R. 09=00 Road Op PMes J,R 0l/10 F..K 12/30104 PRODUCT REVISED as complying with :the Plod* Raiding Cody �N 15 REVISED A?IW HORAOE PER RBG2004ANDRIVNBENOTES Rotiom: Cheated Aily. C NO CHANGES 7HISSHEET: ONANGED "PAPOON'T070.7RACON 1070 TECHNOLOGY DRIVE NOKOMIS, FL 34275 P.O. BOX 1528 NOKOMIS, FL 34274 ANCHORAGE SPACING TaNs ALUM. FRENCH DOOR & SIDE LITES, NON IMPACT twissatode F0650 NTS Moo 9 of 11 8000 -12 C 0t,0) ' Robert L. Clark. P.E. PE #39712 Structural CONCRETE ANCHOR (NOTE 1) 1/4" MAX. GROUT, SEE NOTE 6 1/4" MAX. GROUT, SEE NOTE 5 CONCRETE ANCHOR SEE NOTE 1 OPTIONAL f TYPICAL SIDE LITE SILL (DIRECT TO CONCRETE) 6:3.4 3.4 KSI MIN.; ; CO NCRETE •r, ., .r.r ,s, �. •A.t • •,-:r:.,. EMBED. :•• SEE NOTE 1 OPTIONAL SIDE LITE SILL (SUBSILL TO CONCRETE) 1/4" MAX. GROUT SEE NOTE 5 WOOD ANCHOR, SEE NOTE 2 TYPICAL SIDE LITE SILL (DIRECT TO WOOD) EXTERIOR INTERIOR E> (ALL HEAD & SILL SECTIONS) CONCRETE ANCHOR, SEE NOTE 1 nq CONCRETE ANCHOR SEE NOTE 1 TYPICAL DOOR & SIDE LITE HEAD Q 1x WOOD SEE NOTE 3 2x WOOD SEE NOTE 3 1/4" MAX. WOOD ANCHOR, GROUT SEE NOTE 2 SEE NOTE 5 OPTIONAL OPTIONAL SIDE LITE SILL (SUBSILL TO WOOD) ®WOOD ANCHOR SEE NOTE 2 NOTES: 1. FOR CONCRETE APPLICATIONS IN MIAMI -DADE COUNTY, USE ONLY MIAMI -DADE COUNTY APPROVED ELCO 1/4" ULTRACONS OR 1/4" SS4 CRETE -FLEX. MIN. DISTANCE FROM ANCHOR TO CONCRETE EDGE IS 1 3/4 ". MIN. EMBEDMENT: 1/4" ULTRACON -1 3/8", 1/4" SS4 CRETE -FLEX -1 3/4 ". 2. FOR WOOD APPLICATIONS USE #12 STEEL SCREWS (G5) OR ELCO 1/4" SS4 CRETE -FLEX -1 3/8" MIN. EMBEDMENT FOR EITHER. 3. WOOD BUCKS DEPICTED AS 1x ARE LESS THAN 1 1/2" THICK. 1x WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS DEPICTED AS 2x ARE 1 1/2" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 4. FOR ATTACHMENT TO ALUM: THE MAT'L SHALL BE A MIN. STRENGTH OF 8063-T5 AND A MIN. OF 1/8" THICK. THE ALUM. STRUCTURAL MEMBER SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE DOOR FRAME SIMILAR TO THAT SHOWN IN THE DETAILS ON THIS SHEET FOR 2x WOOD BUCKS. THE ANCHOR SHALL BE A #12 SMS WITH FULL ENGAGEMENT INTO THE ALUM. IF THESE CRITERIA ARE MET, THE PRESSURES SHOWN ON SHEET SAND ANCHORAGE SPACING FOR WOOD SHOWN ON SHEET 9 MAY BE USED. 5. IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, NON - SHRINK, NON - METALLIC GROUT, 3400 PSI MIN., (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. PRODUCT IdEV13E• as complying with the Mlles Code Are aNt Olt + • j •" ExpireStet Date 'lire !I(! j ( 5 .fi� ^•� -'te `! . F.K rams A U P DA 1 E ANCHOR OP T I O N S AND N O T E 8' Roved Sy: J.R. Roved By: AFL Down 41 F.It: Dew 0108 Cita 01/1161!0 12!30104 Rralonv 9 ADDED SWUM SILL DETAIL. REORGANIZED DETAILS ReAreee c C X I N G EO TA PC O A P TO i l L T R A C O N Unclad Sy: cog 1010 7ECHNOLOOYDRIVE NOKOMIS, FL 34275 P.O BQX 1520 NOKOMIS, FL 34274 ANCHORAGE DETAILS INN ALUM. FRENCH DOOR & SIDE LITES, NON-IMPACT sedesmodok F0650 auk 1/2 ' Shut theft" 10 of 11 I 8000 -12 Rev C Robert L. Clark, P.E. PE #39712 Structural • • • <2] EXTERIOR INTERIOR (ALL SILL SECTIONS) • ' 114" MAX. GROUT, SEE NOTE 5, SHEET 10 1 CONCRETE A ANCHOR SEE NOTE 1, SHEET 10 / EMBED. SEE NOTE 1, SHEET 10 t TYPICAL DOOR SILL (DIRECT TO CONCRETE) INTERIOR (ALL JAMB SECTIONS) EXTERIOR /Wades FJC RevadDy: Alt Raved* lkist 10/1W00 OnAga 0942A79 nog 01/211/10 Ilevistans: A AEMBED. SEE NOTE 1, SHEET 10 CONCRETE ANCHOR, SEE NOTE 1, SHEET 10 1/4" MAX. GROUT, SEE NOTE 5, SHEET 10 OPTIONAL A .6.?!. • • - .; EMBED. KSI SEE NOTE 1, SHEET 10 •, 1 OPTIONAL DOOR SILL (SUBSILL TO CONCRETE) , • 3.4 KSI MIN. CONCRETE -0••••......!:•:. • A 1/4" MAX. SHIM —0-1 1-.4— CONCRETE ANCHOR, SEE NOTE 1, SHEET 10 AEMBED. A SEE NOTE SHEET 10 1-•; 1 • • A 3.4 KSI CONCRETE OR 1.5 KSI MIN. CMU • • 1 X WOOD, SEE NOTE 3, SHEET 10 ' • • 1/4" MAX. SHIM WOOD A ANCHOR SEE NOTE 2, SHEET 10 1/4" MAX. GROUT, A SEE-1 NOTES, SHEET 10 TYPICAL DOOR SILL (DIRECT TO WOOD) CONCRETE ANCHOR, SEE NOTE 1, SHEET 10 411/11/111i11111111111111 1 111;111 1.11111.11111. TYPICAL DOOR & SIDE LITE JAMB 2x WOOD, SEE NOTE 3, SHEET 10 WOOD ANCHOR, SEE NOTE 1, SHEET 10 1/4" MAX. GROUT, SEE NOTE 5, SHEET 10 OPTIONAL OPTIONAL DOOR SILL (SUBSILL TO WOOD) ACONCRETE A ANCHOR, 1 3/8" SEE NOTE 2, MIN. I-0— SHEET 10 1/4" MAX. SHIM —0-1 I-0-- NEW SHT. AOD SWUM AND AL7ERNME TOP a BOTTOM RAIL MORMONS. Revlon& a -Raidolonx 0 ADDED LOW ME SILL OP710AL REORGANIZED DETAILS. NO CHANGES 1M$ 9T. Dawn EIN Daft Checked Er Das: RIG 1011E1/06 - • 1070 TE016101.00Y DRAM NOKOMIS, FL 34275 P.a 119X 1629 NOKOMIS, FL 34274 Desapite ANCHORAGE DETAILS (CONT.) ALUM. FRENCH DOOR & SIDE LITES, NON-1MPACT oedema** FD750 1/4 ehmit :11 of 11 wow*. 