SGN-11-1877Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 165424 Permit Number: SGN -10 -11 -1877
Scheduled Inspection Date: January 19, 2012
Inspector: Bruhn, Norman
Owner: , SHORES SQUARE INVESTMENTS
Job Address: 9005 BISCAYNE Boulevard
Miami Shores, FL 33138-
Project: <NONE>
Contractor: ATLAS SIGNS OF LAKE WORTH INC
Permit Type: Sign
Inspection Type: Final
Work Classification: New
Phone Number
Parcel Number 1132060110060
Phone: (561)863 -6659
Building Department Comments
INSTALL NEW DOUBLE FACE MONUMENT SIGN
Passe
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
January 18, 2012
For Inspections please call: (305)762 -4949
Page 5 of 23
12/05/2011 11:02 FAX 1 800 685 7530
DATA SCAN FIELD SERVICES
Ijooi
TRANSMISSION OK
TX /RX NO
RECIPIENT ADDRESS
DESTINATION ID
ST. TIME
TIME USE
PAGES SENT
RESULT
* * * * * * * * * * * * * * * *** * **
* ** TX REPORT * **
* * * * * * * * * * * * * * * * * * * **
2020
915617272449
12/05 11:02
00'31
1
OK
Invoice
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138 -0000
Phone: (305)795 -2204 Fax: (305)756 -8972
For Inspections please call: (305)762 -4949
'Return to:
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138 -0000
Bill To
SHORES SQUARE INVESTMENTS
SHORES SQUARE INVESTMENTS
3850 BIRD Road 800
MIAMI, FL 33146-
Invoice Number. SGN -10 -11 -42415
Invoice Date: October 28, 2011
Permit Number: SGN -10 -11 -1877
Bond Number.
Comments:
Date
Fee Name
10/28/2011 Plan Review Fee (Engineer)
Fee Type
Calculated
Fee Amount
$60.00
Total Fees Due:
$60.00
MIAMI SHORES VILLAGE
10050 NE 2ND AVE
MIAMI SHORES, FL 33130
(305) 795 -2207
Phone /Web
ID: 75175372
12/05/11
Batch A: 104
Payments
Ref 0: .0001
:52:22
AVS: ZIP MATCH 2
I4'
Date Pay Type
12/02/2011 Credit Card
Check Number Amount Paid
$60.00
Change
$0.00
Total Paid:
$60.00
Total Due: $0.00 I
Invoice
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138 -0000
Phone: (305)795 -2204 Fax: (305)756 -8972
For Inspections please call: (305)762 -4949
'Return to:
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138 -0000
Bill To
SHORES SQUARE INVESTMENTS
SHORES SQUARE INVESTMENTS
3850 BIRD Road 800
MIAMI, FL 33146-
Invoice Number: SGN -10 -11 -42415
Invoice Date: October 28, 2011
Permit Number: SGN -10 -11 -1877
Bond Number:
Comments:
Date
Fee Name
10/28/2011 Plan Review Fee (Engineer)
Fee Type
Calculated
Fee Amount
$60.00
Total Fees Due:
$60.00.
MIAMI SHORES VILLAGE
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
(305) 795 -2207
Phone/Web
ID: 75175372
1205/11
Batch H: 104
Payments
Ref 0: 0001
09:52:22
AVS: ZIP MATCH Z
VIsR
150'`
RPPr Code: 087361 Invoice #:
CVV2 Code: MATCH M
Trans ID: 08133953542988
Amount:
Tax:
Total:
Customer COPY
Date Pay Type
12/02/2011 Credit Card
Check Number Amount Paid
$60.00
Change
$0.00
Total Paid:
$60.00
Total Due: $0.00 II
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
BUILDING
PERMIT APPLICATION
FBC20
Permit Type: BUILDING ROOFING
Permit No.
RECEI VEL;
OCT
��,,12 2011
BY: 515-'
Master Permit No.
