Loading...
MC-11-1041Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 167281 Permit Number: MC -6 -11 -1041 Scheduled Inspection Date: December 05, 2011 Inspector: Perez, JanPierre Owner: Job Address: 1297 NE 100 Street Miami Shores, FL Project: <NONE> Contractor: ALL YEAR COOLING AND HEATING Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132050080080 Phone: (954)566 -4644 Building Department Comments REPLACE 5 TON AC SYSTEM Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 160737. December 02, 2011 For Inspections please call: (305)762 -4949 Page 30 of 46 • Miami Shores Village Building Department f0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 Permit Type: Mechanical Owner's Name (Fee Simple Titleholder) JOHN J, BRADY 111 Owner's Address 1297 NE 100 ST Permit No. Master Permit No. JUN 0 REcv h'I C ((° IJt-q Phone # 305 - 758 -7006 City MIAMI SHORES State FL Zip 33138 Tenant/Lessee Name Phone # E -MAIL: Job Address (where the work is being done) 1297 NE 100 ST City Miami Shores Village County Miami -Dade Zip 33138 FOLIO / PARCEL # 11- 3205 - 008 -0080 Is Building Historically Designated YES NO Contractor's Company Name ALL YEAR COOLING & HEATING Phone # 954 - 5664644 Contractor's Address 6781 W. SUNRISE BLVD City PLANTATION State FL Zip 33313 Qualifier Name GRETA B. SMITH phone #954 -566 -4644 State Certificate or Registration No. CAC058160 Certificate of Competency No. CMC511 �i _H,• CMORGAN@AYCAIR.COM Architect/Engineer's Name (if applicable) NSA Phone # Value of Work For this Permit $ Jr Square / Linear Footage Of Work: Type of Work: DAddition DAlteration ❑New [e Repair/Replace ❑ Demolition Describe Work: REPLACE CENTRAL NC W/( Q,,k, S ` 14- & , I Ku) # I14-AT4t(ao AHOs e6HP it Submittal Fee $ 5-0 - Permit Fee $ CCF $ CO /CC Notary $ `��Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side -+ Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a buildingpermit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is i� . ed. In the absence of s _r posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature t�l1 Signature ab 11 J - Owner gent Contract° The foregoing instrument was acknowledged before me this 1 day of jww Q., , 20 l , by Groff. 3. ark , who is personally known to me or who has produced as identification and who did take an oath. The foregoing instrument was acknowledged before me this day of J Lts7.4., , 20 11 , by John Brcu2 who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: e Print: lltie► My Commission Expires: NOTARY PUBLIC -STATE OF FLORIDA -,•01".44., Cheryl Morgan Commission # DD897935 Expires: JLNE 28, 2013 DDNDED Tdxt. n 1 LAN PIC BONDING CO., INC. APPLICATION APPROVED BY: (Revised 02/08/06) NOTARY PUBLIC: NOTARY PUBLIC -STATE OF FLORIDA "" Cheryl Morgan Commission # DD897935 ••,,,,,,,,.•'` Expires: JUNE 28, 2013 Sign: Print: 7 My Commission Expires: * ** * * * * * *** * * * * * * *** * * * * ** Plans Examiner Engineer Zoning :: • Tarlay'eCerdad—Yasterdsy'sPrinex*, , CONTRACT 6781 W. Stinise Bouleitard; Plantatiuk.i, FL 33313 Phone: (954) 566-4644 Fix: (954) 667-1290 woiw.ayeaincom Est. 1973 with over 150,000 Installations IHCT - We hereby submit specifications for: . JZf Equipment Installation ' Di Indoor Air Quality El Other Au vol. matte vim furnish au pit, 111bOr Entd equlpment necessary to isallihde the sante dtetked above In ecoordenoe with the =Mons end wallah= Paled In Ns =tract Does not Include electrical upgrade unless stated. NAME JoInw) tos.11 ADDRESS c11 110 00+1" 5 Vitei-,."- CITY/STATFJZIP cat S PI 3 t 'E-MAIL. HOME PHONE 405'' CELL PHONE 1 2 3 INDOORAIR IMPROVEMENT:',-.,..: El Duct Cleaning, Sanffizing #— Vents # —of Duct Systerns LIV Light High Quality Air Filter Location • QUality AlrOleaner. ' -• Location. . • • :,',":1;:',:"•••4"•.,.:4:.:.,"?'.'kirc'.:1.:>.....".1:1'k.,'4--;'::;:f'..fiETLIFka.&;,.,.SU.PPLY-D.1.