Loading...
RF-12-213r 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 171629 Permit Number: RF -2 -12 -213 Scheduled Inspection Date: March 30, 2012 Inspector: Rodriguez, Jorge Owner: THOMPSON, MICHAEL Job Address: 1420 NE 103 Street Miami Shores, FL Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number Parcel Number 1132050310030 Phone: 305 - 757 -2612 Building Department Comments RE -ROOF TILE AND FLAT Passed --1M Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 169704. lJiEg1.1.0°7.-- `d, . March 30, 2012 For Inspections please call: (305)762 -4949 Page 11 of 11 F.I.E, j• FLORIDA INTERNATIONAL ENGINEERING &TESTING LAB INSIGHT •INNOVATION •INTEGRATION Florida International Engineering and Testing Lab LLC 16701 SW 117 Avenue, Miami, FL 33177 Telephone: (305) 378 - 1991 -Fax: (305) 378 -1997 Miami -Dade Lab Certification # 07- 0612.11 -State of Florida ca #27273 �SITE SPECIFIC INFORMATION Owner's Name: t 4 l O M ' 1� Job Address: 14 4�111 D Roofing Contractor: y-1-4 O V'', 1ZO ®E t Permit Number: R.'"Z` 12.• 213 Type of Tile: Approximate Roof Height: 12 feet Slope: / • 17— Type of Access to Roof: i Ladder OtherRequired Testing Force: 35 lbs. Date Installed: 3 • ' 11 Approximate Square Footage: 31200 ft2 Testing Equipment: F.G.E. 100x Shimpo Instrument -[ Date of Inspection: 3 • 2 ' tZ TEST RESULTS P= PASS, F= FAIL Test Location P or F Test Location P or F Test Location P or F Test Location P or F Test Location P or F 1 `fd.9S 21 FAr44 41 e,0,4y 61 81 2 22 42 62 82 3 23 43 63 83 4 24 44 64 84 5 25 45 65 85 6 26 46 66 86 7 27 47 67 87 8 28 48 68 88 9 29 49 69 89 10 30 50 70 90 11 31 51 71 91 12 32 52 72 92 13 33 53 73 93 14 34 54 74 94 15 35 55 75 95 16 36 56 76 96 17 37 57 77 97 18 38 58 r 78 98 19 39 59 79 99 20 40 60 80 100 J ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST ADDITIONAL TEST INFORMATION Perimeter Width: 1 ft Area Units or ft2 No. of Tests Perimeter 1 , s oo 15 Field is 2 so 12. Corners 15 15 Hips & Ridges 4e 3o b RESPECTFULLY SUBMITTED BY: Job Address; Contractor Other. Sketch of Roof FLORIDA INTERNATIONAL ENGINEERING & TESTING LAB, LLC k2 v - tQ 3 'S-( N` .640.14 . V t, t-)-4 iiiiiMiiiiiiiiiiii ■ ■iiiii iisiOi■EMEM iiiiiiiiiii ii iiiiiiiiiiiiMEiiiiiiiiii■ II. iiiiii iiiii ■iiiiiiiiiiiiiiiiiiiiiiiii ■ iiiiiii» iiiiiiiiiIUiiiiiiiUIiiiiiiii■ isiiiiiiiiisiiiiiiiiiEiiiiiiiiiiiMiiii ■/ iiiiiiiiiiiiiiiiiiiii ■iiiiiiiiiiiiiii■ iiiiiiiiiiiii t■SiiiitiiiisESiiiiitliiiii ■iiiiiiiiiiiiiiiiiiii■■i / iiiiiiiiiiiii■ ■ iiiiiiiiiiME ®iiiiiiiiiiiiiiiiiiiiiiiii■ ■ iiiMiiiiiiiiiiiiiiiiiO %iiiiiiiiiiiiiiii MOMMINIMMINIffemmummummummEMMEMEMEMMEM ■ iiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii■ ■iiiiiii /ii>u iiilMii■Ai,iiiii> ■i/iiiiii■ iiiiiiiiiiiiOMMME Z[lNi/iiiiiiiiiiiiiiiii■ ii/ iiiii !//iiiiiiRiiiiiiiiiiiMiiiiMiiIN ■itiiiiiammumm irFra iii/iio rriiuiiu`';ftl■ ■ iiiiiiiuiii ■aiiiiuUiiiiiii ■aQii?Iiiii l■ ■ii!!eiiii:= !eii■/liiiiiuiiii mmiiiriii1i ■iii r7iiiitiAl'm"eriiiiiimiiiim!Si tammomm is iii• iiiiim. ii aNL iiiiiitkaiiu -:,iii mumeiil■ ■iii iiirOriiMPUMI !!ii[L7iiiP\iNW1RIMIUMOMM iii •liiAiiiiiiL//Iiiiitii�iii.�.: ME�..��ii immarRimmtanumminummumminnutommiumgmim mriL.iiiiiliiJ iivar lom i iii ss % misiiiii Tit i•iiiir` iii mu Ifs`.iil i/uviii►ljimmarmimmu irmumm/ ri /!'Jii■ MINIM I UMMS MPMMILIAMl /iii[a!iiiIUULU % /EUIII ■UUI'iliiiiiWiiiiiiii ii*i ■/R i'liiitXil ■M IIMMOICIAIMMEMUMMIMIMMAIMAIMNAmmammummEN ■fiiiii - - -i =a iiiiii-- L■ii -!■ - ,iiiiiiiG.� ■ iiiiis tiiti %iiRS/iiEiiiIMME /i /iitiiiri ■iiiiii iiiiiitMtiiEROM O MM I i ii Mi iiiiiii Cgiiiiiii- - w i11: -1 i_/i miiiiiiiiiisiiiiiiiiimmaiiiiiiini iiiiiriii ■iiiiiiii■iiiiMiii ■iiiiiiiiMi■ ■ iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiriiii ■ ■NiiiiiEMiiiiINIiiiiiiiiiii■iiiii ■iiiiiii Notes BUILDING 11/ tit PERMIT APPLICATION xsC 20 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: BUILDING OWNER: Name (Fee Simple Titleholder): Address: /lid ® A) r REtE1VED Permit No. C Master Permit No. ROOFING /o MSc I �iomP.saN City: IV l c)l ofz ) Tenant/Lessee Name: State: Phone #: le ‘7•• Zip: 33 la Phone#: Email: JOB ADDRESS: / /'d IX / ®3 i City: Miami Shores County: Folio/Parcel#: //.° 3206 CP 3 % ¢ ®30 Is the Building Historically Designated: Yes NO Miami Dade Zip: 33/30 Flood Zone: CONTRACTOR: Company Name: ®bervoU. % Address: / 5 9 vr q 7 Phone #: 3O.1' 14'�/ City: ' rs State: Qualifier Name: .."2 CiAttc p 7)44,701,4f- State Certification or Registration #: eee 0 %' 3 04 Certificate of Competency #: Contact Phone#: 3 0S- )57 - .240/L. Email Address: a/JZII%%OU/i- ty£ e t - CO f11 DESIGNER: Architect/Engineer: Ph'ine#: Zip: 3.2 I Phone#: OF- 7' ? 