8000-12 PRODUCT DMVISED sosetOws wftbi Ready Dora* Cos* Mospleasis Oradea gobert L 'PE #3,9712 t • • • StrtIctliki TABLE 1 Truss Anchors NVTA and Riveted Truss Anchors with Seat NVTAS H Length (in) Product Code Gauge seat Gauge strap 16 NVTA -16 NVTAS 212 20 14 18 NVTA -18 NVTAS 214 20 14 20 NVTA -20 NVTAS 216 20 14 22 NVTA -22 NVTAS 218 20 14 24 NVTA -24 NVTAS 220 20 14 26 NVTA -26 NVTAS 222 20 14 28 NVTA -28 NVTAS 224 20 14 30 NVTA -30 NVTAS 226 20 14 36 NVTA -36 NVTAS 232 20 14 48 NVTA -48 NVTAS 244 20 14 No. of Fasteners each strap 10d Maximum Allowable Load (Ibs) L2 Single & Double Straps Uplift Single Strap Uplift Double> NVTA L1 Single & Double Straps 5 757 1514 250 500 6 805 1610 250 500 7 854 1708 250 500 8 902 *1804 250 500 9 951 *1902 250 500 10 999 *1998 250 500 11 1048 *2096 250 500 12 1096 *2192 250 500 13 1145 *2290 250 500 14 1193 *2290 250 500 *Note: For 8 or more nails per strap, use double truss for double straps. General Notes: 1. Steel shall conform to ASTM A653, structural grade 33 (Min. field 33 ksl) and a minimum galvanized coating of 0 60 per ASTM A525. 2. Allowable loads are based on National Dosing specifications (NDS) for wood construction, 2001 Edition and Florida Building Code 2004. 3. Design loads are for Southern Pine species with a specific gravity of 0.55. Allowable loads for other species shalt be adjusted accordingly. 4. Nail values are based on NDS table 11P, G•0.55 for common wire nails and have been reduced for Penetration Depth factor CD. 5. Allowable loads for wind uplift have already been increased by a duration factor of 1.8 for anchor nails. 33%6 steel stress increase Is not used in the tabulated values. 6. Allowable loads for more than one direction for a single connection cannot be added together. A design load which can be divided into components in the directions given must be evaluated as follows: Allowable liplltt + eLl1 + o�a Te 2 1.0 7. Allowable loads ore bused on 1r thick wood members unless otherwise noted. 8. All tie beams and grouted concrete masonry shall comply with chapters 19 and 21 of 2004 FBC. Concrete for tie beams and grout and mortar for concrete masonry shall be a min. of 2500 pet. Concrete masonry shall comply with ASTM C90. 9. All tests have been conducted in accordance with ASTM D -1761. 1" TABLE 2 Truss Anchors NVTA and Riveted T H Length (in) Product Code Gauge seat Gauge strap 16 NVTA -16 NVTAS 212 20 14 18 NVTA -18 NVTAS 214 20 14 20 NVTA -20 NVTAS 216 20 14 22 NVTA -22 NVTAS 218 20 14 24 NVTA -24 NVTAS 220 20 14 26 NVTA -26 NVTAS 222 20 14 28 NVTA -28 NVTAS 224 20 14 30 NVTA -30 NVTAS 226 20 14 36 NVTA -36 NVTAS 232 20 14 48 NVTA -48 NVTAS 244 20 14 Perpendicular to wall L2 No. of Fasteners each strap 10d x 1.5" Maximum Allowable Load (lbs) L2 Single & Double Straps Uplift Single Strap Uplift Double s'` L1 Single & Double Straps NVT 5 1032 2236 250 500 6 1127 2254 385 565 7 1136 2272 520 630 8 1144 *2288 520 630 9 1153 *2306 520 630 10 1161 *2322 520 630 11 1170 *2340 520 630 12 1178 *2356 520 630 13 1187 *2374 520 630 *Note: For 8 or more nails per strop, use double truss for double straps. P• 8D Reinforcements Required Parallel to wall VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 2 ?" "4-- Concrete Tie Beam or Tie Beam formed with concrete filled masor ss �ir�e Markle Aa phoce No I 5i0 O 0 0 1? 2j" O ' Holes Dia. NVTA, NVTAS u e Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 PHONE: (305) 694 -0397 FAX: (305) 694 -0398 NVTA AND NVTAS TRUSS ANCHORS DWG #: NU --2 Sheet: 1 of 4 Dote: FEB. 13, 2003 Revisions: July 7, 2003 June 15, 2005 Jan. 10, 2006 July 19, 2006 • e • • • • • • • • • • • • • • • • • • • •\ TABLE 5 NVRT Flat and Twisted Rafter Ties Length (in) Product Code Gauge 12 NVRT -12 14 16 NVRT -16 14 18 NVRT -18 14 20 NVRT -20 14 22 NVRT -22 14 24 NVRT -24 14 30 NVRT -30 14 36 NVRT -36 14 48 NVRT -48 14 16d Fasteners Maximum Up ift Load (Ibs) TOTAL AMP* Flat Ties Twisted Ties 8 4 725 724 10 5 861 860 12 6 998 996 14 7 1135 1132 Notes: 1. Specify "F" for Flat and "T" for Twisted when ordering. 2. Fastener values are based on a minimum 1r thick wood members. 3. * Indicates no. of nails In each connected wood member. 4. See General Notes, sheet 1. 