Loading...
CC-11-1447Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 171880 Permit Number: CC -8 -11 -1447 Scheduled Inspection Date: April 04, 2012 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Wiegand & Annex Miami Shores, FL 33138 -0000 Project BARRY UNIVERSITY Contractor: EMERALD CONSTRUCTION CORPORATION Permit Type: Commercial Construction Inspection Type: Final Building Work Classification: Alteration Phone Number Parcel Number 1121360010160 -09 Phone: (954)241 -2583 Building Department Comments REMEDIATION FOR ASBESTOS ABATEMENT - NEW ACOUSTICAL CEILINGS Pas0:9" Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 169307. CREATED AS REINSPECTION FOR INSP- 168374. Work not complete and exceeds scope. Provide permits for room repairs and alterations not on plan. NB April 03, 2012 For Inspections please call: (305)762 -4949 Page 20 of 22 1M W...W5MMM 1MM-10:MM:0A MAM W ! A MAMA JO EE NNW W UNICIPAL REVISE PERMIT AND INSPECTION RECORD UNICIPAL NO.2012-002530 PROCESS NO M2011008470 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDING'S REQUIRED INSPECTIONS FIRE 0004 FIRE ALARM 20S FIRE FINAL 02/14/2012 FOLIO g 112136001016 /EIRE AL RN INIT 1 1 A DATE q . =WOW VAIMO.RIMIMA WWI rogNAk. Watt., a Miami -Dade County Building Department e- Permitting Search: fr)la ida (e. oV, Page 1 of 2 MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/30/2012 MUNICIPAL NO.2011 -055495 FOLIO: 1121360000050 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /REPAIRS LEGAL 36 52 41 40 AC SE1 /4 OF NE1 /4 LESS E35FT & LESS APPLICATION TYPE NEW 1 SQFT 1 UNITS 1 FLOORS OWNER NAME BARRY COLLEGE CONTRACTOR QUALIFIER PERMIT TYPE MUNICIPAL BLDG CATEGORIES 0001 MUNICIPAL GENERAL BUILDING DATE: 3/30/2012 PROCESS NUMBER: M2011008858 NEW'AMOUNT PAID 840.00 DERM 1 ASBESTOS REVI 175.00 DERM 1 UP FRONT FEE- 80.00 DERM 1 MIN COMM REV( 90.00 FIRE 80000 ALTERATIONS & 167.00 FIRE 1 FIRE UPFRONT 32.00 FIRE 1 SRI PLAN REVI 190.00 FIRE 1 SRI PLAN REVI 190.00 FRWK 2 1ST FIRE MINO 140.00 UPMU 1 UPFRONT FEE F 25.00 8/30/2011 12:13 BNZWEBI 181108300372 WEBIPAS 840.00 MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/30/2012 MUNICIPAL NO.2011 -055495 PROCESS NO. M2011008858 FOLIO: 1121360000050 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /REPAIRS REQUIRED INSPECTIONS INIT DATE FIRE 0001 FIRE INSPECTIONS RECOMMENDED 200 FIRE HYDRANTS 208 FIRE TCO INSPECTION 211 PRELIMINARY 209 FIRE FINAL � OUR-. MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/30/2012 MUNICIPAL NO.2011 -055495 PROCESS NO. M2011008858 FOLIO: 1121360000050 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /REPAIRS INSP INSP INSPECTION DISP RESULT INSP TYPE DATE 1 COMMENTS 1 CODE DATE INIT 20912/29/2011 00712/29/2011 POUGHC 20912/30/2011 04712 /30/2011 JABALIT 21912/30/2011 09012/30/2011 JABALIT 2090 /0 /0PLSECLMILTONWHNURON THE WAY. 0000 /0/0 http: / /egvsys .co.miami- dade.fl.us: 1608 /W W WSERV /ggvtBNZAW922.DIA ?PROS= M20... 3/30/2012 Miami -Dade County Building Department Page 2 of 2 MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/30/2012 MUNICIPAL NO.2011 -055495 PROCESS NO. M2011008858 FOLIO: 1121360000050 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /REPAIRS TO SCHEDULE A FIRE INSPECTION, PLEASE VISIT THE WEB AT WWN.MIAMIDADE.GOV/BUILDING. YOU WILL NEED TO PROVIDE YOUR TEN DIGIT MUNICIPAL NUMBER AND THREE DIGIT INSPECTION TYPE. THE INSPECTION TYPE CAN BE FOUND ON YOUR INSPECTION REQUIREMENTS AND RECORDS CARD NEXT TO THE REQUIRED INSPECTION. IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING AN INSPECTION, PLEASE CALL FIRE PREVENTION AT (786) 331 -4798. IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING A PLAN REVIEW, PLEASE CALL FIRE ENGINEERING AT (786) 315 -2771. BE ADVISED THIS IS NOT A PERMIT. PERMIT IS TO BE ISSUED BY YOUR CORRESPONDING MUNICIPAL BUILDING DEPARTMENT. Back to Main Menu BLDG Home Pale 1 BLDG Main Menu 1 BLDG Permit Menu 1 BLDG Plans Processing Menu 1 Inspection Types 1 Address Format Home 1 Using Our Site 1 About 1 Phone Directory 1 Privacy 1 Disclaimer E-mail your comments, questions and suggestions to Webmaster This page was last edited on: February 23, 2004 Web Site ® 2004 Miami -Dade County. Ati rights reserved. http: / /egvsys .co.miami- dade.fl.us:1608/W W WSERV /ggvt/BNZAW922.DIA ?PROS= M20... 3/30/2012 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit No. Master Permit No.C,C,I 9q Permit Type: BUILDING ROOFING Owner's Name (Fee Simple Titleholder) Barry University Phone # Owner's Address 11300 NE 2"' Ave City Miami Shores State FL Zip 33138 Tenant/Lessee Name Phone # Email Job Address (where the work is being done) //3o cD Abr. 411 Avg pal ,0 City Miami Shores Vill age County Miami -Dade Zip 331 b 1 FOLIO / PARCEL # 11- 2136 - 000 -0050 Is Building Historically Designated YES NO `V Flood Zone Contractor's Company Name rMerA!e Cetistruckli on Phone # 9S9 _ L4 o —as83 Contractor's Address /06 (o 4)/./ /r Co ter- f city A% /kind, -te.- dad' State fC . Zip 330 oq Qualifier Name Magrk v/ 1e_s Phone # °!S y — ay 1 — 6.1S B3 State Certificate or Registration No. c C7 (' 1551$ y 7,S Certificate of Competency No. Contact Phone E -mail Architect/Engineer's Name (if applicable) / ue •I SY vq 1 o u 441 43--.s. Phone # 15c1— %I- 606 Value of Work For this Permit $ ?o 0 O 0 Square / Linear Footage Of Work: H Ot O O C) S F Type of Work: ['Addition DAlteration ['New 3/Repair/Replace D Demolition Describe Work: (2 er,eZ1 4 4-) an ri 3-er 43bes os A 4-e,-) ei+ Y- A i e w 4c o -I i.,1 ce-; l,. f — % O ev5 6v2 jj�S �c�% t********,t,r * ***** r,wr*, *** ******, *** **** Fees * *a* *** **** **** * ** * * ** ** *** * ***** *,r*** *** Submittal Fee $ -&j l� Permit Fee $ 06100 CCF $ CO /CC $ Notary $ Scanning $ Double Fee $ Training/Education Fee $ Technology Fee $ Radon $ DPBR $ Bond $ Structural Review. $ Violation date: � 5`60.0 Total Fee Now Due $ Bonding Company's Name (if applicable) ■44/4 Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As 'a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issu- In the absence of such pond notice, the inspection will not be approves » • a reinspection fee will be charged Signature Owner or Agent The foregoing instrument was acknowledged before me this �2(gt day of 51,4 , 20 1'1 , by U/A CE %� LNA! n . , who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Signature Contractor The foregoing instrument was acknowledged before me this 2C) day of 1J1/ , 20 11 , by /I.