Loading...
SGN-11-1881Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 165428 Permit Number: SGN -10 -11 -1881 Scheduled Inspection Date: January 19, 2012 Inspector: Bruhn, Norman Owner: , SHORES SQUARE INVESTMENTS Job Address: 9005 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: ATLAS SIGNS OF LAKE WORTH INC Permit Type: Sign Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1132060110060 Phone: (561)863 -6659 Building Department Comments INSTALL WALL SIGN ON SOUTH ELEVATION Passe Failed /-1 Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments z c-- January 18, 2012 For Inspections please call: (305)762 -4949 Page 7 of 23 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC20 RECEIVED OCT 12 2011 Permit No. ¶1 N 1 1-1B51 Master Permit No. Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): SW G .S6W/W/1c Iil1/trA'& U6 Phone#: Address: 370 l3 Igo i2 D ET( t o City: /11 / /TM! State: FL Tenant/Lessee Name: `—C7 � ( k) A • Phone#Pf g q. - C� —' e� I 4 JOB ADDRESS: 90os 13 if C A /,YC /3 LVkO City: Miami Shores County: Miami Dade Zip: 3y or Folio/Parcel #: I t - 3a O49- 0 ( ( — 00 (Q0 Is the Building Historically Designated: Yes NO ✓ Flood Zone: /�'' 0C' - Al Jt'Ji‘C /T CONTRACTOR: Company Name: TL 45 Snit/ 1)F/965- 7'-o4l Phone#: al io WY Address: 107 ? VII 7 /i t 14 Ham' 0 1.02 City: 11/t ?7 / PL/1 13 CA Cl/ state: FL Zip: a Qualifier Name: ()EF /c"RY AO INatft State Certification or Registration #: ,S OW02 0 H Certificate of Competency #: Contact Phone #: ro /- W " ‘G-r`l Email Address: ()CNN , (2 4? ,47Z/{J J%(,N we 7/WI' . G/l DESIGNER: Architect/Engineer: 71/Z:00011 i' "le ANL If Phone#: //• NI - Oil Phone#: ?'G3- grf Value of Work for this Permit: $ 2-1 L v, Square/Linear Footage of Work: 3 Type of Work: °Addition °Alteration °New ORepair/Rep • ' +lition pp�� S ®� ( Description of Work: �R -��, � � �'U � I � � ******* * *** * * * * * * * * * * * * * * * * * * * * * * * * * ** ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ SO Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL 1a'L+'g NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Si The Owner or gent en was acknodvled who is personally kno , by L) o me or who has produced As identification and who did take an oath. The foregoing instrument was acknowledged before me this l4e day of - ,20�� ,by '� who is personally known to me or hh ee�� . (, whhy� NOTARY P Sign: as R61BIte an oath. E OF FLORIDA EE0Q3019 6 Print: _) My Commission Expires: * * * * * * * * * ** * * * * * * * * * * ** * * * * * ** * ***+ ray***** **** ** **** * * * ***** * *** * * * *** * * * ** * * ************** * * **** *** ** ** APPROVED BY Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) l/ zoning Clerk Permit No: 11- Job Name: Date: Miami Shores Vivage Building Department Zoning Critique Sheet 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. David Daquisto Planning Director 305 - 795 -2207 A 8 i Ip� p 1 1 4 EXISTING COMMERCIAL BUILDING Z0NE: 8-2 4, CONCRETE ADA COMPLIANT DETECTABLE WARNNO ADA COMPLIANT RAMP PROPOSED 6OWDRS 40 TRAFFIC PATTERN DIRECTION (NOT A PAVEMENT MARKING) PAVEMENT MARKING MIN VEHICLE OUTLINE FOR I 0RIVE-THRU STACKING LwNnLVAeE BUFFER 2t &o7• [t72, ,.. POLE ME POE MINTED TRANSVORMER ^.. 