Loading...
RF-11-2344Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 168076 Permit Number: RF -12 -11 -2344 Scheduled Inspection Date: February 15, 2012 Inspector: Bruhn, Norman Owner: ORLANDI, MARK Job Address: 857 NE 97 Street Miami Shores, FL Project: <NONE> Contractor: QUALITY ROOFING CONTRACTORS INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1132060142620 Phone: (305)953 -3333 Building Department Comments ROOF REPAIR TILE ROOF Passed 06(1 1\i Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments 6v February 14, 2012 For Inspections please call: (305)762 -4949 Page 4 of 24 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 :Y JL. I BY: t DEC 21 011 Permit No.0 1 "` 3`il Master Permit No. Permit Type: BUILDING ROOFING Owner's Name (Fee Simple Titleholder) Mark A. Or l and i Phone # (3 0 5) 9 3 4 — 3 7 0 5 Owner's Address 857 N.E. 97 Street City Miami Shores Tenant/Lessee Name Email State F1 Zip 331 38 Phone # Job Address (where the work is being done) 8 5 7 N: E. 9 7 Street City Miami Shores Village County Miami -Dade Zip 3 31 3 8 FOLIO / PARCEL # 1 1- 3206 -01 4 -2620 Is Building Historically Designated YES NO x Flood Zone Contractor's Company NameQuality Roofing Contractor Contractor's Address 13 8 0 0 N . W . 1st Avenue City Miami Qualifier Name Phone# (305) 953 -3333 Carlos Arocho State F1 State Certificate or Registration No. RC 0 0 5 8 6 2 7 Contact Phone (3 0 5) 9 5 3 — 3 3 3 3 Zip 331 68 Phone# 786- 367 -2029 Certificate of Competency No. • 0 0 0 017 8 8 9 E -mail qualityroofing88 @yahoo.com Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ 1 , 2 0 0.0 0 Square / Linear Footage Of Work: 1 / 2 sq . Type of Work: ['Addition DAlteration DNew ® Repair/Replace ❑ Demolition Describe Work: Repair leak at west side of chimney on tile roof. ******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *Fees * ** ********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 50 Submittal Fee $ Permit Fee $ / €" CCF $ CO /CC $ Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Bond $ Double Fee $ Violation date: (0 � .2/0 Structural Review. $ Total Fee Now Due $ See Reverse side -+ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address , City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and reins ection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this /IS— day of 19 c- - , 20 b l , by who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: NOTARY PTTRT.T -STA F vLn$mA Fernandez ° Commission #DD930046 Expires: OCT. 10, 2013 BONDED THRU ATLANTIC BONDLNG CO., INC. Signature Contractor The foregoing instrument was acknowledged before me this /5- day of Der - ,201‘, by ear I,o,) 0t 0 , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: i ; 'Y 'UBLIC•STAT Marylou ernandez My Commission Expires Commission #DD930046 Expires: OCT. 10, 2013 BONDED THRU ATLANTIC BOYDING CO., INC. 4edearde4kdesY****, k9rBe 9e**** sY****k 4:, L• 4zntr** kdr, Ydr*, Y: k, Y, koYoYde, F, Y*** B:*k 4r, Y*ar4e .L•*,Y****9r,k9e,k*4e* k9*** koh*** k*k, Y9e***k+ e*Frdr***3e*str**4r**** APPROVED BY 4/V a- Plans Examiner Engineer (Revised 07 /10 /07)(Revised 06/10/2009) Zoning Clerk checked SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFI CONSIDERATIONS CI If R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. _ i 1 Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be ailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior o removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring nits (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can I� b viewed from below. The-owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. 1 Ponding water: The current roof system and/or deck of the building may not drain well and may ca r water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original r ofing system is removed. Pounding conditions should be corrected. S. V Overflow scuppers ( wall outlets): required It is re uired that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in a rda with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure - - bly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be . - efici -;''o consider additional venting which can result in extending the service life of the 4 roo 4 Own eft Signature Date Revised on 7/9/2009 LD /00,0( Contractor Signature Date 11111111MMIPIRMItindliiiiiMMICE111111111111111111111111MIN •1111••••••• 111111•11MEMIIIMMEMIIIIIIIMMINIMMIE MI111•11111111111111101ME111111111MINEM11111111•111 •INNIIIIMEMINE111111•1M1111111MIN•III•ENE 1111111•1111E111111111MPANIIMMEINIIIMINE11111111MEN MIIIIIMIIIMILMEEMMENIZIEW1=3111111•11111 morommoommoreemmummmum. ROOF ASSEWIBUES AND ROOFTOP STRUCTURES Florida tei r (7 T t2P 1 ". ,?:-H Shores Vi!lage Ar2 PR Z. ON INC, DEP I g Code Edit ,.n ii0o)46 D High-Velocity Hurricane Zone Uniform Permit Appliclatio!qprm. • V( H IJ. ET LL RL sacfrann (General information) Master Permit No. Process No. Contractor's Name •ualit Roof in Contractor, Inc. Job Address 857 N.E. 97 STreet 0 Low Slope 0 Asphaltic Shingles ROOF-CATZGORY echanically Fastened Tile 0 Metal Panel/Shingles 0 Prescriptive BUR-RAS 160 ROOF TYPE 0 New Roof 0 Reroofing 0 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) N/A IX ortar/ ' e 0 Wood gle CS Repair 0 Maintenance Steep Sloped Roof Area (SF) 1 /2sq. Total (SF) 1 / 2sq. Section (ROOf PHan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Sactinn D (Stepp Sinppail P nOf SyCtRM) Existing Tile Roof Roof System Manufacturer: Entegra Roof Tile Notice of Acceptance Number: 11- 0414.10 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations: 