-(k- 140 )CS , who is rsonally kno to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign- My Commission Expires: ,,,' Q t It Cuesta ' :MIJLE 041198 ?iR. rr sN� 09, 2014 >, • WWW.AARONNOTARY.can • ***************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** APPROVED BY Zoning Clerk checked 1111111 11111 1 1111 11111 11111 11111 11111 1111 1111 CFN 2011R0543319 NOTICE OF COMMENCEMENT : EC �DED F's 5/201 (12 RECORDED i_rE.'i5f�'Crii �,�e4P.2'y A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION HARVEY R1JV I H r CLERK OF COURT /I�� MIAMI -DACDE COUNTY? FLORIDA PERMIT N v I ' -1 TAX FOLIO NO. LAST PAGE STATE OF FLORIDA: COUNTY OF MIAMI-DADE: UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement 1. Legal description of property and street/address: 314021c. >lts1% _U31) NE. ANi _r AV AM t stare , r 3-¥c,1 • 2. Description of improvement: J x NE) — M WA1 01\1 3. Owner(s) name and address: f A ut \1 t ei t t ) I1300 N 'AA c.1-1 oft& c.1, 331 6 I Interest in- property: ame and address of fee simple titleholder: 4. Contractor's name and address: E I . L Ci Sf Olt_ .IOW ._I� __� ��R . -_ M1,i4bALk2__L _. 33.0A5____ 5. Surety: - (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ _ _ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may, be served as provided by Section 713.13(1)(a)7., Florida Statutes, N tme and address: 8. In addition to_himself. Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.1'3(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date `fed) ;_ ignatur of Owner Print Owner's Name Sworn to and subscribed before me thisZJ Srday of Notary Public__ Print Notary's Name My commission expires: 12:.01 -52 PACE 4 tl'U:: 2011 Prepared by Address: PERMIT #: CCL I T I I1 tl Miami Shores Viiage Building Department RECEIPT Fslalx01( _ ��►'' N����c�� it -raw_ 'R-Ai LS I, ' t,-tA DATE: 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 ntractor ❑ Owner ❑ Architect Picked up 2 sets of plans and (other) Address: \ \5C- — From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting pro ss. Acknowledged by: • k-L1 Piofc—L PERMIT CLERK INITIAL: RESUBMITTED DATE: PERMIT CLERK INITIAL: (L__ H "v/ Advanced Industrial Hygiene Services, Inc. Barry University 11300 NE 2nd Avenue Miami Shores, Florida All Facets of Industrial Hygiene Service July 6, 2011 Page 1 of 6 pages i Attn: Jeffrey J. Yao, Construction Manager Re: Supplemental Survey for Miscellaneous Asbestos- Containing Building Materials — "Wiegand Building ", 11300 NE 2nd Avenue, Miami Shores, FL AIHS Project # 1777 -038 Advanced Industrial Hygiene Services, Inc. (AIHS) is pleased to submit the following supplemental report for Asbestos- Containing Building Materials (ACBM) conducted on June 29, 2011 at the above - referenced facility. This survey was performed to identify additional miscellaneous ACM that may be included in the asbestos abatement project scheduled for the facility and is supplemental to AIHS report # 1777 -035 entitled "Wiegand Building Fire Alarm Upgrade ". Facility Description The subject facility is a two -story structure that house offices and classrooms/laboratories on each of the two floors. It has a central auditorium located off of the central lobby and a single story "Annex ". The scheduled asbestos abatement project deals with ACM located in the main building only and excludes the Annex. Sampling Strategy All accessible areas of the facility were inspected. Bulk sample specimens of materials suspected of containing asbestos were collected and submitted for analysis by Polarized Light Microscopy in conjunction with dispersion staining as outlined in 40 CFR; Part 63, Subpart F dated January 1987. Analysis will be conducted by Advanced Industrial Hygiene Services, Inc. AIHS, Inc. is accredited for asbestos fiber analysis through successful participation in the National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of section 206(d) of Title II of the USC Chapter 15, TSCA as stated in 40 CFR 763 dated April 30, 1987. 3611 NW 97th Avenue • Cooper City, Florida 33024 • Tel (954) 431 -9005 ♦ Fax (954) 431 -9202 www.aihsinc.com Survey for Miscellaneous ACM: "wiegand Building" 11300 NE 2vd Avenue Miami Shores, Florida 16\ IH July 6, 2011 AIHS Project # 1777 -038 Samples of miscellaneous materials suspected of containing asbestos were collected based on the following plan: Miscellaneous Materials: These include materials such as acoustical ceiling tiles, wallboard, joint compounds, resilient vinyl flooring, mastics, etc. (basically, anything that does not fall into the first two categories). Suspect miscellaneous materials were sampled in such a manner as to evaluate whether or not they contained asbestos. The number of samples collected of a given miscellaneous material was left to the discretion of the inspector. As a general rule, AIHS collects two to three samples of each distinct type of suspect miscellaneous material present. Findings Those suspect miscellaneous asbestos - containing materials that were present in the facility are listed as follows: Ceiling Materials Small areas of 1 X 1 ft2 acoustic ceiling tiles are present in the Chemical Stockroom. Representative samples were collected of the ceiling tiles and all were reported by the laboratory to