EL-11-1590Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 163881 Scheduled Inspection Date: October 25, 2011 Inspector: Devaney, Michael Owner: DEL ALMO, RAMIRO Job Address: 9215 N BAYSHORE Drive Miami Shores, FL 33138- Permit Number: EL -8 -11 -1590 Project: <NONE> Contractor: AAJ ADVANCE ELECTRICAL CORP Permit Type: Electrical - Residential Inspection Type: Final Work Classification: Addition /Alteration Phone Number (305)772 -6820 Parcel Number 1132050270590 Building Department Comments UPGRADE ELECTRICAL SERVICE GFI AT MARINE AREA Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments >7Z__ October 24, 2011 For Inspections please call: (305)762 -4949 Pepe 5of21 00(-95' Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 - Permit No. BUILDING PERMIT APPLICATION FBC 20 Permit Type: Electrical OWNER: Name (Fee Simple Titleholder): Address: ?/ 5 a City: H% 19121 S '22.f Ligyv P.-i RECEIVED AUG '� 2011 BY: IA It9 Master Permit No. Phone #: 7g6 ..2 3 s d9 /5 State: P600 -444, Zip: '33/36 Tenant/Les ee Name: Phone #: Email: I i I' I I zD /b ade5I Yj? JOB ADDRESS: 9Z15 , 4 / le-ee City: Miami Shores County: Miami Dade 3/3S Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: �19C%� ,'�' JGt ��C. 14 'hone#: -31 ?c — ��� CONTRACTOR: Company Name: I _ X35 Sew Iz3 4 Address: City: Pit % ,,��--++ State: �+- � l'%-) Zip: 3.315 Qualifier Name: c7 s .'S ,¢t /—)t %a Phone #: State Certification or Registration #: Eg ®O /4 5? o Certificate of Competency #: V E'oat) Z53 Contact Phone #: 319 -UV 35 Email Address: DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ 4r 37 S, Square/Linear Footage of Work: Type of Work: ❑Address ❑Alteration ❑New ❑Repair/Replace ❑Demolition Description of Work: A.13— 00 / -T l9-r ii(d,'/f Are", _ raxpasasAaasasA3> Raw, axxAaaagxakikRRFR> FAaas* uxK * MAsFeesM************* MM*MMM** Mxx *. * . aA* Submittal Fee $ Permit Fee $ h ®t 66") CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ ' ^ y-� TOTAL FEE NOW DUE $ 1(.05 � Q Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and MR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant roust promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approv'd and a reinspection fee will be charged. Signature L___---Owner or Agent ent was acknowledged before me this°"c " • The fore: •'ng ins / day o lit ,, ii who is • • r , 20AL, by known to me or who has produced NOTARY P Sign: Print: My Commis As identification and who did take an oath. r " ry Public • State of Florida My Comm. Expires Feb 11, 2015 Commission # EE 56663 Bonded Through National Notary Assn. Signature Contractor The fore.' g instrume was acknowledged before me this®, day o'/ 1I 1. 4,20 /1,by who is pens• °11y to 33e o who has produced as identification and who did take an oath. NOTARY P, Sig Print: My Co IC: i E: 1 MV Comm. Expires Feb 11, 2015 res'Commission 0 EE 56663 „,,, . "' Bonded Through National Notary Assn. Aa$ax. 3asgsgsa>a3a3aAa3a39kakasRA < s:afa3aMx3a>g39sgsg3a>gaa. 3aRasa. 3aaR3a3ask3Yna $aka>asFXa3ssRspsp3939tlt. 9'. ****. aa. sg3c #TBaRfa. 