'aaf L Value of Work for this Permit: $ 0'e j 144- ' ®" Square/Linear Footage of Work: Type of Work: ❑Addition ❑Alteration ❑New epair4 eplace Description of Work: ' L _ t ! ,, J k/ . � % ❑Demolition * * ** ****** **** *** **+ x******m******** **** Fees*** **********+ x*+ x+ x****** ** *********** **** * *** Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ `0 l.J! •5(0 i bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT.ECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. I the absence of such posted notice, the inspection will not be approved tend a reinspection fee will be charged. Signature Owne r A ent The foregoing instrument was acknow °ledgedd before me this 3'® day of ! , 20 by Kat (fl oMpuiU , who is personally known to me or who has produced •��� As identification and who did take an oath. NOTARY PUBLIC: Sign. Print: sA My Commission Expire PA; h "i'ic i 1..)3I .Sarag D. Fidtl-i l t ]086755 02 13 kkkkkkkkk kkkkNkkkkkkk*** Np FK l k kk****kkkkNkkkqN*k*** *NkNk*** Contractor The egoing instrument was acknowledged before me this _. day of 4'I -- , 20 11, by J&fPtk( L%- 0400,040- who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: 54-if%Pli- D T.C- STATE (i MY' d.1a 11 Hart II DI)3b7599 f;, X13 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 07 /10/07)(Revised 06 /10/2009)(Revised 3/15/09) CUMULATIVE SUBSTANTIAL IMPROVEMENT VERIFICATION WORK SHEET In accordance with FEMA regulation and Miami Shores Village Flood Damage Prevention Ordinance the costs of all improvements must be monitored. The costs of any improvements in the past 12 months and the costs of any proposed improvements must be shown on the worksheet. The cost of improvements must include demolition, raw and finished materials (include those donated), labor (including volunteer and self - performed), construction supervision and management, and overhead and profit. A list of items the costs of which are to be included as well as those excluded is attached for your reference. (A Co of the Contract must be ttached) PROPERTY OWNER: 't' !-Li i • fY,Dfl PERMIT # ADDRESS: lLiao /ve 10,3 rd S. FOLIO NUMBER: %!. 3 29(-. G 3 i k bd 30 FLOOD ZONE: BASE FLOOD ELEVATION: FREEBOARD: EAST OF FL.CCCL: COST OF PAST IMPROVEMENTS (12 MONTHS): 4 COST OF PROPOSED IMPROVEMENTS: 22, (ATTACH COPY OF CONTRACT) TOTAL CUMULATIVE COST OF IMPROVEMENTS (past and proposed): VALUE OF PRINCIPAL STRUCTURE (at OWNERS SIGNATURE: PLANREVIEWER: PLAN REVIEWER SIGNATURE: Created on June 2009 ach ap rais ): DATE: //.10 DATE: Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE RE- QUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR -RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1.2.3.4.5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Notice of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component Notice of Acceptances 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Re- Roofing Only) 7. Any Required Roof TestinglCalculation Documentation 11 �Yo - - - - - .1dIng Code Edition 290 1_,. High Velocity Hurricane Zone Uniform Fermi �jal ' "n r� wI a H ALL FE�UEAJ Section A (General Inforin�l`C1b) 0 CCMPIJANCE hr HL_E AND RE0IL4Ti0H Master Permit No. Process Contractor's Name 0 Vt 00( Job Address 1 d ROOF CATEGORY Low Slope ❑ Mechanically Fastened Tile 412 Mortar /Adhesive Set Tile Asphaltic Shingles ❑ Metal Panel /Shingles ❑ Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof '�C e- Roofing ❑ Recovering ❑ Repair ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) ❑ Maintenance 169 41 Li 30V 1 ' j j j 1i / Section B (Roof Plan) +' Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow Jscu fliers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of-elevated pressure zones and location of parapets. ...4; �_� 1 ��n VR t 17� "*3 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High- Velocity Hurricane Zone Uniform Permit Application orm. Section C (Low SipaApplication' Fill in specific roof assembly components and Identify manufacturer (If a component Is not used, Identity as "NA ") System Manufacturer: Product Approval No.: 07 1?!' e Design Wind Pressures, Fromm RAS 128 or Calculations: Pmaxl: Pmax2: yb Pmay0 7 Max. Design Pressure, fromtttie sp8oific Product Approval system: Deck Type: �Hd u Oauge/Thic nags: 3/y % Slope: �° Anchor/Base Sheet & No. of Piy(s): t1'%/I t4 4� k Anchor/Base Sheet Faste r/Bo Ing Material: Insulation Base Layer: /549 e iid , r /' i 0 i base Insulation Size and Thickness: Lf P 7 a //y Base Inauop Fast �/ fJ Top Insulation Layer: Al Top Insulation Size and Thickness: Top Insulation Fastener ing Material: Base Sheet(s) & No. of Ply(s) Base She Fgst#ner/ ridi� Ma erial: Ply Sheet(s) & No. of PIy(e): Ply Sheet Fes ; ner /B Top Ply: Top Ply r r/B Ing IIlat FLORIDA BUILDING CODE — BUILDING 3` Surfacing: % Fastener Spacing for Anchor /Base Sheet Attachment: Field: " oc 0 Lap, # Rows 1 -ac Perimeter: 4- " oc c+ Lap, # Rows I 0 d " oc 7 Comer: 6 " oc 0 Lap, # Rows - @ �' " oc 4' Number of Fasteners P$r sulation Board: Field rrmeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit 0 4i5/`�2/P0 3;q 5/—,- ///- milt- 6v 77/r'l.4 FT. Parapet Height <4 r 41/1/0- Af i/ /Zs /gzte✓ 4 `oc .2414. 