Loading...
WS-10-2144Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)7564972 Inspection Number: INSP- 153942 Permit Number: WS -12 -10 -2144 Scheduled Inspection Date: November 14, 2011 Inspector: Bruhn, Norman Owner: HUTCHINSON, MARK Job Address: 1041 NE 96 Street Miami Shores, FL Project: <NONE> Contractor: RC CONSTRUCTION & INVEST, INC Permit Type: Windows /Shutters Inspection Type: Final Work Classification: Window /Door Replacement Phone Number Parcel Number 1132060143720 Phone: 305/975 -4156 Building Department Comments REPLACE EXISTING WINDOWS (10) AND DOORS (3) WITH IMPACT RESISTANT GLASS Passed M"4' Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments e*c November 10, 2011 For Inspections please call: (305)762 -4949 Page 5 of 34 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 RECEIVED ac' a 201 BY: Permit No. 6,0 S I 0 -- 4-1647L Master Permit No. Permit Type: PLUMBING OWNER: Name (Fee Simple Titleholder): TIM 4,k /11 L .L CL) Phone#: 941/' 4(/1(7". 9 70 Address: /0 W 963.S 74 --- City: /27/ /1-hi St/ 0/1.-L State: /1— .0 Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: / C 41 A/ z._-= eyt,..(-6z . , 2 2.- I' City: Miami Shores County: Miami Dade Zip: 3 / g Folio/Parcel#: / ( 2i) 6,:'0 / ‘74 7 Z. 0 Is the Building Historically Designated: Yes NO e..--- Flood Zone: CONTRACTOR: Company Name: Re c iO4icPhone#: 3 0-1) 7 7 4-- l71/ Address: / 2 7 CO S Lt: 4C sf- City: /I ( /)-in State: 7 Qualifier Name: /.??, C-4 re_clo iz 42,(c_44 Phone#: B 0 4---),13 7 4"--11-/ %.r4 State Certification or Registration #: e & ( 0 (f--- 2--t? Certificate of Competency #: Contact Phone#: 2 067 - 3 q9 3 Cr Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ f, C C C C Square/Linear Footage of Work: 46,4-4 Type of Work: °Address °Alteration ONew DRepair/Replace Description of Work: e4,41/-K- °Demolition Submittal Fee $ Permit Fee $ 250 CCF $ ' CO/CC $ Scanning Fee $ 3 .6) Radon Fee $ DBPR $ Bond $ Notary $ 5 Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 2-- ?, . L Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOII.RRS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AltIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occ rs eve (7) days after the building permit is issued. In the absence of such posted notice, the inspection will no be apI row •' a d a i ein pec '• - ' i .e charged. og Signature � LJ The foregoing instrument was acknowledged before me this 31 day of ne,To0Ea, 20 11 , by r1Ai -. K l &uTc t 1. So x> who is rsonally known to me �r who has produced As identification and who did take an oath. NOTARY PUBLIC: Signature Contractor The foregoing instrument was acknowledged before me this Si , day off.').. o3�IZ ,20 11,byg e-4RAND e.a6Bk i4 who is personally known to me or who has produced !} L- / tF6 ? 4)-jLf7D(42identification and who did take an oath. NOTARY PUBL C: My Commission Expires: Structural Review (Revised 07 /10 /07)(Revised 06/10/2009)(Revised 3/15/09) Sign: Print: My Commission Expires Zoning Clerk 0----Oct. 26. 2011 22:22FMS 3E4)1 13W 107 Alma Muni, 1$3185 R.O. Pima (30)2263000 excellence insurance brokers inc;A E AsAfNo.5915 000. 1,- COLT AND ONWEI6193 1 PiS UP= THE CERTIFICATE R,IIHSCIERTIFICATE DOES =MAMBA OR Fax MOVERS AFRMOING COVERAGE NA= ft MUM Contmotion & Inuestemals Inc Ricaido A. Cabo* 12700 SIN 40tt Street t , FL 33175 COVERAGES Olt of Landon Affitsica C: )0 d vasumta INSURBtF: ANYDEQUIREME41:113011ORCONDMON Of ANY CONTRACT MOTHER DOCIBENTINIM RESPECTTOINFICH ;SCEFDIFICAIE NAY RE OR NAYPERTAD.IKE INSURAHCEAFFORDED BYTISPOUCIESEESCRUIWIIRIBN SUBJEGMAILTHETERAIS. EXCLUSIMAND =DM= WINCE MMES. WE 1MMO=WAY OY PAID CiAlka A sErmisLussartY ® mr 00cxAS owst 0 D b]r Powf0Pismer Ouac -, 0 o AttiAlff0 • SCHIMULED AIMS #1111E0AUTOS ONNEDAUTOS 0 0 0 0427193784 03103111 X12 EACH OCCURRENGE lai/uumiiiiau 100,000.00 *MOO 1 ACCIA0.00 DAMAGETO REAM PREMISEMESocaiTaticei ME, PEBRONAL SAW INWELY 07127/11 1 01127I12 PRODUCT AG 2.000010.00, COVEDIED MOLE MIT (Ea awidenD 1,9,100 -00 IMFDILY ( BOINLY PROPS 1Yi GANNEUASIMY O AMAINro 0 83710 EAACCIDEAT OMERTIINi AUTO OM.Y EAA PSG EXCIMUNIDDELIA UMW! 0 OIMLIR 0 CLABASMADE 1dsalmon $ MOH OCCURRENCE ATE ,s, w l Nyeg, &softie va tSAMIH. MOM= bed= MUM 334000512345111 09112111 1 09112112 ICCILEL ERC1UA IENT ELO - EAR EL -PO= 11O; LM) 1 x,000.00, / I:00MM litOMX139 SIDDILUSIONS AWED 0% !»l CERTIFICATE HOLDER IS ADDITIONAL INSURED 1 CSTTINCATE INRDER L__ AGGRO 25 ovum OF . SWIM Wags 1000 NE2AVE NEW Shoren, FL 33138 FAX -772 CANCELLAT =MAU= DATE INERECW,ESSUMG D10110511111101. EMECNOR TO UAL DAYSIDIDTDDINCMCE101HE COMMIE HOLUM NAMIMID % TODOSOSHAM PN) CRUGABUN on WOW CO MM= VHIMI !iS = 4288 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER (305) 762.4949 L7EVMWMiN DEC 032010 Ni BY: BUILDING Permit No. V\IS 10 � 144 PERMIT APPLICATION Master Permit No. FBC 20 Permit Type: BUILDING OWNER: Name (Fee Simple Titleholder): in/H2!C tl fd 1*- �4 I V. p Xi Phone#: (IV 677 Address: / 0 C 9 CR S+ city: h') IPrtn ► '1 fic.e s State: P L Zip: 3 t Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: 10 LH IV e 9 Ce L City: Miami Shores County: Miami Dade Zip: 3 / e Folio/Parcel#: // co 0 / 7 Z0 Is the Building Historically Designated: Yes NO ` Flood Zone: CONTRACTOR: Company Name: Re C v$7 7. L 4 0 4- -tilt/bairn txt Phone#: 319'r) q7 t 4/ T' VICITY Address: / 2 7 0 0 Se S74 City: /V /947/ State: F-L- Qualifier Name: P/ C4,z 042 C7 9 L - Phone#: State Certification or Registration #: C 0 S .327 Certificate of Competency #: Contact Phone#: - U -0171= L P (O Email Address: DESIGNER Architect/Engineer: Phone#: Value of Work for this Permit: $ >I t 0?) ( 0 0 Square/Linear Footage of Work: 4t& Type of Work: OAddress OAlteration JJ ONew ORepair/Repl ODemolition Description of Work: ! �7-/ ,0 �/ a ��= S / "i Ai e� QS C3J r.4.1 rte/ &h 1i+ .. s 0 T,HROUGH ROOF TILE ISREQUIRED adrnowledged by: 1 f1 ********* * * ****** ** *** * * *•* * ** *** ** * ***F *** ********* ********* **** *** **** * ***** ***** Submittal Fee $ Permit Fee $ lo CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condmPon