RF-11-1630Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 164126 Permit Number: RF -9 -11 -1630
Scheduled Inspection Date: March 29, 2012
Inspector: Rodriguez, Jorge
Owner: BROWN, BRUCE
Job Address: 402 NE 95 Street
Miami Shores, FL 33138-
Project <NONE>
Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Flat
Phone Number (305)758 -1303
Parcel Number 1132060140470
Phone: 305 - 757 -2612
Building Department Comments
RE -ROOF FLAT ROOF WITH GAF 3 PLY SBS MODIFIED
BITUMEN OVER 1.5 ISOCYANURATE INSULATION
Inspector Comments
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
March 28, 2012
For Inspections please call: (305)762 -4949
Page 5 of 22
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST
PERMIT NO.
STATE OF FLORIDA:
COUNTY OF MiAMI -DADE:
BE POSTE) ON THE JOB SITE AT TIME OF FIRST INSPECTION
oI 4f oc-7c
TAX FOLIO NO.
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real
property, and in accordance with Chapter 713, Florida Statutes, the following information
is provided in this Notice of Commencement.
1. Legal description of property and
2. Description of improvement
reet/address: Oal A.) E 9S-
00f C�
3. Owner(s) name and address: .A>�
Interest in property:
Name and address of fee supple titleholder.
4. Contractor's name, address : d • • e
liv
11111111111111111111111111111111111111111 1111
CFN 2011R0831103
DR P•k 27924 Ps 0080; tips)
RECORDED 12/12/2011 14:07:08
HARVEY RUM! CLERK OF COURT
MIAr1I -DADE COUNTYr FLORIDA
LAST PAGE
pace above reservea or use or recvrumy ..ua.e
SHo r 3 3S'
FGA'
t!�L��ii�ih'
5. Surety: (Payment bond required by owner from contractor, if any,
Name, address and phone number.
Amount of bond $
6. Lender's name and address:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)7., Florida Statutes,
Name, address and phone number.
8. in addition to himself. Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section
71303(1)(b), Florida Statutes.
Name, address and phone number:
9. Expiration date of this Notice of Commencement
(the expiration date Is 1 year from the date of recording unless a different date Is spadfted)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENTARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR. PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Signatures) of Owner(s) or Owner(s)' Authorized Officer /Director/Partner /Manager
Prepared By Prepared By
Print Name cld,C' �� �. Print Nam (*JD
Title/Office ,�; „� Title/Office
STATE OF
COUNTY 0
The forgoing instrumentryva know(Qdged before me this
By
day of
ndividually, or as for
❑ Personally known, or 0 produced the following type of Identifi on•
Signature of Notary Public:
Print Name:
(SEAL)
VERIFICATION PURSUANT TO SECTION 52.525`FLORiDA STATUTES
Under penalties of perjury, I declare that I have read the foregoing and
that the facts stated in it are true, to the best of my knowledge and belief.
Signatures Owner(s) or
c.-rATE OFFLOROM
Odra D. Hart
Vision s'DD867359
Expirts: APB. 02,1013
mar atom: ma: gorr vi cc, rxe
Authorized Officer/Director/Partner/Manager who signed above:
By
STATE OF KOWA, COUNV CO,' i=
HEMP/ FYMei thfa . Q'14:clfy
origfnal Nod in this Owe at dev gf
'EC 12 zap AD2Q.._._
6�411NESS my h and Otciai Seal.
HARVEY R1 , CLERK ofCftoutt and County Courts
l.4A
a h�
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949 � Permit No. 1 j l Master Permit No.