OWNER: Name (Fee Simple Titleholder): /i26 5610/1/4- 1/1fit ?7fr f LL C Phone#:
Address: 370 /3 112 19 0 S 7E tiro
City: /ci / //Ml State: FL
Tenant/Lessee Name: ) N. A .
zip: 3.2 /yW
Phone #: q —G31-5 — -114 1
Email:
JOB ADDRESS: IOKS /3 if A y,vC- /3 LV19
City: Miami Shores County: Miami Dade Zip: 31137
Folio/Parcel #: j t r- Ja O(p-- Ca 1 —OD(00
Is the Building Historically Designated: Yes NO ✓ Flood Zone:
CONTRACTOR: Company Name: /7 TC 4.s nit/ ►,v-9 t Phone#: g6 ( 8'63- 6tj f
Address: 107 i 1,11.3 7 A C UE- / -fE io,' 01k0
City: 11/1,77 P 142/7 6 CA Cl/ State: F L Zip: 73 96)
Qualifier Name: t) E (7L'R y A 0 iN gI f t Phone#: 0/ l/3 ` 101
State Certification or Registration #: LS OoC'02 011 Certificate of Competency #:
Contact Phone #: .i-(71 T(i _ to Emil Address: daN1'/ i2 @ /f7Z4J .l /fr /4*17R /a. US
DESIGNER: Architect/Engineer: Wit-00 �' MC%iNLIS Phono#:
Value of Work for this Permit: $ - It—CT It-CT Square/Linear Footage of Work: 2
Type of Work: UAddition Alteration `
rNew ORep ' lace ❑Demolition
Description of Work: �'' `�� � N ✓ 1 C'Pr�
` ; •s
***e******m* * * * **** * * *** * * *•x**a.ee**** ** Fees * * *** * *** * * * ** n ** * ******* * *** * *44* * *** *******
o4)
Submittal Fee $ n l9 Permit Fee $ /S2 CCF $ CO /CC $
Scanning Fee $ Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $ C C
TOTAL }EE NOW DUE $
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose properly is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
O
Si
?.�' Signature
Owner or Ag dontractor
goig trume.t was ackto*led , , The foregoing instrument was acknowledged before me this L 1-
, by �` �f y y , day of 1 iJ , 20 t L , by -TA-
me or who has produced who is personally known to me or who has produced 1 T�
As identification and who did take an oath. as i• :;' ,� :;, MAW R.
SMITH
Yf` ..+;a v an oath.
NOTAR
PUBLIC: NOTARY P • � ���M STATE OF FLORIDA
mm# EE063019
Sign:
Print: T .
Sign
Illiilli
�'. -;�> � EXPIRES: Apra 4, 2014
y Commission Expires:
My Commission Expires:
******•r.s ****• nor* x.• s• s**x•.x.s*.sa.a.•x*********** • .x.•x•xs•s•+x•x.x*• *** *•x******* * *** * * ********
APPROVED BY Plans Examiner
* * * * * * * * * * * * * * * * * * ** * * * * * **
17
Zoning
1 cG e:. L- Structural Review Clerk
"ells p,
(Revised 07!10 /07)(Revised 06/10/2009)(Revised 3/15/09)
1
EXISTING
COMMERCIAL
BUILDING
ZONE: B-2
A
/ 4 iu
i
3 A'
RMJiT
a (, (-)/ gl"
! /L
1! a�
13 REQUIRED PAM= / /
W RSt0A800 WN8BCAPE BUFFER
/
40
SPAR PEET
LEGEND
CONCRETE
ADA COMPLIANT
DETECTABLE WARNING
ADA COMPLIANT
RAMP
TRAFFIC PATTERN DIRECTION
(NOT A PAVEMENT MARION0)
PAVEMENT MARKING
SPEED WBP
VEHICLE OUTLINE FOR
DRIVE -1HRU STACKING
4
STOP 3124 AM
CROSSING 8804
84' 1001E
/
PRGPOSEO
BY OWIENS
6
POLE AND PRE Rousso
cOMMORCIAL
BU)L'DIRO
ZONE. B-2
SO
IIRES
r T
I
CODE COMPLIANCE
CODE
PARKING
ADA PAR'GNO
REQUIRED
1 5PNX / 280 00 FT =18
PROVIDED
24
1 -28 STALLS = 1 ADA spas
GREEN SPACE
208
208
DRIVE -1118U STACKING
4 SPACES
4
25 FT
74.1 FT
SCE (EST)
8 FT
45.8 FT
SIDE (EMI)
5 FT
17.7 FT
REAR
8 FT
40.8 FT
LA BUFFER
FRONT
5 FT
5FT
SIDE (FIST)
