Loading...
RCRT-11-2357Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. r(1,42-1.— 11 Master Permit No. BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING]j ROOFING FINjG OWNER: Name (Fee Simple Titleholder):it/IS ( 1 ' .646 f?4"?' iCalone #: Address: > City: State: Zip: Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: op) LUIS Yr) Nvo City: Miami Shores Folio/Parcel #: County: 019.--0 Miami Dade Zip: Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: Phone #: Address: City: State: Zip: Qualifier Name: Phone #: State Certification or Registration #: Certificate of Competency #: Contact Phone #: Email Address: DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑Addition ❑Alteration ❑New ❑Repair/R:I. lace ❑Demolition Description of Work: ********:** **:* * * * * ** * * * * ***: * * * ** *** * **** Fees************* * ** * * * ***** ** * * * * * ** * * * *** *** ** Submittal Fee $ Permit Fee $Q°U CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ r Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip • Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of , 20 , by day of , 20 , by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: My Commission Expires: My Commission Expires: APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Property Information Map My Home Miami -Dade County, Florida Page 1 of 1 Property Information Map Aerial Photography - 2009 0 This map was created on 12/23/2011 9:06:23 AM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. 30 ft Summary Details: Folio No.: 11- 3206 - 012 -0020 Property: 8851 BISCAYNE BLVD Mailing Address: BISCAYNE 88 TERR LLC 1140 KANE CONCOURSE #5 FL BAY HARBOR ISLAND FL 33154- Property Information: Primary Zone: 6200 ARTERIAL BUSINESS CLUC: 0019 AUTOMOTIVE OR MARINE Beds /Baths: 0/0 Floors: 1 Living Units: 0 Adj Sq Footage: 6,084 Lot Size: 16,258 SQ FT Year Built: 1952 Legal Description: FARMINGTON SUB PB 48 -17 LOT 4 LOT SIZE 16258 SQUARE FEET COC 22120 - 0744 -47 -50 0304 6(6) OR 22120- 0747 0304 03 Assessment Information: Year: 2011 2010 Land Value: $325,160 $325,160 Building Value: $237,778 $237,778 Market Value: $562,938 $562,938 Assessed Value: $562,938 $562,938 Taxable Value Information: Year: 2011 2010 Taxing Authority: Applied Exemption/ Taxable Value: Applied Exemption/ Taxable Value: Regional: $0/$562,938 $0/$562,938 County: $0/$562,938 $0/$562,938 City: $0/$562,938 $0/$562,938 School Board: $0/$562,938 $0/$562,938 Sale Information: Sale Date: 3/2004 Sale Amount: $4,900,000 Sale O /R: 22120 -0747 Sales Qualification Description: Other disqualified View Additional Sales http: / /gisims2.miamidade. gov /myhome /printmap. asp? mapurl = http: / /gisims2.miamidade.g... 12/23/2011 MIAMI SHORES VILLAGE Building Department 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305- 795 -2204• Fax: 305- 756 -8972 12/23/2011 Certified Mail # 7011 0470 0000 8985 5423 Property located at: Address: 8851 BISCAYNE Boulevard Miami Shores, Florida, Permit Number: RCRT -12 -11 -2357 Folio # 11- 3206 - 012 -0020 Notice of Required Inspection /Certification Dear Owner: The Village has been notified by Metro -Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8 -11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two - hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection /Certification. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305- 795 -2204. Norman Bruhn, Building Official 305- 795 -2204 m nJ is) Ir D D D D .7' O rl ri D r- U.S. Postal Services, CERTIFIED MAIL,. RECEIPT (Domestic Mail Only; No Insurance Coverage Provided) For delivery information visit our website at www.usps.com;,, Postage Certified Fee Retum Receipt Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Total Postage & Fees Postmark Here See Reverse for Instructions SENDER: COMPLETE THIS SECTION • Complete items 1, 2, and 3. Also complete item 4 if Restricted Delivery is desired. • Print your name and address on the reverse so that we can retum the card to you. • Attach this card to the back of the maiipiece, or on the front if space permits. 