BUILDING
PERMIT APPLICATION
FBC 20
IEMERCE
',Er 0 1, 201
Permit Type: BUILDING ROOFING
OWNER: Name (Fe Simple Titleholder): 1.6-4' etv /fo&J i✓ P hone#: 3c 7 /f-- lv
Address: L »E / f
City: esk/ / 5 70 /l e s State: A—L Zip: 34/11
Tenant/Lessee Name: Phone #:
Email:
JOB ADDRESS:
X01 A4 PS-5c
City: Miami Shores County:
Folio/Parcel #: / 1 3D-06 01 (1 0
Is the Building Historically Designated: Yes
0
Miami Dade
NO r/
Zip: 35/32"
Flood Zone:
CONTRACTOR: Company Name: /3 �r�0[', �� /� Phone #: 55 7S7 /Z
Address: /.5—q 97 sr
City: He 4-m / SPA) /t 'S State: Zip: 3 3 /3
Qualifier Name: j <s SIri007---- Phone #: 3e 757'4,24 %z
State Certification or Registration #: c( C 0/ 3 0C Certificate of Competency #: n52%109654
i
Contact Phone #: Email Addres ;L' ,404 oa eco/ C 6/0
DESIGNER: Architect/En: neer: - Phone #: V
Value of Work for this Permit: $ /0 9 3 7 Square/Linear Footage of Work: g 7'
Type of Work: ❑Addition ❑Alteration // ❑ ' New epair/Replace ❑Demolition
Description of Wo k: ?r 40 r 91 ho i n 64-f 3/4 5/53
O fc Pc, / S- c C '',4
** *** * ****** ******** ****** ******* IC** ***F **** x**** *• x+ xx: ******+ x ****** *******a: ***x:*****
Submittal Fee $ Permit Fee $ 6 CCF $ CO /CC $
Scanning Fee $ Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $ °`31 • 10
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOIT.RRS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In t absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
f re
a caner or gent
The foregoing instrument was acknowledged before me this
day of 20LL , by 6(iu tbrntrA)I
who isers known to me or who has produced
As identification and who did take an oath.
2
NOTARY PUBLIC:
Sign: c
Print:
My Commission Ex
mart litaviAC-STAi:k. Or k
Odra D. Hart
Oxamisaiou #D
ExPl= �, " '' 02, EU
inn Ma= DOATMO Mt- Mt
Signatu
Contractor ryry
The ore oing instrument was acknowledged before me this_°
, 20 fl , by Jainps 0.6bc
day of
a
who is pers nally known to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
My Commission Ex
Scadrz D. Hart
Commission ODD867SP
02, to
. °ter r
****** **************m**** ******** **** ******** **** ********+x+a********** ********** *********a:******** **** *****
APPROVED BY
Plans Examiner
Structural Review
(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09)
Zoning
Clerk
Wawa .5.4 'Veit We Veitanemegge
10050 NE 2nd Ave * Miami Shores, Fl 33138
Phone 305-795-2204; Fax 305.756 -8972 •
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, Fl 33138
Re: Owner's Name: A2vet~ 4 ,u) ,)
Property Address: S®02- ,d, 95- 5r,
Roofing Permit Number:
Date: t- Z --
Dear Building Official:
I 6i2ae-c fro a4) certify that I am not required to retrofit the roof to wall
connections of my building because:
just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please
attach proof of ad valorem taxation.
0 The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or
with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC)
State of Florida
County of Dade
42,ve e
Print Name
roue
The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above
property mentioned.
Sworn to and subscribed before me this �► Y
day of � � � 1_
iD. lit
Notary Public, Sate of Florida at Large
''Wan the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300.000.00, and the building was not constructed with
.:Bi; nor a 199.1 SFBC. Then you rnust.provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Florida Building Code Edition 2007
High Velocity Hurricane Zone Uniform Permit Application Form
Section A (General Information)
Master Permit No. Process No.
