MC-11-1567
Permit Number: MC -8 -11 -1567 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 163734 Inspection Date: February 27, 2012 Inspector: Perez, JanPierre Owner: EVERETT, HENRY Job Address: 9636 NE 2 Avenue Miami Shores, FL 33138- Project: <NONE> Contractor: DEBONAIR MECHANICAL, INC Permit Type: Mechanical - Commercial Inspection Type: Final Work Classification: A/C Replacement Phone Number (727)461 -4370 Parcel Number 1132060132500 Phone: 305 -826 -2240 Building Department Comments REMOVE AND REPLACE 5 AC UNITS 2 -5TON 1- 7.5TON 1 - 2.5TON 1- 1.5TON i 1 l'Z' Passed ER Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until For Inspections please call: (305)762 -4949 February 27, 2012 Page 1 of 1 AUG 2 6 2011 'i NOTICE OF COMMENCEMENT 11 R CORDED COPY MUST BE POSTED ON THE SITE AT TIME OF FIRST INSPECTION. F'Flf t f . TAX F ..10 NO, ik'ratig7s1X4Q ST OF FLORL *A: COUNrrpF mown/Pe THE UtJDERSIGNEb:fereby gives notice tkatfi7proyements will be made to ce property, and in accordance 3ulth Chapter: 713,. Florida Statutes, the .fo lowing fnf is provided in this Notice af Commencement: 111111111111 11111 1111111111 1111111111 11111111 CFN 2011R 0 15 32 -8 OR Bk 27814 Ps 3222; (1p ) RECORDED 09/06/2011 10:43:131 HARVEY RUVIN, CLERK OF COURT MIIA1I -DAC'E COUNTYr FLORIDA LAST PAGE COUP OF DADS RLORYD R11P1 that this is ,, ; ; copy of the P , ay of Mt D ca on fl ►� 20 : ? vote by /y; :atyeresenf tent of re oftica L Legal des tPiton U/ an 'a` add -rte /Pi 6 O'� ?LIP A1/: /14/;11-.1.44' .hGr/Y �o ".• "61/b // -0/.1__-d5" 2; Desert` Men. of imorovemerit: /fit/ . s. , 4ve r:r ; 3J6Qur (s)'5rie.anrvdder i eat �s Interest u°i:.propetty: Name and address of fee,simpte titleholder 4 name add = r>a phoneriurttber . SuretW (Payment bond required by owner from + r, if any) Nathe, aaddress and phone number; Amount Of band $ S. Lender's game and address: Persona within the State of Florida designated by Owner upon whom notices or otter documents-may 4e salved ars ProYkre0`by Section 713:13(1)(0)7., Florida State Name, address and gone number 1n addition to himself. Owners designates the, following person(s) to receive a copy of the Panes- Nitre as provided b i Serctiort 'f:3,130 Florida Statutes. Name; address and phone ntirtmber .Expiration date of this Notsce of Oortimenoernent (the,expitation .die is 1. ye iram the date:o f Fin?mitrts uNess a dit(ei'eit date Is spedflit ) WARNING TO OWNER: ANY PAYMEt fTS.WIDE $Y TIE OWNER AFTER THE EX Fl OF THE NOTICE OF GONNMENCEMENT ARECONsitrERED TMPROP1Bi PAYMENTS LINDER GHAFtER 713, FART l; SECTION:7M13i3. FLORIDA STATUTES AND OAN RESULT IN YOUR PAVING Ti i E FOR IMPBOVEAAENTu 1Tb YOUR PROPERTY -A NORM OF' ootommCEMENT MUST RE-RECORDED AND POSTED 0111 THE JOB SITE BEFORE. THE' FIFISTINSPEOTION IF YOU INTEND TO DB1NN =l NCING,.CONSIJLT.WITH YOUR i.ENDE i OR AN ATTORNEY BEFORE COMMENCI1 G WORK OR RECORDING YOUR-4011W it30 OONINIENCtIVIENE bf Prepared By Print Name TiiOiliee STPTi .E FL.ORJDA NV y %v at ja 1 OF' M . ° he'for. oing;instrurnent-:was. acknowledged before rile tills cIS 4 day of t-rai4ce I' . &ere. 7041ndhnefuaily..a., i as . 1 P t ohalby i noWn,. or I propuced the foiioWing type of tderttf(ication:: D4,.. ('3-2/-3 te SD- f o Prepared By Print Name Trtle/Offioe for lei 1.a A.• a Signature of Notary Public, ___„.L2/._ i rint Nettie: cta B. ♦ ,JIa . NW, State ie of Florida Aui nI Commission# EE 18652 m1'. exe8Au8 18, 2014 /Partner/Manager wt lgned a By (SEA 61.1 .ta Y. ., L11_ kinder penalties of perjury, i declare that 1 have read the foregoing and -that the .(acts stated In It Ara true, to he best of *.knowledge and belief. WIOnature(s) is) or t Owens)' ;r �ow 4ed Officer ,AAA' BY Mi1 Shores Village ol iiik _ tivAvil Building Department tom N.E.Ind Avenue, Miami Shot% Hewitt& 33.13g Tell Oft 1912/04 Fix: (Mb) 1361972 ItiSPECTIONV MOM NUMMI POS)10.4#49 WILD G PERMIT APPLICATION ne 20 .01,411kiEtt: Name (Fee InPle'titkbolder); niailte5 eperw Addreas.: RECEIVED AUG 2 4 2011 1Y. Permit NO. t 901 Mester Pernik No. Ow, lea" foar teratatILessee Name: --Jr- Emak. VP' Siate,—.6/ ritv .73*.9‘. JOB OD.RESSI tity: ftotiotRarcel* ibielfailding 11,Isturiett,IliResietinfetit YeS- Zone: Wan:a -,: ,,,,,,. 0,,,,,,,,,,;,,, ir :State Certification orRagistradon It: e 01:207 Certificate otGonmeteney 41,1 Contact Phone* 71-SS .7,4Z,-(6211 Emit Address: ,, DESIGNER: ArchitectiEngineer: Pima: ValuentliVork tor thisTerudtt * • t ,C10..40 stitureulat , fW� lok.*******44.aea..**aokaatooatavagir Submittal Pee $ , Penult r Seastulate Pee $ Radon D PRI Noteri.$ Doubk Fee $ - Structural Rte $ einnintni'aNatue (elm:Citable) Bonding •Compatoes Address :04 NfortpageLeadea ilarne0applicable) Mortgage Lenders Ad4tos City Zip Sate ziP- inhetebyi nude to :obtain a.permitto da the work and installations as im.ted 1 cettq that totvottoriitstalstiodhas commenced: prior to the issuartne.of a permit and that alt work milt he 'petfearced to ,meet the Omatartte et all laws regniating ca.Mtotatiraria,014:juriadiebert I understand -that a *SOO POta.ftlits:t be **OA :kr agcrwaWQR&rwmintn:,SKin MAMMA, kgce.i'MS, TANKS. atiti :()W2iNitir$:ArizIDAVIT: 1 cettifythat ill the foregoing information is .accorato :ant thatailvork will be done in compliance with alt applieabiehrwaregniatingitoinametiumant '4:WARNING- TO OVOIERt YOUR -FAILURE 'TO RECORD: A WATICE 010 cOWNcEMENT MAY RESULT IN YOUR tAyINO TWICE fog IMPROVEMENTS TO YOUR PROPERTY, IF YOU • INTEND TO OBTAIN :FINANCING* CONSULT wrni YOUR LENDER, OR AN ATTORNEY BEJ?ORE RwmpploYQUR NOTICE or COMMENCEMENT." Sake so Applicant: Asn contrition tnt c .ismance of a building permit with an estitnatettvalue:awcediteg $2504 the uPillicaui, proinise in good fitgi *at a copy notice of catninencentent cind cottninction rtaa Iaw s. will * *400 to 4414* prnpe.ry is *WO k 0.40-94Wn4 .41,Fkot a 400E4 ivit, If* *41*(10 #0414''.ili00. -Or #.*s(' be posled at t.1w -,tak . llw fisst - k 0004 woven .4itys afser ptulnit i. issacd. .1 She absent eit ffOttre ayei land a reinspectionfee will charged Ow0gf .tit g-04 'The foregointinstruntentwutocknoW - fore me this' ;.: The fo,-10 ,; ,,.,,,,u,A*,.{. t ac.1.,.- day of, A u‘fivi. , 2L, by. FRiaoaes A Evegerr dnfof .,.. '1... 01....i4.' A k.. by : 3tt;, akiL lhiho is PersonlittY kni*ViCi ft? itieo who bakproMmed Who ';! sonalty nown 0 ino dr *hi" hilt.l'pt - AS idgidifiMitikarid Whet did takean oath. td end/twat* tind wint:did: eon mak s- Sigat hint My COIntnitgAlit EXPirtg; 0 et /0 /2013 _Air.=11/71 JOSEPH L ANDRE MY COMMISSION* DD910824 EXPIRES: Sept. 6, 2013 ' ;1 Mk:Conn* -:****tt4**•*.***jsitia'jkn***itt**********St*. '" " • PPRVEIThY titevirga ovatvipanaltoottonnot My Home iniarni a a.gov Show Me: Property Information $earchBy Setect ttem • TeXt hale PtopetlyAtteettser T Property ekhatalser Tax IklitWan aiiitUr 4144setiw 4,. Ei1.5 • . " .. $ NtSAVE• - -,'-':",::::r,?:•;' '-'74174, 't4,-, . • . .. . .. s. . .. . . . . .. . . .4... • ASVESETT *SOON DR . ... _ . • ATER BEACH Fi- Stit' ... . .. .._ .. Intormatim a to WOL MommErn 3 i l'rra ma=mmuommoommorrommlo =wow inummume ;ta.S.12M it% so FT I.:416.1 Ste 1 AMID' ')D-10 LOTS 1-2 & et- later &Mt OPP • 464446 4 ittatOmMenthOwelanom Taxable Wee ltdannatiett: Tesinfleatteatei 04010 deafer $01 raptly -aces e tt Mehemet two, It" l'OMAiOrthvolimVj ffiltInkafff if lieu expettence technical diteeilltletteetth the erevtekto seed us YON emeettt* pleaseelesteueet4 htipti/gisitnamianida&govirnyhotne/propmap.asp 6122120 1 Proposal 31758R To: W.W. Gay Mechanical Contractors, Inc 524 Stockton St Jacksonville, Fl 32204 DebonAir Mechanical, Inc. Date: April 20, 2011 Location: Chase Bank, 9640 NE 2nd Ave Miami Shores, Fl Attention: James Fouraker Phone: 904 - 394 -7909 Email: jfouraker@wwgmc.com We hereby submit specifications and estimates for: Replacement of four (4) roof top package units for the main banking area and Carrier 2 ton air conditioning for the ATM room as follows: • Shut down units and lock /tag out service disconnects. • Provide crane for removal and installation. • Remove four (4) antiquated rooftop package air conditioning units and dispose of as per EPA guidelines. • Provide new units and curb adapters for each rooftop package unit to include outside air hood, electric heat and coil corrosion coating for condenser coil. • Reconnect all units to existing electrical. • Replace unit #1 five (5) ton side discharge rooftop package unit with Trane five (5) ton package unit on existing steel stand. • Provide new duct connection to existing ductwork. • Provide the following replacement units and adapter curbs for new units. Unit #2 five Trane (5) ton, #3 Trane seven and one half ton (7.5) and #4 Trane two and one half ton (2.5). • Install new units and connect to existing controls. • Replace 2 ton Carrier split system for the ATM room. • Remove one (1) antiquated air conditioning unit and dispose of as per EPA guidelines. • Recover refrigerant R -22 per EPA guidelines and regulations. • Installation of one (1) new sight glass moisture indicators, (1) new liquid line drier /dehydrator and 2 ton split system for the ATM room unit. • Pressurize system with dry nitrogen and leak check. • Evacuate system to remove moisture and non - condensable particles. • Recharge system with refrigerant R-410A (complete charge). • Start unit and verify proper operation of system. • Notify customer of any abnormalities noted after start up. • Prior service calls, code changes or upgrades not included in this proposal • Also includes necessary labor during normal working hours, permit, hauling, supervision, cleanup, and startup to complete all work inclusive of this agreement. Proposal 31758R DebonAir Mechanical, Inc. EXCEPTION: Shop Drawing, Engineering, Mechanical Drawings, Existing Controls, Existing Electrical, Fire System, Refrigerant Leaks in Unexposed Section or unit piping (i.e. underground) for air handler unit and or any unforeseen problems, etc. WARRANTY: Manufacturer to provide a limited warranty of five (5) years on compressor and one (1) year on parts, DebonAir to provide a one (1) year labor service during normal working hours. NOTE: Six (6) to eight (8) week lead time for equipment, DebonAir is not responsible for delay beyond listed lead time. PREVENTIVE MAINTENANCE EXCLUDED WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR - COMPLETE IN ACCORDANCE WITH THESE SPECIFICATIONS, FOR THE SLIM OF: Forty One Thousand One Hundred Thirty Dollars ..................... $41,130.00 Terms: 50 % payment due upon signing and remaining 50% due upon startup of equipment. Authorized Signature: ∎r , Toe Keller Date: April 21, 2011 Note: This proposal may be withdrawn by us if not accepted within (30) days. Proposal is subject to price increase after (30) days. Acceptance of Proposal: The prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. In the event DEBONAIR MECHANICAL, INC. employs an attorney to enforce this agreement or to collect any delinquent payments, customer agrees to pay all costs of court and reasonable attorney fees incurred or expended by DEBONAIR MECHANICAL, INC., including appeals. Approval Signature: Date: Printed: Date: DebonAir Mechanical, Inc. 2649 W 81 St. * Hialeah, Fi. 33016 * Dade (305) 826 -2240 * Toll Free 1- 800 - 447 -1562 * Fax (305) 826 -2966 CM C051447 2 DEBON -1 OP ID: IZ AWRU° 41.........-- CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DDNYYY) 08108/11 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POUCIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder is an ADDITIONAL INSURED, the policy(Ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER 305- 670 -6111 InSource, Inc. 9500 South Dadeland Blvd.,I400 305670 9699 P.O. Box 561567 Miami, FL 33256 -1567 William F. Kleis FACT William F. Kleis aO . Ext : 3056705336 AcFAX , No): 305470 4699 E-MAIL o SS: bkleis@insurace- inc.com INSURER(S) AFFORDING COVERAGE NAIC 0 INSURER A : Travelers Ind. Co. of America 19046 INSURED DebonAir Mechanical Inc. 2649 West 81 Street, Unit f/4 Hialeah, FL 33016 INSURER B: Travelers P & C of America 25674 INSURER C: Bridgefield Employers Ins. Co. 07/01/12 INSURER D : FCCI Commercial Ins. Co. 33472 INSURER E : $ 300,000 INSURER F: $ 5,000 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE N. • INSR SUBR wvn POLICY NUMBER POLICY EFF IMMIDDIYYYYI POLICY EXP IMMIDD/YYYY1 LIMITS A GENERAL X LIABILITY COMMERCIAL GENERAL LIABIUTI' CO2674R07A 07/01/11 07/01/12 EACH OCCURRENCE $ 1,000,00 DAMAGE TO RENTED PREMISES (Ea occurrence) $ 300,000 MED EXP (My one person) $ 5,000 CLAIMS -MADE X OCCUR PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP /OP AGG $ 2,000,000 GEM_ AGGREGATE UMIT APPLIES PER POLICY 56 I JFf`aT fl LOC $ A AUTOMOBILE _ X X ANY AUTO ALL OWNED AUTOS HIRED AUTOS X SCHEDULED AUTOS NON-OWNED BA2674R07A 07/01/11 07/01/12 COMBINED SINGLE UMIT (Ea accident) 1 _S______ , , $ BODILY INJURY (Per person) BODILY INJURY (Per accident) $ PROPERTY ent) AGE $ $ B X UMBRELLA LIAR EXCESS LU►B X OCCUR CLAIMS-MADE CUP2674R07A 07101/11 07/01/12 EACH OCURRENCE $ 5,000,000 AGGREGATE $ 5,000,000 $ DED I X 1 RETENTION $ 10000 C WORKERS COMPENSATION AND EMPLOYERS' UAB AND / N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) It e, describN e render DESsCRIPTIO OF OPERATIONS below N / A 083032773 10/30/10 10/30/11 X WC STATU- TORY LIMITS - OTH- °R EL EACH ACCIDENT $ 1,000,000 E.L DISEASE - EA EMPLOYEE $ 1,000,000 E.L DISEASE - POLICY LIMIT $ 1,000,000 D Equipment FItr 91,000 Deductible CM00055252 07/01/11 07101/12 Tools 30.000 Rent/Leas 80,E DESCRIPTION OF OPERATIONS 1 LOCATIONS 1 VEHICLES (Attach ACORD 101, Addklonal Remarks Schedule, U more apace Is required) City of Miami Shores tY Building Department 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -2304 1 CITY138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ��Qj� �"— ,a4 � rte ACORD 25 (2010105) © 1988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD TATE-OF FLORIDA, MIAMI -DADE COUNTY TAX COLLECTOR 140 W. FLAGLER ST. 1st FLOOR MIAMI, FL 33130 2011 LOCAL BUSINESS TAX RECEIPT 2012 MIAMI -DADE COUNTY - STATE OF FLORIDA EXPIRES SEPT. 30, 2012 MUST BE DISPLAYED AT PLACE OF BUSINESS PURSUANT TO COUNTY CODE CHAPTER 8A - ART. 9 & 10 261423 -9 _I'i 31;:: if aSs"YE A FALL - 130 NO PAY RENEWAL Bun alu vlii %C1IANICAL INC STATEB#BCEMG151447 2649 W 81 ST 33016 HIALEAH OWNER MECHANICAL INC SBCi_VDOMAR MECHANICAL THIS IS ONLY A LOCAL BUSINESS TAX RECEIPT. IT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING LAWS OF THE COUNTY OR CITIES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS IS NOT A CERTIFICATION OF THE HOLDER'S QUAUFICA- TIONS. PAYMENT RECEIVED MIAMI -DADE COUNTY TAX COLLECTOR: 07/12/2011 60060000237 000045.00 SEE OTHER SIDE CONTRACTOR WORKER /S 1 DO NOT FORWARD DEBONAIR MECHANICAL INC SUSAN ALESHIRE PRES 2649 W 81 ST HIALEAH FL 33016 I„ III, I III II,,,,,Ill,IJ,,,, I, Ii „II,i►II, Ii, I Ii, IIIIII, IjI, FIRST -CLAS; U.S. POSTAGI PAID MIAMI, FL PERMIT NO. 2: 274216 -2 • aegel Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC/1 I "i (6j This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. 3‘ Job Address (where the work is being done): 71' , i 01/ C i ..s e City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO J( ARHI Sheet Attached: YES P. ■/ NO ❑ Contract Attached: YES j-1 UNIT BEING REPLACED DATA NEW UNIT Leon 0y MANUF °' RER Zi-_,,,,,y®,e- <__ _- f S4 AHU or UNIT MODEL # COND. "` MODEL # �. KW HEAT -7, s— S NOM TONS S" AHU CU P 446 1) 2; M.C.A M.O.P AHU CU 4110 AHU CU at AHU CU 6I, AHU CU tl;l f�' zc m 3) VOLTS AHU CU zoir Y PKG UNIT / / PKG UNIT / / E -4 - A 5,- /0,0 EER/SEER / /..z -5 /3 E . likLI REPLACING DUCTS Y. ;;41(i , IS '+, REPLACING THERMOSTAT Y �0 NEW 4 °CONCRETE SLAB Y S` YES NEW ROOF STAND YES YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): 8 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 60 3. Voltage of Circuit (208/240/480): ®?