8 FT
5 FT
SIDE (Va./
5 FT
0 FT
REAR
8 FT
5FT
AREA HREAKCOWN
ACRES
90 FEET
TOTAL
0.83
27,728
P8M0U5
0.18
8,980
23.738
0.48
21.145
78.278
Ou0S1,0
0.08
3,884
14.308
Vehicular Use
0.37
18,138
88.198
Sidewalk
0.02
1.048
1758
PARKING
4385740 SHOPPING CENTER
43.630 SQ. FT. 281 SPACES, 247840140 10 H.C.
PROPOSED PARKING (REQUIRED)
(41838 SO. FT. - 8.431.87 S0. FT. + 5.804 43. FT.) /250 189 SPACES,
INCLUDING 7 H.C.
Name of Development
LAND USE DATA
DOMING USE
Zoning Pietrkt
Vii' 3.1
:
T.. emd,. ,.,
Na 04 11 .•.. 113010
Er?iII:9l
1 stay
PROPOSED ZONING
Flaad Elevation
FIRM 8893 (Oration 20 TIC 8)
0308F
(8/18/92)
CODE COMPLIANCE
CODE
PARKING
ADA PAR'GNO
REQUIRED
1 5PNX / 280 00 FT =18
PROVIDED
24
1 -28 STALLS = 1 ADA spas
GREEN SPACE
208
208
DRIVE -1118U STACKING
4 SPACES
4
25 FT
74.1 FT
SCE (EST)
8 FT
45.8 FT
SIDE (EMI)
5 FT
17.7 FT
REAR
8 FT
40.8 FT
LA BUFFER
FRONT
5 FT
5FT
SIDE (FIST)
8 FT
5 FT
SIDE (Va./
5 FT
0 FT
REAR
8 FT
5FT
AREA HREAKCOWN
ACRES
90 FEET
TOTAL
0.83
27,728
P8M0U5
0.18
8,980
23.738
0.48
21.145
78.278
Ou0S1,0
0.08
3,884
14.308
Vehicular Use
0.37
18,138
88.198
Sidewalk
0.02
1.048
1758
PARKING
4385740 SHOPPING CENTER
43.630 SQ. FT. 281 SPACES, 247840140 10 H.C.
PROPOSED PARKING (REQUIRED)
(41838 SO. FT. - 8.431.87 S0. FT. + 5.804 43. FT.) /250 189 SPACES,
INCLUDING 7 H.C.
PROPOSED PARKING (PROVIDED) 248 SPACES. INC10DN0 10 H.C. SPACES
LAND USE DATA
DOMING USE
RETAIL (FORMFTLLY A BLOCKBUSTER STORE)
P00110SED USED
3,884 SF FL PROTOTYPE 3 REM ATTACHED
DRIVE -THRU LANES (BA1N)
EXISTING ZONING
8 -2 TRANSUDE BUSINESS
PROPOSED ZONING
3 -2 TRANSUDE BUSINESS
NOTES
1. ROOF TOP 8E31A9CA EQUIPMENT IS TO 0E =REM , PER CITY MOE
2. Al E3£ VAR@® SHOWN ARE IN REFINE. E TO THE BENCHMARK AND MUST BE VOWED
BY THE 0044)4L CHIT ACI03 AT 80.3 REM.
1
3010830 DIMENSIONS SHOWN ON THE CIVIL MEMO= PLANS ARE FOR REFERENCE
PURPOSES CORY. WEN IA1940 OUT THE PROPOSED BUILDING FOUNDATION, THE CONTRACTOR
SHALL USE THE ARCHITECTURAL PLANS FOR EMMT BONNE DOBN90M.