0111 Iv HALF HALF Connected Connected to truss Alm to wall �1r •• •• •• •• 00 °° °• % % / L LENGTH UPLIFT TABLE 6 NVRT Twisted Rafter Ties to Concrete Tie Beams or Concrete Filled Masonry Length (in) Product Code Gauge 12 NVRT -12 14 16 NVRT -16 14 18 NVRT -18 14 20 NVRT -20 14 22 NVRT -22 14 24 NVRT -24 14 30 NVRT -30 14 36 NVRT -36 14 48 NVRT -48 14 Notes: No. of 16d nails to Wood Framing No. of 1" diameter Tapcons to Concrete Maximum Uplift Load (Ibs) 4 6 722 5 7 856 6 8 991 7 9 1125 PRODucr aistowsD es�wkbdiedlonift Diktess 1. ITW tapcons shall be embedded a minimum of 14" into concrete tiebeam or tiebeam formed with concrete filled masonry. ITW tapcons shall have a min. edge distance of 2i" and minimum spacing of 14" as shown. 2. See General Notes, sheet 1. 3. All tapcons must be in the some row space at 1X" on centers. Do not use holes in the opposite row. Strap must be long enough to accommodate required tapcons. apcon 2 :" Min. edge distance Reinforcement required Tie Beam formed with concrete filled mosonary or concrete tie beam VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 1 i" 0 0 1" — o O — NVRT Anchor Holes dia. T" Do not Use circled holes Nu "- Vu e Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 PHONE: (305) 694 -0397 FAX: (305) 694 -0398 NVRT FLAT AND TWISTED RAFTER TIES DWG #: NU -2 Sheet: 3 of 4 Date: FEB. 13, 2003 Revisions:July 7, 2003 June 15, 2005 Jan. 10, 2006 July 19, 2006 1 slot 0.20r V N. 4' EMB. NVTH 1) §' Truss plate req. equired to transfer Toad to bottom chord Truss plate required to transfer Toad to bottom chord Reinforcements Required .:a . . Double Seal) Double Truss Concrete Tie Beam or Tie Beam formed with concrete filled masonry Reinforcements ,*y Required %OW Single Strap Single Truss Concrete "Re Beam or Tie Beam formed with concrete filled masonry 5 Nails in Front (Min.) Nails 10d x 1.5' 1,08t1C1' RENEWED eaadin6tr I� 3 AceReenceNo # i -4 1' .01kr, Nails on Front & Back Shall be off centered TABLE 7 Truss Anchors NVTH It o•I H Length (In) Product Code Gauge seat Gauge strap 12 N VfH -16 14 NVTH -18 18 14 18 14 16 NVTH-20 18 14 18 NVTH -22 18 14 20 NVTH -24 18 14 22 NVTH -26 18 14 24 NVTH -28 18 14 26 NVTH -30 1.8 14 32 NVTH -36 18 14 44 NVTH-48 18 14 VIPIN N. TOLAT, PE (CIVIL) PL. REG. # 12847 18123 L CREEK LANE HOUSTON, TX 77068 No. of Fasteners in each Strap 10d x 1.5" Maximum Uplift Loads (Ibs) Single Strap on Single Truss Double Straps on Double Truss 1032 2064 6 1222 2444 7 1275 2550 8 1329 2658 9 1383 2766 10 • 1437 2874 11 1490 2980 12 1544 3088 13 1598 3196 NVTH Vu e Industries, Inc. 1053 -1089 East 29 Street Hialeah, Florida 33013 Phone: 308) 694 -0397 Fay 305) 694 -0398 NVTH ANCHORS DWG #: NU-2 Sheet: 4 of 4 Date: JULY 19, 2006 . Revisions: TABLE 3 NVBH 24 BUTTERFLY HANGER Notes: 1. Use all specified fasteners in schedule to achieve values indicated. 2. Values are based on 1e header and Joist thickness. 3. See General Notes, Sheet 1. SYMM.@ Mid Span DOWNWARD LOAD TABLE 4 NVUH 26 JOIST HANGER kl Di PRODUCT CODE GAUGE I FASTENER ALLOWABLE g 3 a SCHEDULE LOADS (lbs.) US g i 15 F- 10 2233 1213 2 42 DOWNWARD GRAVITY LOADS 2x4 NVBH24 18 12 6 1113 Notes: 1. Use all specified fasteners in schedule to achieve values indicated. 2. Values are based on 1e header and Joist thickness. 3. See General Notes, Sheet 1. SYMM.@ Mid Span DOWNWARD LOAD TABLE 4 NVUH 26 JOIST HANGER kl Di PRODUCT CODE GAUGE I FASTENER SCHEDULE ALLOWABLE LOADS (lbs.) g 3 s" $x 7 DOWNWARD GRAVITY LOADS WIND UPUFT LOAD 2x6 NVUH26 14 20 10 2233 1213 Notes: 1. Use all specified fasteners in schedule to achieve values indicated. 2. Values are based on 3" header thickness and 13" Joist thickness. 3. See General Notes, Sheet 1. VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTERN CREEK LANE HOUSTON, TX 77068 15")) SYMM.@ Mid Span UPLIFT mon= MEMO AC010000 NO 02 • 11 DOWNWARD LOAD Vu e Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 PHONE: (305) 694 -0397 FAX: (305) 694 -0398 NVBH 24 AND NVUH 26 HANGERS Al.t)6 DWG #: NU -2 Sheet: 2 of 4 Date: FEB. 13, 2003 Revisions: July 7, 2003 June 15, 2005 Jan. 10, 2008 July 19, 2008 TABLE 1 / JOIST SUPPORTS ' • 18 C NVJH JOIST SUPPORTS • C Allowable Loads (Ibs) Product Code 1 Dimension Inches) li • BS ' Joist Size, Double Header Size , - San le 9 Header Size Fasteners ' 'Gravity toads Y Up1� lids •.., Double,- ' Header Single . Header Joists • . Double Header' fie; . Header Ie & Double - Headers - W • , NVJH24 1 % 3% . 3 22x6 • 2 -t8 ' - •• 6 • 6 -10d 6 -10d x 13` -f- 4-10d 3c 11f :744 744.. -^ - NVJH26 1 % 5' 3 • r 22x8 ' 2-2x6 . 