Loading...
RF-12-227Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 169798 Permit Number: RF -2 -12 -227 Scheduled Inspection Date: March 22, 2012 Inspector: Bruhn, Norman Owner: CACERES, PABLO Job Address: 730 NE 101 Street Miami Shores, FL 33138- Project: <NONE> Contractor: ZARA INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number Parcel Number 1132060172200 Phone: 305 -856 -6123 Building Department Comments TILE TO TILE RE ROOF Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments 21, 2012 For Inspections please call: (305)762 -4949 Page 3 of 13 A -1 Engineering Inspection Services, Inc 7066 SW 44th Street Miami, Fl 33155 Tel: 786-326 -9877 Fax: 305- 485 -9011 a lroofinspection@gmail.com LAB CERTIFICATION # 10- 0512 -01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor ZARA ROOFING Job Address 730 NE 101 ST MIAMI SHORES Owner's Name PABLO CACERES Type of Tile BELL AIR 13" Approximate Roof Height 12 feet Roof Pitch Approximate Square Footage of Roof 21 ft 2 Permit # RF-2-12-227 Date Installed 3/12 Type of access to Roof OK Required Testing Force 35/bs Date Tested 3/20/2012 Number of Tests 52 Testing Eauiament: F.G.E. 100 Contact Name GUSTAVO Phone # 1782_6564-7227 I eIC TCCT ®ACC !I r VICT II Total 52 Tests IN ACCORDANCE WITH THE CRITERIA OF PRL vw TAS 106 TEST HAS BEEN PERFORMED IN FU ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF NATURAL DI Pass 0 Tests 0 Fail L PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS Cordially i REMBERTO CONTRERAS P.E P.E # 21522 A -1 ENGINEERING INSPECTION SERVICES INC CERTIFICATION NO 10- 0512.01 7066 SW 44th Street Miami, Fl 33155 — Telephone (786)326 -9877 — Fax (305)485 -9011 Corner 7 Tests n Pass 0 Tests Fail Perimeter 12 -� Tests `f Pass 0 Tests L Fail Field 24 Tests n Pass 0 Tests Fail �:.9...... Q 'Temie4e. Wi 1E0aeae. 0 °rt. +. ca °e® Total 52 Tests IN ACCORDANCE WITH THE CRITERIA OF PRL vw TAS 106 TEST HAS BEEN PERFORMED IN FU ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF NATURAL DI Pass 0 Tests 0 Fail L PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS Cordially i REMBERTO CONTRERAS P.E P.E # 21522 A -1 ENGINEERING INSPECTION SERVICES INC CERTIFICATION NO 10- 0512.01 7066 SW 44th Street Miami, Fl 33155 — Telephone (786)326 -9877 — Fax (305)485 -9011 A -1 Engineering Inspection Services, Inc 7066 SW 44th Street Miami, Fl 33155 Tel: 786 -326 -9877 Fax: 305 -485 -9011 a1roofinspection@gmail.com LAB CERTIFICATION # 10- 0512 -01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor ZARA ROOFING Permit # RF -2 -12 -227 Job Address 730 NE 101 ST MIAMI SHORES Owner's Name PABLO CACERES Type of Tile BELL AIR 13" Date Installed Approximate Roof Height 12 feet Roof Pitch 3/12 Type of access to Roof OK Required Testing Force 3511s Approximate Square Footage of Roof Date Tested 3/20/2012 Contact Name GUSTAVO 21 ft 2 Number of Tests 52 Phone # (786) 564 -7227 Testing Equipment: F.G.E. 100 SKETCH OF ROOF Revised by 7066 SW 44th Street Miami, Fl 33155 Telephone (786) 326 -9877 — Fax (305) 485 -9011 RE: Permit# RF12 -227 Maori S4 ee Dovetstese 10050 NE 2nd Ave Miami Shores, Fl 33138 Phone 305 - 795 -2204; Fax 305 - 756 -8972 www.miamishoresvillage.com I JORGE ZARAGOZI DATE: 02/17/2012 INSPECTION AFFIDAVIT , licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: CGC 0 0 3 5 6 7 On or about FEBRUARY 17 , 2 012 , I did personally inspect the roof deck nailing and /or (Date & time) secondary water barrier work at 730 NE 101 STREET, MIAMI SHORES , FL 33137-5120 (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigatio ' rofit Manual (Based on 553.844 F.S) Signat State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this 17T Notary Public, Sate of Florida at Large day of FEBRUARY, 2 012 . *co0omtnissi0n` F✓024352 • 385-7 9 *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection NOTICE OF COMMENCEMENT A FORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO 12-2.1. TAX FOLIO NO.11- 32 06- 017 - 22 00 STATE OF FLORIDA COUNTY OF MIAMI-QAOE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement CFN: 20120077708 BOOK 27984 PAGE 4658 DATE:02/03 /2012 08:29:16 AM HARVEY RUVIN, CLERK OF COURT, MIA -DADE CTY Space above reserved for use of recording office 1. Legal description of property and street/address:LOT 3 & E4 OFT LOT 4, BLK 104, AMD PL MIAMI SHORES SEC 4, PB 15, PG 14 730 NE 101 STREET, MIAMI SHORES, FL 33137 -5120 2. Description of Improvement: ROOFING 3. Owners) nerve and address: PABLO D. CACERES & CARLA A. ANZALDI, 730 NE 101 STREET, MIAMI SHORES, FL 33137 -5120 Interest in property: OWNERS, FEE SIMPLE Name and address of fee simple titleholder. SAME AS ABOVE 4. Contractor's name, address and phone number. ZARA INCORPORATED , 420 SW 18 TERRACE MIAMI, FL 33129 -1021 it (305) 285 -1698 6. Surety: (Payment bond required by owner from contractor, H any) Name, address and phone number: Amount of bond $ 6. Lender's name and address: 7. Persons within the Slate of Florida designated by Owner upon wham notices or other documents may be served as provided by Section 113.13(1)(a)7., Florida Statutes, Name, address and phone number: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienur's Notice as provided in Section 713.13(1Xb), Florida Statutes. Name, address and phone number: 9. Expiration date of this Notice of Commencement (the epai salon date Is 1 year from the dated reoordtne unless a dlfletent date is Bpi) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERE IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE F IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE' FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK a OR RECORDING YOUR NOTICE OF COMMENCEMENT. u ° U- r...., Signature(s) of s) or s)' Authorized Officer/Director/Partner /Manager 0 tii Prepared : Lk-P-4 -- Prepared By >- Print Name _ ::E i Prnt