1 ^Article Addressed to: COMPLETE THIS SECTION ON DELIVERY A. SI nature X 0 Agent ❑ Addressee C. D to of�elivery D. Is delivery address different from item 1? 0 Yes If YES, enter delivery address below: 0 No Kitt tiff III two kavr} Cwik� 14aka Isfavid 3315 Article Number ',cosier from service label) m 3811, February 2004 .Type 0 Certified Mail O Registered 0 Insured Mail 0 Express Mail 0 Return Receipt for Merchandise 0 C.O.D. 7011 0470 0000 8985 5423 Domestic Return Receipt 102595-02 -M -1540 • BUILDING RECERTIFICATION INSPECTION REPORT 0441kii, G N PREPARED FOR: BISCAYNE 88 TERR LLC PROPERTY LOCATED AT: P 8851 BISCAYNE BLVD MIAMI, FLORIDA PREPARED BY: engineering group, inc. 10400 NW 33rd Street, Suite 220, Doral, Florida 33172 TELEPHONE: (305) 592 -4538 / FAX: (305) 592 -1433 INfiNITY REAL ESTATE INVESTMENTS KATHERINE LOAIZA PROPERTY MANAGEMENT 1140 KANE CONCOURSE • FIFTH FLOOR BAY HARBOR ISLANDS, FL • 33154 P: (305) 868 - 8203 F: (305) 868 - 8234 kathy @infinitybh.com www.infinitybh.com • • • • • GNP Engineering Group, Inc. rds 1 Di FL 317 F Tel. (305) 592 -4538 March 27, 2012 In accordance with Metropolitan Dade County Ordinance No. 75 -34 (Amended by Ordinance 92 -1), GNP Engineering Group, Inc. has performed a structural inspection of the building located at 8851 Biscayne Blvd., Miami, Florida and determined the building to be structurally safe for continued use under present occupancy. The fmdings of our inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification. The 40 -Yr Recertification inspection is not intended to identify any violations or open permits from the Building Department or other regulatory agencies. Furthermore, the 40 -Yr Recertification inspection is not intended to verify whether there are any open permits, work that has been done without permits or to certify that any work that may have been done complies with any applicable building codes or standards. As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent possible. Angel S. aredes PE #44096 Page S -1 of 8 Angel S. Paredes PE #44096 • • • GNP Engineering Group, Inc. Tel. (305) 592 -4538 114 I 1 ► 33`d St. • ' 221 D s r = 17 F , x I ' 2 -14 STRUCTURAL REPORT 1. DESCRIPTION OF STRUCTURE a. Name of Title: Biscayne 88 Terr LLC b. Street Address: 8851 Biscayne Blvd., Miami, Florida c. Legal Description: FARMINGTON SUB PB 48 -17 LOT 4 LOT SIZE 16258 SQUARE FEET COC 22120 - 0744 -47 -50 0304 6 (6) OR 22120 -0747 0304 03 d. Owner's Name: Biscayne 88 Terr LLC e. Owner's Mailing Address: 1140 Kane Concourse #5 FL, Bay Harbor Island, FL 33154 f. Building Official Folio Number: 11- 3206 - 012 -0020 g. Year Built: 1952 h. Building Code Occupancy Classification: Group B Occupancy i. Present Use: Business j. General Description: One -story building, CBS construction, 6,084 SF. k. Nature of Present Loading: Laundry with washer /dryer machines, open seating areas and office. 1. Additions to Original Structure: Unable to verify since plans were not available. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A Date Q of Actual Inspection: January 18, 2012 �•t ti F L 0 1/4 +� SSIOr4 ‘s• 11 110,0 Page S -2 of 8 Angel S. Paredes PE #44096 • GNP Engineering Group, Inc. Tel. (305) 592 -4538 1 1 400 33rd i 220. 1 i r: 8 1 2 F 0 '- 4 c. Name and Qualification of Individual Submitting Inspection Report: Angel S. Paredes, P.E. (License #44096) d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: The building was accessible at time of inspection. 3. REPAIRS: a. Structural Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify structural deficiencies and to recommend that repairs be made to the structure, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the structural deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. I 11111 • ,. 