00 NOT NE 90TH STREET Z0NE: 8-2 PROPS CONDMONS Saws et Oeacloner Addrese P Set 000016 nretl Use 2on8W Mallet 9eatton. Township. Nano No. of 5)4466/ Floont Flood Elevation TO BONN NA 8000 Atrium nsMOU10 1.01e. 1.01e. NJ 08084 TO Bank -8005 5 81 FL/areal betRation Bank Commercial 8 -2 NSIENT BUSINESS 5-08. T -83, 8-42 1 zone 48 AE (Elevation 8) FIRM Mop% 120 110 03087 (8/18/82) CODE COMP DANCE CODE REQUIRED PROVIDE) PARKING ADA PARTONO 1 SPICE / 250 SO FT =18 24 1 -25 STALLS - 1 ADA STALLS 1 GREEN SPACE gas 262 DRIVE -TFOG1 STACK/NO 4 SPACES 4 SETBACK FRONT 25 FT 74.1 FT SIDE (NEST) 5 FT 45.8 FT SIDE (FAST) 5 FT 17.7 FT REAR 8 FT 40.8 FT IA BUFFER FRONT 5 FT 5 FT SIDE (FAST) B FT 8 FT SIDE (NEST) 5 FT 0 FT REAR 5 FT 8 FT AREA BREAKDOWN FEET TOTAL 0.83 27,7213 PERNOUS 0.15 8.580 23.732 IMPEMAOUS 0.48 21,148 78.272 5444004 0.08 3.084 14.302 Vehicular Use 0.37 15.138 88.100 SItlew4k 0.02 1.548 3.782 PARKING E1001FN0 SHOPPING CENTER 43.838 SQ. FT. 281 SPACES. NCLUDNO 10 H.C. PROPOSED PARKNG (REQUIRED) (43.038 50. FT. - 8,431.87 50. FT. + 3,984 SO 11.) /250 INCLUDING PACES, H.C. PROPOSED PARKING (PROVIDED) 248 SPACES, INCLUDING 10 H.C. SPACES LAND USE DATA E0081160 USE RETAIL (FORMERLY A BLOCKBUSTER 51046) PROPOSED :ism 3,084 5F FL PROIUIY't 3 REAR ATTACHED DINE -THRU LANES (BANK) MUG ZONING 8 -2 TRANSIENT BUSINESS PROPOSED z0NIN0 8 -2 TRANSIENT BUSINESS 1. ROOF TOP MECHANICAL EQUIPMENT IS TO BE SCREENED PER OW CODE 2. ALL EIEVATO45 SHOWN ARE IN REFERENCE TO THE 8440WN8t AND MUST BE VERP1 D BY THE GENERAL CONTRACTOR AT G90IN08REM4. 3. 9UEON0 DIMENSIONS SHOWN ON THE COAL ENGHEERNO PLANS NW FOR REFERENCE PURPOSES ONLY. WEN LAYING OUT THE PROP0SD BUGLING FOUNDATION, THE CONTRACTOR SHALL Ug 1444 ARCHITECTURAL PLANS FOR MOT 8044240 WO490NS. 4. 9GNAGE REQUIRES SEPARATE SCRAM PER151. 8 LIGHTING LEVELS BALL NOT =EEO 0.5 FOOT CANDLES AL040 165DENRAL AREAS LEGAL DESCRIPTION OF SHOPPING CENTER WHERE SUBJECT PROPERTY IS LOCATED. (PER Ot4CUa. RECORDS 80CS 24432, PAGES 4518 -4514. M -1665.) LOT 8 LESS THE EAST 30 FEET AND ALSO L65 THE NORTH 25 FEET SEWER AND LO15 5. 