Loading...
SGN-11-1446Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 167552 Permit Number: SGN -8 -11 -1446 Scheduled Inspection Date: February 01, 2012 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Miami Shores, FL 33138- Project: BARRY UNIVERSITY Contractor: TGSV ENTERPRISES INC Permit Type: Sign Inspection Type: Final Work Classification: New Phone Number Parcel Number 1121360010160 Phone: (305)323 -5755 Building Department Comments MONUMENT SIGN ON NE 2 AVE NORTH CORNER Passe Aa Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 167424. CREATED AS REINSPECTION FOR INSP- 163062. CANCELLED BY ANNIE Letter loose on wall. Provide attachment detail from designer showing method of attachment to resist the wind Toads form 146 mph winds. January 31, 2012 For Inspections please call: (305)762 -4949 Page 14 of 39 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 1 Permit No.9 l F (4-4( Master Permit No. BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING ROOFING Owner's Name (Fee Simple Titleholder) Barry University Owner's Address City Miami Shores Tenant/Lessee Name Email 11300 NE 2nd Ave )41 -j, BY: Phone # State FL Zip 33138 Phone # Job Address (where the work is being done) City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # 11- 2136 -000 -0050 Is Building Historically Designated YES NO Flood ZonoCcabLiPL Contractor's Company Name TGSV Enterprises, Inc. Phone # 305 - 823 -5755 vC.7S•noa Contractor's Address 1301 West 68th Street City Hialeah State Florida Zip 33014 Qualifier Name Rny Rniri viP7. Phone # 305 -823 -5755 State Certificate or Registration No. Certificate of Competency No. Contact Phone 305 -970 -6279 E -mail roy@tgsv.com Architect/Engineer's Name (if applicable) Manuel Synalovski Phone # 954 - 961 -6806 Value of Work For this Permit $ 14 C)_ _ Square / Linear Footage Of Work: N/A Type of Work: X Addition ['Alteration ENew El Repair/Replace ['Demolition Describe Work: Signage structures CO Alj,ipU,thEl J S((*J ******** * * * * * * * * * * * * * * * * * ** * * * *xxxxx * ** Fees*********** x******* Ar*$ rdrsr xer9e4e4r9e4e******* *dre6*** Submittal Fee $ Permit Fee $ (00 CCF $ CO /CC $ Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Bond $ Double Fee $ Violation date: Structural Review. $ Total Fee Now Due $ bil5 See Reverse side -+ 4Bondmg Company's Name (if applicable) Bonding Company's Address City N/A State N/A Zip N/A N/A N/A Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City N/A N/A State N/A Zip N/A Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approves and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of altstAg , 20 I , by r3Qkc cD1v14( who is personally known to me or who has produced l S� As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: t Signature °:.'"_.__...