'p \RED6S �i Y � . • S �• Yi� NIP g Page S -3 of 8 Angel S. Paredes PE #44096 • GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 NW 33`d St., Suite 220, Doral, FL 33172 Fax-0-05:027=11-131 4. SUPPORTING DATA a. N/A Sheets of Written Data b. N/A Photographs c. N/A Drawing (Plan) 5. PRESENT CONDITION OF STRUCTURE a. General Alignment: Good condition. [N /A] Bulging - None observed during inspection. [N /A] Settlement - None observed during inspection. [N /A] Deflection - None observed during inspection. [N /A] Expansion - No expansion above normal observed during inspection. [N /A] Contraction - No contraction above normal observed during inspection. b. Portions Showing Distress: None observed. c. Surface Conditions: Fair condition. d. Cracks: Hairline and fine sized stucco cracks. e. General Extent of Deterioration: None visible. f. Previous Patching or Repairs: Roofing repairs. 6. MASONRY BEARING WALLS a. Concrete Masonry Units: Good condition. r€9ncrete Tie Columns: Good condition. E, 1r : s ..7 • ti PL SS i00" Page S -4 of 8 Angel S. Paredes PE #44096 • GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 NW 33rd St., Suite 220, Doral,_FL 33172 Fax (305) 592 -1433 c. Reinforced Concrete Tie Beams: Good condition. d. Lintels: Good condition. e. Other Type Bond Beams: Good condition. f. Masonry Finishes (Exterior): 1) Stucco — Fair condition. 2) Veneer—N/A 3) Paint — Good condition. 4) Other - N/A h. Masonry Finishes (Interior): 1) Vapor Barrier - N/A 2) Furring & Plaster — Good condition. 3) Paneling — N/A 4) Paint — Good condition. 5) Other - N/A i. Cracks: 1) Location - No cracks observed in concrete masonry walls. 2) Description - N/A j. Spalling: 1) Location - No spalling observed in concrete masonry walls. viroutsti INRE E•r a* • CC 4rr y, rr • ; 2V v **°+#6 J ••, FL 09ko s �1 Page S -5 of 8 Angel S. Paredes PE #44096 • GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 NW 33`d St.. Suite 220, Doral, FL 33172 Fax (30.5,) 592 -1433 2) Description - N/A k. Rebar Corrosion: [ X ] None Visible [N /A] Minor (patching will suffice) [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) / Description 7. FLOOR & ROOF SYSTEMS a. Roof System: 1) Description — Flat roof with modified roofing surface. The roof framing consists of wood joists. 2) Heavy Equipment and Condition of Supports — HVAC equipment supports observed to be secure and in good condition. 3) Types of Drains /Scuppers and Condition — N/A 4) General Condition - The roof surfaces were observed to be in fair condition. b. Floor System: The floor system consists of concrete slab on grade. Floor coverings, furniture and stored materials prohibited a visual inspection of the entire floor surface. However, visible floor surface was observed to be in good condition. c. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random; however, most of roof framing is concealed. Limited visibility from boiler room. 8. STEEL FRAMING SYSTEMS a. Description: Steel columns and I- beams. y1 t111 11pr,, SE .1% Page S -6 of 8 Angel S. Paredes PE #44096 • • • GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 3'� NW 3 St , Suite 220, Doral, FL 33172 Fax (305) 592 -1433 b. Exposed Steel: Not visible. Steel framing is concealed by finishes. c. Concrete or Other Fireproofing: N/A d. Elevator Sheave Beams & Connections, and Machine Floor Beams: N/A e. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random; however, mostly concealed by finishes. 9. CONCRETE FRAMING SYSTEMS a. Description: CBS construction with reinforced concrete columns and concrete beams. b. Cracking/Spalling: [ X ] Not Significant [N /A] Location and Description of Members Affected and Type c. General Condition: Good condition. d. Rebar Corrosion: [ X ] None Visible [N /A] Location and Description of Members Affected [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) e. Samples Chipped Out in Small Areas: [X ] No [N /A] Yes / Description f. ,Qd''. _�' pees Opened for Inspection: N/A 1. ii%,,S1 4n rro�. -. 14704 • Ih ! A� - .. • ow WO Page S -7 of 8 Angel S. Paredes PE #44096 • GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 NW 33rd St., Suite 220, Dorah FL 33172 Fax (305' 592 -1433 10. WINDOWS a. Type: Aluminum frame, fixed type windows. b. Anchorage: Screws observed to be secure and in good condition. c. Sealants: Fair condition. d. Interior Seals: Good condition. e. General Condition: Good condition. 