39x. x3a3a3a3a3asAx. M3+ 3a> g3asg3a3a3a>a, js3a** *sF3ax3a3a••••••s83asasa>83aasi 3a3 APPROVED BY Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Zoning Clerk sip o 1 1011 AAJ ADVANCE ELECTRICAL CORP. �y®< 2035 SW 123CT. Miami, FI. 33175 "eI:(305) 221 -3201 Cell:(305)986 -0435 ... \ •......... •�1 1� C.C. No. 97E000253 511 MR: YVES LAMPERT ✓ \1 Job Address: 9215 N. BAY SHORE DRY MIAMI FLA 33138 ALL CONDUCTORS SIZED TO CARRY LOAD CALCULATED PER 220 ' THRU ROOF HEIGHT ABOVE ROOF -MIN 2' - MAX 38" 7 MU4 RISE 2" RIGID OK, fi CONDUIT: IMC 2" VARE 2;9THIAN '` AIL RATING (110.9) 20,000 OUTSIDE DISCONNECT— 0 CITY COPY ' CLEARANCES 239 -24 8 680-8 ' DRIP LOOPS 230-54 (F) MAN a) FUSE b) BREAKER c) DIST. PANEL ( 230 -PART F `1 1' PAIIEL A 1 THRU ROOF a) YES b) NO HOT TO CENTER OF METER (FPL)5'TO6' PANEL FEEDER a) NEW b) OLD CONDUIT 2" EMT C) EXISTING Vv1RE: 2.0 TI- AN Two Ground i or! 53 inch x 0 feed and one Grounding Elec. Conti * 4 250 -33 and 250 -94 NOTE: 1) COMPLY VAIN 250 -112 INHERE APPLICABLE 2) BOND BUSHINGS 250 -72 (D) 3) FPL REQUIRES METER 5' -6' ABOVE GRADE TO CENTER OF METER Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT /�,. / / ' ' V/w // SUf1,11 -CT TO COMPLIANCE WITH ALL FEDERAL S T A I I AM) COON FY RULES AND REGULATIONS AAJ ADVANCE ELECTRICAL CORP. 2035 SW 123C1'. Miami, Fl. 33175 Tel:(305) 221 -3201 Cell:(305)986 -0435 C.C. No. 97E000253 MR & Mrs: YVES LAMPERT Job Address: 9215 NORTH SHORE DRY MIAMI SHORES , FLA 33138 Panel (A) Circ. No Description of Load Volts Strip Wire Cond. 1,3 A/C FIRST FLOOR 240 40 2 # 8THW 3/a" 2,4 A/C SECOND FLOOR 240 40 2 # 8THW 34" 5,7 RANGE 240 50 2 # 6THW 3/4 " 6,8 SUB -MAIN 240 60 2 # 6THW 1" 9,11 LIGHTING \LAIN 240 60 10,12 LIGHTING MAIN 240 60 13 A- POOL SPOT B- G /LIGHTS MIDDLE ROOM 120 15 # 14THW 1/2" 14,16 COOK TOP 240 50 2 # 6THW 3/4" 15 A- G /LIGI -ITS B- G /LIGHTS 120 15 # 14THW '" 17 A- G /LIGHTS LAUNDRY B- G /LIGHTS GARAGE 120 15 # 14THW 1/2" 18 DISWASHER 120 20 # 12 THW '/2" 19 A- S /APPLIANCE B- S /APPLI.\NCE 120 20 # 12 THW 1/2" 20 G /LIGHTS 120 15 # 14 THW '" 21 G /Light 120 15 # 14 THW ' /2" 22,24 PUMP 240 20 # 20 THWN 1/2" 25 REFRIGERATOR 120 20 # 20 THWN 1/2" 26,28 DRYER 240 30 # 10 THWN ' /2" 27 A- G /LIGHTS B- TRAS COMP. 120 15 # 14 THWN ' /2" J.oad Calculation Living .Area 3,600' X3 2 Appliance (1500 Watts Each) Laundry (W /Machine) Refrigerator T- Compactor Disposal Dishwasher Microwave Wine Cooler Pool Motor Water Heater Dryer 10,800 Watts = 3,000 Watts = 1,500 Watts = 750 Watts 750 Watts = 000 Watts 750 Watts 1,000 Watts = 000 Watts 2800 Watts 13,800 Watts = 5,000 Watts Range = 12,000 Watts Total Demand Load = 52,150 Watts Electrical Panel OF 200 AMPS, 3 CU /W # 2/0 THWN First 10,000 Watts @100°0 = 10,000 Watts Remainder 36,540 Watts @ 40° o = 16,860 Watts 2- A/C 7.5 KW Sstrip HTR @100°0 = 15,000 Watts Total Connected Load= 41,860 Watts Total = 41,860 / 240V = 174,42 AMPS? `:' AAJ ADVANCE ELECTRICAL CORP. 2035 SW 123CT. Miami, FI. 33175 Tel:(305) 221 -3201 Cell:(305)986 -0435 C.C. No. 97E000253 MR & Mrs: YVES LAMPERT Job Address: 9215 NORTH SHORE DRY MIAMI SHORES , FLA 33138 SUB -PANEL "B" Circ. No Description of Load Volts Strip Wire Cond. 1 \-S/APPLIANCE B- OVEN 120 240 20 30 # 12 THWN # 10 TI-L N 1/2 " 1/2" 3 A -OVEN B- S /APPLIANCE _ 240 120 30 20 # 10 THWN # 12 THVM '/Z " 1/2' 2 G /LIGHTS 120 20 # 12 THW 1/2 " 4 G /LIGHTS 120 20 # 12 THW 1/2 " 5 A- G /LIGHTS B- SPA 120 120 20 20 # 12 THWN # 12 THWN 1/2" 1h" 6 SPACE 7 G /LIGHTS 120 20 # 12THW 1/2" 8 SPACE 9 G /LIGHTS 120 20 # 12THW 1/2" 10 SPACE 11 MICROWAVE 120 20 # 12 THWN 1/2" 12 SPACE Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. -1/ /6 VC Job Name AA"? e f 1 CRITIQiTE SHEET A '2 c"-- (R/),/ ',-- e� 11:17 AUG 24, 2011 FR: AMANDA #81706 PAGE: 1/1 ACORU® �..