RF-12-414Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
t,)2A?
Inspection Number: INSP- 170883 Permit Number: RF- 3- 12-414
Scheduled Inspection Date: March 23, 2012
Inspector: Bruhn, Norman
Owner: SYMES, ALEXIS & STEPHEN
Job Address: 313 NE 92 Street
Miami Shores, FL 33138-
Project: <NONE>
Contractor: RICHMON CONSTRUCTION CORP
Permit Type: Roof
Inspection Type: Final
Work Classification: Hurricane Mitigation
Phone Number
Parcel Number 1132060136360
Phone: 305 -663 -0543
Building Department Comments
REINFORCEMENT OF TRUSSES AS PER HURRICANE
MITIGATION CODE
Inspector Comments
Passa2W ,31 L.
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
March 22, 2012
For Inspections please call: (305)762 -4949
Page 10 of 15
A -1 Engineering Inspection Services, Inc
7066 SW 44m Street Miami, FL 33155
Tel: 786 -398 -9179 Fax: 305- 485 -9011
alroofinspection @gmail.com
LAB CERTIFICATION # 10- 0512.01
Miami, 03/23/2012
To: CITY OF MIAMI SHORE
Re: 313 NE 92 ST
Dear Building Officer:
The following information is additional to the letter dated 3/23/12
Property Address: 313 NE 92 ST
Our office inspected the following specifics:
THE FRAMING IS ANCHORED TO THE CONCRE'T'E TIE BEAM WITH
METAL STRAPS 1" X 16 " X 14 Ga. WITH BLUE SCREWS MANSONRY FASTENERS 2" X 1/4".AND
WOOD SCREWS IN THE OTHER SIDE OF HOUSE AND RENAILED EXISTEN WITH 10 D NAILS
MINIMUN 4 NAILS FOR STRAP
Please do not hesitate to contact my office if you have any questions.
Cordially
//"'
J
REMBEI(O CONTRERAS P.E
P.E # 21522
A -1 ENGINEERING INSPECTION SERVICES INC
CERTIFICATION NO 10- 0512.01
7066 SW 44th Street Miami, FL 33155 Tel: 786 -398 -9179 Fax: 305 -485 -901
Jcb2_ (tclir�
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
Op,
BY:__.. eeme ....eme ® --
BUILDING Permit No. 12—"-- gfc
PERMIT APPLICATION Master Permit N
FBC 20
Permit Type: BUILDING ROOFING
OWNER: Name (Fee Simple Titleholder): 54 ?11-0.) (, s
Address: 3) S iJ O 2" 6 T
Phone #:
City: VI 4 State: ic( Zip:
Tenant/Lessee Name: Phone#:
Email:
JOB ADDRESS:
City:
Folio/Parcel #:
Miami Shores County: Miami Dade Zip:
Is the Building Historically Designated: Yes
NO Flood Zone:
CONTRACTOR: Company Name:
/, c i 1 131 QW+W1 (Q & 1414 e ] ('!d A) CG✓rPhone #:
Address: 7069‘ 5 iv '7 t'' 6 T
City: a r ( Zip: -33
Cit !�'1 • kibn.• State:
Qualifier Name: !` E.114 b•Q VA b < 0 Adv.( F'A J Phone #: 30 S' 6'63 06 9-3
State Certification or Registration #: &c, e 06'6 5'7 @ Certificate of Competency #:
Contact Phone #: Email Address:
DESIGNER: Architect/Engineer: Phone #:
Value of Work for this Permit: $ ,. ? UU Square/Linear Footage of Work:
Type of Work: ❑Addition 6-
Alteration ❑Ne ❑Repair/Replace
•
Description �ta o
scription of Work: ► ' I N(t,e Lr 1 — fvtsS
s4. 19,td 1- - vir\cnt }i1Pttv(t l
T.,
**** *******• x************ *****m ****/***** Fees�x�xa�****+ rx��x ** ** **** *a��x�x�x **** **** **** u�xa� *+��x***
Submittal Fee $ Permit Fee $ / 0o °J CCF $ CO /CC $
Scanning Fee $ Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence o/ such posted notice, the
inspection will not beipproved and a reinspection fee will be charged.
Signature
Contractor
The foregoing instrument was acknowledged before me this 27 The foregoing instrument was acknowledged before me this Z7
day of 4/' 20 J.by , day of aor 20 /4-, by
who is personal] known to me or who has producedgoeW who is personally ' own to me or who has produced /fot i
P.1-1 lice/re As identification and who did take an oath. 2lorA'e/C6--i046-as identification and who did take an oath.
NOTARY
NOTAR C:
Si
Pri
My
****u:****** * ******** * *** *** ***************** *+ x*+ x+ x***** ** ******* *+x***x:***** **** x ********* * *** * * * ** ****u * ***
APPROVED BY
Plans Examiner Zoning
Structural Review Clerk
(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09)
A -1 Engineering Inspection Services, Inc
7066 SW 44m Street Miami, FL 33155
Tel: 786- 326 -9877 Fax: 305- 485 -9011
al roofinspection @gmail.com
LAB CERTIFICATION # 10- 0512.01
To: MIAMI SHORES
Re: TRUSS INSPECTION
313 NE 92 ST
Dear Sirs:
B...........
Contractor: ACCOR ROOFING
A representative from our office inspected the roof framing and roof framing
anchor at above reference location, and we hereby certify that the roof framing
was wood trusses spacing 24" O.C. in good condition and trusses need
anchored to the concrete tie beam with metal straps.. (Minimum numbers of
fasteners per straps shall be 6). All nails shall be clinched and the straps shall
wrap over the roof trusses (See sketch).