4. SOMME REQUIRES SEPARATE SEWAGE PERMIT.
5. 4341440 LEVELS WLL NOT EMCEED 0.8 FOOT CANDLES ALONG FEWEST. AREA&
LEGAL DESCRIPTION OF SHOPPING CENTER WERE 9UB,ECT PROPERTY IS LOCATED,
(PER OFFICIAL moons BOON 24432. PAGES 4310 -4818,
LOT 5 LESS THE EAST 30 FEET AND ALSO LESS THE NORTH 28 FEET THEREOF, AND LOPS 8 7,
AND B, LESS THE NORTH 25 FEET Of SAME, AND ALSO THAT PART OF LOT 8 NOW MENG USED
AS PUBLIC HIGHWAY MOWN AS FEDERAL 14I0/MAY ALSO MOWN AS &SCAYNE BOULEVARD AND
11105E PARTS OF EACH LO1S 8, 9, 10 AND 11 8)401
IA: BOTH OF FEDERAL RIOHWAY ALSO WNOWN AS BISCAYNE BWLEV ., ALL OF SAID LOTS
BEND 3 ASBURY PAIL ACCORDING TO THE PLAT THEREOF, AS R0... ,,.1' N PLAT BOOK 4.
PAGE 110, OF TIE PUBLIC RECORDS OF 81881 -DACE COUNTY, FLORDA
I Era DESCRIPTION OF SUBJECT PROPERTY AUTHORE0 BY STONER & ASSOCIATES, INC.,
WTHOUT THE 3045FlT OF A TITLE SEARCH A140 BASED ON FOUND PROPERTY CORNERS AND
SHORT VERSION LEGAL DESCRIPTION SHOWN N MIAMI -DADE PROPERTY APPRAISER'S
WEB9TE FOR PROPERTY FOLIO Na 11- 3200 -011 -0080
COMMENCE AT THE SOUTHEAST CORNER OF LOT & ASBURY PAM, ACCORDING TO THE PLAT
THEREOF, AS RECORDED N PLAT BOOK 4, PAGE 110. OF THE PUBIC RECORDS OF MAMA -OAOE
COUNTY, FLORIDA
110340E 90134 8188121 1401, ALONG THE SOUTH LPG: OF SAID ASBURY PLAT AND ALONG THE
NORTH MN�T OF WAY LINE OF 18.E 9018 SLL¢41, A DISTANCE OF 4780 FEET TO 114E POINT O'
THENCE CONTINUE SOUTH 8189'21 WEST, ALONG SAID SOUTH LINE OF SAID ASBURY PLAT MD
ALONG SAID THE NORTH RIGHT OF WAY IDNE OF N.4. 0044 STREET. A 0STAVCE OF 219.07 FEET:
THENCE NORTH 02'34'88' WEST. A DISTANCE OF 1220 FEET 10 71-15 SOUTHEASTERLY 0341 OF
WAY LINE OF BISCAYNE BOULEVARD (STATE ROM Nn 8 - U9. HIGHWAY N. 14
THENCE NORTH 3827108' EAST, ALONG SAD SOUTHEASTERLY RIGHT OF WAY LINE OF BISCAYNE
BOO.VARD (STATE ROM No 8 - U.S. HIGHWAY NO 1), A 301ANCE OF 21083 FEET:
THENCE NORTH 870821' EAST, A DRTAVCE O 8313:
THENCE SOUTH 0289102' EAST, A DISTANCE OF 177.00 FEET TO 110 PONT OF BEGINNING
T3
BBR
6
DATE
01 -04 -2010
PROJECT NO
042701308
SHEET NUMB1R
C-105
1
14 -1/2"
5' -9 5/8"
4' -10"
SPECIFICATIONS:
Open 7 Days
-Cvv
OCT 1
Cabinet
SignComp Aluminum Extrusion / 2 Part 12" Body and Extended Retainer / Parts 1929 & 1940
Faces
3/16" Thick Clear Lexan with 3M 3632 -6513 Dark Green and 3M 3632 -5830 Translucent Light Green
Note: Shield and Bank Text to Illuminate. Background, Stripes and Open 7 Days to be Opaque.
Illumination
Sylvania F48T12/DL/HO
Reveal
Aluminum Fabrication / 1" Height
Cladding
Aluminum Sheet Over Aluminum Angle Inner Frame. / Seam Comers Only
Mounting
Single Steel Upright Support Embedded In Below Grade Concrete Footer/ See Detail Sheet Al -P
Numerals
1/4" Aluminum With Gloss Enamel Finish Pin Mounted to Front Cladding
COLOR SCHEDULE:
Cabinet /Reveal /Cladding
MAP Gloss Acrylic Polyurethane Enamel Paint / Match Pantone 5535 Forest Green
Keyline / All Copy
Negative Cut Vinyl Revealing White Vinyl
Face Background
3M 3632 -6513 Dark Green Vinyl to Be Opaque
Side bar
9
3M 3632 -5830 Light Green Vinyl to Be Opaque
Icon Field / Race Stripe
3M 3632 -5830 Translucent Light Green Vinyl
Numerals
White Gloss Enamel Finish
SQUARE FOOTAGE:
Sign Proposed
1 Freestanding Sign 4.15' x 5.80' =
24.07' at 6' -0" Height Above Grade
Address Proposed
.5' x 1.36' = .68 Sq. Ft.