Name Z Title/Office k.' LL 1 n e,r Title/Office D STATE OF FLORIDA COUNTY OF MAMI -DADE The instru nt was By b- iiu in Individually, or I3 as for ® CI Personally known, or ® produced the following type of Identification: - J 2� Signature of Notary Public: 1 I'- � z 5 Print Name: r LL GS (SEAL) A ®F-- II = Lug n} m EW % 5 O VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES �vO N Under penalties of peryury, I declare that 1 have read the foregoing and *e .', ; e CamttUSSep # EE 024352 that the facts stated !q it we true, to the best of my knowledge and belief. - teat eptotiswo ,l2 14 .jl' � r� fli4rtrNF��errsw��rn{tB Signature(s) of Ownei(s) or Own r{s)'s Authorized Officer/Director/Partner/Manager Who-signed above: ByX' By ` THIS DOCtE ENT PREPARED BY: JORGE ZARAGOZI 420 SW 18 TERRACE MIAMI, FL 33129 -1021 122.6142 rAtEa 1616 GS BUILDIN PE PLICATION FBC Miami Shores Village Building Department 10050 N.E.2nd Avenue. Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305)762.4949 Permit Type: BUILDING ROOFING Permit No Master Permit No. RECEIVED FEB 2 3 201 BY: RF12 -227 OWNER: Name (Fee Simple Titleholder)rABLO DANIEL CACERES & CARLA ANDREA ANZALDIPhone#: (305) 762-2648 Address: 730 NE 101 STREET City: MIAMI SHORES Tenant/Lessee Name: Phone #: Email: State: FL Zip: 33137 -5120 JOB ADDRESS: 730 NE 101 STREET City: Miami Shores County: Folio/Parcel#: 11- 3206 - 017 -2200 Is the Building Historically Designated: Yes Miami Dade Zip: 33137-5120 NO Ve Flood Zone: 7) '5(04 -- -7274 CONTRACTOR: Company Name: ZARA INCORPORATED Ph #: (305) 799-7507 Address: 420 SW 18 TERRACE City: MIAMI Qualifier Name: JORGE ZARAGOZ I State Certification or Registration #: CGC 0 0 3 5 6 7 State: FL zip: 33129-1021 Phone#: Certificate of Competency #: Contact Phone#: Email Address: zarainc @bel lsouth . net DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 11, 8 0 0 .0 0 Square/Linear Footage of Work: 2 , 10 0 Type of Work: °Addition DAlterution New 2Repair/Replace ODemolition Description of Work: REVISION TO PERMIT RF12 -227 (TILE TO TILE RE- ROOF) CHANGE OF UNDERLAYMENT PRODUCT FROM POLYGASS POLYSTICK NOA 11- 0601.10 TO OWENS'CORNING WEATHERLOCK SPECIALTY TILE &; METAL "UNDERLAYMENT NOA 09- 0908.06 Submittal Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ * Permit Fee $ 3S CCF $ CO/CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ � S/s" QC1 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS. POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law broch " e will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commence ent must be posted at the job site of such posted notice, the for the first inspection which occurs seven (7) days after the building permit is issued. In he settee 46. Signature Sigmature inspection will not be approved and a re' spection fee will be charged. The foregoing instrument was acknowledged before me this 22 day of FEB , 20 12, by CARLA A . ANZALD I , who o an lly known) me or who has produced who is . y kno to me or who has produced o�ntr-r The foregoing instrument was acknowledged before me this 2 2 day of FEB , 2012 , by JORGE ZARAGO Z I , NOTARY UBLI Sign: cam, Print: My Commission Ex As identification and who did take an oath. as id ' 'cation and who did take an oath. qt: ";,V SAMANTI IA MCCANN . Commission # EE 024352 . Expires September 8, 2014 4. Bonded Tin Troy taro Insurance 800. 385.7019 NOTARY PUB Sign: Print: My Commission IC: '° '.,,''' SAMANTHA MCCANN As Commission it EE 024352 Expires September 8, 2014 04 Bonded T ru Troy Fein Insurance 800- 385-7019 ** * *****s **18BrB*********PB did.drd.* .**** atsR.@ rBi.*** *** ** **** * **************0****** **** oRR t+rl** ******* ********** ****** APPROVED BY Structural Review (Revised 07 /10/07)(Revised 06/IO/2009XRevised 3/15/09) Zoning Clerk 11 1/4" RS TC, GALV 6 "OC Q LAPS & 2 ROWS 5 12 OC I 13X3 /26GA /NC) !C EIIVID FEB 25 2512 r m mb 4 ®a ® Q Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roos System Manufacturer: EAGLE ROOF ING PRODUCTS LLC Notice of Acceptance Number: 11-0321.02 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Pmax1: -45.1 Prnax2: -78.6 Pmax3: -116.2 ' -, N Maximum Design Pressure (From the NOA Specific System): 40.4 - - -- -- Method of Tile Attachment: FOAM (MEDIUM PADDY POLYPRO AH16 0 ) Roof Slope: 3 :12 eck Type: Sloped System Description 15/8" CDX PLYWOOD e Underlayment: nsuiatlon: #30 ASTM D226 TYPE II IN /A Fire Barrier: Ridge Ventilation? N/ IN /A Fastener Type & Spacing: dhesive Type: ISELF ADHERING ype Cap Sheet: rENS CORNING WEATHERLOCK CIALTY TILE & METAL UNDERLA oofing Covering: CONCRETE ROOF TILESI Type & Size Drip dge: Mean Roof Height: 11 ' 6" MIAM MADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Owens Corning One Owens CorningParkway Toledo, Ol3 43659 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Weatherlock® Specialty Tile & Metal Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL ofthis NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 08- 0108.05 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI.DADE OUNTY APPROVED NOA No.: 09- 0908.06 Expiration Date: 07/31/12 Approval Date: 02/10/10 Page 1 of 3 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: Roofing Underlayment SBS TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Weatherlock® Specialty Tile & Metal . Underlayment Dimensions 36" x 33.3' rolls 36" x 66.7' rolls EVIDENCE SUBMITTED: Test Agency Underwriters Laboratories, Inc. IRT- Arcon, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Construction Materials Technologies, LLC. Test Product Specification, Description TAS 103 SBS self - adhering asphalt sheet material with a white or green glass re- enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. Test Identifier R14610 02 -012 NEI- 006 -02 -01 NEI- 008 -02 -01 NEI- 045 -02 -01 NEI- 053 -02 -01 APPROVED ASSEMBLIES: Deck Type 1: Deck Description: System E (I): Base Sheet: Membrane: Surfacing: NAM *DADECOUNTY APPROVED Test Name/Report Follow up Service TAS 103 TAS 103 TAS 114 (H) ASTM D 4798 & ASTM G 155 ASTM D 4798 & ASTM G 155 Date 03/28/02 02/28/02 04/01/02 07/30/02 08/08/07 05/01/08 Wood, non - insulated, new construction 15/32" or greater plywood or wood plank Anchor sheet mechanically fastened deck, membrane adhered. One or more plies of ASTM D 266 Type II or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. One or more plies of Weatherlock® Specialty Tile & Metal Underlayment with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with Weatherlock® Specialty Tile & Metal Underlayment is acceptable. Approved for Adhered Roof Tile, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 09- 0908.06 Expiration Date: 07/31/12 Approval Date: 02/10/10 Page 2 of 3 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Weatherlock® Specialty Tile & Metal underlayment shall be installed in strict compliance with applicable Building Code. 3. Weatherlock® Specialty Tile & Metal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. Weatherlock® Specialty Tile & Metal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over roofing Base /Anchor sheet underlayment. 5. Weatherlock® Specialty Tile & Metal underlayment shall not be left exposed as a temporary roof for longer than 90 days of application. 6. The standard maximum roof pitch for Weatherlock® Specialty Tile & Metal underlayment shall be 6:12 when tiles are loaded directly to the Weatherlock® Specialty Tile & Metal underlayment; loading boards or battens are required on roof pitches greater than 6:12 ". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on.roof pitches greater than 6:12 ". 9. Weatherlock® Specialty Tile & Metal underlayment may be used with any approved roof covering Notice of Acceptance listing Weatherlock® Specialty Tile & Metal underlayment as a component part of an assembly in the Notice of Acceptance. If Weatherlock Specialty Tile & Metal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 1a. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock® Specialty Tile & Metal underlayment shall be applied over the underlayment. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. .16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. IAMFDADE COUNTY APPROVED MIAMI•DADE COUNTY APPROVED END OF THIS ACCEPTANCE NOA No.: 09- 0908.06 Expiration Date: 07/31/12 Approval Date: 02/10/10 Page 3 of 3 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAXFOUONO.11- 3206 -017 -2200 STATE OF FLORIDA COUNTY OF MIAMI -)ADE: THE UNDERSIGNED hereby gives notice that improvements wHI be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in thls Notice of Commencement. CFN: 20120077708 BOOK 27984 PAGE 4658 DATE:02/03/2012 08:29:16 AM HARVEY RUVIN, CLERK OF COURT, MIA -DADE CTY Space above reserved for use of recording office 1. Legal description ofpropertyandstreet /address :LOT 3 & E4OFT LOT 4, BLK 104, AMD PL MIAMI SHORES SEC 4, PB 15, PG 14 730 NE 101 STREET, MIAMI SHORES, FL 33137 -5120 2. Description of Improvement ROOFING 3. Owners) name and address: PABLO D. CACERES & CARLA A. ANZALDI, 730 NE 101 STREET, MIAMI SHORES, FL 33137 -5120 Interest In property: OWNERS , FEE SIMPLE Name and address of fee simple titleholder SAME AS ABOVE 4. Contractor's name, address and phone number; ZARA INCORPORATED, 420 SW 18 - TERRACE MIAMI, FL 33129 -1021 / (305) 285 -1698 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(x)7., Florida Statutes, Name, address and phone number. 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Ue non's Notice as provided in Section 713.13(1Xb), Florida Statutes. Name, address and phone number. 9. Expiration date of this Notice of Commencement (the a pIratbn date Is 1 year from the date of remetlIng unless a different date Is specUletly WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of Ontai s) or ner(s)' Authorized CHficer/Diector /Partner/Manager Prepared B ` 1. Prepared By Print Name • MEMINENI ( Pmt Name Title/Office t. 141 n STATE OF FLORIDA COUNTY OF MIAMI -DADE Tine/Office The froing inst rent- ac was know ed before me this 22= day By n/ a Individually, or ❑ as for ❑ Personally known, or ® produced the following type of Identification: Signature of Notary Public: Print Name: GS (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts stated ..4 it are true, to the best of my knowledge and beast. Signature(s) of Owns (s) or Own ARY 2012 14 . , rtim -at PAGE Boas L� S. lk )ps Authorized Officer/Director/Partner/Manager By IANTHA NI.;CANN Commission # EE 024352 Expires September 8, 2014 MeafttelkiaftwasatOMBWM9 above: THIS DOCUMENT PREPARED BY: JORGE ZARAGOZI 420 SW 18 TERRACE MIAMI, FL 33129 -1021 GS Icb 112— tri BUILDING PERMIT APPLICATION FBC 2007 Miami Shores Village Building Department BYe -- — - — 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: BUILDING ROOFING Permit No. Master Permit No. WIE- 2.2,1 OWNER: Name (Fee Simple Titleholder) AaLo DANIEL CACERES & CARLA ANDREA ANzALDIPhone #: (3 0 5) 7 62 - 2 64 8 Address: 730 NE 101 STREET City: MIAMI SHORES Tenant/Lessee Name: Phone #: Email: State: FL Zip: 33137 -5120 JOB ADDRESS: 73 0 NE 101 STREET City: Miami Shores County: Miami Dade Zip: 3 313 7 - 512 0 Folio/Parcel #:11- 3 2 0 6- 017 - 2 2 0 0 Is the Building Historically Designated: Yes NO 1 Flood Zone: CONTRACTOR: Company Name: ZARA INCORPORATED Phone#: (3 0 5) 7 9 9 - 7 5 0 7 Address: 420 SW 18 TERRACE City: MIAMI State: FL Zip: 3 312 9 -10 21 Qualifier Name: JORGE ZARAGOZ I Phone #: State Certification or Registration #: CGC 0 0 3 5 6 7 Certificate of Competency #: Contact Phone#: Email Address: zarain.c@bellsouth.net DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 11, 8 0 0 . 