RF-11-1850Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 165310 Permit Number: RF -10 -11 -1850
Scheduled Inspection Date: December 13, 2011
Inspector: Bruhn, Norman
Owner: TORRES, HERBERT
Job Address: 190 NW 105 Street
Miami Shores, FL 33150 -1244
Project: <NONE>
Contractor: JOHN BUSTA ROOFING INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number
Parcel Number 1121360131350
Phone: (305)757 -7620
Building Department Comments
RE -ROOF TILE OFF REPLACED WITH NEW
COLOR -THRU CONCRETE TILE
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
December 12, 2011
For Inspections please call: (305)762 -4949
Page 15 of 33
CIVIL
RIV
ENGINEER
Reileh Engineering Corp.
(Consulting Engineer)
2370 S.W. 123 Avenue
Miami, Florida 33175 -1174
Tel : 305- 823 - 8008 / 305 -397 -6414
Fax: 305- 823 -3300 / 305 - 884 -8834
Website: www.reilehenOneering.com
December 2, 2011
John Busta Roofing
300 Northeast 91 Street
Miami Shores, Florida 33138 -3130
Project:
Dear Sirs;
ROOF TILE UPLIFT TEST REPORT
Residential Home
190 Northwest 105 Street
Miami Shores, Florida
Information provided by client:
Permit Number: 10111850
Date Completion: November 24, 2011
Roofing Contractor: John Busta Roofmg
Project Number: 11 -0960
(Testing Laboratory Certificate #06- 0501.15)
In accordance with your request and authorization, a representative of Reileh Engineering Corporation
completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general
accordance with Roofing Application Standard TAS No.106 -- Standard procedure for field verification
ofthe bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof
systems.
The total ofthe tested roof surface area was less than 10000 square feet, and the mean height of the roof
is less than 40 feet above ground surface. The type of tile used for this project was reported to be
Vanguard Roll Roof Tile. This tile was reported to have been foamed in place.
At the time of our inspection, the entire area ofthe roof was examined for loose tiles. Not less than one
(1) tile in ten (10) of all components in the field area and one (1) tile in five (5) of all tiles in the perimeter
and comer areas were physically examined. A minimum of one (1) test per every two (2) squares in the
field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer areas were conducted.
Based on our test results . we conclude that the installation ofthe roofti ee at
meets the test requirement outlined in the above - mentioned protocol. At-tac
test report for your review.
enced project
a copy of our
Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have
any questions or if we may be of further assistance, please do not hesitate to contact the undersigned.
Respectfully submitted;
Reileh Engineering Corporation
ohamad Sonny Salleh, P.E.49014
roject Manager
TILE UPLIFT TEST
Residential Home
190 Northwest 105 Street
Miami Shores, Florida
Reileh Engineering Corporation -- Project Number - 11 -0960 — Page 2 of 4
Report of
TILE UPLIFT TEST
for
Residential Home
190 Northwest 105 Street
Miami Shores, Florida
Project Number: 11 -0960
Test Number
1
35
Pass
2
35
Pass
3
35
Pass
4
35
Pass
5
35
Pass
6
35
Pass
7
35
Pass
8
35
Pass
9
35
Pass
10
35
Pass
11
35
Pass
12
35
Pass
13
35
Pass
14
35
Pass
15
35
Pass
16
35
Pass
17
35
Pass
18
35
Pass
19
35
Pass
20
35
Pass
21
35
Pass
22
35
Pass
23
35
Pass
Reileh Engineering Corporation — Project Number - 11 -0960 — Page 3 of 4
Test Number
Test Load (lbf)
24
35
Pass
25
35
Pass
26
35
Pass
27
35
Pass
28
35
Pass
29
35
Pass
30
35
Pass
31
35
Pass
32
35
Pass
33
35
Pass
34
35
Pass
35
35
Pass
