RF-11-1707Permit Number: RF -9 -11 -1707 I Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 t,,ILV3C4' inspection Number: INSP - 164578 Inspection Date: December 02, 2011 Inspector: Bruhn, Norman Owner: GARRIDO, MANUEL Job Address: 688 NE 101 Street Miami Shores, FL 33138- Project: <NONE> Permit Type: Roof Inspection Type: Final Work Classification: Hurricane Mitigation Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Phone Number Parcel Number 1132060172070 Phone: 305 - 757 -2612 Building Department Comments INSTALL RIGHT ANGLE GUSSETS PER NEW MITIGATION Passe /& Inspector Comments Failed Correction Needed _ Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until December 02, 2011 For Inspections please call: (305)762 -4949 Page 1 of 1 F•I•E• FLORIDA INTERNATIONAL ENGINEERING &TESTING LAB INSIOHT•INNOVATION•INTEGRATION Florida International Engineering and Testing Lab LLC 16701SW 117 Avenue, Miami, FL 33177 Telephone: (305) 378 -1991 -Fax: (305 378 -1997 Miami -Dade Lab Certification # 07-0612.1X-State of Florida ca #27273 11 -30-11 ROOF RETROFIT. Section 553.844 Florida Statutes. Address: 688 NE 101 St., Miami Shores, FI. This is an inspection report, not a guarantee. Areas inspected: Roof to Wail connections were observed by means of roof opening at the time of supplemental installation. Observations: 1. Roof framing consists of 2 "x8" rafters @ 16" o.c. in the flat roof and 2 "x10" rafters @ 16" o.c. in the pitched roof. 2. Dade County approved Right angle Simpson Gussets Type HGAM 10 were installed at each end of rafter with 4 — 3 -1/2 "x X" Tap cons into Concrete tie beam at ea. end and 4- 1 -1/4" x#14 wood screws on ea. end of rafter as a supplement to existing STL Straps at every other rafter. All rafters have supplemental anchoring as hereby described. Conclusion: Anchoring to masonry wall as per Section 201.3 (concrete tie beam) properly fastened over each end of rafters capable of providing a minimum uplift capacity of 500 Ibs, as specified in table 201.3 and complies with the mandated roof -to -wall retrofit requirements of Section 553.844 Florida Statutes. f/.3 -/) Mr. Vinayagar M. Balakrishnan V, P.E. Fla. Reg. No.: 63107 AAA Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING OWNER: ee Simple Titleholder): l �1. t C 1 (CI1 1 d Phone #: 3 �i/a — ° X3 Address: / j e. l u l Zip: ? 136 Phone#: Permit No. t n 11 (4. Master Permit N City: L-( State: Tenant/Lessee Name: Email: JOB ADDRESS: fit-! 0 h K_- L 1 1 City: Miami Shores Folio/Parcel #: t 1 3- c;L (47 : t 1 Is the Building Historically. Designated: Yes Co� ty: (2) Miami Dade Zip: NO Flood Zone: CONTRACTOR: Company Name:d? -e u 0 L; V (�'' � Phone #: �U�— 7�� — 1a 7 State:( Zip:J. (,J Phone #: 6:5 7 s7 Address: 4 City: L( Qualifier Name: e State Certification or Registration #. Contact Phone #: k^ a C� 2 7 ' iL Email Address: Certificate of Competency #: �' �� fir' �,1✓ °° ��—. DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ l .,, gk /1 ► Square/Linear Footage of Work: 3 & Type of Work: ❑Address ❑Alteration lDescription of Work: _J 1-/ ,,; ❑New i ❑R air/Replace ❑Demolition .,,i/A •/ ),11 9/c 6 cis' -ei-, pc,it. 0-4/ 11- , A._ti , s e/ ii.--f 4 A 4 / & COLOR THROUGH ROOF TILE JS REQUItED acknowledged by: moo water ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* * * * * * * ** * * * * * * * * * * * * * ** * * * * * * ** Submittal Fee $ Permit Fee $ J ® / Z/ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ �. Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. l Owner or Agent Contractor The for oing instrument was acknowledged before e this/ The for oing i strument wa., acknowledged before me this ��' day o `' / , 2d) , by /70/ el (O r c , day o ��' � , 20 , by e ' he �-� who is per onally kno me or who has produced As identification and who did take an oath. NOTARY PUBLj(5: moo- ref i 2-e" Sign: Print: My Commission Ex APPROVED BY PUIEMBir y .,pl 18g1311► P - .0 ev 4k (Revised vfd0/ 07)(Rg).i5ed..06 /10 /2009)(Revised 3/15/09)(rev6/4/10) who is personally known -t or who has produced as identification and who did take an oath. NOTARY PUBLIC: ri. 1 Sign: - 1-e= Print: My C * * * *** * * * * * * * * * * * * * ** * * ** l.Coffiu,i� ;;fail �� 3 gt1r9: '=� 11,i� Plans Examiner Zoning Structural Review Clerk SIM200802 Used for Florida State Wide Product Approval # FL11473 Products on this Report which are approved: Product FL# Product FL# DETAL20 11473.1 LGUM210 -2 -SDS 11473.12 FGTR 11473.2 LGUM210 -3 -SDS 11473.13 FGTRE 11473.2 LGUM210 -4 -SDS 11473.14 FGTRHL 11473.2 LGUM26 -2 -SDS 11473.12 FGTRHR 11473.2 LGUM26 -3 -SDS 11473.13 HETA12 11473.3 LGUM26 -4 -SDS 11473.14 HETA16 11473.3 LGUM28 -2 -SDS 11473.12 HETA20 11473.3 LGUM28 -3 -SDS 11473.13 HETA24 11473.4 LGUM28 -4 -SDS 11473.14 HETA40 11473.4 LGUM410 -SDS 11473.15 HETALI2 11473.5 LGUM46 -SDS 11473.15 HETAL16 11473.5 LGUM48 -SDS 11473.15 HETAL20 11473.5 LTA1 11473.16 HGAM 10 11473.6 META12 11473.17 HGUM5.25 11473.7 META14 11473.17 HGUM5.50 11473.7 META16 11473.17 HGUM7.00 11473.8 META18 11473.1 HGUM7.25 11473.8 META20 11473.1 IT HGUM9.00 11473.8 META22 11473.1 HHETA12 11473.9 META24 11473. HHETAI 6 11473.9 META40 11473 HHETA20 11473,9 MSTAM24 1147 HHETA24 11473.10 MSTAM36 11473 HHETA40 11473.10 MSTCM40 11473. HM9 11473.6 MSTCM60 11473.19 HTSM16 11473.11 MTSM16 11473.2 HTSM20 11473.11 MTSM20 11473.2 0-7.2)1 3FA SEP 2 0 2011 SIMPSON SIMPSON STRONG -TIE COMPA Miami Shores Village .APPROVED .,... &Y DATE ZONING DEPT F}1_DG DEPT �!� G' " / 910i/ yi lk-TO COMPLIANCE WITH ALL Y II.VVAND FEDERAL !;',A11 COUNTY RULES AND REGULATIONS Jax Apex Technology, Inc. FBPE CA NO. 7547 4745 Sutton Park Court, Suite 402 Jacksonville, FL 32224! 9041821 -5200 Evaluation reports are the opinion of the engineer who prepared the report, based on the findings, and in no way constitute or imply approval by a local building authority. The engineer, in review of the data submitted, finds that, in his opinion, the product, material, system, or method of construction specifically identified in this report conforms with or is a suitable alternate to that specified in the Florida Building Code, SUBJECT TO THE LIMITATIONS IN THIS REPORT Jeffrey P. Arneson, an employee of Jax Apex Technology, Inc. (Apex Technology), is the authorized evaluating engineer of this report. Apex Technology is the prime professional, as defined in Florida Rule 61 G- 30.002, authorized to sell the engineering services performed by Jeffrey P. Arneson, and is in no way acting, nor attempting to act, as an approved evaluation entity. Neither Jeffrey P. Arneson, nor any other employee of Apex Technology, has performed calculations or testing for the products listed in this report. This evaluation is based solely upon the review, under the direct supervision of Jeffrey P. Arneson, of testing and/or calculations submitted by the manufacturer. The capacities listed in this report are based on the limiting capacities as determined from the substantiating data. We reviewed the substantiating data to a degree that allowed us to determine whether or not the work performed is consistent with the intended use of the product, and that the methods used are in compliance with, or meet the intent of, the Florida Building Code. All test reports were prepared by an approved testing laboratory. REPORT NO.: SIM200802 CATEGORY: Structural Components SUB CATEGORY: Metal Connectors SUBMITTED BY: SIMPSON STRONG -TIE COMPANY, INC. 5956 W. LAS POSITAS BOULEVARD PLEASANTON, CA 94588 1. CERTIFICATION OF INDEPENDENCE: Jeffrey P. Arneson, the Florida engineer who prepared this report, and Apex Technology have no financial interest in the manufacturing, sales, or distribution of the products included in this report. Jeffrey P. Arneson and Apex Technology comply with all criteria as stated in Florida Administrative Code Chapter 9B- 72.110. 2. PRODUCT NAME Truss to Wall Connectors MTSM16, MTSM20, HTSM16, HTSM20, HM9, HGAM10 Page 1 of 13 Simpson Strong -Tie Embedded Truss Anchors META12, META14, M ETA16, M ETA18, M ETA20, META22, META24, M ETA40, HETA12, HETA16, HETA20, HETA24, HETA40, HETAL12, HETAL16, HETAL20, HHETA12, HHETA16, HHETA20, HHETA24, HHETA40, LTA1, DETAL Wood to Masonry Straps MSTAM24, MSTAM36, MSTCM40, MSTCM60 Girder Tiedowns FGTR, FGTRE, FGTRHL, FGTRHR Wood to Masonry Hangers LGUM26 -2, LGUM28 -2, LGUM210 -2, LGUM26 -3, LGUM28 -3, LGUM210 -3, LGUM26 -4, LGUM28 -4, LGUM210 -4, LGUM46, LGUM48, LGUM410, HGUM5.25, HGUM5.50, HGUM7.00, HGUM7.25, HGUM9.00 3. SCOPE OF EVALUATION Load Evaluation as a Structural Component using the requirements of the Florida Building Code, Building. 