®g --Lf 4. Size Disconnecting Means: oo v Contractor's Company Name: ? //®f /4e Phone6$Z� `0Z (40 State Certificate or Registration N. e/97t ®T1I¢ 1 Certificate of Competency N. Signature (Qualifier's signature only) Date: /Zvi/ t, Certificate of Product Ratings AHRI Certified Reference Number: 3015814 Date: 8/23/2011 Product: Single- Package Air - Conditioner, Air - Cooled Model Number: KCA060S4mP Manufacturer: LENNOX INDUSTRIES, INC. Trade /Brand name: LANDMARK Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 59000 EER Rating (Cooling): SEER Rating (Cooling): 13.00 Ratings followed by an asterisk (1 indicate a voluntary rerate of previously published data, unless accompanied wtth a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or perfommnce of the product(s), or the unauthorized alteration of data listed on tilts Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any font or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The infommtion for the model cited on this certificate can be verified at www.ahr(directory.org, click on "Verity Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute Air Conditioning, Heating, M®® and Refrigeration institute CERTIFICATE NO.: 129586048789256250 • Proposal 31758R To: W.W. Gay Mechanical Contractors, Inc 524 Stockton St Jacksonville, Fl 32204 DebonAir Mechanical, Inc. Date: April 20, 2011 Location: Chase Bank, 9640 NE 2nd Ave Miami Shores, Fl Attention: James Fouraker Phone: 904 -394 -7909 Email: jfouraker@wwgmc.com We hereby submit specifications and estimates for: Replacement of four (4) roof top package units for the main banking area and Carrier 2 ton air conditioning for the ATM room as follows: • Shut down units and lock /tag out service disconnects. • Provide crane for removal and installation. • Remove four (4) antiquated rooftop package air conditioning units and dispose of as per EPA guidelines. • Provide new units and curb adapters for each rooftop package unit to include outside air hood, electric heat and coil corrosion coating for condenser coil. • Reconnect all units to existing electrical. • Replace unit #1 five (5) ton side discharge rooftop package unit with Lennox five (5) ton package unit on existing steel stand. • Provide new duct connection to existing ductwork. • Provide the following replacement units and adapter curbs for new units. Unit #2 five Lennox(5) ton, #3 Lennox seven and one half ton (7.5) and #4 Lennox two and one half ton (2.5). • Install new units and connect to existing controls. • Replace 2 ton Carrier split system for the ATM room. • Remove one (1) antiquated air conditioning unit and dispose of as per EPA guidelines. • Recover refrigerant R -22 per EPA guidelines and regulations. • Installation of one (1) new sight glass moisture indicators, (1) new liquid line drier /dehydrator and 2 ton split system for the ATM room unit. • Pressurize system with dry nitrogen and leak check. • Evacuate system to remove moisture and non - condensable particles. • Recharge system with refrigerant R-410A (complete charge). • Start unit and verify proper operation of system. • Notify customer of any abnormalities noted after start up. • Prior service calls, code changes or upgrades not included in this proposal • Also includes necessary labor during normal working hours, permit, hauling, supervision, cleanup, and startup to complete all work inclusive of this agreement. Proposal 31758R DebonAir Mechanical, Inc. 1 EXCEPTION: Shop Drawing, Engineering, Mechanical Drawings, Existing Controls, Existing Electrical, Fire System, Refrigerant Leaks in Unexposed Section or unit piping (i.e. underground) for air handler unit and or any unforeseen problems, etc. WARRANTY: Manufacturer to provide a limited warranty of five (5) years on compressor and one (1) year on parts, DebonAir to provide a one (1) year labor service during normal working hours. NOTE: Six (6) to eight (8) week lead time for equipment, DebonAir is not responsible for delay beyond listed lead time. PREVENTIVE MAINTENANCE EXCLUDED WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR - COMPLETE IN ACCORDANCE WITH THESE SPECIFICATIONS, FOR THE SLIM OF: Terms: 50 % payment due upon signing and remaining 50% due upon startup of equipment. Authorized Signature: .� ■r'ldr foe Keller Date: April 21, 2011 Note: This proposal may be withdrawn by us if not accepted within (30) days. Proposal is subject to price increase after (30) days. Acceptance of Proposal: The prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. In the event DEBONAIR MECHANICAL, INC. employs an attorney to enforce this agreement or to collect any delinquent payments, customer agrees to pay all costs of court and reasonable attorney fees incurred or expended by DEBONAIR MECHANICAL, INC., including appeals. Approval Signature: Date: Printed: Date: DebonAir Mechanical, Inc. 2649 W 81 St. * Hialeah, Fl. 33016 * Dade (305) 826 -2240 * Toll Free 1- 800 - 447 -1562 * Fax (305) 826 -2966 CM C051447 2 9 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA II / PERMIT NUMBER: MC !' �) 5 6 This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. _36 / Job Address (where the work is being done): ,■ AM' cc5'J �. ct City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Disconnecting means: YES ❑ NO IX ARHI Sheet Attached: YES 11 NO ❑ Contract Attached: YES 14 UNIT BEING REPLACED DATA NEW UNIT G - ..� MANUFACTURER G - O- O ° AHU { UNIT MODEL # i1�.>1 COND.1 I T MODEL # KW HEAT NOM TONS AHU Cu 6 1 M.C.A AHU CU 4t AHU CU momil 2 M.O.P AHU CU l,, �2) CM, , ,, 3 VOLTS AHU CU PKG UNIT / / PKG UNIT / / EFL - Q 4( .5e.a. - fa 0 EERISEER C 1/, Z S -/3 Y. ,n s REPLACING DUCTS YES A fju I i„ REPLACING THERMOSTAT lu At YES vd1.., NEW 4 °CONCRETE SLAB A YES NEW ROOF STAND YES lirl YES le NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): 5 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 6 a 3. Voltage of Circuit (208/240/480): 'O ' 4. Size Disconnecting Means: 62 Contractor's Company Name: Phone: 0 za`z-2- 0' State Certificate or Registration N. c`we a5" 4'? Certificate of Competency N. Signature (Qualifier's s ' ature only) Date: /erZ�� Certificate of Product Ratings AHRI Certified Reference Number: 3015814 Date: 8/23/2011 Product: Single- Package Air - Conditioner, Air - Cooled Model Number: KCA060S4"'"'P Manufacturer: LENNOX INDUSTRIES, INC. Trade /Brand name: LANDMARK Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 59000 EE. R Ra..ting (Cooling).__.__ 11,.20 SEER Rating (Cooling): 13:00 Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory org, click on "Verily Certificate" link and enter the AHRI Certified Reference Number and the date on which the certfcate was Issued, which is listed above, and the Certificate No., which is listed below. 02011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: Air Condltfoning, Heating, NOM and Refrigeration Institute 129586048789256250 Froposal 31758R DebonAir Mechanical, Inc. To: W.W. Gay Mechanical Contractors, Inc 524 Stockton St Jacksonville, Fl 32204 Attention: James Fouraker Date: April 20, 2011 Location: Chase Bank, 9640 NE 2nd Ave Miami Shores, Fl Phone: 904 - 394 -7909 Email: jfouraker@wwgmc.com We hereby submit specifications and estimates for: Replacement of four (4) roof top package units for the main banking area and Carrier 2 ton air conditioning for the ATM room as follows: • Shut down units and lock /tag out service disconnects. • Provide crane for removal and installation. • Remove four (4) antiquated rooftop package air conditioning units and dispose of as per EPA guidelines. • Provide new units and curb adapters for each rooftop package unit to include outside air hood, electric heat and coil corrosion coating for condenser coil. • Reconnect all units to existing electrical. • Replace unit #1 five (5) ton side discharge rooftop package unit with Lennox five (5) ton package unit on existing steel stand. • Provide new duct connection to existing ductwork. • Provide the following replacement units and adapter curbs for new units. Unit #2 five Lennox(5) ton, #3 Lennox seven and one half ton (7.5) and #4 Lennox two and one half ton (2.5). • Install new units and connect to existing controls. • Replace 2 ton Carrier split system for the ATM room. • Remove one (1) antiquated air conditioning unit and dispose of as per EPA guidelines. • Recover refrigerant R-22 per EPA guidelines and regulations. • Installation of one (1) new sight glass moisture indicators, (1) new liquid line drier /dehydrator and 2 ton split system for the ATM room unit. • Pressurize system with dry nitrogen and leak check. • Evacuate system to remove moisture and non - condensable particles. • Recharge system with refrigerant R-410A (complete charge). • Start unit and verify proper operation of system. • Notify customer of any abnormalities noted after start up. • Prior service calls, code changes or upgrades not included in this proposal • Also includes necessary labor during normal working hours, permit, hauling, supervision, cleanup, and startup to complete all work inclusive of this agreement. Proposal 31758R DebonAir Mechanical, Inc. EXCEPTION :: Shop Drawing, Engineering, Mechanical Drawings, Existing Controls, Existing