Test 1 -8 Comer, 9 -13 Ridge Caps, 14 -19 Perimeter, 20 -35 Field
Reileh Engineering Corporation -- Project Number - 11 -0960 — Page 4 of 4
30'
1
8
15
14
6
5
16
29
30
0
0
24
31
29
27
26
2
20
0
0
35
54
19
23
3
32
22
33
12
17
18
3 k
60'
Th51' 11LE
FEW = 16
PEf;IMETEP 6
CCM = 8
PIM CAP = 5
pip METl;l2 - 600 5F
COMER - 40 5F
NO, TE51' LOCA11ON
MRIMMR 1715TANa, a = 3'
C012 R AMA = 31X 3'
0 Ian CAP TE51" LOCATION
t317ENOTE5 [3ROKEN 11LE
L MOTES 1.00% 11LE
11 -0960
MFROX, ROOF TEST LOCATIONS AN17 171MEN5ION5
RE: Permit #
1 \f2/V// B(/s74
Miami Shores Village
Building Department
INSPECTION AFFIDAVIT
(Print name and circle License Type)
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
DATE:
licensed as a (n) Contractor / Engineer / Architect,
FS 468 Building Inspector
License #: �� — 0_5 e 5Z
On or about / ` ` % ` ..,0 // e, / Af , I did personally inspect the roof deck nailing and
(Date & time)
Secondary water barrier work at /70 /i1 £ (' /0,- c17---",
(Complete Job Site Address)
Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit
Manual (Based on 553.844 F.S)
Signature
State of Florida
County of Dade:
The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property
mentioned.
Sworn to and subscribed before me this
Notary Public, Sate of Florida at Large
SC day of OC'
�%%P'Y P
6 . ,, , LORRAINE KELLER
� 1►?
r'c • Notary Public - State of Honda
• •= My Comm. Expirpc f F, 20 • 4
Via` Comm +s
,iFOF110'
d:.
'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an Inspection. Include photographs of each plane of the roof with
permit# and address # clearly shown marked on the deck for each Inspection
Revised on 512112009
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
BUILDING Permit No. - -
'
PERMIT APPLICATION
FBC 2004
Master Permit No.
Permit Type (circle):. Building Electrical Plumbing Mechanical Roofing
146
Owner's Name (Fee Simple Titleholder) b,„--1 "i l i 17,, ,` " Phone #
Owner's Address a (1C, N \,,1 8 - SI
City "�d��e�tii� "� i���a� State
Zip
9
Tenant/Lessee Name Phone #
Job Address (where the work is being done)
City Miami Shores Village County Miami -Dade
FOLIO / PARCEL # I _ ° ) t V L"
Is Building Historically Designated YES NO 6"°-
Zip ,�` �` �✓i�_��
Contractor's Company Name a� �„
��� �d� q � I , �� ill., d �F� Phone # G ° '26), C
Contractor's Address L`C'i 'K;7.-Z. (- '/ Z.'1. i
City d'' (i „' 1: ' „1 ,_� � �,_�� State H L Zip
Qualifier Name k,al )3 c,,C=;,-- 4'u;'k Phone #
State Certificate or Registration No. (C' c (:)S7 L -/ Certificate of Competency No.
Architect/Engineer's Name (if applicable)
Value of Work For this Permit $
()Co
Phone #
,
Square / Linear Footage Of Work:
T e of Woriz DAddition [Alteration New t. 1s$apair/Replace 0 Demolition
D :gibe Work y
******** * * * ** * * * * * * * * * * * * * * * ** * * * * * * * ** Fees************* * * * * * * * * * * * * * **** * * * * * * * * * * * * **
Submittal Fee $ r, Permit Fee $ CCF $
Notary $
Scanning $
Training/Education Fee $
Radon $
CO /CC
Technology Fee $
DPBR $ Zoning $
Bond $ Code Enforcement $ Double Fee $
Total Fee Now Due $
See Reverse side -*
Structural Review. $
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that_no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approvgd and a reinspection fee will be charged
The foregoing instrument was acknowledged before me this
day of � , by `'a/:, ' ,
w%as sonally known me me or who has produced
As identification and who did take an oath. =-
NOTARY PUBLIC:
My Commission Expires:
Notary Public - State of Rant
3• ,• y • _My CommfsfiOn Expirca Apr 16.