7. AND 8, LESS THE NORTH 28 FEET OF SAME, AND ALSO THAT PART OF LOT 8 NOW SITING USED AS P0511C mom 0840084 AS FEDERAL HIGHWAY ALSO KNO'M4 AS 6SCAYNE BOULEVARD AND 1FHOSE PARIS O EACH LOTS 8 9, 10 AN0 11 WHICH LE SOUTH OF FEDERAL HIGHWAY ALSO MOWN AS 81SCAYNE BOULEVARD, ALL OF SAID LOTS BEND O MARY PARK, ACCORDING TO THE PLAT THEREOF. AS RECORDED N PLAT BOOK 4. PAGE 110, OF SE 02446 !moms OF MIAMI-DADE COUNTY, FL6i0A LEGAL DESCRIPTION OF SUBJECT PROPERTY AUTH0RE0 BY STONER @ ASSOCIATES, INC. %MOUT THE BENEFIT OF A TITLE SEARCH AND BASED ON FOUND PROPERTY CORNERS AND SHORT VERSION LEGAL DES4RIPTON 511094 04 MIAMI -DADE PROPERTY APPRAISER'S SEMITE FOR PROPERTY FOLIO No. 11- 3208 - 011 -0080 COMMENCE AT THE SOUTHEAST CORNER O LOT 5, A9811RY PAW5 ACCORD= TO THE RAT 140064, AS RECORDED N RAT 8064 4. PACE 11Q OF THE PUBLIC RECORDS OF WABA -DARE COUNTY, FLLLQDA; T4414CE SOUTH 0780'21 WEST. ALONG THE SOUTH LAZE O SAID ASBURY RAT AND ALONG THE NORTH MGM WAY UNE OF N.E. 80th STREET. A DISTANCE OF 47801 FEET TO THE PORT OF THENCE C04T61E SOUTH 878021 'EST. ALO40 SAID SOUTH LINE OE SAID ASB6RY PLAT AND ALONG SAID THE NORTH WORT OF NAY LNE OF N.E. 90th SWEET. A DISTANCE OF 21807 FEET; THENCE NORTH 0264'80 'EST, A DISTANCE OF 12.20 FEET TO THE SOUTEASTERLY RIGHT O WAY LNE OF 99.AYNE BOULEVARD (STATE ROAD No. 8 - US. WOIWAY No 1R THENCE NORTH 302788' EAST, ALONG SAID SOUTHEASTERLY M04T OF WAY LNE OF 84SGYNE BOULEVARD (STATE ROAD No. S - U.S. HIGHWAY No. 1). A DISTANCE OF 21083 FEET; maim NORTH 878021' FART, A O5TMLCE O 85.131 THENCE SOUTH 0288'02' EAST, A DISTANCE O 177.00 FEET TO TIE PONT OF BEGINNING. LT 0_ a m CLI DUN in DATE 01 -04 -2010 PROJECT NO 042701308 SHEET NUMBER C -105 Align- E03 10'-2 1/2" 9' -1 1/2" 3'-4 1/8" 8 -5/8° 5'-0 3/40 Align ILLUMINATED LETTER SET: 3/4" = 1'-0" Square Footage: an Align 8' -13/4° Allowable Formula and Calculation Proposed Channel Letter Building Identification at 3.33' x 10.21' = 34.0 Total Square Feet gITY ?°1 e AO— Miami Shores Village APPROVED BY DATE ZONING DEPT 1/8" LD 7328 Light Diffusing White Acrylic with Negative Cut 3M 3632 -5830 Translucent Light Green Vinyl Graphics , (i/ ld?9.1( BLDG DEPT .`,LJIiJFCT TO COMPLIANCE WITH ALL FEDERAL TAT[ AND COUNTY RULES AND REGULATIONS '77731 f OCT 1 2 2011 9 w Bank Letter Set TD Shield Construction .040 Aluminum Backs and Retums Painted PMS 361 Green / Retums 5° Deep Faces 1/8" LD 7328 Light Diffusing White Acrylic with Negative Cut 3M 3632 -5830 Translucent Light Green Vinyl Graphics Retainer Aluminum L -Type Retainer painted PMS 361 Green and Secured with No.8 Pan Head Screws Illumination Permlight EL -Plato 747 -WHT El Plato 6500K LED Modules Mounting 3/8" Off Wall On Spacers With All Electrical and Wiring Concealed Behind Facade / See Detail Sheet Al -P Bank Letter Set Construction .040 Aluminum Backs and Retums Finished Gloss White Enamel Paint/ Retums 5" Deep Faces 1/8 LD 2447 Ught Diffusing White Acrylic with 3M Dark Green No. DN0023 Perforated Vinyl Overlay (White at Night) Trim Cap 1" Gem Brand Trim in Hunter Green No. 2162 Secured with No.8 Pan Head Screws Illumination Permlight Nitro 777-WHT 6500K LED Modules Mounting 3/8" Off Wall On Spacers