RF-11-1990Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 167884 Permit Number: RF -10-11 -1990
Scheduled Inspection Date: December 16, 2011
Inspector: Bruhn, Norman
Owner: WINCKLER, MARINA
Job Address: 1020 NE 98 Street
Miami Shores, FL 33138-
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Repair Roof
Phone Number
Parcel Number 1132050180310
Phone: (305)953 -3333
Building Department Comments
REPAIR LEAK AT FRONT EAST SIDE ROOF
//W-ic
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
CREATED AS REINSPECTION FOR INSP - 165912. cancelled by mary lu
'C_,,
December 15, 2011
For Inspections please call: (305)762 -4949
Page 12 of 16
B LDING
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
Permit No. --4C0 0
PERMIT APPLICATION
FBC 20
Permit Type: BUILDING ROOFING
Owner's Name (Fee Simple Titleholder) Marina M . Winckler Phone # (3 0 5) 7 51— 6 0 0 5
Owner's Address 1020 N.E. 98 Street
City Miami Shores State F1
RECEIVED
OCT 282011
Master Permit No.
Tenant/Lessee Name
Email
Zip 33138
Phone #
Job Address (where the work is being done) 1020 N. E. 98 Street
City Miami Shores Village County Miami -Dade Zip 33138
FOLIO / PARCEL # 1 1- 3205 -018 -031 0
Is Building Historically Designated YES NO X Flood Zone
Contractor's Company NamQuaity Roofing Contractor, Incphone# ( 305) 953 -3333
Contractor's Address 13800 N. W.• 1 st Avenue
City Miami State Fl Zip 33168
Qualifier Name Carlos Arocho
State Certificate or Registration No. RC 0 0 5 8 6 2 7 Certificate of Competency No. 00 0 017889
Contact Phone (305) 953 -3333 E -mail qualityroofing88 @yahoo.com
Phone # ( 786) 367 -2029
Architect/Engineer's Name (if applicable) Phone #
Value of Work For this Permit $ 2, 300.00 Square / Linear Footage Of Work: 1 0 0 sqf t .
Type of Work: ❑Addition ['Alteration ['New g Repair/Replace ❑ Demolition
Describe Work: Reapir leak at front east side of roof .
Submittal Fee $ Fee $ /00 e. CCF $ CO /CC $
Notary $ Training/Education Fee $ Technology Fee $
Scanning $ Radon $ DPBR $ Bond $
Double Fee $ Violation date:
Structural Review. $ Total Fee Now Due $ (1i24"6
See Reverse side -+
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will n be approved and a reinspection fee will be charged.
Signature
sa.� ice`
Signature
Owner or Agent Contractor
The foregoing instrument was acknowledged before me this 1/ The foregoing ' trument was acknowledged before me this
day of ail , 2011 , by , o k i c A � i � c i l e . � i i G / , day of , 2 11 , by 1.4o., p c9
who is person nopn to me or who has produced who is personally,.known to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
VC `'00 NO& 31.2 0 ..Lb mIH.L CHCtdOE
My Commission Expir =:.TOZ `0T 130 :saatdxS " "•o
91700£6aa# uoTssimuloOf.
zapueuaaH tt0?S.IR'W
VC1nou3,30 IV1S•DI1HI1d X iVIOAt co,rrta
* ***** * *: *> ti�r�r***** * * * * **** * * *** * * *** * * *** *** ** * ** fir ' * *** * * **
NOTARY PUBLIC:
Sign:
Print:
y eer
NOTARY PUBLIC- A
y t rie " 1� �� Expiiq r y PUBLIC -sm OF ^�A
• Commission #DD930046 .'����;'•• Maryi, z
a
Expires: OCT. 10, 2013 w_ Cam'
APPROVED BY
/o —If-I( Plans Examiner
Engineer
(Revised 07 /10 /07)(Revised 06/10/2009)
Expir..7. 013
Zoning
Clerk checked
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govem the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. Theowner's initial in the designated space indicates the ttmbas= eert- ezp—Carned:
1.
Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the agreement between the owner and the contractor.
2. 1 ®1{W Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof-deck is usually concealed prior
to removing the existing roof system).
