Loading...
SGN-12-180Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 169514 Permit Number: SGN -2 -12 -180 Scheduled Inspection Date: April 04, 2012 Inspector: Bruhn, Norman Owner: , SHORES SQUARE INVESTMENTS Job Address: 9005 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: ATLAS SIGNS OF LAKE WORTH INC Permit Type: Sign Inspection Type: Final Work Classification: New Phone Number Parcel Number 1132060110060 Phone: (561)863 -6659 Building Department Comments INSTALL 3 DIRECTIONAL SIGNS FOR DRIVE THRU Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments ***PLEASE ASK ARLENE ABOUT THIS*** �G• April 03, 2012 For Inspections please call: (305)762 -4949 Page 5 of 22 ACORDT, CERTIFICATE OF LIABILITY INSURANCE 3 /27 2012Y) 03/27/2012 POLICY NUMBER PRODUCER Slaton Insurance 5713 Corporate Way STE 200 West Palm Beach, FL 33407 POLICY EXPIRATION DATE /MM/DD/YY1 11/11/12 1 -561- 683 -8383 $ 1,000,000 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE INSURED Atlas Sign Industries Atlas Signs of Lake Worth, 1077 W. Blue Heron Blvd. West Palm Beach, FL 33404 1 Inc.; Atlas Realty Holdings, LL INSURER k American Economy INSURERB:Charter Oaks Fire Ina Co INSURER C: North River Insurance Co. INSURERD:The Phoenix Insurance Co. INSURER E. THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR J.18- A TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE fATF (MM/DDM'1 11/11/11 POLICY EXPIRATION DATE /MM/DD/YY1 11/11/12 LIMITS EACH OCCURRENCE $ 1,000,000 GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY 01CI395370 -3 X FIRE DAMAGE (Any one fire) $ 200, 000 CLAIMS MADE E OCCUR MED EXP (Any one person) $ 10,000 PERSONAL &ADV INJURY $ 1,000,000 GENERALAGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPUES PER: PRODUCTS - COMP/OP AGG $ 2,000,000 POLICY ..IIFC:T X LOC B AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS 810 - 184143646 11/11/11 11/11/12 COMBINED SINGLE LIMIT (Ea accident) $ 1,000,000 X BODILY INJURY (Per person) $ X BODILY INJURY (Per acddent) $ X PROPERTY DAMAGE (Per accident) $ GARAGE LIABILITY ANY AUTO AUTO ONLY - EA ACCIDENT $ OTHER THAN EA ACC $ AUTO ONLY: AGG $ C EXCESS LIABILITY 5530928607 11 /11 /11 11/11/12 EACH OCCURRENCE $ 10, 000, 000 X I OCCUR CLAIMS MADE AGGREGATE $ 20, 000, 000 DEDUCTIBLE RETENTION $ 0 $ $ X $ D WORKERS COMPENSATION AND EMPLOYERS' LIABILITY PDTENUB188M619711 11 /11 /11 11/11/12 8 TORY LIMITTS OTH- ER E.L. EACH ACCIDENT $ 1,000,000 E.L: DISEASE - EA EMPLOYEE $ 1,000,000 E.L. DISEASE - POLICY LIMIT $ 1,000,000 A A OTHER Inland Marine Inland Marine 01CI395370 -3 01CI395370 -3 11 /11 /11 11 /11 /11 11/11/12 11/11/12 Sched Equipment $20,479 Rented /Leased Eq $45,000 $ DESCRIPTION OF OPERATIONS /LOCATIONSNEHICLES/EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS CERTIFICATE HOLDER ADDmONAL INSURED; INSURER LETTER: CANCELLATION Miami Shores Village 10050 Northeast 2nd