- Roy Rodriguez Contractor The foregoing instrument was acknowledged before me this 29th day of July , 201L, by Roy Rodriguez who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: sabel Camejo —St' t My Commission Ex * * * * *** * * * * * ** * *** * * * * * * * * * * * *** tea ** * * * * * * * * * * * * *x* * * * * * ** ** * * * ** *xxxxxxx * * ** APPROVED BY 53:—PrirPlans Examiner Engineer (Revised 07 /10 /07)(Revised 06/10/2009) r • Nb ISABEL CAMEJO SMITH MY COMMISSION # DD982630 %an, EXPIRES: June 14, 2014 1.90031t6'[ARY FL Notary Discount ASSOC. Co. ** *xxxxxxx * * * * * * * * * * * * * * * * * *** Zoning Zoning Clerk checked ZnCI frent,uz _ akibk Permit No: 11 -1446 Job Name: August 11, 2011 Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Building Critique Sheet 1) Provide an electrical permit. 2) Provide wind load design criteria. 3) Top of foundation must be a minimum of 16' below finished grade. Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 IVliami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT PERMIT #: ` 4 yc DATE: ( ( I, AA ` Contractor o Owner ❑ Architect Picked up 2 sets of plans and (other) Address: From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: Ye).- C( PERMIT CLERK INITIAL: Permit No: 11 -1446 Job Name: August 11, 2011 Miami Shores Village Building Department Building Critique Sheet 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 1) Provide an electrical permit. 2) Provide wind load design criteria. 3) Top of foundation must be a minimum of 16' below finished grade. Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 • C Mil NW 11. Ave*. 1MS1. Feet Lasthert Ides It WS doi No: SI 1-- Date • laslossr 5$ := /44 Pre, ''..2"--=/./C CA isJ 0460 C'40 " 47.34 r*F ref 2 , / P‘ tope- C likr 45'4,41 6s,'_ VW •gsx �.s''a = C°• 4/ C wk's `� _ •�� 3 °+ �` qo. t S gr mss• 3Q tur X • ti x ri Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 pcf := lbf ft psf := lbf — f kip := 1000•Ibf plf := — lbf Job Title:BARRY MON. SIGN Project Number. 511-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Wind Design of Cantilever CMU Walls Effective Width of wall Resisting Load Per American Society of Civil Engineers, ASCE 7-05 "Minimum Design Loads for Buildings and Other Structures" Wind Velocity: V := 146 mph Building Category: II Importance Factor I := 1.15 Height of wall H := 633-ft Trib. Width b := 16in := 16-in Wind directionality factor. Kd := 0.85 (definedinsection6.5.4.4) pg. 80 Exposure "C" Velocity pressure exposure coefficient: KZ := 0.85 (definedintable6 – 3) pg. 79 Topographic factor. KA 1 (definedinsection6.5.7.2) "No change in topography, therefore not included" Velocity Pressure: qz := 0.00256•K0K .Kd•V2•I•psf pg. 27 qz = 45.34 psf Wind Pressure Gust Effect Factor. G 0.85 (definedinsection6.5.8.1) Using Force Coefficient Cf := 1.53 (definedinfigure6 — 20) p := gz•G•Cf Acting Wind Load p = 58.965 psf Total Load ww := p•b Ww = 78.61 ft Acting Moments M = - •(ww•H2) M = 15751bf•ft Material Properties fm := 1500-psi Em 900- (fm) (As Specified in Section1.8.2.2.1 of the ACI 530 Latest Edition) fs := 24000-psi Es := 29-106-psi Distance to Reinforcement Provided Area of Steel K .