Loading...
SGN-11-1444Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 167550 Permit Number: SGN -8 -11 -1444 Scheduled Inspection Date: February 01, 2012 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Miami Shores, FL 33138- Project: BARRY UNIVERSITY Contractor: TGSV ENTERPRISES INC Permit Type: Sign Inspection Type: Final Work Classification: New Phone Number Parcel Number 1121360010160 Phone: (305)323 -5755 Building Department Comments MONUMENT SIGN ON N MIAMI AV CORNER AND 115TH ST Passed Q/z,9 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 167427. CREATED AS REINSPECTION FOR INSP- 163060. CANCELLED BY ANNIE Letter loose on wall. Provide attachment detail from designer showing method of attachment to resist the wind loads form 146 mph winds. January 31, 2012 For Inspections please call: (305)762 -4949 Page 12 of 39 AA gird, II -4,06, BUILDING PERMIT APPLICATION FBC 20 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: BUILDING ROOFING Permit No. AUG IcrOMIVIED 0 9 20,1 1 BY: ... HL14c Master Permit No. Owner's Name (Fee Simple Titleholder) _Barry University Phone # Owner's Address 11300 NE 2nd Ave City Miami Shores State FL Zip 33138 Tenant/Lessee Name Phone # Email Job Address (where the work is being done) City Miami Shores Village FOLIO / PARCEL # 11- 2136 -000 -0050 County Miami -Dade Zip Is Building Historically Designated YES NO Flood Zone Contractor's Company Name TGSV Enterprises, Inc. Phone # 305 -823 -5755 Contractor's Address 1301 West 68th Street City Hialeah State Florida Zip 33014 Qualifier Name Rny Rndri gIipz Phone # 305 -823 -5755 State Certificate or Registration No. Certificate of Competency No. Contact Phone 305 -970 -6279 E -mail roy@tgsv.com Architect/Engineer's Name (if applicable) Manuel Synalovski Phone # 954- 961 -6806 Value of Work For this Permit $ L Of 000 _ Square / Linear Footage Of Work: N/A Type of Work: X Addition ['Alteration ❑New ❑ Repair/Replace ❑ Demolition Describe Work: Signage structures C b MONU1 r it c 1) ********* * *** * * ** * * ** ******* * * * * * * * * * ** Fees* ****** * **** ** * * * **** * * *** * * * ** * ** ** * * ** ** Submittal Fee $ Permit Fee $ ?O6 eg1 CCF $ CO /CC $ Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Bond $ Double Fee $ Violation date: �� _ ^ '� Structural Review. $ Total Fee Now Due $ `/i'�-6 See Reverse side - ®Blind ng 2ompany's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FJFCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AP'1'Il)AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved # a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this r day of IV S� , 20 I I , by �G6 LT J ba who is personally known to me or who has produced Signature__. Contractor The fore s g instrument was acknowledged before me this day of �.. , 201L, by �t� Cl'Ca2/QJ , 0 who is r ,1 onal ' known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Exp APPROVED BY 4,tS Plans Examiner Engineer (Revised 07 /10 /07)(Revised 06/10/2009) Sign: Print: • Ts My Commission Exp I'll : EL CAMEJO -SMITH MY COMMISSION # DD982630 °6 EXPIRES: June 14, 2014 '� Fi. Noaty Dimwit Assoc. Co. i.eoo.