4. DESCRIPTION: 4.1 MTSM16 and MTSM20 Twist Straps for Wood to Masonry. The MTSM16 and MTSM20 are used to anchor wood trusses, rafters, or beams to masonry or concrete walls. The MTSM fastens to the wood member with 10d common nails, and fastens to the wall with either 1/4x21/4" Titen Masonry Screws for a masonry wall, or' /4x13 " Titen Masonry Screws for a concrete wall. These connectors are manufactured from 16 gauge steel meeting ASTM A653 SS Grade 33. The galvanized coating complies with the G90 requirements of ASTM A653. Twist strap fastener schedules, dimensions and allowable Toads are shown in Table 1. See Figure 1 for additional details of twist straps for masonry. 4.2 HTSM16 and HTSM20 Twist Straps for Wood to Masonry. The HTSM16 and HTSM20 are used to anchor wood trusses, rafters, or beams to masonry or concrete walls. The HTSM fastens to the wood member with 10d common nails, and fastens to the wall with either 1/4x21/4" Titen Masonry Screws for a masonry wall, or 1 /4x13/4" Titen Masonry Screws for a concrete wall. These connectors are manufactured from 14 gauge steel meeting ASTM A653 SS Grade 50, Class 1. The galvanized coating complies with the G90 requirements of ASTM A653. Twist strap fastener schedules, dimensions and allowable loads are shown in Table 1. See Figure 1 for additional details of twist straps for masonry. 4.3 HM9 Hurricane Tie. The HM9 is used to anchor wood trusses, rafters, or beams to masonry or concrete walls. The HM9 fastens to the wood member with Simpson 1/4 X 11/2" SDS screws (provided with the part), and fastens to the wall with either 1/4x21/4" Titen Masonry Screws for a masonry wall, or '/4x13/4" Titen Masonry Screws for a concrete wall. The HM9 is manufactured from 18 gauge steel meeting ASTM A653 SS Grade 33. The galvanized coating complies with the G90 requirements of ASTM A653. Hurricane tie fastener schedule, dimensions and allowable Toads are shown in Table 1. See Figure 2 for additional details of the HM9. 4.4 HGAM10 Hurricane Gusset Angle. The HGAM10 is used to anchor wood trusses, rafters, or beams to masonry or concrete walls. The HGAM10 fastens to the wood member with Simpson 1/4 X 1'/z" SDS screws (provided with the part), and fastens to the wall with 1/4)(2W Titen Masonry Screws. Allowable loads are shown in Table 2. The HGAM10 is manufactured from 14 gauge steel meeting ASTM A653 SS Grade 33. The galvanized coating complies with the G90 requirements of ASTM A653. Angle Page 2 of 13 Simpson Strong -Tie fastener schedule, dimensions and allowable Toads are shown in Table 1. See Figure 3 for additional details of the HGAM10. 4.5 META, HETA, HETAL, HHETA Embedded Truss Anchors. Embedded Truss Anchors are used to anchor a wood member (usually a truss) to a masonry or concrete wall. Embedded truss anchors fasten to a single -ply wood truss with 10dx1 Y2 nails or to a multiple -ply truss with 16d common nails. They are embedded in the masonry or concrete wall to a depth indicated on the side of the anchor (4" for META, HETA, and HETAL, and 5' /16" for HETAL). The strap portion of the anchor is 11/2' wide. The anchors are manufactured from steel meeting ASTM A653 SS Grade 50, Class 1, with the exception of the truss seat of the HETAL which is manufactured from steel meeting ASTM A653 SS Grade 33. Steel thickness is as specified in Table 9. The galvanized coating complies with the G90 requirements of ASTM A653. Embedded truss anchor fastener schedule, dimensions and allowable loads are shown in Table 2 for single installations and Table 3 for double installations. See Figures 4 and 6 for additional details of single and double embedded truss anchors. 