11. WOOD FRAMING a. Type: Wood joists for roof framing systems. b. Metal Fittings: Not visible. c. Joints: Not visible. d. Drainage: No accumulation of moisture observed on ceiling finishes. e. Ventilation: Not visible. f. Concealed Spaces Opened for Inspection: Ceiling tiles removed at random; however, most of roof framing is concealed. Limited visibility from boiler room. Page S -8 of 8 Angel S. Paredes PE #44096 • • • GNP Engineering Group, Inc. I' I I \\A rd _I 1 I_ -_ W Tel. (305) 592 -4538 Fax (30505) 592 -41433 March 27, 2012 In accordance with Metropolitan Dade County Ordinance No. 75 -34 (Amended by Ordinance 92- 1), GNP Engineering Group, Inc. has performed an electrical inspection of the building located at 8851 Biscayne Blvd., Miami, Florida and determined the building to be electrically safe for continued use under present occupancy. The findings of our inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification. The 40 -Yr Recertification inspection is not intended to identify any violations or open permits from the Building Department or other regulatory agencies. Furthermore, the 40 -Yr Recertification inspection is not intended to verify whether there are any open permits, work that has been done without permits or to certify that any work that may have been done complies with any applicable building codes or standards. As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present condition of the building based up • : e valuation of observed conditions, to the extent possible. Benny . onzalez PE #50746 t it e,,, G N� fts • • • *' No. 50748' STATE OF QA ONAU • r , Page E -1 of 8 Benny P. Gonzalez PE #50746 • GNP Engineering Group, Inc. 1A 11 ■►A rd • - -I 1s Tel. (305) 592 -4538 Fax (0°) 592 -41433 ELECTRICAL REPORT 1. DESCRIPTION OF STRUCTURE a. Name of Title: Biscayne 88 Terr LLC b. Street Address: 8851 Biscayne Blvd., Miami, Florida c. Legal Description: FARMINGTON SUB PB 48 -17 LOT 4 LOT SIZE 16258 SQUARE FEET COC 22120- 0744 -47 -50 0304 6 (6) OR 22120 -0747 0304 03 d. Owner's Name: Biscayne 88 Terr LLC e. Owner's Mailing Address: 1140 Kane Concourse #5 FL, Bay Harbor Island, FL 33154 f. Building Official Folio Number: 11- 3206 - 012 -0020 g. Year Built: 1952 h. Building Code Occupancy Classification: Group B Occupancy i. Present Use: Business j. General Description: One -story building, CBS construction, 6,084 SF. k. Nature of Present Loading: Laundry with washer /dryer machines, open seating areas and office. 1. Additions to Original Structure: Unable to verify since plans were not available. 2. INSPECTIONS: a. Date of Notice of Required Inspection: N/A No. 907 STATE Lani Page E -2 of 8 Benny P. Gonzalez PE #50746 GNP Engineering Group, Inc. Tel. (305) 592 -4538 1-0-400-11,131/2 Fax 305) 592 -41433 411/ b. Date of Actual Inspection: January 18, 2012 • c. Name and Qualification of Individual Submitting Inspection Report: Benny P. Gonzalez, P.E. (License #50746) d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: Building was accessible at time of inspection. 3. REPAIRS: a. Electrical Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify electrical deficiencies in the buildings and to recommend that repairs be made to the electrical system, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the electrical deficiencies as icdeFntified in this report. In addition, the Owner will be responsible for the necessary permits for construction and for having a licensed Page E -3 of 8 Benny P. Gonzalez PE #50746 GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 NW 33'b St _Suite 220_ nnral_ Fi. 33172 Fax (305L59.2- 41433. • Contractor perform the work in accordance with the requirements of the Florida Building Code. • 4. SUPPORTING DATA a. N/A Sheets of Written Data b. N/A Photographs c. N/A Drawing 5. ELECTRIC SERVICE a. Estimated Size, Amperage: 400 amps [ ] Fuses [ X ] Breakers b. Phase: [ X ] Three Phase [ ] Single Phase c. Condition: [ X ] Good [ ] Fair [ ] Needs Repair d. Comments: No comments. 