– n As Using bt For Initial Guess Value of yy := 1•in Distance to Neutral Axis y := root yy- (0.5)•yy + K•d yy yy +K d := 3.82-in As := 1•.31•in K = 0.416 in Es n := — Em n = 21.481 1#5 bar 16" O.C. Transform Moment of Inertia Compression Section Modulus Tension Section Modulus 3 Ix = bt3 + n•As•(d — y)2 Acting Stress Compression fc := M fc = 496 psi Sxc Tension fs := n--- M fs = 18266 psi Sxt y = 1.407 in Ix = 53.629 in Sxc = 38.107 in Sxt = 22.228 i 33 Allowable Stress < Fc := (..fm) Fc = 500psi Therefore OK < Fs := fs Fs = 24000 psi Therefore OK 8N,I% Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 psf := lbf pcf := lb — ft 3 Job Title:The BARR MON SIGN Project Number. S11-60 Sheet No. Date: 08/20/11 Calculated by S.E.H Footing Design for Cantilever CMU Walls 8" CMU Wall Weight W := 63-psf All. Soil Pressure qs := 2500-psf Moment capacity of the Floor Slab Conc. slab Comp. strength Slab Sect. Mod. AIIow. Conc. tension Allow. Slab Moment Acting Wall Moment Footing Overturning Moment Mo := M— Mn Density of concrete Density of Soil Slab thickness t2 S 6 Ft := 5• Pepsi Mn := Ft•S•b Assuming Footing Width bf = 3.0.ft Weight of Footing Weight of Wall Weight of Soil Total Weight Resisting Moments Factor of Safety Soil Pressure Load Eccentricity e = A?o Wt Allowable Soil Pressure for Wind Load Combinations Max Soil Press. Pc := 3000-psi S =Oin yc 145 }pcf ys := 11QTcf t := 04411 Ft = 274 psi Mn = Olbf•ft M = 1575.11bf•ft Mo = 15751bf•ft Assumed Ftg Depth Wf := D•b•bf•7c We := H -bt• W Ws := br7s.b•(1.33•ft) Wt := Wf +We +Ws Mr := 2•(wrbf) Mr FS : =M0 D 't= 1.041 Wf = 5801bf We = 5321bf Ws = 5851bf Wt = 16971bf Mr = 25451bf•ft FS = 1.616 e= 0.928ft bf = 0.5ft 6 x := 3•(0.5•bf— e) x = 1.72ft qs := 1.25•gs qs' = 3125psf > 1.5 OK < e ® Triangular Soil Pressure 2• Wt qa — x•b ,Required: qa = 1484psf Q"x 12" footing < qs OK Saad Elia El -Rage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771-8149 Factorized Moment psf := lbf ft Mu = Mr (1.4) For. d := D — 3.5- in d = 8.5 in fc' := 3000-psi :_ 2- (.594 -fc') F := bf -d2 Ku := Mu Ku = 2.4 kip (4)-fc') — 4(0 -fc')2 — 4•(.594- fc')-Ku Area of Steel Required Temperature Steel Required Use Cont x3'0 "x ft-ft Job Title:BARRY MON SIGN Project Number. S11 -60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Mu = 3.564 kip- ft fy := 60000-psi := .9 w= 6.1112x10 3 p := fY p = 0.00031 As := p•(18•in)•d AS = 0.047 in Astemp :_ .0018•b0D Astemp = 0.78 in `-0" Footing Reinf. WI 4 #5 Cont. Bott & #5 t 21' 0„C. Trans. Bo Deflection Check for Cantilever CMU Walls H = 6.33 ft Max Deflection @ Free End 8 = 0.38in 8 .— Ww H4 8•Em•lx H 180 = 0.42 in Therefore OK Requiredr8 "CMU Wall w! a #5( 16" O.C. for a G'-4" Cantilever CMU Wall is OK Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 pcf := lbf ft psf := lbf — ft kip := 1000• lbf plf := lft Job Title:BARRY MON SIGN Project Number. 511-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Wind Design of Cantilever CMU Wall Pilasters Height of Pilaster H := 8.83-ft Trib. Width b := 32in Effective Width of wall bt :— 32 in Resisting Load Per American Society of Civil Engineers, ASCE 7 -05 "Minimum Design Loads for Buildings and Other Structures" Wind Velocity: V := 146 mph Building Category: II Importance Factor I := 1.15 Wind directionality factor. Kd := 0.85 (definedinsection6.5.4.4) pg. 80 Exposure "C" Velocity pressure exposure coefficient: Kz := 0.85 (definedintable6 — 3) pg. 79 Topographic factor KA = 1 (definedinsection6.5.7.2) "No change in topography, therefore not included" Velocity Pressure: gz = 0.00256•Kz•KzrKd•V2•I•psf