Loading...
PL-11-1709Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 164582 Scheduled Inspection Date: April 20, 2012 Inspector: Hernandez, Rafael Permit Number: PL -9 -11 -1709 Owner: LEE, PATRICK & LESLIE Job Address: 1122 NE 97 Street Miami Shores, FL 33138- Project: <NONE> Contractor: SUBURBAN PROPANE Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Gas Phone Number Parcel Number 1132050170170 Phone: 305 - 891 -8393 Building Department Comments SET 2 LP GAS TANKS HOOK UP TO EXISTING SERVICE Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments April 19, 2012 For Inspections please call: (305)762 -4949 Page 1 of 11 Miami Shores Village -"Sum' Building Department (9'-di '�"' t 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: 305 ( ) ( ) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit Type: PLUMBING �> Owner's Name (Fee Simple Titleholder) e.. sr.)/ le°e Phone # 761-C / 416 'A Owner's Address 1 a a 'VL g 7 Y4 SI- City /97/47 ii S'h State Zip 3 3 /7 e Permit No.V1 t 1/09 Master Permit No. Tenant/Lessee Name Email Phone # n411 Job Address (where the work is being done) — 'J /2 7 City Miami Shores Village FOLIO / PARCEL # Is Building Historically Designated YES NO Flood Zone County Miami -Dade Zip 33/3 r Contractor's Company Name eV &e,".6 ``� ,O# Contractor's Address A- Phone # 3 G b' - 00 �3 City 7V ' M0 -.4Y/ State - Qualifier Name SoL i O,,� �1 /2/9— Zip 531.6X Phone # 36 ,r 2 S 3C State Certificate or Registration No. Certificate of Competency No. Contact Phone Architect/Engineer's Name (if applicable) Value of Work For this Permit $ E -mail Phone # goo ( Square / Linear Footage Of Work: Type of Work: DAddition DAlteration ❑New ❑ Re.air/Re Describe Work: g- 1161 sffiP. • 3rni f ' (bee Arr. inrr/A Submittal Fee $ Notary $ Scanning $ Radon $ Double Fee $ Structural Review. $ .e® Permit Fee $ Training/Education Fee $ CCF $ CO /CC $ DPBR $ Violation date: Technology Fee $ Bond $ Total Fee Now Due $ See Reverse side -3 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's' Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be a.proved and a r %nspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of L , i ,..y Lsst who ' • ersonally known to e or who has produced NOTARY P Sign: Prin My Co ► ss +n Signature Contractor The foregoing instrument was acknowledged before me this / , da As identification and who did take an oath. APPROVED BY > • (Revised 07 /10 /07)(Revised 06/10/2009) rA 20 J, by 56144 ,2'1 /ern who is personally known to or who has produced as identification and who did ta, an . ath. NOTARY LIC: * ION EEi 0 EXPIRES: June 15, 2015 ome, Bombi Thru Bum Nay Services <'.F. "1 Plans Examiner Zoning Engineer Clerk checked e.° IC:PC:44 eek Ole 0;5 04- Suburban Propane 1491 N. E. 130th Street N. Miami, FL 33161 Cualifier ,:ob Address L.nEest Run t_J 6 Wag A/L--- 971-0 s-11- )72 /-rn s 1-71ext4 c ooa AV--0 wv 1 Qualifier Job Address l.:)ngest Run BTU's Suburban Propane 1491 N. E. 130th Street N. Miami, FL 33161 3 0 5 Ne- 7 *A 5'A /471i1 6 AiLlyza.4 9 • ‘k\v N.E. 677711 STREET . 4'. • • ••.1 t • ••• t•ttt:• ....At • • ••• ••••....",••■•,70.• • 4., • • • t. • s • • • • • • t .