Avenue Miami Shores, FL 33138 USA SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ACORD 25-S (7/97) ATLASS3 • 26248446 ®ACORD CORPORATION 1988 J Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 ^ «„ A „ INSPECTION'S PHONE NUMBER: (305) 762.4949 B DING lu/ PERMIT APPLICATION FBC20 Permit No. LIB Ids)LJ Master Permit No. I o Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): 3/10f2& 5640,1- ftlbt '7f, /1s u. C Phone#: Address: 37 co 13 l /2,1 (0 S 7E !' () City: /II // /'^i State: Fi Tap: 33 /V6' Tenant/Lessee Name: / 1‘10-) k/ /v 4 . Phone#: € -,17-11 4 8 Email• JOB ADDRESS: 90of 13 UcAy1C fJ Lv0 City: Miami Shores County: Miami Dade Zip: 31117 Folio/Parcel #: % J'a DCP " I (cri Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: /i TG 4f Sl dill tiiOtti 7/2 /t j Phone#: at- riff- defy Address: 107 > VII d c on- Ham, Oft C1OD City: 11477 O Avg tS acy state: F6 Qualifier Name: J E (t t? y Ao IN AL ft State Certification or Registration #: 00002 0 N zip: 73 yoi Phone#: Si�/ J73 ` do-1 Certificate of Competency #: Contact P h o n e # : . / - a 6 Y E m a i l Address: d ( N , " . e / { 7 a /1 1 fit, / 7 f . Gil DESIGNER: Architect/Engineer: 7 / //"OPoit E' McAiv f Phone#: kr‘/ 10 !fJ Value of Work for this Permit: $ Z ( l S ear Footage of Work: Type of Work: DAddition OAlteration kiNew ORepair/Replace CUDemolition Description of Work: �ekt.t 3) %Ce c-1-60n j S (C - S *+x+ * ** ******************* ** * * ** x** * ****p **** **+ t,** **+>us **+t,******* * ** *we *e ***x * * *** *** /� Submittal Fee $ Permit Fee $ 'D ) O CCF $ CO /CC $ Scanning Fee $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ Radon Fee $ DBPR $ Bond $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose properly is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days cater the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Si The fo day o who is Owner or Agent nt was ac .' u o'.1ed onally known to me Signature a� r Contra The foregoing ' n was acknowledged before me this 82 day of T- , 20 1'Z --by ARIA.4 s r who has produced who is personally known to me or who has produced identification and who did take an oath. ennui �. .i,� .' e, •'. 415 EXPIRES: April4, 2014 Bonded ThN ---- . —�___ NoteryPubilaUnderwdters as identification and who did take an oath. NOTARY PUBLIC: APPROVED BY /#4 . Plans Examiner My Commission Expires: DUSTY R. SMITH NOTARY PUBLIC STATE OF FLORIDA i i1r1' 'wit* * * * * ** IEavadroe Mgt Structural Review Clerk (Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09) 3 1" 21 11" 1" 3' 1" 2' 11" THE SIGN OF PERFORMANCE '4" DRIVE - TaD THRU ATM F— CORPORATE HEADQUARTERS' ,c77 a1 ueHomaSw.,iwrtP Dock.A.33404 Pkrne: (56 , I (8Q)i72 -7832 Faa (5fi1�863 424+ NORTHEAST DIVISION itriraintift Dr. C NC 211125 P 004)7W4-3733.1P0072-793? F (784)788.3843 1" 1' -6" DIRECTIONAL 1 DIRECTIONAL 2 Drawing No. 142384 Sheet No. (1) OF (1) Date 