4.6 LTA1 Lateral Truss Anchor. The LTA1 is used to anchor wood trusses, rafters, or beams to masonry or concrete walls. The LTA1 fastens to the wood member with 10dx11/2" common nails and has legs which are embedded into the wall system. Allowable loads are shown in Table 2. The LTA1 is manufactured from 18 gauge steel meeting ASTM A653 SS Grade 33. The galvanized coating complies with the G90 requirements of ASTM A653. Truss anchor fastener schedule, dimensions and allowable loads are shown in Table 2. See Figure 5 for additional details of the LTA1. 4.7 DETAL20 Double Embedded Truss Anchor. The DETAL is a high capacity connector used to anchor single -ply wood trusses or rafters to masonry or concrete walls. The DETAL fastens to the wood members with 10dx1Y2" nails. They are embedded in the masonry or concrete wall to a depth of 4'/ inches. The strap portion of the anchor is 11/2" wide. The strap anchors are manufactured from steel meeting ASTM A653 SS Grade 50, Class 1, and the truss seat is manufactured from steel meeting ASTM A653 SS Grade 33. The strap anchors are 16 ga. steel and the seat is 18 ga. steel. The galvanized coating complies with the G90 requirements of ASTM A653. Embedded truss anchor fastener schedule, dimensions and allowable loads are shown in Table 3. See Figure 6 for additional details of the DETAL. 4.8 MSTAM, MSTCM Wood to Masonry Strap Tie. The MSTAM and MSTCM Strap Tie models are used to provide a tension connection between wood members and a masonry or concrete structure. The MSTAM Straps are 1 1/4" wide for use on 11/2" and larger members. They are installed with 10d common nails to the wood and either '/4x2'/" Titen Masonry Screws to masonry, or 1/4x13/4" Titen Masonry Screws to concrete. The MSTCM Strap is 3" wide for use on doubled 2 -by or single 4 -by and larger members. They are installed with 16d sinker nails to the wood and either 1/4x2'/4" Titen Masonry Screws to masonry, or 1 /4x13/4" Titen Masonry Screws to concrete. The MSTCM Strap has countersunk nail slots for a lower nailing profile and coined edges for safer handling. The straps are manufactured from steel meeting ASTM A653 SS Grade 50, Class 1, of a thickness as specified in Table 4. The galvanized coating complies with the G90 requirements of ASTM A653. Masonry strap fastener schedule, dimensions and allowable loads are shown in Table 4. See Figure 7 for additional details of wood to masonry straps. 4.9 FGTR, FGTRE, FGTRHL, FGTRHR Face Mount Girder Tie Down. The FGTR is a non -pitch specific girder tie down that can be used in new construction or retrofit applications to tie down a girder truss or beam to a concrete or masonry wall. The Page 3 of 13 Simpson Strong -Tie FGTR can be installed in a single application or can be doubled to achieve a higher uplift capacity. The FGTR fastens to the truss with Simpson Strong -Tie SDS' /4' wood screws, and fastens to the masonry or concrete wall with Simpson Strong-Tie 1/2" diameter Titen HD fasteners, which are supplied with the connector. The FGTRE uses a strap that is oriented with its flat dimension parallel to the truss for placement at the end of walls when the truss is parallel to the wall. The FGTRHL and FGTRHR are designed with the flat dimension of the strap at a 45 degree angle to the truss for anchorage of hip trusses. The FGTR straps are manufactured from 7 gauge ASTM A- 1011 Grade 33 steel having Fy =33ksi and Fu =52ksi and the plates are made from 3 gauge ASTM A -1011 Grade 33 steel having Fy =33ksi and Fu= 52ksi. They have a gray powder coat finish. Girder tie down fastener schedule, dimensions and allowable Toads are shown in Table 5. See Figure 8 for additional details of face mount girder tie down connectors. 4.10 LGUM, HGUM Masonry Girder Hangers. LGUM and HGUM girder hangers are high capacity joist hangers that are used to connect wood girders and beams to masonry or concrete walls. The LGUM and HGUM use Simpson Strong -Tie Titen HD anchors to attach to the masonry or concrete wall, and Strong -Drive Screws (which are provided) to attach the beam to the hanger. To install the Titen HD anchors, drill holes of the same diameter as the anchor into the masonry or concrete. Holes should be' /" deeper than the specified Titen HD length. The SDS screws are installed best with a low -speed 1/2" drill and a %" hex head driver. Predrilling holes for