0 0 Square/Linear Footage of Work: Type of Work: °Addition °Alteration °New lilRepair/Replace ;Description of Work: TILE TO TILE RE -ROOF 2,100 °Demolition * * * * * ** * ****** ****** **** *** ********** *Fees*****• ** **aye *are *** * **** **** ** **tun *** **r * *r* J Submittal Fee $ Permit Fee $©t� CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ qa.so TOTAL FEE NOW DUE $ 'e2 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law b chure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of comma: cement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. t e absence of such posted notice, the inspection will not be a. proved and a reinspection fee will be charged. Signature N "t/.tar // er or gent ( ntractor The foregoing instrument was acknowledged before me this 7TH The foregoing instru nt was acknowledged before me this 7TH day of FEBRUARY, 20 12, by CARLA ANDREA ANZALDI , day of FEBRUARY' 20 12, by TOR(" E .ARAGOZT , or who has produced who is (personally known to met or who has produced tification and who did take an oath. Signature who is personally known to me As identification and who did take an oath. NOTA " Y PUBLIC: Sign: Print: My Commission Expires: "' Expires September 8, 2014 Snntlerl " Thry Troy Fain !agorae rinn- 5.7019 Sign: Print: ........ CAnAANTHA MGCANN *s. = Commission # EE 024352 My Commission 33i`r�ar Expires September 8, 2014 �-''•i1j)Iri�''°° Bonded lbw Trey Fe linearangaso 85 .7019 ***** * * ** ** * * * * * * **rA*** *+PAD ■tll ** ** ******+ 3**tr+ A********************* rh*Rr*********** ******** ****** **********rN*** APPROVED BY Plans Examiner Structural Review (Revised 07 /10/07)(Revised 06/I0/2009)(Revised 3/15/09) Zoning Clerk MIAMI -DADE COUNTY TAX COLLECTOR 140 W. FLAGLER ST. 1st FLOOR MIAMI, FL 33130 2011 LOCAL BUSINESS TAX RECEIPT 2012 MIAMI -DADE COUNTY STATE OF FLORIDA EXPIRES SEPT. 30, 2012 MUST BE DISPLAYED AT PLACE OF BUSINESS PURSUANT TO COUNTY CODE CHAPTER BA - ART. 9 & 10 THIS IS NOT A BILL - DO NOT PA RENEWAL FIRST -CLASS U.S. POSTAGE PAID MIAMI, FL PERMIT NO. 231 SU ATION 'VAINER ZARA Sec. T ofBusi 196 GENERAL BUILDING CONTRACTOR THIS IS ONLY : A LtAL BUSII4ESS TAX RECEIPT. DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING LAWS OF THE COUNTY OR CU=ES.- NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS IS NOT A CERTIFICATION OF THE MOLDER'S OUALIFICA- TIONSs PAYMENT RECEIVED !` MIAMI•DADE COUNTY TAX Cf LLEC TOR: 07/12/2011 60020000367 000045.00 ZARA INC JORGE E ZARAGOZI PRES 420 SW 18 TERR MIAMI FL 33129 DATE BATCH NUMBER MOM CERTIFICATE OF LIABILITY INSURANCE I I ATINO.�DAT$ AcOe- 19eopaix- �xeaeo II2lgAtagi2 12,01.pM OF INFORMATION THE CERTIFICATE i;XTBND OR PRODUCER Sisk 8esv3eeb I.LC 14180 intiSi k Besvi 0800 I ne, TS 78254 (B00) 632 -8096 THIS CERTIFICATE IS ISSUED AS A MATTER ONLY AND CONFERS NO RIGHTS UPON HOLDER. THIS CERTIFICATE DOES NOT AMEND, INSURERS AFFORDING COVERAGE Papuan': AM 3. /c /f: SARA, INC. 47.0 S.W. 18TH TERRACE MIAMI. FL 33129 (305) 856 -8123 Fax; 1309) 205 -1698 INSURER A Co 'anion Prooertir end Casualty IntPLAInce C INSURER INSUR6RC INSURER DI INSURER E. THE POLICIES OP INSURANCE LSD BELOW HAVE BEEN RHO 70114E INSURED NA%IRD ABOVE FOR TIM POLICY PERIOD INDIUM. NOTWITHSTANDING ANY NEGUIREMBNI TERM OR CONDTTWM OP ANY CONTRACT OR OTHER DOCUMENT WRN.R'EBPECT TO WHICH THE CERTIFICATE DAT os OWED OR NAY PERTAIN, WE INSURANCE AFFORDED IN re POLICIES CESCRIBED HEREIN I8 SURE= To ALL THE T RMS ®1OWD1=N9 AND OONEITICNE CP SUCH POLICIES, AGGREGATE LOOTS BROWN NAY NAVE BEEN RROUC® BY PAID CLAWS rt1 L TYPE OP RItAIRJWQI POLICY NUMB I (q �0.TJ3YI D )e�—DAZ R I AF1&RAL MANH.RY OOMM&RCAL GENERAL UAUUTY CLANS MADE El OCCUR GAM OCG NEE --� $ 19913okosalAny one Fire) 8 MELD (Any aid1/eme) / PERSONAL a AO% INJURY $ .. elliNINIAl. AGGREGATE E G4N'L AGGREGATE T APPLIES PER I n nL PRODUCTS - COMP/OP AGE $ AUTOMOBILE ~_ ..m LIABILITY ANY AUTO ALL OWNSO AUTOS '>IO H�p.HD AUTOS HIRED AUTOS AWN�OWNED AUTOS COMBINED SINGLE LIMIT (Ee e11 $ BOotty 84JURY ONIM # BODILY INUAY (I'1e mi) S PROPERTY DAWAe6 (Par oxklann Afro OTLY•EAAa3DENT $ $ GARAGE MAMMY R ANY AUTO OTHER THAN BAACO S AUTO ONLY: AGE $ EXCESS LIABILITY OCCUR OpLAeaSMADE 04/07./2012 RACII000 RREN OE S AGGREGATE $ $ DEOUOTI&.B RETENTION 8 # —• $ woRREAB EYIPLOTERB'LIABBJTY OTHER COMPENSATION AND WC77779990901 04/02/2011 A ILL EACHAOOiosEr $ 1000000 EL. moon • E\ BMPI.OYee4S 1000000 s.:.,ml E- PGLIGT U $ 1000000 _ UMR9 S Dgsga{PTpNOFoPBNA1lassAACARD NENBCLESBXCLIISIONSammo sr srmoRsEmenuerlasi PROVM NG 1. �Tahis certfti�ftticaate �'emains in effort, proTided the client's account is in foodd Sages fling with AMG. Applies to ODE Of Ebel for any employe or which the client is not re:etting0S,d0 ee o OMB. employees of AM eaSCd to ZARA, INC., effective 09 11 ,CERTIFICATE HOLDER Am n omm. INSUADEt WORM LETTER MIAMI SNORES VILLAGE 19060 NE 2 AVE MIAMI , FL 33138 CANcELLA_TION SHOULD ANY OPINE ABOVE oaten 9ED POLICES 66 CANES BEFORE DIE EXPIRATION DAZE TNENEOP. IRE RAMS sauna WILL ENDEAVOR TO NAB. 30 DATE WPITTBN NODCE 70 TIECSRRIFlOATE HOLDER NAMED 7011E ,EFT. BUT muss TO 00 SO SNAU. IMPOSC ND OBLIGATION OR LIAmmY oval,/ Rea 'UPON IRE INSURER, nS AGSMs OR MIPESSMITATWS. ACORD 25.5 (7197) AVTRORe'ED REPRIMINTAIrolt ■ A.ACORD CORPORATION 1958 AC�n~ CERTIFICATE OF LIABILITY INSURANCE DA2 /01D,20 -- ._02/01 2012 INFORMATION CERTIFICATE EXTEND OR BELOW. PRODUCER INSURANCE CENTER OF MIAMI -DADE 9901 NW 117 Way Medley, FL 33178 (786) 888 -1215 THIS CERTIFICATE IS ISSUED AS A MATTER OF ONLY AND CONFERS NO RIGHTS UPON THE HOLDER. THIS CERTIFICATE DOES NOT AMEND, ALTER THE COVERAGE AFFORDED BY THE POLICIES INSURERS AFFORDING COVERAGE NAIC# INSURED ZARA ANC 420 SW 18 TERRACE MIAMI, FL 33129 I INSURER GRANADA INSURANCE GROUP X INSURER B: LIABILITY COMMERCIAL GENERAL LIABILITY INSURER C: 12/06/11 INSURER D: EACH