941 aru ee w Mean Roof Height 15.33 Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: 6�1,4CA ic1A! e Notice of Acceptance Number: ® 11 • D 1 Minimum Design Wind pressures, If Ap cabbllep(From RAS 12 Pmax1: UPI Pmax2: f PS �i Pmax3: or Iculations): Maximum Design Pressure (From the NOA Specific System): IP ii Method of Tile Attachment: 1 I\ U A 1&1( Roof Slope: :12 eck Type: Sloped System Description Lk) oc ype Underlayment: nsulation: Ridge Ventilation A I R Ai) A Fire Barrier: I /J JA Mean Roof Height: Fastener Type & Spacing: s 618 i. u/ dhesive Type: I 5e [ JJ ,i 4/1erce ype Cap Sheet: Pn t7 61,45i Tv ®�J oofing Covering: I Oh"( eF K,,$14 Type & Size Drip dge: I .24 se,. fie) di cot Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment -based tile systems, choose either Method 1 or 2. Compared the values for Mr with the values from M. If the M1 values are greater than or equal to the Mr values for each area of the roof, then the tile attachment method is acceptable. Method 1 ", oment -Based Tile Calculations er RAS 127" (PI:,: )(A, 6, X13 _ 1) - Mg: „�a = Mn ' al) - NOA M� '.t`. (P' x R l _ �: ) - Mg: ? =M i/ . ; NOA Mr 'Mar (PZ �� ` x /1 e '))1 _ ' �r : ' ) - Mg: 'r '� = M� NOA Mr 1[l ' Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below NOA Mr Mr Required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2 :12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 ; 28.2 30.0 *Must be used in conjunction with a list of moment -based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift -based tile systems use Method 3. Compared the values for F' with the values for Fe If the F' values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift -Based Tile Calculations Per RAS 127" (P1:_ xI: =_xw:= W:_xcos 8: =F NOA Fl _ _)- ,1: (P2:_ x I: = x w: = - W:_ x cos 8: = Fes: NOA F1 _ _ _) (P3:_ xI: W:_xcos 6: =F�• NOA F1 _= _xw:= _)- Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x NOA Restoring Moment due to Gravity Mp NOA Attachment Resistance M, NOA Required Moment Resistance M, Calculated Minimum Attachment Resistance F' NOA Required Uplift Resistance F, Calculated Average Tile Weight W NOA Tile Dimensions I = length w = width NOA All calculations must be submitted to the Building Official at the time of permit application. Owner's Notification Form 07 . SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractokto provide the owner with the required roofing permit, and to explain fo the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item ► been explained. I11. Aesthetics: workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zo e): e for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color dr architectural appearance, that are not part of a zoning code, should be addressed as p. of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be r ai ed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Buildin • Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring .e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or ould notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be v ew d from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of i ning this appearance. 171 5. Ponding water: The current roof system and/or deck of the building may not drain well and may c' use water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofi 1 system is removed. Ponding conditions should be corrected. MI16.Overflow scuppers .(wall outlets): It is required that rainwater flow off so that the roof is not o erloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow uppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with equirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. It 1 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the in erio' of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida - licensed engineer or registered architect to eliminate the attic venting, venting shall not be require Owner's /Agent's Signature: Contractor's Signature: Property Address: I Date: / Permit Number: r1 M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) MonierLifetile, LLC 200 Story Road Lake Wales, FL 33853 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the .expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 07- 0228.03 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Pagel of 7 • ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: Roofing Flat Profile Roofing Tiles Concrete SCOPE: This new NOA approves a system using MonierLifetile Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile, as manufactured MonierLifetile LLC and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. PRODUCT DESCRIPTION Manufactured by Applicant MonierLifetile LLC Saxony 900 Trim Pieces Dimensions 1 =17" w= 13" 1- 5/32" thick Slate 1- 9/32" thick Shake & Split Shake 1= varies w = varies varying thickness SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Test Specifications TAS 112 TAS 112 Test Identifier 7161 -03 Appendix III 94 -084 94-060A 25- 7183 -6 25- 7183 -5 Product Description Flat profile, interlocking, high- pressure extruded concrete roof tile equipped with two nail holes. For direct deck or battened nail -on, mortar set or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Oat Static Uplift Testing Dec. 1991 PA 102 & PA 102(A) Static Uplift Testing May 1994 PA 101 (Mortar Set) Static Uplift Testing March, 1994 PA 101 (Adhesive Set) Static Uplift Testing Feb. 1995 PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing Feb. 1995 PA 102 (2 Quik -Drive Screws, Battens) NOA No.: 07-0711.03 Expiration Date: 04 /26/12 Approval Date: 09 /07/07 Page 2 of 7 Test Agency, The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineers Test Identifier, 25- 7214 -1 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 P0402 Project No. 307025 Test #MDC -77 R1.894 R2.894 R3.894 520109 -1 520111 -4 520191 -1 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations Evaluation Calculations 130 Test Name/Report Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Static Uplift Testing PA 101 Static Uplift Testing PA 101 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moments Due to Gravity TAS 112 Date March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 March 1995 January 2007 April 1999 February 2007 January 2007 NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page 3 of 7 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3. Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 4. Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 5. 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 6. This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. INSTALLATION: 1. MonierLifetile Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofmg Application Standard RAS 118, RAS 119, and RAS 120. 2. Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) MonierLifetile Saxony 900 Slate, Shake & Split Shake 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - X ft3) Tile I (ft) ), (ft) Profile Batten Application Direct Deck Application MonierLifetile Saxony 900 0.289 0.313 Slate, Shake & Split Shake Battens Direct Deck Table 3: Restorin s Moments due to Gray - M ft-lb Tile Profile 2 ":12" 3 ":12" 4 ":12" 5 "•12" 6 ":12" 7 ":12" or greater Saxony 900 Slate, Shake & Split Shake Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.16 8.12 7.08 8.03 6.97 7.91 6.82 7.74 6.65 7.55 6.46 7.34 NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09/07/07 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-Ibt for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Saxony 900 Slate, Shake & Split Shake 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment M1(ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Adhesive 31.3` 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Polyfoam PotyProTM 118.9' Polyfoam PotyProTM 40.44 3 Large paddy placement of 45 grams of PolyProT". 4 Medium paddy placement of 24 grams of PolyProT"". Table 5B: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Mortar Set' 43.9° 5. Tile -Tite Roof Tile Mortar NOA No.: 07-0711.03 Expiration Date: 04/26/12 Approval Date: 09/07/07 Page 5 of 7 LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". MONIEIELIFETILE LLC, SAXONY 900 Tux (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING WATERLOCK MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL) NOA No.: 07- 0711.03 Expiration Date: 04/26/12 Approval Date: 09 /07/07 Page 6 of 7 PROFILE DRAWING MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SPLIT SHAKE MODEL) MONIERLIFETILE- SAXONY 900 CONCRETE ROOF TILE (SHAKE MODEL) END OF THIS ACCEPTANCE NOA No.: 07-0711.03 Expiration Date: 04/26!12 Approval Date: 09/07/07 Page 7 of 7 MIAMI COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA # 09- 0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub - Category: Underlayment Material: SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Facer of Membrane with surface printing) Manufacturing Location #1 & #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 MIAMI•DADE COUNTY APPROVED Dimensions Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 80 mils thick Roll: 32' 10" x 3'33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'3-3/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A fine granular /sand top surface self-adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non - wicking fabric surfaced, self-adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass -fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 2 of 8 PRODUCTS DESCRIPTION: Product Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 61' x 3'3-3/8" 60 mils thick MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. MIAMI•DADE COUNTY APPROVED Test Specification ASTM D 1970 Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P36900.09.11 PRIO1111 PUSA- 005 -02 -01 PUSA- 018 -02 -01 PUSA- 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Product Description A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane, specific for use as a high temperature underlayment. Designed as a metal roofing. Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 09/01/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 -1/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS IR Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. MIAM4DADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 0 0 0 N CD Roofing Tiles (6 Max Per Stack) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI.DADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "712" or greater. It is suggested that on pitch/slopes in excess of 6'/a "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofmg Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 8 of 8 MIAMIM COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 1 I 805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 ww w.m i n m idad eaov /buildinu/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AII160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigers. MIAMJ.DADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications TAS 101 Polypro® AH160 N/A Foampro® RTF1000 ProPack® 30 & 100 N/A N/A Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Pronerty Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs. /fit.3 