SDS screws is not required. The LGUM is manufactured from galvanized steel complying with ASTM A 653 SS Grade 40 with minimum yield and tensile strengths of 40 and 55 ksi (275 and 379 MPa), respectively. The HGUM is manufactured from galvanized steel complying with ASTM A 653 SS Grade 33 with minimum yield and tensile strengths of 33 and 45 ksi (228 and 310 MPa), respectively. The galvanized coating complies with the G90 requirements of ASTM A 653. The steel thicknesses are 0.099" (2.51 mm) for the LGUM, and 0.173" (4.39 mm) for the HGUM. Girder hanger fastener schedule, dimensions and allowable Toads are shown in Table 6. See Figure 9 for additional details of masonry girder hangers. 5. MATERIALS 5.1 Steel. Steel specifications for each product listed in this evaluation report shall be as indicated in the previous section. 5.2 Wood. Wood members to which these connectors are fastened shall be solid sawn lumber, glued - laminated lumber, or structural composite lumber having dimensions consistent with the connector dimensions shown in Tables1 through 6. Unless otherwise noted, lumber shall be Southern Pine or Douglas Fir -Larch having a minimum specific gravity of 0.50. Where indicated by SPF, lumber shall be Spruce - Pine -Fir having a minimum specific gravity of 0.42. 5.3 Nails and Bolts. Unless noted otherwise, nails shall be common nails. Nails shall comp Common Nail Pennyweight Nail Shank Diameter (inch) Fyb (psi) 10d 0.148 90,000 16d sinker 0.148 90,000 16d 0.162 90,000 Fasteners for galvanized connectors in pressure - preservative treated wood shau ne hot - dipped zinc coated galvanized steel with coating weights in accordance with ASTM A153. Fasteners for stainless steel connectors shall be stainless steel. Page 4 of 13 Simpson Strong -Tie 5.4 Concrete /Masonry. Concrete and Masonry design specifications shall be the stricter of the specifications by the engineer of record, the Florida Building Code minimum standards, the following, or as noted in the report: Material Specification Minimum Compressive Strength Concrete, f'c - 2500 psi Masonry, fm ASTM E447 1500 psi Masonry Unit ASTM C90 1900 psi Mortar ASTM C270 Type S 1800 psi (or by proportions) Grout ASTM C476 2000 psi (or by proportions) 6. INSTALLATION Installation shall be in accordance with this report and the most recent edition of the Simpson Strong -Tie Wood Construction Connectors catalog. The Information in this report supercedes any conflicting information between information provided in this report and the catalogue. 7. SUBSTANTIATING DATA Test data submitted by Testing Engineers Inc. and Product Testing, Inc., and signed and sealed calculations performed by Jeremy Gilstrap, P.E., and Samuel Hensen, P.E., performed in accordance with the 2007 Florida and Residential Building Codes. Product Test Number Date Tested MTSM B845, H756 2/27/90, 12/6/00 HTSM 02 -3667 1/30/02 HM9 Uplift 02 -3793 5/15/02 HM9 F1 Direction 02 -3793 5/15/02 HM9 F2 Direction 02 -3793 5/15/02 HGAM10 Uplift 02 -3884 7/29/02 HGAM 10 F1 Direction H046 3/25/99 HGAM10 F2 Direction H141 6/22/99 META Uplift 02 -3674, 02 -3802, 02 -3861, 04 -4675 6/4/02, 6/8/02, 7/24/02, 2/8/04 META F1 02 -3674, 02 -3802 6/4/02, 6/8/02 META F2 02-3674, 02 -3802, 02 -3861 6/4/02, 6/8/02, 7/24/02 HETA Uplift 02 -3803, 02 -3862, 04 -4676 6/10/02. 7/26/02, 2/8/04 HETA F1 02 -3803 6/10/02 HETA F2 02 -3803, 02 -3862 6/10/02, 7/26/02, HHETA Uplift 02 -3676, 02 -3863, 04 -4674 6/4/02, 7/29/02, 2/7/04 HHETA F1 02 -3676 6/4/02 HHETA F2 02 -3676, 02 -3863 6/4/02, 7/29/02 HETAL Uplift 02 -3803, 02 -3862, 04 -4676 6/10/02, 7/26/02, 2/8/04 HETAL F1 0793 3/17/94 Page 5 of 13 Simpson Strong -Tie Product Test Number Date Tested HETAL F2 D844 3/28/94 DETAL Uplift 0797 3/28/08 DETAL F1 0795, 0799 5/12/08, 3/27/08 DETAL F2 0796, 0798 6/05/08 3/28/08 LTA1 Uplift 02 -3616 2/13/02 LTA1 F1 02 -3616 2/13/02 LTA1 F2 02 -3616 2/13/02 MSTAM24 Uplift 02 -3795 5/17/02, 5/17/02 MSTAM36 Uplift 02 -3795 5/17/02, 5/17/02 MSTCM40 Uplift 02 -3796 5/31/02 MSTCM60 Uplift N471 1/26/07 FGTR Uplift 04 -5004, 04 -5005 10/6/04, 10/6/04 FGTRE Uplift 04 -5010 10/29/04 FGTRHLJR Uplift 04 -4915 10/13/04 LGUM Down