OCCURRENCE INSURER IL OVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDMON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. UM �.TR A ADD L IJ RD TYPE OF INSURANCE POLICY NUMBER pp�� EFFE�7�yE DATE(IIRAAlDD/YY1 PQ� YEXPItAiI N LIMITS X GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY GL2007- 759 -01 12/06/11 12/06/12 EACH OCCURRENCE $ 1 , 000, 000 PREMISES ( Tmoureroe) $ 50,000 CLAINSMADE X OCCUR BRED EXP(Any one person) $ 1,000 $ 1, 000, 000 PERSONAL&AD/INJURY GENERAL AGGREGATE $ 1 , 000, 000 GEM. AGGREGATE LIMIT APPLIES PER: POLICY El JECT II LOC PRODUCTS - COMP/OP AGO $ 1 , 000, 000 AUTOMOBILE LIABILITY ANYAUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON- OWNEDAUTOS COMBIBED (Ea ��)SrNGLELIMR $ BODILYINJURY (Per person) $ — BODILYINJURY (Perms) $ PROPERTY DAMAGE (Pereeddent) $ GARAGE LIABILITY ANYAUTO AUTO ONLY- EA ACCIDENT $ OTHER THAN EA ACC $ AUTOONLY: AGG $ EXCESS/UMBRELLA LIABILITY —1 EACH OCCURRENCE $ OCCUR I I CLAIMSMADE DEDUCTIBLE RETENTION $ AGGREGATE $ $ $ 8 WORKERSCOMPENSATIONAND EMPLOYERS LIABILITY ANY PROPRIETORIPARTf$RIBIECUTNE OFFICERIIR EXCLUDED? SPECIAL ROOV IONS below I TOavTLAIMIrB I I ETMR EL EACH ACCIDENT $ EL DISEASE - EA EMPLOYEE $ EL DISEASE - POLICY LIMIT $ OTHER DESCRIPTION OF OPERATIONS/ LOCATIONS /VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT/ SPECIAL PROVISIONS CERTIFICATE HOLDER ELLATION MIAMI SHORES VILLAGE 10050 NE 2 AVENUE MIAMI SHORES, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL— DAYS WRITTEN NOTICE TO THE C o' ' FICATE HOLD • I D TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLI •, ON OR LIABIL) ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. / / AUTHORIZED REPRE' :441 ACORD25(2001/08) @ACORD CORPORATION 1988 PROPOSAL SUBMITTED TO NAME PABLO DANIEL CACERES & CARLA ANDREA ANZALDI STREET 730 NE 101 STREET CITY MIAMI SHORES STATE FL 33137 -5120 TELEPHONE (305) 762 -2648 FAX SCOPE OF WORK 2,100 SO FT TILE ZARA INC. General Contractor Jorge Zaragazi / Qualifier / State General Contractor License Nos. OB0010919 / CGC003587 MIAMI, FLORIDA 305- 285 -1898 • zaralno@bellsouth.net GUSTAVO calk ( 786 ) 564 -7227 PROPOSAL# 1001 - GS - 2012 DATE JANUARY 27, 2012 JOB LOCATION 730 NE 101 STREET ® REROOF 0 NEW ROOF ❑ REPAIR 3 Take oft existing roof down to workable surface, and dispose of debris. ❑ Replace up to lineal feet of roof rotten wood included In contract price. Any sheathing exceeding the allowed amount will be charged $ per lineal foot additional. Fascia to be replaced at $ per lineal foot. Rafter ends to be repaired at $ per lineal foot. 3 Install ONE (1) layer of #30 asphalt saturated base sheet mechanically fastened/loose-laid tB All soil stacks/plumbing pipes protruding through the roof shall receive new covers. N Install new 28724' gauge galvanized metals on overdrips, valleys and gravel stops & metals. ❑ Install new fiberglass shingles, fungus resistant for years, color to be owner's choice. ❑ Install one layer of #90 surface slate set in hot asphalt. N Tile attached: ❑ Mechanically H Foam Adhesive ❑ Mortar ❑ One layer #75/ #43 base sheet ❑ Layers of fiberglass ply felt set In hot asphalt ❑ Install one layer of : O Mineral surface cap sheet O Ruberod/Modfiied top ply ❑ Insulation ❑ Paint aluminum on surface for sun reflection. H ELEVEN (11) year(s) contractor warranty on labor, manufacturer warrants materials. ® ONE LAYER OF SELF - ADHERING POLYSTICK UNDERLAYMENT EI MONIER 13" FLAT TILE SELECTED all material is guaranteed to be specified, and the above work to be performed in accordance to specifications submitted. Work shall be completed in substantial workmanlike manner for the sum of $ 15., 800.00 with payments to be made as follows: $3,000.00 @ acceptance of proposaVcontracd Q start -up and mobilization $3,800.00 (§ tin cap inspection approval TILE PRE -PAID BY OWNER $3,500.00@n #90 dry-In ilspec lonapproval $1, 500.00 go Final Inspection/Approval Job Completion NOTICE TO OWNER YOU THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO THE THIRD BUSINESS DAY AFTER THE DATE OF THE TRANSACTION. SEE ATTACHED NOTE OF CANCELLATION FORM FOR EXPLANATION OF THIS MOM CONTRACTOR MAY HAVE LIEN ENFORCED AGAINST THE PROPERTY. CONTRACTOR WILL USE ESCROW OR POST BOND FOR DOWNPAYMENT, ADVANCES, AND ANY PAYMENT RECEIVED PRIOR TO SUBSTANTIAL COMPLETION OF THE WORK Maeda mevaramem% be core Seethed AB wok In to be caragated in aeertuar ike newer taxably' to steadied practima-any Omelettes ve ilkestwines atoms wit Macias Wows end wit be executed onty upon *Sten work coder from ihe MOW arid We must cosy (Mc %made ead otter necessary busecefertheaboreamk(r ht aksublogation ■awad).We rm provide Public Liabliy+ b eurenc , Yw. Bye awrret,.ttbe respenaeis rot Wiens] espenses ter may wearer *news In case riktiganimer disease oar eny aped clads aon&@at ACCEPTANCE OF PROPOSAL r, the owner, undetatatd that upon endmsemad by Connector. the proposal ad be conskimed eocepted and become bkatingco Contractor and Chimer ender timbals and agreements ea outlined in the propenut I consider the atom prides. Stectficaborra and co dSnen satisfactory, I hereby accent the pry. Yeu, the Cer hmteh area owlzed 1 de the 'mikes apedfod. Peyment eat be made es outlined ehoe Ad amounts well accrue 11% interest per Montt Owner's See: and oarniti ns must be eppeened by VOW4/ D 10050 NE 2nd Ave * Miami Shores, Fl 33138 Phone 305 - 795 -2204; Fax 305 - 756 -8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Date: 01/27/2012 Re: Owner's Name: PABLO DANIEL CACERES & CARLA ANDREA ANZALDI Property Address: 7 3 0 NE 101 STREET , MIAMI SHORES , FL 3 313 7 - 512 0 Roofing Permit Number: Dear Building Official: connections of my building becau f The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) certify that I am not required to retrofit the roof to wall Signature State of Florida County of Dade CA-(2._c_4 ,M Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this 27TH "" SAMANTHA M CMNN r 'IA Commission # EE 024352 f. Notary Public, Sate of Florida at Large �'. `=` Expires September A.2014 * When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300, i $ 0.00, and the buil • mg was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Property Information Map 1 of l http: / /gisims2.co. miami - dade. fl. us / myhome /printmap.asp ?mapurl =http: / /g... My Home Miami -Dade County, Florida Property Information Map Aerial Photography - 2009 This map was created on 1/26/2012 9:25:31 PM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. 