1,'12/2011 Path FL / Miami Shores PROPOSED SIF DIREC I IONALS SCALE - 1,1_1' -0" 1" 1' -6" 1' -4" 1" 3' 1" 2' 11" Sill 1'-6" -- i SCOPE OF WORK: MANUFACTURE AND INSTALL (3) THREE INTERNALLY ILLUMINATED, SINGLE FACE DIRECTIONAL SIGNS. DESCRIPTION: 1. CABINET = EASTERN METALS 10" EXTRUSION PAINTED PMS 5535 FOREST GREEN 2. POLE COVER = ALUMINUM PAINTED PMS 5535 FOREST GREEN 3. FACES = 3/16" THICK LEXAN WI APPLIED VINYL GRAPHICS. WHITE DIFFUSER VINYL APPLIED SECOND SURFACE 4. ILLUMINATION = H.O. T12 FLUORESCENT LAMPS. COLOR SCHEDULE: CABINET /POLE COVER = MATTHEWS ACRYLIC POLYURETHANE SATIN FINISH / MATCH PMS 5535 FOREST GREEN FACE BACKGROUND = 3M 3632 -6513 TRANSLUCENT DARK GREEN VINYL COPY = SG 308 LEXAN SUBSTRATE W/ 3M 3630 -20 TRANSLUCENT WHITE VINYL OVERLAY DIFFUSER = 3M 3635 -70 WHITE DIFFUSER VINYL • DIRECTIONAL 3 RACESTRIPE = 3M 3632 -5830 TRANSLUCENT LIGHT GREEN VINYL • ••. • • • • . 9005 Biscayne Blvd, Miami Shores, FL S/F Directional Signs • • • '.. • • ••• • • • • • • • ••• • •• 37" A 1" x 1" Alum. angle vertical support fastened to pole - -- cover cladding on inside. 18" .080" Brake formed alum. pole cover cladding. 1/4 "x37/8 "x163 /4 "Alum. mounting plate welded to - inside top of pole cover. See #7 of Sign Specifications and Pole Cover Plate Detail. 1" x 1" Alum. angle (2 1" x 1' Alum. angles vertical support ( g fastened to pole welded to pole cover and cover cladding on to support tube. See #10 inside. of Sign Specifications. 0 B : B POLE COVER (PLAN) 2 1/16" x 2 1/16" Hole II- _ 163/4" �' for 2" x 2" support. 14 3/4" I I '- Holes for 1/4" mounting bolts. (4) Req'd. 8 3/8" COPOLE COVER PLATE DETAIL (PLAN) 1/4" x 3 7/8" x 16 3/4" Alum. mounting plate welded to inside top of pole cover. Rr- 1 1/2" Dia. elec. hole. 158 SIGN ELEVATION : 1 1/2" =1' -0" ELECTRICAL DATA Volts Total AMPS Circuits Visible Disconnects Ballasts 120 arias SIGN INDUSTRIES FLORIDA I NORTH CAROLINA GEORGIA ELECTRICAL NOTES 1. At materials and fasteners meet 3004.4 2. At electrical components are UL listed and approved. 3. Sign grounded according to NEC 60077 4. Signs manufactured and listed NEC 600.3 and marked per NEC 600.4. 5. At branch circuits per NEC 600.5(6).1 or (B).2. 6. At Signs controlled by photocell or time clock per FBC 13 -415. (ABC).1.4. 7. One visible 20 amp disconnect per sign per circuit per NEC 600.6(A),1 CORPORATE HEADQUARTERS 1071 West Blue Heron Blvd., West Palm Beach, Florida 33404 PHONE: (561)863.6659 / 800.772.7932 FAX: (561)863.4294 NORTHEAST DIVISION 707 Commerce Drive, Concord, North Carolina 28025 PHONE: (704) 788.3733 / 800.772.7932 FAX: (704) 788.3843 www.atlassignindustries.us 18" Dia. UNDERWRITERS LABORATORIES INC. LISTED 0 OA : A CABINET SECTION (PLAN) SIGN SPECIFICATIONS : 1. 10" EXTRUDED ALUMINUM SIGN BODY WITH FIXED AND REMOVABLE RETAINERS. 