contain no detectable quantities of asbestos. Flooring Materials Floor substrate consists of the poured concrete floor deck. Floor finishes consist of terrazzo (in the common areas such as main lobby and corridors), several types of adhered vinyl composition tiles (VCT) and carpet. Representative samples were collected of the VCT with mastic. Of these, the following floor finishes were reported by the laboratory to contain asbestos fibers: Flooring materials with asbestos in VCT and mastic: • 9 X 9" Vinyl Floor Tile & Mastic (Chemical Stock Room) • 9 X 9" Vinyl Floor Tile & Mastic (Biology Stock Room) • 9 X 9" Vinyl Floor Tile & Mastic (Room under Projection Room) • 1 X 1' Vinyl Floor Tile & Mastic (Projection Room) • Stored 1 X 1' Vinyl Floor Tile & Mastic (Projection Room) • 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Rooms 101, 102 & 103) • 1 X 1' Vinyl Floor Tile & Mastic (Room 146) • 1 X 1' Vinyl Floor Tile & Mastic (Room 151) • Bottom Layer 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 253) 2 Survey for Miscellaneous ACM: "Wiegand Building" 11300 NE 2°" Avenue Miami Shores, Florida 16\ I H Flooring materials with asbestos in mastic component only: • Vinyl Floor Tile Mastic (Basement Corridor under Auditorium) • Vinyl Floor Tile Mastic under Carpet (Room 254) July 6, 2011 AIHS Project # 1777 -038 HVAC System Components Asbestos fibers were previously identified in the off -white mastic on the insulated HVAC duct system. Thermal System Insulation (TSI) Materials No suspect TSI materials were observed in the facility. Surfacing Materials Asbestos fibers were previously identified in the spray - applied fireproofing insulation that is present on the structural steel components throughout the facility. This material can be observed above the ceiling grid. In addition, the acoustic plaster that is present in the lobby (on floors 1 & 2), projections room, room under projection room, alcove to anatomy lab and nurse's lounge was also previously identified to contain asbestos fibers. Miscellaneous Materials No additional suspect miscellaneous materials were observed in the renovation area. Assessments of ACM Asbestos containing building materials that were identified to be present and potentially impacted by the planned renovation activity are listed and assessed according to NESHAP criteria below. Fireproofing Insulation Material Description: Asbestos Content: Location: NESHAP Category: Estimated Quantity: Physical Condition: Light gray /tan fibrous material 15% Amosite Structural steel with overspray with loose debris on top of ceiling and other components throughout Friable Surfacing ACM Total Quantity Unknown Damaged 3 Survey for Miscellaneous ACM: "Wiegand Building"' 11300 NE 2°d Avenue Miami Shores, Florida Acoustic Ceiling Plaster Material Description: Asbestos Content: Location: NESHAP Category: Estimated Quantity: Physical Condition: 16\ I H w\s7 July 6, 2011 AIHS Project # 1777 -038 Soft light gray plaster with a white paint -like outer coating (black paint -like coating in auditorium projection room) 5% Chrysotile Central lobby ceiling (floors 1 & 2), auditorium projection room and room below, alcove to anatomy room and nurse's lounge Friable Surfacing ACM 3,500 ft2 Good Vinyl Composition Floor Tiles & Mastic Material Description: Miscellaneous 9 X 9 inch and 1 X 1 ft tiles with black mastic Asbestos Content: 1 -2 to 5% Chrysotile Location: 0 0 0 0 0 0 0 0 0 NESHAP Category: Estimated Quantity: Physical Condition: 9 X 9" Vinyl Floor Tile & Mastic (Chemical Stock Room) 9 X 9" Vinyl Floor Tile & Mastic (Biology Stock Room) 9 X 9" Vinyl Floor Tile & Mastic (Room under Projection Room) 1 X 1' Vinyl Floor Tile & Mastic (Projection Room) Stored 1 X 1' Vinyl Floor Tile & Mastic (Projection Room) 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Rooms 101, 102 & 103) 1 X 1' Vinyl Floor Tile & Mastic (Room 146) 1 X 1' Vinyl Floor Tile & Mastic (Room 151) Bottom Layer 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 253) Category I Non - Friable ACM Chemistry Stock Room - 550 ft2 Biology Stock Room — 400 ft2 Stairwell for above areas - 100 ft2 1st Floor under Projection Room — 240 ft2 2nd Floor Projection Room — 240 ft2 (plus pile of stored VCT) Room 101 — 135 ft2 Room 102 — 100 ft2 Room 103 —135 ft2 Room 146 — 100 ft2 Room 149 —112 ft2 Room 151 — 500 ft2 Good 4 Survey for Miscellaneous ACM: "Wiegand Building" 11300 NE 2°d Avenue Miami Shores, Florida Vinyl Composition Floor Tile Material Description: Asbestos Content: Location: 0 0 NESHAP Category: Estimated Quantity: Physical Condition: Duct Mastic Material Description: Asbestos Content: Location: NESHAP Category: Estimated Quantity: Physical Condition: (AF Mastic Black resinous material 5% Chrysotile July 6, 2011 AIRS Project # 1777 -038 Vinyl Floor Tile Mastic (Basement Corridor under Auditorium) Vinyl Floor Tile Mastic under Carpet (Room 254) Category I Non - Friable ACM Basement — hallway under Auditorium: 350 ft2 Room 254 — 750 ft2 Good Off -white caulk -like material 10% Chrysotile HVAC ducts throughout Category I Non - Friable ACM Unknown ( >260 ft2) Good Laboratory Performing Bulk Sample Analysis Advanced Industrial Hygiene Services, Inc. 3611 NW 97t Avenue Cooper City, Florida 33024 Telephone: (954) 431 -9005 On each page of the report of analysis section is the National Voluntary Laboratory Accreditation Program (NVLAP) laboratory identification number (101006 -0) that was assigned to the AIHS, Inc. laboratory upon entry into the NVLAP. A copy of the certificate of NVLAP accreditation as well as a certificate of The Scope of Accreditation is enclosed with this inspection report. AIRS, Inc. is licensed to conduct inspections for asbestos - containing materials in buildings under an Asbestos Consultants Business License (ZA 0000058) and is qualified by Bruce Marchette, CIH (Asbestos Consultants License # IA 0000041). 