-- CERTIFICATE OF LIABILITY INSURANCE DATE (MMIDDIYYYY) 8/24/2011 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Eastern Insurance Group, Inc. 9570 SW 107 Avenue Suite 104 Miami FL 33176 - CONTACT David M. Lopez NAME: p i& N (305) 595-3323 (AIC,No: (305)595 -7135 .Ext): Appmcsr @easterninsurance.net PRODUCER 00002429 CUSTOMER ID 9: INSURER(S) AFFORDING COVERAGE NAIC it. INSURED AAJ Advance Electrical Corporation 2035 SW 123 Court Miami FL 33175 INSURERA Mid- Continent Casualty Company OCCUR INSURER 5 :CastlePoint Florida Insurance INSURER C : 5/20/2011 INSURER D : EACH OCCURRENCE INSURER E : DAMAGE TO PREMISES Ea occurrence) INSURER F : COVERAGES CERTIFICATE NUMBER:Master 11 -12 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR LTR TYPE OF INSURANCE ; • • INSR y81= - WVD POLICY NUMBER FFOLfCYEFF (MMIDDIYYYY) POLICYEXP (MMIDDNYYY) LIMITS A GENERAL X LIABILITY COMMERCIAL GENERAL LIABILITY X OCCUR 04— GL-000821316 5/20/2011 5/20/2012 EACH OCCURRENCE $ 1,000,000 DAMAGE TO PREMISES Ea occurrence) $ 100,000 CLAIMS -MADE MED EXP (Any one person) $ Excluded PERSONAL & ADV INJURY $ 1,000 , 000 GENERAL AGGREGATE $ 2,000,000 GE 'L AGGREGATE LIMIT APPLIES PER: - POLICY JECT LOC PRODUCTS- COMP /OP AGG $ 1,000,000 X $ AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ $ $ UMBRELLA LIAB EXCESS LIAR OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DEDUCTIBLE RETENTION $ $ $ B WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNERIEXECUTIVE OFFICE ER EXCLUDED? (Mandatory In In NH) If yes, describe under DESCRIPTION OF OPERATIONS YIN NIA NCP760326101 4/1/2011 4/1/2012 $ TORY LIMITS ER E.L. EACH ACCIDENT $ 100,000 E.L. DISEASE - EA EMPLOYEE $ 100,000 below E.L. DISEASE- POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS t VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space Is required) Residential Electrical contractor (305) 756 -8972 Miami Shores Village Building Department 10050 NE 2 Avenue Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE '__r> David Lopez /AMANDA —.-- ACORD 25 (2009109) NS025 (200909) - . . The ACORD name and logo are registered marks of ACORD 1 MIAMI -DADE COUNTY TAX COLLECTOR 140 W. FLAGLER ST. 1st FLOOR MIAMI, FL 33130 2011 LOCAL BUSINESS TAX RECEIPT 2012 MIAMI -DADE COUNTY - STATE OF FLORIDA EXPIRES SEPT. 30, 2012 MUST BE DISPLAYED AT PLACE OF BUSINESS PURSUANT TO COUNTY CODE CHAPTER 8A - ART. 9 & 10 THIS IS NOT A BILL — DO NOT PAY RENEWAL RECEIPT NO. 397959-9 CC B 97E000253 381143 -8 BUSINESS NAME / LOCATION AAJ ADVANCE ELECTRICAL CORP 3309 NW 74 AVE 33122 UNIN DADE COUNTY OWNER AAJ ADVANCE ELECTRICAL CORP Sec. Type of Business 196 ELECTRICAL CONTRACTOR THIS 1S ONLY A LOCAL BUSINESS TAX RECEIPT. IT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING LAWS OF THE COUNTY OR CmES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS 1S NOT A CERTIFICATION OF THE HOLDER'S QUALIFICA- TIONS. PAYMENT RECEIVED MIAMI -DADE COUNTY TAX COLLECTOR: 08/10/2011 02210009001 000075.00 SEE OTHER SIDE MIAMI -DADE COUNTY TAX COLLECTOR 140 W. FLAGLER ST. 1st FLOOR MIAMI, FL 33130 RECEIPT NO. FIRST -CLASS U.S. POSTAGE PAID MIAMI, FL PERMIT NO. 231 WORKER /S 4 DO NOT FORWARD AAJ ADVANCE ELECTRICAL CORP JESUS ALFONSO PRES 2035 SW 123 CT MIAMI FL 33175 2011 MUNICIPAL CONTRACTOR'S 2012 TAX RECEIPT MIAMI -DADE COUNTY - STATE OF FLORIDA PURSUANT TO COUNTY CODE SEC. 10-24 EXPIRES SEPT. 30, 2012 THIS IS NOT A BILL — DO NOT PAY 30- 3979599 CC NO: 97E000253 BUSINESS NAME / LOCATION AAJ ADVANCE ELECTRICAL CORP 3309 NW 74 AVE OWNER :AAJ ADVANCE ELECTRICAL CORP SEE BACK OF RECEIPT FOR A LIST OF NON - PARTICIPATING MUNICIPALITIES Receipt holder must register in the city where work is to be done. PAYMENT RECEIVED MIAMI -DADE COUNTY TAX COLLbCI710 /2011 02210009002 