With All Electrical and Wiring Concealed Behind Facade / See Detail Sheet A1-P 1 1• 1 1 9 SOUTH ELEVATION : 1/8" =1'-0" atlas SION INDUSTRIES FFLORIDA r r GEORGIA CORPORATE HEADQUARTERS 1077 Wesl Blue Heron Blvd.. West Palm Beach, Florida 33404 PHONE: (561) 863.6659 / 800.772.7932 FAX: (561)863.4294 NORTHEAST DIVISION 707 Commerce Drive. Concord. North Carolina 28025 PHONE: (704) 788.3733 / 800.772.7932 FAX: (704) 788.3843 www.atlassignindustries.us (1) moor agagage UNDERWRITERS LABORATORES INC. LISTED U113111011151G11111 07/29/2010 J. Abreu Iloing No. A24849 As Shown 9005 Biscayne Blvd. Miami Shores, Florida r B. Hodge A2 ID Bank/Miami Shores, FL/9005 Biscayne Blvd. Recestripe Construction .040 Aluminum Backs and Retums Painted PMS 361 Green / Retums 5" Deep Faces 1/8" LD 7328 Ught Diffusing White Acrylic with 3M Ught Green No. 3632 -5830 Vinyl Overlay Retainer Aluminum L -Type Retainer painted PMS 361 Green and Secured with No.8 Pan Head Screws Illumination Permlight 747 -WHT El Plato 6500K Led Modules Mounting 3/8" Off Wall On Spacers With All Electrical and Wiring Concealed Behind Facade / See Detail Sheet Al -P 1 1• 1 1 9 SOUTH ELEVATION : 1/8" =1'-0" atlas SION INDUSTRIES FFLORIDA r r GEORGIA CORPORATE HEADQUARTERS 1077 Wesl Blue Heron Blvd.. West Palm Beach, Florida 33404 PHONE: (561) 863.6659 / 800.772.7932 FAX: (561)863.4294 NORTHEAST DIVISION 707 Commerce Drive. Concord. North Carolina 28025 PHONE: (704) 788.3733 / 800.772.7932 FAX: (704) 788.3843 www.atlassignindustries.us (1) moor agagage UNDERWRITERS LABORATORES INC. LISTED U113111011151G11111 07/29/2010 J. Abreu Iloing No. A24849 As Shown 9005 Biscayne Blvd. Miami Shores, Florida r B. Hodge A2 ID Bank/Miami Shores, FL/9005 Biscayne Blvd. 10' -21/2° 9' -1 1/2° 3' -4 1/8" 8-5/8° 5'-0 3/4" E04 ILLUMINATED LETTER SET: 1/2" = 1' -0" SIGN LOCATED @ WEST ELEVATION 1111 II5I.I.IIIIIP" 0 SECTION @ TD SHIELD 6'-1 3/4° Anchor Points ANCHOR SCHEDULE: TD Shield = (4) - 1/4" x 2/14" Tapcon screws Bank Letters = (4) - 1/4" x 21/4" Tapcon screws per letter Stripe = (6) - 1/4" x 21/4" Tapcon screws SHIELD SPECIFICATIONS: 1: Shield cabinet constructed of .063" aluminum backs and retums . 2: Brake formed aluminum retainer fastened to retums with no.8 pan head sheet metal screws. 3: 1/8" Thick acrylic faces with vinyl overlays. 4: All sign elements secured to fascia with 1/4" x 2 1/4" Tapcon screws four (4) per letters and logo. 5: Low voltage LED internal illumination in all elements. 6: 1/2" UL Usted and approved Sealtite connector with ground lug and ground wire. 7: 1/2" UL Listed and approved Sealtite sleeve thru wall and letter to letter behind wall. 8: UL Listed and approved 2" x 4" weather proof bell box with 20amp / 120vac disconnect switch mounted to wall. Exact location to be determined. 9: Drain holes two (2) per letter as per NEC 600-8. 