Contractor's Name 0 4 £ti%O o GLnJ9
Job Address o - N E /-r 5r - Ee r
Low Slope
I I Asphaltic Shingles
ROOF CATEGORY
Mechanically Fastened Tile
C Metal Panel /Shingles
C' Prescriptive BUR -RAS 150
ROOF TYPE
C� Morta
[1 Woo
Li New Roof tRe- Roofing U Recovering Ll Repair Li Maintenance
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF)
,B7
687
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scupper
overflow drains. Include d ' ensions of sections and levels, clearly identify d
pressure zones and Io «:tion o •arapets. 5p-Al(S#1 5 -(7,1E
rtlo sc
e slons
pper§ !and
• f elevated
;,.;.n ,; = :;
1+ II::v :�� II : ii_.'R U pill; - i ' i- -G TI ii iiiiii ■ i�::ommomme:�:
■,�■11� ■ ■ ■ ■f/.�� ■���■ ■ �■■ ����■ ��■ ����■ ���������� ,���N�ir■i�..�iiiiiiiiii�f■i■
r. low ■ ■■ ■'.. w■ If�■■ _ _
Cu ■l■■ fly ■:IH •"i'=•�� =�C�' �1' .�■'�'�::��'1'�.S'111111111111.4111111 111
r�i �_rll i�l, �■ ■i Emma ■am■■■■.■■■■uii■■■■■■■
11 :� : um �'�i = =SIQ■■ C :I
ii. al 1 ,! i"i, ��. •I� .t 11111 :.111111 it
ei■�i ' ij =: UU r ■■ p1�' I' y,�: 1: rIlmmu:■i■i ■ ■■ •
.i:: i" 1 ■ : NI p ■ ■ _/��I1� ■ ■/■ arL�y�r ►/. f ■ ■ ■ ■CO: ::: :111 11
■.. .0 ■.� 11 :=1U1 Rpm. ■ ■■■■■1■■.■':■■■■■■■■■■
.... �:::'■:: :�i:� :O::::::::: :::1'::1i
11 ■! ■N .. ■ ....!! .... �� ■. ■.■ ■.�■.■■.� ■Y.■.■■■■■■■.■■■:■■
■■■u■■i: ■ .. ■i .■
■C ■ ■ ■ .u■ ■ ■,r-S a ..i■ _ _ ■_■■ ■r ■11111::::.:x11111.1111
■■■• ■ =■- . ■ ■■■■■■ ■■
■■ ■ U:■ : ■1 C• 1 -; �� , 1■■..■ ■■■■ ■■ ■■ UU ■11./1■ ■■ ■ ■ ■■ ■■ ■ ■ ■ ■ ■1 ■ ■.� ■■
1UA111::■■■■■■■■■■L..■■..■■ .1 ■i 1 .1111§001111111110411111111111191
::11:■ 01 • ■:■11:.%11::::::::::1:■
41.. ■.B■�■. ■■�� ■. ■■■■1 �— ■■ ■■■ 1■ :: : 11 =: ::.•::: 11 :■■■■■■■■1■:'.�i�.=1■1 ■:�■:: =is:: 'mi:■a■ ■.::::un::°•:::::::::1� oll
ul':■■■.■■■■■■■■■1. ■ ■■de I■■: 1:11 ■:::::$:::::::::a°■ ralap'::C l
:1 ■: :.. ■■ ■ ■ ■ ■■.■ ■ ■ ■.. ■ : 1 CI 1 11: Ii1Q�1 :1111���1
1■ 1 111........111. • ■ ■11� �: ■i iiii3 C��i:::
1 1��:::: �� ill
u)
- Z
0
w -
0 <
w —'
3
J u_
< Cr
Y a
I- 2
U LI-
Z
}
a �
0
• z_
• C
O c:
n
U <
3
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High - Velocity Hurricane Zone Uniform Permit Application,
Section C (Low Slope Application)
P11 in specffic roof assembly components
and Identify manufacturer
(If a component is not used, identify as "NA ")
System Manufacturer
Product Approval No.:
Design Wind Pressures, From RAS 128 or Calculations:
Pmax1: I Z Pmax2: 7- 3 Pmax3: 13/. `-/
Max. Design Pressure, from the specific Product
Approval system:, 5-2 • .I
Deck:
Type:
Gauge/Thickness:
r'
yy
Slope: r
AnchorlBase Sheet & No. of Ply(s): tf i-1 I yew. A- 630
Anc orlBase Sheet Fas enerBondi M terial:
Sly" � yS r ® ,� /.2
Insulation Base Layer �C(q/}i�.!/Z offr
Base Insulation Size and Thickness: /5 `V x `f
Base Insulation Fasten !Bondi Mate I:
/d.c r-
Top Insulation Layer.
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
ie4-oit4rfd 5;71-41-,74 a&-A17-
Base Sheet(s) & No. of Piy(s):
Base S®eF ne g Material:
Ply Sheet(s) & No. of Ply(s): i,' ,e '
Ply Sheet FanerlBondi g � rjal: e
Top Ply: �v / - /r%d ' f7a Fi
Top Pty Fas r7 MatEria(,q
FLORIDA BUILDING CODE — BUILDING
orm.