2 -2x8 , 2x8 ' 10 -10d 10-1ad z 1,1r •-10d x 11�` .t 240 . ( 2.4 O 821 ' NVJH28 a .i % ' ' s% r 3 2x8 , 2x10 2x12 : 2 -2x8 2 -2x10 2 -2x12 1 - 2x8 2x10 J 2x12 14 --10d - 14-10d x 1$-•7 -10d x 11S' ' ; (73G ' (736. 1079' Single Header , 1--2X 3" Double Header 2 -2X NVJH 26 es shown ' NVJI-1 24 do 28 , similar but with - different holes. General Notes: 1. Steel shall conform to ASTM-A653, structural grade 33 (Min. yield 33 ksi) and- a minimum galvanized coating of G 60 per ASTM A525. • 2. Allowable loads are based on National Desing specifications (NDS) for ' Qeot a »dt F le C3 u; Icy►', C�.� -a. 2ocG 26o Wood construction, � /o Edition. •"'3 3. Design loads are for Southern Pine species with a specific gravity of 0.55. - Allowable loads for other species shall be adjusted accordingly. 4. Nail values are based on NDS table lig, G=0.55 and have been reduced • for Penetration Depth factor.. 5. Allowable laads.for wind uplift and lateral loads have already been ' increased by a duration factor of 60% for anchor nail. No. • increase is allowed for -steel stress: , - 6. Allowable loads for more than a single connetion cannot be added together. A design load which be divided into components in the direction - given crust be evaluated as follows: • Actual Uplift . Actual Li + Actual L2 < -1.0 Allowable Uplif Allowable L1 Allowable L2 7. Allowable loads are base on 1 Y211 thick wood members unless otherwise • noted. S. All tests have been conducted in accordancip sayaga?--1761. e•rlrOrl > .oDUcTR sE» VIPIN N. TOLAT, PE (CIVIL) f•'„�' a a 8 the Florida �7�71 1 >�eale FL. REG. # 12847 lse No iS -0 r 15123 LANTER CREEK LANE Ezpbadsa 1':r•■l7.#37., HOUSTON, TX 77068 N Mem " V ue Industries, Inc... . rte . 'cat f 1053 -1059 East 29 Street Hiialeab. Florida 33013 (305) 694 -0397 FAX: (305) 694-0398 NVJH JOIST SUPPORTS • DWG #': Sheet: NU-3 1of3' Date: Revisions= (1)11/10103 -. (3) 44!27145 ;. TABLE 2 ' TOP PLATE ANCHORS ' NVTP & NVTPH ' Size 1 Product Code - Gauge 9 e Dimensions (in) A • 12 • B 2x4/4x4, NVTP4 , 20 • 3" ' 93$' 8" 2x6/4x6, NVTP6 . 20 • 5r • 4- %Mk 3 »..: Lea Scream 8" 2x8/4x8, NVTP8 - 20 • 7" ' • 8" 2x4/4x4• NVTP4H • 18 . 31" • 8» 2x6/4x6 • NVTP6H . 18 . 5" ' 8" , 2x8 /4x8' NVTP8H • 18 • 7" / g" ' Product code ' Total number of fasteners • 10d x 1 r Wind Fa Me -G's ' Max. Uplift Capacity (Ibs) 6 • 8 ' 10 - 12 • NVTP 4,6,8 ' 82.8. 1087 , 1346 ' 1605 - NVTP 4H,6H.8H 93$' 12.07, 14 7G, (74.5 Notes: • 1. See General Notes, Sheet 1. ' 2. One half of all specified fasteners shall be used on each side of the stud to achieve tabulated values. 1 Stud x 4 Minimum TABLE 3 NVSO 236, 16 GAUGE, HEAVY DUTY • FACE MOUNT JOIST HANGER Joist Size Header Size , • Fasteners , Allowable Loads (Lbs.) • Header . Joist • GRAVITY Uplift 2x6 -8 14 -10d • 6 -lad • 1758 , 1108 , 2 -2x8 - 2 -2x10 - 2 -2x12 14-16d • 6 -16d • 1875 ., 1279 , 4- %Mk 3 »..: Lea Scream 6 -16d . 8: 00 ' 1217 ' Notes: 1. See General Notes, Sheet 1. 1)" Header 2 -2X Minimum BOLT HOLES 1/2" DIA. - NAIL HOLE 3/16" DIA. i Joist 1 -2X Minimum 1111,163140 9°:bi:!' r18VESED wises awe" van., Florida VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 15123 LANTER CREEK LANE HOUSTON, TX 77068 uet Control N V ue Industries, Inc. 1053 -1059 East 29 Street Maleah, Florida 33013 (305) 694 -0397 FAX: (305) 694 -0398 NVTP & NVTPH PLATE ANCHORS, NVSO 236 JOIST HANGER DWG #: NU-3 Sheet: 2 of 3 Date: JULY 10, 2003 Revisions: (1)11/10/03 (2)]2/11/03 (33 04/27/05 • 1 TABLE 4 18 Gauge NVHC 43 8c NVHC 43/2 HURRICANE CLIP. PRODUCT CODE DESCRIPTION ' FASTENERS • DESIGN LOADS (LBS) HEADER JOIST • • UPLIFT 1.1 ' L2 • NVHC 43 • Hurricane Clip — Wide ' 9 -10d • 9-10d, '687* 407 • 308 A NVHC 43/2 ' Hurricane Clip — Widex2 ' .10 -1Od' 10 -10d' 1917 547, 432 Notes: 1. See General Notes, Sheet 1. i 1711 f1 2 374 NVHC 43/2 For Uplift, use two clips, one on each side to comply with section 2321.7 of ' the FBC 2004. i 5Y" ' NVHC 43 ' UPLIFT 1 —2X(1 NsWi de) • VIPIN N. TOLAT, PE (CIVIL) FL. REG. # 12847 151231 ANTER CREEK LANE HOUSTON, TX 77068 MONO* IhMadill ife • = 4;' gVI wcTREVISED ` tirs sg vela the Thrift SL,. ,a/ Nu °Vue Industries, Inc. 1053 -1059 East 29 Street Hialeah, Florida 33013 (305) 694 -0397 FAX: (305) 694 -0398 NVHC 43 & NVHC 43/2 HURRICANE CLIP. DWG #: NU -3 Sheet: 3 of 3 Date: JULY 10, 2003 Revisions: (1) 11/10/03 (2) 12/11/03 (3) 4/27/05 TABLE OF CONTENTS SHEET # DESCRIPTION 1 ELEVATIONS & GENERAL NOTES 2 ELEVATIONS 3 ANCHORING LAYOUTS 4 ANCHORING LAYOUTS 5 VERTICAL SECTIONS & GLAZING DETAILS 6 HORIZONTAL SECTIONS & DETAILS 7 COMPONENTS 8 BILL OF MATERIALS UNIT SIZE DESIGN PRESSURE RATING DOUBLE DOOR UP TO 75 1/8" X 98" +60 PSF / -62 PSF SINGLE DOOR UP TO 38" X 98" 98" MAX. O.A. UNIT HEIGHT 84 23/32" MAX. Q.L.O. MULTI -LOCK W/ SHOOT BOLTS GENERAL NOTES 1. THIS PRODUCT IS DESIGNED TO MEET THE 2004 FLORIDA BUILDING CODE INCLUDING HVHZ. INSTALLATION OF THIS PRODUCT OUTSIDE THE "HVHZ" SHALL MEET THE APPLICABLE CODE REQUIREMENTS FOR WINDBORNE DEBRIS REQUIREMENTS. 2. THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT. IMPACT PROTECTION IS NOT REQUIRED FOR THIS PRODUCT. 3. PRODUCT ANCHORS SHALL BE AS LISTED AND SPACED AS PER DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT A PART OF THIS APPROVAL. 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE AND IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 5. THESE DOOR SYSTEMS HAVE BEEN TESTED AND APPROVED FOR DESIGN PRESSURES NOT TO EXCEED THOSE IN THE DESIGN LOAD INFORMATION CHART SHOWN ON THIS SHEET. 6. FOR REFERENCE SEE TEST REPORTS: ATI 61976.01 - 301 - 18.03- 31369.01 & 03- 31369.02. 7. THE DESIGNATIONS "X° AND "XX" STAND FOR THE FOLLOWING: X = SINGLE OUTSWING DOOR XX = DOUBLE OUTSWING DOOR • NOTE: ELEVATIONS SHOWN ON THIS PAGE WITH 2X BUCKING AND WITHOUT LOCATING FLANGES. FOR OPTIONAL LOCATING FLANGES, W/ DIRECT MOUNT SCREWS, SEE SHEETS 3 & 4. MAX UI HEI 751/8" MAX O.A. UNIT WIDTH 26 5/8" MAX. D.L.O. 5-PT. LOCK 37 1/16" 35 7/8" PANEL & ASTRAGAL PANEL WIDTH 26 518" MAX. D.L.O. 5-PT. LOCK 38" MAX. OA. UNIT WIDTH Toi g / VII A 8" . O.A. JIT GHT 84 23/32" MAX. D.L.O. I� / INACTIVE \ \ ti i � \ ACTIVE 1 I /36" / j/ Q Aft a 37 1/16" 35 7/8" PANEL & ASTRAGAL PANEL WIDTH 26 518" MAX. D.L.O. 5-PT. LOCK 38" MAX. OA. UNIT WIDTH Toi 8" . O.A. JIT GHT 84 23/32" MAX. D.L.O. I� \ \ 1 . I /36" Q SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 24" 24" 10 1/16" 981 /8" MAX. 0.A. UNIT HEIGHT 84 23/32" MAX. D.L.O. 63 3/16" MAX. 0.A. UNIT WIDTH 20 5/8" MAX. D.L.O. 5-PT. LOCK SEE SHEET 6 DETAIL 1" FOR TYP. FRAME CORNER DETAIL ti INACTIVE ACTIVE T / 36° 1 \/ 1 24" 24" 24" 10 1/16" 1 MULTI -LOCK W/ SHOOT BOLTS ELEVATION SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 1 24" 24" 24" 10 1/16" 20 5/8" MAX. D.L.O. 5 -PT. LOCK 1 98 1/8" MAX. 0.A. UNIT HEIGHT ELEVATION i 32" 29 7/8" PANEL & ASTRAGAL PANEL WIDTH 32" MAX. OA. UNIT WIDTH t SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 84 23/32" MAX. D.L.O. / / /31" /4 1 24" 24" 24" 101/16" t REVISIONS: 8 1 1 W 0 tINUCT REVISED *owl)* with the-Florida altehiptanee Ne 7 D3/Y*0/ apfrstion Date FEA3ttZ Ell c��. 1•C , f Dadf P Central f+o 0 A CO D 0 o 111 • m • g • o In m 0co z_ N z > W a 13 o 0 W a z m W 03 ul 82 1/8" MAX. O.A. UNIT HEIGHT �- 751/8" MAX. O.A. UNIT WIDTH 26. MAX. D.L.O. L. 5 -PT. LOCK SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL INACTIVE 68 23/32" MAX. D.L.O. NINE 1 2 q 2 101/16" q MULTI -LOCK W/ SHOOT BOLTS 82 MA)� Ul HEI 5 -PT. LOCK 38" MAX. O.A. .UNIT WIDTH 26 5/8° MAX. D.L.O. 821 /8" MAX. O.A. UNIT HEIGHT . 68 23/32° MAX. D.L.O. i 63 3/16" MAX. O.A. UNIT WIDTH ---� -{ 20 5/8" MAX. D.L.O. r 5 -PT. LOCK SEE SHEET 6 DETAIL 9" FOR TYP. FRAME CORNER DETAIL 1 -_ • X\1\ 1/8" :.OA. VIT GHT Aft Q \ 0, 68 23/32" MAX. D.L.O. V j 1 36° / 0 \ INACTIVE \ 821 /8" MAX. O.A. UNIT HEIGHT . 68 23/32° MAX. D.L.O. i 63 3/16" MAX. O.A. UNIT WIDTH ---� -{ 20 5/8" MAX. D.L.O. r 5 -PT. LOCK SEE SHEET 6 DETAIL 9" FOR TYP. FRAME CORNER DETAIL MULTI -LOCK W/ SHOOT BOLTS ELEVATION SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 2 28" 101/16" ELEVATION 82 1/8" MAX. OA UNIT HEIGHT 32" MAX. OA. UNIT WIDTH 20 5/8" MAX. L D.L.O. i 28° 6 28" 10 1/16" t SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 68 23/32" MAX. D.L.O. 2 28" 10 1/16" 1 PRODUCT REVISIM godlM sal 1 .�! Mew N E,pifation Dade 8y WAWA Dad Division REVISIONS s 0 JELD -WEN WINDOWS AND DOORS O ") is o 0 0 m 0 a w Z g CO LU O L- Q z ca O 0 < CO ow m m ? m U 0 OP 2 0 Z a z ZJ 'Q m 0 F- g X\1\ 0, I V pc ACTIVE 36" / \ INACTIVE \ V MULTI -LOCK W/ SHOOT BOLTS ELEVATION SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 2 28" 101/16" ELEVATION 82 1/8" MAX. OA UNIT HEIGHT 32" MAX. OA. UNIT WIDTH 20 5/8" MAX. L D.L.O. i 28° 6 28" 10 1/16" t SEE SHEET 6 DETAIL "1" FOR TYP. FRAME CORNER DETAIL 68 23/32" MAX. D.L.O. 2 28" 10 1/16" 1 PRODUCT REVISIM godlM sal 1 .