M202,M 203, M204, M222, M224 7/13/06, 7/13/06, 7/13/06, 7/14/06, 8/03/06 LGUM Uplift M211, M212, M213 8/18/06,8/18/06, 8/21/06 HGUM Down M207, M209,M216, M217 9/11/06, 9/11/06, 10/20/06, 10/20/06 HGUM Uplift M729, M731 8/3/06, 8/04/06 8. FINDINGS Upon review of the data submitted by Simpson Strong -Tie, it is my opinion that the models as described in this report conform with or are a suitable alternative to the standards and sections in the 2007 Florida Building Code, Building, and the Florida Building Code, Residential code editions listed in section 10 of this report, subject to the limitations below. Maximum allowable loads shall not exceed the allowable loads listed in this report. 9. LIMITATIONS: 1. Maximum allowable Toads shall not exceed the allowable Toads listed in this report. Allowable loads listed in this report are based on allowable stress design. The loads in this report are not applicable to Load and Resistance Factor Design. 2. Capacity of wood members is not covered by this report. Capacity of wood members must be checked by the building designer. 3. Allowable loads for more than one direction for a single connection cannot be added together. A design load that can be divided into components in the directions given must be evaluated as follows: Design Uplift /Allowable Uplift + Design Lateral Parallel to Plate /Allowable Lateral Parallel to Plate + Design Lateral Perp. to Plate /Allowable Lateral Perp. to Plate < 1.0 10. CODE REFERENCES Florida Building Code, Building 2007 Edition Section 104.11 Alternate Materials and Methods Chapter 1714.2 Load Test Procedure Specified Chapter 21 Masonry Chapter 22 Steel Chapter 23 Wood Page 6 of 13 Simpson Strong -Tie Florida Building Code, Residential 2007 Edition R101.2.1 Scope R4407 HVHZ Masonry R4408 HVHZ Steel R4409 HVHZ Wood 11. ALLOWABLE LOADS: The tables that follow reference the allowable loads for the aforementioned products. TABLE 1 ALLOWABLE LOADS AND FASTENERS FOR TRUSS TO MASONRY OR CONCRETE WALL CONNECTORS Model No: ... Length: • Allo�ua Truss/Rafter MU Ite,ri Cpnorete:; ble Upl (1:6 Sattfherri i.ne /Douglps 1 a €.cfi: .................... Fir,;. MTSM16 16 16 7 -10d 4-'/4x2'/4 4- '/4x1% 875 755 MTSM20 16 20 7 -10d 4-1/4x21/4 4 -'/4x 13/4 875 755 HTS M 16 14 16 8 -10d 4- '/4x2'/ 4- '/4x13/4 1175 1010 HTS M20 14 20 10 -10d 4- '/4x2'/4 4- '/4x13/4 1175 1010 HM92 18 4- SDSY4X1 %2 5-'/4x2'/4 5- '/4x13/4 805 690 HGAM 103.6 14 4- SDS'/X1 4- '/x2'/4 4- '/4x2'/4 850 850 Notes: 1. Loads include a 60% load duration increase on the fastener capacity for wind loading where allowed by the Florida Building Code. Loads do not include a stress increase on the strength of the steel. No further increases are permitted. Reduce loads where other loads govem. 2. HM9 allowable F1 load shall be 635 lbs (DFUSYP) & 545 lbs (SFP), and allowable F2 load shall be 200 Ibs (DFL /SYP) & 170 Ibs (SPF). 3. HGAM10 allowable F1 load shall be 1005 lbs (DFL /SYP) & 870 Ibs (SFP), and allowable F2 load shall be 1105 Ibs (DFUSYP) & 950 Ibs (SPF). 4. Allowable loads for the HGAM10 are for one connector. A minimum rafter thickness of 2'/" must be used when framing anchors are installed on each side of the joist or truss. MoisRUta:lki�t not shown Figure 1 Typical MTSMM /HTSM Application Page 7 of 13 Figure 2 Typical HM9 Installation Figure 3 Typical HGAM10 - Installation Simpson Strong -Tie TABLE 2 ALLOWABLE LOADS AND FASTENERS Uplid.: .....::: Lateral :Loads INQde! No Ga H ' 1 P(y $o Pine Truss 2 or 3 Ply a t�rn• e Tru55.:... F t E� ilelTo Fh �eryen 2a ;' ... X0§, tertbrs. Load , _Festenefs Load META12 8 7- 10dx1%2 1450 6 -16d 1450 340 725 META14 18 10 7- 10dx1%2 1450 6 -16d 1450 340 725 META16 12 7 -10dxl %2 1450 6 -16d 1450 340 725 META18 14 7- 10dx1%2 1450 6-16d 1450 340 725 META20 16 6- 10dx1%2 1270 5 -16d 1245 340 725 7- 10dx1%2 1450 6 -16d 1450 340 725 META22 18 7- 10dx1% 1450 6 -16d 1450 340 725 META24 20 7- 10dx1%2 1450 6 -16d 1450 340 725 META40 36 7- 10dx1'% 1450 6 -16d 1450 340 725 HETA12 16 8 7 -10dx1 %2 1520 7 -16d 1780 340 725 HETA16 12 9 -10dx1 %2 1810 8 -16d 1810 340 725 HETA20 16 8- 10dx1 %2 1735 7 -16d 1780 340 725 9- 10dx1+/2 1810 8 -16d 1810 340 725 HETA24 20 9- 10dxl'A 1810 8 -16d 1810 340 725 HETA40 36 9- 10dxl% 1810 8 -16d 1810 340 725 HHETA12 14 8 7 -10dx1 %2 1565 7 -16d 1820 3406 815 HHETA16 12 10- 10dx1%2 2235 9 -16d 2235 3406 815 HHETA20 16 9- 10dx1%2 2010 8 -16d 2080 3406 815 10- 10dx1%2 2235 9-16d 2235 3406 815 HHETA24 20 10- 10dx1'/2 2235 9 -16d 2235 3406 815 HHETA40 36 10- 10dx1'/2 2235 9 -16d 2235 3406 815 HETAL12 16 7 10- 10dx1'/2 1085 10-16d 1270 415 1100 HETAL16 11 14- 10dx1'/2 1810 13-16d 1810 415 1100 H ETAL20 15 14 -10dx 1'/. 