000200.00 FIRST -CLASS U.S. POSTAGE PAID MIAMI, FL 'PERMIT NO. 231 RECEIPT HOLDER MAY DO BUSINESS AS A CONTRACTOR AS SPECIFIED HEREON. ELECTRICAL CONTRACTOR DO NOT FORWARD AAJ ADVANCE ELECTRICAL CORP JESUS ALFONSO PRES 2035 SW 123 CT MIAMI FL 33175 1 :al 111, 11111, III /1,1, 1111111111 ,1 sir if, Ins 1111 ill 1iaf11trill FL.QI ID Remedy b oar EA8 GIB`' _Under the ,ptiotitifions of Chap Expiration date: AUG- 3,1 201 (I16,3DTvITTA ST,,MM., A1Z, QUI, AIX 26211' MIAMI • CTQB Construction Trades Qualifying Board BUSINESS CERTIFICATE OF COMPETENCY 97E000253 A A J ADVANCE ELECTRICAL CORP D.B.A.: ALFONSO JESUS Is certified under the provisions of Chapter 10 of Miami Dade County Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 •••geveral properties in Miami Shores Village are located in a Special Flood Hazard Area (SFHA) as determined by the Flood insurance Rate Map (FIRM). Development in a SFHA requires special attention to help protect fife and property in the unfortunate event of a flood. Miami Shores Village Flood Damage Prevention Ordinance requires that the Building Department determine if a structure will be "Substantially Improved" prior to issuing any permits for improvement or repair. "Substantial Improvement" is defined in Miami Shores Village Flood Damage Prevention Ordinance as follows: "any reconstruction, rehabilitation, addition, or other improvement of a structure, the cost of which° equals or exceeds 50 percent of the market value of the structure before the "start of construction" of the improvement. This term includes structures that have incurred "substantial damage" regardless of the actual repair work performed." The starting date to determine cumulative costs will be 12 months prior to the issuance of any permit underkonsideration. All future work considered would require appropriate approvals prior to construction. All cumulative costs will be re- evacuated at the time the permits are issued. 0: Why wasi the 50% figure chosen as the substantial improvement threshold? A: The 50% threshold was chosen as a compromise between the extremes of 1) prohibiting all investment to structure in SFHA and 2) allowing structures to be improved in any fashion without regard to the hazard present. In the first alternative there is potential for causing hardship to hose who have located in a SFHA without knowledge of the risk because the structure was constructed prior to the designation of the area as flood prone. These individual could not improve their structures as damage or age contributed to their deterioration. The second alternative provides no mechanism to ensure that increased investment in SFHA will receive needed protection from flood risk. thus contributing to the increased peril of life and property. The threshold is thus a compromise at a halfway point. "Market Value" is defined in Miami Shores Village Flood Damage Prevention Ordinance as follows: " the building value, which is the property value excluding the land value and that of the detached accessory s ructures and other improvements on site (as agreed to between a willing buyer and sealer) as established by what the local real estate market will bear. Market value can be established by an independent certified appraisal (other than a limited or curbside appraisal, orone based on income approach), Actual Cash Value (replacement cost depreciated for age and quality of construction of building), or adjusted tax - assessed values." Note: The "Market Value" does not include the value of the