to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a c opy of the recorded notice of commencement must be posted at the job site for the first inspection hick occurs seve , v , s after the building permit is issued In the absence of such posted notice, the inspection will not b ap ed inspection fee will be charged Signature V er or Agent Signature pr, Contractor The foregoing instrument was acknowledged before me this gee; The foregoing instrument was acknowledged before me this °d 9 N day of f �l 0g1c3/ E 220 c 0, by OWL' /41)1t4i Nso /J , day of AIM err 8 E n , 20 /6 by et c4-1211-0 C L /.e,z4- who is personally known to me or who has produced who is personally known to me or who has produced FL fl L-14 As identification and who did take an oath. e.l *794 470 J'i as identification and who did take an oath. NOTARY PUBLIC: NOTARY P Sign: Print: LIC: My Commission Expires: APPROVED BY My Commission * * * * * * * * * * * * * * * * * * * * ** Plans Examiner Zoning Structural Review Clerk (Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09Xrev6/4/10) MIAMI -DADE COUNTY TAX COLLECTOR 140 W. FLAGLER ST. 1st FLOOR MIAMI, FL 33130 2010 LOCAL BUSINESS TAX RECEIPT 2011 MIAMI-DADE COUNTY - STATE OF FLORIDA EXPIRES SEPT. 30, 2011 MUST BE DISPLAYED AT PLACE OF BUSINESS PURSUANT TO COUNTY CODE CHAPTER BA - ART. 9 & 10 THIS IS NOT A BILL. - DO NOT PAY 527331 -3 BUSINESS NAME / LOCATION R C CONSTRUCTION & INVESTMENTS INC 12700 BIRD RD 33175 UNIN DADE COUNTY OWNER R C CONSTRUCTION & INVEST INC SBo. Type of Business 196 GENERAL BUILDING CONTRACTOR THIS IS ONLY A LOCAL BUSINESS TAX RECEIPT. IT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING LAWS OF THE COUNTY OR cram. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. TIES IS NOT A CERTIFICATION OF THE HOLDER'S QUAUFICA- PAYMENTRECBVED MIAMI-OAOE COUNTY TAX COLLECTOR 07/19/2010 02280057001 000075.00 SEE OTHER SIDE RENEWAL RECEIPT NO. 295270 -4 STATE# CGC054329 FIRST- CLASS U.S. POSTAGE I, PAID MIAMI, FL PERMIT NO. 231 WORKER /S 1 DO NOT FORWARD R C CONSTRUCTION & INVESTMENTS INC RICARDO CABRERA PRES 1408 BRICKELL BAY DR 815 MIAMI FL 33131 t► 1111►► 11►►►► il,► li, I ►►li►Ili►►III,,li ►ll►,►►,ll,i, 41 AIl IS CERTIFIED' under the provisions of Ch. 489 L'!3 sxplrsuog onto' A11G`- 31, _. 2012 L300003.01535 ALEX SINK CPUEF FMMACIAL 0FPI ER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELEieTION TO BE EXEMPT FROM FLORIDA maim COMAPERHUMNAM LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. 03 -06 -2009 EFFECTIVE DATE: PERSON: FEIN: 03/0612009 EXPIRATION DATE 0310612011 CABRERA RICARDO A 681188084 BUSINESS NAME AND ADDRESS: R C CONSTRUCTION & INVESTMENTS INC 12700 SW 40TH STREET MIAMI FL 33178 SCOPES OF BUSINESS OR TRADE: 1- CERTIFIED GENERAL CONTRACTOR IMPOBTAHT: Puissant to Chapter 440. O584L 1.5., in officer at a corporation who elects exemption from this droplet by filiag e certificate of *fettles seder ibis section may sot recover benefits to compsnspies under this Ibeptar. Pursuant to Chapter 440.081121, F.S., Certificates at election to he exempt... apply only within the scope of the baseness or wade listed ea the notice of electing to be exempt. Persson; to Chapter 440.05(13), 1.8., Notices of 81ecti0e to be exempt aid certificates el election to be exempt shell be subject to revocation it, a say tires after Me Meg of the notice at the iswuce of the certificate, the parses noted as the Mice or :ertificite no longer meets the requOemees of this section for isaa1ce of a certificate. The depatmeet stall revoke a.certilieate et my time for taltme of the person seated on die certificate to mat eat reedrema85 of this section. QUESTIONS? (860) 413 -1609 nleir. -1S9 cERTIFICATE OF ELECTION TO BE EXEMPT REVISED 09-06 CERTIFICATE OF LIABILITY INSURANCE ( DATE 1212110 . PRODUCER Excellence Insurance Agency 3801 SW 107 Avenue Mimi, FL 33165 Phone (305)226-3900 Fax (305)226 -3997 THIS CERTIFICATE 16 ISSUED AS A MATTER OF INFORMATION UPON THE CERTIFICATE ONLY AND CONFERS NO HOLDER. THIS CERTIFICATE DOS NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAIC # INSURED R.C. Construction & Investments Inc Ricardo A. Cabrera 12700 SW 40th Street i MIami„ FL 33175 INSURER A: Liolfds of London INSURER e: PROGRESSIVE AMERICAN INSURAN INSURER C: INSURER D: INSURER E COVERAGES INSURER F: THE POLICIES OF INSURANCE LISTED HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES. AGGREGATE MRS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. R t,. A AO-i4 i.�� ! ® TYPE OF INSURANCE GENERAL LIABt#.1TY p COMMERCIAi GENERAL LIAeILITY POLICY NUMBER FPRHI-I POIJGY.., .. EFFECTIVE DATE :, • �: 08/03/10 pOm , :.IRAIiON DATE •L' & LIMITS 08!03/11 EACH OCCURRENCE 1,000,000 PR .' GE PREMISES (' D PRBwISES (Ea oaauertas) 100,000 • • ❑ GEN'L ® • CLAIMS MADE ®aCCtAi MED EXP (Any Cite person) 5,000 PERSONAL &ADV INJURY 1,000,000 GENERALAGGREGATE 2,000,000 PRODUCTS - COMPIOP AGO 2,000,000 AGGREGATE Lf(�Il APPLIES PEfi POLICY ❑ PROJECT ❑ LCD B ❑ • ❑ 1 5 n Q • ANYAIJTO B� ALL OWNED AUTOS SCHEDUL ®AUTOS AIRED AUTa3 NONOWNEDAUTOS 0427587& 07127/11 01/27/11 COQ SINGLE LIMIT (Ea accident) BODILY INJURY meson) BODILY INJURY (Per cn9 PROPERTY DAMAGE (Per =Mere) AUTO ONLY- EA ACCIDENT • Lurr [] OTHER THAN EA ACC ANY AUTO • AUTO ONLY: AGO • EXCESSIUMBRELLA LIABIJTY ❑ OCCUR ❑ CLAIMS MADE • DEDUCTIBLE EACH OCCURRENCE AGGREGATE • RETENTION S WORKERS COMPENSATION AND EMPLOYERS' LJABILTRI ANY PROPRIETOR! PARTNER /EXECUTIVE OFFICER i MEAGER EXCLUDED? 