Loading...
MC-11-513Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 157505 Permit Number: MC -3 -11 -513 Scheduled Inspection Date: April 02, 2012 Inspector: Perez, JanPierre Owner: Job Address: 9475 NE 2 Avenue Miami Shores, FL 33138- Project: <NONE> Contractor: HARPERS AIR, INC. Permit Type: Mechanical - Commercial Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132060133760 Phone: 305 - 266 -1040 Building Department Comments AC REPLACEMENT AND REPAIRS 2 UNIT REPLACEMENT 40 TON AND 10 TON Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. April 02, 2012 For Inspections please call: (305)762-4949 Page 1 of 39 ai2-4111 1\\Ascict 9kli - t-AL(W-f 1-11121 i -Nett faV i� i6s Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 ggS MAR 232011 Permit No. C ` I Master Permit No. Permit Type: MECHANICAL OWNER: Name (Fee Simple Titleholder): Bank of America Phone# 9049874716 Address: 9000 Southside Blvd., Bldg 300 1st Floor City: Jacksonville State: FL zip: 32256 Tenant/Lessee Name: Phone#: Email: sheny.andersongcbre.com JOB ADDRESS: 9499 NE 2nd Avenue City: Miami Shores County: Miami Dade Zip: 33138 FoliolParcel #: 11- 3206 -013 -3760 Is the Building Historically Designated: Yes NO x Flood Zone: CONTRACTOR: Company Name: Harper's Air, Inc. Address: 1031 SW 69 Ave Phone#:305- 266-1040 City: Miami State: FL Zip: 33144 Qualifier Name: 17:e. \ \ \ . H co' pcx phone: \� 0 S � (P -164 0 State Certification or Registration #: C AC 0 a-3 "f - -- Contact Phone#: Email Address: DESIGNER: Architect/Engineer Architectural Design Collaborative 4°0 Value of Work for this Permit $ 990 • Square/Linear Footage of Certificate of Competency #: \-c P 50.ar� CLAD \ . CC ) Phone#: 407-629 -1188 Type of Work: °Address °Alteration Description of Work: A/C replacement and repairs °New ork: 20,067 bldg sf °Repair/Replace °Demolition ********* ** * * * * * * * * * * * * * * * ***** * * * * *** *F ** ray+ * *************It******************* Submittal Fee $ ■ J... -.9 Permit Fee $ , l � �/ t V F $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ PERMIT # M C (l - 1 CONTRACTOR: CI 4145 NEI SUBMITTAL DATE: r ot 9,3 J 1 ADDRESS: q fly 1..4_ a piv NAME:° 4:1111b21CA- RESUBMITAL DATES: PROJECT TYPE: ZONING FIRE STRUCTURAL IMPACT FEES ELECTRICAL HRS/DERM A- PLUMBING NOC MECHANICAL MECHANICAL 411 '"p BLD �� ■ a V, '\ Bonding Company's Name (if applicable) Bonding Company's Address City Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice; the inspection will not be approved and a rei ection fee will be charged Signature Owner or Agent The foregoing instrument was acknowledged before me this f The foregoing instrument was acknowledged before me this day of iftVaeth 20 IL, by _da f LYI , day of , 20 /L by /eler ,4"1-- Signature -7-e7 /4- Contractor who is persona known to me or who has produced As identification and who did take . o NOTARY PUBLIC: Sign: Print: who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: a�P" Pe, Notary Public State of Florida Nicole Glass rl My Commission EE032587 'lira", Expires 10 /05/2014 My Commission Expires: /0/0151Li * * * * * * * * * * * * * * ** * * * * * * * ** APPROVED BY Sign: Print My Commission Expires: 2//27/219/02 Plans Examiner Zoning Structural Review (Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09) Clerk 04/29/2011 08:22 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES el ow. * * * * * * * * * * * * * * * * * * * ** * ** TX REPORT * ** * * * * * * * * * * * * * * * * * * * ** TRANSMISSION OK TX /RX NO 1320 RECIPIENT ADDRESS 93052622219 DESTINATION ID ST. TIME 04/29 08:22 TIME USE 00'43 PAGES SENT 1 RESULT OK Permit No: 11 -513 Job Name: April 27, 2011 Miami Shores Viiiage Building Department Building Critique Sheet 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 1) Plans must be approved by Miami dade DERM. 2) Provide a permit application from a licensed contractor. Providing a license is not a permit application. 3) The licensed roofing contractor must submit a high velocity uniform roofing application. The instructions for that require product approvals for all components. Complete all sections that apply. 4) The contract submitted includes ceiling and drywall work. A permit for this will also be required. Provide a floor plan identifying areas to be altered/ repaired with a complete scope of work. Review STOPPED Plan review is not complete, when all items above are corrected, we will dos complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 �n� : 'mss- APR 062011 ` FIARPER'S AIR, INC. Certified Air Conditioning Contractors Sales & Services • CACO23492 PROPOSAL TO: Southeast Construction Attn: Rabih Boueri Job: BOA Miami Shores 9499 NE 2nd Ave DATE: January 22, 2011 We hereby propose to furnish and install: - (1) 65 ton Chiller with pumps and required valves.(1) 40 ton air handling unit. - (1) 10 ton Rooftop package unit, (1) 10 ton split system. - (8) Vav boxes(2) with heat, (6) Duct heaters. - Controls as per plans. Supply and return chill water piping in copper with Pro Press fittings insulated with 1 1/2" foam glass as per plans. - Demo existing systems to be replaced and ductwork as shown on plans. - New Supply and return ductwork with grills for 11 floor as per plans. - Test and balance of ls` floor ductwork. - Programming , start up and owner training of system. TOTAL MATERIAL AND LABOR $ 326,500.00 Not included Structural Steel supports on roof Any alarm integration Stew Sirnm Note: This proposal may be withdrawn if not accepted within 30 days. ACCEPTANCE OF PROPOSAL - The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. DATE: `�' %/ SIGNATURE:_ 1031 Southwest 69th Avenue • Miami, Florida 33144 • (305) 266 -1040 FAX (305)262 -2219 WIPARWEW 001. Ttrestone BUILDING PRODUCTS APP 160 Meets ASTM D 6222, Type I, Grade S Tested in Accordance with D 5147 Firestone Item Number: W70APP0162 DESCRIPTION: Firestone APP 160 is a smooth surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade S. APP 160 is ideal for both new construction and re- roofing applications as a base ply, cap sheet, or as a flashing sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 160 application. APPLICATION METHOD: APP 160 shall be installed by fully heat welding the membrane to an appropriate substrate. STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. This sheet is meant to highlight Firestone's products and specifications and Is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no (lability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. gal ®`N SH; Mineral Release Agent 0212:1 °(2011 °' Glass Reinforced Polyester Mat APP Modified Bitumen Burn -off Film an fac t, od., i a ISO 900, fee Q stew.