land or other improvements on the property. (ie: pool, gazebo etc.) Created on June 2009 11-15qo A "substantially improved" structure in a Flood Zone must be brought into compliance with Miami Shoreis Village Flood Damage Prevention Ordinance for new construction. This means a residential structure must be elevated to or above the level of the 100 -year or base flood and a commercial Structure must be effectively "flood proofed" and meet other applicable requirements. These regulations are based upon the Federal Emergency Management Agency (FEMA) requirements and affect your flood insurance costs. Existing residential structures can be "substantially improved" by interior renovations or new additions or other improvements. EXAMPLE: In order to determine whether a proposed construction project would be classified as a substantial improvement, the market value of the building needs to be determined. This value is found on the official tax assessor's card for the property or may be obtained by a licensed property appraiser. That number is then divided by 2 to determine the substantial improvement threshold. Therefore, a home with a market value of $100,000.00 could have no more than $50.000 worth of new construction/renovations and/or repairs before the house would have to be elevated above the 10,0 year base flood elevation as shown on the Flood insurance Rate Maps. It is the respgnsibility of the Building Department staff to ensure that the market value estimates are accurateand the cost estimate reflects the actual costs to fully repair the damage and make any other improvements to the structure. The staff requires that the permit applicant or owner of the building Supply the proposed construction cost estimate, or contractor's contract, to make the determination. The staff then uses the latest "Means Square Foot Costs" and "Means Construction!Cost Data" books to determine the accuracy of the estimate. These are nationally accepted manuals, which itemize all components involved with construction. The manual provides adjustment rates to handle the varying construction costs throughout the country. 0: What shb uid be Included in a contractor's estimate? A: Basically,the only items that are not included in the cost include plans, specifications, surveys and "permit fees. All materials that are permanently a part of the structure should be Included in the cost estimate. These items include. but are not limited to: windows, doors, hardwood floors. wall to wall carpeting, sheetrock. lumber, roofing material, footings. pilings, kitchen cabinets and counter tops. bathroom vanities, tiling, plumbing fixtures, new furnaces. hot water heaters, heating and air conditioning systems. electrical work and labor. The cost of all materials involved in new construction or replacing and restoring a structure to its pre - damaged condition mdst be included. Even if volunteer labor or self-labor is used. it must be estimated based on minimum -hour wage scales for the type of construction work that is done. Created on June 2009 CUMULATIVE SUBSTANTIAL IMPROVEMENT VERIFICATION WORK SHEET In accordance With FEMA regulation and Miami Shores Village Flood Damage Prevention Ordinance the ants of all improvements roust be monitored. The costs of anp improvements in the past 12 months and the costs of any proposed improvements Must be shown on the worksheet. The cost of improvements must include demolition. raw and finished materials tinclttde thine donated). labor (including volunteer and self - performed), construction supervision and management. and overhead and profit. A list of items the costs of which are to be included as well as those excluded is attached for pour reference. (A Cop.' of the Contract must be attached) G PROPERTY OWNER: VC r, L0,10 PERMIT# ADDRESS. 