Common roofs: Common roofs are those which have no visible delineation between neighboring
s (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or
owner should notify the occupants of adjacent units of roofing to be performed.
Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
e viewed from below. The-owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appearance.
5. Ponding water: The current roof system and /or deck of the building may not drain well and may
use water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and. performance of the new roofing system. Pounding conditions may not be evident until the
original roofing System is removed. Pounding conditions should be corrected.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if .
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. / yl 1 Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of the
roof.
/D -/9- 7/ _
Owner /Agent's Signature Date Contractor Signature
Revised on 7/9/2009 LD
Date
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Bulldmg ode Edition pp
I�rT TO COMPI-IANCE WITH ALL FEDERAL
High- Velocity Hurricane Zone Uniform Permit Application Form.
n RI II FS AND REGULATIONS
Section A (General Information
Master Permit No. Process No.
Contractor's Name Ouality Roofing Contractor, Inc.
Job Address 1020 N. E. 98 Street
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile
❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes
Shingles
❑ Prescriptive BUR -RAS 150
ROOF TYPE
❑ New Roof ❑ Reroofing ❑ Recovering
Low Slope Roof Area (SF)
ROOF SYSTEM
INFORMATION
XX Repair ❑ Maintenance
Steep Sloped Roof Area (SF) 100sgft. Total (SF) 100sgft.
SAntinn R (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets.
FLORIDA BUILDING CODE — BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High - Velocity Hurricane Zone Uniform Permit Application Form.
Spctinn tl (Steep Sloped Rnof System) *Existing Roof*
Roof System Manufacturer: Clay Forever, LLC
Notice of Acceptance Number:
07- 0919.05
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations):
P1: N/A P2: N/A P3: N/A
Maximum Design Pressure
(From the Product Approval Specific System):
Roof Slope:
3 : 12
Steep Slnped Rnnf System nesrriptinn
Deck Type: Wood 1 X 6
Type Underlayment: 301b.
Insulation: N/A
Fire Barrier: N/A
Ridge Ventilation? Fastener Type & Spacing: N/A
N/A
Mean Roof Height: 131
Adhesive Type:
Type 111 mopping asphalt
Type Cap Sheet: 901.b
Roof Covering: Spanish S Clay Tile
Type & Size Drip 3 X 3 26 ga. galv.
• Edge:
FLORIDA BUILDING CODE — BUILDING
M I A M I•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI-DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375 -2908
Clay Forever, LLC
6801 NW 77th Avenue
Miami, FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Altusa "S" Clay Roof The
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA #06- 0706.09 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 07- 091905
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category:
Sub- Category:
Material:
Roofing
Roofing Tiles
Clay
1. SCOPE
This renews roofing system using Altusa One Piece S' Clay Roof Tiles, as manufactured by
Alfareria Del Turbio, S.A. (ALTUSA) in Venezuela and described in Section 2 of this Notice of
Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be done as a
moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant Dimensions
Altusa One Piece `S' L =18 Vs"
Tile W = 10.5"
Vs" thick nominal
3.25" high
Trim Pieces Length: varies
Width: varies
varying thickness
L = 6"
D= 0.125"
L &h = 2"
W =Y2"
0.05" thick
Clip
Clip
2.1 SUBMITTED EVIDENCE:
Test Agencv
IBA Consultants, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation Testing
Test
Specifications
TAS 112
TAS 112
TAS 114
TAS 114
Test Identifier
2397 -116
94-083
94-084
25- 7200 -1
Project No. 307025
Test #MDC -78
MTS 520649
Product
Description
High profile clay roof tile. For direct deck or
batten nail-on, mortar set or adhesive set