0 LESS THAN $300,000.00 7ft Summary Details: Folio No.: 11- 3206 - 017 -2200 Pro.ert • 30 NE 101 ST iling PABLO D CACERES & CARLA dress: ANZALDI 730 NE 101 ST MIAMI FL 33137 -5120 Property Information: Primary Zone: 1100 SINGLE FAMILY RESIDENCE CLUC: 0001 RESIDENTIAL- SINGLE FAMILY Beds /Baths: 13/2 'Floors: iving Units: 1 1 kJ S. Foota. e: Lot Size: 12,127 • 270 SQ FT ear Built: 1955 • D PL MIAMI SHORES EC 4 LOT 3 & E4OFT LOT 4 PB 15 -14 BLK 104 Legal Description: LOT SIZE 90.000 X 103 • R 10858 -1275 0880 1 OC 24709 -3538 06 2006 Assessment Information: ear: and Value: Buildin• Value: Market Value: sessed \blue: 2011 $115,180 $162,958 164,046 $278,138 308,217', 18,138 308,217 2010 Exemption nformation: Year: I 2011 I 2010 Homestead: I $25, 000 $25,000 2nd Homestead. I YES YES Taxable Value Information: ear: 2 2011 2 2010 axing A Applied A Applied thority: E Exemption/ E Exemption/ ' e• Tonal: + +• 50,000/$228,138 ' '.50,000/$258,217 ounty• * *50, 000 /$228,138$50,000 /$258,217' ity:, 5 50 ,000/$228,138I$50,000/$258,217 chool „ „25 000/$253,13825,000 /$283,217 ((Board: Sale Information: ale Date: 42006 ale Amount: x,700,000 ale O /R: 24709 -3538 ales ualification ales which are qualified Description: View Additional Sales 1/26/2012 9:26 PM View Additional Sales 1/26/2012 9:26 PM Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section Section A (General Information) Master Permit No. Process No. Contractor's Name ZARA INCORPORATED Job Address 730 NE 101 STREET ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile Lag Mortar Ad.* ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood hi ,g ❑ Prescriptive BUR -RAS 150 ROOF TYPE El New Roof XI Re- Roofing ❑ Recovering ❑ Repair ❑ Maintebanbe ,It .0 600 ega067.11a. ROOF SYSTEM INFORMATION Low. Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) - 0 - 2,100 2 , 10 0 --- NO MECHANICAL WORK ve S t Tile s /Sh kes NO GAS STACKS Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ■uuuu. uu.u. ■.uuuumuu■NNINuuu.umNE■NE: L1....... ■ ■..■ ■ ....uuuu u..MMI.■ ■.!!l.... ■ ■■!uu mu uMM■■ ■!.■■.!■■■...■■ ■■ ...NIM.. ■■uuuuuuuuuuuu■ ■■ ..lEN.■ ■■■uuuuuuu•muuu mu •u■■!!! ■!■...!uuummu■■ mu uuuruu t ■ ■!! ■ ■.!!.!. ■■ ■l ...NNEN ■uu•uuu■! ■t.■■■ ■■ ■■._.. ■■■■uuuuuu■u•uu POPENNNOMMEMNE ..■!■.!!■■...;I A CASIMMEMMMENNE •uuumu ■.l... =L4 iiA6MNIMIMMEEMMIEN •.mu.uuuu...!.■ mu NONNIMME ■!!!.!■■■■!.!■■ ■! !!.N■. ■uu..u.!!..■.!■ ■ ■r MEN NE= ■ ■ ■■uuuuuuuuumu ■■. ...NNE. ■uuu•uu■!..■■!■ ■u MENEM ■l...... ■■!.■.■ ■.■'!.!EN!. uuuuuu■uuuuuuuu NM MEN.. ■■uuuuuu...l..■ .. ■■._.! ■uu•uuu...l.!!■ ME NOMMuu ■■uuu.um.l..!!■ mu uuuENuu ■.....l...■.!.! ■m MEN EM KOMMENNEEMMOANN FLAT NO RE — ROOF mu uu•�uu !..l...l..!!.!. ......■muuuuu!. ■l ...EM ...■..uumuuu..! ■u MNIMMINEN N■■....■...!■.■ ■. ...NN■■ ■...!!.l...!!!■ ■. !..NNuu ■..!!!!uuumuu.. ■■ _ MENNE ■....■.....!!.. ■u ..0 u. ■....■.!.!.!!!! mu uuuEM .uuuuuu........ II IIiiII ....!l......l.! ..!l..m....l... ■■NNOINN■■■NN■■ ■....■ ■.uuuuumu ■u MEN EM .!!!!! ■!!..l.!■ ■m MEN EM ..!!!!!l....■■! ■■ ■.l.1!■ ..!!.l....■■■.■ ■■ mum_u. .. .l.NN.. Boo GS Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: EAGLE ROOFING PRODUCTS LLC Notice of Acceptance Number: 11- 0321.02 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Pmax1: - 4 5 . 1 Pmax2: - 7 8. 6 Pmax3: -116 .2 Maximum Design Pressure (From the NOA Specific System): 40.4 Method of Tile Attachment FOAM (MEDIUM PADDY POLYPRO AH16 0 ) Roof Slope: ' 3 :12 eck Type: Sloped System Description 5/8" CDX PLYWOOD Type Underlayment: nsulation: #30 ASTM D226 TYPE II IN /A Fire Barrier: Ridge Ventilation? N/ IN /A Fastener Type & Spacing: dhesive Type: Mean Roof Height 11 ' 6" 1 1/4" RS TC, GALV 6 "OC Q LAPS & 2 ROWS Q 12 OC SELF ADHERING Type Cap Sheet IPOLYSTICK UNDERLAYMENT} oofing Covering: BEL AIR 13 " FLAT I CONfl RPE ROOF PTT RSl. Type & Size Drip dge: 3 X 3 / 26 GA / NC Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment -based tile systems, choose either Method 1 or 2. Compared the values for Mr with the values from Mr If the M, values are greater than or equal to the M, values for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment -Based Tile Calculations Per RAS 127" (P1; 45.1 x,l 0.278 = 12.54) -Mg: 7.71 =Mt1 4.83 NOA Mr 40.4 . (P2: 7s.6x a, 0.278 = 27.85) -Mg: 7.71 =ma 14.14 NOA Mr 40.4 (P3:- 116.2x A 0.278= 32.31) -Mg: 7.71= Ma 24.60 NOA M, 40.4 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below NOA Mr • Mr Required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment -based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift-based tile systems use Method 3. Compared the values for F1 with the values for Fr. If the P values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift-Based Tile Calculations Per RAS 127" (P1:_ x l: = x w: = - W:_ x cos 8: = Ff1: NOA F1 _ _,. _._) (P2:___ xl: =_xw: =_)- W:_xcos 0: =Fa: NOAF1 _ (P3:____ xl: =_xw:= W:_.,xcos 0: =Fa: NOAF1 _ _)- Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope a Job Site Aerodynamic Multiplier d NOA Restoring Moment due to Gravity NIA NOA Attachment Resistance M, NOA Required Moment Resistance M Calculated Minimum Attachment Resistance