1810 13-16d 1810 415 1100 LTA1 18 31/6 12 -10dx1 %2 1420 12 -10dx1 %2 1420 485 1425 Notes: 1. Loads include a 60% load duration increase on the fastener capacity in wood for wind loading where allowed by the Florida Building Code. Loads do not include a stress increase on the strength of the steel. No further increases are permitted. Reduce loads where other loads govem. 2. Five nails must be installed into the truss seat of the HETAL 3. Parallel - to-plate load towards face of HETAL is 1975 lbs. 4. Minimum fc is 2,000psi 5. It is acceptable to use a reduced number of fasteners in a product provided that there is a reduction in load capacity. The load per nail can be approximated by dividing the allowable load by the number of fasteners. This concept applies to all member sizes. There should be a minimum of 4 nails installed in the strap. Lateral loads do not apply when fewer than 7 fasteners are used with the HETA and HHETA anchors or less than 6- 16d or 7- 10dx1'W fasteners are used with the META anchor. 6. The HHETA allowable F1 load can be increased to 435 pounds if the strap is wrapped over the truss and a minimum of 12 nails are installed. lyliirel META Installed with TSS Figure 4 META/HETA/HHETA Typical Installation Figure 5 LTA1 Typical Installation Simpson Strong -Tie TABLE 3 ALLOWABLE LOADS AND FASTENERSFOR DOUBLE EMBEDDED TRUSS ANCHORS Model No; a " LI lift`! Loads Lateral Lnads6 1 Ply. outherrt >pine.TruSS:i ..: Fasteners Load 3; PIS Soothe pn 1ru s. Fasteners Load (parallel; tow ll }:. t4 wall)::.:, DETAL20 1 CMU 18 -10dx 1'/1 2480 20006 1370 Concrete META 2 CMU Concrete 18- 10dx1% 10 -10dx 1' /s 2480 2000 1505 1985 14 -16d 1900 1210 1160 10- 10dx1Y2 1985 14 -16d 2565 1210 1160 HETA 2 GMU Concrete 10 -10dx 11/2 2035 12 -16d 2500 1225 1520 10 -10dx 1'/z 2035 12 -16d 2700 1225 1520 HHETA 2 CMU Concrete 10- 10dx1% 2035 12 -16d 2500 1225 1520 10 -10dx 1' /z 2035 14 -16d 3350 1225 1520 Notes: 1. Loads nclude a 60% load duration increase on the fastener capacity in wood for wind loading where allowed by the Florida Building Code. Loads do not include a stress increase on the strength of the steel. No further increases are permitted. Reduce loads where other loads govern. 2. Minimum f', is 2,500 psi. 3. Install with spoons facing outward and spaced no more than 1/8" wider than the truss width. 4. Install half of the required number of fasteners in each strap, except for the DETAL20. For DETAL20, install six nails in each strap and six nails in the truss seat. 5. Lateral loads for META, HETA, and HHETA anchors apply only to 2- or 3 -ply applications with anchors spaced a minimum of 3" apart. For single ply applications use lateral loads in Table 2. DETAL lateral load apply to single -ply application. 6. DETAL20 Lateral Loading in the Fi direction anchored in CMU greater than 1,790 Ib. may result in deflection up to 5/32" in the F1 direction. htter (m ?RS Page 9 of 13 Typical Installation with tw.o.METs Figure 6 DETAL and Double METAIHETAJHHETA Application Simpson Strong -Tie TABLE 4 MASONRY STRAPS ALLOWABLE LOADS, FASTENERS AND DIMENSIONS Model Dirnenstons' Fiches) Sirnpson:Strong„ Tie Them' Sorews ..... . Concrete DF!SP its i. 6 MSTAM24 18 11/4 24 5-1/4x21/4 514x13/ 8 -10d 1500 9 -10d 1500 MSTAM36 16 11/4 36 8 -1/ x2'1 8 -%x13/ 10 -10d 1870 11 -10d 1870 MSTCM40 16 3 401/4 14-1/4x21/4 14- '/4x1'/4 22 -16d Sinker 4220 26 -16d Sinker 4220 MSTCM60 16 3 591A 14- 1/4x21/4 14- 1/4x11/4 26 -16d Sinker 4220 26 -16d Sinker 4220 Notes: 1. Loads include a 60% load duration increase on the fastener capacity in wood for wind loading where allowed by the Florida Building Code. Loads do not include a stress increase on the strength of the steel. No further increases are permitted. Reduce loads where other loads govern. 