18 PSI Parallel to rise 12 PS1 Perpendicular to rise 28 PS1 Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158 °F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MANMADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTME84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANI3I -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. _W 2 F MS MIAMI•DADE COU APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® A11160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, Hig i Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro 0 AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. FDAD - CO APPROVED NOA No.: 11- 0124.04 Expiration Date: 05 /10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nil through plaint; cement Undertspnani l:ave course only: Keep adagio approx. 4 In. upfomwaephotes Paddy 1Mrmathitk} 10 b. EsasCahuse Esascaurseonly: Keepedheeiwepprox 4h.up fromweephotes MIAMI•DADE COUNTY APPROVED Fascia EaveClosure Rave course on,y: Keep gametes approx. 4 In. up from wormholes 1) Piece mph adhesive to achieve 1710 23 Optimal k4etor square Inches hooted w0hthe pan Ole \ steep pitch applications 2j T1Place edl VI omoo eedgecco► erll. . Then install the t?e: Nag through pisstc oernent Re top peon of theeare course cover tile. Abut to second course of panties. Ensure cave end of paned Wier Wes me flush el save Ilne. Ewe done Weephote Fascia (mortar shown) NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04 /14/11 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement Undertayment Paddy (Beneath Tile) 7 fi. ,In. Eave Courae Fascia Weaphde Eava closure Drip edge Nail through plastle cement MIAMLDADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04 /14/11 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy (between tile) Paddy (under tile) 3 In x 3 In. Single paddy on under - layment Single paddy under tile Single paddy on top of file Eave course In. X7in. medium slue paddy save Fascia course only MIAMI ADE C APPROVED NTY Nall through plastic cement Nall through plastic cement Single paddy under tile Underlayment Single paddy between tile 21n. x 7 In. mum site paddy eave course only ! �' in.x3In. Single 41n. paddy on under - layment Single paddy on top of the Eave Course Fascia Weaplieie Eave closure Drip edge Single paddy between tile Single paddy on underlayment In.x31n. 4 In Single paddy on top of the Eave Course Eave Closure 2 In. x 7 In. medium alto paddy ears course only Fascia END OF THIS ACCEPTANCE NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7 BUILDING CODE COMPLIANCE OFFICE (BCCO) • PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI -DADS COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 GAF Material Corporation. 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as desdribed herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 throygh 19. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI.DADE C • UNTY APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 1 of 19 4 f ROOFING SYSTEM APPROVAL Category: Roofing Sub- Cateeorv: BUR Deck TvAe: Wood Maximum Desisn Pressure -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Leak BusterTM MatrixTM 307 Premium Asphalt Primer Test Dimensions Specification 3, 5, 55 gallons ASTM D 41 ASTM D 1863 ASTM 1227 GAF Mineral ShieldTM 60 & 1001b. bags Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM 322 Elastomeric Roof Coating LeakBusterTM MatrIxTM Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 204 Wet/Dry Roof Cement RUBEROID® Modified Bitumen Flashing Cement LeakBusterTM MatrixTM 201 Premium SBS Flashing Cement GAFGLAS® #75 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 5 gallons 5 gallons Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing.. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating. Elastomeric roof coating. Asphalt emulsion fbered. ASTM D -4586 Refined asphalt blended with a mineral . ASTM D -3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4586 Fiber reinforced, polymer modified Flashing cement ASTM D 4586 Asphalt flashing Cement 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 APPROVED ASSEMBLIES Deck Type 1I: Wood, Insulated • Deck Description: 19/32" or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. . Insulation Layer (Table 2) Insulation Fasteners Fastener • (When applicable: Steel plate only =S, plastic plate only (Table 3) Density /ft2 P). EnergyGuardTM, EnergyGuardTM Composite, EverGuard® ISO,'EnergyGuardTM RA, EnergyGuardTM RA Composite • Minimum 1 "thick N /A' N/A EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board, Wood Fiber, Minimum V2" thick EnergyGuardTM Perlite Minimum %" thick Fiberglas (Min. 15 /16" thick) N/A N/A N/A N/A N/A • N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20 -40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® STRATAVENT® EliminatorTM Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Anchor sheet: GAFGLAS® #80 ULT1MATM Base Sheet, STRATAVENT! EliminatoirM Nailable, RUBEROID Modified Base Sheet, RUBEROID 20, RUBEROID Heat - WeIdTM Smooth or RUBEROID® Heat - WeIdTM 25 base sheet mechanically fastened as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —4S