Electrical, Fire System, Refrigerant Leaks in Unexposed Section or unit piping (i.e. underground) for air handler unit and or any unforeseen problems, etc. WARRANTY: Manufacturer to provide a limited warranty of five (5) years on compressor and one (1) year on parts, DebonAir to provide a one (1) year labor service during normal working hours. NOTE: Six (6) to eight (8) week lead time for equipment, DebonAir is not responsible for delay beyond listed lead time. PREVENTIVE MAINTENANCE EXCLUDED WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR - COMPLETE IN ACCORDANCE WITH THESE SPECIFICATIONS, FOR THE SUM OF: Terms: 50 % payment due upon signing and remaining 50% due upon startup of equipment. Authorized Signature: 9. i foe Keller Date: April 21, 2011 Note: This proposal may be withdrawn by us if not accepted within (30) days. Proposal is subject to price increase after (30) days. Acceptance of Proposal: The prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. In the event DEBONAIR MECHANICAL, INC. employs an attorney to enforce this agreement or to collect any delinquent payments, customer agrees to pay all costs of court and reasonable attorney fees incurred or expended by DEBONAIR MECHANICAL, INC., including appeals. Approval Signature: Date: Printed: Date: DebonAir Mechanical, Inc. 2649 W 81 St. * Hialeah, Fl. 33016 * Dade (305) 826 -2240 * Toll Free 1- 800 - 447 -1562 * Fax (305) 826 -2966 CM C051447 2 Miami Shores village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA 1 t PERMIT NUMBER: MC l l �` This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. 36. �f Job Address (where the work is being done): 9‘## /1?� � � � -C# 5r'- City: Miami Shores Village County: Miami Dade Zip Code: 36, ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED ARHI Sheet Attached: YES, NO ❑ Contract Attached: YES Change Disconnecting means: YES ❑ NO UNIT BEING REPLACED DATA NEW UNIT _� MANUFACTURER " _ �� l 6 -e) D'2 AHU or UNIT MODEL # 4 ;gip',_ ;' ' COND. I I IT MODEL # __ KW HEAT - — NOM TONS AHU CU °' %LZ £ 1 M.C.A AHU CU '(t ' . AHU CU • < ..5-D, 2) M.O.P 3 VOLTS AHU CU - 6-c, AHU CU ' K ' z ®}r �1(c AHU CU , Zoe Ac-0 NIT / / P0_19NIT / / EER/SEER AZO - //, z, = -- ' iG d REPLACING DUCTS u: y„=AC r' `7 Kea t izmw REPLACING THERMOSTAT dr we NEW 4 °CONCRETE SLAB ME I El OP NEW ROOF STAND EMIIIE; YES NEW RETURN PLENUM BOX MEW NO 1. Minimum Circuit Ampacity (Wire Size): a 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/480): cAPl78°31ph 4. Size Disconnecting Means: 6I' C i v Contractor's Company Name: Phone: .7.0r —g4 - 2 z I{a State Certificate or Registration N. efii ! OS-432 Certificate of Competency N. Signature el-4X (Qualifier's signature only) Date: #Z0// Certificate of Product Ratings AHRI Certified Reference Number: 3632233 Date: 8/23/2011 tStatus: Active Product: Single- Package Air - Conditioner, Air - Cooled Model Number: KCA092S4B""Y,G,J Manufacturer: LENNOX INDUSTRIES, INC. Trade /Brand name: LANDMARK Rated as follows in accordance with AHRI Standard 340/360 -2007, Commercial and Industry Unitary Air - Conditioning and Heat Pump Equipment and subject to verification of rating accuracy by AHRI - sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): IEER: Heating Capacity at 47F (Btuh):: COP at 47F: Heating Capacity at 17F (Btuh): COP at 17F: 86000/86000 11.20/11.20 11.4/11.4 t Models with an 'Active' status are those that are currently in production. Models with a Discontinued status are those that the manufacturer has elected to stop producing, yet stock is still available. Models with an 'Obsolete' status are those that the manufacturer is required to stop manufacturing due to an AHRI certification program test failure. • Ratings followed by an asterisk (•) indicate a voluntary rerate of previously published data, unless accompanied with a WAS which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on thls Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The infomation for the model cited on this certificate can be verMed at vrww.anddirectory org, click on "Verify Certificate" Ilnk and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129586050968162500 Air - Conditioning, Healing, likE and Refrigeration Institute Proposal 31758R DebonAir Mechanical, Inc. To: W.W. Gay Mechanical Contractors, Inc 524 Stockton St Jacksonville, Fl 32204 Attention: James Fouraker Date: April 20, 2011 Location: Chase Bank, 9640 NE 2rid Ave Miami Shores, Fl Phone: 904 - 394 -7909 Email: jfouraker@wwgmc.com We hereby submit specifications and estimates far: Replacement of four (4) roof top package units for the main banking area and Carrier 2 ton air conditioning for the ATM room as follows: • Shut down units and lock /tag out service disconnects. • Provide crane for removal and installation. • Remove four (4) antiquated rooftop package air conditioning units and dispose of as per EPA guidelines. • Provide new units and curb adapters for each rooftop package unit to include outside air hood, electric heat and coil corrosion coating for condenser coil. • Reconnect all units to existing electrical. • Replace unit #1 five (5) ton side discharge rooftop package unit with Lennox five (5) ton package unit on existing steel stand. • Provide new duct connection to existing ductwork. • Provide the following replacement units and adapter curbs for new units. Unit #2 five Lennox(5) ton, #3 Lennox seven and one half ton (7.5) and #4 Lennox two and one half ton (2.5). • Install new units and connect to existing controls. • Replace 2 ton Carrier split system for the ATM room. • Remove one (1) antiquated air conditioning unit and dispose of as per EPA guidelines. • Recover refrigerant R -22 per EPA guidelines and regulations. • Installation of one (1) new sight glass moisture indicators, (1) new liquid line drier /dehydrator and 2 ton split system for the ATM room unit. • Pressurize system with dry nitrogen and leak check. • Evacuate system to remove moisture and non - condensable particles. • Recharge system with refrigerant R-410A (complete charge). • Start unit and verify proper operation of system. • Notify customer of any abnormalities noted after start up. • Prior service calls, code changes or upgrades not included in this proposal • Also includes necessary labor during normal working hours, permit, hauling, supervision, cleanup, and startup to complete all work inclusive of this agreement. Proposal 31758R DebonAir Mechanical, Inc. 1 EXCEPTION: Shop Drawing, Engineering, Mechanical Drawings, Existing Controls, Existing Electrical, Fire System, Refrigerant Leaks in Unexposed Section or unit piping (i.e. underground) for air handler unit and or any unforeseen problems, etc. WARRANTY: Manufacturer to provide a limited warranty of five (5) years on compressor and one (1) year on parts, DebonAir to provide a one (1) year labor service during normal working hours. NOTE: Six (6) to eight (8) week lead time for equipment, DebonAir is not responsible for delay beyond listed lead time. PREVENTIVE MAINTENANCE EXCLUDED WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR - COMPLETE IN ACCORDANCE WITH THESE SPECIFICATIONS, FOR THE SUM OF: Terms: 50 % payment due upon signing and remaining 50% due upon startup of equipment. Authorized Signature: ".e ,mss Joe Keller Date: April 21, 2011 Note: This proposal may be withdrawn by us if not accepted within (30) days. Proposal is subject to price increase after (30) days. Acceptance of Proposal: The prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. In the event DEBONAIR MECHANICAL, INC. employs an attorney to enforce this agreement or to collect any delinquent payments, customer agrees to pay all costs of court and reasonable attorney fees incurred or expended by DEBONAIR MECHANICAL, INC., including appeals. Approval Signature: Date: Printed: Date: DebonAir Mechanical, Inc. 2649 W 81 St. * Hialeah, FL 33016 * Dade (305) 826 -2240 * Toll Free 1- 800 - 447 -1562 * Fax (305) 826 -2966 CM C051447 2 amAl-Ifer Miami Shores village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA � PERMIT NUMBER: MC / t —15("4 (" This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): City: Miami Shores Village County: Miami Dade Lark Zip Code: 73 ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO IX ARHI Sheet Attached: YESt NO ❑ Contract Attached: YES UNIT BEING REPLACED DATA NEW UNIT ,' _-_-:-...,,o, MANUFACTURER _ - f� �1 O3o --Lie AHU UNIT MODEL # — COND. UNIT MODEL # — .. c KW HEAT 2. 