>, ed Fac PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 3.3 ft (1 m) 32'10" (10 m) 98 sq ft (9.1 sq m) 98 Ib (44.5 kg) 48" x 39" (1.1 m x 1 m) 20 2,020 Ib (918 kg) 26 Stack Firestone APP 160 Squarely In Original Unopened Packaging No More Than Two (2) Pallets High, PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 8% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN APPROVED a,Ro,,eo Firestone Building Products Company, LLC 250 West 96"' Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -020 1 APP 160 Meets ASTM D 6222, Type I, Grade S Tested in Accordance with D 5147 MAT Firestone BUILDING PRODUCTS 2/21120 Dimensions and Mass English Metric Pro a p rty Unit ASTM Minimum Firestone Typical Unit ASTM Minimum Firestone Typical Product Thickness mil 140 160 mm 3.5 3.8 Net Mass lb/100 ft2 70 100 g /m2 3,417 4,003 Bottom Coating mil 30 50 mm 0.8 1.3 hysical Properties Peak Load at 0 °F ( -18 °C) (Tensile Strength) Ibf /in 60 MD 169 kN /m 14.0 MD 30 XMD 137 XMD 24 Elongation at Peak Load at MD 52 MD 52 0 °F ( -18 °C) o /0 10 XMD 39 % /0 10 XMD 39 Peak Load at 73.4 °F (25 °C) (Tensile Strength) Ibf /in 50 MD 75 kN /m 8.8 MD 16 XMD 58 XMD 14 Elongation at Peak Load at MD 48 o MD 48 73.4 °F (25 °C) /0 23 XMD 52 /0 23 XMD 52 Ultimate Elongation (at 5% of MD 57 MD 57 Peak Load) at 73.4 °F (25 °C) % 30 XMD 60 % 30 XMD 60 Tear Strength at 73.4 °F (25 °C) Ibf 70 MD 122 N 311.5 MD 543 XMD 91 XMD 405 MD -0.07 % MD -0.07 Dimensional Stability Change 1 Change 1 XMD 0.3 XMD 0.3 Low Temperature Flexibility °F 32 14 °C 0 -10 High Temperature Stability °F 230 270 °C 110 132 Phsical Pro After Heat Conditionin y p Peak Load at 73.4 °F (25 °C) lbf/in 50 MD 90 kN /m 8.8 MD 16 (Tensile Strength) XMD 62 XMD 11 Elongation at Peak Load at % MD 43 % MD 43 /0 73.4 °F (25 °C) 23 XMD 38 /0 23 XMD 38 Low Temperature Flexibility °F 32 10.0 °C 0 -12.2 S723 -RFS -020 S723 -RFS -020 ECH NH AFT L I H°ORMATIO SHEIE. '1303 09/29/2009 Virestonc BUILDING PRODUCTS Pourable Sealer S -10 Parts A & B Firestone Item Number: W563587065 DESCRIPTION: Pourable Sealer S -10 is designed for sealing penetration pockets used in conjunction with Firestone roof systems. METHOD OF APPLICATION: 1. Substrates must be free from water, dust, dirt, oil, and other contaminants. 2. After preparation of the penetration pocket per Firestone Details, pour Part B into Part A and mix thoroughly using a drill with a mixing blade. Mix until the Part A material is uniform in color. If material contains gray streaks, mixing should continue. Mix so that material on the bottom and sides of the can is fully circulated and blended. 3. Pour the Pourable Sealer into the penetration pocket. Fill penetration pocket so that water is shed from the actual penetration. 4. Do not thin Pourable Sealer or use partial quantities. COVERAGE RATE: Coverage rate of 200 cu. in (3277 cu. cm) for each mixture of Part A and Part B can be expected. PHYSICAL PROPERTIES: Property Typical Performance Base: Polyurethane Color: Mixed: Black Part A: Light Gray Part B: Black None 100% Part A: 250,000 - 325,000 cps w /Brookfield #7 spindle@ 4 RPM Part B: Thin, Free Flowing Part A: 1.25 Part B: 1.14 Part A: 10.40 lb/gal (1.25 kg /L) Part B: 9.50 lb/gal (1.14 kg /L) 1 can of Part B to 1 can of Part A 30 minutes (max.) at 72 °F (22.22 °C) 0 g/L Solvents: Solids: Viscosity: Specified Gravity: Weight/Gallon: Mix Ratio: Pot Life V.O.C. Content: This sheet Is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to property support a planned Installation is In question. No Firestone representative is authorized to vary this disclaimer. POURABLE f SEALER 3-10 Min .30 Jai WWI orr was "Yu r«. SEAM' u -il? PAS' A L; n- t:5-.: Si PACKAGING: • Part A: One gallon (3.78 L) can • Part B: One pint (.47 L) can • Carton: 4 one - gallon cans and 4 one -pint cans • Carton weight: about 46 lb (21 kg) SHELF LIFE: • Shelf life of one year can be expected when stored in original sealed containers at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C). • Shelf life will be shortened if exposed to elevated temperatures. STORAGE: • Store in original unopened containers, at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C) until ready for use. • When exposed to lower temperatures, restore to room temperature prior to use. • For optimum results, rotate stock to ensure stored material has not exceeded the shelf life of one year. PRECAUTIONARY DATA: • Review Material Safety Data Sheet prior to use. • Avoid moisture contamination. Contact with water can generate explosive pressure in a closed container. • Thinning is not allowed. • Do not contaminate with foreign materials. • Avoid contact with skin. Pourable Sealer is extremely difficult to remove. Disposable gloves are recommended when mixing and dispensing Pourable Sealer. • Avoid breathing vapors. Use only in well ventilated areas. • Cover containers tightly when not in use. LEED INFORMATION: Post Consumer Recycled Content: Post Industrial Recycled Content: Manufacturing Location: 0% 0% South Bend, IN Firestone Building Products Company 250 W. 9&" Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -110 Firestone BUILDING PRODUCTS APP 180 FR Meets ASTM D 6222, Type I, Grade G Tested in Accordance with ASTM D 5147 Firestone Item Number: W7OPUWP180F (UltraWhiterm) W7OPWP180F (White) W7OPBP180F (Black) DESCRIPTION: Firestone APP 180 FR is a granule - surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade G. APP 180 FR is ideal for both new construction and re- roofing applications as a cap sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 180 FR application. . Firestone APP 180 FR with UltraWhite granules has a highly reflective surface designed to meet national, state and local energy code requirements. UIti Solar Reflectance Index (SRI) = 89 SRI calculated using the ORNL (DOE) calculator, ASTM E 1980 -01 UltraWhite granules can help achieve points in the U.S. Green Building Council's LEED® rating system and meet the requirements for California's Title 24 regulations. APPLICATION METHOD: APP 180 FR shall be installed by fully heat welding to an appropriate substrate. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor Its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation If the structural soundness or structural ability to properly support a planned installation is In question. No Firestone representative is authorized to vary this disclaimer. Granule Surfacing APP FR Modified Bitumen Glass Reinforced Polyester Mat antufactured in an ISO 9001 Re • istered Facilit STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live Toad of the storage area. PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 39.4" (1 m) 32' 10" (10 m) 98 sq. ft (9.1 sq. m) 107 lb (46.5 kg) 48 "x 39" (1.2 m x 1 m) 20 2,108 (958 kg) 21 Stack Firestone SBS Premium FR Sauarelv In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 6% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN t.1!"l -'% ROVED Note: Note: Dade County Approval of UltraWhite products Is pending Firestone Building Products Company, LLC 250 West 96s' Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -028 )nitla( Weathered Solar Reflectance 0.72 Pending Thermal Emittance 0.90 Pending CR C Rated Product ID 0029 Licensed Manufacturer ID 0608 `” ro en u'e tac.., on haze. Classification Production Une Cool Roof Rating Council ratings are determined for a fixed set of conditions, and may not be appropriate for determining seasonal energy performance. The actual effect of solar reflectance and thermal eminence on building performance may vary. Manufacturer of product stipulates that these ratings were determined in accordance with the appflcable Cool Roof Rating Council procedures. Solar Reflectance Index (SRI) = 89 SRI calculated using the ORNL (DOE) calculator, ASTM E 1980 -01 UltraWhite granules can help achieve points in the U.S. Green Building Council's LEED® rating system and meet the requirements for California's Title 24 regulations. APPLICATION METHOD: APP 180 FR shall be installed by fully heat welding to an appropriate substrate. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor Its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation If the structural soundness or structural ability to properly support a planned installation is In question. No Firestone representative is authorized to vary this disclaimer. Granule Surfacing APP FR Modified Bitumen Glass Reinforced Polyester Mat antufactured in an ISO 9001 Re • istered Facilit STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live Toad of the storage area. PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 39.4" (1 m) 32' 10" (10 m) 98 sq. ft (9.1 sq. m) 107 lb (46.5 kg) 48 "x 39" (1.2 m x 1 m) 20 2,108 (958 kg) 21 Stack Firestone SBS Premium FR Sauarelv In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 6% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN t.1!"l -'% ROVED Note: Note: Dade County Approval of UltraWhite products Is pending Firestone Building Products Company, LLC 250 West 96s' Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -028 APP 180 FR Meets ASTM D 6222, Type I, Grade G Tested in Accordance with ASTM D 5147 409 2/22/2011'1 'Firestone BUILDING PRODUCTS Dimensions and Mass English Metric Property p rty Unit ASTM Minimum Firestone Nominal Una ASTM Minimum Firestone Nominal Product Thickness mil 160 162 mm 4.1 4.1 Net Mass lb /100 ft2 85 109 g /m2 4,149 5,320 Bottom Coating mil 30 43 mm 0.8 1.1 Physical Properties Peak Load at 0 °F ( -18 °C) (Tensile Strength) Ibf /in 60 MD 120 kN /m 10.5 MD 21 XMD 98 XMD 17 Elongation at Peak Load at 0 °F ( -18 °C) ° /0 10 MD 27 ° /0 10 MD 27 XMD 25 XMD 25 Peak Load at 73.4 °F (25 °C) (Tensile Strength) lbf/in 50 MD 79 kN /m 8.8 MD 14 XMD 64 XMD 11 Elongation at Peak Load at 73.4 °F (25 °C) /0 % 23 MD 39 ° /O 23 MD 39 XMD 50 XMD 50 Ultimate Elongation (at 5% of Peak Load) at 73.4 °F (25 °C) % 30 MD 46 % 30 MD 46 XMD 55 XMD 55 Tear Strength at 73.4 °F (25 °C) Ibf 70 MD 119 N 311 MD 530 XMD 86 XMD 382 Dimensional Stability % Change 1 MD -0.05 % Change 1 MD -0.05 XMD 0.06 XMD 0.06 Low Temperature Flexibility °F 32 14 °C 0 -12 High Temperature Stability °F 230 270 °C 110 132 Granule Loss g 2 0.6 v Peak Load at 73.4 °F (25 °C) (Tensile Strength) lbf/in 50 MD 70 kN /m 8.8 MD 12 XMD 59 XMD 12 Elongation at Peak Load at MD 40 ° MD 40 73.4 °F (25 °C) o /0 23 XMD 47 /O 23 XMD 47 Low Temperature Flexibility °F 32 9 0 °C 0 -12.8 S723 -RFS -028 SOUTHEAST GENERAL CONSTRUCTION, INC. 120 N. SWINTON AVENUE • DELRAY BEACH, FL 33444 • PHONE (561) 278 -2776 • FAX (561) 278 -2771 PROJECT: BANK OF AMERICA — MIAMI SHORES 9499 NE 2 °d AVE, MIAMI SHORES, FL DATE: 05/26/11 Page 1 of 1 Ref: Bldg Dept response City of Miami Shores Building Department Miami Shores, FL To whom it may concern: The purpose of this letter is to address your comments regarding the above referenced project. Please find attached the following items as requested: • Copy of revised Contract • Roofing contractor's application and licensing information • Submittal of products used to repair new roof penetrations for A/C stands and electrical/mechanical pipes. • FBC 2007 High Velocity Hurricane Zone Uniform Permit Application We hope the review comments are addressed to your satisfaction. Should any section require further detail please feel free to contact our office. Sincerely yours, pilli Southeast General Construction, Inc CGC #055026 Ph (561) 278 -2776 Fax (561) 278 -2771 1 CBRE CO RICHARD ELLIS Work Authorization Master Contract No. LSPSEGEN20120101.0.0 CBRE Real Estate Services, Inc. hereby authorizes the Work and /or Services described hereunder pursuant and in accordance with the terms and conditions of the Master Services Agreement / Contract referenced above. " " ""° " " "" THIS FORM 18 NOT VALID WITHOUT A WORK AUTHORIZATION NUMBER "". ►"s"rsr. Project Name: Miami Shores /Shores Villages - HVAC CBRE Work Authorization #: FL.0238.10 -006- RC1100757 Issue Date: 4/20/2011 CBRE Project Number. FL0238.10 Supplier Name: Southeast General Construction, CBRE Project Manager: Mike Kaplan Supplier Contact: Rabih Boueri PjM Manager Tel & Fax: 73 -7055 CW Job Number. RCI100757 Sr. Management. Contact Michael Morabito Estimated Due Date: 6/15/11 BAC Facility Location Name: Miami Shores Project Type: RB= Retail BAU Address: 9499 Northeast 2nd Ave. Project Architect ADC City/State/Zip: Miami Shores / FL / 33138 1. Scope of Work: The scope of work shall include but not be limited to the knowing: Remove existing air conditioning equipment including disconnect switches, piping and insulation, sheet metal connections, wiring, etc. and install new equipment, disconnect switches, piping and insulation and power and control wiring and reconnect to iC3 system where required. Provide start up, commissioning and testing and balancing services and a Test and balance Report. Provide labor and materials to deliver, lift and install all equipment. Remove ail old equipment and debris. Ail work is to be performed after regular banking hours and on weekends or in phases so as not to interfere banking center operations. All terms are in accordance with your Master Agreement and Schedule of Values. 2. Exhibits or File Attachments: Please list all drawing(s), plans, specifications, addenda or other documents applicable to this Work Authorization: 3. instructions: In accordance with your contract for the Project fisted above: a. Please provide Consulting Services based on the Hourly Rates Exhibit, not — exceed: — b. Please prepare a Budget Proposal Form (BPF) or Schedule of Values (SOV) X c. Please begin execution of the Scope of Work for the Project listed above (BPF to $tCauif'of S®rolcesl, for the above Scope of Work /SOV /Proposal attached) 4. Pricing: Supplier warrants and covenants to provide the Work and Services for the Price listed below: Contractor Work $591,1$1.54 Authorization : CBRE Project Manager. 5. CBRE Authorization: 6. Supplier Acceptance: This form must be p y signed both Con -,.. and the CBRE peisormel the appropriate signing authority. J ` %i ti " Date Tide /1 Pty% ?-- 43 J/ j� Q to S/i `l�/ I•J. l Name Date 1 hereby aotmowledge receipt and accept the commission of the Services and/or Work as stated herein for the Price listed above. The signatory represents they are a duly authorized representative of the Contractor with contractual authority to bind Contractor with respect to the Services and the Work described herein. 7. Dates: . Please define the Commencement Date, Date of Substantial Completion and Date of Final Completion: Commencement Date: Date of Substantial Completion: Date of Foal Completion: 4120/2011 6/15/2011 6/15/2011 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 ' Fax: (305) 756.8972 Permit No. V y 13 Job Name Date MECHANICAL CRITIQUE SHEET v�e.ak, Carty 0• � PERMIT #: 1, <avv-y Contractor ❑ Owner ❑ Architect Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT Picked up 2 sets of plans and (other) Address: , From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: — PERMIT CLERK INITIAL: RESUBMITTED DATE: PERMIT CLERK INITIAL: V" 1 04/01/2011 08:32 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES I7j001 $$$ TX REPORT * ** TRANSMISSION OK TX /R% NO 1233 RECIPIENT ADDRESS 9044191004 DESTINATION ID ST. TIME 04/01 08:31 TIME USE 00'42 PAGES SENT 2 RESULT OK Permit No: 11 -513 Job Name: April 27, 2011 Miami Shores Village Building Department Building Critique Sheet 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 1) Plans must be approved by Miami dade DERM. 2) Provide a permit application from a licensed contractor. Providing a license is not a permit application. 