F1 NOA Required Uplift Resistance F, Calculated Average Tile Weight w NOA Tile Dimensions I = length w = width NOA All calculations must be submitted to the Bu (ding Official at the time of permit application. SECTION R440213 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics-Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. F3 C Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. (1.7-9-(4- Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. �3 L Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. U , _ Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Ventilation: Most roof structures should have some - .'lity vent natural airflow through the interior of the structure assembly (the building itself). The existing of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which ; It in extending the service life of the Owner /Agent's ,Si,! (attire Date Revised on 7/9/2009 ID Date H IAMI. COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.Eov/building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA # 09- 0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Sub - Category: Material: Roofing Underlayment SBS , APP Self - Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Facer of Membrane with surface printing) Manufacturing Location #1 & #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3' 3318" Or 65' x 3' 80 mils thick Roll: 32'10" x 3' 33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non - wicking fabric surfaced, self - adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass -fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self - adhering, glass- fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 2 of 8 PRODUCTS DESCRIPTION: Product Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 61' x 3' 33/8" 60 mils thick MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Aaencv, Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Specification ASTM D 1970 Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P36900.09.11 PRI01111 PUSA - 005 -02 -01 PUSA - 018 -02 -01 PUSA- 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA - 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Product Description A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane, specific for use as a high temperature underlayment. Designed as a metal roofing. Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 09/01/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 -Y2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. 1R-Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct-to-deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4 "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Browning may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 8 of 8 M1AMI13: COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/buildine/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro A1I160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMHDADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05 /10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® Al-1160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using PolyproiD All 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Polypro AH160 Foampro RTF1000 ProPack® 30 & 100 Dimensions Test Product Description Specifications N/A TAS 101 Two component polyurethane foam adhesive N/A Dispensing Equipment N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbsfft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Fe 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAM•DADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05 /10/12 Approval Date: 04/14/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test NameIRenort Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANOI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. (IF) W 2 F'— MS MIAMIDADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro +? AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance' with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro +_? dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPackl 30 & 100 dispensing equipment only. 7. Polypro AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polyproo AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro n AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nall through plastic cement Paddy (Beneath Tile) 772ave course only: 4 ht. up from weephom Keep adhesive sem& Fascia Nall through plastic cement Underlaymant Optional 2o4s tor I) Place enough adhesive to achieve if to 23 steep pitch applications square inches In cadent with the pan the 2)Turn covers upside down. Place adhesive 112 In. To tin. From outside edge of cover tile. Than Install the tile. Underlayment Ng through plastic cement NIAMIDADE COUNTY APPROVED Nem lop porno otthe cave COUTO Me Abut to second course of pan tiles, Ensure cave end of pan red cover thee are flush et cave line. Eave closure Weephole Fascia (ntortar shown) Optional Potato Nadir on !papaw' edges of file NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 5 of 7 Nell through plastic cement ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement Paddy (Beneath Tile) MIAMI•DADE CO NTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 6 of 7 • ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy (between tile) Paddy (under tile) x3 n. Single paddy on under - layment Single paddy under tile Single paddy on top of file course In. X7ln. medium size paddy eave Fascia course only Nall through plastic cement Nail through plastic cement Single paddy under tile Underlayment Single paddy between tile 21n. x 7In. medium size paddy eava ` �►+ course only !in.x3ln. Single 41n. paddy on under - layment Single paddy on top of the Eve Course Fascia Weephele Eave closure Drip edge Single paddy between tile PAIn.x 3 In. Single paddy on underlayment