pg. 27 qz = 45.34psf Wind Pressure Gust Effect Factor. G := 0.85 (defined insection6.5.8.1) Using Force Coefficient Cf := 2.34(definedinfigure6 — 20) p = gz•G-Cf Actinq Wind Load p = 90.181 psf Total Load Ww := p•b Ww = 240.5f Acting Moments M := -12-(Ww-H2) M = 93751bf•ft Material Properties fm := 1500-psi Em := 900•(fm) (As Specified in Section1.8.2.2.1 of the ACI 530 Latest Edition) fs := 24000•psi Es := 29.106 -psi Distance to Reinforcement Provided Area of Steel n•A K :— s bt Using For Initial Guess Value of Distance to Neutral Axis Transform Moment of Inertia Compression Section Modulus Tension Section Modulus Compression Tension fc M Sxc fs : n•M Sxt y := root yy =_ 32" X 32" Pilaster d := 22 K = 0.416 in 1•in yy— (0.5)•yy +K•dl yy y = 4.426in yy +K Es n := — Em n = 21.481 One #5 rebar @ EA comer 3 Ix = bt3 +n•As•(d —y)2 Ix Sxc := — y Ix sxt :_ ( d- y) Acting Stress fc = 60 psi fs = 6842 psi IX= 8326 x 103 in Sxe = 1.881 x 103 in3 Sxt = 353.196 in3 Allowable Stress < Fc := C1 •fm I Fc = 500psi 3 < Fs := fs Therefore OK Fs = 24000psi Therefore OK Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 psf := — lbf ft pcf := —lbf ft Job Title:BARRY MON SIGN Project Number. S11-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Footing Design for Cantilever CMU Pilaster 8" CMU Wall Weight W := 75-psf Density of concrete ye := 145 -pcf All. Soil Pressure qs := 2500 -psf Moment capacity of the Floor Slab Conc. slab Comp. strength Slab Sect. Mod. Allow. Conc. tension Allow. Slab Moment Acting Wall Moment Footing Overturning Moment Mo := M — Mn S t2 := — 6 Density of Soil Slab thickness is 3000 -psi, S =Oin Ft := 5• fc-psi Ft = 274psi Mn := Ft•S•b Mn = Olbf•ft M = 9375.11 lbf•ft Mo = 93751bf•ft ys := 110'kpcf' t :_ �•in. Assuming Footing Width bf := 4.66741 Assumed Ftg Depth D := 133 -ft Weight of Footing Weight of Wall Weight of Soil Total Weight Resisting Moments Factor of Safety Soil Pressure Load Eccentricity e := MO Wt Allowable Soil Pressure for Wind Load Combinations Max Soil Press. Wf D•bf2•Yc We := H•bt•w Ws := bf-ys.b•(1.33•ft) Wt := Wf + We + Ws Mr := 2•(Wt.bf) FS := 6?r Mo Wf = 42001bf We = 17661bf Ws = 18211bf Wt = 77871bf Mr = 18171 ft• lbf FS = 1.938 > 1.5 OK e = 1.204ft bf = 0.778ft < e ® Triangular Soil Pressure 6 x := 3•(0.5•bf — e) x = 3.39ft := 1.25-cis 2-Wt qa — x•b gs' Required: 4'-8' qs' = 3125 psf qa = 1723psf < qs' OK 16" Footing Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 Factorized Moment psf := lbf ft 2 Mu := Mr•(1.4) For. d := D — 3.5. in d = 12.46 in fc' := 3000. psi :_ 24.59+fc') F bf•d2 Ku := Mu Ku = 5.1 kip (4 .fc') - J(4•0 2 - 4•(.59•4•fc')•Ku Area of Steel Required ft•ft w = 0.0131 Job Title:BARRY MON SIGN Project Number. S11-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Mu = 25.44 kip- ft fy := 60000-psi 4) := .9 fc' P w • fy As := p.(bf).d As = 0.457 in Temperature Steel Required AsCp :_ .0018•bf•D Asap = 1.61 in2 p = 0.00066 Use 4'48" x 4'43" x1•4" Footing Reinf. Wt 4 #5 EA. Wav Butt.' Deflection Check for Cantilever CMU Walls H = 8.83 ft Max Deflection @ Free End 5 = 0.03 in S Ww. H4 :— 8•Em 1x = 0.59 in Therefore OK 180 32" X 32" CMU Pilaster wt a # 5 tee' EA. Corner. is OK