�! Mew N E,pifation Dade 8y WAWA Dad Division REVISIONS s 0 JELD -WEN WINDOWS AND DOORS O ") is o 0 0 m 0 a w Z g CO LU O L- Q z ca O 0 < CO ow m m ? m U 0 OP 2 0 Z a z ZJ 'Q m 0 F- g 6° MAX. TYP. @ -- HEAD & SILL 12.28" MAX. O.C. TYP. t TYP. P.T. BUCK BY OTHERS 6" TYP. @ HEAD & SILL 3° TYP. @ HEAD & SILL 0 .1p INACTIVE ACTIVE • / / ONO m FASTENERS AT HEAD & SILL THROUGH STRIKE PLATE INSTALLATION NOTES 1 6" MAX. TYP. OPTIONAL NAILING FIN (SEE INSTALLATION NOTE #6 ON THIS SHEET) I - 4-I 12.75° MAX. O.G. TYP. @ HEAD & SILL ANCHOR LAYOUT 75 1/8" x 98" 6" MAX. TYP. @ HEAD & SILL 12.28" MAX. O.C. TYP. 1. SHIM AS REQUIRED AT EACH SET OF INSTALLATION ANCHORS. MAXIMUM ALLOWABLE SHIM SPACE TO BE 1/4 ". SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. 2. FOR ANCHORING INTO CONCRETE OR MASONRY USE 1/4" DIAMETER ELCO TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1.1/4" MINIMUM EMBEDMENT WITH A 2 1/2° MINIMUM EDGE DISTANCE. 3. FOR ANCHORING INTO WOOD FRAMING USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT. 4. INSTALL ANCHORS AS SHOWN ON ANCHOR LAYOUTS AND SECTIONS. 5. LOAD BEARING SHIMS SHALL USED. 6. #8 X 1 5/8" ROOFING NAILS USED W/ OPT. NAIL FINS & DRIP CAP ARE NOT A SUBSTITUTION FOR USE AS AN INSTALLATION ANCHOR. IT IS SOLELY USED AS A LOCATOR. t \ 0 12.75" MAX. O.C. TYP. @ HEAD & SILL r "1 ANCHOR. LAYOUT 38" x98" 4° MAX. TYP. HEAD & SILL 1 14.35" MAX. O.C. TYP. INSTALLATION ANCHOR LOCATION TYP. 6" MAX. TYP. 6" TYP. @ HEAD & SILL 3" TYP. @ HEAD & SILL 0 / ACTIVE y / TYP. P.T. BUCK BY OTHERS 4 FASTENERS AT HEAD & SILL THROUGH STRIKE PLATE 6" MAX. TYP. @ HEAD & SILL I I 1 14.35° MAX. O.C. TYP. t�1 1 6" MAX. TYP. 11.75" MAX. O.C. TYP. @ HEAD & SILL ANCHOR LAYOUT 63 3/16" X 98 1/8" 1 6" MAX. TYP. t 1 t 10" MAX. 1 O.C. TYP. ANCHOR LAYOUT 32" x 98 1/8" with ituei3 111 Code 6 ^pal �O �, Date 1L Lik SOW Dadc raoct Control eivklou REVISIONS: ■ 1 I I 2 1 1 2 w O o 0 m Z ice Z� O 30 IT g Oz OE U OQ U 2 z 2 °o NMI co 0 co N F= w . . • \ / / /0. 1 t 10" MAX. 1 O.C. TYP. ANCHOR LAYOUT 32" x 98 1/8" with ituei3 111 Code 6 ^pal �O �, Date 1L Lik SOW Dadc raoct Control eivklou REVISIONS: ■ 1 I I 2 1 1 2 w O o 0 m Z ice Z� O 30 IT g Oz OE U OQ U 2 z 2 °o NMI co 0 co N F= w 6" MAX. TYP. @ HEAD & SILL 1 11.68" MAX. O.C. TYP. 1 TYP. P.T. BUCK BY OTHERS lr6" TYP. @ HEAD & SILL 3" TYP. @ HEAD & SILL �i / / INACTIVE ACTIVE FASTENERS AT HEAD & SILL THROUGH STRIKE PLATE I1 1 1 6" MAX. TYP. 1 OPTIONAL NAILING FIN (SEE INSTALLATION NOTE #6 ON SHEET 3) 12.75" MAX. O.C. TYP. @ HEAD & SILL ANCHOR LAYOUT 75 1/8" x 82 1/8" 12.75" MAX. O.C. TYP 6" MAX. TYP. @ HEAD & SILL 11.68" MAX. O.C. TYP. 6" MAX. TYP. �11 f fl it 1 ANCHOR LAYOUT 38" x 82 1/8" INSTALLATION ANCHOR LOCATION TYP. --►� �.,-- 3" TYP. @ HEAD & SILL 4" MAX. TYP HEAD & SILL 1 14" MAX. O.C. TYP. r INAC C . TYP. P.T. BUCK BY OTHERS FASTENERS AT HEAD & SILL THROUGH STRIKE PLATE 11.75" MAX. O.C. TYP. @ HEAD & SILL ANCHOR LAYOUT 63 1/8" x 82 1/8" 6" MAX. TYP. @ HEAD & SILL 14" MAX. O.C. TYP. 1 _ I 1.0" MAX. O.C. TYP. ANCHOR LAYOUT 32" x 82 1/8" 1 6" MAX. TYP. 1 PRINmer Ii V1S D yi ,►1t tL' o 111* Code �b l2, A Lraw -�` ay.e1 udc �trd Division REVISIONS: io a 2 1 1 w JELD -WEN WINDOWS AND DOORS co 0) 0 0 z W m } O 1c4 co 0 0 0 0 m O 0 x 0 z LL u, z z0 00 z 000 00 Z 0 z 3 CO e- N 0 0 a co O 0 0 co. W i�F g 1 g 0 9 1bj143 LL All 3/4" MIN. EDGE DIST. 2X BUCK BY OTHERS (TO BE ENGINEERED SEPARATELY) . .4 EXTERIOR INTERIOR .4 CONCRETE/MASONRY BY OTHERS L 1 1/2" MIN. EMBED. 1 1/4" MAX. SHIM SEE GLAZING DETAIL ON THIS SHEET (M VERTICAL SECTION MAX. UNIT HEIGHT (SEE CORRESPONDING ELEVATION IN SHEET 1 & 2) 5/ EXTERIOR FLANGE CONCRETE SEE GLAZING DETAIL ON THIS SHEET INTERIOR 3/4" MIN. EDGE DIST. OPTIONAL NAILING FIN (SEE INSTALLATION NOTE #6, SHEET 3) NOTE: TOP RAIL AND BOTTOM RAIL ARE COMPOSED OF SOLID .WESTERN PINE VENEER LAMINATED TO A KILN DRIED EDGE - AND -END GLUED CORE. LOCK AND HINGE STILES SHALL BE SOLID WESTERN PINE VENEER LAMINATED TO A TIMBERSTRAND CORE. STILES AND RAILS ARE 1.71875" THICK. TOP RAILS AND STILES ARE 4.625" WIDE. BOTTOM RAILS ARE 6.625° (168MM) WIDE. THE OPTIONAL BOTTOM RAIL IS 10.25° (260MM) WIDE. CLAD ALUMINUM ROLLFORM SURFACE IS .024" WALL THICKNESS. Q -LON TO BE SEALED BY SILICONE AT ASTRAGAL 2 1/2" MIN. r-- EDGE DIST. CONCRETE/MASONRY BY OTHERS • 4 1 1/4" MIN. EMBED. 