�xornaY ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Zoning Clerk checked PERMIT #: 1/1—. ) 11 Li Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT DATE: , i S ( 2_. I H I, /414 01)ei e ■Contractor ❑ wner ❑ Architect Picked up 2 sets of plans and (other) 4 Address: t3'� From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: CLERK INITIAL: /G //4 Permit No: 11 -1444 Job Name: August 11, 2011 Miami Shores Vivage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Building Critique Sheet 1) Provide an electrical permit. 2) Provide wind Toad design criteria. 3) Top of foundation must be a minimum of 16' below finished grade. Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 N. i i :Pmenta, ati- Permit No: 11 -1444 Job Name: August 11, 2011 Miami Shores Vuiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Building Critique Sheet 1) Provide an electrical permit. 2) Provide wind Toad design criteria. 3) Top of foundation must be a minimum of 16' below finished grade. Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 • SOU NW 06 Avee iMOi Pert Lauderdale, 11%. r-- / +4 tote, (-tri • .i C/ ,*s 0460 0040 fcrt-- Proiests Y % Jo No: / i 0 Dew : use:' i440 // r /"0."° -, 4.- 0 I° • sr gi 7, . stj cilser f s� 0 4I c A 2.GX•1 �— C� �c 141c 1.8)•.-“-) 4*.r csir . k. 44.p.Or- *s ° 3a •s Saad Elia El -Rage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 pcf := lbf — ft psf := lbf — ft kip := 1000• lbf pi 1 ft Job Title:BARRY MON. SIGN Project Number. S11 -60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Wind Design of Cantilever CMU Walls Effective Width of wall Resisting Load Per American Society of Civil Engineers, ASCE 7-05 "Minimum Design Loads for Buildings and Other Structures" Wind Velocity: V := 146 mph Building Category: II Importance Factor I := 1.15 Wind directionality factor. Kd := 0.85 (definedinsection6.5.4.4) pg. 80 Exposure "C" Velocity pressure exposure coefficient: K := 0.85 (definedintable6 - 3) pg. 79 Topographic factor. Kzt := 1 (definedinsection6.5.7.2) "No change in topography, therefore not included" Velocity Pressure: qZ := 0.00256•KZ KzrKd•V2•I•psf pg. 27 qZ = 4534psf Wind Pressure Gust Effect Factor. G := 0.85 (definedinsection6.5.8.1) Using Force Coefficient Cf := 1.53 (definedinfigure6 — 20) p ' gZ G Cf Acting Wind Load p = 58.965psf Total Load Ww := p•b Ww = 78.613 Acting Moments M :_ .(Ww•H2) M = 15751bf -ft Material Properties fm := 1500•psi Em := 900•(fm) (As Specified in Section1.8.2.2.1 of the ACI 530 Latest Edition) Height of wall H := 633-ft Trib. Width b := 16in —16•in fs := 24000•psi Es := 29- 106 -psi Distance to Reinforcement Provided Area of Steel n•As K .— d := 3.82•in As := 1.31•1n Using K = 0.416 in For Initial Guess Value of yy := 1 in [(0.5)-y yy + K•d 1 y := root yy yy + K J ,yy Distance to Neutral Axis Transform Moment of Inertia Compression Section Modulus Tension Section Modulus Compression fc := M Sx€ Tension fs := n- Sxt bt 3 Ix := bt3 + n•As•(d - y)2 Ix Sx,: =- y Sxt .