11yes, des gibe under SPECIAL PROVISIONS blow • - ❑ OTH- D i4 3,.LJlr• ;, E.L. EACHACCiDENT E.L DISEASE - EA EMPLOYEE E.L DISEASE - POUCYLIAIT OTHER DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT! SPECIAL PROVISIONS CERTIFICATE HOLDER IS ADDITIONAL INSURED --,r , ,, --"' / CERTIFICATE HOLDER ACORD 25 (200110 QF OACORD CORPORATION 1988 • 1111111111111111111111111111111111111111111 CFN 2010R059520 OR Bk 27407 FAA 2308 — 2309; (2pss) RECORDED 09/02/2010 087008 DEED . DOC TAX 2,565.00 HARVEY RUVItI r CLERK OF COURT t9IAMI —DARE CDUHTY: FLORIDA Erie van der Vhtgt, Esq. Vice President Char Title Services, Ise. 1111 Kane Concourse Suite 209 Bay Harbor Islands, FL 33154 305465-5718 File Nombre: 10-0406 Hutchin Will Cali No.: _spm Above This Llne For Reco diagDatal Warranty Deed This Warranty heed made this 23rd day of Amt: 2010 between Clara Ian Washington, Individually and as Trustee(s) of the Clara Isom Washington Revocable Trams under Agreement dated 4/19/1988 whose post office address is 98 -10941 Soma Mai Dr, C/O Carla Usstato, Atom, III 96701, grantor, and Mark Hitebinson, a rdugh man where post office address is 1041 NE 96 St , MlawI Shores, FL 33138, gas (Whenever and hada the assn Wise amt "tee laduak all the pots to fhb imams& and the hair. legal nausteutativta, and assigns of nd MIduals, and the sum and assigns ofcotpotatiams, bob and halal) WitneseeHy that said pinks, for and in of the sum of TEN AND NO/100 DOLLARS ($10.00) and ear good and valuable considerations to said tip in hand paid by said puttee, the receipt whereof is hereby has granted, barpined, and sold to the maid grantee, and grantee's heirs and assigns forever, the following destaibed land, situate, lying and being in Mond -Dade County, Florida to-wit: Lot 14 AND THE EAST 112 OF LOT 15, in Black 82, OF MIAMI SHORES, according to the Plat thereof, recorded in Plat Book 10, Page 37, of the Public Records of Mlamt-Dade County, Florida Parcel Identification Number: 11-3206-014-3720 SUBJECT TO: 1) Taxes for the year 2010 and subsequent years and all applcabhe zoning ordinances and governmental regulations. 2) Conditions, rwstrlefions, limitations, and easements of record, if any, bat without the rote ntlont of reimposing same. Together with all the tenements, herulitaments and appurtemumes the belongingor in anywise appertaining. To Have and to Hold, the same in fee shnple forever. And the grantor hereby covenants with said gram that the granter is lawfully seized of said land in fee simple; that the minter has good right and lawful authority to sell and convey add land; that IBe gaunter hereby Slily water the title to said land and will defend the same against the lawful cams of all persons , and that said land is free of all except taxes accruing subsequent to December 31, 2009. In Witness Wkte>leoX grantor has hereuue° !gag's hmtdand seal the day and year fast above =item. Doublonnee Book27407 /Page2308 CFN #20100595201 Page 1 of 2 State ofFlorida County of Mlami-Dade OR BK 27407 PG 2309 LAST PAGE • 1 t 2I sw.- 9 v Clara Isabelle Washington, Tree lndlvidaally The foregoing instillment was acknowledged bets me this 20th day of � + and Individually, who U is known or [j has produced a + f [Notary Stall Printed Name: by Clara Isabelle Wes, Trustee identification. My Commission Espires: Waffarry Deed - Page 2 Doublellmse Book27407/Page2309 CFN#20100595201 Page 2 of.2 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO1 t11-,I2 IO "a/ TAX FOLIO NO. /f-20&2(2 f 437 2.0 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 111111111111111111111111111111111111111111111 CFN 201080826152 OR Bk 27516 Ps 0037; (1Ps) RECORDED 12/09/2010 15130 :0E HARVEY RUVIN, CLERK OF COURT MIAMI -DADE COUNTY, FLORIDA LAST PAGE 1. Legal description of property and street/address: /0 T ( N E '% S7 /2 / ,Zv29 / 2. 9escription of improvement: deP n 3. Owner(s) name and dddres,s. 1041 kg ' 1, S 122. /z h v ci.vus,},c) Imimv interest in property: O W /U P-1Z. 3 t 3 S Name and address of fee simple titleholder: 4. Contractor's name and address: 1' e. ac iu sI w mac. -A, t/ /Y7 ea s. 5. Surety: (Payment bond required by owner from contractor, if any) STATE OF FLORIDA, C� OF DARE HEREBY CERTIFY that this • copy of the Name and address: Amount of bond $ 6. Lender's name and address: WITNESS my HARVEY BY ' ,AD20 d and Official Seal. • VIN, LERK,e.f Cir u and County Courts W /4`' i d:sa D.C. PNp COU,1 CIE 9 01 GO➢10001005?.' cou 7. Persons within the state of Florida designated by Owner upon whom notices or of r documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 44 A- 9. Expiration date of this Notice of Commencement: the piration date is 1 year from the date of recording unless a different dat i, s• = ified) 3ignatu Print Owner's Name lC` f1 / 9/ A/ u ` Prepared by 14 Sworn to and subscribed before me this f day of 1�ec b , 20 Notary Public Print Notary's N My commission expires: Address: 2 9 70 .11, uJ. 7'54/e._ G 33.13 123.01 -52 PAGE 4 12/05 . EXP1REB:Ockeste,2011 _ 1. Client 2. Job Name 3. Job Address 4. County A1- Farooq Corporation 1235 SW 87th Avenue • Miami, FL 33174 Tel: (305) 264 -8100 • Fax: (305) 262 -6978 Site Specific: Wind Loads (Based on data supplied by client) R c ,v /rzvc, o 4 .) tii e#471e,f,74 , ti q. fY)4 f k v 7"c i/,vS o ,t) pc. u/2zl2ai0 Aye io -Vov HM /�A 5. Building Height : / 5 ft. (see sketch below) 6. Basic Wind Speed : / 44P mph 7. Wind Standard : ASCE 7 -05, FBC 2007 Edition 8. Roof Slope : ° Flat Slope: Pitch / 12 9. Exposure : Non Coastal ° Coastal ° Other (Coastal exposure applies within 1500 ft of ocean line or 50 miles within Std. Bldg. Code Chapter 16.) 10. Building : Length G> e ft. Width SQ ft. 11. Attach floor plan with shutter / window, sizes and types. (Note: If maximum load used for all openings floor plan is not required) 12. Building Category : tj-( Ultavrt /27,912c 78G- 3`x°1 -Z3 C2 Client Representative P8 4 1 i l4q- JA VAD AHMAD. F.E. - FL # 70592 EB C.A.T. #3538 r line foq 1 SUBJECT TO COMPLIANCE WITH AU STATE AND COUNTY RULES AND RE i !BLDG DEPT JA VAD AHMAD. F.E. - FL # 70592 EB C.A.T. #3538 AL- FAROOQ CORPORATION CAN (EB) #3538 1235 S.W. 87th. AVENUE MIAMI, FL. 33174 PH. 305 - 264 -8100 CUSTOMER :RC CONSTRUCTION & INVESTMENT PROJECT :MARK ('UTCHISON WIND LOAD ANALYSIS FOR COMPONENTS AND CLADDING AS PER SPECIFICATION ASCE 7 -05 BUILDINGS WITH IMPACT PROTECTION BASIC WIND SPEED V : 146 MPH IMPORTANCE FACTOR I : 1 EXPOSURE CATEGORY : C MEAN ROOF ELEVATION H : 13 FT. TRIBUTARY LOAD AREA A : 10 FT-2 Kh = 0.85 Kd = 0.85 Kzt= 1.0 11 -22 -2010 (TABLE 6 -3, PAGE 79) (TABLE 6 -4, PAGE 80) (TOPOGRAPHIC FACTOR - FIGURE 6 -4, PAGE 45) VELOCITY PRESSURE Qh= .00256 Kh Kzt Kd IV ^2 = 39.43 PSF GCp COEFFICIENTS (FIGURE 6 -11A, PAGE 55) ZONE 4 = +1.00 -1.10 ZONE 5 = +1.00 -1.40 GCpi COEFFICIENTS = + .18 - .18 (FIGURE 6 -5 PAGE 47) DESIGN PRESSURE P = Qh(GCp - GCpi) ZONE 4 = + 46.5 PSF - 50.5 PSF ZONE 5 = + 46.5 PSF - 62.3 PSF • •• ••• • • • • • •• • • • • • • • • •• ••• •• • • • •• • ••• ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • . ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • • • OA 14 N� � CIA 37x op' VP vL C� b . P-Roic4 Ltd io01 So .04. ! 7 2:'1,$0'' ' $4, I r t • le le' S < /2 /pc S , 16S 1,7 p —30490/ Sr-1746-5'R Wit &'Ri6 =s '' loo Cog )(72 1-99 0,epo 0Y o -A (aj "4 cam" ?,c 0V O't C CJJdQd • • • • •• • •. •••• • • •••• • • •• •• • • • • • •• • . S5• •• • .. • 1ps:3a g • 04.Q.ctreG • • ;• • •: oicroyo g MIAMlCADE COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) R.C. Aluminum Industries, Inc. 2805 NW 75th Avenue Miami, FL 33122 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.miamidade.aov/buildingcode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "HR100" Aluminum Horizontal Sliding Window — L.M.L APPROVAL DOCUMENT: Drawing No. W04-36, titled "HR100 Alum. Horiz. Sliding Wdw. (L.M.I.) ", sheets 1 through 6 of 6, dated 05/04/04 with revision "D" dated 07/08/10, prepared by AI- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distarbut&sarid shy beliillrie for inspection J request of the Building Official. �� NOAr inspection at the job site at the This inabl� 4 #X03.04 and consists of this page 1, Evidence pages E -1, E -2, E -3, and Green page 0-1, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. • ••• •• • • ••• ••• • • • • • • • • • • • • • • • • ..• • • • • .•• • • • • • • • • • • ••• • • • • • • • • • • • •• • •• • • • • ••• • • • ••• • • • • • • • • • •. •• NOA No. 10-0426.10 Expiration Date: August 05, 2014 Approval Date: August 04, 2010 Page 1 R.C. Aluminum Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W04-36, Sheets 1 through 6 of 6, titled "HR100 Alum. Horiz. Sliding Wdw. (L.M.I.) ", dated 05/04/04 with revision D dated 07/08/10, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmed, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Kinetic Energy Drop Load Test (400 Ft. Lb.), per ANSI Z97.1 along with marked -up drawings and installation diagram of an outswing aluminum Casement window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -6078, dated 12/05/09, signed and sealed by Julio E. Gonzalez, P.E. 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of an aluminum sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. AETI- 034881, dated 03/19/04, signed and sealed by Rafael E. Droz -Seda, P.E. (Submitted under previous NOA #06- 1130.02) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202 -94 along with marked -up drawings and installation diagram of aluminum sliding window, window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI -03 -1362, dated 12/11/03, signed and sealed by Rafael E. Droz -Seda, P.E. (Submitted under previous NOA #06-1130.02) 4. Test reports on: 1) Large. Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked-up drawings and installation diagram of an aluminum sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI -03 -1880, dated 12/12/03, signed and sealed by Rafael E. Droz -Seda, P.E. (Submitted under previous NOA #06-1130.02) 5. Tensile Test prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI -04 -T119, dated 04/23/04, tested per ASTM -E 8 -01e1, signed and sealed by . •...: R fae1 E :Droz-Seda, P.E. • • • •; Ag4ditdgr previous NOA #06- 1130.02) •• ••• •• • • • •• • ..• •.. • •.. •.. • • • • • • • • • • • • • • • • • • • • • • • • • • •. • • • • • • .. • • ••• • • • .. ••• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • •• ••• • • • • ... • • E -1 P.E. Product Co trot E : miner NOA i 426.10 Expiration Date: August 05, 2014 Approval Date: August 04, 2010 R.C. Aluminum Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2007, prepared by A1- Farooq Corporation, dated 02/09/10, signed and sealed by Javad Ahmad, P.E. Complies with ASTM E1300 -04 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 09 -0312.03 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Sentry Glass® Interlayer" dated 05/13/09, expiring on 01/14/12. 2. Notice of Acceptance No. 05- 1208.02 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite PVB Interlayer" dated 01/05/06, expiring on 12/11/10. F. STATEMENTS 1. Statement letter of conformance and no financial interest, dated March 09, 2010, signed and sealed by Javad Ahmad, P.E. 2. Proposal # 08 -1635 issued by BCCO to R.C. Aluminum Industries, Inc., dated 11/24/08, signed by Renzo Narciso, Engineer 1, Product Control Division. G. OTHER 1. Notice of Acceptance No. 09 -0303.04, issued to RC. Aluminum Industries, Inc. for their Series "HR100" Aluminum Horizontal Sliding Window — L.M.I., approved on 06/17/09 and expiring on 08/05/14. 2. Simulation Performance, Solar Heat Gain Coefficient Visible Transmittance, & Condensation Resistance Calculation Report on: 1) NFRC 100 -2004 "Procedure for Determining Fenestration Product U- Factors" 2) NFRC 200 -2004 "Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence" 3) NFRC 500 -2004 "Procedure for Determining Fenestration Product Condensation Resistance Values" Using computer simulation in accordance with NFRC: Frame and Edge Modeling: THERM 5.x, / WINDOW 5.x NFRC Simulation Manual (Approved at test date), of a RC Aluminum's "HR100" Horizontal Slider, along with attached drawings and bill of materials included in Appendix A, marked -up by National Certified Testing Laboratories, Test Report No. NCTL- 110 - 12455.01, pages 1 through 7 of 7, dated • • • • • 11/16/09, signed by Richard A. McVicker III, Simulator, and Steven H. Coble, NFRC A4cotiite1 Sinatdator, Simulator-In-Responsible-Charge. • • . •• ••• •• • • • •• • • •• •.. • ••• ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • .. . • • • • • • •• • .