Surfacing: /A-
Fastener Spacing for Anchor/Base heat Attachment:
Field: lP " oc @ Lap, # Rows @ 6" oc
Perimeter L " oc @ Lap, # Rows 1®ig 4" oc
Corner. ' " oc @ Lap, # Rows (0-
0! @ G " oc
Number of Fastener? Per insulation Board:
Field Perimeter Corner
Illustrate Components Noted and Details as
Applicable:
Woodblocking, Gutter, Edge Termination, Stripping, Flashing,
Continuous Cleat, Cant Strip, Base Flashing, Counter -
Flashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material Thickness, Fastener
Type, Fastener Spacing or Submit
Owner's Notification Form 07
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of this section. The provisions of
Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the
industry for roofing system installations. Additionally, the following items should be addressed as part of the
agreement between the owner and the contractor. The owner's initial in the designated space indicates that the
item has been explained.
/� w 1. Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane
Zone are for the purpose of providing that the roofing system meets the wind resistance and water intrusion
performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions.
Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed
as part of the agreement between the owner and the contractor.
lk j�® . Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida
Building Code. (The roof deck is usually concealed prior to removing the existing roof system).
rA:Aiii 3. Common roofs: Common roofs are those which have no visible delineation between neighboring
units i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofmg contractor and/or
owner should notify the occupants of adjacent units of roofing work to be performed.
-ail 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be
rail. P g P P g
viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetrations of the underside of the decking may not be acceptable. The owner provides the option of
maintaining this appearance.
_r
, , . Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural
distress and may require the review of a professional structural engineer. Ponding may shorten the life
expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
roofing system is removed. Ponding conditions should be corrected.
6. Overflow scuppers. (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance
with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing.
entilation: Most roof structures should have some ability to vent natural airflow through the
i erior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. Exception: Attic spaces, designed by a Florida - licensed engineer or registered architect to eliminate
the attic venting, venting shall not be required.
Owner's /Agent's Signature:
Contractor's Signature:
r
Property Address: ¥ „/' •_97 7
.1111111ir' 'AlariffffralPP.
Date: /
Permit Number:
/
MIA M IGZE
BUILDING $BODE COMPLIANCE OFFICE (BCCO)
PRODUCT CpNTROL DIVISION
NOTICE F ACCEPTANCE (NOA)
MIAMI -DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375 -2908
GAF Mateca1 Corporation
1361 Alps toad
Wayne, NJ 07470
SCOPE:
This NOA ii being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building
Code and Product Review Committee to be used in Miami Dade County and other areas where allowed
by the Authority Having Jurisdiction (AHJ).
This NOA ehall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Di'Fsion (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the fight to have this product or material tested for quality assurance purposes. If this product or
material fair to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AH0 may immediately revoke, modify, or suspend the use of such product or material within
their jurisdiq'tion. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Prou'uct Control Division that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and tho High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted
herein.
RENEWAI`?, of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if has been a revision or
change in th9s materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement; of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Fi ilure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTIODN: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 07- 1203.01 and consists of pages 1 through 31.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 09- 0224.01
Expiration Date: 11 /06/13
Approval Date: 04/08/09
Page 1 of 31
APPROVEh INSULATIONS:
Product Name
EnergyGuar`rM Fiberboard
EnergyGuard'M Permalite
EnergyGuard,* Strip
EnergyGuard Recover Board
EnergyGuardR " Tapered Edge Strip
EnergyGuard 'M Polylso
EnergyGuardFM RA, RN
EnergyGuard!rM Composite, RA
DensDeck® ''
DensDeck Prime®
DensDeck DtaraGuardTM
Structodek®
Structodek® TD
SecurockTM
APPROVED FASTENERS:
Fastener
Number
1.
Product
Name
D411 -TecTM #12 Standard,
#14 and #15 extra Heavy
Duty Fastener, Heavy Duty
R Iofing Fastener
2. Dr 11 -TecTM ASAP
3. Dr11 -TecTM CR Base
Sheet Fastener and Plate
4. Drill-Teem Galvalume
Plates
5. Drill -TecTM Polypropylene
Plates
6. Drill -TecTM AccuTrac
Plate
Table 2
Product Description
Fiberboard insulation
Perlite insulation board
Cut perlite board
Perlite recover board
Tapered perlite board
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate /wood fiberboard or
perlite composite
Water resistant gypsum board
Water resistant gypsum board
Water resistant gypsum board
Wood fiber insulation board
Flame Resistant High Density Wood
Fiber board.