5- Z- e Sr NOM TONS Z. S' AHU CU •' t S 1 M.C.A AHU CU 3-7 AHU CU ? * 2 MOP AHU CU /,;jr' AHU CU ' KG) 2 c 3 VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / EERISEER ,Eetz - /,: z 5. /5 S! REPLACING DUCTS ES . /i! Certificate of Product Ratin s AHRI Certified Reference Number: 3015797 Product: Single- Package Air - Conditioner, Air - Cooled Model Number: KCA030S4***P Manufacturer: LENNOX INDUSTRIES, INC. Trade /Brand name: LANDMARK Date: 8/23/2011 Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI - sponsored, independent, third party testing: Cooling Capacity (Btuh): 28800 EER Rating (Cooling): SEER Rating (Cooling): 13.00 * Ratings followed by an asterisk f7 indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. CertN'fed ratings are valid only for models and configurations listed In the directory at www.ahrtdirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of the Certificate may not, in whole or in part, be reproduced; copied; disseml; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www ahrldirectory org, click on "Verify Certificate" Zink and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which Is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129586050057693750 spy Air-Conditioning, Heating, NINE and Refrigeration institute Proposal 31758R To: W.W. Gay Mechanical Contractors, Inc 524 Stockton St Jacksonville, Fl 32204 DebonAir Mechanical, Inc. Date: April 20, 2011 Location: Chase Bank, 9640 NE 2nd Ave Miami Shores, Fl Attention: James Fouraker Phone: 904 - 394 -7909 Email: jfouraker@wwgmc.com We Hereby submit specifications and estimates for: Replacement of four (4) roof top package units for the main banking area and Carrier 2 ton air conditioning for the ATM room as follows: • Shut down units and lock /tag out service disconnects. • Provide crane for removal and installation. • Remove four (4) antiquated rooftop package air conditioning units and dispose of as per EPA guidelines. • Provide new units and curb adapters for each rooftop package unit to include outside air hood, electric heat and coil corrosion coating for condenser coil. • Reconnect all units to existing electrical. • Replace unit #1 five (5) ton side discharge rooftop package unit with Lennox five (5) ton package unit on existing steel stand. • Provide new duct connection to existing ductwork. • Provide the following replacement units and adapter curbs for new units. Unit #2 five Lennox(5) ton, #3 Lennox seven and one half ton (7.5) and #4 Lennox two and one half ton (2.5). • Install new units and connect to existing controls. • Replace 2 ton Carrier split system for the ATM room. • Remove one (1) antiquated air conditioning unit and dispose of as per EPA guidelines. • Recover refrigerant R -22 per EPA guidelines and regulations. • Installation of one (1) new sight glass moisture indicators, (1) new liquid line drier /dehydrator and 2 ton split system for the ATM room unit. • Pressurize system with dry nitrogen and leak check. • Evacuate system to remove moisture and non - condensable particles. • Recharge system with refrigerant R -410A (complete charge). • Start unit and verify proper operation of system. • Notify customer of any abnormalities noted after start up. • Prior service calls, code changes or upgrades not included in this proposal • Also includes necessary labor during normal working hours, permit, hauling, supervision, cleanup, and startup to complete all work inclusive of this agreement. Proposal 31758R DebonAir Mechanical, Inc. 1 EXCEPTION :: Shop Drawing, Engineering, Mechanical Drawings, Existing Controls, Existing Electrical, Fire System, Refrigerant Leaks in Unexposed Section or unit piping (i.e. underground) for air handler unit and or any unforeseen problems, etc. WARRANTY: Manufacturer to provide a limited warranty of five (5) years on compressor and one (1) year on parts, DebonAir to provide a one (1) year labor service during normal working hours. NOTE: Six (6) to eight (8) week lead time for equipment, DebonAir is not responsible for delay beyond listed lead time. PREVENTIVE MAINTENANCE EXCLUDED WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR - COMPLETE IN ACCORDANCE WITH THESE SPECIFICATIONS, FOR THE SUM OF: Terms: 50 % payment due upon signing and remaining 50% due upon startup of equipment. Authorized Signature: ■re/d, Joe Keller Date: April 21, 2011 Note: This proposal may be withdrawn by us if not accepted within (30) days. Proposal is subject to price increase after (30) days. Acceptance of Proposal: The prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be trade as outlined above. In the event DEBONAIR MECHANICAL, INC. employs an attorney to enforce this agreement or to collect any delinquent payments, customer agrees to pay all costs of court and reasonable attorney fees incurred or expended by DEBONAIR MECHANICAL, INC., including appeals. Approval Signature: Date: Printed: Date: DebonAir Mechanical, Inc. 2649 W 81 St. * Hialeah, Fl. 33016 * Dade (305) 826 -2240 * Toll Free 1 -800 - 447 -1562 * Fax (305) 826 -2966 CM C051447 2 Miami Shores village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): � 5 `z= ws e City: Miami Shores Village County: Miami Dade Zip Code: „7,367- ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO ARHI Sheet Attached: YES ❑ NO /3 Contract Attached: YES UNIT BEING REPLACED DATA NEW UNIT -4 ��e3k- MANUFACTURER r/-e_/ Z AHU or PKG. UNIT MODEL # © /c/AlG /Of -nave - 9A COND. UNIT MODEL # 3s//hp. ��� KW HEAT ...44,9.e- ,/, 5- NOM TONS /, 5- AHU [,6 CU /./ PKG 1) M.C.A AHU,S CU /z /PKG AHUN /A CU go PKG 2) M.O.P AHU /s- CU 20 PKG AHUr i- CU mr PKG 3) VOLTS AHU CU eat PKG PKG UNIT / / PKG UNIT / / 13, 0 - '// ,c-e EERISEER /'.3s / /,XE - YES 11i6► REPLACING DUCTS YES a _. ! REPLACING THERMOSTAT E •_ �� NEW 4°CONCRETE SLAB NEW ROOF STAND YES +�b-� YES 417 YES YES 1 0 ; NEW RETURN PLENUM BOX YES NO,/ 1. Minimum Circuit Ampacity (Wire Size): /pe 2. Maximum Overcurrent Protection (Fuse /Breaker Size): cgs 3. Voltage of Circuit (208/240/480): ao$ // 4. Size Disconnecting Means: ,3e70' Contractor's Company Name: c0Po7,i YiG /ieed State Certificate or Registration N. — .511- Certificate of Competency N. Signature (Quallfle s signets Phone: 3067---S/Z4 40KMC018 with 38HDF018 Preferred ,m Series - Cooling Only 13 SEER In- Ceiling Cassette Systems with Puron® Refrigerant ,lid ?,eS Turn to the Experts Job Data: Buyer: Buyer P.O.# Carrier # Unit Number. Performance Data Certified By: Submittal Data Location: Model Number. 4oiMIC 38HDF SYSTEM SIZE REFRIGERANT PERFORMANCE Nominal Capacity (Btuh) SEER Airflow (Low/Med/High) (CFM) SOUND PRESSURE (dBA) Indoor (Low/Med/High) Outdoor SOUND POWER (dBA) Indoor (Low/Med/High) Outdoor PERFORMANCE AT ACTUAL CONDITIONS: Attached ❑ Not Attached ❑ Date: FEATURES • Built -in condensate pump • Cleanable filter • Capable of conditioning an adjacent room • 2, 3, or 4 -way motorized louvers • Microprocessor controls with safeties and diagnostics • Auto restart after power failure • Wired or wireless user interface • User selectable fan speeds plus auto • Up to 6 units can be controlled with one wired controller • Low ambient to -20°F (with low ambient accessories) • Power ventilation accessory • Limited Warranty: 1 -year on all parts /5 -years on compressor • Optional extended parts and labor warranty Indoor Unit - 40KMC / Outdoor Unit - 38HDF (Unless otherwise indicated, data applies to both indoor and outdoor models) 018 ELECTRICAL R -410A 18,000 13 340 / 420 / 470 37/40/44 55 48/51/55 66 System Voltage MCA (Indoor) MCA (Outdoor) MOCP (Indoor) MOCP (Outdoor) Fan Motor (Indoor) (FLA) CONTROLS Control Remote (accessory) Wired or Wireless Control Voltage 24V Control Wiring (connection between indoor and outdoor units) 22 AWG REFRIGERANT LINES (Insulate both lines) Mixed Phase Line (in.) OD 3/8 Vapor Line (in.) OD 5/8 Metering/Control Device Accurater 'Refer to NEC and local codes for compliance requirements. 