5 Survey for Miscellaneous ACM: "Wiegand Building" 11300 NE 2°" Avenue Miami Shores, Florida 146\ IH \97 July 6, 2011 AIRS Project # 1777 -038 Closing Remarks Prior to initiating any renovation or demolition project, Federal Law requires that the local EPA representative's office (The Department of Environmental Resource Management, 33 S.W. 2nd Avenue, Suite 9 -223, Miami, Florida) be notified in writing at least 10 working days prior to the onset of the project. The State Asbestos Coordinator's Office also requires a copy of the notification (address to State Asbestos Coordinator, State of Florida Environmental Regulation, 2600 Blare Stone Road, Tallahassee, Florida 32399 - 2400). Disclaimer This inspection report is the result of a diligent search of the renovation area for asbestos - containing building materials. The purpose of this inspection was to identify asbestos - containing materials that may require special treatment prior to proceeding with the planned renovation operation. Because this inspection was conducted prior to a planned renovation operation, only those suspect asbestos - containing materials expected to be disturbed as a result of the renovation activities were sampled and submitted to the laboratory for asbestos content. However comprehensive this inspection appears, it does not claim to have identified all of the asbestos - containing materials present in the facility. AIRS, Inc. is pleased to be of service. Please contact this office should you have any questions or comments concerning this report or any related matter. Enclosed: Table: Analytical Results Summary Consultant's credentials Laboratory credentials Appendix: AIHS Analytical Report - Log # 15954 6 Table: Analytical Results Summary TABLE 1 ASBESTOS ANALYTICAL RESULTS SUMMARY "Wiegand Building", Barry University, 11300 NE 2°d Avenue, Miami Shores, Florida Sample Number Location Description Asbestos NESHAP Classification 1777 - 15954 -1 & 2 Ceiling - Chem. Stck Rm 1 X 1 ft2 Ceiling Tiles NAD 6 1777 - 15954 -3 Floor - Chem. Stck Rm 9 X 9" VCT & Mastic 5% 4 1777 - 15954 -4 Floor — Biol. Stck Rm 9 X 9" VCT & Mastic 5% 4 1777 - 15954 -5 Floor — under Proj. Rm 9 X 9" VCT & Mastic 1 -2% 4 1777 - 15954 -6 Floor — Proj. Rm 1 X 1ft2 VCT & Mastic 5% 4 1777 - 15954-7 Projection Room 1 X 1fi2 VCT & Mastic 5% 4 1777 - 15954-8 Basement Corridor under Auditorium VCT Mastic 5% 4 1777 - 15954-9 to 11 Floor Rms 101, 102 & 103 1 X 1ft2 VCT & Mastic 5% 4 1777 - 15954-12 Floor — Room 146 1 X 1ft2 VCT & Mastic 5% 4 1777 - 15954-13 Floor —Room 149 1 X 1fi2 VCT & Mastic NAD 6 1777 - 15954 -14 Floor Room 151 1 X 1ft2 VCT & Mastic 5% 4 1777- 15954 -15 & 16 Floor — Rms 251 & 253 1 X 1ff.2 VCT & Mastic NAD 6 1777 - 15954 -17 Floor —Room 253 under Carpet 1 X 1f12 VCT & Mastic 5% 4 1777 - 15954-18 Floor — Room 254 VCT Mastic 5% 4 1777 - 15954-19 to 23 Interior Walls Vinyl Base & Mastic NAD 6 KEY: NESHAP Classification 1. Friable Surfacing ACM 2. Friable Thermal System ACM 3. Friable Miscellaneous ACM 4. Category I Non - Friable ACBM 5. Category II Non - Friable ACBM 6. Non -ACM NOTES: NAD No Asbestos Detected Asbestos Licenses AC* 4554471 STATE OFFLORIDA DEPARTMENT OF MINUS LICENSINQSVSNIOj�TAL REGULATION T1 SEQ# L09083103074 DATE BATCH NUMBER LICENSE NBR 08/31/2009 090112762 ZA0000058 The ASBESTOS BUSINESS ORGANIZATION Named below IS LICENSED Under the provisions of Chapter 469 FS. Expiration date: NOV 30, 2011 ADVANCED INDUSTRIAL HYGIENE SERVICES INC BRUCE E. MARCHETTE MIAMI 2 AVE FL 33129 CHARLIE CRIST GOVERNOR DISPLAY AS REQUIRED BY LAW CHARLES W. DRAGO SECRETARY Laboratory Accreditation United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO /IEC 17025:2005 NVLAP LAB CODE: 101006 -0 Advanced Industrial Hygiene Services, Inc. Miami, FL is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for. BULK ASBESTOS FIBER ANALYSIS This laboratory is accredited in accordance with the recognized International Standard ISQ/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO - ILAC -IAF Communique dated January 2009). 4 "Nos‘ 2011 -04-01 through 2012 -03 -31 Effective Effective dates �° For the National In ute of Standards and Technology er, oa NVLAP -01C (REV. 2009-01-28) A Hygiene Services, Inc. Advanced Industrial Hygi , �"I All Facets of Industrial Hygiene Service '17r Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 1 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CHI Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -1: 1 X 1' Acoustic Ceiling Tile (Chemical Stock Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Off -white compacted fibrous material with a white paint -like outer coating No No 70% fibrous glass /mineral wool 15% cellulose fibers 10% mineral/resin binders & glass shots 5% paint Fibrous glass fibers isotropic, no sign of elongation, no birefringence, non - pleochroic Cellulose fibers anisotropic, ( +) sign of elongation, birefringence: medium, pleochroic, incomplete extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 159541 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NISI National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97th Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. 3611 NW 97th Avenue ♦ Cooper City, Florida 33024 ♦ Tel (954) 431-9005 FAX (954) 431 -9202 www.aihsinc.com Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 2 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation. Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -2: 1 X 1' Acoustic Ceiling Tile (Chemical Stock Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Off -white compacted fibrous material with a white paint -like outer coating No No 70% fibrous glass /mineral wool 15% cellulose fibers 10% mineral/resin binders & glass shots 5% paint Fibrous glass fibers isotropic, no sign of elongation, no birefringence, non - pleochroic Cellulose fibers anisotropic, ( +) sign of elongation, birefringence: medium, pleochroic, incomplete extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -2 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NISI National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006-0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97th Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. I H Account # 1777 • Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 3 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777- 15954 -3: 9 X 9" Vinyl Floor Tile & Mastic (Chemical Stock Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains. 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Black & gray vinyl composition tiles with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tie) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non- pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777- 15954 -3 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006-0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 971h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. les\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 4 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -4: 9 X 9" Vinyl Floor Tile & Mastic (Biology Stock Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Black & gray vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tiile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 159544 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. /A\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 5 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -5: 9 X 9" Vinyl Floor Tile & Mastic (Room under Projection Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Black vinyl composition tile with black mastic residue Yes No 1 -2% 1 -2% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 48-49% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954-5 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4-82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97" Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. s\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 6 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -6: 1 X 1' Vinyl Floor Tile & Mastic (Projection Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Dark brown marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysolite fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non- pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -6 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97" Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. ss\. I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 7 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -7: Stored 1 X 1' Vinyl Floor Tile & Mastic (Projection Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Olive green marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non- pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -7 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4- 82-020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97'h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 8 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -8: 1 X 1' Vinyl Floor Tile & Mastic (Basement Corridor under Auditorium) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Off -white marbled vinyl composition tile with brown and black mastics Yes (in black mastic component) No <1% 5% CHRYSOTILE Asbestos (in black mastic component) None detected 50% vinyl/mineral binders 45% mineral granules 5% bituminous & glue resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777-15954-8 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program ( NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4-82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, (4J, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. /A I H v/. Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 9 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -9: 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 101) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Olive green marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954-9 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 6001M4-82- 020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006-0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`" Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. /A\ IH Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 10 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -10: 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 102) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Olive green marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, RI. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777-15954-10 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4-82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 976 Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. 16\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 11 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777- 15954 -11: 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 103) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Olive green marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -11 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. 