This report is based on limited visual review of existing structural
components.
Cordiall
REMBERTO CONTRERAS P.E
P.E # 21522
A -1 ENGINEERING INSPECTION SERVICES INC
CERTIFICATION NO 10- 0512.01
.44 cf--ir.-,a
7066 SW 44th Street Miami, FL 33155 Tel: 786 - 398 -9179 Fax: 786 - 800 -2627
A -1 ENGINEERING INSPECTION SERVICES, INC.
EXISTING- ROOF RAFTER/TRUSSES
WRAP
1 /4 °X 1 1/2° TAPCONS
6-10d NAILS
WRAP STRAP OVER
TRUSSES.
EXIST. GMU WALL
EXIST. CONC. TIE SEAM
DO NOT FORWARD
RICHMOM CONSTRUCTION CORP
REMBERTO CONTRERAS PRES
7066 SW 44 ST
MIAMI FL 33155
SEE OTHER SIDE
LdimihmHdLhdlibihilhIdddingn
ex's°
JEFF ATWATER STATE OF FLORIDA
CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES
DIVISION OF WORKERS' COMPENSATION
* * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW
CONSTRUCTION INDUSTRY EXEMPTION
This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law.
09 -19 -2011
EFFECTIVE DATE: 09/19/2011 EXPIRATION DATE: 09/18/2013
PERSON: CONTRERAS REMBERTO
FEIN: 650378404
BUSINESS NAME AND ADDRESS:
RICHMOM CONSTRUCTION CORP
7086 SW 44TH STREET
MIAMI FL 33155
SCOPES OF BUSINESS OR TRADE:
1— GENERAL CONTRACTOR
IMPORTANT: Pursuant to Chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this
section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt... apply only within the
scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of
election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or
certificate no longer meets the requirements of this section for issuance of a certificate. The department shell revoke a certificate at any time for failure of the person
named on the certificate to meet the requirements of this section.
MC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01 -11
QUESTIONS? (85O) 413 -1609
..269744 -6
.00SI ESS I L TSB
RICHMOM-_ COTRUCT10$' CORP
7066. SW 46--ST
---33155 UNIN DADE COUNTY
*Ili I$ NOT ABILL
OWE
RICHMOM CONSTRUCTION CORP
X196 GENERAL BUILDING CONTRACTOR
n
Nor prow m
n*ESnrrm
WILAMVEM
nnotemammao
ICV CO1RiT 'm
D9/18/2009
09010072001
000075.00.
SEE OTHER SIDE
- tit NOT PAY
RENEWAL
RE rNO.. 303033 -5
STATE# Ct °56590
WORKER /S
1
DO NOT FORWARD
RICHMOM CONSTRUCTION CORP
REMBERTO CONTRERAS PRES
7066 SW 44 ST
MIAMI FL 33155
1f1n1d11Llllihhh,llinhillih d1lllltitltnllti)1M
09 -19 -2011
JEFF ATWATER STATE OF FLORIDA
CHEFFMMSCIALORMER DEPARTMENT OF FINANCIAL SERVICES
DIVISION OF WORKERS' COMPENSATION
* * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW
CONSTRUCTION INDUSTRY EXEMPTION
This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law.
EFFECTIVE DATE: 09/19/2011 EXPIRATION DATE: 09/18/2013
PERSON: CONTRERAS REMBERTO
FEIN: 650378404
BUSINESS NAME AND ADDRESS:
RICIII CONSTRUCTION CORP
7088 SW 44114 STREET
MIAMI FL 33186
SCOPES OF BUSINESS OR TRADE:
1- GENERAL CONTRACTOR
IMPORTANT: Pursuant to Chapter 440 . 05(14 F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this
section may not recover benefits or compensation under this chapter. Pasoan to Chapter 440.00(12f, F.S., Certificates of election to be exempt... apply rely within the
scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.054131, F.S., Notices_ at election to be exempt and certificates of
election to be exempt shall be subject to revocation 0, at any time after the filing of the notice or the immense of the certificate, the person awned on the notice or
certificate eo longer meets the requirements of this section for Wang. of a certificate. The department shell revoke a certificate at any time for failure of the persoe
named on the certificate to greet the requirements of this section.
OWC -252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01 -11
QUESTIONS? (850) 413 -1609
Permit No: 12 -328
Job Name:
March 9, 2012
Miami Shores Viiiage
Building Department
Building Critique Sheet 2nd
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Page 1 of 1
1) This property has an expired permit that must be addressed. Homeowner to call 305
762 -4859.
Plan review is not complete, when all items above are corrected, we will do a complete plan
review.
If any sheets are voided, remove them from the plans and replace with new revised sheets and
include one set of voided sheets in the re- submittal drawings.
Norman Bruhn CBO
305 - 762 -4859
Permit No: 12 -328
Job Name:
March 2, 2012
Miami Shores Viiiage
Building Department
Building Critique Sheet
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Page 1 of 1
1) This property has an expired permit that must be addressed. Homeowner to call 305
762 -4859.
2) Provide roofing mitigation permit for truss /joist strapping by a licensed contractor.
3) Provide poly foam product approval.
Plan review is not complete, when all items above are corrected, we will do a complete plan
review.
If any sheets are voided, remove them from the plans and replace with new revised sheets and
include one set of voided sheets in the re- submittal drawings.
Norman Bruhn CBO
305 - 762 -4859