10: Wall is stucco over masonry block. 11: Metal can with removable cap mounted behind wall. 12: Low voltage LED power packs as needed. See electrical data for total amps and quantity. 13: '1/2" UL Listed and approved Sealtite housing all branch wiring. 14: UL Listed and approved customer supplied junction box per NEC 300 -14A one per circuit with UL Usted and approved 20amp snap switch disconnect. 15: Primary electrical to junction box in approved electrical conduit by others to within five feet of sign area. 00 LETTER & STRIPE SPECIFICATIONS: 0 1: Letters and stripe constructed of .040" aluminum backs and returns . 2: 1" Jewelite trim cap chemically bonded to acrylic face and fastened to retum with #8 pan head screws. 3: 1/8" Thick acrylic faces with vinyl overlays. 4: All sign elements secured to fascia with 1/4" x 2 1/4" Tapcon screws four (4) per letters and logo. 5: Low voltage LED intemal illumination in all elements. 6: 1/2" UL Listed and approved Sealtite connector with ground lug and ground wire. 7: '1/2" UL Usted and approved Sealtite sleeve thru wall and letter to letter behind wall. 8: UL Listed and approved 2" x 4" weather proof bell box with 20amp / 120vac disconnect switch mounted to wall. Exact location to be determined. 9: Drain holes two (2) per letter as per NEC 600-8. 10: Wall is stucco over masonry block. 11: Metal can with removable cap mounted behind wall. 12: Low voltage LED power packs as needed. See electrical data for total amps and quantity. 13: 1/2" UL Usted and approved Sealtite housing all branch wiring. 14: UL Usted and approved customer supplied junction box per NEC 300 -14A one per circuit with UL Listed and approved 20amp snap switch disconnect. 15: Primary electrical to junction box in approved electrical conduit by others to within five feet of sign area. CIRCUIT #29 0 ILL 0 1 INIIItOI IIIIIiNIIIINIIIIIIIIIII II 1TI1 ill) PANELBOARD LP -SP 5" e SECTION @ BANK AND STRIPE BUS LOAD FOF5 APPS A BBSC AMPS POLES LOAD A BAINSC C 10 OFFICE UGHTING 1 20 1 1+,12 20 1 OFFICE RECEPTACLES 7.5 10 1 20 31„14 20 1 9 7 CORRIDOR/R.R. UGHTING 1 20 5 20 1 ` 7.5 95 OFFICE LIGHTING 1 20 7 1„16 1„18 1..11.. 20 1 7.5 10 - " 1 20 9 20 1 R.R. GFFS 2 12,9 WAREHOUSE LIGHTING I 20 111,.11 20 1 OFFICE RECEPTACLES 9 129 - 1 20 1 1„11 «:+ •+IUI 111r 20 1 REFRIGERATOR 10 12.9 1 20 151.1111 • 20 1 BATH. (GFl) 3 7.5 WAREHOUSE RECEPTACLES 1 20 1 1r 20 1 OFFICE RECEPTACLES 6 7.5 - 1 20 19: . 20 1 ° 7.5 9 1 20 1::::r 30 2 WATER HEATER 24 12 PYLON SIGN 1 20 2 1 1 1 24 12 SIGN LIGHTING 1 20 2 ., SPARE _Ili. , ,I/1I, < SPARE SIGN LIGHTING 1 �IUI ''' ) SPARE SIta" ut.nrwe 1 Al ,3 ���I ��UU 1/110 I�: SPARE 12 EXHAUST FAN 3 21 .3 SPARE 12 12 A/C WALL UNIT 3 21 _ SPARE SPARE 3 SPARE SPARE 3, 4111111 SPARE SPARE SPARE ELECTRICAL DATA Total AMPS Circuits Vls@Ie Disconnects Power Supplies (2)= (1)@.95&(1) @4.0 ELECTRICAL NOTES 1. Al materials and fasteners meet 3004.4 2.140 electrical components are UL listed and approved. 