$TRIBUT.1 0N 0ModifyiNew Supply Duct(s) ONIodifyiNew Return Duct(s) Ei New Return Air Gal, Size:: • NEW EQUIPIVIENT New Stipply Grill, Size x Qty • • Seal Up Leaks In Ducts ft ty • • MOliffriallons:tifrOSUOOly. Pfritirn 0 • rdi Split System 1.2 Electric 1-teat ' O 0 Air, .Handler Breaker Wire Size Package Unit Straight Cool - Heat Pump Heat Recovery Unit .., # of Systems : : =1*" ..6.- .....„.121Pr.'.xis.YT.9.,..,ERePiace6 E".•'.1..•,T.'..... .T„'..:"..:r.:'",•;:i Attic • :., : • ...,... . 1-. Naw•Breaker Brand 7, , ... '.. •• .... ''' .... • , Horizontal APPlictiticd ' ' 71 VerticillApPlicition :- :i i: .• .1:. 0 Condenser Breaker Wire sfze 0 Other ,.. . ,..,.. ... „ .. :. ,OUse Existing . ;00BRraneplaced _. -If ''..::• -' • ." i -1 ' El New Breaker MAKE MODEL . •• SEER .: ., ., •- . ... . ,.. . ... .: Electrical nneet Box. • ..,...: ...::.... • ''''.:"*: ' -. • ' . • • ' • ,- 19N 144 • Provided By Ali YautIonling Existing Bechtel to Code Condensate Hook-UP ... 0 Priniary. .1!. • Seizindary „ New condensate Nov 0 ary' Dnain Pan: 0Refrigerant Copper Liquld Line, Size' g • • •• •••••• 211.1abilities and Workmen's Comp for Our Work Performed with Existing Codes .. • • .. , E,Mounting Hardware of Stand for Alr'Handler togiod' 4■2, Hurricane Cade Strapping I- IrPlne Float Switch Auxiliary Float Safety Switch Type of Thermostat- Specify:Type 17-16 1 Weather Resistant Vibration,: Isolation Pads "' • : 1 Year 1 Visit Maintenance Agreement 0 6 Year Extended VVarrairty 010 Year ecteriCad Warranty Refrigerant Capper Suction Una with insirlatitikSbte:77 Length ofRun Newer Existing Copper': 0 Refrigt eran Line Ccifrer OTHER • 0Smoke Detettor-.Btisting/New 1 • ' • • .D Straps . ..E1traneiGerita Uft • BrtenciSlaii •• IllaNesi Slab ,• Labor Needed WARRANTIES' 1 Year Warranty by All Year Cooling on work performed, and ; Manufacturer's Warranties manufacturer's warranty on equipment unless otherwise stated below: • • Compressorf- -Years u . • . • • • I• Conden.ser....-- rears Labor provided by seller Instele period Menday through Rundei. • • • • • • • Evap. .Years ::.:.INVESTMENTBREAi(DOWN -- Subtotal Permit Utility Rebate Man. Rebate Mtsc Credits $ $ $ 150 's $ $ 37 $ Total Investments $ $ • $ • • • Balance Due $ 4 I $ . 1 TERM Any finenclag 'must libereengad24 kens prior iostartini any work. Balance Due to T Upon Completion .// AHYLd Ing Rep. License 9 CAM: • • • E1506X, U16711.1:38160413;. ERR0IZ903 ' • • • .114sa a.1--e. Labor Years Parts • Years I LSOF-WORK-.RERF OR KA to4rJ Fimn of Pa;i■;• . Cheek CC Flamm - • • • SEE REVERSE FORTERMSAND CONDfrIONS • • Miami Shores Village Building Department 10050 N.E,2nd Avenue Miami Shores Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done):, 19 7 1I E HID S City: Miami Shores Village County: Miami Dade Zip Code: 3 3 I 3 i ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO Ei ARHI Sheet Attached: YES Er/NO ❑ Contract Attached: YES Eri UNIT BEING REPLACED DATA NEW UNIT ILh MANUFACTURER altaainAJ P$Ht,- 05 AHU or PKG. UNIT MODEL # kB t Pos St 1 ie.-I '( ° at) 0 COND. UNIT, MODEL # I4AJ,i(oo 10 KW HEAT 10 5 NOM TONS 5 • AHU 5-b CU 50 PKG 1; M.C.A AHU 5o CU 5) PKG AHU G, CU (o, PKG 2 M.O.P AHU loo CU ., PKG AHU CU PKG 3, VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / 114 g pki EERISEER I din YES REPLACING DUCTS YES 0 REPLACING THERMOSTAT E NO YES ' • NEW 4°CONCRETE SLAB YES 0) YES .; NEW ROOF STAND YES 0 YES or, NEW RETURN PLENUM BOX YES 0) Minimum Circuit Ampacity (tire Size): to /a. Maximum Overcurrent Protection (Fuse/Breaker Size): foo Voltage of Circuit (208/240/480): Size Disconnecting Means: (old :ontractor's Company Name: tl tate Certificate - •'station N. CA signature iK1 Mkt 1PF • Phone: qS14--50‘ Certificate of Competency N. .ItrnCs1 I (Qualifier's slit tore and Date: 6 - I - ( I AHRI Certified Reference Number: 3620618 Date: 5/31/2011 