3) The licensed roofing contractor must submit a high velocity uniform roofing application. The instructions for that require product approvals for all components. Complete all sections that apply. 4) The contract submitted includes ceiling and drywall work. A permit for this will also be required. Provide a floor plan identifying areas to be altered/ repaired with a complete scope of work. Review STOPPED Plan review is not complete, when all items above are corrected, we will doa complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 FA->( ((g- PeQ\i9 qu-t— vaal Permit No: 11 -S17' Job Name , 2011 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 �•� Building Crittiique Sheet c /4L 'c(G I,3 e seer A Dot �o rt. �• 4'-z -� y4e‘ - Q a'o� ts-2'1"ll )Z1 ct0-1 - - 10°4 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 03/24/2011 08:39 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES al001 * * * * * * * * * * * * * * * * * * * ** * ** TX REPORT * ** * * * * * * * * * * * * * * * * * * * ** TRANSMISSION OK TX /RX NO 1208 RECIPIENT ADDRESS 915612782771 DESTINATION ID ST. TIME 03/24 08:39 TIME USE 00'24 PAGES SENT 2 RESULT OK Permit No: i i- 7y Job Name , 2011 Miami Shores Vmage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Building Critique Sheet` A Page 1 of 1 0 2. • Z"1 `l HARPER'S AIR, INC. Certified Air Conditioning Contractors Sales & Services • CACO23492 PROPOSAL TO: Southeast Construction Attn: Rabih Boueri Job: BOA Miami Shores 9499 NE 2°a Ave DATE: January 22, 2011 We hereby propose to furnish and install: - (1) 65 ton Chiller with pumps and required valves.(1) 40 ton air handling unit. - (1) 10 ton Rooftop package unit, (1) 10 ton split system. - (8) Vav boxes(2) with heat, (6) Duct heaters. - Controls as per plans. Supply and return chill water piping in copper with Pro Press fittings insulated with 11h" foam glass as per plans. - Demo existing systems to be replaced and ductwork as shown on plans. - New Supply and return ductwork with grills for 1st floor as per plans. - Test and balance of 1'` floor ductwork. - Programming , start up and owner training of system. TOTAL MATERIAL AND LABOR $ 326,500.00 Not included Structural Steel supports on roof Any alarm integration c Simm Note: This proposal may be withdrawn if not accepted within 30 days. ACCEPTANCE OF PROPOSAL - The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. DATE: `�° l ll SIGNATURE: —� 1031 Southwest 69th Avenue • Miarni, Florida 33144 • (305) 266 -1040 FAX (305)262 -2219 ORMATI 'Firestone BUILDING PRODUCTS APP 160 Meets ASTM D 6222, Type I, Grade S Tested in Accordance with D 5147 Firestone Item Number: W70APP0162 DESCRIPTION: Firestone APP 160 is a smooth surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade S. APP 160 is ideal for both new construction and re- roofing applications as a base ply, cap sheet, or as a flashing sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 160 application. APPLICATION METHOD: APP 160 shall be installed by fully heat welding the membrane to an appropriate substrate. STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a Tight colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to Installation if the structural soundness or structural ability to properly support a planned Installation Is in question. No Firestone representative is authorized to vary this disclaimer. Mineral Release Agent Glass Reinforced Polyester Mat APP Modified Bitumen Bum -off Film lane fact rred in an IS`O 900 `istered Fa ili'te PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 3.3 ft (1 m) 32' 10" (10 m) 98 sq ft (9.1 sq m) 98 Ib (44.5 kg) 48" x 39" (1.1 m x 1 m) 20 2,020 Ib (918 kg) 26 Stack Firestone APP 160 Squarely In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 8% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN APPROVED 1APPROVED[ Firestone Building Products Company, LLC 250 West 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -020 APP 160 Meets ASTM D 6222,: Type 1, Grade S Tested in Accordance with D 5147 F'O` . MATIO1 'Firestone BUILDING PRODUCTS 21/2011F Dimensions and Mass English Metric Property p rty Unit ASTM Minimum Firestone Typical Unit ASTM Minimum Firestone Typical Product Thickness mil 140 160 mm 3.5 3.8 Net Mass lb/100 ft2 70 100 g /m2 3,417 4,003 Bottom Coating mil 30 50 mm 0.8 1.3 Physical Properties Peak Load at 0 °F ( -18 °C) (Tensile Strength) Ibf /in 60 MD 169 kN /m 14.0 MD 30 XMD 137 XMD 24 Elongation at Peak Load at MD 52 o MD 52 0 °F ( -18 °C) o /0 10 XMD 39 /0 10 XMD 39 Peak Load at 73.4 °F (25 °C) °F 32 MD 75 0 -12.2 MD 16 (Tensile Strength) Ibf /in 50 XMD 58 kN /m g 8 XMD 14 Elongation at Peak Load at MD 48 o MD 48 73.4 °F (25 °C) o /0 23 XMD 52 /0 23 XMD 52 Ultimate Elongation (at 5% of MD 57 MD 57 Peak Load) at 73.4 °F (25 °C) % 30 XMD 60 % 30 XMD 60 Tear Strength at 73.4 °F (25 °C) lbf 70 MD 122 N 311.5 MD 543 XMD 91 XMD 405 MD -0.07 % MD -0.07 Dimensional Stability Change 1 XMD 0.3 Change 1 XMD 0.3 Low Temperature Flexibility °F 32 14 °C 0 -10 High Temperature Stability °F 230 270 °C 110 132 Heat Conditionin Peak Load at 73.4 °F (25 °C) (Tensile Strength) lbf/in 50 MD 90 kN /m 8.8 MD 16 XMD 62 XMD 11 Elongation at Peak Load at MD 43 o MD 43 73.4 °F (25 °C) o /0 23 XMD 38 /0 23 XMD 38 Low Temperature Flexibility °F 32 10.0 °C 0 -12.2 S723 -RFS -020 N CAL INFORMATION SH EI 'Firestone BUILDING PRODUCTS Pourable Sealer S -10 PartsA &B Firestone Item Number: W563587065 DESCRIPTION: Pourable Sealer S -10 is designed for sealing penetration pockets used in conjunction with Firestone roof systems. METHOD OF APPLICATION: 1. Substrates must be free from water, dust, dirt, oil, and other contaminants. 2. After preparation of the penetration pocket per Firestone Details, pour Part B into Part A and mix thoroughly using a drill with a mixing blade. Mix until the Part A material is uniform in color. If material contains gray streaks, mixing should continue. Mix so that material on the bottom and sides of the can is fully circulated and blended. 3. Pour the Pourable Sealer into the penetration pocket. Fill penetration pocket so that water is shed from the actual penetration. 