Comnision # DD 52048F
Bonded by National Notary
* * * ** * * *** * ***** *** * * ***
APPLICATION APPROVED BY:
(Revised 02/08/06)
Signatureee j
Contractor
The foregoing instrument was acknowledged before me this _ 3
day of C-It`- . , 20 I , byf�_��
who is personally knowli to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
My Commission
Plans Examiner
Engineer
Zoning
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO. 11 ' 313L2 t 13 -1550
STATE OF FLORIDA:
COUNTY OF MIAMI -DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real
property, and in accordance with Chapter 713, Florida Statutes, the following information
is provided in this Notice of Commencement.
1 111111 11111 11111 11111 11111 11111 11111 1111 1111
(-FN 2011.. R0682633
DR Bk 27855 Psi 2349; (1 p a )
RECORDED 10/12/2011 10 :34:5:
HARVEY RUVIN CLERK OF COURT
MIAMI—DADE COUNTY? FLORIDA
LAST F'AGE
C Space above reserved for use of recording office
1. Legal description of property and street/address: ivli,A X11 Sl-iit's . ;c - 5 i 1, l - 4 1,61 1 171K 1 1'
VIL) lam mil. o,,, ;;i��r �, F� 53(.5e, /2'
2. Description of improvement: ( P -
3. Owner(s) name and address: \-i -ei bc' +' -1 /c; ' ' € 5
Interest in property: C:7'. -..1
Name and address of fee simple titleholder: 1 `i C C', 1'-) - - C• ?- )J, 1 ,,5{;,;; e'5 r L 3,j1 imggq
4. Contractor's name, address and phone number: - t.. L",,, '1___' , ) c:; I.2 o _ r ; c -1 , i t
S
5. Surety: (Payment bond required by owner from contractor, if any)
Name, address and phone number: „ i I
Amount of bond $ i 1 ■ / rl.
6. Lender's name and address: ` v / = STATE OF FLORIDA. coutcrf f3F o
7. Persons within the State of Florida designated by Owner upon MI not<i e
Section 713.13(1)(a)7., Florida Statutes, . °Tti=i°'0'''` ., in `I`
Name, address and phone number:) I ' ," -TIP rdF
8. In addition to himself, Owners designates the following person
713.13(1)(b), Florida Statutes. !3y
Name, address and phone number:
li'1� J
9. Expiration date of this Notice of Commencement:
(the expiration date is 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE' NOTICE OF COMMENC.EMENTARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORDING YOUR NOTICE OF COMMENCEMENT. p
Signature(s) of Owner(s) or Owner(s)' Authorized Officer /Director /Partner/Manager
Prepared By
Print Name 1-1‘2:n 11; QS
Title /Officev'��
STATE OF FLORIDA
COUNTY OF MIAMI -DADE
The foregoin instru ent was acknowledged before me this
By 2Qt k t Ulf 4%eS
U Infiividuaily, or as
ersonally known, or ❑ produced the following type of identification:
Signature of Notary Public:
Print Name:
(SEAL)
VERIFICATION PURSUANT TO SECTION 92.525, FLORIDA STATUTES
Under penalties of perjury, I declare that I have read the foregoing and
that the fac stated in it are true, to the best of my knowledge and belief.
Prepared By
Print Name
Title /Office
day of }a- t��( (
for v,
A- 11 S FOP I I P✓
"'��•.,, LORRAINE KELLER
=g�� .�'�: , Notary Public - State of Florida
•? My Comm. Expires Apr 16, 2014
��` . Commission # DD 966253
o •wner(s)'s Authorized Officer/Director / Partner/Manager w
1 '•°iP.��`' ' prided Through National Notary „F. •
Signature
By
123.01 -52 PAGE
By
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, Fl 33138
Re: Owner's Name:
Property Address: 9 7 `' /(4'/
Date: /0- (7 5
Roofing Permit Number:
Dear Building Official:
1 certify that I am not required to retrofit the roof to wall connections of my
building because:
The just valuation for the structure for purpose of ad valorem taxation is Tess than $300,000.00. Please attach proof of ad
valorem taxation.
❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of t e South Florida Building Code (1994 SFBC)
Sign .ture Print Name
ew be v Ic Tali 6'
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this - day of
Notary Public, Sate of Florida at Large
n�,
euwp4
�.�PRY �'4��i LORRAINE KELLER
r° e`'S Notary Public - State of Florida
Q; ° My Comm. Expires Apr 16, 2014
Commission # DD 966253
Rr ,ded Th Miner @
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the buil
SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revue on 512112009
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High - Velocity Hurricane Zone Uniform Pennft Application Form.
_i''
OCT 0 7 2011 gll
Spr_tinnA (Gpn Inrm
aral fnatinn)
Master Permit No. 12c iC<S 1 1 t.J Process No.
Contractor's Name - L L ) .11))6')-) ('d
Job Address t 40
❑ Low Slope
❑ Asphaltic
Shingles
❑ Mechanically Fastened Tile
❑ Metal Panel /Shingles
❑ Prescriptive BUR -RAS 150
ROOF TYPE
❑ New Roof 12/Reroofing ❑ Recovering
ROOF SYSTEM
INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF)
II
Section R (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets.
D Mortar /Adhesive Set Tile
❑ Wood Shingles /Shakes
❑ Repair ❑ Maintenance
Total (SF)
Mia
Ito ph'. res
B
agf
DATE
7 G JEF1T
FLORIDA BUILDING CODE — BUILDING
BLDG DEPT
SURJFCT TO COMPLIANCE WITH ALL FEDERAL
STATE AND COUNTY RULES AND REGULATIONS
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High - Velocity Hurricane Zone Uniform Permit Application Form.
Spctinn D (Stepp Sloped Roof System)
Roof System Matl�ufacturer:, r
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations):
P1: I /- -' P2: ' ', P3: / e(/
Maximum Design Pressure
(From the Product Approval Specific System):
Roof Slope:
: 12
Steen _Sloped Roof System ❑e
\ Deck Type:
Type Underlayment:
Insulation:
Ridge Ventatlon?
9A
Fire Barrier:
Mean Roof Height:
Fastener Type & Spacing:
Adhesive Type:
Type Cap Sheet:
Roof Covering:
" }' 5 [J'
ca. C"
d Ad1i�r�RJ
rl � ^ B
tt 9r�
i Cstit' VGi. JIi11��ii i ��
II (dor T!'%'
Type & Size Drip
Edge:
\;'u11if e ( I
FLORIDA BUILDING CODE — BUILDING
r
s
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2007
High - Velocity Hurricane Zone Uniform Permit Application Form.
SeCtinn F (Tile Calrldations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Me If the Mr values are greater than or
equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
Method Y "M "ent Based Tile Calculations Per RAS 127"
(P1 21���' xA. ij/ i Mg: '=Mri f Product ApprovalMf t .L8
L1
(Py: urn ,x. 4 = - y- Mg: - = Product Approval Mf 145 5
(P3: G`! �. i i x A, a �'L d = -� J , I, 6 - Mg: = Mt3 Product Approval Mr- J
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval M
Mr re9uired Moment Resistance*
Mean Roof Height -)
Roof Slope I,
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
35.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28 0
29.4
30.5
32.4
7:12
24.4
26.9
27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals.