1 VERTICAL SECTION FLANGE CONCRETE 4a 2X BUCK BY OTHERS (TO BE ENGINEERED • SEPARATELY) :4 EXTERIOR INTERIOR CONCRETE/MASONRY BY OTHERS 1/4" MAX. I SHIM 1 /_ SEE GLAZING DETAIL �� ON THIS SHEET VERTICAL SECTION FLANGE WI OPTIONAL DRIP CAP CONCRETE 1 1/2" MIN. EMBED. ALL PANELS WERE GLAZED WITH CARDINAL SEA -STORM 0.470" THICK OVERALL LAMINATED GLASS CONSISTING OF 3/16" ANNEALED GLASS - 0.095 SEA STORM INTERLAYER - 3/16" ANNEALED GLASS 0 INTERIOR GLAZING DETAIL I pt't S� Fbetda ���e► - a31Y•v l „tea BIZ DOOR OPENING GLAZING DESCRIPTION D.L.O. PANEL DIMENSIONS UP TO 75 1/8" x 98" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/16" ANNEALED GLASS 26 5/8 "x84 23/32" (Active): 35 7/8" x 98" (Inactive): 37 1/16" x 98" UP TO 63 3116" x 98 1/8" 3/16". ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/16" ANNEALED GLASS 20 5/8"x84 23/32" (Active): 29 7/8" x 98" (1 nactive): 32" x 98" UP TO 38" x 98" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/18 ANNEALED GLASS 26 5/8"x84 23/32" (Active): 35 7/8" x 98" UP TO 31 1/8" x 98 1/8" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/16" ANNEALED GLASS 20 5/8"x84 23/32" ' (Active): 29 7/8" x 98" UP TO 75 1 /8" x 82 1/8" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/16" ANNEALED GLASS 26 5/8 "x68 23/32" (Active): 35 7/8" x 82 1/8" (Inactive): 37 1/16" x 82 1/8" UP TO 63 3/16" x 82 1/8" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/16" ANNEALED GLASS 20 5/8"x68 23/32" (Acts*: 29 7/8" x 82 1/8" (Inactive): 32" x 82 1/8" UP TO 38" x 82 1/8" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/16" ANNEALED GLASS 26 5/8"x68 23/32' (Active): 35 7/8" x 82 1/8" UP TO 31 1/8" x 82 1/8" 3/16" ANNEALED GLASS + 0.095" SEA STORM INTERLAYER + 3/18" ANNEALED GLASS 20 5/8 "x68 23/32" (Active): 29 7/8" x 82 1/8" z 0 Io W 0 JELD -WEN WINDOWS AND DOORS O Z m 0 O 0 0 0 Z w m O Q 0 o 3/4" MIN. EDGE DIST. 1 1/2" MIN. EMBED. 2X BUCK BY OTHERS INTERIOR -LON TO BE SEALED BY SILICONE AT ASTRAGAL 1 1/2" MIN. EMBED. .4 d 4. 00----: INACTIVE ® ' I I� p Fi ' I L`�!! ACTIVE ion _am alimiliviiliill 111 III' Vi-------:--=-1111 =t '•r= i j — = r I, SEE GLAZING DETAIL, SHEET 5 IIV� i t 1 f"------___ 40 1/4" MAX. CONCRETE SHIM /MASONRY BY OTHERS e CONCRETE /MASONRY 4 � BY OTHERS SEE GLAZING DETAIL, SHEET 5 •'d1• • 2X BUCK BY OTHERS 3/4° MIN. EDGE DIST. TO BE USED WI DIRECT MOUNT SCREWS 1/4" MAX. SHIM HORIZONTAL SECTION HINGE WOOD 1 1/2" MIN. EMBED. 2X BUCK BY OTHERS • 3/4" MIN.° EDGE . DIST. 14 • CONCRETE INTERIOR ACTIVE /MASONRY - 1/4" MAX. BY OTHERS SHIM SEE GLAZING DETAIL, SHEET 5 EXTERIOR SINGLE DOOR (SEE MAX. UNIT WIDTH IN ELEVATION SHEET 1 & 2) HORIZONTAL SECTION LATCH AT JAMB WOOD EXTERIOR (OUTSWING DOORS) MAX. UNIT WIDTH (SEE CORRESPONDING ELEVATION IN SHEET 1 & 2) SECTION THORIZONTAL ASTRAGAL DETAIL 1 FRAME CORNER FASTENER DETAIL HORIZONTAL SECTION HINGE WOOD PRODUCT REVISED tiliatitmtying with the Florida Code tealltitnee o -03I''01 Expiration Date FA 11 l Mai Da fl_ er de D ivision FRAME CONSTRUCTION: THE WOOD FRAME IS 4 5/16° x 1 7/16" PONDEROSA PINE. THE FRAME METAL IS 2.26091 "x .921875" x .060" WALL EXTRUDED ALUMINUM. THE FRAME METAL IS SNAPPED ONTO THE WOOD JAMB WITH A LAP JOINT AT THE HEAD CORNERS AND SEALED WITH SILICONE (1199 DOW CORNING). EACH HEAD CORNER IS FASTENED WITH (3) #8 x 2" FLT. HD. PHL. SCREWS. AN ADDITIONAL #8 x 1" FLT. HD. PHL. SCREW IS APPLIED INTO THE SCREW BOSS OF THE ALUMINUM EXTRUSION AND A CORNER KEY .125" x 11/32" INTO THE SLOT OF THE ALUMINUM EXTRUSION TO COMPLETE THE CORNER. THE SILL IS ATTACHED THROUGH THE SIDE JAMB INTO THE SILL BASE WITH (3) #8 x 2" FLT. HD. PHL. SCREWS. AN ADDITIONAL #8 x 1" FLT. HD. PHL. SCREW IS APPLIED UP THROUGH THE SILL METAL INTO THE SCREW BOSE OF THE ALUMINUM SIDE JAMB EXTRUSION TO COMPLETE THE INSTALLATION. z 0 C 1 0 co 0 0 0 co 0 z W 0 0 0 0 z w m } m co 0 m 0 z 0 O 0 z z w m re 0 z 0 U v) 0 0 0.922" f - 2.261 "--� JAMB CLADDING 4.313" min 0.937" 0.805" 1.437" WOOD JAMB (HEAD /SIDE) (a 0.791° 0.625 1-4-1 GLASS STOP 1.310" CORNER KEY '313 1.310" 0.125" 4.605 " 11111' 1. 719" TOP RAIL '1\ 6.606" 1.719" BOTTOM RAIL 4.605" ND/ 1 1.719" LOCK/HINGE STILE 4.574" 0.438" TOP RAIL/STILE CLADDING 6.574" 0.438" T- BOTTOM RAIL CLADDING 0.542" -1 1.433" INACTIVE ASTRAGAL COVER 1.191" 0.542" ACTIVE ASTRAGAL COVER k . 1.157" 0.474° AJTRAGAL MULLION CAP -�' -1 1.750" 1.314" 0.628" SILL CA7 3.718" -►� OUTSWING SILL METAL 2.140" 0.891 DOOR SWEEP 0.435" 1.721° 1-*- OPTIONAL NAILFIN 4.125" -1 WOOD ASTRAGAL 1.522" 1-+-- c 1.884" I OPTIONAL DRIPCAP 2.063° 2.625 ".-H 0.996 °� 0.681" SILL GROMMET 1.062" SILL BASE I+--- 3.750 " -I.