208/230 -1 VAC 0.8 12.1 15 20.0 0.55 Grate (in- ailing cassette) Mr Supply Outlet Obstruction Kit: Wired Room Control: Remote Control: Remote Control Locking Kit: Room Control Wiring Kit for Multiple Units: Zone Manager. Zone Manager Wring Kit Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Power Ventilation Kit Low Ambient Kit: Crankcase Heater: Winter Start Kit Wind Raffle: Slacking Kit: Wall Mounting RIO Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Proposal 31758R DebonAir Mechanical, Inc. To: W.W. Gay Mechanical Contractors, Inc 524 Stockton St Jacksonville, Fl 32204 Attention: James Fouraker Date: April 20, 2011 Location: Chase Bank, 9640 NE 2nd Ave Miami Shores, Fl Phone: 904 - 394 -7909 Email: jfouraker@wwgmc.com We hereby submit specifications and estimates for: Replacement of four (4) roof top package units for the main banking area and Carrier 2 ton air conditioning for the ATM room as follows: • Shut down units and lock /tag out service disconnects. • Provide crane for removal and installation. • Remove four (4) antiquated rooftop package air conditioning units and dispose of as per EPA guidelines. • Provide new units and curb adapters for each rooftop package unit to include outside air hood, electric heat and coil corrosion coating for condenser coil. • Reconnect all units to existing electrical. • Replace unit #1 five (5) ton side discharge rooftop package unit with Lennox five (5) ton package unit on existing steel stand. • Provide new duct connection to existing ductwork. • Provide the following replacement units and adapter curbs for new units. Unit #2 five Lennox(5) ton, #3 Lennox seven and one half ton (7.5) and #4 Lennox two and one half ton (2.5). • Install new units and connect to existing controls. • Replace 2 ton Carrier split system for the ATM room. • Remove one (1) antiquated air conditioning unit and dispose of as per EPA guidelines. • Recover refrigerant R-22 per EPA guidelines and regulations. • Installation of one (1) new sight glass moisture indicators, (1) new liquid line drier /dehydrator and 2 ton split system for the ATM room unit. • Pressurize system with dry nitrogen and leak check. • Evacuate system to remove moisture and non - condensable particles. • Recharge system with refrigerant R-410A (complete charge). • Start unit and verify proper operation of system. • Notify customer of any abnormalities noted after start up. • Prior service calls, code changes or upgrades not included in this proposal • Also includes necessary labor during normal working hours, permit, hauling, supervision, cleanup, and startup to complete all work inclusive of this agreement. Proposal 31758R DebonAir Mechanical, Inc. 1 EXCEPTION: Shop Drawing, Engineering, Mechanical Drawings, Existing Controls, Existing Electrical, Fire System, Refrigerant Leaks in Unexposed Section or unit piping (Le. underground) for air handler unit and or any unforeseen problems, etc. WARRANTY: Manufacturer to provide a limited warranty of five (5) years on compressor and one (1) year on parts, DebonAir to provide a one (1) year labor service during normal working hours. NOTE: Six (6) to eight (8) week lead time for equipment, DebonAir is not responsible for delay beyond listed lead time. PREVENTIVE MAINTENANCE EXCLUDED WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR - COMPLETE IN ACCORDANCE WITH THESE SPECIFICATIONS, FOR THE SUM OF: Terms: 50 % payment due upon signing and remaining 50% due upon startup of equipment. Authorized Signature: "re, Joe Keller Date: April 21, 2011 Note: This proposal may be withdrawn by us if not accepted within (30) days. Proposal is subject to price increase after (30) days. Acceptance of Proposal: The prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. In the event DEBONAIR MECHANICAL, INC. employs an attorney to enforce this agreement or to collect any delinquent payments, customer agrees to pay all costs of court and reasonable attorney fees incurred or expended by DEBONAIR MECHANICAL, INC., including appeals. Approval Signature: Date: Printed: Date: DebonAir Mechanical, Inc. 2649 W 81 St. * Hialeah, Fl. 33016 * Dade (305) 826 -2240 * Toll Free 1- 800 - 447 -1562 * Fax (305) 826 -2966 CM C051447 2 LENNOX Product Submittal Project Information Project Name: Chase Miami Shores Project Number: 3000224479 Project Location: NE 2ND AV MIAMI SHORES, FL 33316, US Project Altitude: 5 Customer Information Company Name: Debonair Mechanical Company Address: 2649 W 81 St Company Location: Hialeah, FL 33016 Contact: Phone: 305- 826 -2240 Engineering Information Company Name: Company Address: Company Location: Contact: Phone: We are pleased to provide the attached project submittal If you have any questions or need additional information, please feel free to call our office. Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 1 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description KC.A.06OSf. EE/5 TON /234 -1 UNIT #2 1 KCA060S4B P PKGEE /5 TON /230 -1 UNIT #4 1 KCA030S4D '15TON/230 -3 PKGEE /2.5 TON /230 -1 Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 2 of 23 Last Changed: DON SCHUTFE Prepared On: 2011 -07 -29 Phone: 954 - 610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #1 Package Model: KCA060S4B Description: P PKGEE /5 TON/230 -1 HEATING PERFORMANCE Heat Source H/E HighOutput System HeatOutput Electric 19235 (Btuh) 19235 (Btuh) Electric Heater H/E Heat Rise 7.5 (kW) 8.9 ( °F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 11.2 13.0 5300 (W) 61800 (Btuh) 59000 (Btuh) 61800 (Btuh) 59164 (Btuh) 44496 (Btuh) 41860 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 0.75 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 58.9 ( °F) 56.8 ( °F) 60.2 ( °F) 57.3 ( °F) 16.3 (lb/hr) 16.3 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2000 (cfm) 2000 (cfin) 0.20 ( in.WC) 0.84 (hp) 1.50 (hp) CAV Belt Drive 1032 (rpm) 833 (rpm) 1250 (rpm) TotalStaticPress Electric H/E Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.38 (in.WC) 0.18 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 208V 1Ph 60 (Hz) 48.0 (amp) 60 (amp) 26.4 (amp) 39.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 11.0 (amp) 2.4 (amp) 370 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 83.3 (in.) 36.4 (in.) 596 (lb) 19.5 (in.) 20.0 (in.) Horizontal Return Height Horizontal Return Width 11.0 (in.) 29.0 (in.) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 3 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #1 Package Model: KCA060S4B Description: P PKGEE/5 TON/230 -1 SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Expansion Valves High Capacity Driers Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED 2 IN MERV4 FILTER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 16W88 14W32 17W98 1 1 T 1 DAMP 11 A -1 OAD- MANUAL/HOOD,3 -6TON T SHT T1EH0075AN1P 7.5KW 208/230 -1 C1F4F060AN1P FUSE BLOCK KIT Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 4 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 -610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #1 Package Model: KCA060S4B Description: P PKGEE /5 TON/230 -1 DIMENSIONS - INCHES (MM) Model No. CORNER AA Base lbs. kg WEIGHTS Max. Ibs. kg BB Base Ibs. kg Max. Ibs. kg CC Base Ibs. kg Max. Ibs. kg DD Base Ibs. kg Max. Ibs. kg CENTER OF Base In. mm GRAVITY EE Max. In. mm FF Base In. mm Max. (n. mm 024 86 39 109 50 104 47 123 56 167 76 199 90 138 63 176 80 38-1/2 978 40 1016 18 457 18 457 030 86 39 109 50 104 47 124 56 168 76 199 91 138 63 176 80 38-1/2 978 40 1016 18 457 18 457 036 88 39 110 50 105 48 124 56 169 77 200 91 139 63 177 80 38-1/2 978 40 1016 18 457 18 457 048 93 42 116 53 112 51 132 60 181 82 212 96 149 187 85 38-1/2 978 40 1016 18 457 18 457 060 98 44 172 56 119 54 138 63 191 87 223 101 157 72 197 90 38-1/2 978 40 1016 18 457 18 457 072 115 52 136 83 139 63 156 71 225 102 251 114 185 84 222 101 38-1/2 978 40 1016 18 457 18 457 090 164 74 187 85 179 81 203 92 221 100 252 114 203 92 231 105 47 11-94 47 1194 21 533 21 533 Base Unit - The unlwith NO OPTIONS. Ma*. Unit - The unit with ALL OPTIONS Instead. (Economizer. etc.) 45 1"---(1143) p001==1 =1 001 47 BASE BASE END VIEW Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 5 of 23 5.518 (143) 29 47 ( 192) BASE 8. S� Cea mL 3 -1/ DD 11 a (413) (457) (279) BOTTOM I 5(102) RETURN OPENING AIR BOTTOM (508) SUPPLY AIR OPENING 6.518 (168) FF CENTER OF GRAVITY 46\ 25.314 (654) 024 thru 072 38 314 (984) 090 9 -'U2 (241) 26-1/2 (673) BOTTOM CONDENSATE OUTLET BB CC EE BOTTOM POWER ENTRY 3X8(76X203) TOP VIEW (Base) 831!4 (2115)024 thru 072 .( 96.114 (2445) 090 _I 28 -112 (673) —s UFTING HOLES 85 -114 (2165) 024 thru 072 BASE (Fa rigging) 98 -1/4 (2496) 090 BASE SIDE VIEW 11 19. 