For Uplift based tile systems use Method 3. Compared the values for F with the values for Fr. If the F' values are greater than or equal to the Fr values,
for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Moment Based Tile Calculations Per RAS 127"
(PI: x L = x w: = _� - W: x cos B = Frl Product Approval F
(P2: x L = x w: = ) - W: x cos 8 = Fr2 Product Approval F'
(Pa: x L = x w: = ) - W:
x cos 0 = Fr3 Product Approval F
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
x
Product Approval
Restoring Moment due to
Gravity
M g
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
MB
Calculated
Minimum Attachment
Resistance
F
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length
W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
FLORIDA BUILDING CODE - BUILDING
NIAMICALE
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
� ::'e:.i�a ia4 iLf ua�..z idC.1'.Ii�i i4 �.0 di dG ➢G
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: o olystick- Usider-1ayrnents
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA # 09- 0806.07 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category:
Sub - Category:
Material:
Roofing
Underlayment
SBS , APP Self- Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick MTS
underlayment
Manufacturing Location
#2
Polystick IR -Xe
underlayment
Manufacturing Location
#1 & #2
Polystick TU
underlayment
Manufacturing Location
#1 & #2
l- TX-P -s
underlayment
(Facer of Membrane
with surface printing)
Manufacturing Location
#1 & #2
Polystick TU P
underlayment
Manufacturing Location
#2
Polystick Tile Pro
Manufacturing Location
#2
MIAMI•DADE COUNTY
APPROVED
Dimensions
Roll:
65'8" x 3'32/8"
60 mils thick
Roll:
65' x 3'33/8"
Or 65' x 3'
80 mils thick
Roll:
32'10" x 3'33/8"
100 mils thick
Roll:
65' x 3'3 -3/8"
80 mils thick
Roll:
32'10" x 3'33/8"
130 mils thick
Roll:
61' x 3'33/8"
60 mils thick
Test Product
Specification Description
TAS 103 A homogeneous, rubberized asphalt
waterproofing membrane, glass fiber reinforced
with polyolefinic film on the upper surface for
use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
A fine granular /sand top surface self - adhering,
APP polymer modified, fiberglass reinforced,
bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
A heavy granuled surface self adhering, APP
polymer modified, fiberglass or polyester
reinforced, bituminous sheet material for use as
an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
A non - wicking fabric surfaced, self - adhering,
APP polymer modified, fiberglass reinforced
with a high strength polyester fabric, bituminous
sheet material for use an an underlayment in
sloped roof assemblies. Designed as a metal
roofing and roof tile underlayment.
A rubberized asphalt waterproofing membrane,
glass -fiber /polyester reinforced, with a granular
surface designed for use as a tile roof
underlayment.
A rubberized asphalt self - adhering, glass -
fiber /polyester reinforced waterproofing
membrane. Designed as a metal roofing and roof
tile underlayment.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 2 of 8
PRODUCTS DESCRIPTION:
Product
Polystick Dual Pro
Manufacturing Location
#2
Dimensions
Roll:
61' x 3'3-3/8"
60 mils thick
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency
Exterior Research & Design, LLC
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
MIAMI•DADE COUNTY
APPROVED
Test
Specification
ASTM D 1970
Test Identifier
11756.04.01 -1
11756.08.01 -1
02202.08.05
P5110.08.07
P10870.09.08 -R1
P10870.04.09
P33360.06.10
P33370.03.11
P36900.09.11
PRI01111
PUSA- 005 -02 -01
PUSA- 018 -02 -01
PUSA- 035 -02 -01
PUSA - 033 -02 -01
PUSA - 055 -02 -02
PUSA- 083 -02 -01
PUSA- 089 -02 -01
JX20H7A
RX14E8A
DX23D8B
DX23D8A
Product
Description
A rubberized asphalt self - adhering, glass -
fiber /polyester reinforced waterproofing
membrane, specific for use as a high
temperature underlayment. Designed as a metal
roofing.
Test Name/Report
TAS 103
ASTM D 1970
TAS 103
TAS 103
TAS 103
TAS 103 /ASTM D4798 & G155
ASTM D1970
TAS 103
TAS 103 /ASTM D4798 & G155
ASTM D 4977
ASTM D 4977
ASTM D 2523
TAS 103
ASTM D 1970
TAS 103
TAS 103
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
TAS 103 /ASTM D4798 & G155
Date
04/27/01
08/14/01
08/29/05
08/29/07
12/04/08
04/13/09
07/01/10
03/02/11
09/01/11
04/08/02
01/31/02
07/14/03
09/29/06
01/12/06
12/10/07
06/30/08
07/06/09
04/01/08
11/09/09
02/18/10
02/18/10
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: ``Wo�d nan- insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self - adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-1/2" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
MIAMI DADE COUNTY
APPROVED
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 4 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non-
structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used
in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous
assemblies listed except roof tile systems.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations (days)
Polystick MTS
MTS
IR -Xe
TU
TU Plus
TU P
Tile Pro
Dual Pro
Winter Haven, FL.
180
180
180
180
180
180
180
Hazelton, PA.