— Ix (d— y) Acting Stress fc = 496 psi fs = 18266 psi Es n : — Em n = 21.481 1#5 bar @16 "O.C. y = 1.407 in Ix = 53.629in4 Sx, = 38.107in3 Sxt = 22.228 in3 Allowable Stress < Fc := (.fm) Fc = 500psi 3 < Fs := fs Fs = 24000 psi Therefore OK Therefore OK ■1, Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 psf := lb2 ft pcf := Ib3 — ft Job Title:The BARR MON SIGN Project Number. S11-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Footing Design for Cantilever CMU Walls 8" CMU Wall Weight W := 63-psf All. Soil Pressure qs := 2500-psf Moment capacity of the Floor Slab Conc. slab Comp. strength Slab Sect. Mod. Allow. Conc. tension Allow. Slab Moment Acting Wall Moment Footing Overturning Moment Mo := M – Mn Density of concrete Density of Soil Slab thickness fc := 3000-psi 2 S =t S =0in2 6 Ft := 5• fc-psi Ft = 274psi Mn := Ft -S•b Mn = Olbf -ft M = 1575.11bf•ft Mo = 15751bf•ft Assuming Footing Width bf := 3.0-ft Weight of Footing Weight of Wall Weight of Soil Total Weight Resisting Moments Factor of Safety Soil Pressure Load Eccentricity e := MO wt Allowable Soil Pressure for Wind Load Combinations Max Soil Press. yc := 145ipcf Ys: 110Jpcf t: 0-in Assumed Ftg Depth D := 1.041 Wf := D- b•bf-yc We := H•bt•W Ws := bf'ys.b.(1.334) Wt := Wf + We + Ws Mr := 2 •(wt•bf) FSMr : Mo e = 0.928 ft x := 3•(0.5 -bf — e) qs, := 1.25•gs 2-Wt ga — x•b Wf = 5801bf We = 5321bf Ws = 5851bf Wt = 16971bf M, = 25451bf•ft FS =1.616 >1.50K = 0.5 ft 6 < e ® Triangular Soil Pressure x = 1.72ft qs, = 3125 psf q$ = 1484psf < qs' OK Required: 3'- 0 "x 12" Footing Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 Factorized Moment psf := —lbf ft Mu := Mr (1.4) For. d := D — 3.5.in d = 8.5 in fc' := 3000.psi F := bf•d2 Ku := Fu Ku = 2.4 kip (4 -fc) 40402 — 4•(.59•0c') -Ku 2.(.59.4).0 Area of Steel Required Temperature Steel Required ft. ft Job Title:BARRY MON SIGN Project Number. S11-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Mu = 3.564kip•ft fy := 60000•psi .9 w= 6.1112x10 3 p =w•- p = 0.00031 As := p•(18•in) -d A3 = 0.047in2 Astemp := .0018 -bf•D Ast,p = 0.78in2 Use Cont. x 3'-0" x 1' -0" Footing Reinf. Who 115 Cont Bott. f #5 0112" O.C. Trans. ,Batt Deflection Check for Cantilever CMU Walls H = 6.33 ft Max Deflection @ Free End 8 = 0.38 in Ww•H4 8•Em Ix H = 0.42 in Therefore OK 180 Required: 8" CMU Wall w/ a # 5 @'lf" Q.C. for a 6'-4" Cantilever CMU Wall is OK Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 pcf := lbf ft psf = —lbf ft kip := 1000•lbf plf := lbf Job Title:BARRY MON SIGN Project Number S11-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Wind Design of Cantilever CMU Wall Pilasters Height of Pilaster H := 8.83•ft Trib. Width b := 32in Effective Width of wall =_32 in Resisting Load Per American Society of Civil Engineers, ASCE 7-05 "Minimum Design Loads for Buildings and Other Structures" Wind Velocity: V := 146 mph Building Category: lI Importance Factor I := 1.15 Wind directionality factor Kd := 0.85 (definedinsection6.5.4.4) pg. 80 Exposure "C" Velocity pressure exposure coefficient IC := 0.85 (definedintable6 - 3) pg. 79 Topographic factor. KAt := 1 (definedinsection6.5.7.2) "No change in topography, therefore not included" Velocity Pressure: yZ := 0.00256•KZ•K2 •Kd•V2•I•psf pg. 27 q2 = 45.34psf Wind Pressure Gust Effect Factor. G := 0.85 (definedinsection6.5.8.1) Using Force Coefficient Cf := 2.34(definedinfigure6 — 20) p := o .G•Cf Acting Wind Load p = 90.181 psf Total Load Ww := p•b Ww = 240.5 lft M := .