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 14AJM60 Indoor Unit Model Number: RBHP -25 +RCHL -60A1 Manufacturer: RHEEM MANUFACTURING COMPANY Trade /Brand name: RHEEM 14AJM SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 54500 EER Rating (Cooling): 11.50 SEER Rating (Cooling): 14.00 Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, whtch indicates an involuntary rerate. • DISCLAIMER AHRI does not endorse the products) ILsted on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the products►, orthe unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and co figurations listed In the directory at www.ahridirecto y.ort. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHR!. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in park be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, In any form or manner or by any means. except for the user's individual, personal and confidential reference. , CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridlrectorg.org, Air- Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ' no Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which Is listed below. 02011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129513501100046078 Miami Shores village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): 119 7 Nl E / W City: Miami Shores Village County: Miami Dade Zip Code: 33 1 3 ? ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO 2 ARHI Sheet Attached: YES [/NO ❑ Contract Attached: YES [ UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER 01011, (2-6Rt, -as AHU ar PKG. UNIT MODEL # kf.311P0S3 -ti takel - l7tgo COND. UNIT, MODEL # I+! A-.i i (po 10 KW HEAT I 0 6 NOM TONS 5 AHU 5b CU 50 PKG 1' M.C.A AHU 5® CU 5b PKG AHU , s CU (oa PKG 2' M.O.P AHU too CU ,. PKG AHU CU PKG 3; VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / 1 14 .S ' EERISEER )t YES REPLACING DUCTS YES ern) �V© REPLACING THERMOSTAT NO tES • . NEW 4 "CONCRETE SLAB YES , a)) YES 41 • NEW ROOF STAND YES CWO) YES cal, NEW RETURN PLENUM BOX YES (NO-D Minimum Circuit Ampacity (Wire Size): (01 a. Maximum Overcurrent Protection (FuselBreaker Size): loo . Voltage of Circuit (20812401480): 3 Size Disconnecting Means: (oo :ontractor's Company Name: A 1I car tha Phone: 6194-Slot. - 44' tate Certificate or istration N. C4 l Certificate of Competency N. (_rACSi I k Waterweretarn ter.ViVetrittar WW1 r WPM% tramaiiire „ :Wes getretWerrearernWalin‘Attat'aXWOrtWitieitiAAWlentairMair el 13 AHRI Certified Reference Number: 3620618 Date: 5/31/2011 Product: Split System: Air-Cooled Condensing Unit,. Coil with Blower Outdoor Unit Model Number: 14AJM60 Indoor Unit Model Number: RBHP-25+RCHL-60A1 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 14AJM SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 54500 EER Rating (Cooling): 11.50 • . . -... SEER Rating (Cooling): 14.00 Ratings followed by an asterisk () indicate a voluntary rerate of previously published data, unless accompanied with a WAS, wh Ich indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no rapresentadons, warranties or guarantees as to, and assumes no responsibility for, the product(s) fisted on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations fisted in the directory at wwiaartrwitirectowy.m. A TERMS AND CONDITIONS - This Certificate and tts contents are proprietary products of AHRL This Cartifrcate shall only be used for indiid tifi ual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise udlized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. , CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ehridirectory;om, click on "Vet* Cottirleate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which is listed below. ©2011 Air-Conditioning, Heating, and Refrigeration Institute :nird.ctztztnrotatinogn,ILeati4 race, CERTIFICATE NO.: 129513501100046078 L. t4; p IWASAMSIL.WZROMMTAM..',".• -