•• • • • • • • • • • •• • ••• • • • ••• • • • • • • • ••• • • • • • •• • • • • • • •• •• • ••• • • E -2 Manuel Per Product Control E NOA No. 1 Espiratlon Date: August 0S, 2014 Approval Date: August 04, 2010 R.C. Aluminum Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. NFRC 102 -2004 Thermal Performance Test Report on: 1) NFRC 102 -2004 "Test Procedure for Measuring the Steady State Thermal Transmittance of Fenestration Systems" Test report of a series RC Aluminum's Series "HR100" Type XO Horizontal Sliding Aluminum Prime Window with Low E and Argon, along with submittal component drawings, with applicable part numbers, manufacturing and modeling details included in Appendix A, marked -up by National Certified Testing Laboratories, Test Report No. NCTL - 110 - 12456 -1, pages 1 through 4 of 4, dated 11/20/09, signed by Christian J. Mitchell, Technician, and Robert H. Zeiders, P.E., Vice - President Engineering & Quality Person-In-Responsible Charge. 4. Recycled Content Determination Report on: Name: Horizontal Roller Window, HR100 Raw Material- Aluminum Including letter from Fundiciones Industriales S.A. (FISA) dated March 22, 2010, certifying that the extruded aluminum products contained 30% recycled scrap material, signed by Henry Kronfle, Vice- President. • •...... • .. .. • • • . • • • • •• •.• .• • • • •• • • • • • •. • •• • • • •. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • .. ...• • • •. • • • • ••• • • • • • • . • . • .. • ••• • • • ••• • • • • • • • •.• • • • • • • • • • • • • • • • • • • ••• • • E -3 Manu Product Control NOA No. 11 I 0 Expiration Date: August 05, 2014 Approval Date: August 04, 2010 R.C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED GREEN SUSTAINABLE ATTRIBUTES (GSA) SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division. Component Name 1. Window Aluminum % Recvcted Content at MenuL % Recycled at Disposal % Bio -based Material % Renewable Material 30% 100% N/A N/A 1. 2. 3. 4. Base line Product NCTL 110- 12456-1 000 001 002 Glazing Components: 5/32 CLR 240#2 -SS -D ARG BRZ- 1/8090 PVB 1/8 5/32 CLR 240 #2 -SS-D ARG BRZ -1/8 090 PVB 1/8 5/32 CLR 240#2 -SS-D ARG CLR -I /8 090 PVB 1/8 003 004 5/32 CLR 240#2 -SS -D ARG GRN -1/8 090 PVB 1/8 5/32 CLR 240#2 -SS -D ARG GRY -1/8 090 PVB 1/8 G.8: U- Factor 0.65 0.65 0.65 0.65 0.65 G.9: SHGC VT CR 0.20 021 15 020 0.21 15 021 0.28 15 020 0.19 15 026 0.26 15 end Abrevia 'on: Descri i +'on: SS-D Desiccant-Filled Stainless Steel Spacer 240#2 Cardinal Low E 240 @ #2 Surface Typical ARG 90% Argon PVB .090" Poly Vinyl Butyral (PVB) interlayer CLR Clear Glass BRZ Bronze Tint Glass GRN Green Tint Glass GRY Gray Tint Glass Component Name C -Value 1. Wbol.Window • • 1.53.. • • - • • . - • • • • • • • •• •.• •. • • • .. • ••• ••• • •• *•..• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •. • • • • • • •. • • ... • • • • ••• • • • • • • • • • • • • • • .•• • • • • • • • • • • • • • • • • •• • •. • • • • • • • • • • ••• • • • ••• • • G -1 Manuel Pe Product Control E - ml r NOA No.1 10 Expiration Date: August 05, 2014 Approval Date: August 04, 2010 } BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT•CONTROL DIVISION NOTICE OF ACCEPTANCE OA) R.0 :Aluminum Industries, Inc. • 2805 N.W. 75th Avenue Miami, FL 33122 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not .be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building . . Code, including the High Velocity Hurricane Zone. DESCRIPTION,: Series "fP3060" Aluminum Window Wall System — L.M L APPROVAL DOCUMENT: Drawing No. W03 -108, titled "HP3060 Alum. Window Wall System (L.M.L) ", sheets 1 through 9 of 9, dated 12/01 /03 with revision "C" dated 02/10 /09, prepared by Al-Farooq Corporation, signed and sealed by Humayoun Farooq, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING Each unit shall bear•a permanent label with the manufacturer's name or logo, city, state and following statement: " Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, ton it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distn�'uio$s find §halt bE sylable for inspection at the job site at the request of the Building Official. s 1OP: rivl'se$ a v re?hews NOA # 05- 0815.04 consists of this page 1 and evidence pages E -1 and E-2, MIAMI DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 wiww.miamidade..ov/buildinEcode kS welt us approval Iou ume&t mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. -• ••• • • •.. ••. .. • • • • • • • • • • • • • • • • • • • • • • • • . •• • • • • • • • G1.10_ylr.712 illlixU 'APPROVED' ••• • • • • •.• • • • • • • • • • • • • • ••. • • • • • • • • • • • •• • • • • ••. • • • • • ••• • • • • • • • • • • • • • NOA No. 09- 0324.01 Expiration Date: April01, 2014 Approval Date: May 27, 2009 Page 1 R.C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W03 -108, Sheets 1 through 9 of 9, titled "HP3060 Alum. Window Wall System (LM[) ", dated 12/01 /03 with revision "C" dated 02/10/09 prepared by Al- Farooq Corporation, signed and sealed by Humayoun Farooq, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC,TAS202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact-Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 • along with marked-up drawings and installation diagram of an aluminum window wall system, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -5739, dated 11/14/08, signed and sealed by Carlos S. Rionda, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 • 2) Uniform Static Air Pressure Test, Loading per FBC,TAS202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked up drawings and installation diagram of an aluminum window wall system, prepared by Fenestration Testing Laboratory, Inc., Test Report No FTL -2993, dated 03/19/01, signed and sealed by Luis Antonio Figueredo, P.E. "Submitted under NOA # 05- 0815.04" 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 ) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 • 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of aluminum window wall system, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL- 2356, dated 07/19/99, signed and sealed by Edmundo.J. Largaespada, P.E. Submitted under NOA # 03- 1224.04" 4. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact.Test per FBC, TAS 201 -94 • • ••• • • ▪ • • • • 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 • • • • • 6) Forced Entry Resistance, per FBC 2411.3.2.1 and 7,02-94 •• •• • • • •• • • • • • • • • •• Product Control - , i , , er - • • • • • • • • • • • • • • • • NOA No. 09- 0324.01 • ▪ • • • • • • • • • Expiration Date: April 01, 2014 Approval Date: May 27, 2009 ••• • • • • ..• • • • • • • • • • • • ... • .. • • • • • • • .•••••• • • • ••• • •..• E -1 LC. Ahuninum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBNIITTED B. TESTS (corrriNvED) along with marked -up drawings and installation diagram of an aluminum window wall system, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -2618, dated 08/23 /00, signed and sealed by Edmundo J. Largaespada P.E. "Submitted under NW # 03- 1224.04" 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 . 4), Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of an aluminum window wall system, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -2172, dated 11/16/98, signed and sealed by Edmundo J. Largaespada, P.E. "Submitted under NOA # 03- 1224.04" C. . CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2007, prepared by A1- Farooq Corporation, dated 02/09 /09, signed and sealed by Humayoun Farooq, P.E. Complies with ASTM E1300 -02/04 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 09- 0312.03 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Sentry Glass® Interlayer" dated 05/13/09, expiring on 01/14/12. 2. Notice of Acceptance No. 09- 0211.05 issued to Viracon, Inc. for their "Viracon HRG-2 Glass Interlayers ", dated '03/25/09, expiring on 02/12/10. F. STATEMENTS 1. Statement letter of conformance, dated February 9s', 2009, signed and sealed by Humayoun Farooq, P.E. , 2. Statement letter of no financial interest, dated February 9`b, 2009, signed and sealed by Humayoun Farooq, P.E. 3. Laboratory compliance letter for Test Report no. FTL- 5739, issued by Fenestration Testing Laboratory, Inc., dated January 22, 2009, signed by Manny Sanchez G. OTHERS • 1. Notice of Acceptance No. 05- 0815.04, issued to R.C. Aluminum Industries, Inc. for • • •::.::tile* &cies "HP3060" Aluminum Window Wall System — L.M.I., a • , roved on • • • •; :: • :: 02/265061�ud expiring on 04/01/09. -.• .. •• • • • • • • • • • • • • • •• • ••• •• • • • • • •• • • • • • • .•• • • • • • • • • • • • •.• • • • • • • • • • •• •• • ••• • • • ••• • • • • • • • • • • • • • • •• •• ••• • • E -2 Product Con a " er NOA No. 09- 0324.01 F.xpiration Date: April 01, 2014 Approval Date: May 27, 2009 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) R. C. Aluminum Industries, Inc. 2805 NW 75th Ave Miami, FL 33122 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1107 MIAMI, FLORIDA 33130 -1563 (305) 375 -2902 FAX (305) 372 -6339 www.miamidade.gov/buildinscode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "RD45" Aluminum Entrance Door w/ wo Transom & Sidelites - L.M.I. APPROVAL DOCUMENT: Drawing No. W04 -37, titled "Series RD45 Alum Entrance Door (L.M.I.) ", sheets 1 through 10 of 10, dated 05/09/04 and last revised on 05/05/09, prepared by Al- Farooq Corporation, signed and sealed by Arshad Viqar, P. E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Mssr&e Impact Resistant LIMITATIONS: 1. Load bearing shim required. 2. Max 1/4" shim allowed for installation in steel substrate. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami-Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and fo}lowed by:th4e a tpirrti¢n•datee may be displayed in advertising literature. If any portion of the NOA is dispiayetll tiaeri itbhbil: dege in its entirety. I1 Pleb TJ1Q: A cdpybf this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. • Thist 4OA t s tiOA.Ne. 01•-0513.07 and consists of this page 1 and evidence pages E-1 and E-2, as • appmch, opgnq t• , v • 11 as at meahoned above. The ;Amittortd&*tment plbn ves reviewed by Jaime D. Gascon, P. E. APP "OY'DI •• • • • • • • • • • .• •• • • • ••• • • ••• • •• • NOA No. 09-0630.07 Expiration Date: August 19,2014 Approval Date: August 05, 2009 Page 1 R. C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W04 -37, titled "Series RD45 Alum Entrance Door (L.M.I.)", sheets 1 through 10 of 10, dated 05/09/04 and last revised on 05/05/09, prepared by Al Farooq Corporation, signed and sealed by Arshad Viqar, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202 -94 along with marked -up drawings and installation diagram of aluminum entrance door, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL -5390 dated February 18, 2008, signed and sealed by Carlos S. Rionda, P. E. (Submitted under previous NOA No. 08-0613.0 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 24113.2.1 and TAS 202 -94 along with marked-up drawings and installation diagram of aluminum entrance door, prepared by Fenestration Testing Laboratory, Inc., Test Reports No(s). FTL -4154, dated March 24, 2004, FTL -4155, dated March 30, 2004 and FTL -4166, dated March 31, 2004, signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No. 04-0608.03) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2004/ 2007, prepared by Al Farooq Corporation, dated May 29, 2008 and last revised on July 14, 2008, signed and sealed by Dr. Humayoun Farooq, P. E. Complies with ASTM E1300-02 D. QUALITY ASSURANCE • • • 1.