-1 1.1250 L U �--�0 1.240" 1.560" 0.375 "1 ® r SILL STRIKE PLATE 0.375" 3.250" O Oo 1'0'.875° HEAD STRIKE PLATE 1.416" $ 0.489" 0.260" WEATHERSTRIP 1 1.415" 1.51602" 1.180" 113 1.3478" f f 3.818" 0,787" ®I ROUNDBOLT STRIKE 0.775" 4.386" 0.695" 0.58- 8" WEATHERSTRIP 4.000° 4.000" TAI' ADJUSTABLE HINGE 0.157" (1,453" 199" 1.280" 0.820 1.831" 1 0.182" ACTIVE HARDWARE SINGLE & DOUBLE DOOR 623" 1.831° 0.241" INACTIVE HARDWARE t1.496" I 0.102" 0 1 1.772° 0.630 8.819" O 0.433" 3.976" 1.772" i 0.787" DUAL STRIKE PLATE NOTE: PANELS ARE CONSTRUCTED OF HINGE STILES (4.605" x 1.719 "), LOCK STILES (4.605" x 1.719 "), TOP RAIL (4.605" x 1.719 "), AND STANDARD BOTTOM RAIL (6.606° x 1.719 "), OPTIONAL BOTTOM RAIL (10.25° x 1.719 "). DOWELS ARE COATED WITH A WATER ACTIVATED ADHESIVE AND WATER IS APPLIED TO THE DOWELS PRIOR TO INSERTION INTO THE DOWEL HOLES. (SEE DETAIL "C") THE ASTRAGAL IS APPLIED TO THE INACTIVE STILE AFTER THE INACTIVE HARDWARE IS INSTALLED INTO THE INACTIVE STILE. DETAIL 2 PRODUCT REVISED as set¢ plying with iiiwriedik ilabithg eNs 7 a al * p raitan Date 1 L t .L� Dade 4seAi Whin w cc Io 0 0 0 m JELD -WEN WINDOWS AND DOORS 0 E O o o wz g w ow 00 m z f3� O 0U N 0 > • U O 2 Z J Z Q CO 0 0 U 0 50 ti Ce z w 1 a MATERIAL LIST MATERIAL LIST ITEM PART # DESCRIPTION MATERIAL 1 •SPD -161 ALUMINUM FRAME CLADDING - .060" WALL 6063 -T5 ALUM. 2 SPD -159 WOOD SIDE JAMB 3 SPD -164 WOOD HEAD JAMB 4 SPD -329 WOOD GLASS STOP WESTERN PINE 5 AC-74 FRAME CORNER KEY - 2 EA. (MITCHELL METALS) WESTERN PINE 6 N/A IMPACT RESISTANT ANNEALED LAMINATED GLASS (SEA STORM) SEE SHEET 5 7 N/A PRESSURE TREATED 2X BUCK (BY OTHERS) P.T. WOOD 8 N/A #8 X 1 5/8" ROOFING NAIL (USED W/ OPTIONAL NAIL FIN) 10 SPD -224 WOOD TOP RAIL 11 N/A 1/4" FRAME SHIM 12 SPD -226 WOOD 10 1/4" BOTTOM RAIL (OPTIONAL) WESTERN PINE 13 SPD -302 10 1/4" BOTTOM RAIL CLADDING - (HOMESHIELD) ALUMINUM 14 SPD -225 WOOD BOTTOM RAIL 15 SPD -228 WOOD LOCK STILE 16 SPD -228 WOOD HINGE STILE 17 SPD -300 TOP RAIL CLADDING - (HOMESHIELD) 18 SPD -301 BOTTOM RAIL CLADDING - (HOMESHIELD) ALUMINUM 19 SPD -304 STILE CLADDING - (HOMESHIELD) ALUMINUM 20 SPD -232 WOOD ASTRAGAL - (JELD -WEN MILLWORK) WESTERN PINE 21 SPD -162 ASTRAGAL MULLION CAP - (SAPA) 22 SPD -321 INACTIVE ASTRAGAL COVER - (SAPA) 23 SPD -320 ACTIVE ASTRAGAL COVER - (SAPA) 24 SPD -306 OUTSWING SILL METAL - (SAPA) 25 SPD -212 SILL CAP - .(CONNOLY) 26 SPD -213 SILL BASE - (CONNOLY) OAK 27 HLS -9000 INACTIVE MULTI -POINT HARDWARE - ( HOPPE) 28 HLS -9000 ACTIVE MULTI -POINT HARDWARE - ( HOPPE) 30 N/A INACTIVE HANDLE SET & ESCUTCHEON PLATE - ( HOPPE) COATED STEEL 31 N/A ROUNDBOLT STRIKE PLATE - ( HOPPE) 32 N/A DUAL STRIKE AND DEADBOLT PLATE - ( HOPPE) 33 N/A HEAD JAMB SHOOTBOLT STRIKE PLATE - ( HOPPE) ITEM PART # DESCRIPTION MATERIAL 34 N/A SILL SHOOTBOLT STRIKE PLATE - ( HOPPE) STAINLESS STEEL WESTERN PINE 35 N/A NOT USED WESTERN PINE 36 N/A Q -LON 650 WEATHERSTRIP SEALED W/ SILICONE - (SCHLEGEL) 37 N/A ARLOC WEATHERSTRIP BULB - (INTEK) 38 WA DOOR SWEEP - (ENDURA) 39 N/A 3/8" x 1/8" VHB TAPE 41 N/A ITEM USED BUT NOT SHOWN 42 N/A ITEM USED BUT NOTSHOWN WESTERN PINE 43 N/A SILL SHOOTBOLT GROMMET - (BRANDT) WOOD 44 N/A 1/2" x 4" DOWEL (CHICAGO DOWEL) POLY POLY POLY 3M BRASS STEEL POLY WOOD 45 N/A 4" ADJUSTABLE HINGE (SIMONSWERK) COATED STEEL 46 N/A ITEM USED BUT NOT SHOWN STEEL WESTERN PINE 47 N/A ITEM USED BUT NOT SHOWN WESTERN PINE 48 N/A ACTIVE HANDLE SET & ESCUTCHEON PLATE (HOPPE) COATED STEEL WESTERN PINE 49 N/A THUMBTURN (HOPPE) COATED STEEL ALUMINUM 50 N/A #1199 SEALANT (DOW CORNING) SEALANT 51 NIA 1° x 7/32" CROWN 18 GA. STAPLE, 6° 0.0 'PRODUCT NEVISED STEEL 52 N/A 53 N/A ALUMINUM 54 N/A #8 x 3" P.H.F.H. MTL. S /STL. SCREW I #8 x 2" P.H.F.H. MTL. SCREW (HOPPE) EiD 1Z- COATED STEEL STEEL #8 x 2" P.H.F.H. WOOD SCREW ALUMINUM 55 N/A #8 x 1" P.H.F.H. WOOD SCREW lea cJ STEEL COLOR MATCH STL. ALUMINUM 56 N/A #8 x 1" P.H.F.H. S /STL (ITEM USED BUT NOT SHOWN) STEEL ALUMINUM 57 N/A #8 x 3/4" P.H.F.H. WOOD SCREW COATED STEEL OAK 58 N/A #8 x 2 1/4" P.H.F.H. WOOD SCREW (ITEM USED BUT NOT SHOWN) COATED STEEL 59 N/A #10 WOOD SCREW (SELECT FOR 1 1/2" MIN. EMBED.) STEEL STAINLESS STEEL 60 N/A 1/4" ELCO TAPCON ANCHOR W/ 1 1/4" EMBED. STEEL STAINLESS STEEL 61 N/A #8 x 5/8" P.H.F.H. WOOD SCREW COATED STEEL 62 N/A #8 x 1 1/2° P.H.F.H. WOOD SCREW COATED STEEL COATED STEEL 63 AC-172 DRIPCAP 6063 -T5 ALUM. COATED STEEL 64 N/A FOLDING NAILING FLANGE - (AMESBURY) (OPTIONAL) POLY STAINLESS STEEL 65 NIA ITEM USED BUT NOT SHOWN WOOD 66 N/A ITEM USED BUT NOT SHOWN STEEL REVISIONS 1 i 1 1 0 0 JELD -WEN WINDOWS AND DOORS 3 M 1-; z 0 w w F. 0