N/A
30
30
180
N/A
N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9B -72 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and
mechanically fastened roof tile applications. Polystick IR -Xe, and Tile Pro are limited to mechanically
fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile
applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Polystick Ht Xe
Polystick TU, ,
loos TU P, Tile Pro
Flat Tile
Prohibited without battens
5:12
No limitation
, ProftlecTT
Prohibited without battens
Prohibited
c 'twi n
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR -Xe, TU, 11J Plus, TU P, Dual Pro and Tile Pro
may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU
Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If
Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift
resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
MIAMI -DADE COUNTY
APPROVED
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
MIAMI• ' • E COUNTY
APPROVED
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back - nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 61/4 " /12 ", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric
Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of
repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over
the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The
repair should be installed in such a way so that water will run parallel to or over the top of all laps of the
patch.
10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894 -4563.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894 -4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
APPROVED
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 8 of 8
MIAMaD�ADE
COUNTY
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyfoam Products, Inc.
11715 Boudreaux Road
Tomball, TX 77375
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.miamidade.govibuildintr/
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:: oI pr A11160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 06- 0201.02 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No. :11- 0124.04
Expiration Date: 05/10/12
Approval- Date: 04/14/11
Page 1 of 7
ROOFING COMPONENT APPROVAL:
Category:
Sub Category:
Materials:
Roofing
Roof tile adhesive
Polyurethane
SCOPE:
This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2
of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by
applicable building code, does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high
profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a
moment based system for single patty placement, and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test
Specifications
Polypro AH160 N/A TAS 101
Foampro ®RTF1000 N/A
ProPack® 30 & 100 N/A
Product Description
Two component polyurethane foam
adhesive
Dispensing Equipment
Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which
list moment resistance values with the use of Polypro AH160 roof tile adhesive.
PHYSICAL PROPERTIES:
Property
Density
Compressive Strength
Tensile Strength
Water Absorption
Moisture Vapor Transmission
Dimensional Stability
CIosed Cell Content
Test
ASTM D 1622
ASTM D 1621
ASTM D 1623
ASTM D 2127
ASTM E 96
ASTM D 2126
ASTM D 2856
Results
1.6 lbsift.3
18 PS1 Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ft2
3.1 Perm / Inch
+0.07% Volume Change ® -40° F., 2 weeks
+6.0% Volume Change @158`F.,100%
Humidity, 2 weeks
86%
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 11- 0124.04
Expiration Date: 05/10/12
Approval Date: 04/14/11
Page 2of7
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Renort Date
Center for Applied Engineering #94 -060 TAS 101 04/08/94
257818 -1PA TAS 101 12/16/96
25- 7438 -3 SSTD 11 -93 10/25/95
25- 7438 -4
25- 7438 -7 SSTD 11 -93 11/02/95
25 -7492 SSTD 11 -93 12/12/95
Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93
Southwest Research Institute 01- 6743 -011 ASTM E I08 11/16/94
01- 6739- 062b[1] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96
Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98
528454 -9 -1
528454 -10 -1
520109 -1 TAS 101 12/28/98
520109 -2
520109 -3
520109 -6
520109 -7
520191 -1 TAS 101 03/02/99
520109 -2 -1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire
rating.
2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with
their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with
their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F'— MS
w
2
NOA No.: 11-0124.04
Expiration Date: 05/10/12
Approval Date: 04/14/11
Page 3 of 7
INSTALLATION:
1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift
resistance values with the use of Polypro® AH160.
2. Polypro® AH160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with
the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift
based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade
County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof
tile assembly NOA
3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating
Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam
Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority
having jurisdiction.
5. Calibration of the Foampro dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-
1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as
determined at calibration. No other settings shall be approved.
6. Polypro AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing
equipment only.
7. Polypro? AH160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after
Polypro® AH160 has been dispensed.
9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement
Details' herein. Each generic tile profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement
Detail
Single Paddy
Weight Min.
(grams)
Two Paddy Weight
per paddy Min.