• • • • Miami Dade Building Code Compliance Office (BCCO). • • . • • • • . • •• ••• •• • • • •• • ••• ••• • • • • • • • • • • • • • • • • • • .. • • . • • • • • • ••• • • • • • • • • • • • • • •• •• ••• • • ••• ••• • • • • • • • • • • • • ••• • • • • • • • • ••• • • • • • • • • • • • • •• •• •• ••• • • •• • E -1 Jaime D. Gascon,l'. E. Chief, Product Control Division NOA No. 09- 0630.07 • Expiration Date: August 19, 2014 Approval Date: August 05, 2009 R. C. Aluminum Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 09 -0312.02 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite® PVB, Interlayer" dated 05/13/09, expiring on 12/11/10. F. STATEMENTS 1. Statement letter of conformance, dated May 04, 2009, signed and sealed by Arshad Vigar, P. E. 2. Statement letter of no financial interest, dated May 04, 2009, signed and sealed by Arshad Vigar, P. E. 3. Statement letter of changes, dated May 04, 2009, signed and sealed by Arshad Vigar, P. E. 4. Laboratory compliance letter for Test Report No. FTL -5390, issued by Fenestration Testing Laboratory, Inc., dated February 18, 2008, signed and sealed by Carlos S. Rionda, P. E. (Submitted under previous NOA No. 08-0613.07) 5. Laboratory compliance letter for Test Report No.'s FTL -4154, FTL -4155 and FTL- 4166, issued by Fenestration Testing Laboratory, Inc., dated February 18, 2008, March 30, 2004 and March 31, 2004, signed and sealed by Edmund() Largaespada, P. E. (Submitted under previous NOA No. 04-0608.03) G. OTHERS 1. Notice of Acceptance No. 08- 0613.07, issued to R. C. Aluminum Industries, Inc. for their Series "RD45" Aluminum Entrance Door w/ wo Transom & Sidelites — L.M.I. ", approved on 09/04/08 and expiring on 08/19/09. • • •• • • • • •• • • • • •.i • • • •• ••• •• • • • •• • •• ••• • • • • • •• • • ••• • • • • • •. • • •• • • ••• • • •. • • • • • • • • • • • • • • • • • • • • •• • • • ••• • • • • • • ••• • • • ••• • • • • • • • .• • • •• •• • • • ••••i ••• • E -2 Jaime D. Gascon, P. E. Chief, Product Control Division NOA No. 09- 0630.07 Expiration Date: August 19, 2014 Approval Date: August 05, 2009 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) R.C. Aluminum Industries, Inc. 2805 NW 75s' Avenue Miami, FL 33122 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "FX100" Aluminum Fixed Window — L.M.I. APPROVAL DOCUMENT: Drawing No. W04 -44, titled "FX100 Aluminum Fixed Window (L.M.I.) ", sheets 1 through 5 of 5, dated 05/29 /04 with revision "F" dated 12/09 /09, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P E , bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large Motile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. Thig WO) ;aids KQk #9-0225.08 and consists of this page 1, Evidence pages E-1, E-2, E -3, and Green Susttl rab1 t p d-1, as well as approval document mentioned above. Thh §ub#dlttecl trocusier$aatioaoas reviewed by Manuel Perez, P.E. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.miamidade.eov/buildingcode NOA No. 10-0426.07 Expiration Date: August 19, 20.14 Approval Date: August 04, 2010 Page 1 R.C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W04 -44, Sheets 1 through 5 of 5, titled "FX100 Aluminum Fixed Window (L.M.I.), dated 05/29 /04 with revision F dated 12/09/09, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmed, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Kinetic Energy Drop Load Test (400 Ft. Lb.), per ANSI Z97.1 along with marked -up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -6043, dated 10/22/09, signed and sealed by Julio E. Gonzalez, P.E. 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 3) Kinetic Energy Drop Load Test (400 Ft. Lb.), per ANSI Z97.1 along with marked-up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -5866, dated 10/09/09, signed and sealed by Michael R. Wenzel, P.E. 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked-up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -4295, dated 10/08/04, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA# 05- 0815.01) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4294, dated 10/08/04, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA# 05-081 5.01) • •• ••: 1 • .•... •• ▪ •s• •• ••• • • •s ••• ••• ••• • • • • • • • • • •• • • • • • . • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••. • •• •• • ••• • • • ••• .• • • • • ••• • • • ••• • • • • • • • • • • . • • •• •• •.' E -1 uel ' _% P.E. Product Contro iner NOA No. 10-0426.07 Expiration Date: August 19, 2014 Approval Date: August 04, 2010 R.C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -4290, dated 08/16/04, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA# 05 -081 5.01) 6. Test reports on: 1) Mr Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FM-4293, dated 10/08/04, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA# 05- 0815.01) 7. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -4296, dated 10/08/04, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA# 05- 0815.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2007, prepared by Al- Farooq Corporation, dated 02/01/10, signed and sealed by Javad Ahmad, P.E. Complies with ASTM E1300 -04 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 09- 0312.03 issued to EL DuPont DeNemours & Co., Inc. for their "DuPont Sentry Glass® Interlayer" dated 05/13/09, expiring on 01/14/12. 2. Notice of Acceptance No. 05- 1208.02 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite PVB Interlayer" dated 01/05/06, expiring on 12/11/10. • •• ••• . . ••. . , •• • •n •i ••i i R.C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance and no financial interest, dated July 9, 2010, signed and sealed by Javad Ahmad, P.E. 2. Proposal # 08 -1635 issued by BCCO to R.C. Aluminum Industries, Inc., dated 11/24/08, signed by Renzo Narciso, Engineer 1, Product Control Division. G. OTHER 1. Notice of Acceptance No. 09 -0225.08, issued to R.C. Aluminum Industries, Inc. for their Series "FX100" Aluminum Fixed Window — L.M.I., approved on 05/27/09 and expiring on 08/19/14. 2. Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance, & Condensation Resistance Calculation Report on: 1) NFRC 100 - 2004 "Procedure for Determining Fenestration Product U- Factors" 2) NFRC 200 -2004 "Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence" 3) NFRC 500- 2004 "Procedure for Determining Fenestration Product Condensation Resistance Values" Using computer simulation in accordance with NFRC: Frame and Edge Modeling: THERM 5.x, / WINDOW 5.x NFRC Simulation Manual (Approved at test date), of a RC Aluminum Series "FX100" Fixed aluminum window, along with attached drawings and bill of materials included in Appendix A, marked -up by National Certified Testing Laboratories, Test Report No. NCTL -110- 12451.01, pages 1 through 7 of 7, dated 11/13/09, signed by Richard A. McVicker III, Simulator, and Steven H. Coble, NFRC Accredited Simulator, Simulator-In-Responsible-Charge. 