4. Do not thin Pourable Sealer or use partial quantities. COVERAGE RATE: Coverage rate of 200 cu. in (3277 cu. cm) for each mixture of Part A and Part B can be expected. PHYSICAL PROPERTIES: Proof Proof& Typical Performance Base: Polyurethane Color: Mixed: Black Part A: Light Gray Part B: Black None 100% Part A: 250,000 - 325,000 cps w /Brookfield #7 spindle@ 4 RPM Part B: Thin, Free Flowing Part A: 1.25 Part B: 1.14 Part A: 10.40 lb/gal (1.25 kg/L) Part B: 9.50 lb/gal (1.14 kg /L) 1 can of Part B to 1 can of Part A 30 minutes (max.) at 72 °F (22.22 °C) 0 g/L Solvents: Solids: Viscosity: Specified Gravity: Weight/Gallon: Mix Ratio: Pot Life V.O.C. Content: This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. nutu61.E sEAtzti eanrn �:.. PACKAGING: • Part A: One gallon (3.78 L) can • Part B: One pint (.47 L) can • Carton: 4 one - gallon cans and 4 one -pint cans • Carton weight: about 46 lb (21 kg) SHELF LIFE: • Shelf life of one year can be expected when stored in original sealed containers at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C). • Shelf life will be shortened if exposed to elevated temperatures. STORAGE: • Store in original unopened containers, at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C) until ready for use. • When exposed to lower temperatures, restore to room temperature prior to use. • For optimum results, rotate stock to ensure stored material has not exceeded the shelf life of one year. PRECAUTIONARY DATA: • Review Material Safety Data Sheet prior to use. • Avoid moisture contamination. Contact with water can generate explosive pressure in a closed container. • Thinning is not allowed. • Do not contaminate with foreign materials. • Avoid contact with skin. Pourable Sealer is extremely difficult to remove. Disposable gloves are recommended when mixing and dispensing Pourable Sealer. • Avoid breathing vapors. Use only in well ventilated areas. • Cover containers tightly when not in use. LEED INFORMATION: Post Consumer Recycled Content: Post Industrial Recycled Content: Manufacturing Location: 0% 0% South Bend, IN Firestone Building Products Company 250 W. 96"' Street, Indianapolis, IN 46260 Sales: (800) 428-4442 • Technical (800) 428.4511 www.firestonebpco.com S723 -RFS -110 'Firestone BUILDING PRODUCTS APP 180 FR Meets ASTM D 6222, Type 1, Grade G Tested in Accordance with ASTM D 5147 Firestone Item Number: W7OPUWP180F (UltraWhiteTv") W7OPWP180F (White) W7OPBP180F (Black) DESCRIPTION: Firestone APP 180 FR is a granule - surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade G. APP 180 FR is ideal for both new construction and re- roofing applications as a cap sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 180 FR application. . Firestone APP 180 FR with UltraWhite granules has a highly reflective surface designed to meet national, state and local energy code requirements. Solar Reflectance Index (SRI) = 89 SRI calculated using the ORNL (DOE) calculator, ASTM E 1980 -01 UltraWhite granules can help achieve points in the U.S. Green Building Council's LEED® rating system and meet the requirements for California's Title 24 regulations. APPLICATION METHOD: APP 180 FR shall be installed by fully heat welding to an appropriate substrate. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for fumishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned Installation is in question. No Firestone representative is authorized to vary this disclaimer. Glass Reinforced Polyester Mat APP FR Modified Bitumen Burn -off Film o an afactu e ngS® 9Q jR 4 giste'peld,Fa,.c; ll(t. f STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 39.4" (1 m) 32'10" (10 m) 98 sq. ft (9.1 sq. m) 107 lb (46.5 kg) 48"x 39" (1.2 m x 1 m) 20 2,108 (958 kg) 21 Stack Firestone SBS Premium FR Squarely In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. • This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. • Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 6% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN APPROVED I, Note: Dade County Approval of UltraWhite products is pending ysrestone Firestone Building Products Company, LLC 250 West 96s' Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -028 initial weatherer! Solar Reflectance 0.72 Pending Thermal Emittance 0.90 Pending Rated Product ID 0029 Licensed Manufacturer ID 0608 caen k, v, (ait .t. Ka LI Classification Production Line Cool Roof Rating Council ratings are determined for a fixed set of conditions, and may not be appropriate for determining seasonal energy performance. The actual effect of solar reflectance and thermal emittance on building performance may vary. Manufacturer of product stipulates that these ratings were determined In accordance with the applicable Cool Roof Rating Council procedures. Solar Reflectance Index (SRI) = 89 SRI calculated using the ORNL (DOE) calculator, ASTM E 1980 -01 UltraWhite granules can help achieve points in the U.S. Green Building Council's LEED® rating system and meet the requirements for California's Title 24 regulations. APPLICATION METHOD: APP 180 FR shall be installed by fully heat welding to an appropriate substrate. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for fumishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned Installation is in question. No Firestone representative is authorized to vary this disclaimer. Glass Reinforced Polyester Mat APP FR Modified Bitumen Burn -off Film o an afactu e ngS® 9Q jR 4 giste'peld,Fa,.c; ll(t. f STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 39.4" (1 m) 32'10" (10 m) 98 sq. ft (9.1 sq. m) 107 lb (46.5 kg) 48"x 39" (1.2 m x 1 m) 20 2,108 (958 kg) 21 Stack Firestone SBS Premium FR Squarely In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. • This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. • Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 6% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN APPROVED I, Note: Dade County Approval of UltraWhite products is pending ysrestone Firestone Building Products Company, LLC 250 West 96s' Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -028 APP 180 FR Meets ASTM D 6222, Type 1, Grade G Tested in Accordance with ASTM D 5147 409 2122/2011, 'Firestone BUILDING PRODUCTS Dimensions and Mass E English M Metric Property U Unit A ASTM F Firestone U Unit A ASTM F Firestone Product Thickness m mil 1 160 1 162 m mm 4 4.1 4 4.1 Net Mass l lb/100 ft2 8 85 1 109 g g /m2 4 4,149 5 5,320 Bottom Coating m mil 3 30 4 43 m mm 0 0.8 1 1.1 Physical Properties Peak Load at 0 °F ( -18 °C) (Tensile Strength) Ibf /in 60 MD 120 kN /m 10.5 MD 21 XMD 98 XMD 17 Elongation at Peak Load at MD 27 ° MD 27 0 °F ( -18 °C) ° /° 10 XMD 25 /O 10 XMD 25 Peak Load at 73.4 °F (25 °C) MD 79 MD 14 (Tensile Strength) Ibf /in 50 XMD 64 kN /m 8.8 XMD 11 Elongation at Peak Load at MD 39 ° MD 39 73.4 °F (25 °C) ° /° 23 XMD 50 /O 23 XMD 50 Ultimate Elongation (at 5% of MD 46 MD 46 Peak Load) at 73.4 °F (25 °C) % 30 XMD 55 % 30 XMD 55 MD 119 MD 530 Tear Strength at 73.4 °F (25 °C) Ibf 70 N 311 XMD 86 XMD 382 MD -0.05 MD -0.05 Dimensional Stability % Change 1 % Change 1 XMD 0.06 XMD 0.06 Low Temperature Flexibility °F 32 14 °C 0 -12 High Temperature Stability °F 230 270 °C 110 132 Granule Loss g 2 0.6 lbf/in 50 MD 70 kN /m 8 8 MD 12 (Tensile Strength) XMD 59 XMD 12 Elongation at Peak Load at ° MD 40 ° MD 40 73.4 °F (25 °C) /° 23 XMD 47 /0 23 XMD 47 Low Temperature Flexibility °F 32 9 0 °C 0 -12.8 S723 -RFS -028 S723 -RFS -028 i Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Parcel Number Expiration: 12/07/2011 Applicant 9475 NE 2 Avenue Miami Shores, FL 33138- 1132060133760 Block: Lot: BANK OF AMERICA & DELOITTE Owner Information Address Phone CeII BANK OF AMERICA & DELOITTE & IOU( P.O. BOX 182588 COLUMBUS OH 43218- Contractor(s) HARPERS AIR, INC. Phone 305 - 266 -1040 Cell Phone Valuation: Total Sq Feet: $ 326,500.00 20067 1 Tons: 10&40 Additional Info: AH AND COND Classification: Residential Approved: In Review Comments: Date Denied: Scanning: 18 Date Approved: : In Review Type of Work: CHANGE OUT Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $198.20 $146.93 $146.93 $65.40 $9,795.00 $54.00 $261.60 $10,666.06 Pay Date Pay Type Invoice # MC -3 -11 -40429 03/23/2011 Check #: 1370 07/11/2011 Check #: 007234 $ 10,566.06 $ 0.00 Amt Paid Amt Due $ 100.00 $ 10,566.06 Available Inspections: Inspection Type: Final In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL PLUMBING, MECHANICAL WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy July 11, 2011 Date July 11, 2011 1 Jun 10 2011 1:36PM Harpers Air Inc. 3052622219 page 3 ACCARD® CERTIFICATE OF LIABILITY INSURANCE �� - r" ( DATE ot roa'' 12/29/2010 L. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETYYEEN THE ISSUING INSURER(S), AUTHORIZED ' REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. - IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policypes) must be endorsed. If SUBROGATION IS WANED, subject to the berms and conditions of the pulley, curtain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In Ileu of such endorsement(s). PRODUCER Herndon &Associates InBUranae LLC 91 Lake Morton Drive PO Box 3608 Lakeland EL 33802 Mi! T Michele Crifaai ext). (863) 688-5495 1 AlXC.Noy (863T6BB -4364 AM1aheleeherndonnet.com PRODUCER D0015534 CUSmaeR_o r I JRER(S} AFFORDING COVERAGE NAIL a INSURED HARPER' 9 AIR, INC 1031 SW 69TH AVE MIAMI PL 33144 INSURER A :FCC/ INSURER B Auto Owners Ins Co 18988 INSURER c: 7/1/2011 INSURER D: $ 1,000,000 INSURER E : DAMAGE TO RENTED INSURERP: COVERAGES - 2010/2011 • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INER I TYPE OF INSURANCE rN^RL y�yyp POLICY NUMBER (N6D11uDO(VYYYPY1 1LADAA/OD l YYYI LIMITS A +,, GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY OCCUR 0L0008756 1 71112010 7/1/2011 EACH OCCURRENCE $ 1,000,000 X DAMAGE TO RENTED 110,000 I CLAIMS -MADE X MEDMEXP (Any ane person)' $ PERSONAL& ACV INJURY 5 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LPAIT APPLIES PER: I Pouc f JS n LOC PRODUCTS - COMP/OP AGG $ 2,000,000 X $ r AUTOMOBILE LIABILITY ANY ALTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OVMBDAUTOS COMBINED SINGLE UNIT' (Ea accent) $ BODILY INJURY (Per person) $ — BODILY INJURY (Per acdder0) $ PROPERTY DAMAGE (Per e) 5 $ $ 8 X UMBRELLA LIRE EXCESS LAS I X OCCUR MANS -MADE 4730457400 7/1/2010 7/1/2011 EACH OCCURRENCE $ 5,000,000 lI AGGREGATE $ 5,000,000 DEDUCTIBLE RETENTION $ 10,000 $ X $ A AAnn ANY OFFICERIMEMBEROCCLUDED? (Mandatory IryeB DESCRIPTION EMPLOYERS' LIABILITY COMPENSATION PROPRIETOR/PARTNERIEXECUTIVE In NH) describe ur er OF OPERATIONS TIN NIA 001HC10A63217 1/1/2011 1/1/2012 yy�g �L� TORY uAMIT5 LF R E.L EACH ACCIDENT $ 500,000 below EL DISEASE -EA EMPLOYEE $ 500,000 E.L DISEASE - POLICY LIMIT 1 500,000 DESCRIPTION OF OPERATIONS! LOCATIONS /VEHICLES (Attach ACORD 10t, Additional Remarks Schedule, If more Alsace I$ required) V 1.err •* re ILIA. QCs TION City Of Miami Shores Village 10050 NE 2nd Ave Miami Shores, FL 33138 ACORD 25 (200W09) INS025(aoosum SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTtIORIZED REPRESENTATIVE G Powell, CPCV /NXCBEL 019W-2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD HARPER'S AIR, INC. GL 11 -C -571 To Reorder Call: The TransForm Group 800 - 226 -2564 or 770- 729 -8585 Fax: 770- 729 -9191 NOTICE OF COMMENCEMENT NCEMENT A RECORDED COPY MIST BE POSTED ON THE JOB SITE AT TIME CIF MST INSPECTION PERMIT NO.'' J) I1 /5 5AXFOLIONO.'i "3o4-013-37CQ STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gties notice that improvements we be made to certain teal property, and in accordance with ith €:hapter 713. Florida Statutes. the following information is provided in this Notice of-Commencement. 111111111111111111111111111111111111 111111111 CFN 2O11RO4r38161 OR Ott 27744 Fs 0767; (fps) RECORDED 07/05/2011 11:56:56 HARVEY RUVIN, CLERK OF COURT IIIAIII -DADE COUNTY, FLORIDA LAST PAGE Space Aimee removal for use of rte One!, 5. Surety: Payment bond requited by owner from contractor. it any) Name. address and phone number; Amount of bond S 6. Lenders name and address. 7. Persons witttin. the State of Florida designated by Owner upon whom notices or other documents may be saved as provided by Section 71S.131)(47.. Ronda Statutes. Name. address and phone number 8. In addition to himsf. Owners &striates the Mowing Remsottfs) to receive a copy of the Lent's Notice as provided In Section 713.13(1)(b), Florida Statutes. Name. address and phone number, 9. Expiration date of this Notice of Commencement: . I.tl,a etpvatt n date a t year ham aerate et femdlng unless 6 ®beta l date r3 Spectral) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THENOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPEFt PAYMENTS UNDER CHAPTER 713. PART 1. SECTION' 713.13. FLORIDA STATUTES. AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE Of COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENL Signatures) of Owne Prepared By Print Name Title /Office 4� eiwaile.e.sr.....— STATE OF FLORIDA COUNTY OF • oozed Offtcer/Director/Partner/Mana Prepared By Print Name Title/Office The toregoing ihst was pcIalaspredged before Re this _to day of To "4_ aD I! BY Ate_ [Index penaliles of oerfury 1 deafare that have read the foregoing; and that time facts stated in It ate irate, Wide best of arty Knowledge and beliei. Signature( OfficerIDirector/Pactner/ who above' By By STATE OF FLORIDA, COUNT OF DADE 1 HEREBY CERTIFY that this is a tie c of the orlgmal filed mtht0office on day of A D 20 WITNESS and and Official Seal. HAR a / • f IN, CLERK, of Circuit and County Courts By '/> 1 D.C. SOUTHEAST GENERAL CONSTRUCTION, INC. 120 N. SWINTON AVENUE • DELRAY BEACH, FL 33444 • PHONE (561) 278 -2776 • FAX (561) 278 -2771 PROJECT: BANK OF AMERICA - MIAMI SHORES 9499 NE 2nd AVE, MIAMI SHORES, FL DATE: 04 /25/11 Page 1 of 1 Ref: Bldg Dept response City of Miami Shores Building Department Miami Shores, FL To whom it may concern: The purpose of this letter is to address your comments regarding the above referenced project. Please find attached the following items as requested: • Copy of Contract • Roofing contractor's licensing information • Submittal of products used to repair new roof penetrations for A/C stands and electrical/mechanical pipes. We hope the review comments are addressed to your satisfaction. Should any section require further detail please feel free to contact our office. Sincerely yours, o . Lapilli Southeast General Construction, Inc CGC #055026 Ph (561) 278 -2776 Fax (561) 278 -2771 1 CBRE CB RICHARD ELL S Work Authorization Master Contract No. LSPSEGEN20120101.0.0 CBRE Real Estate Services, Inc. hereby authorizes the Work and/or Services described hereunder pursuant and in accordance with the terms and conditions of the Master Services Agreement / Contract referenced above. THIS FORM lS NOT VALID %NITRCM IT A WORK Al NiJMBER Project Name: Miami Shores /Shores Villages - HVAC CBRE Work Authorization #: FL0238.10 -006- RCI100757 Issue Date: 4/20/2011 CBRE Project Number. FL.0238.10 Supplier Name: Southeast General Construction, Inc. CBRE Project Manager: Mike Kaplan Supplier Contact: Rabih Bout=s% PIM Manager Tel & Fax: 954 -473 -7055 CW Job Number: RC1100757 Sr. Management Contact: Michael Morabito Estimated Due Date: 6/15/11 BAC Facility Location Name: Miami Shores Project Type: RB= Retail BAU Address: 9499 Northeast 2nd Ave. Project Architect: NA City/State/Zip: Miami Shores / FL / 33138 1. Scope of Work: The scope of work shall include but not be limited to the following: Remove existing air conditioning equipment including disconnect switches, piping and insulation, sheet metal connections, wiring, etc. and install new equipment, disconnect switches, piping and insulation and power and control wiring and reconnect to iC3 system where required. Provide start up, commissioning and testing and balancing services and a Test and balance Report. Provide labor and materials to deliver, lift and install all equipment. Remove all old equipment and debris. Remove and replace all existing ceilings and walls as required. All work is to be performed after regular banking hours and on weekends or in phases so as not to interfere banking center operations. All terms are in accordance with your Master Agreement and Schedule of Values. 