(grams)
Flat, Low, High Profiles
#1
35
N/A
High Profile (2 Piece
Barrel)
#1
17 /side on cap and
34 /pan
N/A
Flat, Low, High Profiles
#2
24 -)
N/A
Flat, Low, High Profiles
#3
8
LABELING:
All Polypro!) AH160 containers shall comply with the Standard Conditions listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the
installation of this system.
NOA No.: 11- 0124.04
Expiration Date: 05/10/12
Approval Date: 04/14/11
Page 4 of 7
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
Ewe souse only:
Keep adhesive apprea.
4 In. up from weephales
1) Place enough edheeWetechteveITto23 steep it happlir
square 6�hes tncntao{wigr Ms pen O e stomp applied=
To1rnFro covets nto upsidedown. adhesive
Then lnatell the fife.
Ne ®through plaellecement
to
atihoease
Wane covet We.
Abut bseccndcourse et
pen Ike. Ensure owe end of
pan end over Teem
guahet ewe Ana
Eevectoswe Weephote Pas
(mortar shown)
NOA No.: 11-0124.04
Expiration Date: 05/10/12
Approval Date: 04 /14/11
Page 5 of 7
ADHESIVE PLACEMENT DETAIL 2
SINGLE PATTY
D.' I
APPROVED
NOA No.: 11-0124.04
Expiration Date: 05/10/12
Approval Date: 04/14/11
Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Nall through plastic cement
Paddy
(between tile)
Paddy
(under tile)
tat �• Single paddy
f � 31n. under tile
x3in.
Single paddy on
under-
lament
Single on top of file
course
In. X7 in. medium
site paddy save
Fascia course only
Nall through plastic cement
NMI through Mad: cement
Underlayment
Single paddy under tile
Single paddy between tile
2 In. x 71n. medium
sirs paddy eave
course only
v- in.x3in.
Single din. %.
paddyon
under -
layment
Shrgte paddy
on top of tale
gibCenrae
Fascia
Weephoie
Eave closure
Drip edge
Single paddy
between tile
1n.x 3 in.
Single paddy
on underlayment
Single paddy
on top of the
Eave Course
Eave Closers
2In. x 71n. medium
Fascellm paddy eave course only
ia
END OF THIS ACCEPTANCE
NOA No.: 11- 0124.04
Expiration Date: 05/10/12
Approval Date: 04/14/11
Page 7 of 7
MIAMID
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI -DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375 -2908
Monier Lifetile, LLC
200 Story Road
Lake Wales, FL 33898
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Vanguard Roll Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTLSEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.. 07- 1023.07
Expiration Date: 12/16/12,
Approval Date: 12/20/07
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category:
Sub- Category:
Material:
Roofing
Low Profile Roofing Tiles
Concrete
1. SCOPE
This renews a system using Monier Lifetile Vanguard Roll Concrete Roof Tile, as
manufactured Monier Lifetile LLC in Pompano Beach, FL. and described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by
applicable Building Code does not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Monier Lifetile LLC
Vanguard Roll Tile
Trim Pieces
Test
Dimensions Specifications
1= 16 -1/2" TAS 112
w= 13"
'/2" thick
1= varies
w = varies
varying thickness
2.1 SUBMITTED EVIDENCE:
Test Agency
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
TAS 112
Test Identifier
Product
Description
Low profile, interlocking, high pressure
extruded concrete roof tile equipped with one
nail hole and double roll ribs. For direct deck
or battened nail -on, mortar or adhesive set
applications.