2. FACES OF 3/16" LEXAN SG 308 CLEAR WITH FIRST SURFACE APPLIED 3M TRANSLUCENT VINYL GRAPHICS AND SECOND SURFACE APPLIED 3M 3635 -70 DIFFUSER. 3. (2) F36 T8 H.O. LAMP. 4. (1) 120V / 1.12 AMP BALLAST. 5. (1) UL OUTDOOR RATED TOGGLE TYPE DISCONNECT SWITCH WITH NEOPRENE BOOT MOUNTED TO SIDE OF CABINET. 6. BRAKE FORMED ALUMINUM POLE COVER WITH 1" x 1" ALUMINUM ANGLE VERTICAL SUPPORTS. SEE DETAIL B : B POLE COVER PLAN. 7. 1/4" x 3 7/8" x 8 3/4" MOUNTING PLATE WELDED TO POLE COVER AT INSIDE TOP. SEE POLE COVER PLATE DETAIL. 8. FASTEN CABINET TO POLE COVER WITH 1/4" BOLTS, NUTS AND LOCK WASHERS. 9. 2" x 2" x 1/4" ALUMINUM TUBE SUPPORT THRU CABINET AND POLE COVER WELDED TO POLE COVER PLATE AND TO ALUMINUM ANGLE MOUNTED IN BOTTOM OF POLE COVER. SUPPORT WILL BE EMBEDDED INTO BELOW GRADE FOUNDATION. 10. 1" x 1" x 3/16" ALUMINUM ANGLE WELDED TO BOTTOM OF POLE COVER AND TO SUPPORT TUBE. 11. CUSTOMER SUPPLIED PRIMARY ELECTRICAL INSIDE UL CONDUIT TO SIGN. 12. BELOW GRADE CONCRETE FOUNDATION. TD Bank Directional, Miami Shores, Florida 01/26112 Wind Load per ASCE 7 -05 (2007 FBC rev'd. 2009) V = 146 mph (Miami- Dade); I = 1.0; Gust Factor, G = 0.85 Supports: 2 "x2 "x 1/4" A6061 aluminum Fb (welded). 9 ksi x 1.33m = 12 ksi Sign: hop = 2.25'; Kh = 0.85 (Table 6 -3); (Kz, = 1.0; Kd not applicable) qh = .00256 x .85 x (146)2 = 46.38 psf As1gn= 3.08'x1.5'= 4.62sf; ho =3.0' B/s = 2; s /ho = 0.5; CT = 1.70 (Figure 6 -20) F = 46.38 x .85 x 1.70 x 4.62 = 0.31 k# (kips) Tension on mounting bolts: 1.875" c/c M =0.31 x 0.75 x 12 = 2.79 k"# ft per bolt (2 per side) = 2.79 / 1.875" x 2 = 0.744 k# per bolt A325 (or equal) '/4' bolts; F, = 2.0 k# > 0.744 k# - OK Note: tube extends thru sign extrusion minimizing shear on bolts Cover: Aco,e, = 1.5 x 1.5 = 2.25 sf; B/s = 1.0; s /ho = 0.5; C, = 1.75 FCOV9, = 46.38 x 0.85 x 1.75 x 2.25 = 0.155 k# F55, = 0.155 + 0.310 = 0.465 k# hlne„ = (.155 x 0.75) + (0.31 x 2.25) / 0.465 = 1.75' Sreq= 0.465x1.75x12/12= 0.82in3 2"x 2"x 1/4" al tube, S = (24- 1.54)1(6 x 2) = 0.91 in3 -OK Foundation calculations Caisson foundation in sand or clayey sand: FBC (IBC 1805.7.2.1); Trial depth = 3'; b = 18" dia Soil, sand at 300 # /sf /f (Table 1804.2, sec. 1804.31) S1= .3 x .34 x 3' x 1.33 = 0.407 k#/sf; A, = 2.34F /S1b = (2.34 x 0.465)1(0.407 x 1.5) = 1.782 D = (0.5 x 1.782) {1 + [1 + (4.36 x 1.75 / 1.78212} (Eq. 18 -1) D,eq = 1.78211 + 2.298] = 2.94 "; 3' depth OK Make foundation: 18" dia x 3' -0" deep Use 3000 #, 28 day concrete Embed pipe as shown Code Provisions for Sign Installation Code Edition: 2007 Florida Building Code, Revised 2009 Wind Load per ASCE 7 -05, (Florida Building Code 1609.1.1) Exposure C Occupancy Category II: (Table 1 -1) Importance Factor 1: (Table 6 -1) Wind Speed 146 (3 sec. gust): (Fig. 6-1B) CONTRACTOR: ATLAS SIGN INDUSTRIES 2290 AVENUE L WEST PALM BEACH, FL. 33404 (561) 863-6659 LIC. #ES0000204 ENGINEER INFORMATION NAME: Theodore M. McAnlis, P.E. ADDRESS: P.O. Box 14724 North Palm