6. METER AND ELECTRIC ROOMS a. Clearances: [ X ] Good [ ] Fair [ ] Requires Correction b. Comments: No comments. 7. GUTTERS a. Location: [ X ] Good [ ] Requires Repair b. Condition: [ X ] Good [ ] Requires Repair c. Comments: No comments. GOi ", . *AGE d+lS • • No,. 55074 "o • -• ~ STATE Page E -4 of 8 Benny P. Gonzalez PE #50746 • GNP Engineering Group, Inc. 1' I I t►, rd _1 1 Tel. (305) 592 -4538 Fax (3.�) 592 -41433 8. ELECTRICAL PANELS a. Location: Laundry area. b. Condition: [ X ] Good [ ] Requires Repair c. Comments: Circuit breaker panels. 9. BRANCH CIRCUITS a. Identified: [ X ] Yes [ ] No, must be identified. b. Conductors: [ X ] Good [ ] Deteriorated [ ] Must Be Replaced c. Comments: No comments. 10. GROUNDING OF SERVICE a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 11. GROUNDING OF EQUIPMENT a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 12. SERVICE CONDUITS/RACEWAYS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 11r11I .49 GO • No STATE OF ©R . Page E -5 of 8 Benny P. Gonzalez PE #50746 • GNP Engineering Group, Inc. Tel. (305) 592 -4538 rd - 1 11 hI 13. SERVICE CONDUCTORS & CABLES a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 14. WIRING METHODS, CABLES & CONDITION a. Types: [ X ] Conduit Raceways: [ X ] Good [N /A] Conduit PVC: [ ] Good [N /A] NM Cable: [ ] Good [N /A] BX Cable: [ ] Good b. Comments: No comments. [ ] Requires Repair [ ] Requires Repair [ ] Requires Repair [ ] Requires Repair 15. FEEDER CONDUCTORS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 16. EMERGENCY LIGHTING a. Condition: [ X] Good [ ] Requires Repair [ ] None b. Comments: Emergency lights should be inspected periodically as part of routine building maintenance. 17. BUILDING EGRESS ILLUMINATION 0 111(11•, an: X ] Good • • 4 •: R 1O, P 4 +149141 [ ] Requires Repair [ ] None 7 12i Page E -6 of 8 Benny P. Gonzalez PE #50746 • • • GNP Engineering Group, Inc. I,II ■►A rd 1 Tel. (305) 592 -4538 Fax (305)592 -41433 b. Comments: No comments. 18. FIRE ALARM SYSTEM (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Fire alarm system is not required as per Section 39.3.4.1 of the NFPA 101 Life Safety Code. 19. SMOKE DETECTORS (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: Refer to comments in Section 18. 20. EXIT LIGHTS a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: Exit lights should be inspected periodically as part of routine building maintenance.. 21. EMERGENCY GENERATOR (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 22. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS a. Condition: [ X] Good [ ] Requires Repair [ ] None b. Comments: No comments. owtre o' s , '`+ EN No.507 ro * a STATE AlVA'b °;tip` Page E -7 of 8 �111911� Benny P. Gonzalez PE #50746 GNP Engineering Group, Inc. Tel. (305) 592 -4538 10400 NW 33rd St., Suite 220, Doral, FL 33172 Fax (305) 592 -41433 41110 23. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING a. Condition: [ X ] Good [ ] Requires Additional [ ] None b. Comments: No comments. • • 24. SWIMMING POOL WIRING (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 25. WIRING TO MECHANICAL EQUIPMENT a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: No comments. Benny P. Gonzalez PE #50746 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI -DADE COUNTY, Date: March 27, 2012 Re: Case No: Property Address: Building Description: N/A 8851 Biscayne Blvd., Miami, Florida One story, CBS construction, 6,084 SF The undersigned states the following: 1. I am a Florida Registered Professional Engineer or Architect with an active license. 2. On March 26, 2012, I measured the level of illumination in the parking lot(s) serving the above referenced building. 3. The level of illumination provided in the parking lot(s) meets the minimum standards for the occupancy classification of the building as established in Section 8C -3 of the Code of Miami -Dade County. • (Signature and S 5`aI Angel Parl (Print N' •