2. Exhibits or File Attachments: Please list all drawing(s), plans, specifications, addenda or other documents applicable to this Work Authorization: .3. Instructions: In accordance with your contract for the Project listed above: a. Please provide Consulting Services based on the Hourly Rates Exhibit. not. — exceed: — b. Please prepare a Budget Proposal Form (BPF) or Schedule of Values (SOV) X c. Please begin execution of the Scope of Work for the Project listed above (BPF to $jCost of Services). for the above Scope of Work /SOV/Proposal attached) 4. Pricing: Supplier warrants and covenants to provide the Work and Services for the Price listed below Contractor Work $591,181.50 Authorization : CBRE Project Manager. CBR A5. uthorization: 6. Supplier Acceptance: This form must be physically gned by •, Contractor and the CBRE rsonnel having the appropriate signing authority. r /r Name * /4 //61 rJJ �.� Oat V Title `� ,( O�1 . % g `.x.441 -7 ,�,(��i1 Name Date Title I hereby acknowledge receipt and accept the commission of the Services and/or Work as stated herein for the Price listed above. The signatory represents they are a duly authorized representative of the Contractor vAth contractual authority to bind Contractor with respect to the Services and the Work described herein. 7. Dates: Please define the Commencement Date, Date of Substantial Completion and Date of Final Completion: Commencement Date: Date of Substantial Completion: Date of Final Completion: 4/20/2011 6/15/2011 6 /15/2011 - DATE BATCH NUMBER 1a.CraZilri °Firestone BUILDING PRODUCTS Pourable Sealer S -10 PartsA &B Firestone Item Number: W563587065 DESCRIPTION: Pourable Sealer S -10 is designed for sealing penetration pockets used in conjunction with Firestone roof systems. METHOD OF APPLICATION: 1. Substrates must be free from water, dust, dirt, oil, and other contaminants. 2. After preparation of the penetration pocket per Firestone Details, pour Part B into Part A and mix thoroughly using a drill with a mixing blade. Mix until the Part A material is uniform in color. If material contains gray streaks, mixing should continue. Mix so that material on the bottom and sides of the can is fully circulated and blended. 3. Pour the Pourable Sealer into the penetration pocket. Fill penetration pocket so that water is shed from the actual penetration. 4. Do not thin Pourable Sealer or use partial quantities. COVERAGE RATE: Coverage rate of 200 cu. in (3277 cu. cm) for each mixture of Part A and Part B can be expected. PHYSICAL TROPERTIES: Property Typical Performance Base: Polyurethane Color: Mixed: Black Solvents: Solids: Viscosity: Specified Gravity: Weight/Gallon: Mix Ratio: Pot Life V.O.C. Content: Part A: Light Gray Part B: Black None 100% Part A: 250,000 - 325,000 cps w /Brookfield #7 spindle@ 4 RPM Part B: Thin, Free Flowing Part A: 1.25 Part B: 1.14 Part A: 10.40 lb/gal (1.25 kg /L) Part B: 9.50 lb/gal (1.14 kg/L) 1 can of Part B to 1 can of Part A 30 minutes (max.) at 72 °F (22.22 °C) 0 g/L This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to Installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. SHE 9-10 PART A VIRM !OUR Roui.anLE seuvaf -r0 PART 6' lb, rtro . I: 1303 09/29/2009 PACKAGING: • Part A: One gallon (3.78 L) can • Part B: One pint (.47 L) can • Carton: 4 one - gallon cans and 4 one -pint cans • Carton weight: about 46 lb (21 kg) SHELF LIFE: • Shelf life of one year can be expected when stored in original sealed containers at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C). • Shelf life will be shortened if exposed to elevated temperatures. STORAGE: • Store in original unopened containers, at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C) until ready for use. • When exposed to lower temperatures, restore to room temperature prior to use. • For optimum results, rotate stock to ensure stored material has not exceeded the shelf life of one year. PRECAUTIONARY DATA: • Review Material Safety Data Sheet prior to use. • Avoid moisture contamination. Contact with water can generate explosive pressure in a closed container. • Thinning is not allowed. • Do not contaminate with foreign materials. • Avoid contact with skin. Pourable Sealer is extremely difficult to remove. Disposable gloves are recommended when mixing and dispensing Pourable Sealer. • Avoid breathing vapors. Use only in well ventilated areas. • Cover containers tightly when not in use. LEED INFORMATION: Post Consumer Recycled Content: Post Industrial Recycled Content: Manufacturing Location: 0% 0% South Bend, IN Firestone Building Products Company 250 W. 96"' Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -110 South ast General Constructton Inc. No Exceptions Taken E Make corrections noted fl Revise and Resubmit El Rejected Review is for General Conformance with the Signed intent of the project. Contractor is responsible r all dimensions, quantities, construction techniques, and full compliance with the requirements of the 131 d specifications. By: Date: Tirestone BUILDING PRODUCTS APP 160 Meets ASTM D 6222, Type I, Grade S Tested in Accordance with D 5147 Firestone Item Number: W70APP0162 DESCRIPTION: Firestone APP 160 is a smooth surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade S. APP 160 is ideal for both new construction and re- roofing applications as a base ply, cap sheet, or as a flashing sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 160 application. APPLICATION METHOD: APP 160 shall be installed by fully heat welding the membrane to an appropriate substrate. STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live Toad of the storage area. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative Is authorized to vary this disclaimer. Mineral Release Agent Glass Reinforced Polyester Mat APP Modified Bitumen Bum -off Film Manufactured in an ISO 9001 Registered Facility PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 3.3 ft (1 m) 32' 10" (10 m) 98 sq ft (9.1 sq m) 98 Ib (44.5 kg) 48" x 39" (1.1 m x 1 m) 20 2,020 Ib (918 kg) 26 Stack Firestone APP 160 Squarely In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 8% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN APPROVED APPROVED Firestone Building Products Company, LLC 250 West 96th Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -020 'Firestone BUILDING PRODUCTS APP 160 Meets ASTM D 6222, Type I, Grade S Tested in Accordance with D 5147 Firestone Item Number: W70APP0162 DESCRIPTION: Firestone APP 160 is a smooth surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade S. APP 160 is ideal for both new construction and re- roofing applications as a base ply, cap sheet, or as a flashing sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 160 application. APPLICATION METHOD: APP 