Accessory trim, concrete roof pieces for use
at hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Test Name/Report
7161 -03 Static Uplift Testing
Appendix III PA 102 & PA 102(A)
7161 -03 Wind Tunnel Testing
Appendix II PA 108 (Nail -On)
P0402 Withdrawal Resistance Testing of
screw vs. smooth shank nails
94 -060B Static Uplift Testing
PA 101 (Adhesive Set)
94-084 Static Uplift Testing
PA 101 (Mortar Set)
P0631 -01 Wind Tunnel Testing
PA 108 (Mortar Set)
Date
Dec. 1991
Dec. 1991
Sept. 1993
March, 1994
May 1994
July 1994
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 2 of 7
Test Agency
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Nutting Engineering
Test Identifier
Letter Dated Aug. 1,
1994
Project No. 307025
Test #MDC -76 ❑
25- 7183 -1
25- 7183 -2
25- 7214 -2
25- 7214 -6
528454 -2 -1
520109 -2
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
TAS -112
Test Name/Report
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Driven Rain
PA 100
Static Uplift Testing
PA 102
(2 Quik -Drive Screws, Direct
Deck)
Static Uplift Testing
PA 102
(2 Quik -Drive Screws, Battens)
Static Uplift Testing
PA 102
(1 Quik -Drive Screw, Direct Deck)
(1 Quilt Drive Screw, Battens)
Static Uplift Testing
PA 101
Aerodynamic Multiplier
25 -7183
25 -7094
25 -7496
25 -7584
25- 7804b -8
25- 7804 -4 & 5
25- 7848 -6
Aerodynamic Multipliers
Two Patty Adhesive Set System
13343.1
Date
Aug. 1994
Oct. 1994
Feb. 1995
Feb. 1995
March, 1995
Sep. 1998
Dec. 1998
August 2007
March 1995
February 1996
April 1996
December
1996
October 2007
April 1999
June 2007
NOA No.: 07- 102107
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 3 of 7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with RAS 106.
33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
4. INSTALLATION
4.1 Monier Lifetile Vanguard Roll Concrete Roof Tile and its components shall be installed in
strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (1 x w )
Tile Profile
Weight W (lbf)
Length -I (ft)
Width -w (ft)
Monier Lifetile Vanguard Roll
Tile
9.2
1.38
1.08
Table 2: Aerodynamic Multipliers -) ft3)
Tile
Profile
A. (ft3)
Batten Application
X (ft3)
Direct Deck Application
Monier Lifetile Vanguard-Roll Tile
0.266
0.289
Table 3: Restoring Moments due to Gravity - Ma
(ft -Ibf)
Tile
Profile
2 ":12"
3 ":12"
4 ":12"
5 ":12"
6 ":12"
7 ":12"
greater
Battens
or
Direct
Deck
Monier
Lifetile
Vanguard
Roll Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
5.30
6.03
5.24
5.97
5.16
5.87
5.05
5.75
4.92
5.60
4.78
5.44
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
r i + 3
a
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15132"
plywood)
Direct Deck
(min. 19132"
plywood)
Battens
Monier Lifetile
Vanguard Roll
Tile
2 -10d Ring Shank Nails
27.8
37.4
28.8
1 -10d Smooth or Screw
Shank Nail
8.8
11.8
4.1
2 -10d Smooth or Screw
Shank Nails
16.4
21.9
7.1
1 #8 Screw
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1 -10d Smooth or Screw
Shank Nail (Field Clip)
24.3
24.3
24.2
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
19.0
19.0
22.1
2 -10d Smooth or Screw
Shank Nails (Field Clip)
35.5
35.5
34.8
2 -10d Smooth or Screw
Shank Nails (Eave Clip) _
31.9
31.9
32.2
Table 6: Attachment Resistance Expressed as a Moment Mf (ft -Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Monier Lifetile Vanguard Roll Tile
Adhesive'
26.12
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 11.4 grams.
Polyfoam Product, Inc. Average weight per patty 8 grams.
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Monier Lifetile Vanguard
Roll Tile
Polyfoam PolyProT""
86.61'
Polyfoam PolyProlN
45.54
3 Large paddy placement of 54grams of PolyProTM .
4 Medium paddy placement of 24grams of PolyProTM.
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 5 of 7
Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Monier Lifetile Vanguard Roll Tile
Mortar Set°
20.60
5 See specific mortar manufacturers Notice of Acceptance
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
shown below, or following statement "Miami -Dade County Product Control Approved ".
VANGUARD ROLL
MONIERLIFETILE LLC, VANGUARD ROLL TILE IDENTIFICATION MARK
(POMPANO, FL PLANT)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building
code in order to properly evaluate the installation of this system.
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 6 of 7
I
PROFILE DRAWING
MONIER LIFETILE VANGUARD ROLL CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12 /20/07
Page 7 of 7