12_,_,183/8 (2e (495) (467) 1 2(51) 1 (25) 1 1l il1 i1llI ll 'll ICI HI 270- i II 1111 11111 (1) O 00 /Y-'-f\'==' —� /001 FORKUFT SLOTS 5.112 HORIZONTAL HORIZONTAL 5.12 (Front. owerEnd)� (140) OPENING RETURN AIR (140) (Without Economizer) 7 29 (737) i BACK VIEW Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 CONDENSATE OUTLET (EITHER SIDE) t11/02) ELECTRICAL INLET II III'1 r it I II 't 1 28 -112 (673) —s UFTING HOLES 85 -114 (2165) 024 thru 072 BASE (Fa rigging) 98 -1/4 (2496) 090 BASE SIDE VIEW 11 19. 12_,_,183/8 (2e (495) (467) 1 2(51) 1 (25) 1 1l il1 i1llI ll 'll ICI HI 270- i II 1111 11111 (1) O 00 /Y-'-f\'==' —� /001 FORKUFT SLOTS 5.112 HORIZONTAL HORIZONTAL 5.12 (Front. owerEnd)� (140) OPENING RETURN AIR (140) (Without Economizer) 7 29 (737) i BACK VIEW Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #1 Package Model: KCA060S4B Description: P PKGEE /5 TON/230 -1 OUTDOOR AIR DAMPER HOOD DETAIL FOR OPTIONAL MANUAL OR MOTORIZED OUTDOOR AIR DAMPERS (Downflow or Horizontal Applications) nI2_ OUTDOOR AIR DAMPER HOOD (Furnished) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 6 of 23 SIDE VIEW OPTIONAL OUTDOOR AIR DAMPERS AND PANEL 35 (889 OUTDOOR AIP DAMPER HOOD 35 (889) 024 thru 060 43(1092) 072 and 090 16-112 (419) 101,2 (267) Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610 -6156 OUTDOOR AIR DAMPER HOOD (Furnished) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 6 of 23 SIDE VIEW OPTIONAL OUTDOOR AIR DAMPERS AND PANEL 35 (889 OUTDOOR AIP DAMPER HOOD 35 (889) 024 thru 060 43(1092) 072 and 090 16-112 (419) 101,2 (267) Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #1 Package Model: KCA060S4B Description: P PKGEE/5 TON /230 -1 UNIT CLEARANCES - INCHES (MM) C OUTDOOR AR HOOO 4— D A 1 Unit Clearance in. A mm in. B mm in. C mm in. D mm Top Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required dearance for proper unit operation. Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 7 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #2 Package Model: KCA060S4B Description: P PKGEE/5 TON/230 -1 HEATING PERFORMANCE Heat Source Electric H/E HighOutput 19235 (Btuh) System HeatOutput 19235 (Btuh) Electric Heater H/E Heat Rise 7.5 (kW) 8.9 ( °F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 11.2 13.0 5300 (W) 61800 (Btuh) 59000 (Btuh) 61800 (Btuh) 59478 (Btuh) 44496 (Btuh) 42174 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 0.75 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 58.9 ( °F) 56.8 ( °F) 60.0 ( °F) 57.3 ( °F) 16.3 (lb/hr) 16.3 ( lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2000 (cfm) 2000 (cfm) 0.20 ( in.WC) 0.74 (hp) 1.50 (hp) CAV Belt Drive 1017 (rpm) 833 (rpm) 1250 (rpm) TotalStaticPress Electric H/E Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.38 (in.WC) 0.18 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 208V 1Ph 60 (Hz) 48.0 (amp) 60 (amp) 26.4 (amp) 39.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 11.0 (amp) 2.4 (amp) 370 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 83.3 (in.) 36.4 (in.) 596 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 18.0 (in.) 20.0 (in.) 11.0 (in.) 29.0 (in.) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 8 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #2 Package Model: KCA060S4B Description: P PKGEE/5 TON /230 -1 SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Expansion Valves High Capacity Driers Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED 2 IN MERV4 FILTER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 16W88 14W32 17W98 1 1 1 TIDAMP11A -1 OAD- MANUAL/HOOD,3 -ETON T SHT T1EH0075AN1P 7.5KW 208/230 -1 C1F4F060AN1P FUSE BLOCK KIT Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 9 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #2 Package Model: KCA060S4B Description: P PKGEE/5 TON /230 -1 DIMENSIONS - INCHES (MM) Model No. CORNER AA Base lbs. kg WEIGHTS Max. Ibs. kg BB Base Ibs. kg Max. Ibs. kg CC Base lbs. kg Max. Ibs. kg DD Base Ibs. kg Max. Ibs. kg CENTER OF Base In. mm GRAVITY EE Max. In. mm FF Base In mm Max. In. mm 024 86 39 109 50 104 47 123 56 167 76 199 90 138 63 176 80 38-1/2 978 40 1016 18 457 18 457 030 86 39 109 50 104 47 124 56 168 76 199 91 138 63 176 80 38-1/2 978 40 1016 18 457 18 457 036 86 39 110 50 105 48 124 56 169 77 200 91 139 63 177 80 38-1/2 978 40 1016 18 457 18 457 048 93 42 116 53 112 51 132 60 181 82 212 96 149 68 187 85 38-1/2 978 40 1016 18 457 18 457 060 98 44 122 56 119 54 138 63 191 87 223 101 157 72 197 90 38-1/2 978 40 1016 18 457 18 457 072 115 52 138 63 139 63 156 71 225 102 251 114 185 84 222 101 38-1/2 978 40 1016 18 457 18 457 090 164 74 187 85 179 81-20a 92 221 100252 114 203 92 231 105 47 1f94 47 1194 21 533 21 533 Base Unit - The unit with NO OPTIONS. Max. Unit The unit with ALL OPTIONS Insfatled. (Economizer. etc.) 45 8o o PE 1 (25) loot I I i oo 47 (1192) BASE END VIEW Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 10 of 23 5-5/8 (143) AA 7 (178) 16-1/4 18 (413) (457) 47 ( 192) BASE 29 ( 7) BOTTOM RETURN / AIR OPENING BOTTOM SUPPLY AIR OPENING 5(102) CENTER OF GRAVITY DD 6.518..L (168) 26 -1/2 (673) BOTTOM CONDENSATE OUTLET EE BOTTOM POWER ENTRY 3X8(76X203) TOP VIEW (Base) 83-114(2115)024 thru 072 961/4 (2445) 090 00 BB CC 26 -1 /2 (673) —► LIFTING HOLES 85 -1/4 (2185) 024 thru 072 BASE (Fa rigging) 98 -1/4 (2496) 090 BASE SIDE VIEW 11 X19 -1f2 (495) (467) 1 2(51) 11 ICI 1IIIII I III ICI II lijl� III it 0 L/ I `\r= 0 / FORKLIFT SLOTS (Front Back and Blower End) 7 29 (737) 1 5.1/2 HORIZONTAL HORIZONTAL 5-1/2 (140) SUPPLY AIR RETURN AIR (140) OPENING OPENING (Without Economizer) BACK VIEW Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 -610 -6156 CONDENSATE OUTLET (EITHER SIDE) I (140) ELE IN ! G TRICAL /LEr I I I I III'�- III] II 1I I 00 BB CC 26 -1 /2 (673) —► LIFTING HOLES 85 -1/4 (2185) 024 thru 072 BASE (Fa rigging) 98 -1/4 (2496) 090 BASE SIDE VIEW 11 X19 -1f2 (495) (467) 1 2(51) 11 ICI 1IIIII I III ICI II lijl� III it 0 L/ I `\r= 0 / FORKLIFT SLOTS (Front Back and Blower End) 7 29 (737) 1 5.1/2 HORIZONTAL HORIZONTAL 5-1/2 (140) SUPPLY AIR RETURN AIR (140) OPENING OPENING (Without Economizer) BACK VIEW Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 -610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #2 Package Model: KCA060S4B Description: P PKGEE/5 TON/230 -1 OUTDOOR AIR DAMPER HOOD DETAIL FOR OPTIONAL MANUAL OR MOTORIZED OUTDOOR AIR DAMPERS (Downflow or Horizontal Applications) 1a1n F. (zs7) O 0 O OUTDOOR AIR DAMPER HOOD (Furnished) Project: 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 11 of 23 SIDE VIEW OPTIONAL OUTDOOR _` AIR DAMPERS AND PANEL OUTDOORAIP DAMPER HOOD (419) Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #2 Package Model: KCA060S4B Description: P PKGEE/5 TON/230 -1 UNIT CLEARANCES - INCHES (MM) C OUTDOOR AR M000 D —► frcto A 1 Unit Clearance in. A mm in. B mm in. C mm in. D mm Top Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 12 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #3 Package Model: KCA092S4B Description: PKGEE/7.5TON/230 -3 HEATING PERFORMANCE Heat Source Electric H/E HighOutput 19235 (Btuh) System HeatOutput 19235 (Btuh) COOLING PERFORMANCE Electric Heater H/E Heat Rise 7.5 (kW) 5.9 ( °F) Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 11.2 11.4 7700 (W) 88900 (Btuh) 86000 (Btuh) 88900 (Btuh) 87872 (Btuh) 64008 (Btuh) 62980 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 59.8 ( °F) 57.3 ( °F) 60.1 ( °F) 57.4 ( °F) 23.5 ( lb/hr) 23.5 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 3000 (cfm) 3000 (cfin) 0.25 (in.WC) 0.32 (hp) 2.00 (hp) CAV Belt Drive 693 (rpm) 590 (rpm) 890 (rpm) TotalStaticPress Wet Coil Static Press Electric H/E Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.42 (in.WC) 0.11 (in.WC) 0.06 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 208V 3Ph 60 (Hz) 42.0 (amp) 50 (amp) 26.2 (amp) 38.5 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 7.5 (amp) 4.8 (amp) 670 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 992 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) Project: 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 13 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #3 Package Model: KCA092S4B Description: PKGEE /7.5TON/230 -3 SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Expansion