4164I 1"/' Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL/11 Page 12 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -12: 1 X 1' Vinyl Floor Tile & Mastic (Room 146) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Olive green marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, RI. y: 1.559, RI. a: 1.548, birefringence: low, non- pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -12 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006-0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, .,..,� 1, / Bruce Marchette, CIH Authorized Signatory AIRS, Inc. la\H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Date: 05 /JUL /11 Page 13 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Attn: Jefferey Yao Collected by: Bruce Marchette, CIH Sample Received: 29 /JUN /11 Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777- 15954 -13: 1 X 1' Vinyl Floor Tile & Mastic (Room 149) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Tan marbled vinyl composition tile with brown and black mastics No No None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous & glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -13 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. 146\ I H v/. Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 14 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -14: 1 X 1' Vinyl Floor Tile & Mastic (Room 151) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Olive green marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C Tbis analysis report is valid for sample # 1777 - 15954 -14 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`h Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. 16\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 15 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -15: 1 X 1' Vinyl Floor Tile & Mastic (Room 251) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Double layer gray and turquoise vinyl composition tiles with yellow mastic No No None detected 50% vinyl/mineral binders 45% mineral granules 5% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -15 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006-0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97" Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 16 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777- 15954 -16: 1 X 1' Vinyl Floor Tile & Mastic (Room 253) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Gray marbled vinyl composition tile with yellow mastic No No None detected 50% vinyl/mineral binders 45% mineral granules 5% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777- 15954 -16 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97* Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. N\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Date: 05 /JUL /11 Page 17 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Attn: Jefferey Yao Collected by: Bruce Marchette, CIH Sample Received: 29 /JUN /11 Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -17: Bottom Layer 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 253) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains: 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Tan marbled vinyl composition tile with black mastic residue Yes No 5% 5% CHRYSOTILE Asbestos (in tile) 5% CHRYSOTILE Asbestos (in mastic) None detected 45% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954-17 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NISI National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4-82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97th Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. s\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 18 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777- 15954 -18: 1 X 1' Vinyl Floor Tile & Mastic under Carpet (Room 254) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Total Asbestos Content: 5. Sample Contains. 6. Non - Asbestos Fibers Present: 7. Non - Fibrous Material Present: Tan marbled vinyl composition tile with black mastic residue Yes (in black mastic component) No <1% 5% CHRYSOTILE Asbestos (in black mastic component) None detected 50% vinyl/mineral binders 45% mineral granules 5% bituminous resins (mastic) Chrysotile fibers anisotropic, ( +) sign of elongation, R.I. y: 1.559, R.I. a: 1.548, birefringence: low, non - pleochroic, parallel extinction Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777- 15954 -18 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NISI National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" ( NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97d' Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. 4 1^ b\, I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 19 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -19: Vinyl Base & Mastic (Chemical Stock Room) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Black vinyl base with brown mastic No No None detected 95% vinyl sheeting 5% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -19 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006-0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97a' Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. 1 s\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN /11 Date: 05 /JUL /11 Page 20 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -20: Vinyl Base & Mastic (Room 146) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Black vinyl base with brown mastic No No None detected 90% vinyl sheeting 10% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -20 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97th Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, F_. Bruce Marchette, CIH Authorized Signatory AIHS, Inc. a iss.