Beach, Florida 331408 • E -Mail: ted.mcanlis @hotmail.com • •• LICENSE No. 19239 ••• • • •• • ••. As witnessed by my seal, I certify that the sign structure and foundation meet or exceed the requirements of the 2009 FBC for 146 wind load. authorization 2012 This design I engineering is to remain Atlas Sign m 0 Number Revision Description Approved by Date APPROVED AS SHOWN APPROVED AS NOTED CORRECT & RESUBMIT 9005 Biscayne Boulevard, Miami Shores, orida :0114/12 gee`" • J. brow Ma a0er A. Shinn • aY• • D:Rdtthers• 14238 -5 As Shown saet Td Bart�t / Florida / Miami Shores 6 2 5 3 S E 8 U E 5 0 P EXISTING COMMERCIAL BUILDING ZONE: B -2 NOTE: CONTRACTOR TO NOTE NE DIFFERENT BUILDING ORIENTATION SHOWN ON THE 'C' AND 'S' SHEETS (SEE NORTH ARROWS). CONTRACTOR TO CONFIRM BUILDING PLACEMENT PRIOR TO STARTING BUILDING ( FOUNDATION. r PROPOSED SPEED BUMP // 5' REQUIRED LANDSCAPE BUFFER STOP SIGN AND 0 NOT ENTER SIGN 24' WHITE STOPBAR \STOP SIGN AND – PEDESTRIAN h CROSSING SIGN ';. -.24" WHITE STOPBAR PROPOSED MONUMENT SIGN PROPOSED WATER SERVICE 0 20 40 SCALE FEET LEGEND CONCRETE ADA COMPLIANT DETECTABLE WARNING ADA COMPLIANT RAMP TRAFFIC PATTERN DIRECTION (NOT A PAVEMENT MARKING) PAVEMENT MARKING INO VEHICLE OUTLINE FOP r__ - -- DRIVE –THRU STACKING I I PROPOSED CONDfONS Name of Developer 1 TD BANK.NA Address 9050 Atrium Way Mount Laurel NJ 08054 Name of Development TD Bank -9005 Biscayne Bivd Village of Miami Shores Proposed Use Financial Institution.' Bank Zoning District Commercial B -2 TRANSIENT BUSINESS Section, To= •+nshi0. Range 0 -06, T -53, R -42 No. of Stories/ Floors 1 Story Flood Elevation Zone AE ( Elevation 8) FIRM Map: 120 11C 0308F (8/18/92) CODE COMPLIANCE CODE REQUIRED SO. FEET PROVIDED PARKING ADA PARKING 1 SPACE / 250 SQ FT =16 24 1 -25 STAI LS = 1 ADA STALLS 1 GREEN SPACE 20% 0.48 26% DRIVE–THRU STACKING 4 SPACES 0.09 4 SETBACK Vehicular Use 0.37 15,136 FRONT 25 FT 0.02 73.8 FT SIDE (WEST) 5 F1 45.5 FT SIDE (EAST) 5 FT 18.1 FT REAR 5 FT 41 FT LA BUFFER FRONT 5 FT 5 FT SIDE_(ST) 5 FT 5 FT SIDE (WEST) 5 FT 0 FT REAR 5 FT 5 FT AREA BREAKDOWN EXISTING SHOPPING CENTER 43,636 SO.. FT. 261 SPACES, INCLUDING 10 HI.C., ACRES SO. FEET LAND USE DATA TOTAL 0.63 27,728 3,964 SF FL PROTOTYPE 3 REAR ATTACHED DRIVE –THRU LANES (BANK) PERVIOUS 0.15 6.580 23.73% IMPERVIOUS 0.48 21.148 76.27% Buiidina 0.09 3,964 11.30% Vehicular Use 0.37 15,136 58.19% Sidewalk 0.02 1,048 3.78% PARKING EXISTING SHOPPING CENTER 43,636 SO.. FT. 261 SPACES, INCLUDING 10 HI.C., PROPOSED PARKING (REQUIRED) --lll (43,636 SQ. FT. – 6,431.67 SQ. FT. + 3,964 510 . FT.) /250 165 SPACES, INCLUDING 7 H.C. PROPOSED PARKING (PROVIDED) 248 SPACES, INCLUDING 10 H.C. SPACES LAND USE DATA EXISTING USE RETAIL (FORMERLY A 5] OCKBUSTER STORE) PROPOSED USED 3,964 SF FL PROTOTYPE 3 REAR ATTACHED DRIVE –THRU LANES (BANK) EXISTING ZONING 8 - -2 TRANSIENT BUSINESS PROPOSED ZONING 6 -2 TRANSIENT BUSINESS NOTES: 1. ROOF TOP MECHANICAL EQUIPMENT 15 TO BE SCREENED PER CITY CODE. 2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR AT GROUNDBREAK. 