1: N/A P2: N/A P3: N/A Maximum Design Pressure (From the Product Approval Specific System): N/A Deck Type: wood 1 X 6 Type Underlayment: Roof Slope: 12 Ridge Ventilation? N/A Mean Roof Height: 13 301b. Insulation: N/A Fire Barrier: N/A Fastener Type & Spacing: 1 1 /4" R/S nails Adhesive Type: Type 111 asphalt Type Cap Sheet: 901b. Roof Covering: Spanish S White Tile. Type & Size Drip 3 X 3 26 ga. Edge: galv. FLORIDA BUILDING CODE — BUILDING MIAM1•DADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Roof Tile, Inc. 1289 NE 9"' Ave. Okeechobee, FL. 34972 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.nhiamidade.sov /building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Valencia Spanish "S" Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA # 10- 0518.02 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. MIAMWADE COUNTY APPROVED NOA No. 11- 0414.10 Expiration Date: 06/07/16 Approval Date: 05/26/11 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This revises a roofing system using Entegra Valencia Spanish "S" Concrete Roof Tile, as manufactured by Entegra Roof Tile Inc. in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code, for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Valencia Spanish "S" Trim Pieces 1= 18" w = 10' /a" 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Okeechobee, FL. TAS 112 TAS 112 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. MIAMIOADE COUNTY APPROVED 7161 -03 Appendix III 7161 -03 Appendix II P0647 -01 P0402 94-084 94 -083 Product Description High profile, interlocking, one - piece, "S" shaped, concrete roof tile equipped with two nail holes. For mechanical, mortar set or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Naxne/Renort Static Uplift Testing PA 102 & PA 102(A) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Age_ Dec. 1991 Dec. 1991 Aug. 1994 Sept. 1993 May 1994 April 1994 NOA No. 11- 0414.10 Expiration Date: 06/07/16 Approval Date: 05/26/11 Page 2 of 6 The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies The Center for Applied Engineering, Inc. Nutting Engineering Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineering 25- 7183 -4 25- 7214 -3 Letter Dated Aug. 1, 1994 Project No. 307025 Test #MDC -78 13343.1 520111 -3 520191 -2 -1 Calculations Evaluation ' Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations 13343.1 Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Wind Tunnel Testing PA 108 (Nail -On) Wind Driven Rain PA 100 Physical Properties TAS 112' Static Uplift Testing PA 101 Aerodynamic Multiplier 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Restoring Moment Due to Gravity Two Patty Adhesive Set System Physical Properties TAS 112 Feb. 1995 March, 1995 Aug. 1994 Oct. 1994 June 2007 Dec. 1998 March 1999 Oct 2007 February 1996 April 1996 December 1996 March 1995 August 2007 April 1999 March 2009 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building and Neighborhood Compliance Department — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No. 11-0414.10 Expiration Date: 06 /01/16 Approval Date: 05/26/11 Page 3 of 6 4. INSTALLATION 4.1 Entegra Valencia Spanish "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (Ibf) Length -I (ft) Width -w (ft) Valencia Spanish "S" Tile 11.1 1.5 .854 Table 3: Restoring Moments due to Gravity - Ma (ft-Ibf) Table 2: Aerodynamic Multipliers - X (ft3) 3 ":12" Tile 5 ":12" A. (ft3) Greater than .7 ":12" ? (ft) Profile Direct Deck Batten Application Direct Deck Application Valencia Spanish "S" Tile Direct Deck 0.232 0252 Table 3: Restoring Moments due to Gravity - Ma (ft-Ibf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" Greater than .7 ":12" Valencia Spanish "S" Tile Bette ns Direct Deck Battens Direct Deck Battens Direct Deck Batten s Direct Deck Batten s Direct Deck 6.70 7.10 6.60 7.00 6.46 6.84 6.30 6.67 4.08 6.48 Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19132" plywood) Battens Valencia Spanish "S" Tile 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail' 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw' 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1 -10d Smooth or Screw Shank Nail (Field Clip)° 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail (Eave Clip)' 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 1 When using only one fastener use the hole that is approximately 44/4" away from interlocking edge MIAMbDADE APPROVED NOA No. 11-0414.10 Expiration Date: 06/07/16 Approval Date: 05/26/11 Page4of6 Table 5: Attachment Resistance Expressed as a Moment Mr (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Valencia Spanish "S" Tile Adhesive 29.34 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - M1 (ft -Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Valencia Spanish "S» Tile Polyfoam PoIyProTM 68.5" Polyfoam PolyProTM 38.7" 4 Large paddy placement of 45 grams of PolyProTM. 5 Medium paddy placement of 24 grams of PolyProT". Table 7: Attachment Resistance Expressed as a Moment - Mr(ft-Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Valencia Spanish "S" Tile Mortar Set 24.5 5. LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". ENTEGRA VALENCIA SPANISH 4S' TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. 'MAMI.DADE coUNTY APPROVED NOA No. 11- 0414.10 Expiration Date: 06/07/16 Approval Date: 05/26/11 Page 5 of 6 PROFILE DRAWING ENTEGRA VALENCIA SPANISH "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE M IDADECOUNTY APPROVED NOA No. 11-0414.10 Expiration Date: 06/07/16 Approval Date: 05/26/11 Page 6 of 6