Valves High Capacity Driers Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED 2 IN MERV4 FILTER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 53W48 56W38 1 1 C1DAMP10B -1 MANUAL OAD C1EH0075B -1Y 7.5KW 208/230 -3 ELEC HT Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 14 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #3 Package Model: KCA092S4B Description: PKGEE /7.5TON/230 -3 DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. Ibs. kg lbs. kg Ibs. kg lbs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm 092 236 107 282 128 212 96 246 112 231 105 263 119 263 119 308 140 46.5 1181 45.5 1181 24.5 622 25.5 648 102 241 109 287 130 217 98 250 114 236 107 268 122 268 122 314 142 46.5 1181 45.5 1181 24.5 622 25.5 648 120 251 114 299 135 226 102 261 118 246 111 279 127 279 127 327 148 46.5 1181 45.5 1181 24.5 622 25.5 648 150 274 124 322 146 246 112 281 128 268 121 301 136 305 138 352 160 46.5 1181 45.5 1181 24.5 622 25.5 648 Base Unit - The unit with NO OPTIONS Max Unit - The untt with ALL OPTIONS Installed. (Economizer, etc.) 8.1/8 (15) AA 60.1/8 (1527) BASE BOTTOM POWER ENTRY 5.1/2 (140) Dia. 58-178 (1476) • 100 = 0 601 60.1/8 (1527) END VIEW I 46-7/8 (1191) 43.318 (1102) 1 43.1/2 (89) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 15 of 23 24 (810) 27 (886) 103/4 (273) 20 (711) (508) 5418 BOTTOM SUPPLY (1+ > AIR OPENING 28 CENTER OF GRAVITY BOTTOM RETURN AIROPENING �� 11 7 (178) • DD (21 5) ELECTRIC INLETS 15-1/2 (394) 6.5/8 (168) 7 (178) 34.7/8 (886) FF BOTTOM CONDENSATE 101-1/4 BASE (2572) TOP VIEW 99-1/4 (2521) OPTIONAL DISCONNECT (FACTORY INSTALLED) BB CC 7 7 JCONDENSATE — DRAIN (FRONT) 531) (137) I II 34 -7/8 (886) FORKLIFT SLOTS ROTH SIDES) LIFTING HOLES (FOR RIGGING) 101 -1/4 (2572) SIDE VIEW 15-1/2 (394) ■ 11 HORIZONTAL SUPPLY AIR OPENING HORIZONTAL RETURN AIR OPENING CONDENSATE DRAIN (BACK) 431-1 /2 _�� 30 ,__• (800) p62) 66-3/8 (1686) 48.7/8 (1191) 1 1 -5/8 (41) 30 t782) 12 -1/8 001 (308) 5-318 (137) SIDE VIEW (Horizontal Openings) Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #3 Package Model: KCA092S4B Description: PKGEE/7.5TON/230 -3 ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21 -318 (543) OUTDOOR AIR HOOD (Furnished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished, Feld Installed) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 16 of 23 - lII. 0 000 'I II 10o I=1 CI 001 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610-6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #3 Package Model: KCA092S4B Description: PKGEE/7.5TON/230 -3 UNIT CLEARANCES - INCHES (MM) OPTIONAL OUTDOOR AIR HOOD i ' Unit Clearance A B C D Top Clearance In. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 914 60 1524 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unft base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable pans. Minimum Operation Clearance - Required clearance for proper unit operation. Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 17 of 23 Last Changed: DON SCHt1TTE Prepared On: 2011 -07 -29 Phone: 954-610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #4 Package Model: KCA030S4D Description: PKGEE /2.5 TON /230 -1 HEATING PERFORMANCE Heat Source H/E HighOutput System HeatOutput Electric 19235 (Btuh) 19235 (Btuh) Electric Heater H/E Heat Rise 7.5 (kW) 17.8 ( °F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 11.2 13.0 2600 (W) 29800 (Btuh) 28800 (Btuh) 30528 (Btuh) 29734 (Btuh) 25412 (Btuh) 24617 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 0.75 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 60.1 ( °F) 58.8 ( °F) 60.7 ( °F) 59.1 ( °F) 4.8 (lb/hr) 4.8 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDrive Speed 1208 (cfm) 1208 (cfm) 0.15 (in.WC) 0.25 (hp) 025 (hp) CAV Direct Drive 3 TotalStaticPress Electric H/E Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.18 (in.WC) 0.03 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 208V 1Ph 60 (Hz) 37.0 (amp) 40 (amp) 14.1 (amp) 17.5 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 1.7 (amp) 1.7 (amp) 250 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 83.3 (in.) 36.4 (in.) 528 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 18.0 (in.) 20.0 (in.) 11.0 (in.) 29.0 (in.) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 18 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954-610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #4 Package Model: KCA030S4D Description: PKGEE/2.5 TON /230 -1 SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Expansion Valves High Capacity Driers Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED 2 IN MERV4 FILTER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 16W88 14W32 17W94 1 1 1 T 1 DAMP 11 A -1 OAD-MANUAL/HOOD,3-6TON T SHT T1EH0075AN1P 7.5KW 208/230 -1 C1F4F035AN1P FUSE BLOCK KIT Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 19 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 Lennox Industries Inc. - Product Submittal System ID: UNIT #4 Package Model: KCA030S4D Description: PKGEE /2.5 TON/230 -1 DIMENSIONS - INCHES (MM) Model No. CORNER AA Base lbs. kg WEIGHTS Max. lbs. kg BB Base lbs. kg Max. Ibs. kg CC Base lbs. kg Max. Ibs. kg DD Base Ibs. kg Max. Ibs. kg CENTER OF Base In. mm GRAVITY EE Max. in. mm FF Base in. mm Max. In. mm 024 86 39 109 50 104 47 123 56 167 76 199 90 138 63 176 80 38-1/2 978 40 1016 18 457 18 457 030 86 39 109 50 104 47 124 56 168 76 199 91 138 63 176 80 38-1/2 978 40 1016 18 457 18 457 036 86 39 110 50 105 48 124 58 169 77 203 91 139 63 177 80 38-1/2 978 40 1016 18 457 18 457 048 93 42 116 53 112 51 132 60 181 82 212 96 149 68 187 85 38-1/2 978 40 1016 18 457 18 457 060 98 44 122 56 119 54 138 63 191 87 223 101 157 72 197 90 38-1/2 978 40 1016 18 457 18 457 072 115 52 138 63 139 63 156 71 225 102 251 114 185 84 222 101 38-1/2 978 40 1016 18 457 18 457 090 164 74 187 85 179 81 203 92 221 1M-252 114 203 92-231 105 47 1194 47 1194 21 533 21 533 Base Unit - The unit with NO OPTIONS. Max. Unit- The unit with ALL OPTIONS InstaAed. ( Economizer. etc.) 45 14--(1143) I1 (25) 100 = E 001 47 (1152) BASE END VIEW §220 S^ w Project: 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 20 of 23 5.5/8 (143) AA 7 (178) 47( 192) BASE 11 (279) 16-1/4 18 (413) (457) 29 7) 00 2 ao mL 3 -1/ DD BOTTOM RETURN / AIR OPENING BOTTOM (508) SUPPLY AIR OPENING 5(102) 65/8. _ (168) :> FF CENTER OF GRAVITY 25.3/4 (654) 024 t ru 072 26 -12 (673) BOTTOM CONDENSATE OUTLET —EE BOTTOM POWER ENTRY 3X8(76X203) TOP VIEW (Base) 83.1/4 (2115)024 thru 072 I~ 961/4 (2445) 090 L CONDENSATE OUTLET (EITHER SIDE) I 2 (14061) ELECTRICAL IN (.7 LET 1 1 I 11 I 1111 II �I i I I I I 26-32 (673) —1.- BB CC 14'5) r1 pc LIFTING HOLES I 85-1/4 (2165) 024 Um 072 BASE (For rigging) .. 98 -1/4 (2496) 090 BASE SIDE VIEW 11 x_18- 12y�,,,163/8 s A279), (485) (487) I 2 51) FORKUFT SLOTS (Front. Back and Blower End) 20 (508) 1 29 (737) i 5.12 HORIZONTAL HORIZONTAL 5.1/2 (140) SUPPLY AIR RETURN AIR (140) OPENING OPENING (Withcul Economizer) BACK VIEW Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954- 610 -6156 4 • Lennox Industries Inc. - Product Submittal System ID: UNIT #4 Package Model: KCA030S4D Description: PKGEE /2.5 TON /230 -1 OUTDOOR AIR DAMPER HOOD DETAIL FOR OPTIONAL MANUAL OR MOTORIZED OUTDOOR AIR DAMPERS (Downflow or Horizontal Applications) 10-1 /2 (267) • O OUTDOOR AIR DAMPER HOOD (Furnished) Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 21 of 23 SIDE VIEW 00 35 OPTIONAL OUTDOOR AIR DAMPERS _+ AND PANEL OUTDOORAIP DAMPER HOOD (689 131/2 `(343) 16.12 11°° 10-1/2 (267) (419) Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 35 (889) 024 thru 060 43 (1092) 072 and 090 Lennox Industries Inc. - Product Submittal System ID: UNIT #4 Package Model: KCA030S4D Description: PKGEE/2.5 TON/230 -1 UNIT CLEARANCES - INCHES (MM) 1 Unit Clearance In. A mm in. B mm in. C mm in. D mm Top Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 22 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156 4 `. Lennox Industries Inc. - Product Submittal NIISCELLANEOUS MATERIALS COMSD Third Party SC ADAP CURB CHA16 -060 TO KC COMSD Third Party SC ADAP CURB CHA16 -090 TO KC COMSD Third Party SC ADAP CURB CHA16 -030 TO KC Project 3000224479 Chase Miami Shores Quote: 4000266325 Chase Miami Shores Page 23 of 23 Last Changed: DON SCHUTTE Prepared On: 2011 -07 -29 Phone: 954 - 610 -6156