Fiber reinforced roof board
TABLE 3
Product
Description
Dimensions
Insulation fastener and Various
Base Play fastener for
steel, wood & concrete
decks.
Pre - assembled Drill -TecTM Various
Fasteners and metal and
plastic plates.
Base sheet fastening Various
assembly.
Round Galvalume stress
plates.
Round polypropylene
stress plates.
Square Galvalume® coated 3" Square
steel plate.
Manufacturer
(With Current NOA)
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
G -P Gypsum Corp.
G -P Gypsum Corp.
G -P Gypsum Corp
Knight Celotex
Knight - Celotex
USG Corporation
Manufacturer
(With Current NOA)
GAF Materials Corp.
GAF Materials Corp.
GAF Materials Corp.
3" and 3 W GAF Materials Corp.
3" and 3 %i" GAF Materials Corp.
OMG
NOA No.: 09- 0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page7of 31
APPROVED ASSEMBLIES
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Desc'iption: 19/32" or greater plywood or wood plank
System Type A(1): Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
One or morn layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density /ftz
EnergyGuardTM Polylso, RA, RN, EnergyGuardTM Composite RA,
Minimum 17 thick N/A N/A
Wood Fibe, Structodek ®, Structodek® TD, EnergyGuardTM Recover Board
Minimum %" thick N/A N/A
EnergyGuardTM Perlite
Minimum 3h" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the PVT range and at a rate of 20-40 lbs /100 ft2. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanrzrate side facing down. GAF requires either a ply of GAFGLAS® STRATAVENT®
Eliminator"! Perforated laid dry or a layer of EnergyGuardTM, Perlite or wood fiber overlay
board on all polyisocyanurate applications.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
Anchor sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® EliminatorTM Nailable
Base Sheet, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID®
SBS Heat- We1dTM Smooth or RUBEROID® SBS Heat- We1dTM 25 base sheet
mechanically fastened to deck as described below;
Fastening GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any
Options: of above Anchor sheets attached to deck with approved annular ring shank nails
and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows
12" o.c. in the field.
(Maximum Design Pressure —45 psf, See General Limitation #7)
GAFGLAS® Ply 4, GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any
of above Anchor sheets attached to deck with Drill -Teem #12 standard, #14 or #
15 Screws and 3" Drill -TecTM steel plate or Drill-Teem AccuTrac Plates, 12" o.c.
in 3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf, See General Limitation #7)
NOA No.: 09- 0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 9 of 31
Base Sheet:
GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
GAFGLAS® #80 ULTIMATM, RUBEROID ®20, RUBEROID® Mop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with
Drill -TecTM #12 standard, #I4 or # 15 Screws and 3" Drill -TecTM steel plate or
Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap.
The other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #V
Any of above Anchor sheets attached to deck approved annular ring shank nails
and 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the
4" lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with
Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or
Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The
other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
(Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM Base
Sheet, GAFGLAS® PLY 4, GAFGLAS Flex PIyTM 6, GAFGLAS®
STRATAVENT® EliminatorTM Perforated (laid dry), RUBEROID® Modified Base
Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat -
WeIdTM Smooth or RUBEROID® SBS Heat- We1dTM 25 directly over the top layer
of insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 Ibsisq (see General Limitation #4).
(Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6
sheet, GAFGLAS® #80, RUBEROID® MOP Smooth, RUBEROIDel 20 adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbs. /sq.
One or more plies of RUBEROID® 20, RUBEROID® 30, RUBEROID®
EnergyCap SBS 30 FR, RUBEROID® 30 FR RUBEROID® MOP Smooth,
RUBEROID® Mop 170 FR, RUBEROID® Mop Granule, Roof MatchTM SBS Mop
Granule, RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROID®
ULTRACLAD® SBS, or RUBEROID® Dual FR fully adhered in an approved
asphalt at an application rate of 25 lb. /sq. ± 15 %.
NOA No.: 09- 0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 10 of 31
Surfacing:I (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood
coat of approved asphalt at 60 Ibs./sq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20- 40lbs. /sq.
3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5 gal. /sq.