psf, See General Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 8 of 19 Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) .GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a . fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved 11/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 pssf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill - TeeTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIIMATM Base'Sheet, GAFGLAS® STRATAVENT® EliminatorTM Perforated, RUBEROID® Modified Base Sheet, RUBEROID® Mop Smooth, RUBEROID® 20 RUBEROID® Heat- We1dTM Smooth or RUBEROID® Heat- WeldTM directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq; (see General Limitation #4). One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet, #80 Ultima, RUBEROID® Mop Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 Ibs./sq. Base Sheet: Ply Sheet: MIAM DADECOUNTY APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 9 of 19 Cap Sheet: Surfacing: (Optional) One ply of GAFGLAS'' Mineral Surfaced Cap Sheet or GAFGLAS ®EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 Ibs. /sq. respectively in a flood coat of approved asphalt at 60 Ibs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galisq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield`a SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal. /sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 10 of 19 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex PIyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" Dens DeckTM or ' / ?" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor /base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and /or flashing termination designs shall conform with Roofmg Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this . limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 19 of 19 e ? k 192 2007 ROOFING MATERIALS AND SYSTEMS UltitL I UHT ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued Base Coat "A-38 Series ", 0.75 gal /sq. Second Base Coat "A -38 Series ", 0.75 gal /sq. Wear Coat "A -38 Series °, 0.75 gal /sq plus walnut shells•at 0.75 lbs per sq. acing: A-38 Series ", 0.75 gal /sq plus walnut shells at 0.75 Ibs per 46 D k: NC Incline: 3/4 Foam: Spray application of 2 -in. thick "Polyfoam 273" (2.7 lb /ft.3 ) Surfacing: Spray application of 28 to 34 -mils "U -8730" (aluminum) 47 Deck: NC Incline: 1/2 Insulation: Spray application of 2 -in. thick " Polyfoam 273" (2.716/ft.3 Surfacing: Spray application of 28 to 34 -mils "U -8782" (ivory) GAF MA.I.EItIALS CORP R1306 1361 ALPS RD, WAYNE NJ 07470 "Ruberoid 20" or "Ruberoid Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and . overlayment board are offset•6 in. with the joints in the deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Also, multiple plies of "GAFGLAS Ply 4" or "Ply 6" may be adhered to GP Gypsum DensDeck® in hot asphalt. "EnergyGuard Ultra" is an acceptable alternate to " EnergyGuard" in any applicable Classification. GAF Stratavent Eliminator Venting Base Sheet (Nailable)" may be mechani- cally attached or hot mopped over noncombustible decks and as a recover over existing roof systems. GAFGLAS Perlite Insulation may be utilized as a cover board over "EVER - GUARD" insulation in any of the following systems. Unless otherwise adhered with hot mopping indicated, orurethane�insulation mechanically fastened, - rene reference in any of the following Classficatons include "ENERGuardyEPS Insulation ". References to glass fiber insulation include "EnergyGuard Fiberglass insu- lation". ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type_ G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet" or "OAFLAS #80 ULTIMA" ) is a suitable alternate for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS PIy 6" ) in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAF Stratavent Eliminator Venting Base Sheet (Perforated)" or "GAF Stratavent Eliminator Venting Base Sheet ( Nailable)" . Perforated to be mopped and nailable to be mechanically attached granule side down. As an option Type G2, asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet ", " GAFGLAS #80 ULTIMA" or "GAF Stratavent Eliminator Venting Base Sheet ("GAFGLAS Ply 4" may GAFGLLAS Ply 6" )1 as hie Inailed baserp y sheet following systems. 4" , Bottom ply or base sheet may be solid mopped, spot mopped or mechani- cally fastened. Unless otherwise indicated, all insulations may be hot mopped or mechani- cally fastened. "GAFGLAS Flashing" or "Ruberoid" may be used for Clashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE ®" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems lii;tgd. Structural ceineit fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use,of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin paper (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the following Class A, B or C systems. "BMCA EnerayG,uard RA ", "BMCA Tapered EnergyGuard RA" and "BMCA EnerryGuard A' may be substituted for any Atlas polyisocyanurate insula- tion m any of the following Classifications. Trumbull "Perna Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". GAPG1)AS'#80 Premiuin Base Sheet may be used in any of the following st ys ems. " GAFGLAS Fiex Ply 6" is a suitable alternate to " GAFGLAS Ply 6 ". LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued "GAFTEMP Permalite Recover Board" may be used in lieu of any per insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with 1 Roofing Asphalt" may be surfaced with "Fieshield MB" at 2.5 — 3.0 gal /s Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitun membranes. "Ruberoid Heat Weld" SBS roofing membrane may be used in lieu "Ruberoid Mop" SBS products in any applicable Classification. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, gl fiber, isocyanurate, urethane, perlite / isocyanurate composite, perli urethane composite, wood hoer / isocyanurate composite, phenolic, : thickness. Ply Sheet Three or more layers Type G1 "GAFGLAS Ply 4" " GAFGLAS Ply 6 ", hot mopped. Surfacing: Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): 'One or more layers perlite, wood fiber, gl fiber, isocyanurate, urethane, perlite / isocyanurate composite, perli urethane composite, wood fiber /isocyanurate composite, phenolic, thickness, PIy Sheet:* Three or more layers Type GI " GAFGLAS Ply 4" " GAFGLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced t Sheet" or "EnergyCap Mineral Surfaced Cap Sheet". 3. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, g fiber, isocyanurate, urethane, perlite / isocyanurate composite, pert: urethane composite, wood fiber /isocyanurate composite, phenolic, 2 Ply Sheet: Two or more layers,Type Gl " GAFGLAS Ply 4" or "G. GLAS Ply 6" Cap Sheet One layer Type G3 "GAFGLAS Mineral. Surfaced Sheet" or "EnergyCap Mineral Surfaced nCap Sheet". 4. Deck: NC Insulation: One or two layers "Isotherm R ", 4 in. max, hot moppe Ply Sheet Any UL Classified gravel surfaced C1acs A asphalt glass f mat system. Incline: 1 5. Deck: C -15/32 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet One layer Type G2 " GAFGLAS #75 Base Sheet" (ma) nailed). PIy Sheet: One or more layers Type GI " GAFGLAS Ply 4" or GAFGI Ply 6 ". Cap Sheet: One layer Type G3 " GAFGLAS Mineral Surfaced': Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". 6. Deck: NC Incline: 3 Base Sheet One layer Type G2 " GAFGLAS #75 Base Sheet ". Ply Sheet: One or more layers 'Type Gl " GAFGLAS Ply 4" or "G GLAS Ply 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfacer:VI Sheet" or " EnergyCap Mineral Surfaced Cap Sheet ". • 7. Deck: C -15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, thane, perlite / isocyanurate composite, perlite /urethane composite;) nolic, 1.0 in. min (offset from plywood joints 6 in.). Base Sheet One or more layers Type Gl, G2 or G3. � Membrane: One or more layers' Ruberoid Torch" (Smooth or Gra "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (Smooth or G' or "Ruberoid Mop Plus" (granule). Cap Sheet Type G3 "GAFGLAS Mineral Surfaced Cap S " EnergyCap Mineral Surfaced Cap Sheet ", hot mopped. 8. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber fiber, isocyanurate, urethane, perlite / isocyanurate composite, urethane composite, wood fiber / isocyanurate composite, pheno thickness. Base Sheet Two or more layers Type G2 or G3. . Ply Sheet (Optional): One or more layers Type Gl. Membrane: One or more layers "Ruberoid Torch" (mooch or G "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (Smooth or G or "Ruberoid Mop Plus" (granule). _LUU/ HUUrINU MIMI- CrIIML.J MI\Y J 1 J 1 cm.. vu Iw . ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)- Continued Cap Sheet Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ", hot mopped. 9. Deck: NC Incline: 2 Insulation (Optional): Perlite, glass fiber, polyisocyanurate, wood fiber, mechanically fastened, any thickness. Base Sheet: One or more layers Type G2, "GAFGLASS #75 Base Sheet ". Ply Sheet: One or more layers Type GI "GAFGLAS Ply 4" or " GAFGLAS Ply 6 ". Cap Sheet Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Surfacing: "Fireshield MB ", 25 - 3.0 gal. /sq. Class B 1. Deck: C -15/32 Incline: 3-1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Two or more layers Type G1 "GAFGLAS Ply 4" or "GAF - GLAS Ply 6" Cap Sheet: Type .G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ", hot mopped. 2. Deck: C -15/32 Incline: 3-1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood fiber / isocyanurate composite, phenolic, any thickness. Base Sheet: Two or more layers Type Gl, G2 or G3. Membrane One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (Smooth or Granule) or " Ruberoid Mop Plus" (granule). Cap Sheet: " GAFGLAS Mineral Surfaced Cap Sheet" or " EnergyCap Mineral Surfaced Cap Sheet ", hot mopped. Class C 1. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type Gl " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing "Special Roofing Bitumen" 20 lbs /sq. COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR Class A 1. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood fiber / isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type G1 " GAFGLAS PIy 4" or " GAFGLAS Ply 6 ", hot mopped with coal tar bitumen. Surfacing: Gravel. COMBINATION HOT AND COLD SYSTEMS Class A 1. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber or glass fiber, 2 in. max. Ply Sheet: Three or more layers Type GI "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: Grundy Industries "al MB Aluminum Roof Coating" at 1 -1/2 gal /sq. Incline: 1 2. Deck: NC Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber / isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing. "Weather Coat Emulsion" at 3 gal /sq. 3. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in., hot mopped. PJySheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. 4. Deck: NC Incline: 2 ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)- Continued Insulation (Optional): Isocyanurate, perlite, isocyanurate /comp wood fiber and glass fiber, any thickness, mechanically fastened. Base Sheet One ply Type Gl or G2, mechanically fastened o PIy Sheeet: One or more plies Type GI or G2, adhered with hot ro asphalt. Surfacing: "GAF Premium Fibered Aluminum Roof Coating ", ' gal /sq or "GAF Weather Coat Emulsion ", 3 gal /sq. 5. Deck: NC Incline( Insulation (Optional): Perlite, glass fiber, polyisocyanurate, wood mechanically fastened, any thickness. Base/Ply Sheet: One or more plies Type G1 or type G2, hot mopp place. Coating: "Fibered Aluminum Roof Coating ". 6. Deck: NC Incline:1 Insulation (Optional): Perlite, glass fiber, polyisocyanurate, wood mechanically fastened, any thickness. Base/Ply Sheet One or more plies Type GI or Type G2, fully ad with either " Ruberoid Modified Bitumen Adhesive" or "Ruberoid I feed Bitumen flashing Cement ". Coating: "Fibered Aluminum Roof Coating ", 1 -1/2 gal /sq. 7. Deck: C 15/32. Incline: 1 Base Sheet One or more plies Type G2, mechanically fastened. Pty Sheet: Three or more plies Type GI, hot mopped in place. Coatings: " Fibered Aluminum Roof Coating", 1-1/2 gal /sq. 8. Deck: NC Incline: 1 Base Sheet: Any UL Classified Type GI or Type G2 base mechanically fastened. Base Sheet plies, fully adhered UL with "Matrix Standard Cold Lap Adhesive 1 gal. /sq. Surfacing: "Matrix 322 White Elastomeric Roof Coating ", 2 gal. 9. Deck: NC Incline: 1/2 Insulation (Optional): Petlitg, glass fiber, polyisocyanurate, fiber, mechanically fastened, any thickness. Ply Sheet Three or more layers Type GI " GAFGLAS Ply 6 Surffacciing: " Fireshield MB ", 15 - 2.0 gal. /sq. Class B 1. Deleted Incline: 2. 2. Deck: C -15/32 Insulation (Optional): One or more layers perlite, wood fiber fiber, isocyanurate, urethane, perlite / isocyanurate composite, p urethane composite, wood fiber /isocyanurate.composite, phenol thickness. Ply Sheet Three or more layers Type G1 " GAFGLAS Ply "GAFGLAS Ply 6 ", hot mopped. Surfacing. Grundy Industries' "al MB Aluminum Roof Coating" gal/sq. Incline 2 3. Deck: NC Insulation (Optional): One or more layers perlite��ood fbe1 fiber, isocyanurate, . urethane, perlite/isocyanurate-composite, F. urethane composite, wood fiber / isocyanurate composite, phenol thickness. - Ply Sheet: Three or more layers Type GI " GAFGLAS Ply "GAFGLAS Ply 6" Surfacing: "Weather Coat Emulsion AF" at 1 -1/2 gal /sq. Class C I. Deck: C -15/32 Incline: Unlimited Insulation (Optional): One or more layers perlife, wood fiber c fiber, 2 in. max. Ply Sheet Three or more layers Type Gl " GAFGLAS Ply "GAFGLAS Ply 6 ": Surfacing: Grundy Industries "al MB Aluminum Roof Coati • 1 -1/2 gal /sq or "Weather Coat Emulsion" at 3 >.gal /sq. 2. Deck: C -15/32 Incline: 2. Insulation (Optional): One or more layers perlite, wood fibe fiber, isocyanurate, urethane, perlite / isocyanurate composite, } urethane composite, wood fiber / isocyanurate composite, pheno thickness. Ply Sheet Three or more layers Type G1 ."GAFGLAS Ply "GAFGLAS Ply 6 ". Surfacing. Grundy Industries "al MB Aluminum Roof Coat 1 -1/2 gal /sq. LOOK FOR THE UL MARK ON PRODUCT NOTICE OF COMMENCEMENT I IIIIII 11111 VIII VIII 11111 VIII 1111111111111 A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION p PERMIT No8t -2707 -� /3 TAX FOLIO NO. / —37. -O - 031 -Uo ;' STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information ' is provided in this Notice of Commencement. CFN 2i i12Ri 408.3652 OR Bk 27987 F's 3767; (1Ps) RECORDED 02/06 /2012 15:2:3 0 HARVEY RUVIH, CLERK OF COURT MIAMI-DADE COUNTY? FLORIDA LAST PAGE 1. Legal description of property and street/address: "fib PE /03 pn i d.yy J. 6h0 rat 3,) lg 2. Description of improvement: 3. Owner(s) name and address: C e Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: 5. Surety: (Payment bond required by owner from contractor, if any) OT , Name and address: Amount of bond $ 6. Lender's name and address: 1 ! !ERESY °C EFf F`t c rtinsi r "alt f;-,is tiv:... 3 cn HARV ' :E It. CI FBI£ u RaorR M ^ii ;iCl I G9an;r: amts may be served as 7. Persons within the state of Florida designated by Owner upofpiY provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 4 ) I 8. In addition to himself, Owners designates the folio in Section 713.13(1)(b), Florida Statutes. Name and address: ing person(s) to receive a copy of the Lienor's Notice as provided 1 9. Expiration date of this Notice of Commencement: the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner Print Owner's Name Sworn to and subscribed before me this / n Notary Public %.(/4I/Of Print Notary's Name My commission expires: 123.01 -52 PAGE 4 10/04 kohl day of 0---Q,n PiT,i�U^C-- S��'!ATE O I 4` c d D. wires: APR. 02, 2013 Prepared byc., 20 '' �, Address: Lke0gl /144:5t S f 1 t