2. Minimum edge distance is 11/" for Titen Masonry Screws. 3. Minimum fm = 1500 psi and minimum fc = 2500 psi. 4. Products shall be installed such that the Titen screws are not exposed to moisture. 0.n R14413 laiSTCM40 Page 10 of 13 Typica MSTA1136 Installation Figure 7 MSTAMIMSTCM Typical Dimensions and Installation Typical MSTCM60 Installation Simpson Strong -Tie TABLE 5 FGTR SERIES ALLOWABLE LOADS AND FASTENERS ...... ............................... . Nicsdeli'NQ. Fas 1.9 :Block artd: gsr>!+:ra° Wall Qw Uplift Lo FGTR 1 2 -Titen HD 1/2x5" 1 8 -SDS 1 /4x3 50006 2 4 -Titen HD 1/2x5" 36 -SDS 1 /4x3 9400 FGTRHLJR 1 2 -Titen HD 1/2x5" 18 -SDS1 /4x3 3850 FGTRE 1 2 -Titen HD 1/2x5" 1 8 -SDS 1 /4x3 46856 FGTRE +FGTR 1 Each 4 -Titen HD 1/2x5" 36 -SDS1 /4x3 50006 Notes 1. Loads include a 60% load duration increase on the fastener capacity in wood for wind loading where allowed by the Florida Building Code. Loads do not include a stress increase on the strength of the steel. No further increases are permitted. Reduce loads where other loads govern. 2. Products shall be attached to grouted and reinforced CMU walls or reinforced concrete walls that are designed to transfer the uplift loads to the foundation. 3. Minimum edge distance for the Titen HD is 4" 4. THD's should be spaced in every other hole on the part 5. Attached members must be designed to resist the applied loads 6. Products used for corner applications shall be limited to 4685 Ibs allowable 7. Loads are governed by the grouted wall capacity based on testing of the products attached to the corner of a block wall at an average ultimate load of 14,800 Ibs. The connector has been tested attached to a steel column to an allowable load of 11,400 Ibs which can be used for design provided the wall is designed by the engineer of record to transfer the uplift forces. •Two FGTFis: tST6 FGTRI L TOPVIEW Page 11 of 13 Figure 8 FGTR/FGTRE /FGTRHUFGRHR Typical Installation Simpson Strong -Tie TABLE 6 — LGUM AND HGUM ALLOWABLE LOADS, FASTENERS AND DIMENSIONS ar s ** :4000 lovable Loads (Ibs. Ga .. B ' MUfp+crete JOiSt Uplift i inlaad MFG ei1 HD: SDS S�rws (11 P /LVL1PSLiLSL�`'' Cencreto {100!115/125) DOUBLE 2x SIZES LGUM 26 -2 12 3 V1s 5 4 4 -% "x 4" 4 - '/4 "x 21/2" 1430 5595 LGUM 28 -2 12 3 ' /16 7 4 6 -% "x 4" 6 - %"x21/2" 2435 8250 LGUM 210 -2 12 3 ' /16 9 4 8 -%"x 4" 8 - %"x21/2" 3575 9575 TRIPLE 2x SIZES LGUM 26 -3 12 5 % LGUM 28 -3 LGUM 210 -3 12 5'% 12 5% 5% 7 % 9 1/n 4 4 4 4 - %" x 4" 6 -% "x 4" 8 - %" x 4" 4 -'/4 "x21/2' 6 -'/4 "x21/2' 8 - 1 /1 "x 2' /z' 1430 2435 3575 5610 8290 9715 QUADRUPLE 23( SIZES LGUM 26 -4 12 6 x' /16 5' /16 4 LGUM 28 -4 12 6 11/16 7 /16 4 4 -%"x 4" 6 -% "x 4" 4 - 1 /1 "x 21/2' 1430 5625 6 -1/4 "x21/2' 2435 8335 LGUM 210 -4 12 6 11/16 9 '/16 4 8 - % "x 4" 8 - 1 /4"x 2W/2" 3575 9860 4X SIZES LGUM46 12 35 4% 4 LGUM 48 12 35 6% 4 4 -%"x 4" 6 -% "x 4" 4 -1/1"x21/2" 6 -'/4"x 2'/2" 1430 5600 2435 8260 LGUM410 12 35 8Y 4 8 -% "x 4" 8- ' /4 "x2' /2" 3575 9620 ENGINEERED WOOD AND STRUCTURAL COMPOSITE LUMBER SIZES (HEAVY DUTY) HGUM5.25 7 51/4 HGUM5.50 HGUM7.00 HGUM7.25 HGUM9.00 7 9 7 5 '/ 7 7 7 7 1/4 11 to 30 5 1/4 8 - % "x 5" 24 - % "x 21/2" 10085 14965 16015 5 1/4 8 - 5 /d' x 5" 24- % "x2' /2" 10125 14940 16015 5 '/4 8 x 5" 24 -' /4 "x 21/2" 10375 14770 16015 5 % 8 -s "x 5" 24 - '/4'x2'/2' 10415 14740 16015 5 1/4 8 -%"x 5" 24 -' /4'x2' /z' 10705 14545 16015 Notes: 1. Uplift loads include a 60% load duration increase on the fastener capacity in wood for wind loading where allowed by the Florida Building Code. Loads do not include a stress increase on the strength of the steel. No further increases are permitted. Reduce loads where other loads govern. 2. Minimum fn, = 1500 psi and f,: = 2500 psi. MOS Page 12 of l3 kw:4 U11:§1::, 4Maim, Figure 9 LGUM /HGUM Typical Installation 4 Tim W fla:M Imst#14glt. Simpson Strong -Tie 12. IDENTIFICATION Each connector covered by this report shall be stamped with the manufacturer's name and /or trademark and the product name. Page 13 of 13 Simpson Strong -Tie