3- BUILDING DIMENSIONS SHOWN ON THE CIVIL ENGINEERING PLANS ARE FOR REFERENCE PROPOSED PURPOSES ONLY. WHEN LAYING OUT THE PROPOSED BUILDING FOUNDATION, THE CONTRACTOR SEWER SHALL USE THE ARCHITECTURAL. PLANS FOR EXACT BUILDING DIMENSIONS. BY OTHERS STOP SIGN R1 -1 56'21" W 219.07' (CFT) ' 10' REQUIRED :PARKING SETBACK DO NOT ENTER 5' REQUIRED R5 -1 LANDSCAPE BUFFER STANDARD BOLLARD EXISTING POLE AND POLE MOUNTED TRANSFORMER 1 1 NE 90TH STREET COMMFwl BultANd ZONE: B -2 IST. FIRE HYDRANT 4. SIGNAGE REQUIRES SEPARATE SIGNAGE PERMIT. 5 LIGHTING LEVELS WILL NOT EXCEED 0.5 FOOT CANDLES ALONG RESIDENTIAL. AREAS. LEGAL DESCRIPTION OF SHOPPING CENTER WHERE SUBJECT PROPERTY IS LOCATED: (PER OFFICIAL RECORDS BOOK 24432, PAGES 4515 -4516, M– D.C.R.) LOT 5 LESS THE EAST 30 FEE'. AND ALSO LESS THE NORTH 25 KEET THEREOF, AND LOTS 5, 7. AND 8, LESS THE NORTH 25 FEET OF SAME, AND ALSO THAT PART OF LOT 8 NOW BEING USED AS PUBUC HIGHWAY KNOWN AS FEDERAL HIGHWAY ALSO KNOWN AS BISCAYNE BOULEVARD AND THOSE PARTS OF EACH 10TS 8, 9, 10 AND 11 WHICH LIE SOUTH OF FEDERAL HIGHWAY ALSO KNOWN AS BISCAYNE BOULEVARD, ALL OF SAID LOTS BEING IN ASBURY PARK, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 4, PAGE 110, OF THE PUBLIC RECORDS OF MIAMI –DADE COUNTY, FLORIDA. LEGAL DESCRIPTION OF SUBJECT PROPERTY AUTHORED BY STONER & ASSOCIATES, INC.. WITHOUT THE BENEFIT OF A TITLE SEARCH AND BASED ON FOUND PROPERTY CORNERS AND SHORT VERSION LEGAL DESCRIPTION SHOWN IN MIAMI - -DADE PROPERTY APPRAISER'S WEBSITE FOR PROPERTY FOLIO No. 11 -3206- 011 -0060 ""��""•• ••• t` COMMENCE AT THE SOUTHEAST CORNER OF LOT 5, ASBURY PAL(n ACCORDIIV 7II 11-f� PLA• • • /� - THEREOF, AS RECORDED IN PLAT BOOK 4, PAGE 110, OF THE 7 PKLIC RECDI�S • • MI•DAIM • Q•O • COUNTY, FLORIDA; •• • • • •• • • • • THENCE SOUTH 87 °56'21 WEST, ALONG THE SOUTH LINE OF SAIC1 •kSBUI ' IILAT A • ALONG •tE • •: •• NORTH RIGHT OF WAY LINE OF N.E. 9Dth STREET, A DISTANCE OF 478.01 FEET TI7 THE PUNT 0F• • • BEGINNING; • • THENCE CONTINUE SOUTH 8756'21 WEST, ALONG SAID SG Jj 1N QQF SAID ASBURY PLAT AND ALONG SAID THE NORTH RIGHT OF WAY LINE OF N.E. 90th 5 LEET,: UISTANCj j1F•219.07 FEET; • ^• THENCE NORTH 02'34'55" WEST, A DISTANCE OF 12.20 PIET TO TH SOUTHEAS4RLY:I H•OF •, • • WAY LINE OF BISCAYNE BOULEVARD (STATE ROAD No, 5•+ *S. HI I1VAYRNo. 1. • • • D TE aa • • 0-0- 2010 THENCE NORTH 3627'59" EAST, ALONG SAID SOUTHEASTERLY RICH, OF WAY LSE OF iCAYNE • • BOULEVARD (STATE ROAD No. 5 – U.S. HIGHWAY No. 1), A DISTANCE OF 210.63 FEE • pI20.IICT NO. 041701306 THENCE NORTH 87'56'21" EAST, A DISTANCE OF 85.13'; SHEET NUMBER • • THENCE SOUTH 02'59'02" EAST, A DISTANCE OF 177.00 FEEI•TO T POINT•OFeEGYINII • C -1 Ora • ••• •" •• • • . • • • • • ••• :• ••