4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT®
MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to
1.5 gal. /sq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCote® roof coating applied at 1 to 1.5 gal. /sq.
6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 gal. /sq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum
Design Prsure:
See Fastening Above
NOA No.: 09- 0224.01
Expiration Date: 11/06/13
Approval Date: 04 /08/09
Page 11 of 31
WOOD DECK SYSTEM LIMITATIONS:
I A slip sheet is required with Ply 4 and Flex Ply TM 6 when used as a mechanically fastened base or anchor
sheet.
2. Minimum ''A" Dens Deck or '' /z" Type X gypsum board is acceptable to be installed directly over the wood
deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening
pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied
using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in
three rows, one at each side lap and one down the center of the sheet allowing a continuous area of
ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon
to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275
Ibf., as tested in compliance with Testing Application Standard TAS 105. if the fastener value, as field -
tested, are below 275 Ibf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor /base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official, a
revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is
specifically referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). When this limitation
is specifically referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9B -72 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
APPROVED
NOA No.: 09- 0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 31 of 31
TGFI?.R1306 - Roofing Systems
ONLINE CERTIFICATIONS DIRECJORY
Page Bottom
See General Information for Roofing Systems
GAF MATERIALS CORP
1361 ALPS RD
WAYNE, NJ 07470 USA
Page 1 of 48
TGFU.R1306
Roofing Systems
Roofing Systems
R1306
"Ruberord 20" or "Ruberoid Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications.
1/2-in. thick (minimum) gypsum board or V4 -in. thick (min) G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime® Roofboard" or
"DensDeck DuraGuard '" Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing
system is acceptable for use over combustible (15/32 -in. minimum) roof decks. However, the butt joints in the gypsum board and G-P Gypsum
Corp. "DensDeck ® Roofboard," "DensDeck Prime® Roofboard" or "Dens Deck DuraGuard '" Roofboard" are to offset a minimum of 6 -in. with the
butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board.
Multiple plies of "GAFGLAS® Ply 4" or "Tri -Ply Ply 4 ", or "Ply 6" may be adhered to G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck
Prime® Roofboard" or "DensDeck DuraGuard '" Roofboard" in hot roofing asphalt.
"EnergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification.
"GAF Stratavent® Eliminator'" Venting Base Sheet ( Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a
recover over existing roof systems.
"GAFGLAS® Perlite Insulation" may be utilized as a cover boaro over "EverGuard" insulation in any of the following systems.
Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane insulation adhesive.
Polystyrene referenced in any of the following Classfications include "EnergyGuard EPS Insulation ".
References to glass fiber insulation nclude "EnergyGuard Fiberglass Insulation ".
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
Type G2 asphalt glass mat base sheet ( "GAFGLAS® 575 Base Sheet" or "Tri -Ply 575 Base Sheet ", or "GAFGLAS® 580 ULTIMA ") is a suitable
alternate for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS® Ply 4" or "Tri -Ply Ply 4 ", or "GAFGLAS® Ply 6 ") in the Class A, B or C roof systems
indicated below.
The roof deck may first be covered with one ply type G2 asphalt saturated glass mat base sheet "GAF Stratavent® Eliminator'" Venting Base
Sheet (Perforated)" or "GAF Stratavent® Eliminator'" Venting Base Sheet (Nailable)." Perforated to be loose laid or mopped and nailable to be
mechanically attached granule side down.
As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS® 575 Base Sheet" or "Tri -Ply 575 Base Sheet" or "GAFGLAS® 580 ULTIMA" or
"GAF Stratavent® Eliminator'" Venting Base Sheet ( Nailable)" may be substituted for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS® Ply 4" or
"Tn -Ply Ply 4" or "GAFGLAS® Ply 6 ") as the nailed base ply in the following systems.
Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened.
Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened.
"GAFGLAS® Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C systems listed below.
When "pert te" is referenced, this includes "GAFTEMP PERMALITE®" or any other UL Classified perlite insulation.
Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed.
Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C-15/32
or NC.
_ 1_:._ /V NIA 74,.. „,- .1 „trOl IQ12Y1.7I rR AMP. /shownaae.html ?name =T... 5/21/2010
TGFU.R1306 - Roofing Systems Page 8 of 48
4. Deck: NC Incline: 2
Insulation (Optional): — Perlite, glass fiber or wood fiber, any thickness.