\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL/11 Page 21 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -21: Vinyl Base & Mastic (Room 149) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Cream vinyl base with off -white mastic No No None detected 98% vinyl sheeting 2% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -21 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`s Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIRS, Inc. 1 16\ I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 22 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CIH Sample Analyzed: 05 /JUL /11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -22: Vinyl Base & Mastic (Room 150) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Black vinyl base with off -white mastic No No None detected 97% vinyl sheeting 3% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 15954 -22 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method: EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 97`' Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. JI 4 I H Account # 1777 Project # 038 Barry University 11300 NE 2nd Avenue Miami Shores, Florida 33161 Attn: Jefferey Yao Sample Received: 29 /JUN / 11 Date: 05 /JUL /11 Page 23 of 23 pages Sample Log # 15954 NVLAP Lab Code 101006 -0 Collected by: Bruce Marchette, CHI Sample Analyzed: 05 /JUL/ 11 Sample Designation: Bulk Sample Submitted for Analysis "Wiegand Building — Miscellaneous Materials" Analytical Results: ASBESTOS CONTENT Sample # 1777 - 15954 -23: Vinyl Base & Mastic (Room 253) 1. Sample Appearance: 2. Was Asbestos Detected? 3. Is Sample Homogeneous? 4. Non - Asbestos Fibers Present: 5. Non - Fibrous Material Present: Gray vinyl base with yellow/brown mastic No No None detected 90% vinyl sheeting 10% glue resins (mastic) Lab workstation temperature: 25 °C This analysis report is valid for sample # 1777 - 1595423 only. Advanced Industrial Hygiene Services, Inc is accredited for asbestos fiber analysis through participation in the NIST National Voluntary Laboratory Accreditation Program (NVLAP) and meets the requirements of 40 CFR Part 763.87, Vol. 52, No. 210 Dated Friday, October 30, 1987. Accreditation renewal date: March 31, 2012. Analytical Method EPA- 600/M4 -82 -020 "Interim Method for the Determination of Asbestos in Bulk Insulation Samples" & EPA/600/R- 93/116: "Method for the Determination of Asbestos in Bulk Building Materials" (NVLAP Lab Code 101006 -0). Analyzed by: Bruce Marchette, CIH Laboratory: Advanced Industrial Hygiene Services, Inc., 3611 NW 974' Avenue, Cooper City, Florida 33024, Telephone: (954) 431 -9005 This report shall not be reproduced except in full, without the written approval of Advanced Industrial Hygiene Services, Inc. Furthermore, this report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Respectfully Submitted, Bruce Marchette, CIH Authorized Signatory AIHS, Inc. Advanced Industrial Hygiene Services, Inc. All facets of Industrial Hygiene Service Chain -of- Custody Record .wll NW yr-AM= Tel: (934) 431 www.aibs.cc • cooper Lay • monde -9005 • Fax: (954) 431-9202 • cmail4taihsinc.com !SUM Page 1 of 1 page I - Comments ACBM Date 2011 29, 2011 Time 17:30 Project Name or Number: 1777 -038 Project Location: Wiegand Building itif(/// X Analyses Requested (�'__ Suspect Client Name: Barry University Sample Description/Type (check one) Sample Volume or Area Number C�° Item # Semple # Date Time Air Bulk Swab Other (specify) 1777- 15954 1 -23 tune 29, 2011 4 X n/a 23 5 Person Responsible for Sample: Bruce Marchette, CIH Transfer # Item # Transfers Relinquished Date 2011 29, 2011 Time 17:30 Accepted by: /i� . / J' �y �`ti�`� '�'�L Date leas 29, 2011 Time 17:30 1 1777- 15954 (�'__ Remarks: Limited pre - renovation survey for ACBM 2 3 4 5 laia 1 AAt Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 k \4 � VV\C* ?r pCw \;-� NOV 1 2011 BY JCX6 Permit No. Master Permit No.0 — yH-4- - 2yI^- 25-P1 Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): �1� y UL 1 U Z( { Phone #: Address: \ , 300 L aue , City: \D A: ` \Ct- State: L Tenant/Lessee Name: Email: JOB ADDRESS: City: Folio/Parcel #: \ (y \ 3to f qoe Miami Shores County: Miami Dade zip: 33 t (of Phone #: UDOkr \< • r i rl ®N.) Zip: 3\ 1 Is the Building Historically Designated: Yes NO ((flood Zone: / �-Vrr CONTRACTOR: Company Name: 6 Im e . \a �}Ir\S r (LtC Or1 Phone#: qs(4 - L - ZS ' Address: ► ■ City: \c kkA,f1 Qualifier Name: State: tiLv-b\es Zip: 3 300ct Phone #: 1 State Certificatio or Registration #: CC \ S 13 ✓1�� °Certificate of Competency #: Contact Phone #: J \ -2.-Sg3 Email Address: Q(\C 1/4,(v1PdrG I DESIGNER: Architect/Engineer. C vi\ \ S f 1 CAD Value of Work for this Permit: $ o3� 00 Square/Linear Footage of Work: Type of Work: Addition Alteration Description of Work: 't u.c 'I Phone# 4-- Clo CAb UNew 0 ORepair/Replace ODemolition . * * ** *** * ** ** x+ x**************** * * ****** Fees * *** ****** ** ********+ + x+ x+ x****+s******+x******** Submittal Fee $ permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Gx CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Con :CV Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature . D�' /, d24 Signature Owner or Agentp� Contractor The foregoing instrument was acknowledged before me this ✓' " The forego ng instrument was acknowledged before me this \ " day of t) V L20 IL, by U 1SJ 4 1S(' day of r , 20 1 , by ' " K. VA VOA, �1YS whq,�personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Ex NOTARY PUBLIC: Sign: Print: c6cAcz My Commission Expires: ,tie Gilds Pored .COMMiSSICry4 .. / 4g56 , 2011 *s< s=* *x• ************ **+ x**m ****** ******m *+ xx: ***+ x********m+ x+ x*** ****** ********** ***+a********* **a: tim m APPROVED BY Plans Examiner Zoning Structural Review Clerk' (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) (pi II t — COLD4- 0t,01111[Aitifil' Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit Ty :BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): ,� re 0. ) th Address: f /c� ®, 4/6- � 02.).1 02.).1 City: /97/4 /Y79 .L State: Z1. Zip: 331i Tenant/Lessee Name: � Phone #: Email: 4 SEP 2 2011 Permit No.C,C `H�� Master Permit No. Phone#: ° r c c7 -39)-5 JOB ADDRESS: /214::10 de t City: Miami Shores County: -J - , *116 Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes CONTRACTOR: Company Name: Flood Zone: Address: /® irk, Iv/ % 149‘,/e4" // City: State: G P Zip: Phone #: QS/ et fer--4 Qualifier Name: State Certification or Registration #: (� ! /� /��/ Certificate of Competency #: Email Address: �ijL� ��Yte LC �C��' CQ`it Contact Phone #:' S9 l -01.58 — DESIGNER: Architectfliig'ei': Phone #: Value of Work Type of Wo Descrip t: $ 100 ®*EIN Square/Linear Footage of Work: ■, 9 a ❑Alteration ❑New epair/Replace ❑Demolition r Work:: / --4 dnfort : dfr2E9se¢ .ev) rc49wet ®e.... -®f IA- 6004, 014e-0-) 4th N( o- te I iOr c X ZS . ******** * * * *** * * * * * ********* * * *** * * * *** Fees**** ********* ** * * * *** * * * * ** * * *** *** * * * * * * * ** Submi Fee $ Permit Fee $ J v CCF $ CO /CC $ scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ TOTAL FEE NOW DUE $ iNJ Cat -- yVia Z. Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State — Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this 1 day of Sk-` , % , 20 11 by M1Uo q(.411X S wtio is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My.Commission Expires: 11 Signature vv\ Contractor The foregoing instrument was acknowledged before e this day of 0 %11 , by /% /- wh . s ersonall _ to me or who has produced as identification and who did take an oath. NOTARY PUB My Commission Expirel0.4%,, Jonathan Cuesta 0QMMISSION #EE 041198 ,,�,��°, EXPIRES; NOV. 09, 2014 * • x• x****** ****** a:+ x+ x***** x:: a****x:m **************** ******+ hWa**MIAMONNOWN u*** APPROVED BY ' /,63 Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) I lit co/0)41' Permit No: 11 -1447 Job Name: September 21, 2011 Miami Shores Viiiage Building Department Building Critique Sheet Revision 1) Provide approval from Miami Dade County Fire Dept. 2) Provide approval from Miami Dade County DERM. 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 Miami Shores Viiiage Building Department RECEIPT PERMIT It:C ' !I-- ! DATE: 1, 4retge Ni Contractor ❑ Owner ❑ Architect er) 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Tivc, From the building department on this date in miler to have corrections done to plans And /or get County stamps. I understand that t plans need to be brought back to Miami Shores Village Building D partme t to con n permitting process. Acknowledged by: PERMIT CLERK INITIAL: PlattA broO bC)fr-- RESUBMITTED DATE: 10 W lH/\ 101 Oe" 11) lee) Teoeweol PERMIT CLERK INITIAL:, s �` Permit No: 11-1447 Job Name: October 20, 2011 Miami Shores Viiiage Building Department Building Critique Sheet Revision 2nd 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 1) Provide approval from Miami Dade County Fire Dept. 2) Provide approval from Miami Dade County DERM. 3) Provide an electrical plan for the revised floor plan. 4) Identify the level of alteration. This is no longer a repair. Identify the size of the altered /moved doors. Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 nldlu CAW 4 GA 3 VOS 5oIS2 Mss. 9h4 YacPc_ }hag �� , ,, / \\iv st4 -@zAm Y «ion 100t1AB di ;-o bey a e / . !fel) 5s)1,11 n ho i i -plc.- .n at bitia. Miami Shores VllIage Building Department RECEIPT PERMIT #: Cc-11 ") 9 r7 DATE: I, Q Contractor ❑ owner ❑ Architect Picked up 2 sets of plans and (other) rtax. Address: 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Depart, ent to co, inue permitting process. Acknowledged by: — I PERMIT CLERK INITIAL: _44 RESUBMITTED DATE: PERMIT CLERK INITIAL: MANUEL SYNALOVSKI ASSOCIATES, LLC 1800 Eller Drive, Suite 500 • Fort Lauderdale, FL 33316 • Telephone 954.961.6806 • Facsimile 954.961.6807 September 8, 2011 Norm Bruhn, Building Official Village of Miami Shores 10050 NE Second Avenue Miami Shores, FL 33138 RE: Barry University - Wiegand Center Permit No. CC -8 -11 -1389 Mr. Bruhn: As the Architect of Record we offer the following as a summary of the scope of the work for the project at Barry University's Wiegand Center. 1. Asbestos Abatement of Roof Steel Structural Fireproofing, some Vinyl Composition Tile and Ductwork Mastic. 2. Re- Fireproof the steel roof members utilizing Cafco Blazeshield II. 3. Reinstall Vinyl Composition Tile in abated areas. 4. Reinstall ductwork removed throughout the building. 5. Reinstall acoustical tile ceilings. 6. Reinstall /upgrade lighting. Please do not hesitate to contact this office should you have any questions or concems with the above. Respectfully. Manuel Synalovvki-, AIA, Managing Partner FL Lic. #11,628 MANUEL SYNALOVSKI ASSOCIATES, LLC a texture.x r d n Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 tAz Inspection Number: INSP- 168134 Permit Number: MC -8 -11 -1448 Scheduled Inspection Date: December 28, 2011 Inspector: Perez, JanPierre Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Wiegand & Annex Miami Shores, FL 33138 -0000 Project: BARRY UNIVERSITY Contractor: WAYNE GROUP & SERVICES INC Permit Type: Mechanical - Commercial Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1121360010160 -09 Phone: (954)242 -9806 Building Department Comments REPLACE DUCTWORK Passed u�, Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 163080. need T & B report & check duct detector jpp December 28, 2011 For Inspections please call: (305)762 -4949 Page 22 of 28 December 21 , 2011 Mechanical Inspector City of Miami Shores RE: Bally University - W' Band Post-Asbestos Remedial Work Dear Sir. Please be informed that it is acceptable to Delta G that no Test and Balance be performed at the . time of the project completion. No new mechanical equipment was installed as part of this project. As per owner discretion, a T&B rniyh,t be performed at a later time upon negafive feedbacks fro m the fading occupants_ Should you have any quesfions regarding the above responses: please contact the office at (954) 527 -1112 or by fax at (954) 524-7505. Sincerely. .t�����VILLA 40 p. P '_ • -1/1 1 Mortdlarclazok .E. G�`�._. Mectfinatiggirte V * • sAP ®••'� s %flit It too 707 NE 3rd Avenue, Fort Laudeniale, FL-, 33304 Telephone; (954) 527 -1112 Fa'c (954) 514-7