Total Sq. Footage
24.07 + .68 = 24.75 Sq. Ft.
DOUBLE FACED MONUMENT SIGN ELEVATIONS: 1/2" =1' -0"
�.►.r 11-14-4.
?QTY
atlas
SION INDUSTRIES
FLORIDA 1 GEORGIA
CORPORATE HEADQUARTERS
1077 Wesi Blue Heron Blvd.. Wesi Paler Beach. Florida 33404
P000E: (561)863.6659! 800.772.7932 FAX: (561)863 4294
NORTHEAST DIVISION
707 Commerce Drive, Concord. North Carolina 28025
P000E: (704) 788.3733 J 800.772.7932 FAX: (704) 788.3843
www.altassignindustries.us
SUBJECT TO COM
ITH ALLY/
•`;TA rr AND COI INTY Mil FS AND REGULATIONS
(1)
i
1
UNDERWRITERS
LABORATORIES INC.
LISTED
COA
umauauanarmma
Number
Revision Description
Dale
Approved by
0 APPROVE) 03 WPM
I= APPROVED Aswan
Date fl castECr a maw
Bank
9005 Biscayne Blvd • Miami Shores, FL
Dale
8/30/10
J. Abreu
r
B. Duffer
Dadra No.
A25101
SED
As Shown
Al
Re TD Bank/Miami Shores, FL/9005 Biscayne Blvd.
69 5/8" (5-9 5/8 °)
4
4
v
4
4
4
d
8
4
szo
N
7
-1
1-
ELECTRICAL DATA
Volts
120
Total AMPS
3.41
Circuits
Visible Disconnects
Ballasts
1 ESB 848-46
ELECTRICAL NOTES
1. All materials and fasteners meet 3004.4
2. All electrical components are UL listed and approved.
3. Sign grounded according to NEC 6007.7
4. Signs manufactured and listed NEC 600.3 and marked
per NEC 600.4.
5. A8 branch chculs par NEC 600.5(B).1 or (B).2.
6. All Signs controlled by photocell or time clock par FBC
13-415. (ABC).1.4.
7. One visible 20 amp disconnect per sign per dreg per
NEC 600.6(A).1
36" Dia.
14"
vrr.w.x -I
r
#1929 2 part 12° extruded
alum. double face cabinet
body.
Fasten #1940 retainer to
cabinet body with 3/16°
rivets.
#1940 2 part extended
alum. retainer.
Fasten plates to flat bar and
cabinet body with 3/8" ASTM
A -325 bolts. (4) per plate req'd.
1" x 1" Steel angle vertical
supports welded to plates
at top and bottom of cabinet.
(2) req'd.
Lamp ballast.
UL outdoor rated toggle type
disconnect switch mounted
to side of cabinet.
Fasten plates to cabinet
body with 3/8° ASTM A -325
bolts. (4) per plate req'd.
ASTMA500-B steel support
tube thru cabinet and pole
cover. Weld at steel plates
in cabinet and pole cover.
Customer supplied primary
electrical inside UL conduit
to sign.
Recessed access panel.
Below grade augured
concrete foundation.
Fasten #1955 retainer to
cabinet body with 3/16°
rivets.
Fasten #1944 retainer to
cabinet body #6 countersunk
screws.
#1955 and #1944 2 part
alum. retainer.
1/4" x 1 1/2" alum. fiat bar
welded to cabinet body.
1/8" x 7" x 9 1/2" Steel plate
bolted to 1/4" x 1 1/2" alum.
flat bar welded to cabinet
Weld at plate and support
with 5/32° min. fillet weld on
all four sides.
ca)
L vs Ilk
I
-I-,
r�-
4
`-r
--
'®
14."11
I�
Flat Lexan face with applied
vinyl graphics.