Single paddy on top of the Ewe Course Eave Closure 21n. x 7 in. medium size paddy ease course only Fascia END OF THIS ACCEPTANCE MIAM1 DARE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7 MIAMIdaAD>` COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami. Florida 33175 -2474 T (786) 315 -2590 F (786) 315-2599 wwnv.miamidade.aov /building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bel Air, Bel Mr Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle Low Profile Concrete Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07- 1018.08 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No. :11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Cateaorv: Sub Cateaorv: Material: Roofing Roofing Tiles Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Bel Air Concrete Tile Bel Air Double Eagle Concrete Tile Ponderosa Concrete Tile Ponderosa Double Eagle Concrete Tile Golden Eagle Concrete Tile Trim Pieces Dimensions L = 17" W =12'/" Thickness = %" L = 17" W =12%" Thickness ='A" L= 17" W =12'/" Thickness =' /a" L = 17" W =12'/" Thickness =' /z" L = 17" W= 12'/" Thickness =' /z" 1= varies w = varies varying thickness Test Product Specifications Description TAS 112 Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. TAS 112 Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail -on applications. TAS 112 Flat profile concrete roof tile with slate finish equipped with two nail holes. For adhesive set, direct deck or battened nail - on applications. TAS 112 Flat profile concrete roof tile with shake finish equipped with two nail holes. For adhesive set, direct deck or battened nail - on applications. TAS 112 Flat profile concrete roof tile brushed finish equipped with two nail holes. For adhesive set, direct deck or battened nail - on applications. TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No. :11- 0321.02 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 2 of 9 2.1 EVIDENCE SUBNIITTED: Test Agency Test Identifier PRI Asphalt Technologies ERPF - 001 -02 -01 Redland Technologies 7161 -03 Appendix III 7161 -03 Appendix III❑ 7161 -03 Appendix II P0402 Redland Technologies Redland Technologies iRedland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied 'Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. , Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. MIAMI E COUNTY APPROVED Letter Dated Aug. 1, 1994 P09647 -01 94 -084 25- 7094 -(2, 5, & 8) 25- 7183 -(5 thru 6) 25- 7214 -(1, 5 , & 8) 25- 7487 -2 25- 7496 -(1 & 4) 25- 7804 -6 520109 -1 520111 -4 520191 -1 Calculations Calculations Test Name/Renort TAS 112 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier Restoring Moments Due to Gravity Date Aug. 2006 Dec. 1991 Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 Aug. 1994 May 1994 Oct. 1994 Feb. 1995 March, 1995 Dec. 1995 Dec. 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 Sep. 2006 NOA No.:11- 0321.02 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 3 of 9 1< 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless .stated -otherwise by the underlayment materiaririanufacturers published literature. - 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - A ft3 Tile Profile A (ft3) Batten Application A (ft ) Direct Deck Application Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 0.301 0.278 MIAMIOADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 4 of 9 Table 3: Restoring Moments due to Gravity - Ma (ft-Ibf) Tile 3 ":12" 4 ":12" 5 ":12" 6 ":12" Greater than Profile 30.9 38.1 17.2 7 " :12" Bel Air, Bel Batten Direct Battens Direct Battens Direct Batten Direct Batten Direct Air Double s Deck 2 #8 Screw Deck 51.7 Deck s Deck s Deck Eagle, 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07 Ponderosa, 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 50.3 65.5 Golden 1. Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. Eagle, Ponderosa Double Eagle Flat • - Tile Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Bel Air, Bel Air Double Eagle, Ponderosa , Golden Eagle, Ponderosa Double Eagle Flat Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails • 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 50.3 65.5 48.3 1. Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 5 of 9 Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Adhesives 31.33 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. odu Polyfoam Prct, Inc. Average weight per patty B grams. Table 6: Attacht nentResistance for Single Patin Expressed'as a Moment - Mi (ft= lbfr.. . .. Adhesive Set Systems Tile Profile Tile Application Minimum Attachment. Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile PolyProTM 118.94 PalyProTM 1 40.4a 3 Lar • e • add • lacement of 45 • rams of Pol Prom. !4 Medium paddy placement of 24 !rams of PolyProTM' Table 7: Attachment Resistance Expressed as a Moment - Mi (ft -Ibf) for Mortar or Adhesive,,Sat Systems.. : Tile Profile Tile Application Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Mortar Sete 43.9 5 Tile -Tite Roof Tile Mortar. 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or Iogo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". �vrr e FLORIDA MIAMWADE COUNTY APPROVED NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 6 of 9 BEL AIR, BEL AIR DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) NOA No.:11- 0321.02 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 7 of 9 • 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING BEL Am BEL AIR DOUBLE EAGLE NOA No.:11- 0321.02 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 8 of 9 a t PONDEROSA PONDEROSA DOUBLE EAGLE NOA No.:11- 0321.02 Expiration Date: 10 /05/16 Approval Date: 05/12/11 Page 9 of 9 GOLDEN EAGLE END OF THIS ACCEPTANCE MIAMbDADE COUNTY APPROVED NOA No.:11- 0321..02 Expiration Date: 10/05/I6 Approval Date: 05/12/11 Page 10 of 9