3. NFRC 102 -2004 Thermal Performance Test Report on: 1) NFRC 102 -2004 "Test Procedure for Measuring the Steady State Thermal Transmittance of Fenestration Systems" Test report of a series "FX100" fixed lite aluminum prime window with Low E and Argon, along with submittal component drawings, with applicable part numbers, manufacturing and modeling details included in Appendix A, marked-up by National Certified Testing Laboratories, Test Report No. NCTL -110- 12352 -1, pages 1 through 4 of 4, dated 11/30/09, signed by Christian J. Mitchell, Technician, and Robert H. Zeiders, P.E., Vice - President Engineering & Quality Person-In-Responsible Charge. 4. Recycled Content Determination Report on: Name: Fixed Window, FX100 Raw Material: Aluminum Including letter from Fundiciones Industriales S.A. (FISA) dated March 22, 2010, certifying that the extruded aluminum products contained 30% recycled scrap material, signed by Henry Kronfle, Vice - President. • ....•.. • •• • • • •..... •., '. • oil. .: '.• : : •.' • •• •.. ... • • • • : • • ..• •so • • • • . • • • • ••• •• • : • : R.C. Aluminum Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED GREEN SUSTAINABLE ATTRIBUTES (GSA) SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction Materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division. Component Name % Recycled Content at ManuL % Recycled at Di____ANgd % Bio-based Material % Renewable Material 1. Window Aluminum 30% 100% N/A N/A 5/32 CLR 240#2 -SS -D ARG BRZ -1/8 L 090 PVB 1/8 5/32 CLR 240#2 -SS -D ARG CLR -1/8 090 PVB 1/8 5/32 CLR 240#2 -SS -D ARG GRN -1/8 090 PVB 1/8 Leeend Abreviation: t .. ri a • on: SS -D Desiccant - Filled Stainless Steel Spacer 240#2 Cardinal Low E 240 @ #2 Surface Typical ARG 90% Argon PVB .090" Poly Vinyl Butyral (PVB) interlayer CLR Clear Glass BRZ Bronze Tint Glass GRN Green Tint Glass GRY Gray Tint Glass Component Name C -Value 1. jv/hole Window .95 • • • . •-• .. •• •• • ••• • • • • • . • •• •••• • •.• ' • • ••••••• .•• ••• ••• • • . • . . • • ••• •• • • • • • • • • • ••. •• • . • • • • •• • • • • ••• •• • ••• • • • • • • • ••• • • • • ••• • • • • .•. •• •• • • • • • • • • • • ••• •' '• G -1 Manuel Per Product Control E NOA No.1 i . 7 Expiration Date: August 19, 2014 Approval Date: August 04, 2010 IMAMS COUNTY BUILDING CODE COMPLIANCE OFFICE (BC O) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) R. C. Aluminum Industries, Inc. 2805 N. W. 75d. Ave. Miami, FL 33122 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAMER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www=miam• sde novtbmfdhancode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Mani Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the - manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "ML 100" Almninum Tube Mullion ^ L.M.I. APPROVAL DOCUMENT: Drawing No. M04-05, titled "Ahmmimmm Tube Mullions ", sheets 1 through 7 of 7, dated 05/02/04 with revision "C" dated 09/22/08, prepared by Al Farooq Corporation, signed and sealed by Hwnayoun Farooq, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the marmfacturer's name or logo, city, state and following statement "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising of any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This•NQA retses and renews NOA 11 064130.03 and consists of this page 1 and evidence pages E -1 and E:2•, as willlts,cpprtvz5 &xwliient mentioned above. TlipsuliiittkilktuNtiatititur was reviewed by Manuel Perez, P.E. • • • ••• ••• • • • • • • • • • • • • • ••. • • • • •• •• • . • • • • ••• • • • • ••• •• ,• NOA No. 09-012814 Expiration Date: August 19, 2014 Approval Date: Apr$ 08, 2009 Page 1 R. C. Aluminum Industry, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No M04 -05, tided "Aluminum Tube Mullions", sheets 1 through 7 of 7, dated 05/02/04 with revision "C" dated 09/22/08, prepared by A1- Farooq Corporation, signed and sealed by Humayoun Farooq, P.E. B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with installation diagram of aluminum single hung windows mulled together, prepared by Fenestration Testing Laboratory, Inc., Test Report No.FTL -4024, dated January 14, 2004, signed and sealed by Edmundo Largaespada, P.E. (Submitted under previous NOA #04-060805) 2. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Large Missile Impact Test per FBC, TAS 201 -94 4) Forced Entry Test, per FBC 24113.2.1 (b) and TAS 202 -94 along with installation diagram of aluminum fixed and casement windows mulled together, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-03 -1346, dated September 16, 2003, signed and sealed by Rafael E. Droz -Seda, P.E. (Submitted under previous NOA #04- 060805) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 2004, prepared by Al -Farooq Corporation, dated 09/24/08, signed and sealed by Humayoun Farooq, P.E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. None • • • • •• •0 0 0 • • . • •• •. ••t '•• •• . • • •• ' ••• ••• • • • • • • • • ••• ••• • •.• •• • •• • • • • • • • • •• • • • ••• •' •.• .• E -1 Mangy P; a Product Control NOA No. 4 Expiration Date: August 19, 2014 Approval Date: April 09, 2099 R. C. Aluminum Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of compliance, dated September 16, 2008, signed and sealed by Humayoun Farooq, P.E. 2. Statement letter of no financial interest, dated October 06, 2006, signed and sealed by Humayoun Farooq, P.E. (Submitted under previous NOA #06- 1130.03) G. OTHERS 1. Notice of Acceptance No. 06- 1130.03, issued to R. C. Aluminum Industries, Inc. for their Series "Series "ML 100" Aluminum Tube Mullion — L.M.I. ", approved on 04/05/07 and expiring on 08/19/09. ....... • .. .. • . • • ▪ • • • . .. ... .. • .... • ••• ... • ...... .. • ... • • .. • • • • • • • • • • • • • • • • • • • • • • • • .. • • E -2 Manuel Product Control NOA No. 09-0 4 Expiration Date: August 19, 2014 Approval Date: April 08, 2009