Membrane: — "Ruberoid Torch Granule 1" (modified bitumen).
Surfacing: — 3/4 to I1/2-in. diameter river bottom stone at 1000 Ib /100 -ft2 or concrete pavers weighing not less than 10 -Ib /1 -ft2 and
spaced not more than 1/8 in.
Class A - Fully Adhered
1. Deck: NC Incline: 1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite /polyisocyanurate composite or perlite /urethane composite or wood fiber /polyisocyanurate composite or phenolic, any thickness.
Base Sheet (Optional): — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop" (Smooth or
Granule) or "Ruberoid Mop Plus Granule" (granule).
Surfacing: — Gravel, 400-lbs/100-ft2, loose laid or applied in a flood coat of hot roofing asphalt.
2. Deck: NC Incline: 1/2
Base Sheet (Optional): — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop" (Smooth or
Granule) or "Ruberoid Mop Plus Granule ".
Coating: — "Karnak No. 97" applied at 11/2 to 3 -gal. /100 -ft2.
3. Deck: NC Incline: 1/4
Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, any thickness.
Base Sheet (Optional): — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop Granule" or
"Ruberoid Mop Plus Granule ".
Coating: — "Karnak No. 97" applied at 1' to 3 -gal /100 -ft2.
4. Deck: C -15/32 Incline: 1/2
Insulation: — One or more layers perlite, glass fiber, polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane
composite, phenolic, 11/2 -in. minimum thickness (butt joints staggered a minimum of 6 -in. form plywood deck butt joints).
Base Sheet: — One or more plies Type G2 or Type G3.
Ply Sheet (Optional): — One or more plies Type G1.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop" (Smooth or
Granule) or "Ruberoid Mop Plus Granule."
Surfacing: — "Karnak No. 97" applied at 11 to 3 -gal /100 -ft2.
5. Deck: NC Incline: 1/2
Base Sheet (Optional): — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus."
Surfacing (Optional): — Karnak "No. 97" or "169" applied at 1 to 3 gal /100 -ft2 or Grundy Ind. "20 F Emulsion" applied at 3 -gal /100 -ft2.
6. Deck: C -15/32 Incline: 1/2
Insulation: — One or more layers perlite, glass fiber, 3/4-in. minimum, polyisocyanurate, urethane, perlite /polyisocyanurate composite,
perlite /urethane composite, 1'/2 -in. minimum.
Base Sheet (Optional): — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop" (Smooth or
Granule) or "Ruberoid Mop Plus Granule."
Surfacing: — Gravel.
7. Deck: C -15/32 Incline: 1/2
Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite /polyisocyanurate
composite, perlite /urethane composite, wood fiber /polyisocyanurate composite.
Base Sheet: — Two or more plies Type G2 or Type G3.
Ply Sheet (Optional): — One or more plies Type G1.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop" (Smooth or
Granule) or "Ruberoid Mop Plus Granule."
Surfacing: — "Karnak No. 97" applied at 11/2 to 3 -gal /100 -ft2 or gravel.
httn• / /rlatahace 111 enm /nai- hin/XYV /temnlate /T .!SFXT /1 FR AMR /chnwnaae.html ?name =T... 5/21/2010
. ,TGFU.R1306 - Roofing Systems Page 9 of 48
8. Deck: NC Incline: 1/2
Insulation: — One or more layers perlite, glass fiber, 3 /4 -in. minimum polyisocyanurate, urethane, perlite /polyisocyanurate composite,
perlite /urethane composite, 11/2 in. minimum.
Base Sheet (Optional): — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid Torch" (Smooth or Granule) or "Ruberoid Torch Granule Plus" or "Ruberoid Mop" (Smooth or
Granule) or "Ruberoid Mop Plus Granule."
Surfacing: — Grundy "AL MB Aluminum Roof Coating" applied at 1 to 2 -gal /100 -ft2.
9. Deck: C -15/32 Incline: 1/2
Insulation (Optional): — One or more layers perlite, glass Fiber, 3 /4 -in. minimum, polyisocyanurate, urethane, perlite /polyisocyanurate
composite, perlite /urethane composite, phenolic, 11/2 in. minimum.