3. Sign grounded according to NEC 6007.7 4. Signs manufactured and Dated NEC 600.3 and marked per NEC 600.4. 5. AD branch circuits per NEC 600.5(6).1 or (8).2. 6. All Signs controlled by photocell or time dock per FRC 13-015. (ABC).1.4. 7. One visible 20 amp disconnect per sign par circuit per NEC 600.6(A).1 OWNER: CONTRACTOR: TOTAL LOAD= 28700 VA TOTAL AMP LOAD " 80 AMPS TD BANK ATLAS SIGN INDUSTRIES 2290 AVENUE L WEST PALM BEACH, FL. 33404 (561) 863-6659 LIC. #ES0000204 1 E TD Bank, Miami Shores - West Elevation Logo 9116111 Logo is largest area for wind load Logo to Building: mounting: Four (min) %" x 2 %a" Tapcons Allowable pullout tension: 500# in concrete masonry at minimum 11/2” embedment (Tapcon technical spec) 1 4:1 safety factor: pullout = 25% x 500# =125# allowable Wind loading: 125# x 1.33 =166# allowable pullout per Tapcon . Wind load perASCE 7 -05, method 1, components and cladding V = 146 mph (Miami -Dade Code) g Roof height 15' Least horizontal dim. =16; Zone 5 = 3' from comer (Fig. 6 -3) 1 1 0 a 2 As witnessed by my seal, I certify that the sign or letter attachment method meets or t, exceeds the requirements of the 2009 FBC for 146 MPH wind Toad. Z Sign located in Zone > 3' from comer Effective wind area < 10 sf Wind pressure away from wall: P" = 41.62 psf (Fig 6 -3) Lambda = 1.21 (Fig 6 -3); P' = 1.21 x 41.62 = 50.4 psf Aye "= 3.35x3 =10.1 sf F = 50.4 psf x 10.1 sf = 509# pullout on cabinet Pullout load / TA = 509# / 166#= 3.1 fasteners Four (4) - %" x 2 %40 Tapcons - OK Code Provisions for Sign Installation Code Edition: 2007 Florida Building Code, Revised 2009 Wind Load perASCE 7 -05, (Florida Building Code 1609.1.1) Exposure C Occupancy Category II: (Table 1 -1) Importance Factor 1: (Table 6 -1) Wind Speed 146 mph (3 sec. gust): (Fig. 6-1B) ENGINEER INFORMATION NAME: Theodore M. McAnlis, P.E. ADDRESS: P.O. Box 14724 North Palm Beach, Florida 33408 E -Mall: ted.mcanlis @hotmail.com LICENSE No. 19239 ) - .5/2 %, m 0 3, 8 c 0 3 3 a 8 s On 0. 0 arias SIGN INDUSTRIES FLORIDA NOR QAROLINA GEORGIA CORPORATE HEADQUARTERS 1077 West Blue Heron Blvd., West Palm Beach, Florida 33404 PONE: (561) 863.6659 / 800.772.7932 FAX: (561)863,4294 NORTHEAST DIVISION 707 Commerce Drive, Concord, North Carolina 2802 PHONE: (704) 788.3733 / 800.772.7932 FAX: (704) 788.38431 www.atlassignindustries.us UNDERWRITERS LABORATORIES INC. LISTED A_: N19nber - - - Revision Description ■ ■ Date Approved by Dale =APPROVED As SWIWs =APPROVED AS Me L DOINST 8803139B0 BF, 011M111111 P4 81 Bank 9005 Biscayne Blvd. Miami Shores, Florida m° 09/16/11 J. Abreu PmJect Mama Orom B. Hodge 0mvba Ab. A24850 -P 180 As Shown A3 -P TD Bank/Miami Shores, FL/9005 Biscayne Blvd.