T8 fluorescent lamps.
1/8° x 7" x 9 1/2" Steel plate
bolted to 1/4" x 1 1/2° alum.
flat bar welded to cabinet
Weld at plate and support
with 5/37 min. fillet weld on
all four sides.
1/4° x 1 1/2° alum. flat bar
welded to cabinet body.
#8 x 1/2° Self tapping
TEK screws thru cabinet
and pole cover. (1) every
10» typical.
.080» Brake formed alum.
pole cover.
1/8" x 7° x 9 1/2" Steel plate
bolted to 2" x 2" x 3/16° alum.
angle cross members with (4)
318° ASTM A -325 bolts.
111MM:11W
Code Provisions for Sign Installation
Code Edition: 2007 Florida Building Code, Revised 2009
Wind Load perASCE 7 -05, (Florida Building Code 1609.1.1)
Exposure C
Occupancy Category II: (Table 1 -1)
Importance Factor 1: (Table 6 -1)
Wind Speed 146 (3 sec. gust): (Fig. 6-1B)
TD Bank, Miami Shores, Florida 9116111
Wind Load per ASCE 7 -05 (2007 FBC rev'd. 2009)
V =146 mph (Miami-Dade); 1 = 1.0; Gust Factor, G = 0.85
Supports: 4 "x 4" x 3/16" A500 Gr B steel tubing; Fy = 46 ksi
he = 6.0';hop = 3.0'; hq, +0.05ho = 3.30'
K, = 0.85 (Table 6 -3); (Kz, = 1.0; Kd not applicable)
qh = .00256 x .85 x (146)2 = 46.38 psf
A sign and cover = 6.0 x 5.80 = 34.8 sf;
B/s = 5.8 / 6 = 0.97; s/ho =1.0; Cf 1.46 (Fig. 6 -20)
F = 43.68 x .85 x 1.46 x 34.8 = 2.00 k# (kips)
M= 2.00x3.3x12= 79.2k "#
Sreq = 79.2/ 40.4 = 1.96 in3
4 "x 4 "x 3/16" tube, S = 3.24 in3> 1.96 in3 - OK
Caisson foundation: b = 3' dia; trial D = 4.5'
Soil, sand @ 0.300 k# /sf /f;
S1 = .300 x .34 x 4.5 x 1.33 = 0.61 k# /sf
Per IBC 1805.7.2.1; Equation 18 -1
A = (2.34 x 2.00) / (0.61 x 3) = 2.652
0.5A = 1.281
Dreq = 1.281 {1 + [1 + (4.36 x 3.3) / 2.562]1'2}
Dreg = 1.281 {1 + 2.572 } = 4.58'; 4' -6" OK
Foundation 3' dia x 4' -6" deep
2500# - 28 day concrete; embed tube to 6" from bottom
CONTRACTOR: ATLAS SIGN INDUSTRIES
2290 AVENUE L
WEST PALM BEACH, FL 33404
(561) 863-6659
UC. #ES0000204
ENGINEER INFORMATION
NAME: Theodore M. McAnlis, P.E.
ADDRESS: P.O. Box 14724
North Palm Beach, Florida 33408
E -Mail: ted.mcanlis @hotmail.com
LICENSE No. 19239
As witnessed by my seal, I certify that the
sign structure and foundation meet or
exceed the requirements of the 2009 FBC
for 146 wind load.
"fig/A 9/9/i1
(Elias
SIGN INDUSTRIES
FLORIDA NORTH OAROLINA I GEORGIA
CORPORATE HEADQUARTERS!
1077 West Blue Heron Blvd., West Palm Beach, Florida 33404
PHONE: (561) 863.6659 / 800.772.7932 FAX: (561)863.4294
NORTHEAST DIVISION
707 Commerce Drive, Concord, North Carolina 28025
PHONE: (704) 788.3733 / 800.772.7932 FAX: (704) 788.3843
www. atlassign ndustr res.us
ilk Ali
UNDERWRITERS
LABORATORIES INC.
LISTED
A
Number
• twat Dascrlplion
Approved
O Avwmum as soon
O APPROVED As NOTED
O corer a Rasuawr
9005 Biscayne Blvd • Miami Shores, FL
TD Bank/Miami Shores, FL/9005 Biscayne Blvd.