applications withminimal headlap of 2-%z"
Accessory trim, clay roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Tile clip
L Shaped tile clip
Test Name/Report
ASTM C 1167 06/28/07
Static Uplift Testing April 1994
TAS 101 (Adhesive Set)
Static Uplift Testing May 1994
TAS 101 (Mortar Set)
Static Uplift Testing Feb. 1995
TAS 102
(Quick-Drive Screws,
Battens)
Wind Driven Rain ' Oct. 1994
TAS 100
TAS 102(A) May 2000
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page2of7
Test Agency
PRI Asphalt Technology, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Test Identifier
CLF-003 -02 -01
7161 -03; Appendix III
7161 -03
Appendix II
Letter Dated Aug. 1,
1994
P0631 -01
P0402
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with RAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified 'Laboratory to perform
quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 'Altura One Piece S' Clay Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Test Name/Report
TAS 102
TAS 102
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Aerodynamic Multiplier
25 -7183
25 -7094
25 -7496
25 -7584
25-7804b-8
25-7804-4 & 5
25- 7848 -6
Date
October 2001
Dec. 1991
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
March 1999
March 1995
February 1996
April 1996
December 1996
NOA No.: 07. 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 3 of 7
Table 1: Average Weight (W) and Dimensions (1 x w )
Tile Profile
Altusa 'S' Tile
1 Weight- W.(1bn Length -I (ft) Width -w (ft)
6.9
1.52
0.875
Altusa 'S' Tile
Tile
Profile
Table 2: Aerodynamic Multipliers - (ft3)
a (ft)
Batten Application
0.253
). (ft3)
Direct Deck Application
0.274
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table
Table 3: Restoring Moments due to Gravity - Mh, (ft-lbf
Tile
Profile
'S'
3 ": 12"
or less
4 ": 12"
5 ": 12"
6 ":12"
7 ": 12" or
greater
Altusa Tile
Battens I
Direct
Deck
Battens
I Direct
Deck
Battens
Direct
Deck
I
Battens
Direct
Deck
I
Battens
Direct
l Deck
4.47
5.35
4.40
5.27
4.31
5.16
4.20
5.03
4.08
I 4.89
23.1
23.1
19.0
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table
4: Attachment Resistance Expressed as a Moment - Mf (ft Ibf)
for Nail -On Systems
Tile
Profile
'S'
Fastener Type
Direct Deck
(Min 15/32"
plywood)
Direct Deck
(Min. 19/32"
plywood)
Battens
Altusa Tile
2 -10d Ring Shank Nails
28.6
41.2
19.4
1-10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2 -10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 . #8 Screw
28.7
28.7
N/A
2 . #8 Screws
58.2
58.2
26.8
1 -10d Smooth or Screw
Shank Nail (Field Clip)
23.1
23.1
19.0
1 -10d Smooth or Screw
Shank Nall (Eave Clip)
29:3
29.3
24.0
2 -10d Smooth or Screw
Shank Nails (Field Clip)
27.6
27.6
38.6
2 -10d Smooth or Screw
Shank Nails (Eave Clip)
38.1
38.1
41.8
1 Screw with Altusa Clip (See c
Ip details)
Altusa "S"
Tile'
1 Screw with clip (at the
head of tile)
187.1
187.1
N/A
Altusa "S"
Tile'
1 Screw with clip (at the
water course of tile)
35.2
352
N/A
1. Screw must be installed in the Inside nail hole located nearest to the hump of the.tile.
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table 6: Attachment Resistance Expressed as a Moment Mr (ft lbf)
for Two Patty Adhesive Set Systems
Tile
Tile Application
Profile
Altusa `S' Tile
Adhesive
2 See manufactures component approval for installation requi
PROFILE DRAWINGS
ALTUSA `S' CLAY ROOF TILE
°SPANISH S°
TILE BY AL
(TYP.)
CLIP DETAILS
2 -1!2° OVERLAP
(COVERS PIN HOLE)
SCREW IN THE INSIDE HOLE
NEAREST TO THE HUMP OF THE TILE
DECK'
CLIP WITH ONE (1) SCREW
ATTACHED TO DECK
CUP
NOA No.: 07- 0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 6 of 7
SCREW (HOLDS
CUP ONTO DECK)
'SPANISH S°
TILE BY ALTUSA
(rYP.)
CLIP DETAILS (CON'T)
21/2° OVERLAP
(COVERS PIN
HOLE)
SCREW IN THE INSIDE NAIL HOLE
NEAREST TO THE HUMP OF THE TILE
CLIP PLACEMENT DETAIL
DECK
11 /4° 13/4' 3/4°
• i s
END OF THIS ACCEPTANCE
NOA No.: 07-0919.05
Expiration Date: 12/16/12
Approval Date: 12/20/07