• • •,••17 ohan. Paweamilta.;-- • et >2. ' '' • •••• " ; .... . •4•,.."7::••• • • ••••—•r•Wit7t.7.....v'.....:::: •• 47; Suburban Propane 1491 N. E. 130th Street N. Miami, FL 33161 3 022.143,4 Qualifier Address /-/VV. A/2' 97 71-17-S-/L 711friarit gest Run Ad, Total BTU's V7ftao f,0a 10/4e) .na arms! Parkway frf FJ/111, IrEs tar 3 • ft= 1st =Wm 17-5, THIS VESSEL IS DESIGNED FOR THE STORAGE OF LIQUEFIED PETROLEUM GAS ONLY OME SLOT r1+8r�' ,NAT'. BD. SERIAL N0. 0 HINGE C.� a •P I_ Y. , •��. 0 e, ASP (�', CERTIFIED BY: AMERICAN WELDING &TANK HARSCO CORPORATION GAS & FLUID CONTROL GROUP JESUP. OEOROIA•BLOOMFIELD, IOWA. SALT LAKE CITY. UTAH- FREMONT. OHO • : °F is F -`1 MAX. ALLOW. WORKING PRESS.1 250 aSI AT 1 U r '4.� w �MT�,.F AT 1� P5! PLANT NO._ ICRN NO. L- 4704.50 - 1 SERIAL NO. I A 1 YEAR BUILT 120 L 11 .r .. •�• Rrz OUTSIDE • LENGTH HEAD T 1 . 88 I IN. DIA 24 IN. W. SO. FT. GALS. 0 3 .139 11N. SHELL .140 L� 2 GROUNDBOVE I BS-AP 1 SURFA 38 LISTED CONTAINER 1� ASSEMBLY FOR LP GAS HEAD D.R. 21 -4 � �T CAPACITY 120 O THIS CONTAINER SHALL NOT CONTAIN A PRODUCT HAVING A VAPOR PRESSURE IN EXCESS OF 215 PSI AT 100.F. 12 �/ 1/4 I DIP TUBE LENGTH -80% FULL © 40 DEG. F. D.T = 7.1 IN. FITTING LAYOUT DATA PLATE DETAIL TOP VIEW (A - 12009) GENERAL NOTES: 1. UFTNG LUGS DESIGNED FOR TOTAL LIFTING WEIGHT OF ate. 2. TOTAL EMPTY WEIGHT IS. 3. AU. DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED. 4. COMPLETE TANK DRIED TO REMOVE ALL MOISTURE. 5. NOTE DELETED 6. EXTERIOR OF TANK TO BE GRIT BLASTED. 7. PAINT PER SHOP ORDER. 8. PRESSURE TANK WITH DRY AIR FOR SHIPMENT. 8. DIMENSIONS ARE SU i ECT TO CHANGE WITH OUT NOTICE ( NON -PRESSURE RETAINING COMPONENTS ONLY) 10. THREADS OF ALL FITTINGS TO BE COATED WITH COMPOUND SUITABLE FOR USE WITH LP GAS. 11. FLOAT GAUGE TO BE INSTALLED WITH FLOAT ARM 45.OFF AL cENrERLINE of TAN LONGITUDINAL TANK. GENERAL SPECIFICATIONS • I I I TYP. 3/16 \ d FLOAT GAUGE TYP 3/4 Q HOLES 4 1/2 1 r2 3N6 (4) PLACES TYP. 3/16 ' WATER CAPACITY (GALLONS) 120 1/4 LONG. WELD ALLOWABLE WORKING PRESSURE (PS1G) 250 NOWT EFFICIENCY: ASME 1 W-52 HEAD HEAD TO SHELL 100 % 16 1/4 SEAM HYDROSTATIC TEST PRESSURE (PSIG) 325 SURFACE AREA (SO. FT) 5 SIDE ELEVATION �1 RELIEF VALVE SETTING (PSIG) 3N 250 RFIIFF DISCHARGE RATE .(CFM RECTO.) 1058 END VIEW CODE ASME SECTION VIII DN.1 STANDARDS: UNDERWRITERS LABORATORIES INC. MH -5127 NOTE: TANK MUST BE INSTALLED LEVEL. WITH ALL FOUR LEGS IN SAME PLANE TO ASSURE EVEN DISTRIBUTION OF LOAD AND OPTIMIZE ACCURACY OF GAUGE DEVICE N.F.PA. 68 LP GAS CODE MATERIAL. SPECS.: COUPLINGS SA -105 - -- MOO( .TYPE - - FITTINGS . _ .SERVICE . - -- _ MARK - _.__CITY_.------ --- --__.- DESCRIPTION __- _. _DWG. NO._. REV_ -9Y: - . -_ - -- DESCRIPTION- _ -- -DATE -` TANK FLANGES SA -105 • OTT. _SIZE - -- --- - - - - -- ADAPTOR - -SA105. - - -- - - RE00 - -. - - STIERWOOO _ A 1 3M XH RO. 7553 OT INE433 AM RELIEF VALVE 1 1 SHELL- 0.147 X 54 114•515 114' . SA4140 14 *10 NEW DATAPLATE AND CIEK {OK &1201 B 1 '1 XH RO -,,,,,,,,,L,--="1“-'7,,,„ 'Oi-- BLOAT GAUGE 2 2 HEADS • 24' O.D. X 0.13P- ELLIPTICAL - SA4140 15 CDH REMOVED EVACUATION TUBE 228102 120 W.G. ABOVEGROUND PROPANE TANK -TYPE BS -AP . C 1 1.1N XH FLO. 757aT PVE823B FILL VALVE 3 2 LIFTNO LUGS D•2 18 CDH ANTI G`HFX -1 OK REVISED MONT PRESSURE TO 230 6/13/02 E 1 34 XH RG. 7558R812.0 PVE2033CL.08 MULTI VALVE 4 4 TANK LEOS D - 2 4(ALT.) 2 TANK LEO8 (FREMONT PLANT ONLY ) D - 3 AMERICAN WELDING & TANK HARSCO CORPORATION GAS 8 FLUID CONTROL GROUP 5 1 DOME 0.4 8 1 DATA PLATE 7 1 REGULATOR BRACKET 0.10 0 1 DIP TUBE LENGTH• 7.1' FOR 80 %E40'F oat. 01103/00 puwH RAC a0aFW6D•v CDR 11.... 16 p•.... A -12009