•(ww•H2) Acting Moments M = 93751bf -ft Material Properties fm := 1500-psi Em := 900•(fm) (As Specified in Section1.8.2.2.1 of the ACI 530 Latest Edition) fs = 24000-psi Es := 29-10 6 -psi 32" X 32" Pilaster Distance to Reinforcement d = 28.0•in Es n : — Provided Area of Steel 2 Em nAs As: =2.31 -in Using K ' bt K = 0.416 in n = 21.481 One #5 rebar @ EA comer For Initial Guess Value of yy = 1 in Distance to Neutral Axis y roo yy - (0.5 + K K d , yy Transform Moment of Inertia Compression Section Modulus Tension Section Modulus Compression fc := S Tension fs := n• M Sxt 3 Ix := bt y + n•As•(d — y)2 3 Sxc .— Ix y Ix Sxt :_ (d — y) Acting Stress y = 4.426 in Ix = 8.326 x 103 in Sx, = 1.881 x 103 in3 Sxt = 353.196 in3 Allowable Stress fc = 60psi < Fc := C' •fm I Fc = 500 psi Therefore OK 3 fs = 6842 psi < Fs := fs Fs = 24000 psi Therefore OK Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771-8149 psf := lbf pcf = lb — ft Job Title:BARRY MON SIGN Project Number. 811-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Footing Design for Cantilever CMU Pilaster 8" CMU Wall Weight W := 75-psf Density of concrete yc := 145•pcf All. Soil Pressure qs = 2500•psf Density of Soil Moment capacity of the Floor Slab Conc. slab Comp. strength Slab Sect. Mod. Allow. Conc. tension Allow. Slab Moment Mn := Ft•S•b Acting Wall Moment Footing Overturning Moment Ms := M — Mn S t2 := — 6 Ft = 5• fc•psi Slab thickness fc':= 3000•psil S =0in2 Ft = 274 psi Mn = Olbf•ft M = 9375.111bf•ft Mo = 93751bf•ft Ys : = 110 t := Q.in Assuming Footing Width bf := 4.667.ft Assumed Ftg Depth Weight of Footing Wf := D•bf2•yc Weight of Wall We := H•bt•W Weight of Soil Ws := brys b•(1.33•ft) Total Weight Wt = Wf + We + Ws Mr := 2•(Wt.bf) Mr Factor of Safety FS Mo Soil Pressure Resisting Moments Load Eccentricity e := W t Allowable Soil Pressure for Wind Load Combinations Max Soil Press. e = 1.204ft x := 3•(0.5•bf — e) x = 3.39ft qs� := 1.25.% = 3125 psf 2•Wt D := 1.33•ft Wf = 42001bf We = 17661bf Ws = 18211bf Wt = 77871bf p Mr = 18171 ft• lbf FS = 1.938 bf = 0.778 ft 6 > 1.5 OK f < e ® Triangular Soil Pressure x•b q$ = 1723 psf Required: 4'-8 "x 1'6" Foaiana < qs OK Saad Elia El -Hage Consulting Engineers 5601 N.W. 9th Av.Suite 401 Ft. Lauderdale, FL 33309 (954) 771 -8149 Factorized Moment w 24.59+fc') psf := —lbf ft Mu:= Mr(1.4) For. d := D — 3.5-in d = 12.46in fc' := 3000-psi F = bf•d2 Ku := Mu F (4)-fc) — 44•02 —44.59-0-0-Ku Area of Steel Required Ku = 5.1 kip ft-ft w = 0.0131 Job Title:BARRY MON SIGN Project Number. S11-60 Sheet No. Date: 08/20/11 Calculated by: S.E.H Mu = 25.44kip•ft fy := 60000-psi := .9 p := w p = 0.00066 As := p•(bf)•d As = 0.457in2 Temperature Steel Required Astemp := .0018•bf•D i1S Asten,p = 1.61 in2 Footing Reid, YV /'4 5' !. W v o Deflection Check for Cantilever CMU Walls H = 8.83 ft Max Deflection @ Free End 8 = 0.03 in S .— Ww H4 8—Em—lx = 0.59 in Therefore OK 180 Pilaster wl. a # .5 .(