Base Sheet: — One or more plies Type G2 "GAFGLAS #75 Base Sheet ", or "Tri -Ply #75 Base Sheet ", hot mopped or mechanically fastened
in place.
Ply Sheet: — One or more plies Type G1 "GAFGLAS Ply 4 ", "Tri -Ply Ply 4 ", or "GAFGLAS Ply 6 ", hot mopped in place.
Membrane: — "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR ".
Surfacing — (Optional): "GAF Fibered Aluminum Coating" applied at 11/2- gal /100 -ft2 or "GAF Weather Coat Emulsion" applied at 3-
gal /100 -1t2.
10. Deck: C -15/32 Incline: 1/2
Insulation (Optional): — Perlite, fiber glass, polyisocyanurate, urethane or perlite /polyisocyanurate composite.
Base Sheet: — One or more layers Type G2 "GAFGLAS #75 Base Sheet" or "Tri -Ply #75 Base Sheet" or Type G3 "GAFGLAS Mineral
Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced Cap Sheet" hot mopped or mechanically fastened.
Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place.
Membrane: — "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR."
11. Deck: C -15/32 Incline: 1/2
Insulation (Optional): — Perlite, fiber glass, polyisocyanurate, urethane or perlite /polyisocyanurate composite, butt offset a minimum of
6 -in. from plywood deck joints.
Base Sheet: — One or more plies Type G2 "GAFGLAS #75 Base Sheet" or "Tri -Ply #75 Base Sheet" or Type G3 "GAFGLAS Mineral
Surfaced Cap Sheet" or 'Tri -Ply Mineral Surfaced Cap Sheet ", hot mopped or mechanically fastened.
Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place.
Membrane: — One ply "Ruberoid Torch Smooth" or "Ruberoid Mop Smooth "" or' "Ruberoid Dual Smooth."
Membrane: — One ply "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR."
12. Deck: NC Incline: 1
Insulation (Optional): — Perlite, fiber glass, wood fiber, polyisocyanurate, urethane or perlite /polyisocyanurate composite.
Base Sheet: — One or more layers Type G2 "GAFGLAS #75 Base Sheet" or "Tri -Ply #75 Base Sheet" or Type G3 "GAFGLAS Mineral
Surfaced Cap Sheet" or "Tri-Ply Mineral Surfaced Cap Sheet ", hot mopped or mechanically fastened.
Ply Sheet (Optional): — One or more plies Type G1 hot mopped in place.
Membrane: — One ply "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR."
13. Deck: NC Incline: 1/2
Insulation (Optional): — Perlite, fiber glass, wood fiber, polyisocyanurate, urethane or perlite /polyisocyanurate composite.
Base Sheet (Optional): — One or more plies Type G2 or Type G3 base sheet, hot mopped or mechanically fastened.
Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place.
Membrane: — One ply "Ruberoid Torch Smooth" (smooth) or "Ruberoid Mop Smooth" or "Ruberoid Dual Smooth."
Membrane: — One ply "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR ".
14. Deck: NC Incline: 1/2
Insulation (Optional): — One or more layers perlite, glass fiber, polyisocyanurate, urethane or perlite /polyisocyanurate composite, any
thickness.
Base Sheet: — One or more plies Type G1 "GAFGLAS Ply 4" or 'Tri -Ply Ply 4" or "GAFGLAS Ply 6" or Type G2 "GAFGLAS #75 Base Sheet"
or "Tri -Ply #75 Base Sheet" hot mopped or adhered with Karnak Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at
1'/2 -gal / 100 -ft2.
Membrane: — One ply "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR" hot mopped or adhered with Karnak
Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive applied at 11/2-gal /100 -ft2.
15. Deck: C -15/32 Incline: 1/2
Insulation (Optional): — Polyisocyanurate, wood fiber, perlite, glass fiber any thickness, hot mopped or mechanically fastened.
Base Sheet: — One or more plies Type G2 "GAFGLAS #75 Base Sheet " or 'Tri -Ply #75 Base Sheet" hot mopped or mechanically fastened.
Membrane: — One or more plies "Ruberoid 30 FR" or "Ruberoid EnergyCap SBS 30 FR" hot mopped in place.
httn: / /datahase.ul.com /cgi- hin/XYV /template /T,JSEXT /1 FRAME. /shownas?e.html ?name =T... 5/21/2010