160 shall be installed by fully heat welding the membrane to an appropriate substrate. STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. Thls sheet is meant to highlight Firestone's products and specifications and Is subject to change without notice. Firestone takes responsibility for fumishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation If the structural soundness or structural ability to properly support a planned Installation Is in question. No Firestone representative is authorized to vary this disclaimer. Mineral Release Agent Glass Reinforced Polyester Mat APP Modified Bitumen Bum-off Film ,Ma dua redtn;*. ISO 9001iRegistered eciIity PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 3.3 ft (1 m) 32'10" (10 m) 98 sq ft (9.1 sq m) 98 Ib (44.5 kg) 48" x 39" (1.1 m x 1 m) 20 2,020 Ib (918 kg) 26 Stack Firestone APP 160 Squarely In Original Unopened Packaging No More Than Two (2) Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 8% Post Industrial Recycled Content: 0% Manufacturing Location: Beech Grove, IN MOVED Firestone Building Products Company, LLC 250 West 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -020 'Firestone BUILDING PRODUCTS APP 180 FR Meets ASTM D 6222, Type I, Grade G Tested in Accordance with ASTM D 5147 Firestone Item Number: W7OPUWP18OF (UltraWhite m) W7OPWP180F (White) W7OPBP180F (Black) DESCRIPTION: Firestone APP 180 FR is a granule - surfaced APP modified bitumen membrane. It consists of select asphalt, modified with atactic polypropylene, and reinforced with a non -woven 190 g /m2 (5.6 oz /yd2) polyester mat, enhanced with continuous glass fiber strands in the machine direction. The combination results in a flexible, yet durable roofing membrane that exceeds the performance requirements of ASTM D 6222 Type I, Grade G. APP 180 FR is ideal for both new construction and re- roofing applications as a cap sheet in single or multi -ply applications. Low slope roofs of any size, even those with numerous penetrations, may accommodate a Firestone APP 180 FR application. . Firestone APP 180 FR with UltraWhite granules has a highly reflective surface designed to meet national, state and local energy code requirements. Solar Reflectance Index (SRO = 89 SRI calculated using the ORNL (DOE) calculator, ASTM E 1980 -01 UltraWhite granules can help achieve points in the U.S. Green Building Council's LEED® rating system and meet the requirements for California's Title 24 regulations. APPLICATION METHOD: APP 180 FR shall be installed by fully heat welding to an appropriate substrate. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. Granule Surfacing Glass Reinforced Polyester Mat APP FR Modified Bitumen auacturem�_ al ISO 90, 1_; Rem ®ist> tl ,agl1!,,., , STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 39.4" (1 m) 32' 10" (10 m) 98 sq. ft (9.1 sq. m) 107 lb (46.5 kg) 48"x 39" (1.2 m x 1 m) 20 2,108 (958 kg) 21 Stack Firestone SBS Premium FR Squarely In Original Unopened Packaging No More Than Two (21 Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 6% Post Industrial Recycled Content: 00/0 Manufacturing Location: Beech Grove, IN (APPROVED( Note: Dade County Approval of UltraWhite products is pending Firestone Building Products Company, LLC 250 West 96th Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -028 Initial Weathered Solar Reflectance 0.72 Pending Thermal Emittance 0.90 Pending Rated Product ID 0029 Licensed Manufacturer ID 0608 `"Ii{ .,,A Far16 Ga4. a. Rai h�i9 Classification Production Line Cool Roof Rating Council ratings are determined for a fixed set of conditions, and may not be appropriate for determining seasonal energy performance. The actual effect of solar reflectance and thermal eminence on building performance may vary. Manufacturer of product stipulates that these ratings were determined In accordance with the applicable Cool Roof Rating Council procedures. Solar Reflectance Index (SRO = 89 SRI calculated using the ORNL (DOE) calculator, ASTM E 1980 -01 UltraWhite granules can help achieve points in the U.S. Green Building Council's LEED® rating system and meet the requirements for California's Title 24 regulations. APPLICATION METHOD: APP 180 FR shall be installed by fully heat welding to an appropriate substrate. This sheet is meant to highlight Firestone's products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone's published product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. Granule Surfacing Glass Reinforced Polyester Mat APP FR Modified Bitumen auacturem�_ al ISO 90, 1_; Rem ®ist> tl ,agl1!,,., , STORAGE: All material must be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of 40 °F (4 °C) and a maximum of 140 °F (60 °C) so that it will be a minimum of 40 °F (4 °C) at the time of application. If material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner not to exceed the allowable live load of the storage area. PACKAGING: Roll Width: Roll Length: Net Coverage: Roll Weight: Pallet Size: Rolls Per Pallet: Weight Per Pallet: Pallets Per Truckload: 39.4" (1 m) 32' 10" (10 m) 98 sq. ft (9.1 sq. m) 107 lb (46.5 kg) 48"x 39" (1.2 m x 1 m) 20 2,108 (958 kg) 21 Stack Firestone SBS Premium FR Squarely In Original Unopened Packaging No More Than Two (21 Pallets High PRECAUTIONS: 1. Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of physical damage. 2. Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone Modified Bitumen membranes. 3. This product is not intended for application in hot applied asphalt. Contact Firestone Roof Solutions Department for specific recommendations. 4. Refer to Material Safety Data Sheet for APP Membranes and Flashing. LEED INFORMATION: Post Consumer Recycled Content: 6% Post Industrial Recycled Content: 00/0 Manufacturing Location: Beech Grove, IN (APPROVED( Note: Dade County Approval of UltraWhite products is pending Firestone Building Products Company, LLC 250 West 96th Street, Indianapolis, IN 46260 Sales: (800) 428 -4442 • Technical (800) 428 -4511 www.firestonebpco.com S723 -RFS -028 APP 180 FR Meets ASTM D 6222, Type I, Grade G Tested in Accordance with ASTM D 5147 T,restone BUILDING PRODUCTS Dimensions and Mass English Metric Property Unit ASTM Minimum Firestone Nominal Unit ASTM Minimum Firestone Nominal Product Thickness mil 160 162 mm 4.1 4.1 Net Mass lb/100 ft2 85 109 g /m2 4,149 5,320 Bottom Coating mil 30 43 mm 0.8 1.1 Physical Properties Peak Load at 0 °F ( -18 °C) (Tensile Strength) Ibf /in 60 MD 120 kN /m 10.5 MD 21 XMD 98 XMD 17 Elongation at Peak Load at 0 °F ( -18 °C) o /0 10 MD 27 o /0 10 MD 27 XMD 25 XMD 25 Peak Load at 73.4 °F (25 °C) (Tensile Strength) Ibf /in 50 MD 79 kN /m 8.8 MD 14 XMD 64 XMD 11 Elongation at Peak Load at 73.4 °F (25 °C) o /° 23 MD 39 o /° 23 MD 39 XMD 50 XMD 50 Ultimate Elongation (at 5% of Peak Load) at 73.4 °F (25 °C) % 30 MD 46 % 30 MD 46 XMD 55 XMD 55 Tear Strength at 73.4 °F (25 °C) Ibf 70 MD 119 N 311 MD 530 XMD 86 XMD 382 Dimensional Stability % Change 1 MD -0.05 % Change 1 MD -0.05 XMD 0.06 XMD 0.06 Low Temperature Flexibility °F 32 14 °C 0 -12 High Temperature Stability °F 230 270 °C 110 132 Granule Loss g 2 0.6 Peak Load at 73.4 °F (25 °C) (Tensile Strength) lbf/in 50 MD 70 kN /m g 8 MD 12 XMD 59 XMD 12 Elongation at Peak Load at 73.4 °F (25 °C) o /0 23 MD 40 o /0 23 MD 40 XMD 47 XMD 47 Low Temperature Flexibility °F 32 9 0 °C 0 -12.8 S723 -RFS -028