6/e)./4; A) ,,)at r.)44;10 b FOLIO NUMBER: 1 f 3)5. C /0590 FLOOD ZONE: RASE FLO011 ELEVATION: 11, • rFREEBOARD: COST OF PAST MOVEMENTS (12 MONTHS): COST OF PROPOSED IMPROVEMENTS: 1" , 5.00 0 V (ATTACH C I'Y OF CONTRACT) TOTAL CUMULATIVE COST OF IMPROVEMENTS (past and proposed): ,]Y/ 6)2.4!:9 d vi EAST OF FL.CCCL: VALUE OF PUNT1PAL STRU RE (attach appraisal): & © OWNERS SI NATURE: DATE: PLANREVIEWER: PLAN REVIEWER SIGNATURE: DATE: Created on June 2009 • AAJ ADVANCE ELECTRICAL CORP 2035 S.W. 123 CT MIAMI, FLA 33175 PH: 305- 221 -3201, CEL: 305- 986 -0435 CC# 97E 000253 ER- 0014520 NAME /ADDRESS YVES LAMBERT 9215 NORTH BAY SHORE DRY MIAMI SHORE FLORIDA CONTRACT DATE 1 ESTIMATE NO. 8/20/2011 2072 DESCRIPTION TOTAL THIS PRICE INCLUDES: 1) PROVIDE AND INSTALL THREE S/DETECTOR 2) PROVIDE AND INSTALL SUB -MAIN AT EXISTING PANEL TO NEW SUB -PANEL "B ". 3) PROVIDE AND INSTALL NEW GROUNDING BAR AT EXISTING PANEL "A" ACCORDING TO CODE 4) PROVIDE AND INSTALL NEW SERVICE 200 AMPS COMBO ( NEW MAIN DISCONNECTING AND FOUR NEW SPACE BREAKER CKTS ) 5) PROVIDE AND INSTALL GROUNDING SYSTEM TO CODE . 6) PROVIDE , INSTALL AND TRENCH FOR TWO PVC CONDUIT 3/4 FROM EXTERIOR NEW SERVICE COMBO TO MARINE AREA. 7) PROVIDE AND INSTALL NEW ITE BREAKER 45 AMPS FOR A/C AT SECOND FLOOR. THIS PRICE DOESN'T INCLUDE: 1) ELECTRICAL PERMIT FEE. 2) ANY VIOLATION OR ANYTHING THE INSPECTOR REQUIRES, FEE ADDITIONAL WE HEREBY PROPOSE LABOR MATERIALS. 4,375.00 Thank you for your business. T OTAL $4,375.00 SUBSTANTIAL IMPROVEMENT / DAMAGE LIST (NOTE: THIS LIST IS INTENDED FOR GUIDANCE ONL Y. AND IS NOT ALL ITEMS TO BE INCLUDED ALL STRUCTUAL ELEMENTS, INCLUDING Foundations including; Spread footing, Continuous footing, isolated footing, piles and pile caps Slabs including; Monolithic, floating, elevated Walls including; Exterior walls, Bearing walls, Shear wails Beams, Tie Beams, Columns and Posts Wood decking, Floor and Roof Sheathing Trusses, Joist Windows /doors ALL BUILDING ELEMENTS, INCLUDING Interior Partitions, Wails, Columns Drywall, Ceilings, Built in Furniture, Cabinets, Vanities All Fixtures Flooring, Tile, Carpet, Stone, Linoleum, ect. All Finishes including Drywall, Paint, Stucco Plaster, Paneling, Tile, Marble, and Moldings Roofing Material ALL HARDWWARE ALL UTILITY and SERVICE EQUIPMENT HVAC Electrical System and Equipment Plumbing System and Equipment Security System and Equipment Central Vacuum System Plumbing Fixtures Lighting Fixtures and Ceiling Fans Water Systems including Softeners /Filtration Created on June 2009 ALSO: NCLUSIF E) All Labor and other Costs associated with Demolition, Removing, Replacing, Installing Building or Altering Building Components Construction Management / Supervision Overhead and Profit Equivalent cost for: Donated Materials Volunteer Labor (including owners and friends) Any Improvements Beyond Pre- damaged Condition, including; Utility Upgrades Code Upgrades ITEMS TO BE EXCLUDED Plans and Specifications Survey Costs Elevation Certificate Costs Permit fees Debris Removal Items not considered to be REAL Property Rugs, Furniture, Refrigerator, Appliances not Built -in Outside Improvements, Including; Landscaping Sidewalks Patios Fences Yard lights Sheds Gazebos Irrigation Pool